Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
REGLASSED VESSEL
Vessel Type / Size REACTOR 125 GALLONS
ASSEMBLY
Ref. Stock Number 216264
Vessel Serial No. 34069
National Board No. 4710
ATTACHED DOCUMENTS
1. Form R-1 Report of Repair 2. Manufacturer’s Data Report U-1 Form 3. Copy of the Mfg. Nameplate
Repair & Reglass Nameplate
4. Final inspection report 5. Plug chart 6. Report for function verification
7. Reference drawing (216264 Rev. A)
If you have any questions on Service or Inquiries on our equipment contact
UGE @ Phone # (609) 586-8004 or Fax # (609) 586-8002.
UNIVERSAL GLASTEEL EQUIPMENT
17A Marlen Drive Hamilton New Jersey 08691
Stock #216264
Stock #216264
Top head nameplates
QUALITY CONTROL DEPARTMENT
FINAL INSPECTION REPORT
Vessel Type / Size REACTOR 125 GALLONS
Ref. Stock number 216264 Vessel Serial no. 34069 National Board no. 4710
I hereby certify the above equipment has been re-glassed and conforms to UGE-R’s Quality Specification QS-001-99 and the results are:
Visual inspection Satisfactory
Glass thickness 0.047-0.071 inches (within specification)
Plugs None
Spark tested (20 Kv during fabrication & 6 Kv before packing)
Satisfactory
Quality Assurance Supervisor July 30, 2014 Rodica Robotin
UGE ROMANIA
PLUG CHART
Stock No. 216264 Serial No. 34069 NB Number 4710
CUSTOMER: CUSTOMER P. O: #
ITEM: # REACTOR 125 GALLONS
SIZE & TYPE
PLUGS # 1 NONE # 2
COMMENTS
SPARK TESTED
( at 20 Kv during fabrication & 6 Kv before packing )
Satisfactory spark tested the vessel and its
accessories.
PATCH OR SLEEVE: NONE
INSPECTION Quality Control Inspector DATE: July 30, 2014 Inspected by Quality Assurance Supervisor DATE: July 30, 2014 Approved by
Repaired by UGE Romania
Glass lined Reactor 125 GAL # 216264 Report for Function Verification
Page 1 / 1
Test – Drive system Vessel empty with water
Remarks : The drive system has been tested in functioning for 2 hours. The oil pressure in lubricator: 6 bars (87 psi). The seal housing temperature measured after 2 hours functioning was 430C (1100F) max. The drive system sound level during functioning test: 69-72 dB. The system was accepted for operation. UGE – R Representative Date Quality Assurance Supervisor Rodica Robotin June 30, 2014 Signature
Customer’s Representative Date:
Signature --- ---
Conformity The reactor was assembled according with the UGE Romania drawing # 216264 Rev A . Exterior : Painting Blue paint -final coating The reactor 216264, 125 GAL. is in accordance with the order requirements and accepted for delivery.
Remarks : N.A
UGE – R Representative Date Quality Assurance Supervisor
Rodica Robotin July 30, 2014 Signature
Customer’s Representative Date:
Signature --- ---
DRIVE SYSTEM - SPECIAL Mechanical seal with lubricator. Gear drive Special 18:1 Ratio Motor 2 HP, 1735 RPM 230/460/3/60 Hz
x --
x x
3 inches The Actual ground clearance of the agitator. 97 RPM The agitator’s speed. Impeller agitator.