UPS, RECTIFIERS & BATTERY CHARGERS, INVERTERS, AC VOLTAGE STABILIZERS, INDUSTRIAL BATTERIES
UPS – Uninterruptible Power SuppliesAll UPS are equipped with IGBT technology, digitalcontrol, integrated static- and manual bypass switches, output isolation transformers, battery test and monitoring, RS232, RS485 and Ethernet SNMP interfaces. All areCE-marked and have a very high MTBF rate.
• S-1200S: 1-ph. IN, 1-ph. OUT, 5 – 10kVA
• S-1200T: 3-ph. IN, 1-ph. OUT, 7,5 – 15kVA
• S-1100: 3-ph. IN, 1-ph. OUT, 20 – 32kVA
• S-4200: 3-ph. IN, 3-ph. OUT, 10 – 15kVA
• S-4100: 3-ph. IN, 3-ph. OUT, 20 – 650kVA
• Powerware 3110 – 9150: 0,3 – 12kVA
RECTIFIERS & BATTERY CHARGERS• BCS: Battery Charger Single phase
Thyristor equipped, with mains isolation transformer,automatic and manual high rate charge with timerOutput: 12 – 220VDC, 10 – 100A
• TPRB: Three Phase Rectifier Battery chargerThyr. equipped, with mains isol. transf., autom. and man.high rate charge with t., battery current limitationOutput: 24 – 220VDC, 50 – 1000A
• BDT: Thyristor Rectifier Charger with Digital ControlThyr. equipped, with mains isol. transf., autom. and man.high rate charge with t., battery current limitation, comm.interfaces, autom. and man. battery test, parallel op.,.... Output: 24 – 220VDC, 50 – 1000A
• BSS / BST: Modular Switch Mode Rectifier ChargerIGBT converter with 20kHz, input PFC, autom. and man.high rate charge with t., battery current limiter, comm.interfaces, parallel op., modular 19“ rack design, ...Output: 24 – 220VDC, 10 – 300A
• SMR, SNP, RKAS: Switch Mode Rectifier ChargerFully equipped Switch Mode Rectifier ChargerOutput: 12 – 220VDC, 2,5 – 200A SMR, SNP, RKAS
BSS, BST
BCS TPRB BDT
S-1200 S-1100 S-4100
Powerware 3110 - 9150
S-4200
UPS, RECTIFIERS & BATTERY CHARGERS, INVERTERS, AC VOLTAGE STABILIZERS, INDUSTRIAL BATTERIES
INVERTERS• IBS, ICS, IJS: 1-phase Inverters
Very high efficiency, 350% overload capability, remotecontrol, output short circuit proof, automatic shut-off atlow DC voltage, stand-by mode, CE mark, ...Input: 12 – 60VDC; Output: 400 – 7000W
• WPS, WPT: 1-ph. and 3-ph. InvertersIGBT-PWM technology, integrated static- and manualbypass switches, low DC shut-down, autom. operationInput: 48 – 220VDC, Output: 5 – 125kVA
• IDS, IDT: 1-ph. and 3-ph. InvertersFully dig. controlled, IGBT-PWM technology, integratedstatic- and manual bypass switches, comm. I/F, ...Input: 48 – 220VDC, Output: 5 – 250kVA
AC VOLTAGE STABILIZERS• Electro-Mechanical Stabilizers RSS....RXFT
Low internal impedance for high surge currents, inputtapings, very high efficiency, spike suppression, ultra-fast response, EMC compatible, CE marked, ...Single- and three phase models from 1,4 to 5470kVAOutput accuracy ± 0,5% or ± 5%
• Solid State Stabilizers SXS....SXTSolid state design, low internal imp. for high surgecurrents, input tapings, very high eff., spike suppression,ultra-fast response, EMC compatible, CE marked, ...Single- and three phase models from 0,34 to 360kVAOutput accuracy ± 0,5% or ± 5%
INDUSTRIAL BATTERIES• SAFT Nickel-Cadmium Batteries
• Pocket PlateSBH, SBM, SBL, Ultima SLM, Ultima.Plus, SPL
• Sintered PBESPH, NCX, SRM, SRX, MRX
• Lead-Acid Batteries
• Valve Regulated Lead Acid (VRLA)OPzV, AGM, Gel, ...
• Vented Lead Acid (VLA)OPzP, OPzS, OGi, GroE
IDS, IDT IBS, ICS, IJS
WPS, WPT
RSS.......RXFT SXS.......SXT
w w w . s t a t r o n . c o m
UPS, RECTIFIERS & BATTERY CHARGERS, INVERTERS, AC VOLTAGE STABILIZERS, INDUSTRIAL BATTERIES
ZSV – Add. Power Supply for Hospital
• ZSV-SIndustrial construction – no modified UPS-system,IGBT technology, galvanic separation of the batterycircuit, parallel operation possible, simple yearlycapacity test, automatic monthly function test, electrical test book, messages and alarms acc. toDIN VDE 0107, batteries incl. 20% capacity reserveacc. DIN VDE 0510 part 2, table 5Output power: 3kVA – 80kVA
• ZSV OP LuxSecure 24V power supply for operation lamps acc. toDIN VDE 0107 (0100 – 710), controlled output voltagefor long lifetime of the OP lamps, ISO-DC-surveillanceof the outgoing circuits, automatic monthly function testelectrical test book, batteries incl. 20% capacity reserveacc. DIN VDE 0510 part 2, table 5Output power: 200W – 4600W
EMERGENCY LIGHTING
• Stand-by lighting
• Escape route signaling
• Anti panic lighting
• High risk task area lighting
• Central Battery Lamps
• Single Battery Lamps
• Datacenter WCentral surveillance, decentral power supplyDatacenter W can monitor up to 1250 lamps.
ZSV-S
ZSV OP Lux
w w w . s t a t r o n . c o m
Datacenter W