12
SCALABILITY EFFICIENCY RELIABILITY Make in India Company UNINTERRUPTIBLE POWER SUPPLIES Upto 2400 kVA Autometers Alliance Ltd

UNINTERRUPTIBLE POWER SUPPLIES UPS Catalogue.pdf · UNINTERRUPTIBLE POWER SUPPLIES Upto 2400 kVA Autometers Alliance Ltd. Autometers Alliance Ltd manufacturing online Pegasus UPS

  • Upload
    others

  • View
    29

  • Download
    2

Embed Size (px)

Citation preview

Page 1: UNINTERRUPTIBLE POWER SUPPLIES UPS Catalogue.pdf · UNINTERRUPTIBLE POWER SUPPLIES Upto 2400 kVA Autometers Alliance Ltd. Autometers Alliance Ltd manufacturing online Pegasus UPS

SCALABILITY EFFICIENCY RELIABILITY Make in India

Company

UNINTERRUPTIBLEPOWER SUPPLIES

Upto 2400 kVA

Autometers Alliance Ltd

Page 2: UNINTERRUPTIBLE POWER SUPPLIES UPS Catalogue.pdf · UNINTERRUPTIBLE POWER SUPPLIES Upto 2400 kVA Autometers Alliance Ltd. Autometers Alliance Ltd manufacturing online Pegasus UPS

Autometers Alliance Ltd

manufacturing online Pegasus UPS systems upto 2400 kVA (8×300 kVA) based on European

Technology sourced from Powertronix S.p.A, Italy and adapted to Indian operating conditions.

Autometers Alliance Ltd offers MODULAR and STAND ALONE systems designed as GREEN

POWER SOLUTION, a boon for the company's expanding list of satisfied customers.

Powertronix S.p.A. Italy is Europe's leading designer and manufacturer of online UPS systems

for over 20 years having presence in six continents across the globe. Based on its research

philosophy, strong design elements and strict testing procedures, Powertronix delivers high

quality and reliable products conforming to International Standards as well as meeting regional

specifications. Powertronix continuously supports Autometers Alliance Ltd in technology

upgradation and customized application endeavors.

ranks amongst the premier UPS manufacturers in the country,

ABOUT PEGASUS UPS

1

PRODUCT RANGE

PRODUCT SERIES CONFIGURATION RATING

3Ø 3Ø INPUT - OUTPUT

3Ø INPUT - 1Ø OUTPUT

3Ø INPUT 1Ø I - OUTPUT

3Ø 3ØINPUT - OUTPUT

3Ø 3Ø INPUT - OUTPUT

ALPHA 31 SERIES

PGS-31 SERIES

ALPHA 33 SERIES

GAMMA SERIES

ALPHA RM SERIES

BETA SERIES 3Ø 3Ø INPUT - OUTPUT

10-500 kVA *

10-40 kVA

10-60 kVA

10-400 kVA*

10-600 kVA *

60-300 kVA*

*Parallelable systems

Customised UPS solutions & / or client ‘Load Analysis’ offered on demand

Page 3: UNINTERRUPTIBLE POWER SUPPLIES UPS Catalogue.pdf · UNINTERRUPTIBLE POWER SUPPLIES Upto 2400 kVA Autometers Alliance Ltd. Autometers Alliance Ltd manufacturing online Pegasus UPS

2

SALIENT FEATURESFPGA (DSP) BASED DOUBLE CONVERSION TOPOLOGY

ACTIVE POWER FACTOR CORRECTION AT UPS INPUT

HIGH FREQUENCY PWM BASED INVERTER USING IGBTS

PARALLEL REDUNDANCY

AUTO RE-TRANSFER STATIC SWITCH

ENERGY SAVING MODE

HIGH POWER DENSITY

INDEPENDENT LCD

FLEXIBILITY / UPGRADABILITY

At input stage AC supply is converted to controlled DC and in second stage DC is converted to controlled AC which is used to support the critical loads. Due to double conversion the load is completely protected against spikes, surges and brownouts. Use of FPGA (DSP) ensures low component count and reliability of the circuit.

At input stage, conversion from AC to controlled DC is achieved through high frequency PWM based Converter using IGBTs. This technology offers following benefits to the user.

• Input power factor >0.99

• Very low input current distortion (<3%), input current waveform similar to pure sinewave. No harmonics will be reflected back to mains, thus no pollution of the input mains

• UPS can operate with almost same capacity Generator

• Auto correction for input phase sequence reversal

• Reduced size of cabling and switchgear at the input stage

Conversion from DC to controlled and pollution free AC is achieved through high frequency PWM based Inverter using IGBTs with instantaneous sinewave control. The technology offers following benefits to the users.

• High efficiency

• Low noise

• Compact size

• Faster transient response

The Alpha, Beta & Gamma series of UPS systems can be used in parallel configuration. Paralleling can be done for the purpose of either redundancy or capacity enhancement. These systems can be configured in hot stand-by, 100% parallel redundant and N+1 redundant mode.

These UPS systems have a unique feature of re-transferring load automatically back to inverter as long as inverter is healthy and the load is within the capacity of the UPS.

This feature is very helpful for starting of loads, which draw starting in-rush current more than capacity of the UPS. The UPS goes to bypass on sensing over load and comes back on inverter supply automatically once the load current is settled to normal level. In addition to static switch, manual bypass switch is also provided for easy maintenance.

The UPS can operate in line-interactive mode simply by changing a jumper. The efficiency in this mode is up tp 98% leading to a big energy saving in applications where UPS is used as standby power source.

The Alpha RM series of UPS provides the most compact footprint by having a best in class Power Density of 409

2KW/m .

In RM Series each Power Module has independent LCD which displays Status and Alarms in real time.

a) Inherent N+X Redundancy

b) Hot swappable power module, bypass and monitoring module

c) Additional charging module can be added for longer back-up applications.

Page 4: UNINTERRUPTIBLE POWER SUPPLIES UPS Catalogue.pdf · UNINTERRUPTIBLE POWER SUPPLIES Upto 2400 kVA Autometers Alliance Ltd. Autometers Alliance Ltd manufacturing online Pegasus UPS

3

SMART SLEEP

This function enables some power modules to go to sleep when load is

relatively low, improving the efficiency of the remaining power modules.

The modules can also be made to work in a rotation mode by customer.

PHANTOM LOADING

This is an advanced function which can test the UPS under different load

situations without real load, saving more than 90% energy. Simulation of

load can be done for load testing at factory as well as at site.

UPS MANAGEMENT SOFTWAREUPS-Management Software is a client/server application for local, global

networks and also for single workstation. The server module of the UPS

Management Software is called UPSMAN, which communicates with the

UPS in RS232 mode via cable, or through the network, by a SNMP

adapter.

BENEFITS OF FPGA APPROACH

Scalability / Expandability Unlimited potential for growth & flexibility

Parallel processing Single or multi-systems on one chip

Deterministic Design Won't impact the part of the design already in place

Limitless Performance Out performs traditional DSP or Micro controller

Bus-bridging & peripheral functions

Allows high level of system integration

State-of-art Ready to use, re-configurable in the field

THE FPGA ADVANTAGE

Core functions of PEGASUS UPS are controlled by state-of-art high

performance FPGA based DSP, ensures multiple parallel processing and

expandability.

Comparison of processing 256 data samples by DSP & FPGA is illustrated

in Figure 1. Traditional DSP or microcontroller is processing sequentially,

whereas FPGA is processing simultaneously by means of dedicated

registers & multipliers, hence FPGA can be configured for faster response.

+

256-tap Filter Example

Conventional DSP Processor - Serial implementation

FPGA - Fully parallel implementation

Data In

C2 C3 C4 C5 C255

256 operations

in 1 clock cycle

Reg

XX XXX X

Data Out

Figure 1: FPGAs Parallel approach to DSP enables

Higher Computational Throughput

X

Data In

256 loops

needed

to process

samples

Data Out

Reg

MAC Unit

+

Coefficients

C0 C1X

Reg Reg Reg Reg Reg

The FPGA Advantage

UPS Management Software

Phantom Loading

Smart Sleep

Page 5: UNINTERRUPTIBLE POWER SUPPLIES UPS Catalogue.pdf · UNINTERRUPTIBLE POWER SUPPLIES Upto 2400 kVA Autometers Alliance Ltd. Autometers Alliance Ltd manufacturing online Pegasus UPS

3Ø Input - 1Ø Output

ALPHA 31 SERIES

10-40 kVA

Standard Features :

• Wide I ange

• High Input Power Factor

• Protection against Over Voltage, Short Circuit and Over Temperature

• Auto Fan Speed Adjustment

• LCD Display Monitoring all the operational status

nput Voltage R

Optional Features :

• SNMP for Remote Monitoring

• Dry Contacts

• Parallel Kit

• AS/400 Interface

• Battery Cold Start

4

ENVIRONMENTAL CONDITIONS

OUT PUTVoltage

Voltage Regulation

Total Harmonic Distortion

Power Factor

Crest Factor

Overload (inverter Mode)

DC LINK

Battery Voltage

Efficiency (Overall)

Efficiency (Inverter)

Efficiency (Eco Mode)

Display

Interface

Degree of Protection

Audible Noise

220/230/240 (Selectable)

1.50%

1% Linear Load, 5% Non Linear Load

0.9

3:1

110% for 10 min, 130% for 1 minute150% for 30 second

192VDC ±240VDC

95%93.50%

95%92%

98%

LED + LCD

RS232,RS485,USB

RS232,EPO

IP20

65dB

Operating Temperature

Storage Temperature -20°C to 70°C

Relative Humidity

0-40°C

0-95% (Non - Condensing)

PHYSICAL PARAMETERS

Dimensions(WxDxH) in mm

600x980x950

250x562x710

250x562x650

Approx.Weight (in Kg.) 170342725

53dB@<70% Load, 66dB@>70 % Load

1000 Meters without deratingMaximum Altitude Above Sea Level

Ratings (kVA/KW)

INPUTNominal Voltage

Voltage Range

Current Distortion

Frequency Range

380/400/415 V AC (Selectable)

320 to 480V@100% Load

4%

Power Factor 0.99 0.95

40Hz - 70Hz

40/3620/1815/13.510/9

Frequency 50 or 60 Hz (Selectable)

SYSTEM

Page 6: UNINTERRUPTIBLE POWER SUPPLIES UPS Catalogue.pdf · UNINTERRUPTIBLE POWER SUPPLIES Upto 2400 kVA Autometers Alliance Ltd. Autometers Alliance Ltd manufacturing online Pegasus UPS

PGS-31 SERIES 3Ø Input - 1Ø Output

10-60 kVA

5

200 250 300 350 425 450380Approx. Weight (kg.)

GENERAL

INPUT

Ratings (kVA/KW) 15/13.5 20/18 30/27 40/36 50/45 60/54

Nominal Voltage 3ø, 380 / 400 / 415V

Voltage Range 350 to 460

Frequency 50 or 60 Hz (Selectable)

Frequency Range 40 to 60Hz

Current Distortion <9% (Optional)

Power Factor 0.99 (Optional)

Battery Voltage

± 1%

< ± 1%

Voltage Tolerance

Voltage Ripple

384 Volts

Switching TimeInverter Failure : 2 ms

Other Modes : 0

STATIC BYPASS

Voltage Regulation

Overload

Voltage Distortion

OUTPUT

Nominal Voltage

50 or 60 Hz (Selectable)

0.9

Frequency

Power Factor

220V/230V/240V

< 3% at Linear Load

125% for 10 Minutes

Crest Factor 3:1

EfficiencyInverter : 93%

Overall : 91%

ENVIRONMENTAL CONDITIONOperating Temperature

-20°C to +70°C (Not for Batteries)

95% Non-condensing

Storage Temperature

Relative Humidity

0-40°C

1000 Meters without deratingMaximum Altitude Above Sea Level

PHYSICAL

Dimensions (WxDxH) mm

< 60dBA

Forced AirCooling

Audible noise at 1 Mtr.

Ingress protection IP – 21

10/9

390×910×630 530×920×860 700x740x1800

Static : ±1%

Dynamic : ± 5%

DC LINK

Standard Features :

• High Frequency PWM Using IGBTs• Inbuilt Isolation Transformer• Auto Re -Ttransfer Static Switch• Manual Bypass• Extended Battery Back-Up

Optional Features :

• SNMP for Remote Monitoring

• Active Power Factor Correction

• Software for Auto Shutdown

• Potential Free Contacts for Remote

Indications & Shutdown

• Management Software

Page 7: UNINTERRUPTIBLE POWER SUPPLIES UPS Catalogue.pdf · UNINTERRUPTIBLE POWER SUPPLIES Upto 2400 kVA Autometers Alliance Ltd. Autometers Alliance Ltd manufacturing online Pegasus UPS

3Ø Input - 3Ø Output

GAMMA SERIES

10-400 kVA

6

Overload

50 or 60 Hz (Selectable)Frequency

0.9Power Factor

125% for 10 Minutes

Crest Factor 3:1

EfficiencyInverter : 94%Overall : 92%

OUTPUT

INPUT

Ratings (kVA/KW)

Nominal Voltage

Voltage Range 350 to 460

Frequency 50 or 60 Hz (Selectable)

Frequency Variation 40 to 60Hz

3ø, 380 / 400 / 415V (Selectable)

3ø, 380 / 400 / 415V (Selectable)

10 - 400 kVA

Nominal Voltage

Voltage Regulation Balanced Load ±1%Unbalanced Load ± 5%

Phase Displacement Balanced Load 120° ± 1°Unbalanced Load 120° ± 3°

Voltage Distortion < 3% at Linear Load

Frequency Synchronization Range

±1%, ±2%, ±5%, ±10% (Selectable)

DC LINKBattery Voltage

± 1%

< ± 1%

Voltage Regulation

Voltage Ripple

384 Volts

Switching Time Inverter Failure : 2 ms

Other Modes : 0

STATIC BYPASS

ENVIRONMENTAL CONDITION

GENERAL

Operating Temperature

-20°C to +70°C (Not for Batteries)

95% Non - Condensing

Storage Temperature

Relative Humidity

0-40°C

1000 Meters without deratingMaximum Altitude Above Sea Level

Ingress Protection IP – 20

Forced AirCooling

<45 <45 <50 <50

440 x 900 x 1015

<50 <50 <50 <55 <55

500 x 1025 x 1075 700 x 725 x 1800

10/9

180 205 250 300 325 385 610 700355

15/13.5 20/18 30/27 40/36 50/45 60/64 80/72 100/90

<65

900

120/108

<65

1100

160/144

<65 <70 <70

1000 x 905 x 1965 1600 x 950 x 2100

1200 1800 1850

200/180 300/270 400/360

Weight (kg)

Dimensionsin mm (WxDxH)

kVA/KW Ratings

Noise Levelin db

Standard Features :

• High Frequency PWM Using IGBTs• Inbuilt Isolation Transformer• Auto Re-Transfer Static Switch• Energy Saving Mode• Parallel Redundancy

Optional Features :

• SNMP for Remote Monitoring

• Management Software

• Remote Monitor for Alarms / Indications

• Remote Emergency Power Off

• Potential Free Contacts for Remote Indications

• Voltage Stabiliser in Bypass Line

• Battery Management System

Page 8: UNINTERRUPTIBLE POWER SUPPLIES UPS Catalogue.pdf · UNINTERRUPTIBLE POWER SUPPLIES Upto 2400 kVA Autometers Alliance Ltd. Autometers Alliance Ltd manufacturing online Pegasus UPS

BETA SERIES 3Ø Input - 3Ø Output

60-300 kVA

7

410 x 835 x 1510 1000 x 900 x 2000 1600 x 950 x 2100

60/54

425

<50 <55 <60

580 650 900 1080 1200 1750 1850

80/72 100/90 120/108 160/144 200/180 250/225 300/270

Weight (kg)

Dimensionsin mm (WxDxH)

kVA / KWRatings

Noise Levelin db

Standard Features :

• Active Power Factor Correction at UPS Input• FPGA (DSP) Based Double Conversion Topology• Parallel redundancy• Energy Saving Mode

Optional Features :

• SNMP for Remote Monitoring.

• Isolation Transformer at UPS Input and Output

• Management Software

• Remote Monitor for Alarms/ Indications

• Remote Emergency Power Off

• Potential Free Contacts for Remote Indications

• Voltage Stabiliser in Bypass Line

• Battery Management System

50 or 60 Hz (Selectable)Frequency

0.9Power Factor

OUTPUT

Nominal Voltage

Voltage Regulation Static : ±1% Dynamic : ± 5%

380 / 400 / 415 V AC (Three Phase+N)

Parallelability Upto 8 Systems

Overload 125% for 10 Minutes

Crest Factor 3:1

EfficiencyInverter : 95%

Overall : 93%

Voltage Distortion < 3% at Linear Load

672 Volts

DC LINKBattery Voltage

Switching Time Inverter Failure : 2 ms

Other Modes : 0

STATIC BYPASS

ENVIRONMENTAL CONDITION

GENERAL

Operating Temperature

-20°C to +70°C (Not for Batteries)

95% Non - Condensing

Storage Temperature

Relative Humidity

0-40°C

1000 Meters without deratingMaximum Altitude Above Sea Level

Ingress Protection IP – 20

0.99Power Factor

Current Distortion <3%

380 / 400 / 415 V AC (Three Phase+N)

INPUT

Ratings (kVA/KW)

Nominal Voltage

Voltage Range

Frequency 50 or 60 Hz (Selectable)

Frequency Range 40Hz to 60Hz

60 - 300 kVA

330 to 480

Page 9: UNINTERRUPTIBLE POWER SUPPLIES UPS Catalogue.pdf · UNINTERRUPTIBLE POWER SUPPLIES Upto 2400 kVA Autometers Alliance Ltd. Autometers Alliance Ltd manufacturing online Pegasus UPS

ALPHA 33 SERIES 3Ø Input - 3Ø Output

10-500 kVA

8

Standard Features :• High Efficiency upto 96%• High Input PF>0.99, Input current THDI<3%• Multi Protections : Over Temperature Protection with 8 Sensors,

Overload, Battery Under Voltage, Fan Failure, Short - Circuit• Battery Cold Start• Modular Design of Subsystem, Convenient for Field Maintenance• Intelligent Battery Management with Smart Charging Control• High Power Density

Input CurrentDistortion

<4%

<4%

<3%

<3%

<3%

<3%

<3%

<3%

<3%

<3%

<3%

<3%

<3%

<3%

<3%

<3%

RatingkVA/KW

10/10

15/15

20/18

30/27

40/36

60/54

80/72

90/81

100/90

120/108

150/135

200/180

250/225

300/270

400/360

500/450

System Efficiency

Over all Inverter

95%

95%

95%

95%

96%

96%

96%

96%

96%

96%

96%

96%

96%

95.50%

95.50%

95.50%

94.50%

94.50%

95%

95%

96%

96%

96%

96%

96%

96%

96%

96%

96%

95%

95%

95%

Output PowerFactor

1

1

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

Weight(Kg.)

DimensionWxDxH (mm) Noise

31

31

50

52

61

170

210

210

231

266

305

350

445

490

810

900

250x660x530

250x660x530

250x680x770

250x680x770

250x836x770

600x980x950

600x980x1150

600x980x1150

600x980x1400

600x980x1400

600x960x1600

600x960x1600

600x960x2000

600x960x2000

1300x1100x2000

1300x1100x2000

<55dB

68dB

72dB

DC LINK

Voltage

50 Hz or 60Hz (Selectable)

40-70Hz

Technology Double Conversion True Online Topology

Frequency range

Frequency

OUTPUT

Voltage Regulation 1% for Balanced Load, 1.5% for Unbalanced Load.

Voltage Distortion <1% (Linear Load) <5.5% (Non-Linear Load)

110% for 60 Minutes, 125% for 10 Minutes,150% for 1 Minutes.

± 240 VDCBattery Voltage

SYSTEM

>0.99Power Factor

INPUT Voltage

Voltage Range

10-500 kVARatings (kVA/KW)

304-478 V AC

3Ph+N+PE 380 / 400 / 415 V (Line-Line)

380 / 400 / 415 V (Line-Line Nominal), Selectable at Site

Display LCD & LED

Charging Current

Low Battery Cut-off

20% of System Power

1.7V/ Cell

Overload Capacity

±0.01% (in Free-Running Mode)Frequency Variation

Degree of Protection IP20

Interface : Standard RS-232, RS-485, Dual Input Kit

Temperature range of Operation 0 – 40°C

Relative Humidity 0 – 95% (Non - Condensing)

Interface : Optional SNMP, Dry Contacts

Page 10: UNINTERRUPTIBLE POWER SUPPLIES UPS Catalogue.pdf · UNINTERRUPTIBLE POWER SUPPLIES Upto 2400 kVA Autometers Alliance Ltd. Autometers Alliance Ltd manufacturing online Pegasus UPS

3ØInput - 3Ø Output

ALPHA RMS (RACK-MOUNTED SERIES)

10-600 kVA

9

Note:

*

10KW module can be set as 1/1, 3/1, 3/3 and 1/3 Power connection. 15KW onwards modules can only be set as 3/3 connection. For 10KW&15KW Modules input current distortion is <4%.

Frequency

Frequency Variation(in Free-Running Mode)

Phase Tolerance

Crest Factor

Overload

50Hz or 60Hz (Selectable)

±0.01%

120°±0.5° (Balanced and Unbalanced Load)

3:1

110%,60 minutes

125%,10 minutes

150%, 1 minute

Battery Voltage

Charge Power

Low Battery Cut-Off

±240VDC

20% of System Power

1.7V/ Cell

DC LINK

SYSTEMOverall Efficiency in Normal Mode

95%

Efficiency in ECO Mode

99%

Efficiency in Battery Mode 94.50%

Display 7” Touch Colour LCD & LED

Degree of Protection IP20

Interface : Standard RS-232, RS-485, EPO, Dry Contacts

Temperature Range of Operation 0 – 45°C

Relative Humidity 0 – 95% (Non-Condensing)

Audible Noise (1 Meter away)

56dB(One Module)

Interface : Optional SNMP

Voltage

Technology Double Conversion True Online Topology

40-70HzFrequency Range

OUTPUT

Voltage Distortion<1% (linear load) <5.5% (Non-Linear Load)

>0.99Power Factor

INPUT Phase

Voltage Range

10kVA - 600kVARatings (kVA/KW)

276-480V

3Ph+N+PE 380 / 400 / 415 V (Line-Line)

380 / 400 / 415 V (Line-Line Nominal)

Input Current Distortion <3%*

Voltage Regulation 1.50%

Standard Features :• Modular design convenient for field maintenance, upgradation and redundancy • High power density • Independent LCD• Isolated Air Flow• Flexibility / Scalability• Waveform Recording• Smart Sleep• Phantom Loading• Programmable Potential Free Contacts

Bypass & Monitoring Module

Power Module

Man-Machine Interface

Page 11: UNINTERRUPTIBLE POWER SUPPLIES UPS Catalogue.pdf · UNINTERRUPTIBLE POWER SUPPLIES Upto 2400 kVA Autometers Alliance Ltd. Autometers Alliance Ltd manufacturing online Pegasus UPS

3Ø Input - 3Ø Output

ALPHA RMS (RACK-MOUNTED SERIES)

10-600 kVA

Cabinet SizeWxDxH (mm)

485X697X398

485X751X575

485X697X575

485X751X1033

485X697X398

485X751X575

485X751X1033

600X900X1100

600X900X1600

600X900X2000

600X1100X1600

600X1100X2000

2000X1050X2000

600X1100X1600

600X1100X2000

2000X1050X2000

1300X1100X2000

20kVA/20KW

30kVA/30KW

60kVA/60KW

30kVA/30KW

45kVA/45KW

90kVA/90KW

120kVA/108KW

200kVA/180KW

150kVA/150KW

250kVA/250KW

500kVA/500KW

40kVA/40KW

180kVA/162KW

300kVA/270KW

600kVA/540KW

400kVA/400KW

500kVA/450KW

Maximum kVARating

ModuleRating

(kVA/KW)Model

RM020/10X

RM030/10X

RM040/10X

RM060/10X

RM030/15X

RM090/15X

RM045/15X

RM060/20

RM120/20

RM200/20

RM150/25X

RM250/25X

RM500/25X

RM180/30X

RM300/30X

RM600/30X

RM400/40X

RM500/50X

ModuleWeight(Kg.)

15.3

15.5

22

32

34

44

45

Module SizeWxDxH (mm)

436X590X85 (2U)

440X590X134 (3U)

460X790X134 (3U)

510X700X178 (4U)

CabinetWeight(Kg.)

42

51

55

85

42

55

85

105

145

179

165

220

660

165

220

660

900

10

20

10

10

10

20

2

3

3

3

4

6

6

6

10

2

6

6

MaximumNo.of

Modules

10/10

10/10

10/10

10/10

15/15

15/15

15/15

20/18

20/18

20/18

25/25

25/25

25/25

30/27

30/27

30/27

40/40

50/45

60kVA/54KW

ISOLATED AIR FLOW

The PCB Boards and Heat sinks are mounted on two different layers which ensures satisfactory performance of the UPS even in dusty environment.

CRITICAL WAVEFORM RECORDINGUPS can record the data of the critical parameters automatically when faults occurs. The recorded wave forms and data can be utilised for fault analysis later on.

Page 12: UNINTERRUPTIBLE POWER SUPPLIES UPS Catalogue.pdf · UNINTERRUPTIBLE POWER SUPPLIES Upto 2400 kVA Autometers Alliance Ltd. Autometers Alliance Ltd manufacturing online Pegasus UPS

Autometers Alliance Ltd

DisclaimerAutometers Alliance Ltd reserves the right to introduce changes and improvements made possible by advances in technology and functionality without prior intimation or justification up to the time of both parties endorsing this document with their signatures, or up to the time when the product is actually completed. This document is a 'Quick Reference' and does not mention all features of the equipment.

Corporate Office: C 63, Sector 57, Noida 201 307 (U.P.) India,

Tel.: +91 (0) 120-2583603, 2583545-46, E-mail: [email protected], www.autometers.com

Autometers Alliance Ltd., Noida