Applications Include: Industrial processing, laboratory and bio-medical research facilities, hospitals, universities, offi ce buildings and building complexes, sterilization facilities, semi-conductor facilities, paper and pulp factories, laundries or applications with special steam requirements and also point-of-use steam needs.

UNFIRED STEAM BOILERSSteam • High-Temp Water • Thermal FluidsProcess Steam • Clean Steam • Pure Steam

Unfi red Steam BoilersAJAX boilers perform dependably and quietly, engineered to meet specifi c steam needs for industrial, institutional and commercial facilities. Quality U-tube bundles provide uniform heat transfer, resulting in high thermal effi ciency and long boiler life.

66

A.S.M.E.

Features• Properly sized, with horizontal, vertical, and compact Mini-Pack™ style boiler choice• Moisture separator for dry steam• Independent bolting for easy inspection and maintenance• Quality components for high performance and best value• Wide range of options available

Standard EquipmentTank• A.S.M.E. Section VIII Div I vessel• National Board registered• 50 psig design working pressure• Horizontal, carbon steel construction with internal steam separator• 12" x 16" manway on 42" diameter and larger tanks; inspection openings for below 42"• Lifting lugs• Process steam application

Tube Bundle• 150 psig design working pressure• SB-75 seamless copper U-tube• Single wall tubing• Removable bundle• Steel cap and tubesheet• Lifting straps or lugs

Support• Skid mounted horizontal tank with saddles

Controls• Pilot operated steam control valve• ASME pressure relief valve• Main T&P steam trap• Pressure gauge panel with high limit switch• Steam cap pressure gauge• Conductivity type feed water and level control

Insulation & Jacketing• Mirror fi nish stainless steel jacket• 2" insulation

Page 3: Unfired Steam Boilers

Photo may vary from actual model

Optional EquipmentTank• 150 psig design working pressure• Vertical & compact Mini-Pack™ style models available• Clean or Pure steam application with stainless steel construction

Tube Bundle• Copper, 90/10 cupro-nickel or 304/316 stainless steel tubing

Support• Vertical: skid mounted with pipe legs• Mini-Pack™ style: steel stand

Controls• Pneumatic, or electric control valve• Feed water solenoid valve• By-pass for feed water• Auxillary high water probe alarm• Bottom blow down system• Surface blow down system - Solenoid assembly with clock - TDS or conductivity blow down system• Relay contacts for BMS• 4-20mA transmission• ModBus capability• Secondary low water cut-off

Insulation & Jacketing• 3" insulation

Process SteamUnfi red steam boilers are used to protect fi red boilers from harmful chemicals in the return condensate, such as in pulp and paper processing. Unfi red steam boiler tube bundles and/or drum can be fabricated using materials that will be cost effective for the process steam condition. These can range from copper tube bundles and pressure vessel quality steel to tube bundles made from cupro-nickel or stainless steel tubing and drums fabricated with stainless steel.

Clean SteamClean steam unfi red steam boilers provide clean steam by using feed water that is free from boiler water treatment chemicals. Clean steam is used by the food industry for cooking and cleaning and is also used for many sterilization and humidifi cation applications.

Pure SteamMore and more applications are requiring ultra pure steam for sterilization in Bio-science research, pharmaceutical research and/or processing, medical sterilization and high-tech clean room humidity control.

Pure steam boilers are normally fabricated with special high quality stainless steel pressure vessel material and components to handle the aggressive feedwater used in these applications.

67

Series

Page 4: Unfired Steam Boilers

Unfi red Steam Boilers

Level Control DrainFPT

CondensateOut

G

Steam Inlet

A

9”

FPTFeed Water Inlet

FPTBottom Blow Down

D

E

F

FPT Outlet

SteamSeparator

FLG Steam Outlet

6”

Lift Lug / strap2 Places

OVL

FPTSurface Blow Down

HORIZONTALPILOT-OPERATED

68

A.S.M.E.

Page 5: Unfired Steam Boilers

TANKDIA.

SHELLLENGTH A D E F G OVL

18"

24 62 3 8 18 20 3636 74 3 8 18 20 4848 86 3 8 18 20 6060 98 3 8 18 20 72

24"

48 95 3 8 24 26 6360 107 3 8 24 26 7572 119 3 8 24 26 8784 131 3 8 24 26 99

30"

48 100 3 8 30 33 6660 112 3 8 30 33 7872 124 3 8 30 33 9084 136 3 8 30 33 10298 148 3 8 30 33 114

36"

48 106 3 8 36 39 6960 118 3 8 36 39 8172 130 3 8 36 39 9384 142 3 8 36 39 10598 154 3 8 36 39 117

42"

48 109 3 8 42 45 7260 121 3 8 42 45 8472 133 3 8 42 45 9684 145 3 8 42 45 10898 157 3 8 42 45 120

48"

48 112 3 8 48 51 7560 124 3 8 48 51 8772 136 3 8 48 51 9984 148 3 8 48 51 11198 160 3 8 48 51 123

54"

60 127 4 8 54 58 9072 139 4 8 54 58 10284 151 4 8 54 58 11498 163 4 8 54 58 126

60"

60 130 4 8 60 64 9372 142 4 8 60 64 10584 154 4 8 60 64 11798 166 4 8 60 64 129110 178 4 8 60 64 141

66"

60 133 4 8 66 70 9672 145 4 8 66 70 10884 157 4 8 66 70 12098 169 4 8 66 70 132110 181 4 8 66 70 144

72"

60 136 4 8 72 76 9972 148 4 8 72 76 11184 160 4 8 72 76 12398 172 4 8 72 76 135110 184 4 8 72 76 147

Standard Dimensions

Horizontal Tank Sizes

69

Series

Page 6: Unfired Steam Boilers

A

6”

FPTSurfaceblow down

FPT Feed Water Inlet

OVL

SIDE VIEW DIM.FRONTVIEWDIM.

FPTBottom blow down

Level ControlDrain FPT

CondensateOut

SteamInlet

FPT Outlet

FLG Steam Outlet

Unfi red Steam Boilers

VERTICALPILOT-OPERATED

70

A.S.M.E.

Page 7: Unfired Steam Boilers

TANKDIA.

SHELLLENGTH

FrontView

SideView A OVL

18"

24 25 473/8 11 3636 25 473/8 11 4848 25 473/8 11 6060 25 473/8 11 72

24"

48 31 597/8 11.5 6360 31 597/8 11.5 7572 31 597/8 11.5 8784 31 597/8 11.5 99

30"

48 37 677/8 14 6660 37 677/8 14 7872 37 677/8 14 9084 37 677/8 14 10298 37 677/8 14 114

36"

48 43 763/8 12.5 6960 43 763/8 12.5 8172 43 763/8 12.5 9384 43 763/8 12.5 10598 43 763/8 12.5 117

42"

48 49 823/8 16.5 7260 49 823/8 16.5 8472 49 823/8 16.5 9684 49 823/8 16.5 10898 49 823/8 16.5 120

48"

48 551/4 893/8 16 7560 551/4 893/8 16 8772 551/4 893/8 16 9984 551/4 893/8 16 11198 551/4 893/8 16 123

54"

60 611/4 953/8 14 9072 611/4 953/8 14 10284 611/4 953/8 14 11498 611/4 953/8 14 126

60"

60 671/4 1013/8 14 9372 671/4 1013/8 14 10584 671/4 1013/8 14 11798 671/4 1013/8 14 129

110 671/4 1013/8 14 141

66"

60 731/4 1073/8 15 9672 731/4 1073/8 15 10884 731/4 1073/8 15 12098 731/4 1073/8 15 132

110 731/4 1073/8 15 144

72"

60 791/2 1143/8 15.5 9972 791/2 1143/8 15.5 11184 791/2 1143/8 15.5 12398 791/2 1143/8 15.5 135

110 791/2 1143/8 15.5 147

Standard Dimensions

Vertical Tank Sizes

71

Series

Page 8: Unfired Steam Boilers

HEAT EXCHANGERS &TUBE BUNDLESDouble-Wall and Single-Wall

Heat Exchangers & Tube BundlesAJAX exchangers perform dependably and quietly, offering a variety of water heating solutions. Quality U-tube bundles provide uniform heat transfer, resulting in high thermal effi ciency and long exchanger life.

72

Tube BundlesFeatures• Optimized design for best heat transfer performance in steam, water and HTW exchanger type heaters • Wide variety of models to suit your specific need: • Single wall or double wall tube bundle • 150, 250, or 400 psig working pressure design • Copper, cupro-nickel 90/10, or stainless steel tubing • Coil sizes from 4" up to 30" on selected models • Carbon steel or stainless steel tubesheet and cap

Double-Wall Tube BundlePhoto may vary from actual model

Fully visible 360º vented leak detection between tubesheets. A.S.M.E.

Page 9: Unfired Steam Boilers

Heat ExchangersFeatures• Optimized design for best heat transfer performance in steam, water and HTW exchangers • Single wall and double wall tube bundles available

Standard EquipmentShell• ASME Section VIII Div I vessel• National Board registered• 150 psig design working pressure• Horizontal, carbon steel construction

Tube Bundle• 150 psig design working pressure• SB-75 seamless copper U-tube• Single wall tubing• Steel cap and tubesheet

Optional EquipmentTube Bundle• HTW applications• 0.049" wall copper, 90/10 Cupro-nickel 304 or 316L tubes• Double wall tubing• 304 stainless steel tube sheet and cap fl ange

Support• Saddles

Condensate Cooler / Feedwater ExchangerPhoto may vary from actual model

73

A.S.M.E.

Series

Page 10: Unfired Steam Boilers

Heat Exchangers & Tube Bndles

74

NOMINALCOILSIZE

DIMENSION COMMONTO 2, 4, & 6 PASS 2-PASS 4-PASS 6-PASS

A F G K L M C D C D C D

*5 59/16 8 1 3 2 1 11/4 13/8 11/4 13/8 - -6 65/8 8 1 3 21/2 1 11/2 15/8 11/2 15/8 1 18 85/8 9 11/4 31/2 4 F 11/4 21/2 21/8 2 21/8 11/2 13/810 103/4 11 11/2 47/8 4 F 11/2 3 23/4 21/2 23/4 2 15/812 123/4 15 2 41/8 5 F 2 4 31/4 3 31/4 21/2 214 14 17 2 43/8 6 F 2 4 31/2 3 31/2 21/2 21/416 16 19 21/2 415/16 6 F 21/2 5 4 4 4 3 21/2

CAP/BONNET CONFIGURATIONCAP/BONNET CONFIGURATION

2-PASS 4-PASS 6-PASS

C

C

C

CC

C

DD

DK

Model SU - Service Water in Tubes with Steam in Shell

NOMINALCOILSIZE

HDouble-

Wall

J

*SU_0502__ 40 293/4*SU_0503__ 52 413/4*SU_0504__ 64 533/4*SU_0505__ 76 653/4*SU_0506__ 88 773/4*SU_0507__ 100 893/4SU_0602__ 421/4 281/2SU_0603__ 541/4 401/2SU_0604__ 661/4 521/2SU_0605__ 781/4 641/2SU_0606__ 901/4 761/2SU_0607__ 1021/4 881/2SU_0802__ 573/4 421/2SU_0803__ 683/4 531/2SU_0804__ 803/4 651/2SU_0804__ 933/4 781/2SU_0806__ 1043/4 891/2SU_0807__ 1163/4 1011/2SU_1002__ 621/4 431/2SU_1003__ 741/4 551/2SU_1004__ 861/4 671/2SU_1005__ 981/4 791/2SU_1006__ 1101/4 911/2SU_1007__ 1221/4 1031/2SU_1202__ 781/4 551/4SU_1203__ 901/4 671/4SU_1204__ 1021/4 791/4SU_1205__ 1141/4 911/4SU_1206__ 1261/4 1031/4SU_1207__ 1381/4 1151/4SU_1402__ 83 571/4SU_1403__ 95 691/4SU_1404__ 107 811/4SU_1405__ 119 931/4SU_1406__ 131 1051/4SU_1407__ 143 1171/4SU_1602__ 88 591/4SU_1603__ 100 711/4SU_1604__ 112 831/4SU_1605__ 124 951/4SU_1606__ 136 1071/4SU_1607__ 148 1191/4

Drawing shows rough dimensions only.Contact factory for specifi c information.

NOTE: “H” dimension is approximate. “C”, “D”, “L” & “M” are standard sizes, however, they should be sized to particular fl ow requirements. For longer or shorter models, consult factory.

Double-Wall

DOUBLE-WALL TUBELEAK DETECTION AREA

A

H

J

M

FG 3/4" L

3/4"

K

NOTE: “H” dimension is approximate. “C”, “D”, “L” & “M” are standard sizes, however, they should be sized to particular fl ow requirements. For longer or shorter models, consult factory.

A

H

J

M

FG 3/4" L

3/4"

Single-Wall

K

NOMINALCOILSIZE

HSingle-

Wall

J

*SU_0502__ 39 293/4*SU_0503__ 51 413/4*SU_0504__ 63 533/4*SU_0505__ 75 653/4*SU_0506__ 87 773/4*SU_0507__ 99 893/4SU_0602__ 411/4 281/2SU_0603__ 531/4 401/2SU_0604__ 651/4 521/2SU_0605__ 771/4 641/2SU_0606__ 891/4 761/2SU_0607__ 1011/4 881/2SU_0802__ 561/2 421/2SU_0803__ 671/2 531/2SU_0804__ 791/2 651/2SU_0804__ 921/2 781/2SU_0806__ 1031/2 891/2SU_0807__ 1151/2 1011/2SU_1002__ 603/4 431/2SU_1003__ 723/4 551/2SU_1004__ 843/4 671/2SU_1005__ 963/4 791/2SU_1006__ 1083/4 911/2SU_1007__ 1203/4 1031/2SU_1202__ 763/4 551/4SU_1203__ 883/4 671/4SU_1204__ 1003/4 791/4SU_1205__ 1123/4 911/4SU_1206__ 1243/4 1031/4SU_1207__ 1363/4 1151/4SU_1402__ 811/4 571/4SU_1403__ 931/4 691/4SU_1404__ 1051/4 811/4SU_1405__ 1171/4 931/4SU_1406__ 1291/4 1051/4SU_1407__ 1411/4 1171/4SU_1602__ 86 591/4SU_1603__ 98 711/4SU_1604__ 110 831/4SU_1605__ 122 951/4SU_1606__ 134 1071/4SU_1607__ 146 1191/4

* 5" heat exchangers are equipped with flat heads instead of SE heads

A.S.M.E.

Page 11: Unfired Steam Boilers

NOMINALCOILSIZE

DIMENSION COMMONTO 2, 4, & 6 PASS 2-PASS 4-PASS 6-PASS

A F G K L M C D C D C D

*5 59/16 8 3 35/8 2 2 11/4 13/8 11/4 13/8 - -6 65/8 8 3 315/16 21/2 21/2 11/2 15/8 11/2 15/8 1 18 85/8 9 51/2 45/8 4F 4F 21/2 21/8 2 21/8 11/2 13/810 103/4 11 51/2 47/8 4F 4F 3 23/4 21/2 23/4 2 15/812 123/4 15 6 51/2 5F 5F 4 31/4 3 31/4 21/2 214 14 17 7 63/16 6F 6F 4 31/2 3 31/2 21/2 21/416 16 19 7 67/16 6F 6F 5 4 4 4 3 21/2

Model WU - Service Water in Tubes with Water in Shell

Drawing shows rough dimensions only.Contact factory for specifi c information.

75

NOTE: “H” dimension is approximate. “C”, “D”, “L” & “M” are standard sizes, however, they should be sized to particular fl ow requirements. For longer or shorter models, consult factory.

A

H

J

M

FG 3/4" L

3/4"

Single-Wall

K

NOTE: “H” dimension is approximate. “C”, “D”, “L” & “M” are standard sizes, however, they should be sized to particular fl ow requirements. For longer or shorter models, consult factory.

DOUBLE-WALL TUBELEAK DETECTION AREA

A

H

J

M

FG 3/4" L

3/4"

Double-Wall

K

CAP/BONNET CONFIGURATIONCAP/BONNET CONFIGURATION

2-PASS 4-PASS 6-PASS

C

C

C

CC

C

DD

DD

NOMINALCOILSIZE

HDouble-

Wall

J

*WU_0502__ 351/2 251/4*WU_0503__ 471/2 371/4*WU_0504__ 591/2 491/4*WU_0505__ 711/2 611/4*WU_0506__ 831/2 731/4*WU_0507__ 951/2 851/4WU_0602__ 363/4 23WU_0603__ 483/4 35WU_0604__ 603/4 47WU_0605__ 723/4 59WU_0606__ 843/4 71WU_0607__ 963/4 83WU_0802__ 491/4 34WU_0803__ 611/4 46WU_0804__ 731/4 58WU_0804__ 851/4 70WU_0806__ 971/4 82WU_0807__ 1091/4 94WU_1002__ 523/4 34WU_1003__ 643/4 46WU_1004__ 763/4 58WU_1005__ 883/4 70WU_1006__ 1003/4 82WU_1007__ 1123/4 94WU_1202__ 68 45WU_1203__ 80 57WU_1204__ 92 69WU_1205__ 104 81WU_1206__ 116 93WU_1207__ 128 105WU_1402__ 703/4 45WU_1403__ 823/4 57WU_1404__ 943/4 69WU_1405__ 1063/4 81WU_1406__ 1183/4 93WU_1407__ 1303/4 105WU_1602__ 723/4 44WU_1603__ 843/4 56WU_1604__ 963/4 68WU_1605__ 1083/4 80WU_1606__ 1203/4 92WU_1607__ 1323/4 104

NOMINALCOILSIZE

HSingle-

Wall

J

*WU_0502__ 341/2 251/4*WU_0503__ 461/2 371/4*WU_0504__ 581/2 491/4*WU_0505__ 701/2 611/4*WU_0506__ 821/2 731/4*WU_0507__ 941/2 851/4WU_0602__ 353/4 23WU_0603__ 473/4 35WU_0604__ 593/4 47WU_0605__ 713/4 59WU_0606__ 833/4 71WU_0607__ 953/4 83WU_0802__ 48 34WU_0803__ 60 46WU_0804__ 72 58WU_0804__ 84 70WU_0806__ 96 82WU_0807__ 108 94WU_1002__ 511/4 34WU_1003__ 631/4 46WU_1004__ 751/4 58WU_1005__ 871/4 70WU_1006__ 991/4 82WU_1007__ 1111/4 94WU_1202__ 661/2 45WU_1203__ 781/2 57WU_1204__ 901/2 69WU_1205__ 1021/2 81WU_1206__ 1141/2 93WU_1207__ 1261/2 105WU_1402__ 69 45WU_1403__ 81 57WU_1404__ 93 69WU_1405__ 105 81WU_1406__ 117 93WU_1407__ 129 105WU_1602__ 703/4 44WU_1603__ 823/4 56WU_1604__ 943/4 68WU_1605__ 1063/4 80WU_1606__ 1183/4 92WU_1607__ 1303/4 104

* 5" heat exchangers are equipped with flat heads instead of SE heads

A.S.M.E.

Series

Page 12: Unfired Steam Boilers

84

The Ajax Boiler Factory limited warranty provides assurance that all products are free from manufactures defects at the time of shipment and meet specifi cations and performance described in the product literature. It is important to understand the difference between a factory warranty and an installed warranty. There are many factors that can occur to the products after they are shipped that the company has no control over and cannot fully verify. These include: 1. Hidden damage during the shipping 2. Handling damage 3. Damage during storage 4. Installation conditions 5. Other unknown variables in the system design, operations, maintenance, pulsation and vibrations.

The installed warranty is the responsibility of the architect, specifying engineer, contractor and or owner who jointly have control over the application, installation, location, operating and maintenance conditions. The AJAX BOILER INC. warranty excludes extended liabilities. Extended liability typically occurs when products are installed without proper drainage, fl ooding containment or when safety devices are not tested and repaired or replaced when needed. Product problems are often caused by the condition of the water, the lack of water treatment and or the improper treatment of the water, insuffi cient combustion air, improper draft conditions, bolts not re-tightened, pipes not fl ushed and cleaned of oil, metal chips, rags, vibration and pulsation etc. These are installation, operating and/or maintenance conditions that are beyond the seller’s responsibility and are not covered by the factory warranty, but may be covered by the installer’s warranty. The factory warranty covering company products is based upon extensive product development and testing. Combustion products under go certifi cation testing and approvals to Underwriters Laboratory standards. Auditing of the production of combustion products is conducted by a nationally recognized testing laboratory. Pressure vessel products are designed and manufactured to American Society of Mechanical Engineering (A.S.M.E.) and National Board (NB) Design standards. Design reviews, factory product manufacturing quality inspections and testing are carried out by a third party National Board authorized inspection agency. AJAX BOILER INC. products have proven themselves in service for over 85 years which indicates that the company products perform exceedingly well when normal installation, operating

and maintenance conditions exist. The following is a review from the terms and conditions of sale. Also included in paragraph two, below, is the AJAX BOILER INC. non-conformance policy.

1. AJAX BOILER INC. warrants its products against defective material and/or workmanship only. The warranty does not apply to operational failures, electrical failures, gasket leaks, and or other malfunctions caused by improper application, installation and or maintenance.2. It is the buyer’s responsibility to inspect and accept the product, when received, as conforming to their purchase order, specifi cations and approved drawings. All claims for non-conformance, errors, shortages, etc. must be made within 10 days after receipt of the shipment.3. AJAX BOILER INC. do not provide a warranty or guarantee, express or implied, in any manner, form, usage of trade, merchant-ability or fi tness which extend beyond the product description and quotation.4. AJAX BOILER INC. liability is limited to the factory repair or replacement of warranty failures, or non-conformance, upon the return of the product to the factory.5. AJAX BOILER INC. is not liable for any direct or consequential damages.6. The AJAX BOILER INC. warranty is based upon section 23161(2) of the uniform commercial code and is printed in the terms and conditions of sale which is referenced in every quotation, on the back of sales order acknowledgements and invoices. It is legally correct and is an industry standard policy.

THERMAL SHOCK In addition to our standard one (1) year warranty against defective parts and workmanship, AJAX BOILER INC. provides the following guarantee with all commercial hot water, forced circulation, space heating boilers: AJAX BOILER INC. guarantees this new boiler pressure vessel for ten (10) years after date of installation from damage due to thermal shock. Thermal shock occurs when cold makeup water, up to 150°F less than the boiler water outlet temperature, is added directly into the boiler while the boiler is operating within the normal temperature range from 140°F to 250°F with a temperature rise from 20°F to 40°F. This guarantee shall cover damage to the boiler tubes, tube headers, and tube sheets when such damage is attributed to unequal expansion, poor circulation and/or other causes quite often described as “thermal shock.” This guarantee does not cover damage or failures that can

Page 13: Unfired Steam Boilers

85

be attributed to corrosion, condensation, scale, boiler treatment chemicals, dirt accumulation, low water conditions, or any other abnormal operating conditions. The liability of AJAX BOILER INC. is limited solely to the replacement of the complete pressure vessel, with tubes, if found by our inspection to be damaged by thermal shock. In no event shall AJAX BOILER INC. be held liable for replacement labor charges or for freight or handling charges.

AJAX BOILER INC. provides a limited warranty on its products aganst defective material and/or workmanship only. This limited warranty is not applicable to operational failures, electrical failures, gasket leaks, wear or malfunctions caused by improper application, installation, and/or maintenance.

The following Limited Warranty periods are from date of shipment: Boiler Pressure Vessels: One year.Carbon Steel Tank and Heat Exchanger Pressure Vessels: One year.Stainless Steel Tanks: Three years.Boiler Copper Fin Coils: Three years.High Effi ciency Condensing Boiler: One Year (Three years on Coil).Single-Wall or Double-Wall Tank/Exchanger Coils: One year.Single-Wall or Double-Wall Mini-Packs: One year.Atlas Series Condensing Boiler: One year.Linings: (Pro-Rated Warranty) Section VIII Tanks: Glass 36” dia. and above (fi ve years). Glass 30” dia. and under (one year). Cement (fi ve years). Prekrete (ten years). In Section IV Tanks: Glass (one year).Controls: Components manufactured by other than AJAX BOILER INC. such as controls, instruments, forced draft burner, etc., provided with the boilers and packaged products are not covered by the AJAX BOILER INC. Warranty. However, AJAX BOILER INC. extends to the customer the same warranty provided by the manufacturer to AJAX BOILER INC. The customer shall receive the full benefi ts of adjustments made to AJAX BOILER INC. by the manufacturer.

Any claim for adjustment under this limited warranty must be made within the warranty period. AJAX BOILER INC.’s liability shall be limited to factory repair

or, at AJAX BOILER INC.’s option, replacement of all parts which, upon test and examination by AJAX BOILER INC., prove to be defective material and or workmanship and within the above limited warranty. If required by AJAX BOILER INC., parts which are claimed to be defective must be promptly delivered to the AJAX BOILER INC. facility, transportation charges prepaid. This warranty does not cover the cost of labor, removal, or installation of the warranted item during the limited period. This warranty is limited to the above and applies only for the period set forth. AJAX BOILER INC. will not be liable for any loss damage, direct, incidental or consequential damages of any kind, whether based upon warranty, contract, negligence or strict liability and arising in connection with the sale, use or repair of the products. AJAX BOILER INC.’s maximum liability shall not exceed the contract price for the products or component claimed to be defective or unsuitable. AJAX BOILER INC. does not warrant the product’s merchantability or fi tness for any particular purpose and in no event shall be held responsible for any consequential damages.

For complete Limited Warranty conditions see Section G and H under terms and conditions of sale.

The brand and product names contained within are trademarks or registered of their respective holders. Performance, dimensions, specifi cations are effective with date of issue and are subject to change without prior notice. AJAX BOILER INC. maintains a policy of continuous improvements and therefore reserves the right to change specifi cation without notice. AJAX BOILER INC. cannot be responsible for errors in typography or photography.

Page 14: Unfired Steam Boilers

Ajax Boiler, Inc. designs and manufactures a comprehensive line of boiler and commercial water

heating products. With over eight decades of experience, the company offers high quality, heavy

duty products with reputations for reliability, serviceability, and cost effective operation.

The administrative offi ces and manufacturing facility of Ajax Boiler, Inc. are located in Santa Ana,

California. All products are designed and engineered by our in-house engineering department

whose expertise combine the disciplines of combustion and heat transfer technology, pressure

vessel design, control and systems engineering, and computer aided design. Our on-site R&D

facility has the capacity to test fi re boilers up to 21,000,000 BTU/hour under load conditions

with calibrated test equipment that meet all UL certifi cation testing requirements. Product lines

are distributed by more than 70 sales representatives located throughout the United States and

Canada.

Ajax Series (Space Heating and Process Steam & Hot Water) • Inclined water tube boilers• High & low pressure steam boilers• Unfi red steam boilers• Heat exchangers• Tanks (Flash, Expansion, Blow Down, and Condensate Return Feedwater)

Ace Series (Plumbing and Domestic Hot Water) • Mini-Pack semi-instantaneous, indirect water heaters• Gas-fi red conical copper fi n water heaters• Indirect storage water heaters• Tanks (Storage)

Atlas Series• High-effi ciency, condensing boilers and water heaters