44
TYPICAL ROOF CONDITION LAYOUT 1 3 16 Typical Roof Condition Layout............................... Low Eave Isometric Floating................................... Low Eave Floating ................................................. High Eave Floating ............................................. High Eave Fixed ................................................. Wall to Roof High Eave Floating............................. Wall to Roof High Eave Fixed................................. Panel Slope Transition Floating.............................. Panel End & Closure Isometric............................... Center Clip Fixed ................................................... Low Eave Gutter Isometric Floating........................ Low Eave Gutter Floating....................................... Internal Gutter......................................................... Internal Gutter At Parapet Wall............................... Internal Gutter ........................................................ Hip/Ridge Cap Floating........................................... Hip/Ridge Cap Floating........................................... Vented Ridge Fixed................................................ Hip To Rake Transition........................................... Hip To Rake Transition........................................... Hip - Floating........................................................... Rake Detail.............................................................. Rake At Stepped Eave.................................................... Rake Installation.............................................................. Wall to Rake Flashing..................................................... Wall At Sloping To Flat Roof........................................... Wall To Rake Step Flashing........................................... Wall To Rake Expansion Joint........................................ Panel Expansion Joint.................................................... Rake At Valley Isometric................................................ Rake At Valley................................................................ Equipment Curb Flashing Plan....................................... Equipment Curb Flashing Isometric................................ Equipment Curb Flashing - Section B............................. Equipment Curb Flashing - Section C............................. Equipment Curb Flashing - Section D............................. Pipe Penetration............................................................. Gutter Flashing .............................................................. Rake And Eave Flashing Condition................................ Rake And Hip Flashing Condition................................... Downspout...................................................................... Knee Detail..................................................................... Snow Guard.................................................................... Lighting Protection.......................................................... 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 18 29 37 19 35 6 47 FIXED POINTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 7 15 11 20

UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

TYPICAL ROOF CONDITION LAYOUT

1

3

16

Typical Roof Condition Layout...............................

Low Eave Isometric Floating...................................

Low Eave Floating .................................................

High Eave Floating .............................................

High Eave Fixed .................................................

Wall to Roof High Eave Floating.............................

Wall to Roof High Eave Fixed.................................

Panel Slope Transition Floating..............................

Panel End & Closure Isometric...............................

Center Clip Fixed ...................................................

Low Eave Gutter Isometric Floating........................

Low Eave Gutter Floating.......................................

Internal Gutter.........................................................

Internal Gutter At Parapet Wall...............................

Internal Gutter ........................................................

Hip/Ridge Cap Floating...........................................

Hip/Ridge Cap Floating...........................................

Vented Ridge Fixed................................................

Hip To Rake Transition...........................................

Hip To Rake Transition...........................................

Hip - Floating...........................................................

Rake Detail..............................................................

Rake At Stepped Eave....................................................

Rake Installation..............................................................

Wall to Rake Flashing.....................................................

Wall At Sloping To Flat Roof...........................................

Wall To Rake Step Flashing...........................................

Wall To Rake Expansion Joint........................................

Panel Expansion Joint....................................................

Rake At Valley Isometric................................................

Rake At Valley................................................................

Equipment Curb Flashing Plan.......................................

Equipment Curb Flashing Isometric................................

Equipment Curb Flashing - Section B.............................

Equipment Curb Flashing - Section C.............................

Equipment Curb Flashing - Section D.............................

Pipe Penetration.............................................................

Gutter Flashing ..............................................................

Rake And Eave Flashing Condition................................

Rake And Hip Flashing Condition...................................

Downspout......................................................................

Knee Detail.....................................................................

Snow Guard....................................................................

Lighting Protection..........................................................

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

18

29

37

19

35

6

47

FIXED POINTS

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

10

2

17

42

4

5

13

12

22

23

34

36

36

7

15

11

20

Page 2: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

BUTYL TUBE SEALANT

RIGID INSULATION (NBM)

ROOF DECK (NBM)

#6 HEX TEK.

(4) PER PANEL MIN.

OR POP RIVETS

DRIP ANGLE

SLR FIXED

OR SLIDING CLIP

EAVE FLASHING

SLR PANEL

40 MIL. ICE AND WATER SHIELD

UNDERLAYMENT (NBM)

BUTYL TUBE SEALANT

LOW EAVE ISOMETRIC-FLOATING

2

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 3: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

SLR PANEL

BUTYL TUBE

SEALANT

EAVE TRIM

UNDERLAYMENT

(NBM)

RIGID INSULATION

(NBM)

ROOF DECK

(NBM)

FASTENERS (2) PER

CLIP MIN.

1"X1" DRIP

ANGLE

LOW EAVE-FLOATING

3

Eave design must be able to allow for the total amount of expansion of the panel if the ridge is fixed. A drip trim

should be used to stiffen the flat of the panel and block wind driven rain. This piece also assists in limiting the

amount of bow of the flat under high wind.

Since sealant between roof underlayment and panel may limit expansion or rupture, protection against wind

blown water infiltration is provided by folding the panel under, which allows for thermal expansion.

Detail must be designed to allow for maximum thermal movement. Floating eave requires fixed ridge.

6

"

-

8

"

m

a

x

im

u

m

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

SLR CLIP

1

"

m

in

.

Page 4: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

SLR CLIP

RIDGE CAP

FASTENERS (2)

PER CLIP MIN.

RIGID INSULATION

(NBM)

FASTENERS (5)

PER PANEL MIN.

BEARING PLATE

Note:

-Floating high eave requires fixed low eave.

-Gap as required for thermal movement.

-Use J-support for panel with Clip Relief, Pencil Ribs and Striated.

ROOF DECK

(NBM)

SEALANT AROUND

NOTCHED RIBS

"J" SUPPORT AT

PANEL ENDS

HIGH EAVE - FLOATING

CONTINUOUS "Z"

NOTCHED AROUND

PANELS RIBS IN FIELD

HIGH HEAT ICE AND

WATER SHIELD REQ'D

40 MIL MIN. (NBM)

4

SEALANT

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 5: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

HIGH EAVE - FIXED

Note:

-Fixed high eave requires floating low eave

-Gap as required for thermal movement

- Use J- support for panel with Clip Relief, Pencil Ribs and Striated

RIDGE CAP

FASTENERS (5)

PER PANEL MIN.

"J" SUPPORT AT

PANEL ENDS

FIXED SLR CLIP

SEALANT AROUND

NOTCHED RIBS

RIGID INSULATION

(NBM)

BEARING PLATE

ROOF DECK

(NBM)

CONTINUOUS "Z"

NOTCHED AROUND

PANELS RIBS IN FIELD

HIGH HEAT ICE AND

WATER SHIELD REQ'D

40 MIL MIN. (NBM)

5

SEALANT

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

FIXED FASTENERS

2 PER PANEL

FASTENERS (2)

PER CLIP MIN.

Page 6: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

FASTENERS (2) PER CLIP MIN.

ROOF DECK

(NBM)

SLR FLOATING CLIP

SEALANT (NBM)

HIGH EAVE

FLASHING

MASONRY FASTENER

BUTYL SEALANT

2" MIN.

FASTENERS (5) PER

PANEL MIN.

SEALANT

AROUND RIBS

"Z" CLOSURE

NOTCH AROUND

RIBS IN FIELD

"J" SUPPORT AT

PANEL ENDS

THROUGH WALL FLASHING

WALL TO ROOF HIGH EAVE - FLOATING

6

High eave flashings are similar to ridge conditions. Attention must be given to the design for sealing and panel

movement. Where snow buildup is a concern the design of the trim must take into account the excess loading.

Floating high eave requires fixed low eave. Use J- support for panel with clip relief, pencil ribs and striated.

Floating high eave requires fixed low eave and fixed high eave required floating eave.

URETHANE SEALANT

BETWEEN FLASHING

AND MASONRY

SEALANT

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 7: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

FASTENERS (2) PER CLIP MIN.

ROOF DECK

(NBM)

SEALANT (NBM)

HIGH EAVE

FLASHING

MASONRY FASTENER

BUTYL SEALANT

2" MIN.

FASTENERS (5) PER

PANEL MIN.

"J" SUPPORT AT

PANEL ENDS

THROUGH WALL FLASHING

WALL TO ROOF HIGH EAVE - FIXED

7

High eave flashings are similar to ridge conditions. Attention must be given to the design for sealing and panel

movement. Where snow buildup is a concern the design of the trim must take into account the excess loading.

Floating high eave requires fixed low eave. Use J- support for panel with clip relief, pencil ribs and striated.

Floating high eave requires fixed low eave and fixed high eave required floating eave.

URETHANE SEALANT

BETWEEN FLASHING

AND MASONRY

SEALANT

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

SLR FIXED CLIP

SEALANT

AROUND RIBS

"Z" CLOSURE

NOTCH AROUND

RIBS IN FIELD

Page 8: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

PANEL SLOPE TRANSITION - FLOATING

Note:

- Floating panels require fixed connections at opposite ends.

- Use J- support for panel with clip relief, pencil ribs and striated.

8

SLR CLIP

BUTYL TUBE SEALANT

FASTENERS

(2) PER CLIP MIN.

METAL DECK (NBM)

RIGID INSULATION (NBM)

SLR CLIP

CONTINUOUS "Z"

CLOSURE NOTCH

AROUND RIBS IN FIELD

SEALANT AROUND RIBS

1

8

"X1" CONTINUOUS

BUTYL TAPE

"J" SUPPORT AT

PANEL ENDS

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

TRANSITION FLASHING

Page 9: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

"Z" CLOSURE NOTCHED

AROUND RIBS IN FIELD

SLR PANEL

CONTINUOUS LINE OF

DOUBLE BEADED BUTYL

TAPE SEALANT

"J" SUPPORT AT

PANEL ENDS

PANEL END & CLOSURE ISOMETRIC

9

(5) FASTENERS PER

PANEL MIN.

SEALANT

Note:

- Use larger J- support for panel with clip relief, pencil ribs and striated.

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 10: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

SLR FIXED CLIP

6" X 6" BEARING PLATE

SLR METAL PANEL

CENTER CLIP-FIXED

SLR FIXED CLIP

6" X 6" BEARING PLATE

22 GA. MINIMUM

SLR METAL PANEL

10

2 FASTENERS MINIMUM

The roofing system as a floating system must have some means by which to attach it to the structure & yet not restrict its

floating ability to handle the thermal expansion/ contraction found in the system. Because of the above reasons, Morin’s

SLR panels must be positively attached at one or more purlins along a line perpendicular to the panel’s vertical rib. The

ideal location of what the panel industry calls a “fix point line” is at the center of the panel run. By having the fixed point at

this location, the amount of travel of the panel over the clip is held to a minimum. Where you have very long panel runs, it

may be required to have more then one row of fixed points. When this is necessary, then the rows should be on adjacent

rows of purlins. Refer to fixed point details in this manual for methods of installation and recommended locations.

Acceptable alternate locations for these fixed point are at either the ridge or eave of the roof. Exceptions to all of the

recommended fixed point locations may be needed because of various design restrictions such as large roof penetrations,

restraints at the ends of a panel run, an irregular shaped roof surface or at roof hip and valley locations. Panel lengths over

50' require fixed point at mid-run.

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 11: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

RIGID INSULATION (NBM)

ROOF DECK (NBM)

40 MIL ICE AND

WATER SHIELD

UNDERLAYMENT (NBM)

GUTTER STRAP

GUTTER

SUPPLEMENTAL GUTTER

SUPPORT STRAPS AS

REQUIRED 2" WIDE

SLR CLIP

SLR PANEL

LOW EAVE GUTTER ISOMETRIC-FLOATING

11

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 12: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

SLR CLIP

SLR PANEL

40 MIL ICE AND

WATER SHIELD

(NBM)

RIGID INSULATION

(NBM)

ROOF DECK

(NBM)

FASTENERS (2)

PER CLIP MIN.

EAVE TRIM

SUPPLEMENTAL

GUTTER STRAP

2" WIDE

GUTTER

GUTTER STRAP

BUTYL TUBE SEALANT

BETWEEN RIBS

AND UNDER PANEL

1"X1" DRIP ANGLE

LOW EAVE WITH GUTTER

12

Consideration during design must be given to capacity, overflow, accessibility for cleaning, and aesthetics.

Attachments must provide structural supports and allow for thermal movement. Protection from ice and snow

must be considered during the detailing of this condition. Edge of gutter should be reinforced in areas of snow or

ice accumulation. The edge of the gutter should be below the roof plane to allow for evacuation of the snow

build-up. The gutter should be independent of the roof panel as not to inhibit the thermal movement of the roof.

Floating eave requires fixed ridge.

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

1

"

m

in

.

Page 13: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

FASTENERS (2) PER CLIP MIN.

FLOATING SLR CLIP

BUTYL TUBE SEALANT

BETWEEN RIBS AND

UNDER PANEL

GUTTER FLASHING

METAL DECK (NBM)

RIGID INSULATION (NBM)

GUTTER DRAIN

"Z" CLOSURE NOTCH

AROUND RIBS IN FIELD

SEALANT AROUND

RIBS

"J" SUPPORT AT

PANEL ENDS

INTERNAL GUTTER

13

Where an exposed gutter may distract from the aesthetics of the building, an internal gutter may be required.

The condition and roof design must allow for this condition to be “fixed” against thermal movement.

Considerations must be made in areas of ice or snow to avoid blockage of the gutter or drains. Overflow

scuppers are required at each end of the gutter. This design relies on sealant to form the weather barrier.

Designers should be aware of the hazards and allow for adequate drainage. Morin requires membrane liner for

all internal gutter (NBM). Use J- support for panel with clip relief, pencil ribs and striated.

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

SLR FIXED CLIP

1" m

in.

Page 14: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

SLR CLIP

METAL DECK

(NBM)

FASTENERS

(2) PER CLIP MIN.

40 MIL ICE AND

WATER SHIELD

(NBM)

PARAPET CAP

CONTINUOUS

CLEAT

Note:

-Over flow scupper recommended at ends of gutter.

-Morin recommends use of membrane liner for all internal gutter (NBM).

GUTTER

FLASHING (NBM)

INTERNAL GUTTER AT PARAPET WALL

14

BUTYL TUBE SEALANT

BETWEEN RIBS

AND UNDER PANEL

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

1"

min

.

Page 15: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

SLR CLIP

FASTENERS (2)

PER CLIP MIN.

METAL DECK (NBM)

RIGID INSULATION (NBM)

Note:

-Over flow scupper recommended at ends of gutter.

-Morin recommends use of membrane liner for all internal gutter (NBM).

GUTTER DRAIN (NBM)

OVERFLOW SCUPPER

AT ENDWALLS

GUTTER SUPPORT (NBM)

INTERNAL GUTTER

15

BUTYL TUBE SEALANT

BETWEEN RIBS

AND UNDER PANEL

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

1

"

m

in

.

1

"

m

in

.

Page 16: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

SLR CLIP

RIDGE CAP

BEARING PLATE

FASTENERS

(2) PER CLIP MIN.

RIGID INSULATION

(NBM)

ROOF DECK (NBM)

FASTENERS

(5) PER PANEL MIN.

"Z" CLOSURE SET ON

DOUBLE BEAD BUTYL

SEALANT

SEALANT

AROUND RIBS

"J" SUPPORT AT

PANEL ENDS

HIP/RIDGE CAP - FLOATING

16

If ridge condition is required to “float”, slip joints at each side must be made to accommodate the

required expansion. Clip fasteners must be long enough to fasten into low cells of decking. Use

J- support for panel with clip relief, pencil ribs and striated.

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

4"

Page 17: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

HIP/RIDGE CAP-FIXED

FASTENERS

(5) PER PANEL MIN.

(FIXED POINT)

SEALANT

AROUND RIBS

RIDGE CAP

RIGID INSULATION

(NBM)

ROOF DECK (NBM)

FASTENERS

(2) PER CLIP MIN.

BEARING PLATE

4"

17

SUPPORT FLASHING

20 GA. MINIMUM

"Z" CLOSURE SET ON

DOUBLE BEAD BUTYL

SEALANT

BUTYL SEALANT

Note:

- Clip fasteners must be long enough to fasten into low cells of decking.

- Use J- support for panel with clip relief, pencil ribs and striated.

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

SLR CLIP

Page 18: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

VENTED RIDGE - FIXED

RIGID INSULATION

(NBM)

ROOF DECK (NBM)

BEARING

PLATE

RIDGE CAP

SLR

FIXED CLIP

V-600TE CORE-A-VENT

Note:

- Clip fasteners must be long enough to fasten into low cells of decking.

- Use J- support for panel with clip relief, pencil ribs and striated.

4"

SEALANT

AROUND RIBS

FASTENERS

(2) PER CLIP MIN.

FASTENERS

(5) PER PANEL MIN.

18

"Z" CLOSURE SET ON

DOUBLE BEAD BUTYL

SEALANT

FASTENER WITH NEOPRENE

WASHER AT 12" O.C

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 19: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

GABLE SUPPORT

RIGID INSULATION (NBM)

METAL DECK (NBM)

SLR CLIP

OPTIONS:

1) Field cut starter panel so that rake panels on both ends of roof are of same width requires field bending of cut panel

to fit under formed 18 gauge support (as shown below).

2) Start roof with full panel, insert female leg under formed 18 gauge support.

3) Use J- support for panel with clip relief, pencil ribs and striated.

#12 X

7

8

", HWH, W/W,

(DO NOT PENETRATE PANEL)

"Z" CLOSURE NOTCH

AROUND RIBS IN FIELD

SEALANT AROUND

RIBS

FASTENERS (2) PER CLIP MIN.

DOUBLE BEADED SEALANT

"J" SUPPORT AT

PANEL ENDS

FOAM BLOCK

W/ BUTYL TAPE SEALANT

HIP/ RAKE CAP

19

HIP TO RAKE

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

SLR METAL

PANEL

Page 20: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

RIGID INSULATION (NBM)

METAL DECK (NBM)

SLR CLIP

OPTIONS:

1) Field cut starter panel so that rake panels on both ends of roof are of same width requires field bending of cut panel

to fit under formed 18 gauge support (as shown below).

2) Start roof with full panel, insert female leg under formed 18 gauge support.

3) Use J- support for panel with clip relief, pencil ribs and striated.

"Z" CLOSURE NOTCH

AROUND RIBS IN FIELD

SEALANT AROUND

RIBS

FASTENERS (2) PER CLIP MIN.

DOUBLE BEADED SEALANT

"J" SUPPORT AT

PANEL ENDS

HIP/ RAKE CAP

20

HIP TO RAKE

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

SLOPE

Page 21: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

HIP/RIDGE CAP

METAL HIP/RIDGE CLOSURE SUPPLIED

10' LONG BEVEL CUT TO FIT SLOPE

DOUBLE BEADED

SEALANT

21

HIP/RIDGE ISOMETRIC

METAL CLOSURE NOTCHED AT THE

ENDS TO ACCEPT PANELS

PANEL WIDTH

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 22: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

#12 X

7

8

", HWH, W/W,

(DO NOT PENETRATE

PANEL)

FOAM BLOCK

W/ BUTYL TAPE SEALANT

RAKE TRIM

RIGID INSULATION (NBM)

ROOF DECK (NBM)

SLR PANEL

GABLE SUPPORT

BEARING PLATE

SLR PANEL CLIP

22

RAKE DETAIL

The roof and structure must be allowed to move independently of each other. Thermal movement cannot be

restricted. The gable clip is designed to allow this movement while holding down the roof panel. It will also hold

the roof panel off the structure the same distance as both hold down clips. Since the gable clip is stationary, the

gable trim piece can be attached to it for positive anchoring. The design of the gable flashing can be modified to

suit the individual project as long as the basic concept is maintained. Spacing for gable clip is 2’0” o.c. maximum.

For longer purlin spacing a gable clip trim is available in 10’0” sections.

Options:

1) Field cut starter panel so that rake panels on both ends of roof are of same width. requires field bending of cut

panel to fit under formed gable support .

2) Start roof with full panel, insert female leg under formed gable support.

3) Clip fasteners must be long enough to fasten into low cells of decking

FASTENER WITH

NEOPRENE WASHER

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 23: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

RIGID INSULATION (NBM)

ROOF DECK (NBM)

BEARING PLATE

SLR PANEL CLIP

RAKE FLASHING

BUTYL SEALANT

Note:

Clip fasteners must be long enough to fasten into low cells of decking.

SLR PANEL

RAKE DETAIL (OPTIONAL)

23

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

FASTENER WITH

NEOPRENE WASHER

Page 24: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

COMPLETE ASSEMBLY

STEP: 1

FASTEN RAKE CLEAT

STEP: 2

RAKE FLASHING

STEP: 3

2 ROWS OF CONTINUOUS

BUTYL SEALANT

STEP: 4

FIELD CUT PANEL

STEP: 5

FIELD NOTCH AND BEND

TO CREATE OPEN HEM

24

STEPPED EAVE RAKE ISOMETRIC INSTALLATION

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 25: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

RAKE FLASHING

FOAM BLOCK

W/ BUTYL SEALANT

FASTENERS (2) PER CLIP MIN.

RIGID INSULATION (NBM)

METAL DECK (NBM)

METAL WALL

RAKE FLASHING

FLASHING

#12 X

7

8

", HWH, W/W,

(DO NOT PENETRATE PANEL)

SLR METAL PANEL

SLR CLIP

GABLE SUPPORT

6"X6"

BEARING PLATE

25

WALL TO RAKE FLASHING

Since the width of the standing seam

roof can vary due to compression or

spreading during the installation, the

module can be altered to minimize

the endwall trim width. In cases of

fixed panel width or module, the

designer should center the roof

panels if possible, to reduce the

width of the trim pieces.

The endwall flash should be sloped

to allow drainage of water to avoid

leaks at joints in the trim. Reinforcing

of the trim may be required at large

widths to support the joints.

URETHANE SEALANT

BETWEEN FLASHING

AND MASONRY

12

1

4

" MIN.

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 26: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

RIGID INSULATION (NBM)

METAL DECK (NBM)

FASTENERS (2)

PER CLIP MIN.

SLR CLIP

BUTYL TUBE SEALANT BETWEEN

RIBS AND UNDER PANEL

TRANSITION FLASHING

SLR CLIP

6" X 6" BEARING PLATE

3

8

" SUPPORT (NBM)

ALIGN FACE OF TRIM WITH

CONTINUOUS RAKE CLIP AND

STEP RAKE FLASHING

RAKE AT SLOPING TO FLAT ROOF (FLOATING)

26

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 27: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

THROUGH-WALL FLASHING

STEP RAKE FLASHING

MASONRY BLOCK (NBM)

SLR METAL PANEL

SLR METAL

PANEL CLIP

GABLE SUPPORT

FASTENERS (2) PER CLIP MIN.

RIGID INSULATION (NBM)

METAL DECK (NBM)

#12 X

7

8

", HWH, W/W,

(DO NOT PENETRATE THRU THE PANEL)

SLR METAL PANEL

FOAM BLOCK

W/ BUTYL SEALANT

27

WALL TO RAKE STEP FLASHING

6" X 6" BEARING PLATE

MASONRY FASTENER

URETHANE SEALANT

BETWEEN FLASHING AND MASONRY

12

1

2

" MIN.

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 28: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

METAL DECK (NBM)

#12 X

7

8

", HWH, W/W,

(DO NOT PENETRATE PANEL)

RIGID INSULATION (NBM)

COMPRESSIBLE INSULATION

(NBM)

1" 1" 1"

FOAM BLOCK

W/ BUTYL SEALANT

GABLE SUPPORT

THROUGH-WALL

FLASHING

RAKE FLASHING

28

WALL TO RAKE EXPANSION JOINT

6"X6" BEARING PLATE

URETHANE SEALANT

BETWEEN FLASHING

AND MASONRY

OPTIONS:

1) Field cut starter panel so that rake panels on both ends of roof are of same width requires field bending of

cut panel to fit under continuous rake clip (as shown below).

2) start roof with full panel, insert female leg under continuous rake clip.

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

*NBM = Not By Morin

Page 29: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

METAL DECK (NBM)

RIGID INSULATION (NBM)

1" 1" 1"

#12 X

7

8

", HWH, W/W,

(DO NOT PENETRATE PANEL)

FOAM BLOCK

W/ BUTYL SEALANT

SLR METAL PANEL

CONTINUOUS GABLE SUPPORT

BUTYL TUBE SEALANT ON

TOP OF GABLE SUPPORT

29

PANEL EXPANSION JOINT

Some building designs require an expansion joint to accommodate movement of the structure. The detail must

be designed to allow movement in the anticipated directions. Several proprietary products are available which

can be integrated into this basic design.

Options:

1) Field cut starter panel so that rake panels on both ends of roof are of same width. Requires field bending of

cut panel to fit under gable support (as shown below).

2) Start roof with full panel, insert female leg under gable support.

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 30: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

VALLEY FLASHING

EAVE CLEAT

1

8

"X1" CONTINUOUS

TAPE SEALANT

20 GA. SUB-PLATE

SLR METAL PANEL

30

RAKE @ VALLEY (FLOATING)

#10 X 1" TEK. WAFER

HEAD FASTENERS

AT 6" O.C.

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

4" OF SEALANT IN

STIFFENING RIBS

Page 31: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

SLR CLIP

BUTYL TUBE SEALANT

BETWEEN RIBS

AND UNDER PANEL

RIGID INSULATION (NBM)

METAL DECK (NBM)

VALLEY

FLASHING

FASTENERS (2)

PER CLIP MIN.

S

A

M

E

H

T

.

A

S

P

A

N

E

L

L

A

R

G

E

R

A

T

L

O

W

S

L

O

P

E

20 GA. SUB-PLATE

FASTENERS 6" O.C

SLR METAL

PANEL

31

RAKE AT VALLEY FLOATING

6

"

M

I

N

.

Valley flashing must allow for sufficient area to carry anticipated runoff without overflow or backup under the roof

edge. The raised center assists in diversion of water and allows for thermal movement. Floating valley requires

fixed hip/ ridge.

1

8

" X 1" CONTINUOUS

DOUBLE BEAD

BUTYL TAPE SEALANT

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 32: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

12" M

IN

BA

CK

P

AN

B B

C

D

C

D

32

CU

RB

LE

NG

TH

6"

EQUIPMENT CURB FLASHING PLAN VIEW

5"

AP

RO

N

Large openings for equipment or hatchways require a curb with means of diverting the water around the

opening. Set and secure roof curb on support framing. At least two parallel curb walls must be on support

framing. In high load areas engineer needs to check for proper support. Loads shall not be supported by

cantilever sections exceeding 1’0” in length. Cut roof panels to fit snugly around curb walls and to within 1” of the

water diverter. Apply a wide band of tape caulk to the top side of curb flanges. Install and seal closures in ends

of panels. Plug and caulk all rib ends. Press roof panels into place. Fasten roof panels through curb flanges to

support steel using suitable fasteners for the roof system. A spacing of approximately 3” should

be used. Inspect installation and fasteners. Apply an exterior sealant to seal seams around all sides of curb to

insure a weathertight seal. In all cases the curb assembly is capped by a collar or skirt that extends down over

the curb. Curb to be fixed to panel only. Allowance must be made at equipment curb and trim to allow for thermal

movement.

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 33: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

SIDE FLASHING

BACK PAN

CURB PENETRATION

33

EQUIPMENT CURB FLASHING

BACK PAN

APRON

SIDE FLASHING

1" TABS

CU

RB

HE

IG

HT

1

2

"

M

I

N

.

1

1

2

"

V

A

R

I

E

S

CU

RB

HE

IG

HT

C

U

R

B

L

E

N

G

T

H

CU

RB

HE

IG

HT

5

"

2"

1

2

"

M

I

N

.

1" TABS

5

"

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 34: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

CURB CAP (NBM)

FASTENERS (2) PER CLIP MIN.

METAL DECK (NBM)

RIGID INSULATION (NBM)

6" minimum

TRANSITION FLASHING

34

EQUIPMENT CURB - SECTION B

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

18 GA GALVANIZED

CAP (NBM)

Page 35: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

FASTENERS (2) PER CLIP MIN.

METAL DECK (NBM)

RIGID INSULATION (NBM)

BUTYL TUBE

SEALANT

SLR CLIP

6"-10" M

A

X

IM

U

M

DOUBLE BEAD CONTINUOUS

1

8

" x1" BUTYL TAPE SEALANT

18 GA GALVANIZED

CAP (NBM)

35

EQUIPMENT CURB - SECTION C

CURB CAP (NBM)

BUTYL TAPE

SEALANT

BACK PAN

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 36: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

CURB CAP (NBM)

FASTENERS (2) PER CLIP MIN.

METAL DECK (NBM)

RIGID INSULATION (NBM)

18 GA GALVANIZED

CAP (NBM)

APRON

SLR CLIP

1" MIN.

SEALANT

AROUND RIBS

"Z" CLOSURE

NOTCH AROUND RIBS IN FIELD

DOUBLE BEAD

1

8

"X1"

BUTYL TAPE SEALANT

"J" SUPPORT AT

PANEL ENDS

36

EQUIPMENT CURB - SECTION D

*NBM = Not By Morin

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 37: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

#14 X

7

8

", TEK 3, HWH, W/W,

PAINTED 2" O.C.

BEFORE INSTALLING THE DEKTITE,

PLACE CONTINUOUS BEAD OF

SEALANT AROUND PIPE AT HEIGHT

OF BOOT TOP

STAINLESS STEEL

PIPE CLAMP

APPLY SEALANT BETWEEN BOTTOM

OF DEKTITE AND TOP OF PANEL

37

PIPE PENETRATION DETAIL

Notes:

1) Attach dektite to panel only to allow thermal movement.

2) Center pipe penetration within panel width if possible.

3) Keep base of dektite away from panel edges (minimum 2").

4) Provide 1" clearance between edge of pipe and panel hole.

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 38: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

6"

1

8

" GAP

GUTTER SPLICE PLATE

GUTTER LAP DETAIL

4"

2" 1"1"

1" LAP

GUTTER EXPANSION DETAIL

38

GUTTER FLASHING CONDITIONS

3

4

" 1

1

2

"

END CAP

END CAP

END CAP

4

"

GUTTER EXPANSION DETAIL

3

4

"

EXPANSION

COVER

SET IN SEALANT

Note: Use expansion joint every 25'

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 39: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

4"

RAKE LAP DETAIL

6

"

L

A

P

4"

EAVE LAP DETAIL

EAVE INSIDE SPLICE PLATE

4

"

N

O

T

C

H

NOTCH IN BOTTOM LEG

39

RAKE AND EAVE FLASHING CONDITION

Note: Shingle laps in direction

of water flow.

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

6"

4

"

N

O

T

C

H

NOTCH IN BOTTOM LEG

SPLICE PLATE

Page 40: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

6"

RIDGE CAP - LAP DETAIL

6"

HIP CAP - LAP DETAIL

6

"

L

A

P

W

A

T

E

R

F

L

O

W

BUTYL SEALANT

BUTYL SEALANT

6" NOTCH IN

THE BOTTOM LEG

TYP. LAP DETAIL

40

RIDGE AND HIP FLASHING CONDITION

6

"

L

A

P

FASTEN PANEL CLOSURE

TO PANEL CLOSURE TO

FIX IN PLACE

Note: Field Notch Hems As Required.

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 41: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

DOWN SPOUT OUTLET

CENTER HEM

TYPICAL 4" X 3" ELBOW

DIMENSIONS WITH 6"

RETURN

41

DOWNSPOUT

4"

3"

4"

3"

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

Page 42: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

KNEE CAP

PART A

MALE SIDE

OF THE PANEL

BUTYL TUBE SEALANT

6

"

NOTES:

- Adjacent clip must be fixed condition caulk all edges around splice plate.

- All dimensions are nominal.

- Fabricate trim to fit inside and outside of panel seam as req'd.

STEP 1

STEP 2

STEP 3

COMPLETED SET

BUTYL SEALANT

(SEE BELOW)

PART B

42

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

KNEE DEATAIL

F.S

F.S

Page 43: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

SIDE VIEW

ASSEMBLY

SNOW GUARD

2" STRIP OF MATCHED

GAUGE & COLOR STRIP

SLR METAL PANEL

1

2

"

M

I

N

CROSS MEMBER CONTINUOUS

43

SNOW GUARD

S

L

O

P

E

Note:

1) Mount S-5 clamp directly to top of panel rib with set screw.

2) Install 2" color strip from panel flatstock into snow guard.

3) Connect clip to snow guard, one per panel, centered.

4) Connect assembly to s-5-z clamps.

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501

S-5 CLAMP

SLR PANEL CLIP

Page 44: UNDERLAYMENT (NBM)...MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501 10 2 17 42 4 5 13 12 22 23 34 36 36 15 7 11 20 BUTYL TUBE SEALANT RIGID INSULATION (NBM)

LIGHTNING ROD AIR TERMINAL

CONDUCTOR CABLE

S-5-U CLAMP

ALUMINUM TOP MOUNT

SIDE VIEW

SECTION CUT VIEW

CONDUCTOR CABLE

ALUMINUM TOP MOUNT

CLAMP

SLR PANEL

44

LIGHTNING PROTECTION

Note:

-Coat cables and clamp with bituminous.

-Coating as necessary to prevent galvanic reaction.

MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501MORINCORP.COM * BRISTOL, CT * FONTANA, CA * DELAND, FL * T: 800-640-9501