Update on thin vs thick micro-strip detector studies G. Casse, P. Dervan, D. Forshaw, A. Greenall, I. Tsurin, T. Huse, 1 G. Casse,20th RD50 Workshop, Bari 31/05- 02/06 2012

Update on thin vs thick micro-strip detector studies

  • Upload
    zayit

  • View
    34

  • Download
    0

Embed Size (px)

DESCRIPTION

Update on thin vs thick micro-strip detector studies. G. Casse, P. Dervan, D. Forshaw, A. Greenall , I. Tsurin , T. Huse , . CONTEXT:. - PowerPoint PPT Presentation

Citation preview

Page 1: Update on thin  vs  thick micro-strip detector studies

Update on thin vs thick micro-strip detector studies

G. Casse, P. Dervan, D. Forshaw, A. Greenall, I. Tsurin, T. Huse,

1G. Casse,20th RD50 Workshop, Bari 31/05-02/06 2012

Page 2: Update on thin  vs  thick micro-strip detector studies

CONTEXT:The choice of thin silicon sensors seems to meet the requirements for lowering the material budget of the vertex detectors, providing at the same time accrued radiation hardness (at very high doses). But, how thin can they be? This certainly depends on the application and the characteristics of the detector system.Microstrip detectors are not the configuration where reduced thickness can be pushed to the lower limits. Nonetheless studying the radiation hardness properties of thin microstrip sensors gives valuable indication on the change of their properties.We show here the CC(V) measurements of 100, 140 and 300 mm thick after irradiation to doses of 2E16 neq cm-2.

2G. Casse,20th RD50 Workshop, Bari 31/05-02/06 2012

Irradiation with reactor neutrons performed at the JSI reactor, usual thanks to V. Cindro et al.

Page 3: Update on thin  vs  thick micro-strip detector studies

300µm

3G. Casse,20th RD50 Workshop, Bari 31/05-02/06 2012

Degradation of the CC(V) with neutron fluence for the 300mm thick sensors.

Page 4: Update on thin  vs  thick micro-strip detector studies

140µm

4G. Casse,20th RD50 Workshop, Bari 31/05-02/06 2012

Degradation of the CC(V) with neutron fluence for the 140mm thick sensors. Likely mislabelling of one sensor, it looks like the irradiation dose of 5E15 neqcm-2 is missing.

Page 5: Update on thin  vs  thick micro-strip detector studies

100µm

5G. Casse,20th RD50 Workshop, Bari 31/05-02/06 2012

Degradation of the CC(V) with neutron fluence for the 100mm thick sensors. Likely mislabelling of one sensor, it looks like the irradiation dose of 5E15 neqcm-2 is missing.

Page 6: Update on thin  vs  thick micro-strip detector studies

2x1015 neq cm-2

6G. Casse,20th RD50 Workshop, Bari 31/05-02/06 2012

Comparison of the CC(V) after this dose for the 100, 140 and 300mm thick sensors. Collected charge similar at low voltages.

Page 7: Update on thin  vs  thick micro-strip detector studies

7G. Casse,20th RD50 Workshop, Bari 31/05-02/06 2012

1x1016 neq cm-2 Comparison of the CC(V) after this dose for the 100, 140 and 300mm thick sensors. Thinner sensor exhibit better collected charge at same applied bias voltage.

Page 8: Update on thin  vs  thick micro-strip detector studies

8G. Casse,20th RD50 Workshop, Bari 31/05-02/06 2012

2x1016 neq cm-2 Comparison of the CC(V) after this dose for the 100, 140 and 300mm thick sensors. Thinner sensor exhibit better collected charge at same applied bias voltage.

Page 9: Update on thin  vs  thick micro-strip detector studies

9G. Casse,20th RD50 Workshop, Bari 31/05-02/06 2012

Degradation 300µm

Page 10: Update on thin  vs  thick micro-strip detector studies

10G. Casse,20th RD50 Workshop, Bari 31/05-02/06 2012

CC(V)

Degradation 140µm

Page 11: Update on thin  vs  thick micro-strip detector studies

11G. Casse,20th RD50 Workshop, Bari 31/05-02/06 2012

CC(V)

Degradation 100µm

Page 12: Update on thin  vs  thick micro-strip detector studies

12G. Casse,20th RD50 Workshop, Bari 31/05-02/06 2012

1000 V

Degradation all thicknesses600 V

Page 13: Update on thin  vs  thick micro-strip detector studies

G. Casse,20th RD50 Workshop, Bari 31/05-02/06 201213

CONCLUSIONSThin sensors deliver higher charge collection than standard (300mm) silicon

sensors after about 2E15 neq cm-2. The thinnest 100mm sensors also show an advantage towards the 140mm thick after the highest dose (2E15 neq cm-2).

We tried 50mm thick devices but the signal is hardly resolvable from the noise tail with microstrip electronics.

We would like to explore the effect of proton irradiation and of higher doses. It is also possible that 75mm thick devices can be usable with pour readout systems (typically Alibava, sct128...).