    f Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment. Some of theparts may also have elevated operating temperatures.

    Non-observance of these conditions and the safety instructions can result in personal injury or in prop-erty damage.

    Therefore, only trained and qualified personnel may install and maintain the system.

    The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to complywith the applicable safety standards.

    The same text in German:Wichtiger Hinweis zur Produktsicherheit

    In elektrischen Anlagen stehen zwangslufig bestimmte Teile der Gerte unter Spannung. Einige Teileknnen auch eine hohe Betriebstemperatur aufweisen.

    Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Krperverletzungen undSachschden fhren.

    Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertesPersonal die Anlagen installiert undwartet.

    Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Gertemssen die zutreffenden Sicherheitsbestimmungen erfllen.

    Trademarks:

    All designations used in this document can be trademarks, the use of which by third parties for theirown purposes could violate the rights of their owners.

    Copyright (C) Siemens AG 2002.

    Issued by the Information and Communication Networks GroupHofmannstrae 51D-81359 Mnchen

    Technical modifications possible.Technical specifications and features are binding only insofar as

    they are specifically and expressly agreed upon in a written contract.

  • 8/12/2019 UMN CMXC c800_1_7619

    3/152

    A50010-A3-C800-1-7619 3

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    This document consists of a total of 152 pages. All pages are issue 1.

    Contents

    1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111.1 Structure of the Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111.2 Typographical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111.3 Additional Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.4 Protective Measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131.4.1 General Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131.4.2 Protection Against Excessive High Contact Voltages. . . . . . . . . . . . . . . . . 131.4.3 Components Subject to Electrostatic Discharge. . . . . . . . . . . . . . . . . . . . . 131.4.4 Handling Modules (General) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141.4.5 Virus Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141.5 CE Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    1.6 Environmental Passport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    2 System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172.1 Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172.2 Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192.2.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192.2.2 External Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192.2.3 Internal Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212.2.4 Clock Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232.2.5 Conferences. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.2.6 Subrate Multiplexer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    2.2.7 Voice Channel in Common Frequency Radio Networks. . . . . . . . . . . . . . . 252.2.8 Redundancy Concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252.2.9 Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262.3 Operation and Supervision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272.3.1 Access to CMXC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272.3.2 Operating Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272.3.3 Supervision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272.3.4 Diagnostic Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.4 Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.4.1 Storage Structure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.4.2 Initializing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

    3 Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293.2 SNUS Shelf. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303.2.1 SNUS Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303.2.2 Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323.2.3 QD2 Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333.2.4 Position and Assignment of Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . 343.2.5 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403.3 Central Unit CUC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403.3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403.3.2 Supervision and Alarm Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

  • 8/12/2019 UMN CMXC c800_1_7619

    4/152

    4 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    3.3.3 Operating Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 503.3.4 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 533.4 Interface Unit PU16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

    3.4.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 543.4.2 Supervision and Alarm Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 563.4.3 Operating Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 613.4.4 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643.5 Supervision Unit SUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643.5.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643.5.2 Supervision and Alarm Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673.5.3 Operating Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 683.5.4 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

    4 Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 784.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 784.1.1 Scope of the ITMN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 784.1.2 Error Reports on the Installation Test Manual. . . . . . . . . . . . . . . . . . . . . . . 784.1.3 Dealing with Defective Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 784.1.4 Procedure in the Event of Faults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 784.1.5 Procedure in the Event of Serious Faults. . . . . . . . . . . . . . . . . . . . . . . . . . . 784.2 Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 794.2.1 Hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 794.2.2 Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 794.3 Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804.3.1 Sequences for Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

    4.3.2 Visually Inspection (Check List) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804.3.3 Starting the LCT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 814.3.4 Commissioning of the SNUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 814.3.5 Commissioning of the SUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 824.3.6 Commissioning the CUC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 844.3.7 Commissioning the PU16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 864.3.8 Creating the Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

    5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 915.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 915.1.1 Notes for Working . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

    5.1.2 Overview of Operating Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 915.1.3 Overview of Function Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 975.1.4 Network Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 985.1.5 SISA Communication Network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 995.1.6 Interfaces used for Operating Purposes . . . . . . . . . . . . . . . . . . . . . . . . . . 1015.2 Software Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1025.3 Configuration Management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1025.3.1 SISA-V/LMXV2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1035.3.2 CUC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1045.3.3 PU16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1115.4 Crossconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117

    5.4.1 Crossconnections 2 Mbit/s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117

  • 8/12/2019 UMN CMXC c800_1_7619

    5/152

    A50010-A3-C800-1-7619 5

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    5.4.2 Cross Connections 64 kbit/s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1255.4.3 Cross Connections 8 kbit/s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1315.4.4 Conference Mode (between 64 kbit/s Time Slots only) . . . . . . . . . . . . . . 135

    5.4.5 Displaying the used 2-Mbit/s Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1405.4.6 Overview of the used 64 kbit/s Crossconnections . . . . . . . . . . . . . . . . . . 142

    6 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1446.1 Operator Terminals for Maintenance and Fault Rectification. . . . . . . . . . 1446.2 Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1446.2.1 Hardware Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1456.2.2 Software Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1456.2.3 Adjustments for Service in System Module . . . . . . . . . . . . . . . . . . . . . . . 1456.2.4 Fault Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1456.3 Representation of Alarms in OS and LCT. . . . . . . . . . . . . . . . . . . . . . . . . 1456.4 Elimination of an Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1466.4.1 Localization of an Alarm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1466.4.2 Alarm Elimination by Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1476.4.3 Branch to Maintenance Procedures from Alarm Lists of the ACI. . . . . . . 1476.5 Branch to Maintenance Procedure from Graphical User Interface of the

    OS/LCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1476.6 Explanations of the Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1476.7 Alarm Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148

    7 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150

    8 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151

  • 8/12/2019 UMN CMXC c800_1_7619

    6/152

    6 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    Illustrations

    Fig. 1.1 ESD Symbol. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    Fig. 2.1 CMXC Application (Example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

    Fig. 2.2 CMXC Application in an FMX2R3.1 Ring Connection . . . . . . . . . . . . . . 18

    Fig. 2.3 CMXC Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    Fig. 2.4 Allocation of Alarm Contacts, Example ZA(A) . . . . . . . . . . . . . . . . . . . . 20

    Fig. 2.5 CMXC Synchronization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

    Fig. 2.6 Redundancy Concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    Fig. 2.7 Power Supply in Shelf SNUS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

    Fig. 2.8 CMXC in Stand-alone Operation Mode (Example) . . . . . . . . . . . . . . . . . 27

    Fig. 3.1 SNUS with Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

    Fig. 3.2 SNUS Front View with the DIL Switches S101 to S116. . . . . . . . . . . . . 31

    Fig. 3.3 DIL Switches S105 to S116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    Fig. 3.4 DIL Switch S101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

    Fig. 3.5 DIL Switches S103 and S104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

    Fig. 3.6 Location of Connectors and Equipping of Units. . . . . . . . . . . . . . . . . . . 34

    Fig. 3.7 CUC Block Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

    Fig. 3.8 CUC Operating Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

    Fig. 3.9 Position of the Jumpers on the Pin Strips X401. . . . . . . . . . . . . . . . . . . 50

    Fig. 3.10 PU16 Block Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

    Fig. 3.11 Local Loop and Remote Loop Test Loops . . . . . . . . . . . . . . . . . . . . . . . 57

    Fig. 3.12 PU16 Operating Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

    Fig. 3.13 Position of the Jumpers on the Pin Strips. . . . . . . . . . . . . . . . . . . . . . . . 62

    Fig. 3.14 Operation and Supervision of the System Modules inStandalone Operation Mode with the SUE (Example) . . . . . . . . . . . . . . 65

    Fig. 3.15 SUE Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

    Fig. 3.16 SUE in a Line Network Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

    Fig. 3.17 SUE Operating Elements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

    Fig. 3.18 SUE Terminal Assignment 12 (F Interface) . . . . . . . . . . . . . . . . . . . . . . 71

    Fig. 3.19 SUE Connector Assignment 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

    Fig. 3.20 Connector Assignment 10 of the SUE . . . . . . . . . . . . . . . . . . . . . . . . . . 73

    Fig. 4.1 SUE Dialog Software Download. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

    Fig. 4.2 SUE Dialog Equipment Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

    Fig. 4.3 SUE Dialog Alarms of SISA-V/LMXV2#... . . . . . . . . . . . . . . . . . . . . . . 84

    Fig. 5.1 QD2 Structure (Example). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

    Fig. 5.2 SISA Structure of FastLink System. . . . . . . . . . . . . . . . . . . . . . . . . . . . 100

    Fig. 5.3 Example of a SUE Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

    Fig. 5.4 SUE Register Card Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103

    Fig. 5.5 CUC Register Card for Setting the Clock Synchronization . . . . . . . . . . 105

    Fig. 5.6 CUC Register Card for Configuring the Alarm Supervision . . . . . . . . . 106

    Fig. 5.7 CUC Register Card for Configuring the Ports . . . . . . . . . . . . . . . . . . . . 107

    Fig. 5.8 CUC Register Card for Setting the ECC Operation Mode . . . . . . . . . . 108

    Fig. 5.9 CUC Register Card for Activation/Deactivation of the ports . . . . . . . . . 109

    Fig. 5.10 CUC Register Card for Displaying the State of the ECC Ports. . . . . . . 110

  • 8/12/2019 UMN CMXC c800_1_7619

    7/152

    A50010-A3-C800-1-7619 7

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    Fig. 5.11 CUC Register Card for Displaying the State of the PCI Ports . . . . . . . 111

    Fig. 5.12 PU16 Register Card for setting the Operator Loop. . . . . . . . . . . . . . . 112

    Fig. 5.13 PU16 Register Card for Setting the Alarm Criteria . . . . . . . . . . . . . . . 113

    Fig. 5.14 PU16 Register Card for Setting the Frame structure . . . . . . . . . . . . . . 113Fig. 5.15 PU16 Register Card for Setting the Sa Bit Control . . . . . . . . . . . . . . . 114

    Fig. 5.16 PU16 Register Card for Setting the Operation Mode. . . . . . . . . . . . . . 115

    Fig. 5.17 PU16 Register Card for Displaying the State off all Ports. . . . . . . . . . 115

    Fig. 5.18 Register Card Connections 2Mbit/s. . . . . . . . . . . . . . . . . . . . . . . . . . 117

    Fig. 5.19 Register Card for Setting Filter Parameter. . . . . . . . . . . . . . . . . . . . . . 120

    Fig. 5.20 Dialog for Creating Crossconnection 2 Mbit/s(Example with Filter setting Representation of Resources: FG-FE) . 121

    Fig. 5.21 Dialog for Setting the Time Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122

    Fig. 5.22 Dialog for Setting the Switching Criteria . . . . . . . . . . . . . . . . . . . . . . . 122

    Fig. 5.23 Register Card Connections 64kbit/s . . . . . . . . . . . . . . . . . . . . . . . . . 125Fig. 5.24 Dialog for Creating the Crossconnection 64 kbit/s

    (Example with Filter setting Representation of Resources; FG-FE) . 128

    Fig. 5.25 Displaying of the Time Slots assigned to a Group (Example). . . . . . . 129

    Fig. 5.26 Dialog for Creating the Crossconnection 64 kbit/s(Example with Filter settingRepresentation of Resources; Module-Port-TS) . . . . . . . . . . . . . . . . 130

    Fig. 5.27 Register Card Connections 8kbit/s. . . . . . . . . . . . . . . . . . . . . . . . . . 131

    Fig. 5.28 Dialog for Creating the Crossconnection 8 kbit/s(Example with Filter setting Representation of Resources; FG-FE) . 134

    Fig. 5.29 Dialog Configure Conferences - CMXII-CAS (Example) . . . . . . . . . . 136

    Fig. 5.30 Dialog Add data Conference - CMXC#...:CUC#... . . . . . . . . . . . . . . 138

    Fig. 5.31 Register Card 2Mbps Port Usage (Example) . . . . . . . . . . . . . . . . . . 140

    Fig. 5.32 Register Card 64Kbps CC Overview (Example). . . . . . . . . . . . . . . . 142

    Fig. 6.1 Elements of the Maintenance Procedures. . . . . . . . . . . . . . . . . . . . . . 148

  • 8/12/2019 UMN CMXC c800_1_7619

    8/152

    8 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    Tables

    Tab. 1.1 Typographical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

    Tab. 2.1 Structure of a PCI Time Slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    Tab. 2.2 PCI Frame Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    Tab. 2.3 Conference Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

    Tab. 3.1 SNUS Overview of Addressing and the Units. . . . . . . . . . . . . . . . . . . . . 32

    Tab. 3.2 Assignment of Connectors X141 (left and ) X142 (right) . . . . . . . . . . . . 35

    Tab. 3.3 Terminal Assignment of Jacks X101, X102 and X121. . . . . . . . . . . . . . 35

    Tab. 3.4 Terminal Assignment of 9-Contact Jacks X143 and X144. . . . . . . . . . . 36

    Tab. 3.5 Terminal Assignment of Jacks X122 and X131 . . . . . . . . . . . . . . . . . . . 37

    Tab. 3.6 Terminal Assignment of Jacks X109, X110, X 113, X114, X129, X130,X133, X134 and X115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

    Tab. 3.7 CUC Signaling the active Operating Mode . . . . . . . . . . . . . . . . . . . . . . . 42

    Tab. 3.8 CMXC Indication of the Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . 43Tab. 3.9 CUC Indication of the standby Operating Mode . . . . . . . . . . . . . . . . . . . 43

    Tab. 3.10 CUC Alarm Table (active) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

    Tab. 3.11 CUC Alarm Table (standby). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

    Tab. 3.12 CUC Connector (bottom) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

    Tab. 3.13 CUC Connector (top) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

    Tab. 3.14 PU16 Signaling the Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

    Tab. 3.15 PU16 Alarm Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

    Tab. 3.16 PU16 Connector (bottom). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

    Tab. 3.17 PU16 Connector (top) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

    Tab. 3.18 SUE LED Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

    Tab. 3.19 Settings on Switches S1 and S2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

    Tab. 3.20 Settings on Switch S3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

    Tab. 3.21 Configuration of the T Interfaces (Switch S4) . . . . . . . . . . . . . . . . . . . . . 69

    Tab. 3.22 ECC Configuration (Switch S4). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

    Tab. 3.23 Assignment on Test Jack X4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

    Tab. 3.24 Assignment on Test Jack X5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

    Tab. 4.1 Pin Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

    Tab. 4.2 Sequence of the Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

    Tab. 4.3 Shelf Equipping with SUE and Units for CMXC. . . . . . . . . . . . . . . . . . . 81

    Tab. 4.4 Sequence for Creating 2-Mbit/s Cross Connections. . . . . . . . . . . . . . . . 88

    Tab. 4.5 Sequence for Creating 64-kbit/s Cross Connections . . . . . . . . . . . . . . . 89

    Tab. 4.6 Sequence for Creating 8-kbit/s Cross Connections. . . . . . . . . . . . . . . . 89

    Tab. 4.7 Sequence for Creating Conferences. . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

    Tab. 5.1 Overview of Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

    Tab. 5.2 Network Element CMXC and its associated Function Groups. . . . . . . . 97

    Tab. 5.3 Name of the Function Groups. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

    Tab. 5.4 F Interface of the System Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

    Tab. 5.5 Correlation between Unit and Load Files. . . . . . . . . . . . . . . . . . . . . . . 102

    Tab. 5.6 Configuration Parameters for the Network Elements. . . . . . . . . . . . . . 103

    Tab. 5.7 List Entries in the Clock Priority List. . . . . . . . . . . . . . . . . . . . . . . . . . . 105

  • 8/12/2019 UMN CMXC c800_1_7619

    9/152

    A50010-A3-C800-1-7619 9

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    Tab. 5.8 Explanation of the Buttons in the CUC Register Card Clock sync. . . 106

    Tab. 5.9 Explanation of the CUC Register Card ECC Alarm Criteria . . . . . . . 106

    Tab. 5.10 Explanation of the CUC Register Card Frame . . . . . . . . . . . . . . . . . 107

    Tab. 5.11 Explanation of the CUC Register Card ECC Mode . . . . . . . . . . . . . . 108Tab. 5.12 Explanation of the CUC Register Card General . . . . . . . . . . . . . . . . 109

    Tab. 5.13 Explanation of the CUC Register Card ECC Status . . . . . . . . . . . . . 110

    Tab. 5.14 Explanation of the CUC Register Card PCI Status. . . . . . . . . . . . . . 111

    Tab. 5.15 Explanation of the PU16 Register Card General. . . . . . . . . . . . . . . . 112

    Tab. 5.16 Explanation of the Pu16 Register Card Alarm Criteria . . . . . . . . . . . 113

    Tab. 5.17 Explanation of the PU16 Register Card Frame . . . . . . . . . . . . . . . . . 114

    Tab. 5.18 Explanation of the PU16 Register Card Clock Control . . . . . . . . . . . 114

    Tab. 5.19 Explanation of the PU16 Register Card General. . . . . . . . . . . . . . . . 115

    Tab. 5.20 Explanation of the PU16 Register Card Status View. . . . . . . . . . . . . 116

    Tab. 5.21 Explanation of the Register Card Connections 2Mbit/s . . . . . . . . . . . 117Tab. 5.22 Explanation of the Buttons on the Register Card

    Connections 2Mbit/s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118

    Tab. 5.23 Switchable Function Groups for 2Mbit/s Cross Connections. . . . . . . . 123

    Tab. 5.24 Assignment of IPMB64/2 to Associate TP . . . . . . . . . . . . . . . . . . . . . . 123

    Tab. 5.25 Explanation of the Register Card Connections 64kbit/s . . . . . . . . . . 125

    Tab. 5.26 Explanation of the Buttons on the Register CardConnections 64kbit/s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126

    Tab. 5.27 Switchable Function Groups for 64kbit/s Crossconnections. . . . . . . . 129

    Tab. 5.28 Explanation of the Register Card Connections 8kbit/s . . . . . . . . . . . 131

    Tab. 5.29 Explanation of the Buttons on the Register CardConnections 8kbit/s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132

    Tab. 5.30 Switchable Function Groups for 8kbit/s Cross Connections . . . . . . . . 135

    Tab. 5.31 Explanation of the Register Card Data Conferences. . . . . . . . . . . . . 136

    Tab. 5.32 Explanation of the Buttonson the Register Card Data Conferences . . . . . . . . . . . . . . . . . . . . . . 137

    Tab. 5.33 Explanation of the Register Card 2Mbps Port Usage. . . . . . . . . . . . 140

    Tab. 5.34 Explanation of the Buttons on the Register Card2Mbps Port Usage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141

    Tab. 5.35 Explanation of the Register Card 64Kbps CC Overview . . . . . . . . . . 142

    Tab. 5.36 Explanation of the button on the Register Card64Kbps CC Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143

    Tab. 6.1 Determining the TOS Address from the DCN Alarm Address . . . . . . . 147

    Tab. 6.2 Alarm Association . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148

  • 8/12/2019 UMN CMXC c800_1_7619

    10/152

    10 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

  • 8/12/2019 UMN CMXC c800_1_7619

    11/152

    A50010-A3-C800-1-7619 11

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    1 IntroductionIn this Manual, an overview about the components and their interworking in the accessnetwork of the Crossconnect Multiplexer CMXC is given. Function, commissioning,operation and maintenance are described in detail. The operation is done via the graph-ical interface of the Operating System (OS). This is the Domain Manager ACI Softwareup version 8.2. For the ACI DM V8.2, there is a separate documentation available (seeSection 1.3 "Additional Documentation").

    1.1 Structure of the Manual

    The manual consists of the following Sections: Introduction System overview Components

    Commissioning Operation Maintenance and trouble shouting.

    Technical Description The Technical Description (system overview and components) contains special infor-mation about the CMXCs Modules and the shelf, i. e. interfaces, Technical Data and theconnector assignment.

    Commissioning The Commissioning describes all the procedures and measurements for activating theinstalled system, including step-by-step instructions to commissioning the SystemModule CMXC.

    Operation This section offers a guide line to use the operating procedures for configuring and for

    creating the crossconnections.Maintenance The procedures which expedite the re-establishment of normal operating state after a

    malfunction has occurred in the CMXC can be find out via the operating system byBranch to Maintenance. The section Maintenance gives an overview of the possiblemalfunctions and contains a guideline for the using of Branch to Maintenance.

    1.2 Typographical Conventions

    In all sections of this manual, the following conventions are applied:

    Style of Representation Meaning

    Courier Inputs and outputsExample: EnterLOCALas the server name

    Command not found

    Italics Variables

    Example: namecan be up to eight letters long.

    Italics Variables fin procedures and title bas

    Example: General NE Parameter. :CUC#...

    Boldface Special emphasis

    Example: This name may notbe deleted

    Tab. 1.1 Typographical Conventions

  • 8/12/2019 UMN CMXC c800_1_7619

    12/152

    12 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    1.3 Additional Documentation

    In addition, following documentation are used: User Manual AccessIntegrator ACI DM version V8.2, UMN

    SIEMENS Kit No. A50010-T3-A808 User Manual Flexible Multiplexer FMX2R3.1, UMN

    SIEMENS Ordering No. A50010-A3-C700-*-7619. Project (planning) documentation.

    Quotation marks Labels on the user interface (e.g. windows, menu items, buttons)

    Example: Activate the OK button

    Make a selection in the File menu.

    Key combinations

    Example: +

    Successive menu items

    Example: FileClose

    iAdditional items of information

    !Warnings at critical points in the activity sequence

    Style of Representation Meaning

    Tab. 1.1 Typographical Conventions (Cont.)

  • 8/12/2019 UMN CMXC c800_1_7619

    13/152

    A50010-A3-C800-1-7619 13

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    1.4 Protective Measures

    1.4.1 General Notes

    This section contains a summary of the most important requirements with regard to pro-tection of people and equipment. It does not claim to be complete. The installation in-structions listed are shown in detail in the relevant Installation Manuals.

    All assembly, installation, operation and repair work may only be undertaken by properlytrained and qualified personnel.In the event of any injury (e.g. burns and acid burns) being sustained, seek medical helpimmediately.

    1.4.2 Protection Against Excessive High Contact Voltages

    When handling the power supply or working on it, observe the safety measures de-scribed in the specifications of the European Norm EN 50110, part 1 and part 2 (Oper-ation of electrical Systems) and the valid national country specific standards.

    1.4.3 Components Subject to Electrostatic Discharge

    Fig. 1.1 ESD Symbol

    When packing or unpacking, touching pulling or plugging plug-in units bearing the ESDsymbol, it is essential to wear a grounding bracelet, which should be grounded to an rackor shelter when working on it. This ensures that the units are not subject to electrostaticdischarge.

    Under no circumstances should the printed conductors or components of modules betouched. Take hold of modules by the edge only.

    Once they have been removed, modules must be placed in the conductive plasticsleeves intended for them, and kept or dispatched in the special boxes or transport cas-

    es bearing the ESD symbol.In order to avoid further damage to defective modules, they should be treated with thesame degree of care as new ones.

    Modules which are accommodated in a closed and intact housing are protected anyway.

    European standard EN50082-1 provides information on the proper handling of compo-nents which are subject to electrostatic discharge.

    !Slide-in units bearing the symbol in Fig. 1.1, are equipped with components subject toelectrostatic discharge, that is to say the relevant safety provisions must be adhered to.

  • 8/12/2019 UMN CMXC c800_1_7619

    14/152

  • 8/12/2019 UMN CMXC c800_1_7619

    15/152

    A50010-A3-C800-1-7619 15

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    1.6 Environmental Passport

    The aim of this environmental passport is to provide you with the most important envi-ronmentally-relevant information for this product. This means you can be sure that you

    have selected a supplier who develops, produces, packs and ships their products in anenvironmentally-compatible way.

    Product origination process

    Even at the product origination stage we pursue the aim of minimizing the adverse ef-fects on the environment: We systematically record all product-related environmental requirements and take

    account of these both in the product definition and in its development. Protecting the environment is a matter of course in our day-to-day work. This in-

    cludes minimizing the consumption of paper by using the latest technologies (e.g.Internet, e-mail, database, 4:1 paper printouts) as well as multi-separation, heat in-

    sulation and intelligent use of energy. We coordinate all environmental activities via a certified environmental manage-ment system which complies with ISO 14001. It is checked in accordance with theGerman certification body DQS (Deutsche Gesellschaft fr Zertifizierung von Man-agementsystemen mbH), quality and environment assessors. Certificate registra-tion No.: 66749-01.

    Naturally we at Siemens are conscious of the fact that expenditure for environmentalprotection measures must be kept within an economically justifiable framework. After all,we still want to offer you this product with a price/performance ratio which is attractiveto you.

    Manufacturing

    Production facilities are equipped with the very latest, environmentally-friendly produc-tion machinery. Because of their minimal adverse effects on the environment theseplants can be operated without the need for special permits or notification. However theappropriate measures for reducing emissions are still taken in accordance with the stateof the art: Solder systems with condensate traps minimize both the deposition of solvents at

    the workstation and emissions into the atmosphere Our manufacturing processes are completely free of CFCs, volatile CHCs (chlorinat-

    ed solvents) and toxic substances. The heat generated from producing compressed air will be used for heating walkable

    floor surfaces. Module production is practically waste-water-free since the use of low-residue fluxes

    obviates the need for cleaning processes. Far more than three quarters of all production waste is fed back into the secondary

    resources cycle. Only 0.5% of the production waste has to be disposed of as specialwaste.

    Transport/shipping

    The systems made by our company are shipped exclusively in environmentally-friendlypackaging: pesticide-free wooden packing cases, collapsible, reusable Cardboard boxes

    Filling/stuffing: air cushions with polyethylene envelope

  • 8/12/2019 UMN CMXC c800_1_7619

    16/152

    16 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    The Green Dot symbol for all packing for private end customers as a sign of ourinvolvement in Germanys dual system.

    Energy consumption

    The ever greater level of integration in components has significantly reduced the energyconsumption of the systems without affecting the normal features (number of channels,techn. refinements etc.).

    The values for electricity consumption stated in the specification are maximum values.In normal mode they are far below the figures stated.

    Power-down circuits also reduce energy consumption.

    Taking back the product

    Currently it is only possible to take back products when this has been regulated by priorcontract agreements.

    Waste disposal

    Basically the systems from Siemens Wireline Access Networks are produced withoutany hazardous or forbidden substances such Cadmium, PCBs, CFCs or such like. Oncethis product has reached the end of its useful life, it can be fraction separated and dis-posed of without hesitation in accordance with the current state of the art.

    List of materials: Casing: Aluminum, steel, ABS plastic (flame-resistant)

    Surface coating only when this is required by the customer. Modules: Normal electronic components (disposal as

    electronic waste). The board material contains brominated

    flame retardants. The following are to be disposed ofseparately: Electrolytic capacitors, LCDs and mechanicalcomponents (heat sinks)

    Cable Copper Connectors: Gold, plastic

    Special features of specific components are listed in the enclosed dismantling guide.

    All information is provided on a voluntary basis and far exceeds that required by law.Should you have anyother questionsabout our quality and environmental management,please send an e-mail to the following address:[email protected]

    Siemens AG, 2002

    ICN Wireline Access Networks

    Munich/Greifswald

  • 8/12/2019 UMN CMXC c800_1_7619

    17/152

    A50010-A3-C800-1-7619 17

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    2 System Overview

    2.1 ApplicationThe CMXC crossconnect multiplexer is a compact solution to establish small networknodes at 8-kbit/s, 64-kbit/s and 2-Mbit/s level. It supports up to 48 2-Mbit/s ports andmakes it possible to switch 64-kbit/s channels between these ports without blocking.

    The CMXC connects communication paths between the following signals: Max. 240 each with 8 kbit/s in the structure n 8 kbit/s (n = 1, 2 and 4) Max. 1488 each with 64 kbit/s in the structure n 64 kbit/s (n = 1 to 31)

    64-kbit/s channels can be cross connected with and without signaling identification(CAS).

    Max. 48 each with 2 Mbit/sThe 2-Mbit/s signals are available at 32 E1 por ts and 4 PCI interfaces

    (each with 42-Mbit/s signals).Unframed 2-Mbit/s signals are switched through transparently.A frame selected from framed 2-Mbit/s signals can also be used as a referenceframe for signal processing in the CMXC.

    The connections are usually bidirectional, but 2-Mbit/s and 64-kbit/s connections canalso be created unidirectionally or as a loop (loopback).

    Fig. 2.1 CMXC Application (Example)

    The crossconnect multiplexer offers the following possibilities: Switching a maximum of 48 framed (with and without CRC4) and unframed 2-Mbit/s

    signals with up to 1488 switchable 64-kbit/s time slots Group switching of n 64-kbit/s time slots by complying with the frame integrity Bidirectional switching of up to 30 time slots (64 kbit/s) via a subrate matrix to switch

    n 8-kbit/s channels (n = 1, 2 and 4) by changing the signal delays without process-ing the identification

    Establishing scheduled jobs and path protection on 2-Mbit/s level

    LE2 3P7

    P8

    SMX1/4c STM-1/STM-4

    CMXC

    ZS1

    ZS60

    FMX2R3.1

    LE2 1

    .

    .

    .

    .

    .

    .

    .

    .

    .

    .

    .

    .

    P1 P17

    P3

    P32

    P2

    P4

    P1

    P16

    P9

    P16

    .

    .

    .

    .

    .

    .

    E1, 2 Mbit/sG.703

    E1, 2 Mbit/sG.703

  • 8/12/2019 UMN CMXC c800_1_7619

    18/152

    18 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    Switching for Sa bits 4 to 8 to be used as the clock control bit in ring structures Providing 4 ECC channels (two synchronous with 64 kbit/s and two asynchronous

    with 9.6 kbit/s) for remote control in TMN (telecommunications Management Net-works) systems

    Creating conference calls for speech signals (30 subscribers in 10 conferences) withdigital conference of the identification

    Digital conferences for 64-kbit/s time slots with data signals (max. 10 conferenceswith up to 30 subscribers) with digital conference of the identification

    Synchronization to one of 7 freely configurable clock sources (2-Mbit/s data lineclocks) or central clock pulse T3

    Supervision of the connection quality according to G.821/G.826 Providing the alarm signaling contacts ZA(A), ZA(B) Software upgrade via the QD2 interface Restore and backup configuration data Complying with the requirements ITU-T G.812 and G.796.

    Fig. 2.2 CMXC Application in an FMX2R3.1 Ring Connection

    For an FMX2R3.1 application it is advantageous if system module FMX2R3.1 is operat-ed together with the CMXC in a ring structure. This includes: Optimum capacity utilization of the 2-Mbit/s lines in an FMX2R3.1 ring 2-Mbit/s path protection is retained in a ring structure Both 2-Mbit/s ports of the CUD unit are available in a ring structure for the transmis-

    sion of basic channels Possibility of optionally cross connecting 8-kbit/s and 64-kbit/s channels Suitable structures for network management

    Concentration in the CMXC such as four ECC interfaces to integrate the SNUS shelfand other system components in TMN.

    CMXC

    CMXC

    CMXC

    CMXC

    FMX2R3.1FMX2R3.1

    FMX2R3.1

    FMX2R3.1

  • 8/12/2019 UMN CMXC c800_1_7619

    19/152

    A50010-A3-C800-1-7619 19

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    2.2 Structure

    2.2.1 Overview

    The following units belong to Crossconnect Multiplexer CMXC: One or two central CUCs (central unit cross connect)

    The central unit contains the switching matrix via which the communication pathsare connected. A second central unit is connected in parallel for module redundancy.

    Up to two interface PU16 units (port unit with 16 2-Mbit/s ports)The interface unit provides the 2-Mbit/s interfaces. One or two PU16s are equippeddepending on the number of desired interfaces.

    Fig. 2.3 CMXC Block Diagram

    2.2.2 External Interfaces

    2-Mbit/s Interfaces (E1)

    16 2-Mbit/s interfaces (E1in, E1out) are established for each PU16 unit.HDB3-coded PCM signals are received and sent at the E1 interfaces. They correspondto the ITU-T recommendation G.703/6.The line impedance 75 unsymmetrical or 120 symmetrical can be set individuallyfor each interface by means of jumpers (see Section 3.3.3).

    PCIS5 to 8

    CUC

    PU16

    CUCS

    PCI5 to 8PCI1 to 4

    PCIS1 to 4

    CCURCCURS

    LSI (1 to 7)SVB

    ST

    SBCC

    QD2-ST3in T3out

    PCI9 to 12

    PCIS9 to 12

    ZA(A), ZA(B)

    48 V

    4ECC (V.11)

    ZA(A), ZA(B)48 V

    4ECC (V.11)

    2 Mbit/s, G.703 2 Mbit/s, G.703

    1

    16

    17

    32

    .

    .

    .

    .

    .

    .

    PU16

    48 V48 V

    redundant CUC

    CCUR

    CCURS

  • 8/12/2019 UMN CMXC c800_1_7619

    20/152

    20 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    PCI Interfaces

    There are four PCI links on the central CUC for external connections to other systemmodules of FastLink (for later applications) via lines not exceeding 15 m. The PCI inter-

    faces are proprietary, symmetrical interfaces with levels according to EIA RS422 andterminating resistors 100 serial in the transmit direction and 150 parallel in the re-ceive direction. The frame structure and time slot allocation of PCI links are containedin Section 2.2.2.

    T3 Interface

    For clock synchronization, a clock signal can be fed via interface T3in and sent viaT3out. The interface is on the CUC and corresponds to the ITU-T recommendationG.703/10. The input impedance of T3in can either be connected with high-impedance(1.6 kII < 120 pF) or with low-impedance (120 symmetrical/75unsymmetrical).

    A clock signal is sent at T3out if the cross connect is synchronized by T3in or E1in of an

    2-Mbit/s port. The interface is designed with low-impedance and is disconnected whenswitching over to the redundant CUC.

    QD2 Slave Interface

    The CUC has a QD2 slave interface according to EIA RS485 which forms the TMN ac-cess to the network element CMXC. Because the number of subscribers is not fixedfrom the start due to the bus structure and the possibility of different equipping, the in-terface is closed with high-impedance on the unit. Depending on the QD2 structure, thebus termination must be suitably fitted on the outside. Care must be taken that two busloads are active for redundant equipping of CUC (maximum possible number is 32).One QD2 address applies to active and standby CUCs.

    ECC Interfaces

    The ECC interfaces transmit control information from higher-level and to remote systemcomponents. The control information is integrated in an ECC channel (64-kbit/s timeslot) within a 2-Mbit/s signal. The central CUC provides four ECC interfaces. They con-form to ITU-T V.11 and can be accessed via the connector panel.

    Two ECC interfaces are provided as synchronous interfaces (with clock lines) and twoas asynchronous interfaces (without clock lines). The synchronous interfaces are oper-ated with 64 kbit/s. Signal distortions of +5% to 10% are obtained for asynchronous op-eration with 9.6 kbit/s (or lower bit rates).

    Alarm Contacts

    The alarm contacts are arranged on central units CUC and are used to signal alarmmodes of the CMXC system module. They are established as floating relay contacts.Fig. 2.4 shows the allocation of alarm contacts for ZA(A). The alarm contacts ZA(B) aredesigned in an equivalent manner.

    Fig. 2.4 Allocation of Alarm Contacts, Example ZA(A)

    ZA(A)_AZA(A)_R

    ZA(A)_U(PUP)

    ZA(A)

    To theconnector panel

  • 8/12/2019 UMN CMXC c800_1_7619

    21/152

    A50010-A3-C800-1-7619 21

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    Alarm contact ZA(A) optionally signals prompt alarms (A alarm) or service alarms(S alarms) and the selection is menu-controlled. Alarm contact ZA(B) signals deferredalarms (B alarm). The software of both CUCs activates these alarms.

    The criteria to release A, B and S alarms are given in the alarm table (see Section 3.3.2).

    CCUR Interface

    The symmetrical interface lines CCUR (according to RS485), signal redundancy opera-tion. Each CUC signals its active or standby mode via a separate line of the externalequipment so that these can switch over their PCI bus drivers.

    2.2.3 Internal Interfaces

    PCI Interfaces

    The PCI interfaces transmit useful data between the CUC and units PU16. They also

    distribute the clocks of the master clock from the CUC to the peripheral equipment.A PCI link establishes a point-to-point connection between the CUC and the two PU16svia two symmetrical two-wire lines (separately in the upstream and downstream direc-tion) on the rear panel. The external PCI interfaces (section 2.2.2) are established viawire pairs within a cable screen and can span distances of up to 15 m. Data signals withsymmetrical levels from which the frame and clock information is retrieved are transmit-ted via each wire pair.

    The PCI frame contains 162 time slots with a width of 10 bits each. The CAS bit is notused in the CMXC and is loaded on fixed potential.

    The PCI time slots are designed according to Tab. 2.1.

    A useful load of 4 2-Mbit/s links with 32 PCM time slots each is mapped into each PCIframe as shown below:

    Bit 1 2 3 4 5 6 7 8 9 10

    TS 0 to 160 D1 D2 D3 D4 D5 D6 D7 D8 CAS P

    TS 161 R 1 1 1 0 0 1 1 0 P

    D1...D8 : PCM data

    CAS : Bit for CAS signaling (not used here)

    P : Parity bit

    R : Reserved bit (in PCI downstream direction: Activity mode of the CUC is displayed)

    Tab. 2.1 Structure of a PCI Time Slot

    PCI

    time slot

    PCM

    link

    PCM

    time slot

    0 1

    01 2

    2 3

    3 4

    Tab. 2.2 PCI Frame Structure

  • 8/12/2019 UMN CMXC c800_1_7619

    22/152

    22 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    LSI Interface

    The LSI interface is established on PU16 (transmitter) and CUC (receiver). It consists of7 symmetrical line pairs and transfers the E1in guide clock from the PU16 to the CUCs.An 8th line pair transfers the frame pulse belonging to the E1 guide clock.Of the two PU16s, only one clock source may be activated per LSI line and the remain-ing transmit drivers are connected with high-impedance. The LSI interfaces are activat-ed via the software according to a clock priority list, see section 2.2.4.

    Supervision Bus SVB

    Internal communication between units CUC and PU16 takes place via the supervisionbus SVB. This bus is an HDLC interface which works according to the master-slave prin-ciple. The master (primary station) is the active CUC and the slaves (secondary station)the PU16 units.The standby CUC does not access the bus and the line drivers are con-nected inactively.

    Supervision bus SVB is used for the following functions: Loading the software and configuration data of units PU16 during intitialization, Distributing the SISA messages via the active CUC to the SISA functional units of

    units PU16, Module-internal communication between CUC and PU16

    (e.g. control commands of the CUC to unit PU16 for clock source control).

    CCUR Interface

    There are two unsymmetrical connections between the units to signal the operatingmode of both CUCs and the PCI buses and their redundancy switchover. On PU16, onlyreceivers are connected to the record circuits whereas they are crossed between theCUC receive and transmit lines. A high level on line CCUR indicates that the left CUCis active and is connected via the primary PCI bus. In this mode, the CCURS line is atthe low level. When changing levels, a switchover to the redundant PCI bus and to theredundant central CUC takes place.

    4 1

    15 26 3

    7 4

    ....

    124 1

    31125 2

    126 3

    127 4

    128

    free...

    160

    161 FSW

    PCI

    time slot

    PCM

    link

    PCM

    time slot

    Tab. 2.2 PCI Frame Structure

  • 8/12/2019 UMN CMXC c800_1_7619

    23/152

    A50010-A3-C800-1-7619 23

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    CC Interface

    The CC interface (cross coupling interface with CC_I and CC_O) connects both CUCsand synchronizes the standby CUC via the clock master. The clock contains the fre-

    quency reference and the position of the central multiframe synchronization pulse is im-pressed via a pulse duration modulation.

    CCR Interface

    The CCR interface connects both CUCs and synchronizes the PCI frame of the standbyCUC via the active CUC.

    STSB Interface

    Data is transmitted between the active CUC and the standby CUC via the STSB inter-face (status standby control). In this way the two CUCs run quasisynchronously andswitch over procedures can be released very quickly via the static command line(CCUR). The STSB interface is a point-to-point connection between the two centralunits inserted next to one another.

    2.2.4 Clock Synchronization

    For the CMXC function it is necessary that all the 2-Mbit/s signal streams E1in andE1out are applied with the same clock signal. This requirement is met if the signals atthe output of preceding equipment is derived from the same synchronous clock; other-wise is must be guaranteed by establishing clock loops in all the closed user terminals(transmitting clock = recovered receive clock). On violation of this principle, frame slipsoccur which lead to interferences in signal transmission.

    The active CUC is the clock master for all the other CMXC units.

    The 2-MHz guide clock can be derived from the following clock sources, see Fig. 2.5: T3in interface to feed an external synchronous clock, Regenerated clock signal which was retrieved from the E1in data of a 2-Mbit/s port Internal oscillator on the CUC (emergency operation).

    7 symmetrical wire pairs LSI1 to LSI7 (line synchronization input) have been providedfor the E1in guide clocks from the PU16 units to the CUC. The source for the guide clockcan be selected at random from the 32 E1 ports. The software selects the activatedclock source on the basis of a priority list. This decides which one of the possible receiveclocks of the E1in ports are loaded on which of the 7 guide clock lines.

    If PU16, which provides a guide clock, identifies a malfunctioning of the E1in signal, it

    disconnects the corresponding clock source. The CUC then identifies clock failure andswitches over to the clock source with the next lower priority (see the alarm table of theCUC in Section 3.3.2). If all the external clock sources fail, the PLL of CUC is switchedto free-running and a prompt alarm is released.

    If a clock source with a higher priority becomes available while operating with a lowerpriority standby clock, the guide clock switches over automatically.

  • 8/12/2019 UMN CMXC c800_1_7619

    24/152

    24 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    Fig. 2.5 CMXC Synchronization

    Phase synchronicity requirements of G.703 interface signals can be found in the ITU-T-recommendations G.823 and ETS TBR-12 and they are formed by buffer stores and jit-ter reducers on units PU16. An elastic store sets up the frame synchronicity.

    The synchronous clock on units PU16 is derived by means of PLL from the PCI down-stream signal.

    For subsequent equipment, the active CUC provides a 2.048-MHz synchronous clockT3out which is synchronous to the current system clock.

    Both CUCs manage the T3 interface. The software ensures that only the active CUC ac-cesses the interface.

    2.2.5 Conferences

    A maximum of 30 digital and 30 analog conference channels can be switched in up to20 mutually independent conferences at the same time. The requirements for analogand digital conferences differ:

    For the analog conference, each conference participant receives the total of all the othersignals. Its individual transmit signal is deactivated. The identifications are switched dig-itally for the participants in analog conferences.

    For the digital conference, the signals of all the participants are switched with bit-by-bitOR operation. Its individual transmit signal is retained. For the participants in digital con-

    ferences, the identifications are also switched digitally as for analog conferences.

    ....

    ...

    LSI1 LSI7...

    E1in/17 to 32...

    T3in T3out

    E1in/1 to 16 ...

    PCIup CUC standbyCUC

    PU16PU16

    Analog conferences Digital conferences

    Maximum number of conference participants 30 30Maximum number of participants per conference 10 30

    Maximum number of parallel conferences 10 10

    Tab. 2.3 Conference Requirements

  • 8/12/2019 UMN CMXC c800_1_7619

    25/152

    A50010-A3-C800-1-7619 25

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    2.2.6 Subrate Multiplexer

    To switch subrate connections, a subrate channel of 1, 2 or 4 bits is converted to 8 fullbits and then switched and compressed again. Conversion takes place by oversampling

    or subsampling.A maximum of 240 bidirectional subbit rate signals each with 8 kbit/s in CMXC can beswitched.

    2.2.7 Voice Channel in Common Frequency Radio Networks

    In this application a voice channel is transmitted from one source to a number of desti-nations. The group delay time of the voice channel is constant here. There can only beone such connection within the network. This connection is always unidirectional.

    The source can only be a VF interface in multiplexer FMX2R3 (with units CUD andUAC68). All subsequent multiplexers/crossconnect multiplexers must synchronize

    themselves to the outgoing frames of the multiplexer with the synchronizing clocksource.

    2.2.8 Redundancy Concept

    2.2.8.1 Module Redundancy

    To increase the operating reliability of CMXC, the central CUC is duplicated so that fur-ther functioning of the entire system is guaranteed if the unit fails. Failure of the activeCUC leads to a redundancy switchover if there is another CUC in the CMXC systemmodule. The software releases redundancy switchover. To this end, the operability of all

    the components is supervised on both CUCs (active and standby).Units PU16 are not equipped redundantly, i.e. there is no protection switching if a PU16unit fails. Therefore, the CMXC system module has a fault penetration range of 16 E1interfaces.

    Fig. 2.6 Redundancy Concept

    The PCI buses are duplicated, see Fig. 2.6. A switchover to the redundant bus is pos-sible in case of faults. The central CUCs are connected to separate signal groups (PCISat standby unit).

    PCI1 to 8

    PCIS1 to 8

    STSBCCUR

    CCURS

    CCUR

    CCURS

    PU16

    CUC

    CUCSPU16

    CCUR

    To external equipment

    Redundant CUC

  • 8/12/2019 UMN CMXC c800_1_7619

    26/152

    26 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    However, the decentralized PU16 units are connected to both the bus systems. Theyreceive information about which one of the two PCI buses is active, the CCUR andCCURS signals (see CCUR Interface).

    Bus STSB is used as the communication interface for redundancy operation betweenthe two CUCs (see STSB Interface).

    The clock sources for the synchronous clock of CMXC is switched over to standby ac-cording to a priority list (see section 2.2.4).

    Both CUCs manage the T3 interface and the QD2 interface. The software ensures thatonly the active CUC accesses the specific interface.

    2.2.8.2 Alternative Route Switching for a 2-Mbit/s Connection

    One alternative route can be configured for each 2-Mbit/s connection which is switchedover to for the alarm criteria below:

    LOS, AIS,Local loop, remote loop always

    SYN, BER-3, only for framed signals SYNK, AISK, only for framed signals with CAS signaling BER-5/-6 only for framed signals, if the alarm criterion

    was switched on D-Bit, Dk-Bit, N-Bit, Nk-Bit never

    The alternative route must be entered into the user menu.

    The alarm criterion BER-5/-6 has a lower priority than the LOS, AIS, SYN, BER-3, AISK,SYNK, local loop and remote loop alarms. If a high priority alarm occurs at the one portand a low priory alarm at the other port, the low priority alarm will be used as the trans-

    mission route. Therefore, the alarm criterion should be switched on.

    2.2.9 Power Supply

    Units CUC and PU16 of CMXC are supplied with an input voltage of 48 V (36 V to72 V). The input voltage is fed via a plug in the connector panel of the shelf. For redun-dancy operation, a second plug (S) is provided to feed a further 48 V. The active andstandby CUCs are connected to either of the two voltages in each case. The PU16 unitsare connected to both voltages. The input voltages are fed to the consumers via EMCfilters on the backplane of the shelf.

    Fig. 2.7 Power Supply in Shelf SNUS

    CUCSCUC

    PU16 PU16

    Connector panel

    48 V/60 V 48 V-S/60 V-S

  • 8/12/2019 UMN CMXC c800_1_7619

    27/152

    A50010-A3-C800-1-7619 27

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    2.3 Operation and Supervision

    2.3.1 Access to CMXC

    The CMXC forms an SISA Network Element. The central CUC accesses the NetworkElement via the QD2 slave interface. Addressing the CMXC Network Element is allocat-ed slot-coded via the rear panel of shelf SNUS.

    The following types of access are possible, see Fig. 2.8: CMXC connection to the OS via the QD2 slave interface

    QD2 access is in stand-alone operation of unit SNUS via the supervision unit SUE.Switch positions connect the internal QD2 bus to the master port of the SUE.

    LCT connection via the F interface of the supervision unit.

    In stand-alone operation, the DCN channels are connected directly to the QD2 slaveport of SUE via the connector panel of the shelf.

    Fig. 2.8 CMXC in Stand-alone Operation Mode (Example)

    2.3.2 Operating Elements

    The CUC has a jumper to set the impedance of the T3in interface to high-impedance(1.6 k II < 120 pF) or low-impedance (120 symm./75 unsymm.) operation (seeSection 3.3.3).

    Jumpers are located on units PU16 to set the impedances of the E1 interfaces. The lineimpedance of each F1 interface can either be set separately to 75 unsymmetrical orto 120symmetrical (see Section 3.4.3).

    A 5-step DIL switch is arranged on shelf SNUS to set the SISA address of the systemmodule (see Section 3.2.4).

    Detailed information about the switch settings and plug connector allocations can befound in Section 3.

    2.3.3 SupervisionSMD-LEDs signal the operating mode for each unit (see Section 3.3.2to 3.4.2).

    NEASA32

    LCTF

    SISA-VLMX/V2

    SUE

    QD2 slave 1RS485/RS232

    V.28

    QD2 slave 2

    Internal QD2 bus

    RS485primary

    CMXC

    SISA-V

    ECC (V.11)FMX2R3

    SISA-V

    SMX1/4c

    SISA-V

    LTCOH/LT

    SISA-V

    LT12CM/LTLT22CM/LTLTO/LT

    Internal QD2 bus

    T port (QD2 slave 1) for other NEs

    QD2-M

  • 8/12/2019 UMN CMXC c800_1_7619

    28/152

    28 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    The E1, PCI and LSI interfaces are supervised according to alarm tables on the units(see Section 3.3.2to 3.4.2). the CUC supervises PCI and LSI links between the PU16 and the CUC. PU16 evaluates the E1 interfaces.

    SISA0 alarms are reported to the OA&M computer. Two LEDs (red and green) on theCUC indicate the system alarms.

    2.3.4 Diagnostic Functions

    When switching on the input voltages for CMXC, self-test routines of the software andhardware components on the units are first of all performed.

    In operation, PCM signals received at the E1 ports can be analyzed continuously ac-cording to ITU-T G.821 and the values stored in quality data records. Both the currentquality counter and any stored record can be displayed.

    The number of frame slips occurring at a 2-Mbit/s port can be requested via the craftterminal.

    The following loop connections can be established on PU16, see Section 3.4.1: Local loop for fault location within the CMXC system module, Remote loop for fault location of the external 2-Mbit/s connections.

    The procedures for alarm evaluation are contained in the Section 5.

    2.4 Software

    The required SW of network element CMXC is loaded with the craft terminal and SWdownload via the V.24 or the QD2 interface. Special SW in the form of a file exists for

    each CMXC unit.

    2.4.1 Storage Structure

    Each one of the units has a unit computer consisting of a micro controller and variousstorage circuits (FEPROM, EEPROM, RAM) for administering the software and the da-ta. The micro controller controls the internal functional flow on the individual units. Thestorage circuits are used for software and data protection.

    In order to retain the configuration in case of a fault, backup versions are stored in theOS which can then be set up again at a later stage.

    Firmware containing the initial program loader, self-test programs and type label data

    are found on each unit. The firmware is stored in the flash EEPROM on the unit.

    The RAM contains the current SW which is loaded from the FEPROM by the initial pro-gram loader.

    2.4.2 Initializing

    After power-up each unit starts the initial program loader software contained in theFEPROM. The initial program loader comprises the self-test routines of the unit (dura-tion a maximum of 30 s) and log-in into the supervision bus. After successful softwaredownload and starting, the units read-in their configuration data.

    For an SW update, the current SW version carries on working in the RAM. A reset mustalways be performed after a new SW has been loaded, so that the unit can reboot.

  • 8/12/2019 UMN CMXC c800_1_7619

    29/152

    A50010-A3-C800-1-7619 29

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    3 Components

    3.1 GeneralThe CMXC consists of a maximum of two CUC units and a maximum of two PU16 unitsin double eurocard size. The units are installed in an SNUS shelf.

    The SUE unit used for stand alone operation mode is equipped in SNUS shelf also.

    The 19-inch SNUS shelf is used for indoor operation. It can be delivered as stand-aloneor with a complete infrastructure (with power supply, backup battery and signal distrib-utor) as SNU60FTTB or in an SNU180FTTB.

    The following system modules can be equipped in SNUS together with CMXC: Multiplexer FMX2R3.1 Line equipment for 2-Mbit/s transmission

    on copper cablewith UK2interface according to FTZ 1 TR221 or G.703/short-haul (LT2ME1),HDSL-coded (12 Mbit/s with LTCOH/LT12CM or 2 2 Mbit/s with LT22CM),

    on optical cable via single mode glass fibers12 Mbit/s via 2 fibers according to FTZ 1 TR222 (LUOT-A), or22 Mbit/s, transmit and receive direction via 1 fiber (LTO).

    Synchronous multiplexer SMX1/4c or the optical line equipment OMX16

    All external CMXC interfaces can be accessed via the connector panel of the shelf.Should FMX2R3.1, 2-Mbit/s line equipment and OMX16/SMX1/4c be equipped, the2-Mbit/s interfaces have already been prewired internally and only a section of the inter-faces can be accessed from the outside. Detailed information about internal wiring can

    be found in the User Manual FMX2R3.1, UMN, see Section 1.3 "Additional Documenta-tion".

  • 8/12/2019 UMN CMXC c800_1_7619

    30/152

    30 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    3.2 SNUS Shelf

    3.2.1 SNUS Layout

    Fig. 3.1 SNUS with Front Panel

    101X1V1A1 B1 C1 D1 E1 F1 G1 H1 J1 K1 L1 M1 N1 P1 Q1 R1 S1

    E2 F2 G2 H2 J2 K2 L2 M2 N2 P2 Q2 R2 S2 T2D2C2B2

    Y2X2U2 W2V2

    U3 V3 W3 X3Y3

    SMX DSMXTrib.Unit

    T3

    T3

    (+)(-)48V

    6A

    (+)(-)48V

    6A

    QD2-Slave

    QD2-Master

    Tln

    Tln

    Tln

    G.703

    Tln

    Tln

    Tln

    G.703 H

    DSL(LT3)

    PCI

    G.703

    G.703

    G.703

    G.703

    G.703

    1..4

    9..12

    1..4

    9..12

    17..21

    1..4

    9..12

    address116

    onoff

    LC1

    FRCON

    LC2

    LC3

    LC4

    LC5

    LC6

    LT2

    PBA2

    Port Unit 1 CMXC Port Unit 2 Trib Unit SMX

    A3

    Tln

    Tln

    Tln

    Tln

    Tln

    Tln

    G.703

    G.703

    5..8

    13..16

    ECC

    PCIS

    G.703

    G.703

    5..8

    13..16

    G.703

    G.703

    5..8

    13..16

    G.703

    17..21

    V.11

    xt.contacts

    ZA

    LT1

    12

    12

    12

    12

    12

    12

    12

    12

    12

    12

    F-PC

    SIEMENS SNUS

    LASER KLASSE 1

    LASER CLASS 1

    Achtung!

    Laser und Glasfasermechanischnicht belasten

    ATTENTION!LASER AND GLASS FIBER

    MUST NOT BEPHYSICALLY DAMAGED

    OR STRAINED

    BA DC FE HG KJ ML PN RQ TS VU XW

  • 8/12/2019 UMN CMXC c800_1_7619

    31/152

    A50010-A3-C800-1-7619 31

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    Fig. 3.2 SNUS Front View with the DIL Switches S101 to S116

    Fig. 3.3 DIL Switches S105 to S116

    BA DC FE HG KJ ML PN RQ TS VU XW YX1V1A1 B1 C1 D1 E1 F1 G1 H1 J1 K1 L1 M1 N1 P1 Q1 R1 S1

    address116

    onoff

    QD

    2-Slave

    QD

    2-Master

    T

    ln

    T

    ln

    T

    ln

    G.703

    T

    ln

    T

    ln

    T

    ln

    G.703 H

    DS

    L(LT3)

    PCI

    G.703

    G.703

    G.703

    G.703

    G.703 (+

    )(-)48V

    6A

    (+

    )(-)48V

    6A

    Y2X2U2

    E2 F2 G2 H2 J2 K2 L2 M2 N2 P2 Q2 R2 S2 T2LC1

    FRCON

    LC2

    LC3

    LC4

    LC5

    LC6

    LT2

    LT1

    1..4

    9..12

    1..4

    9..12

    17..21

    1..4

    9..12

    W2V2

    D2C2B2

    PBA2

    Port Unit 1 CMXC Port Unit 2 Trib Unit SMX

    A3

    Tln

    Tln

    Tln

    Tln

    Tln

    Tln

    G.703

    G.703

    5..8

    13..16

    ECC

    PCIS

    G.703

    G.703

    5..8

    13..16

    G.703

    G.703

    5..8

    13..16

    G.703

    17..21

    V.11

    U3 V3 W3 X3Y3

    SMX DSMXTrib.Unit

    T3

    T3

    xt.contacts

    ZA

    201 202 204 205 206 207 208 209 210 211 212 213 214 215 216 217 SNUS

    201202

    204 205 206 207 208 209 210 211 212 213214

    215216

    217

    101

    S10 3 S1 04

    S102

    S111 S112 S114 S115

    S113 S116

    S108

    S109

    S105

    S106

    S107

    S101

    As-delivered condition:For S105to S116all sliders are set tothe downposition.These DIL switches are not used for System

    Module CMXC.

    ON

    S1141 2 3 4

    ONS108

    ONS109

    ON

    S1111 2 3 4

    ON

    S1121 2 3 4

    ONS105

    ON

    S1131 2 3 4

    ONS106

    ONS107

    ON

    S1151 2 3 4

    ON

    S1161 2 3 4

  • 8/12/2019 UMN CMXC c800_1_7619

    32/152

    32 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    3.2.2 Addressing

    Almost all units in the SNUS are assigned addresses via the backplanes. The addressesassigned to the slots are shown in Tab. 3.1.

    The SISA addresses of the SUE are set using DIL switch 101 in the terminal panel (pos-sible addresses: 1 to 30), see Fig. 3.6and Fig. 3.4.

    Fig. 3.4 DIL Switch S101

    The addresses implemented in the SNUS are shown in Tab. 3.1.

    Unit In slot QD2 address Slot address (connected and fixed)

    SUE 201 Is set using DIL switch

    S101 in the terminal panel

    of the SNUS, see Fig. 3.6

    and Fig. 3.4.

    5Bit = 1 to 30

    5 bit = 3

    (K0...K4 shelf model)

    CUD 202 Is set using DIL switch

    S102 on the backplane of

    the SNUS, see Fig. 3.2.

    5Bit; here only 1 to8 usable

    SEL_0 = GND

    SEL_1 = GND

    Line cards 1-6 203 to 208 4 bit = 1 to 6

    LT1 as LU1) 3) 207 Fixed (4 bit) = 7

    LT1 as LT2) 3) 207 Fixed (5 bit) = 7

    LT2 as LU1) 3) 208 Fixed (4 bit) = 8

    LT2 as LT2) 3) 208 Fixed (5 bit) = 8

    LT3 as LU1) 209 Fixed (4 bit) = 9

    LT3 as LT2) 209 Fixed (5 bit) = 9

    PU16(1) 210 5 bit = 10

    CUC(1) 211 Fixed (5 bit) = 13 5 bit = 11

    CUC(2) 212 Fixed (5 bit) = 13 5 bit = 12PU16(2) 213 5 bit = 13

    ADM (SMX) 216 Fixed (5 bit) = 16

    Trib.Unit 214

    LU1)= LUOT, LUCP, LUC, LUCT

    LT2)= LTO, LTCOH, LT12CM, LT22CM, LT2ME1

    3) If an LT/LU unit instead of a line card is equipped in slots 207 or 208, the slot must be configured accord-

    ingly (with DIL switches S106 and S107 for slot 207 or with DIL switch S109 for slot 208). Switches S105

    and S108 must always be switched, see Fig. 3.2, Fig. 3.3

    Tab. 3.1 SNUS Overview of Addressing and the Units

    1

    ON = LOW = log 0Example:Switch 1 on OFF corresponds to 24= 16Switch 5 on OFF corresponds to 20= 1Corresponds to address 17 for the SUE

    ON (0)

    OFF (1)

    24 23 22 21 20

    5

  • 8/12/2019 UMN CMXC c800_1_7619

    33/152

    A50010-A3-C800-1-7619 33

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    3.2.3 QD2 Structure

    If the stand alone operation mode the SUE must be used for supervision. Operating ormaintenance functions can be carried out locally via an F interface using a local craftterminal. The SUE monitors all units in the SNUS. The internal QD2 bus of the SNUSmust be switched using switches S103 (all slider units on OFF) and S104 (all sliderunits on ON) to the SUE master port, see Fig. 3.2and Fig. 3.5.

    Slave port 1 of the SUE is executed as a T interface, likewise the T connections are ac-cessible in the X101 slave connector, see Fig. 3.6.

    Master port 1 of the SUE is stored in the QD2 X102 master connector and is the startingpoint of the internal QD2 bus when used in standalone mode. Further slaves in the in-ternal QD2 bus can be connected to X102.

    Slave port 2 of the SUE is also located in the QD2 X102 master connector. The over-head interface of LT location 3 is also located here. Connection to slave 2 via an appro-priately assigned connector is possible and thus a control channel via the overhead froma remote device (unit in LT location 3 as a feeder for the SNUS).

    Further control is possible via ECC channels. The ECC connections of both CUC loca-tions are stored in parallel and in a 25-pin D-sub connector. Of the four ECC interfacesof the CMXC, two are equipped with clock transmission. The ECC of the CUD is also

    routed to this X131 D-sub.

    Fig. 3.5 DIL Switches S103 and S104

    PSD 218 5 bit = 18

    optional with

    OMX16

    DSMX34 215 5 bit = 15

    OTRU36 217 5 bit = 17

    OTSU_2M 218 Fixed (5 bit) = 18

    Unit In slot QD2 address Slot address (connected and fixed)

    LU1)= LUOT, LUCP, LUC, LUCT

    LT2)= LTO, LTCOH, LT12CM, LT22CM, LT2ME1

    3) If an LT/LU unit instead of a line card is equipped in slots 207 or 208, the slot must be configured accord-

    ingly (with DIL switches S106 and S107 for slot 207 or with DIL switch S109 for slot 208). Switches S105

    and S108 must always be switched, see Fig. 3.2, Fig. 3.3

    Tab. 3.1 SNUS Overview of Addressing and the Units (Cont.)

    ON

    S104

    4321

    ON

    S103

    4321

    As-delivered condition:For S103 all slider units are set to OFF (down position) and forS104 all slider units are set to ON (up position), i.e. the SNUS ismonitored by a SUE(standalone, without COMPS and without OSU)

  • 8/12/2019 UMN CMXC c800_1_7619

    34/152

    34 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    3.2.4 Position and Assignment of Connectors

    Fig. 3.6 Location of Connectors and Equipping of Units

    In the following topics, assignments of connectors in Terminal Panel used for the CMXCunits are only described.

    48V

    48V

    QD2-S

    Alarm

    PB

    -+

    -+

    A

    X101 to X154 are the connectors in the terminal panel

    X201 to X316 are the connectors for the units in the shelf

    1) DIL switch S101 for setting the SISA address of the SUE

    2) LT1/2/3 = LT/LU units (LT22CM may only be inserted into slot 209)

    C

    QD2-M

    B D E F G H

    I/O1-4

    J

    I/O9-12

    K

    HDSL-LT3

    L

    PCI

    M

    I/O1-4

    N

    I/O9-12

    P

    I/O1-4

    Q

    I/O9-12

    R

    I/O1

    7-21

    S

    I/O5-8

    I/O1

    3-16

    ECC-CUC

    PCIS

    I/O5-8

    I/O1

    3-16

    I/O5-8

    I/O1

    3-16

    I/O1

    7-21

    ZA

    T3an

    T

    3out

    V.11

    Add.1)

    E3IN

    X153

    X151

    E3OUT

    X154

    X152

    X301

    201

    X201

    SUE

    X302

    202

    X202

    CUD

    /CUA

    X303

    203

    X203

    LC1/FRCO

    N

    X304

    204

    X204

    LC2

    X305

    205

    X205

    LC3

    X306

    206

    X206

    LC4

    X307

    207

    X207

    LC5/LT12)

    X308

    208

    X208

    LC6/LT22)

    X309

    209

    X209

    LT32)

    X310

    210

    X210

    PU16

    X311

    211

    X211

    CUC

    X312

    212

    X212

    CUC

    X313

    213

    X213

    PU16

    X14D

    X14C

    214

    X14BX14A

    TU

    X314

    215

    X214

    DSMX34

    X15D

    X15C

    216

    X15BX15A

    ADM

    X316

    218

    X216

    OTSU_

    2M/

    PSD

    X315

    217

    X215

    OTRU36

    or

    or

    X121X122

    X123 X125 X127 X129 X131 X133 X135 X137

    X124 X126 X128 X130 X132 X134 X136

    X138

    Exchangeconn.

    LCslots 2Mbit/s 2Mbit/s2Mbit/s

    X120

    X104 X106 X108 X110 X112 X114 X116

    X103 X105 X107 X109 X111 X113 X115 X117 X141 X142X101

    X102

    X143

    X144

    Slot desig-

    nations

    S101

    T

  • 8/12/2019 UMN CMXC c800_1_7619

    35/152

    A50010-A3-C800-1-7619 35

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    Connectors of the Power Supply (X141 and X142)

    QD2 (X101 and X102) and Alarm Inputs (X121)

    Notes to Tab. 3.3:GND = operation ground

    GND_S = shielded ground

    For X101:

    Slave1 from SUE

    QD2S1 In a/b

    QD2S1 OUT a/b

    T-connections to Slave1 of the SUE

    QD2T IN a/b

    QD2T OUT a/b

    X141 Pin X142 Pin

    1 1

    -48V (MUP1) 2 -48V (MUP2) 2

    +48V (GND) 3 +48V (GND) 3

    Tab. 3.2 Assignment of Connectors X141 (left and ) X142 (right)

    Pin X101

    QD2-Slave

    X102

    QD2-Master

    X121

    Alarm inputs

    1 GND_S GND_S GND_S

    2 QD2S1 OUT a QD2M IN a AIN1

    3 QD2T1 OUT a AIN3

    4 QD2S1 IN a QD2M OUT a AIN5

    5 QD2T1 IN a AIN7

    6

    7 DAT

    8 GND GND GND

    9 QD2S1 OUT b QD2M IN b AIN2

    10 QD2T1 OUT b AIN4

    11 QD2S1 IN b QD2M OUT b AIN6

    12 QD2T1 IN b AIN8

    13

    14 NRST

    15 CLK

    Tab. 3.3 Terminal Assignment of Jacks X101, X102 and X121

  • 8/12/2019 UMN CMXC c800_1_7619

    36/152

    36 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    DAT, CLK, NRST = not used in CMXC

    For X121:AIN1 to AIn8 = alarm inputs of the SUE

    AM = negative operating voltage for alarm contacts

    For X102:Master from SUE:

    QD2M IN a/bQDM OUT a/b

    T3 Interface (X143 and X144)

    Notes to Tab. 3.11:GND = operation ground

    GND_S = shielded ground

    For X143:T3 OUT1 a/b = T3-output from CUC plug-in places

    T3 OUT2 a/b = T3-output from CUD plug-in place (202)

    For X144:T3 IN1 a/b = T3in1-input to CUD-, LT-/LU-, and CUC plug-in places

    T3 OUT1 a/b = T3in1-output to the Terminal Panel

    T3 IN2 a/b = T3in2-input to the ADM plug-in place

    T3 OUT2 a/b = T3in2-output to the Terminal Panel

    Pin X143

    Connector T3ab

    X144

    Connector

    T3an

    1 GND_S GND_S

    2 T3 OUT1 a T3 IN1 a

    3 T3 OUT1 a

    4 T3 OUT2 a T3 IN2 a

    5 T3 OUT2 a

    6 T3 OUT1 b T3 IN1 b

    7 T3 OUT1 b

    8 T3 OUT2 b T3 IN2 b

    9 T3 OUT2 b

    Tab. 3.4 Terminal Assignment of 9-Contact Jacks X143 and X144

  • 8/12/2019 UMN CMXC c800_1_7619

    37/152

    A50010-A3-C800-1-7619 37

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    ZA Contacts (X122) and ECC of the CUC (X131)

    Notes to Tab. 3.11:GND = operation ground

    GND_S = shielded ground

    For X122:

    Index 1 = SUE

    Index 2 = CU plug-in place (202), not used in CMXC

    Index 3...5 = LT plug-in places (207 to 209), not used in CMXC

    Index 6, 7 = CUC, plug-in places 211 and 212

    Index 8 = PSD plug-in place 218, not used in CMXC

    Pin X122

    ZA-contacts

    X131

    ECC of the CUC

    (in addition to CUD)

    1 GND_S GND_S

    2 EAN_A1

    3 ZAA2 EAB_A1

    4 ZAA3 ET_A1

    5 ZAA4 EAN_A2

    6 ZAA5 EAB_A2

    7 ZAA6 ET_A2

    8 ZAA7 EAN_A3

    9 ZAA8 EAB_A3

    10 ZAA9 EAN_A4

    11 EAB_A4

    12 EANCUD_A

    13 GND EABCUD_A

    14 ZAB1 EAN_B1

    15 ZAB2 EAB_B1

    16 ZAB3 ET_B1

    17 ZAB4 EAN_B2

    18 ZAB5 EAB_B219 ZAB6 ET_B2

    20 ZAB7 EAN_B3

    21 ZAB8 EAB_B3

    22 ZAB9 EAN_B4

    23 EAB_B4

    24 EANCUD_B

    25 GND EABCUD_B

    Tab. 3.5 Terminal Assignment of Jacks X122 and X131

  • 8/12/2019 UMN CMXC c800_1_7619

    38/152

    38 A50010-A3-C800-1-7619

    UMN CMXC User ManualCrossconnect Multiplexer CMXC

    Index 9 = OTSU2M, plug-in place 218, not used in CMXC

    (optional equipping)

    For X131:ECC1 to ECC4 of the CUC from both units (connect in parallel)

    ECC1 and ECC2 with clock

    ECC3 and ECC4 without clock

    Interfaces 2 Mbit/s G.703 (X109 to X110, X129 to X130, X113 to X117 and X133 to

    X137)

    Interfaces 2 Mbit/s G.703

    Pin X109/X113 X129/X133 X110/X114 X130/X134

    1 GND_S GND_S GND_S GND_S

    2 E1 OUT1 a E1 OUT5 a E1 OUT9 a E1 OUT13 a

    3 E1 IN1 a E1 IN5 a E1 IN9 a E1 IN13 a

    4 E1 OUT2 a E1 OUT6 a E1 OUT10 a E1 OUT14 a

    5 E1 IN2 a E1 IN6 a E1 IN10 a E1 IN14 a

    6 E1 OUT3 a E1 OUT7 a E1 OUT11 a E1 OUT15 a

    7 E1 IN3 a E1 IN7 a E1 IN11 a E1 IN15 a

    8 E1 OUT4 a E1 OUT8 a E1 OUT12 a E1 OUT16 a

    9 E1 IN4 a E1 IN8 a E1 IN12 a E1 IN16 a

    10

    11

    12

    13

    14 E1 OUT1 b E1 OUT5 b E1 OUT9 b E1 OUT13 b

    15 E1 IN1 b E1 IN5 b E1 IN9 b E1 IN13 b

    16 E1 OUT2 b E1 OUT6 b E1 OUT10 b E1 OUT14 b

    17 E1 IN2 b E1 IN6 b E1 IN10 b E1 IN14 b

    18 E1 OUT3 b E1 OUT7 b E1 OUT11 b E1 OUT15 b

    19 E1 IN3 b E1 IN7 b E1 IN11 b E1 IN15 b

    20 E1 OUT4 b E1 OUT8 b E1 OUT12 b E1 OUT16 b

    21 E1 IN4 b E1 IN8 b E1 IN12 b E1 IN16 b

    22

    23

    24

    25

    Tab. 3.6 Terminal Assignment of Jacks X109, X110, X 113, X114, X129, X130,X133, X134 and X115

  • 8/12/2019 UMN CMXC c800_1_7619

    39/152

    A50010-A3-C800-1-7619 39

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    Notes to Tab. 3.6:GND_S = shielded ground

    For X109, X129, X110 and X130:

    E1 OUTy a = a-wire,E1 OUTy b = b-wire from output 2Mbit/s G.703 from Port y (PU16/1)E1 INy a = a-wire,E1 INy b = b-wire from input 2Mbit/s G.703 from Port y (PU16/1)E1 = 2Mbit/s G.703Example:E1 OUT1 a = a-wire,E1 OUT1 b = b-wire from output 2Mbit/s G.703 from Port 1 (PU16/1)E1 IN1 a = a-wire,E1 IN1 b = b-wire from input 2Mbit/s G.703 from Port 1 (PU16/1)E1 = 2Mbit/s G.703

    The external names E1 IN.. E1 OUT.. are relate to the PU16.

    The internal Interfaces from X109 are port 1 to 4 of the PU16/1 in Slot 210.The Interfaces from X129 are port 5 to 8 of the PU16/1 in Slot 210 and are internal con-nected to the first interface of the CUD place and of the 3 LT plug-in places.The interfaces from X110 come from the ADM and are internal connected with port 9 to12 of the PU16/1 in Slot 210.The interfaces from X130 come from the ADM and are internal connected with port 13to 16 of the PU16/1 in Slot 210.

    For X113, X133, X114 and X134:

    E1 OUTy a = a-wire,E1 OUTy b = b-wire from output 2Mbit/s G.703 from Port y (PU16/2)E1 INy a = a-wire,E1 INy b = b-wire from input 2Mbit/s G.703 from Port y (PU16/2)E1 = 2Mbit/s G.703Example:E1 OUT1 a = a-wire,E1 OUT1 b = b-wire from output 2Mbit/s G.703 from Port 1 (PU16/2)E1 IN1 a = a-wire,E1 IN1 b = b-wire from input 2Mbit/s G.703 from Port 1 (PU16/2)E1 = 2Mbit/s G.703

    The external names E1 IN.. E1 OUT.. are relate to the PU16.

    The interfaces from X113 are Port 1 to 4 of the PU16/2 in Slot 213.The interfaces from X133 are Port 5 to 8 of the PU16/2 in Slot 213 and are internal con-nected to the second interface of the CUD place and of the 3 LT plug-in places.The interfaces from X114 come from the ADM and are internal connected with port 9 to12 of the PU16/2 in Slot 213.The interfaces from X134 come from the ADM and are internal connected with port 13to 16 of the PU16/2 in Slot 213.

  • 8/12/2019 UMN CMXC c800_1_7619

    40/152

  • 8/12/2019 UMN CMXC c800_1_7619

    41/152

    A50010-A3-C800-1-7619 41

    User ManualCrossconnect Multiplexer CMXC

    UMN CMXC

    Fig. 3.7 CUC Block Diagram

    The CUC allows conference calls for analog and digital signals as well as correspondingidentification processing (CAS conference). The total number of subscribers for confer-ence operation is 30. These can be a maximum of 10 analog and/or 10 digital confer-ences with 3 subscribers each and a maximum of 10 analog or 30 digital subscribers foreach conference.

    The CUC performs the following functions: Crossconnecting the 64-kbit/s signals in the switching matrix and administering the

    database needed for this Switching analog, digital and CAS conferences and administering associated data Clock generation by selecting the guide clock

    Exchanging configuration and program information between CUC and PU16 via su-pervision bus SVB Data exchange between the CUC and PU16 units via PCI links Standby control Alarm signaling via ZA(A) and ZA(B) contacts and LEDs Providing the time.

    The CUC has the following interfaces: Data

    8 x PCIs as system-internal interfaces to transmit PCM signals between the CUCand the peripheral units PU16

    4 x PCI interfaces for connecting external equipment

    Clock pulses 7 x LSI interfaces to receive the 2-MHz guide clock from PU16

    LSI1 to LSI7

    Frame clock

    System clock

    SVB

    STSB

    T3in

    CC, CCR (unsym.)

    PUP

    MUP

    SISA-ADR (0 to 4)

    CCUR (unsym.)

    5