3
UPS, RECTIFIERS & BATTERY CHARGERS, INVERTERS, AC VOLTAGE STABILIZERS, INDUSTRIAL BATTERIES UPS – Uninterruptible Power Supplies All UPS are equipped with IGBT technology, digital control, integrated static- and manual bypass switches, output isolation transformers, battery test and monitoring, RS232, RS485 and Ethernet SNMP interfaces. All are CE-marked and have a very high MTBF rate. S-1200S: 1-ph. IN, 1-ph. OUT, 5 – 10kVA S-1200T: 3-ph. IN, 1-ph. OUT, 7,5 – 15kVA S-1100: 3-ph. IN, 1-ph. OUT, 20 – 32kVA S-4200: 3-ph. IN, 3-ph. OUT, 10 – 15kVA S-4100: 3-ph. IN, 3-ph. OUT, 20 – 650kVA Powerware 3110 – 9150: 0,3 – 12kVA RECTIFIERS & BATTERY CHARGERS BCS: Battery Charger Single phase Thyristor equipped, with mains isolation transformer, automatic and manual high rate charge with timer Output: 12 – 220VDC, 10 – 100A TPRB: Three Phase Rectifier Battery charger Thyr. equipped, with mains isol. transf., autom. and man. high rate charge with t., battery current limitation Output: 24 – 220VDC, 50 – 1000A BDT: Thyristor Rectifier Charger with Digital Control Thyr. equipped, with mains isol. transf., autom. and man. high rate charge with t., battery current limitation, comm. interfaces, autom. and man. battery test, parallel op.,.... Output: 24 – 220VDC, 50 – 1000A BSS / BST: Modular Switch Mode Rectifier Charger IGBT converter with 20kHz, input PFC, autom. and man. high rate charge with t., battery current limiter, comm. interfaces, parallel op., modular 19“ rack design, ... Output: 24 – 220VDC, 10 – 300A SMR, SNP, RKAS: Switch Mode Rectifier Charger Fully equipped Switch Mode Rectifier Charger Output: 12 – 220VDC, 2,5 – 200A SMR, SNP, RKAS BSS, BST BCS TPRB BDT S-1200 S-1100 S-4100 Powerware 3110 - 9150 S-4200

UPS – Uninterruptible Power Supplies - FARMEDICA · UPS – Uninterruptible Power Supplies ... • SAFT Nickel-Cadmium Batteries • Pocket Plate SBH, SBM, SBL, Ultima SLM, Ultima.Plus,

  • Upload
    buikien

  • View
    246

  • Download
    1

Embed Size (px)

Citation preview

Page 1: UPS – Uninterruptible Power Supplies - FARMEDICA · UPS – Uninterruptible Power Supplies ... • SAFT Nickel-Cadmium Batteries • Pocket Plate SBH, SBM, SBL, Ultima SLM, Ultima.Plus,

UPS, RECTIFIERS & BATTERY CHARGERS, INVERTERS, AC VOLTAGE STABILIZERS, INDUSTRIAL BATTERIES

UPS – Uninterruptible Power SuppliesAll UPS are equipped with IGBT technology, digitalcontrol, integrated static- and manual bypass switches, output isolation transformers, battery test and monitoring, RS232, RS485 and Ethernet SNMP interfaces. All areCE-marked and have a very high MTBF rate.

• S-1200S: 1-ph. IN, 1-ph. OUT, 5 – 10kVA

• S-1200T: 3-ph. IN, 1-ph. OUT, 7,5 – 15kVA

• S-1100: 3-ph. IN, 1-ph. OUT, 20 – 32kVA

• S-4200: 3-ph. IN, 3-ph. OUT, 10 – 15kVA

• S-4100: 3-ph. IN, 3-ph. OUT, 20 – 650kVA

• Powerware 3110 – 9150: 0,3 – 12kVA

RECTIFIERS & BATTERY CHARGERS• BCS: Battery Charger Single phase

Thyristor equipped, with mains isolation transformer,automatic and manual high rate charge with timerOutput: 12 – 220VDC, 10 – 100A

• TPRB: Three Phase Rectifier Battery chargerThyr. equipped, with mains isol. transf., autom. and man.high rate charge with t., battery current limitationOutput: 24 – 220VDC, 50 – 1000A

• BDT: Thyristor Rectifier Charger with Digital ControlThyr. equipped, with mains isol. transf., autom. and man.high rate charge with t., battery current limitation, comm.interfaces, autom. and man. battery test, parallel op.,.... Output: 24 – 220VDC, 50 – 1000A

• BSS / BST: Modular Switch Mode Rectifier ChargerIGBT converter with 20kHz, input PFC, autom. and man.high rate charge with t., battery current limiter, comm.interfaces, parallel op., modular 19“ rack design, ...Output: 24 – 220VDC, 10 – 300A

• SMR, SNP, RKAS: Switch Mode Rectifier ChargerFully equipped Switch Mode Rectifier ChargerOutput: 12 – 220VDC, 2,5 – 200A SMR, SNP, RKAS

BSS, BST

BCS TPRB BDT

S-1200 S-1100 S-4100

Powerware 3110 - 9150

S-4200

Page 2: UPS – Uninterruptible Power Supplies - FARMEDICA · UPS – Uninterruptible Power Supplies ... • SAFT Nickel-Cadmium Batteries • Pocket Plate SBH, SBM, SBL, Ultima SLM, Ultima.Plus,

UPS, RECTIFIERS & BATTERY CHARGERS, INVERTERS, AC VOLTAGE STABILIZERS, INDUSTRIAL BATTERIES

INVERTERS• IBS, ICS, IJS: 1-phase Inverters

Very high efficiency, 350% overload capability, remotecontrol, output short circuit proof, automatic shut-off atlow DC voltage, stand-by mode, CE mark, ...Input: 12 – 60VDC; Output: 400 – 7000W

• WPS, WPT: 1-ph. and 3-ph. InvertersIGBT-PWM technology, integrated static- and manualbypass switches, low DC shut-down, autom. operationInput: 48 – 220VDC, Output: 5 – 125kVA

• IDS, IDT: 1-ph. and 3-ph. InvertersFully dig. controlled, IGBT-PWM technology, integratedstatic- and manual bypass switches, comm. I/F, ...Input: 48 – 220VDC, Output: 5 – 250kVA

AC VOLTAGE STABILIZERS• Electro-Mechanical Stabilizers RSS....RXFT

Low internal impedance for high surge currents, inputtapings, very high efficiency, spike suppression, ultra-fast response, EMC compatible, CE marked, ...Single- and three phase models from 1,4 to 5470kVAOutput accuracy ± 0,5% or ± 5%

• Solid State Stabilizers SXS....SXTSolid state design, low internal imp. for high surgecurrents, input tapings, very high eff., spike suppression,ultra-fast response, EMC compatible, CE marked, ...Single- and three phase models from 0,34 to 360kVAOutput accuracy ± 0,5% or ± 5%

INDUSTRIAL BATTERIES• SAFT Nickel-Cadmium Batteries

• Pocket PlateSBH, SBM, SBL, Ultima SLM, Ultima.Plus, SPL

• Sintered PBESPH, NCX, SRM, SRX, MRX

• Lead-Acid Batteries

• Valve Regulated Lead Acid (VRLA)OPzV, AGM, Gel, ...

• Vented Lead Acid (VLA)OPzP, OPzS, OGi, GroE

IDS, IDT IBS, ICS, IJS

WPS, WPT

RSS.......RXFT SXS.......SXT

w w w . s t a t r o n . c o m

Page 3: UPS – Uninterruptible Power Supplies - FARMEDICA · UPS – Uninterruptible Power Supplies ... • SAFT Nickel-Cadmium Batteries • Pocket Plate SBH, SBM, SBL, Ultima SLM, Ultima.Plus,

UPS, RECTIFIERS & BATTERY CHARGERS, INVERTERS, AC VOLTAGE STABILIZERS, INDUSTRIAL BATTERIES

ZSV – Add. Power Supply for Hospital

• ZSV-SIndustrial construction – no modified UPS-system,IGBT technology, galvanic separation of the batterycircuit, parallel operation possible, simple yearlycapacity test, automatic monthly function test, electrical test book, messages and alarms acc. toDIN VDE 0107, batteries incl. 20% capacity reserveacc. DIN VDE 0510 part 2, table 5Output power: 3kVA – 80kVA

• ZSV OP LuxSecure 24V power supply for operation lamps acc. toDIN VDE 0107 (0100 – 710), controlled output voltagefor long lifetime of the OP lamps, ISO-DC-surveillanceof the outgoing circuits, automatic monthly function testelectrical test book, batteries incl. 20% capacity reserveacc. DIN VDE 0510 part 2, table 5Output power: 200W – 4600W

EMERGENCY LIGHTING

• Stand-by lighting

• Escape route signaling

• Anti panic lighting

• High risk task area lighting

• Central Battery Lamps

• Single Battery Lamps

• Datacenter WCentral surveillance, decentral power supplyDatacenter W can monitor up to 1250 lamps.

ZSV-S

ZSV OP Lux

w w w . s t a t r o n . c o m

Datacenter W