TÜV Rheinland Product Safety GmbH Am Grauen Stein D - 51105 Köln Tel.: +49 221 806-1371 Fax: +49 221 806-3909 Mail: [email protected] Web: www.tuv.com Rev. 00 2006-04-01/ approved: Hongyan.yu Produkte Products Prüfbericht - Nr.: Test Report No.: 30980453.003 Seite 1 von 35 Page 1 of 35 Auftraggeber: Client: US Lighting Tech 2665 Temple Avenue, Signal Hill, CA 90755 USA Gegenstand der Prüfung: Test item: Flood Lighiing Luminaires - Cobra Street Light Series, Diamond Wall Pack Series, Endura Garage Light Series, Parket Parking Light Series, Ridgeline High Bay Series, Acorn Post Top Exterior Series. Bezeichnung: Identification: 1) CO-3-xxxW-5K 2) DI-3-xxxW-5K 3) EX-3-xxxW-5K or DX-3-xxxW-5K 4) PA-3-xxxW-5K 5) RI-3-xxxW-5K 6) AC-3-xxxW-5K Where xxx = wattage and 250 W max. Refer to page 3 of the report for actual ratings Serien-Nr.: Serial No.: 1) COxxx-000001 2) DIxxx-000001 3) EXxxx-000001 or DXxxx-000001 4) PAxxx-000001 5) RIxxx-000001 6) ACxxx-000001 Wareneingangs-Nr.: Receipt No.: -- Eingangsdatum: Date of receipt: April 8, 2009 Prüfort: Testing location: 1279 Quarry Lane, Ste. A, Pleasanton, CA 94566 Prüfgrundlage: Test specification: EN 60598-2-5:1998 EN 60598-1:2004 Prüfergebnis: Test Result: Der Prüfgegenstand entspricht oben genannter Prüfgrundlage(n). The test item passed the test specification(s). Prüflaboratorium: Testing Laboratory: TUV Rheinland Product Safety GmbH., Am Grauen Stein, 51105 Köln, Germany geprüft/ tested by: 7/2/09 Jim Cheng kontrolliert/ reviewed by: 7/2/09 Ronald Younan Datum Date Name/Stellung Name/Position Unterschrift Signature Datum Date Name/Stellung Name/Position Unterschrift Signature Sonstiges/ Other Aspects: Factory: US Lighting Tech 2665 Temple Avenue, Signal Hill, CA 90755 USA Abkürzungen: P(ass) = entspricht Prüfgrundlage F(ail) = entspricht nicht Prüfgrundlage N/A = nicht anwendbar N/T = nicht getestet Abbreviations: P(ass) = passed F(ail) = failed N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any safety mark on this or similar products.

TUV USLIGHTING

Embed Size (px)

DESCRIPTION

Certificazioni TUV Lampade ad induzione

Citation preview

Page 1: TUV USLIGHTING

TÜV Rheinland Product Safety GmbH Am Grauen Stein D - 51105 Köln Tel.: +49 221 806-1371 Fax: +49 221 806-3909 Mail: [email protected] Web: www.tuv.com Rev. 00 2006-04-01/ approved: Hongyan.yu

Produkte Products

Prüfbericht - Nr.: Test Report No.:

30980453.003 Seite 1 von 35 Page 1 of 35

Auftraggeber: Client:

US Lighting Tech

2665 Temple Avenue, Signal Hill, CA 90755 USA

Gegenstand der Prüfung: Test item:

Flood Lighiing Luminaires - Cobra Street Light Series, Diamond Wall Pack Series, Endura Garage Light Series, Parket Parking Light Series, Ridgeline High Bay Series, Acorn Post Top Exterior Series.

Bezeichnung: Identification:

1) CO-3-xxxW-5K 2) DI-3-xxxW-5K 3) EX-3-xxxW-5K or DX-3-xxxW-5K 4) PA-3-xxxW-5K 5) RI-3-xxxW-5K 6) AC-3-xxxW-5K

Where xxx = wattage and 250 W max. Refer to page 3 of the report for actual ratings

Serien-Nr.: Serial No.:

1) COxxx-000001 2) DIxxx-000001 3) EXxxx-000001 or DXxxx-000001 4) PAxxx-000001 5) RIxxx-000001

6) ACxxx-000001

Wareneingangs-Nr.: Receipt No.:

-- Eingangsdatum: Date of receipt:

April 8, 2009

Prüfort: Testing location:

1279 Quarry Lane, Ste. A, Pleasanton, CA 94566

Prüfgrundlage: Test specification:

EN 60598-2-5:1998 EN 60598-1:2004

Prüfergebnis: Test Result:

Der Prüfgegenstand entspricht oben genannter Prüfgrundlage(n). The test item passed the test specification(s).

Prüflaboratorium: Testing Laboratory:

TUV Rheinland Product Safety GmbH., Am Grauen Stein, 51105 Köln, Germany

geprüft/ tested by:

7/2/09 Jim Cheng

kontrolliert/ reviewed by:

7/2/09 Ronald Younan

Datum Date

Name/Stellung Name/Position

Unterschrift Signature

Datum Date

Name/Stellung Name/Position

Unterschrift Signature

Sonstiges/ Other Aspects:

Factory: US Lighting Tech 2665 Temple Avenue, Signal Hill, CA 90755 USA

Abkürzungen: P(ass) = entspricht Prüfgrundlage F(ail) = entspricht nicht Prüfgrundlage N/A = nicht anwendbar N/T = nicht getestet

Abbreviations: P(ass) = passed F(ail) = failed N/A = not applicable N/T = not tested

Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens.

This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any safety mark on this or similar products.

Page 2: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 2 of 35

TEST REPORT EN 60598-2-5

Part 2: Particular requirements Section Five – Floodlights

Report Reference No. ....................: Tested by (name+signature) ............: Refer to cover page ....................................................Approved by (name+signature)........: Refer to cover page ....................................................Date of issue....................................: Refer to cover page CB/CCA Testing Laboratory..........: TUV Rheinland of North America, Inc. Address............................................: 1279 Quarry Lane, Ste. A, Pleasanton, CA 94566 USA

Testing location/ address .................: 1279 Quarry Lane, Ste. A, Pleasanton, CA 94566 USA Applicant’s name ...........................: US Lighting Tech

Address............................................: 2665 Temple Avenue, Signal Hill, CA 90755 USA

Test specification: Standard ..........................................:

EN 60598-2-5:1998 used in conjunction with EN 60598-1:2004

Test procedure.................................: CB / CCA Non-standard test method…………..: N/A Test Report Form No. ....................: IECEN60598_2_5A TRF Originator .................................: Intertek Semko AB Master TRF......................................: Dated 2005-05 Copyright © 2005 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description.....................: Flood Lighiing Luminaires - Cobra Street Light Series, Diamond

Wall Pack Series, Endura Garage Light Series, Parket Parking Light Series, Ridgeline High Bay Series, Acorn Post Top Exterior Series.

Trade Mark ......................................: None Manufacturer....................................: US Lighting Tech Address ...........................................: 2665 Temple Avenue, Signal Hill, CA 90755 USA Model/Type reference ......................: 1) CO-3-xxxW-5K

2) DI-3-xxxW-5K 3) EX-3-xxxW-5K or DX-3-xxxW-5K 4) PA-3-xxxW-5K 5) RI-3-xxxW-5K 6) AC-3-xxxW-5K

Page 3: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 3 of 35

Ratings ............................................: 1) 120/277 Vac, 50/60Hz, PF 0.98, 40/80/100/150/200/250W, 0.4/0.8/1.0/1.7/2.0/2.3A max. 2) 120/277 Vac, 50/60Hz, PF 0.98, 40/80/100W, 0.4/0.8/1.0A max. 3) 120/277 Vac, 50/60Hz, PF 0.98, 40/80/100W, 0.4/0.8/1.0A max. 4) 120/277 Vac, 50/60Hz, PF 0.98, 40/80/100/150/200/250W, 0.4/0.8/1.0/1.7/2.0/2.3/A max. 5) 120/277 Vac, 50/60Hz, PF 0.98, 100/150/200/250W, 1.0/1.7/2.0/2.3A max. 6) 120/277 Vac, 50/60Hz, PF 0.98, 40/80/100/150/200/250W, 0.4/0.8/1.0/1.7/2.0/2.3/A max.

Page 4: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 4 of 35

Copy of marking plate

Page 5: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 5 of 35

Page 6: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 6 of 35

Summary of testing: IP 43 test Mechanical strength Mechanical load Grounding and bonding Endurance Temperature Insulation Resistance Electric strength

Page 7: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 7 of 35

Test item particulars................................................. : Possible test case verdicts: - test case does not apply to the test object ................ : N/A (Not applicable) - test object does meet the requirement ...................... : P (Pass) - test object does not meet the requirement ................ : F (Fail) Testing Date of receipt of test item........................................... : April 8, 2009 Date (s) of performance of tests .................................. : April 8, 2009 – July 2, 2009 General remarks: This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. This report is not valid as a CCA Test Report unless signed by an approved CCA Testing Laboratory and appended to a CCA Notification of a CCA Notification of Test Result issued by an NCB in accordance with a CCA Group Permanent Documents. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. List of test equipment must be kept on file and available for review. Throughout this report a comma (point) is used as the decimal separator. In this report requirements valid for EN only are marked with (EN). General product information: The product covered in this report are Flood Lighiing Luminaires including Cobra Street Light Series, Diamond Wall Pack Series, Endura Garage Light Series, Parket Parking Light Series, Ridgeline High Bay Series, Acorn Post Top Exterior Series. The luminaires are intended for permanent connection. All luminaires are intended for indoor and outdoor use except the Ridgeline High Bay Series are for indoor use only. The luminaires uses induction lamp.

Page 8: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 8 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

5.2 (0) GENERAL TEST REQUIREMENTS 5.2 (0.1) Information for luminaire design considered Standard

Yes No ⎯

5.2 (0.3) More sections applicable ..................................... : Yes No ⎯ 5.4 (2) CLASSIFICATION 5.4 (2.2) Type of protection...................................................: Class I ⎯ 5.4 (2.3) Degree of protection ...............................................: IPX3 ⎯ 5.4 (2.4) Luminaire only suitable for non-combustible

surfaces .................................................................:Yes No ⎯

Luminaire suitable for normally flammable surfaces: Yes No ⎯ Luminaire suitable to be covered by insulating

materials ................................................................:Yes No ⎯

5.4 (2.5) Luminaire for normal use .......................................: Yes No ⎯ Luminaire for rough service ...................................: Yes No ⎯

5.5 (3) MARKING 5.5 (3.2) Mandatory markings Position of the marking Format of symbols/text 5.5 (3.3) Additional information Language of instructions English is verified P 5.5 (3.3.1) Combination luminaires Not a combination luminaire N/A 5.5 (3.3.2) Nominal frequency in Hz 50/60Hz P 5.5 (3.3.3) Operating temperature Tw and Tc are not marked and

the wiring temperature < 90 °C

P

5.5 (3.3.4) Symbol or warning notice Not provided F 5.5 (3.3.5) Wiring diagram provided P 5.5 (3.3.6) Special conditions None N/A 5.5 (3.3.7) Metal halid lamp luminaire – warning Not MHL N/A 5.5 (3.3.8) Limitation for semi-luminaires Not semi-luminaires N/A 5.5 (3.3.9) Power factor and supply current Provided P 5.5 (3.3.10)

Suitability for use indoors Operation temperature provided

P

5.5 (3.3.11)

Luminaires with remote control No remote control N/A

Page 9: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 9 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

5.5 (3.3.12)

Clip-mounted luminaire - warning Not lip-mounted N/A

5.5 (3.3.13)

Specifications of protective shields No protective shield required N/A

5.5 (3.3.14)

Symbol for nature of supply is marked

P

5.5 (3.3.15)

Rated current of socket outlet No socket outlet N/A

5.5 (3.3.16)

Rough service luminaire Not rough service luminaire N/A

5.5 (3.3.17)

Mounting instruction for type Y, type Z and some type X attachments

No type X, Y Z attachments N/A

5.5 (3.3.18)

Non-ordinary luminaires with PVC cable Ordinary luminares N/A

5.5. (3.3.101)

Adequate warning on the package (EN) Terminal block is provided N/A

5.5 (3.4) Test with water P Test with hexane P Legible after test P Label attached P

5.6 (4) CONSTRUCTION 5.6.1 (-) At least IPx3 Tested per IPX3 P 5.6.2 (-) Lampholder brackets No lampholder, Lamp

provides the leads with a connector

N/A

5.6.3 (-) Adjusting means Not provided N/A 5.6.4 (-) Controlling components Adequate P 5.6.5 (-) Fixing device Provided P Wind force test Tested P 5.6.6 (-) Locking system No means for angular

adjustment are provided N/A

5.6.7 (-) Vibration resistance Adequate P 5.6.8 (-) Glass cover Tempted glass used P 5.6 (4.2) Components replaceable without difficulty P 5.6 (4.3) Wireways smooth and free from sharp edges P 5.6 (4.4) Lampholders 5.6 (4.4.1) Integral lampholder No lampholder N/A 5.6 (4.4.2) Wiring connection N/A 5.6 (4.4.3) Lampholder for end-to-end mounting N/A

Page 10: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 10 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

5.6 (4.4.4) Positioning N/A - pressure test (N) ...................................................: N/A -.bending test (Nm) .................................................: N/A 5.6 (4.4.5) Peak pulse voltage N/A 5.6 (4.4.6) Centre contact N/A 5.6 (4.4.7) Parts in rough service luminaires resistant to

tracking N/A

5.6 (4.4.8) Lamp connectors N/A 4.6 (4.4.9) Caps and bases correctly used N/A 5.6 (4.5) Starter holders Starter holder in luminaires other than class II No starter N/A Starter holder class II construction N/A 5.6 (4.6) Terminal blocks Tails Meet the requirements of

figure 2 P

Unsecured blocks Not provided N/A 5.6 (4.7) Terminals and supply connections 5.6 (4.7.1) Contact to metal parts All live parts are fixed in place P 5.6 (4.7.2) Test 8 mm live conductor F Test 8 mm earth conductor Not touch the live parts P 5.6 (4.7.3) Terminals for supply conductors P 5.6 (4.7.3.1)

Welded connections:

- stranded or solid conductor No welded connections N/A - spot welding N/A - welding between wires N/A - Type Z attachment N/A - mechanical test according to 15.8.2 N/A - electrical test according to 15.9 N/A - heat test according to 15.9.2.3 and 15.9.2.4 N/A 5.6 (4.7.4) Terminals other than supply connection P 5.6 (4.7.5) Heat-resistant wiring/sleeves Thermal sleeves are provided P 5.6 (4.7.6) Multi-pole plug No plug N/A - test at 30N N/A 5.6 (4.8) Switches: - adequate rating No switches provided with the

luminaire N/A

Page 11: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 11 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

- adequate fixing N/A - polarized supply N/A 5.6 (4.9) Insulating lining and sleeves 5.6 (4.9.1) Retainment Retained P Method of fixing .................................................... : Wire wrap P 5.6 (4.9.2) Insulated linings and sleeves a) & c) Insulation resistance and electric strength Need info for the insulation

sleeve P

b) Ageing test. Temperature (°C).......................... : Part of the lamp assembly P

5.6 (4.10) Insulation of Class II luminaires 5.6 (4.10.1)

No contact, mounting surface – accessible metal parts - wiring of basic insulation

Not class II luminaire N/A

Safe installation fixed luminaires N/A Capacitors and switches N/A Interference suppression capacitors according to

IEC 60384-14 N/A

5.6 (4.10.2)

Assembly gaps:

- not coincidental N/A - no straight access with test probe N/A 5.6 (4.10.3)

Retainment of insulation:

- fixed N/A - unable to be replaced; luminaire inoperative N/A - sleeves retained in position N/A - lining in lampholder N/A 5.6 (4.11) Electrical connections 5.6 (4.11.1)

Contact pressure P

5.6 (4.11.2)

Screws:

- self-tapping screws Not used N/A - thread-cutting screws Not used N/A - at least two self-tapping screws Not used N/A 5.6 (4.11.3)

Screw locking:

- spring washer Spring washer is used instead of flat washer

P

- rivets Not used N/A

Page 12: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 12 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

5.6 (4.11.4)

Material of current-carrying parts Copper used P

5.6 (4.11.5)

No contact to wood P

5.6 (4.11.6)

Electro-mechanical contact systems No Electro-mechanical Contact system

N/A

5.6 (4.12) Mechanical connections and glands 5.6 (4.12.1)

Screws not made of soft metal P

Screws of insulating material No such screws N/A Torque test: torque (Nm); part .............................. : Torque test: torque (Nm); part .............................. : Torque test: torque (Nm); part .............................. : 5.6 (4.12.2)

Screws with diameter < 3 mm screwed into metal > 3mm P

5.6 (4.12.4)

Locked connections:

- fixed arms; torque (Nm)...................................... : No fixed arms N/A - lampholder; torque (Nm)..................................... : No lampholder N/A - push-button switches; torque 0,8 Nm ................. : No push-button switches N/A 5.6 (4.12.5)

Screwed glands; force (N) .................................... : No screwed glands N/A

5.6 (4.13) Mechanical strength 5.6 (4.13.1)

Impact tests:

- fragile parts; energy (Nm)................................... : 0.5 P - other parts; energy (Nm) .................................... : 0.7 P 1) live parts No live parts are accessible P 2) linings Not impaired P 3) protection Adequately protection

remained P

4) covers Not broke P 5.6 (4.13.3)

Straight test finger Tested with 30N P

5.6 (4.13.4)

Rough service luminaires

- IP 54 or higher Not rough service luminaires N/A a) fixed N/A b) hand-held N/A

Page 13: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 13 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

c) delivered with a stand N/A d) for temporary installations and suitable for

mounting on a stand N/A

5.6 (4.13.6)

Tumbling barrel None N/A

5.6 (4.14) Suspensions and adjusting devices 5.6 (4.14.1)

Mechanical load:

A) four times the weight P B) torque 2,5 Nm P C) bracket arm; bending moment (Nm) ................ : < 1.0 Nm P D) load track-mounted luminaires Not track-mounted luminaire N/A E) clip-mounted luminaires, glass-shelve.

Thickness (mm) .................................................... : Not clip-mounted luminaire N/A

metal rod. Diameter (mm)..................................... : N/A 5.6 (4.14.2)

Load to flexible cables

Mass (kg).............................................................. : No flexible cable provided N/A Stress in conductors (N/mm²) ............................... : N/A 5.6 (4.14.3)

Adjusting devices:

- flexing test; number of cycles ............................. : Not provided N/A - strands broken N/A - electric strength test afterwards N/A 5.6 (4.14.4)

Telescopic tubes: cords not fixed to tube; no strain on conductors

No telescopic tubes N/A

5.6 (4.14.5)

Guide pulleys No pulleys N/A

5.6 (4.14.6)

Strain on socket-outlets No socket-outlets N/A

5.6 (4.15.1)

Flammable materials:

- glow-wire test 650 °C Polymeric material does not have insulation function

N/A

- spacing ≥ 30 mm Have space >30 mm P

- screen withstanding test of 13.3.1 No screen provided N/A - screen dimensions N/A - no fiercely burning material P

Page 14: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 14 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

- thermal protection No temperature sensor provided

N/A

- electronic circuits exempted Noted P 5.6 (4.15.2)

Luminaires made of thermoplastic material with lamp control gear

a) construction Not made of thermoplastic N/A b) temperature sensing control Not provided N/A c) surface temperature Refer to temperature test P 5.6 (4.16) Luminaires marked with F-symbol No lamp control gear (compliance with Section 12)

Electronic lamp control gear used

P

5.6 (4.16.1)

Lamp control gear spacing:

- spacing 35 mm Exempted for electronic lamp control gear

N/A

- spacing 10 mm See above N/A 5.6 (4.16.2)

Thermal protection:

- in lamp control gear See above N/A - external See above N/A - fixed position See above N/A - temperature marked lamp control gear See above N/A 5.6 (4.16.3)

"F" curve measured See above N/A

5.6 (4.17) Drain holes Watertight, no drain holes N/A Clearance at least 5 mm N/A 5.6 (4.18) Resistance to corrosion: 5.6 (4.18.1)

- rust-resistance Powder coated and non-corrosion material used

P

5.6 (4.18.2)

- season cracking in copper No rolled copper N/A

5.6 (4.18.3)

- corrosion of aluminium Powder coated luminium P

5.6 (4.19) Igniters compatible with ballast No igniters N/A 5.6 (4.20) Rough service vibration Not rough service luminaire N/A 5.6 (4.21) Protective shield: 5.6 (4.21.1)

Shield fitted Not for tungsten halogen lamps

N/A

Page 15: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 15 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

5.6 (4.21.2)

Particles from a shattering lamp not impair safety N/A

5.6 (4.21.3)

No direct path N/A

5.6 (4.21.4)

Impact test on shield N/A

Glow-wire test on lamp compartment N/A 5.6 (4.22) Attachments to lamps N/A 5.6 (4.23) Semi-luminaires comply class II N/A 5.6 (4.24) UV radiation, metal halide lamps N/A 5.6 (4.25) No sharp point or edges N/A 5.6 (4.26) Short-circuit protection: N/A 5.6 (4.26.1)

Uninsulated accessible SELV parts N/A

5.6 (4.26.2)

Short-circuit test N/A

5.6 (4.26.3)

Test chain according to Figure 29 N/A

5.7 (11) CREEPAGE DISTANCES AND CLEARANCES Working voltage (V) ................................... : 277 V ⎯ Voltage form Sinusoidal

Non-sinusoidal ⎯

PTI < 600 > 600 ⎯ Rated pulse voltage (kV) ...................................... : Not rated ⎯ (1) Current-carrying parts of different polarity: cr

(mm); cl (mm) ....................................................... : Cr: > 5mm cl: > 3mm P

(2) Current-carrying parts and accessible parts: cr (mm); cl (mm) ....................................................... :

Cr: > 5mm cl: > 3mm P

(3) Parts becoming live due to breakdown of basic insulation and metal parts: cr (mm); cl (mm) ................................................... :

Cr: > 5mm cl: > 3mm P

(4) Outer surface of cable where it is clamped and metal parts: cr (mm); cl (mm)................................ :

No such cables N/A

(5) Not used ⎯ (6) Current-carrying parts and supporting surface:

cr (mm); cl (mm) ................................................... : Cr: > 5mm cl: > 3mm P

5.8 (7) PROVISION FOR EARTHING 5.8 (7.2.1 + 7.2.3)

Accessible metal parts P

Page 16: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 16 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

Metal parts in contact with supporting surface Bonded to grounding P Resistance < 0,5 Ω P

Two self-tapping screws used Not used N/A Thread-forming screw used in a grove Not used N/A Earth makes contact first P 5.8 (7.2.2 + 7.2.3)

Earth continuity in joints etc. P

5.8 (7.2.4) Locking of clamping means P Compliance with 4.7.3 P 5.8 (7.2.5) Earth terminal integral part of connector socket No socket N/A 5.8 (7.2.6) Earth terminal adjacent to mains terminals For fixed wiring N/A 5.8 (7.2.7) Electrolytic corrosion of the earth terminal P 5.8 (7.2.8) Material of earth terminal Metal ring connector P Contact surface bare metal P 5.8 (7.2.10)

Class II luminaire for looping-in Not class II luminaire N/A

Double or reinforced insulation to functional earth N/A 5.8 (7.2.11)

Earthing core coloured green-yellow No supply cord N/A

Length of earth conductor N/A 5.9 (14) SCREW TERMINALS Separately approved; component list (see Annex 1) P Part of the luminaire (see Annex 3) P

5.9 (15) SCREWLESS TERMINALS Separately approved; component list Not provided (see Annex 1) N/A Part of the luminaire (see Annex 4) N/A

5.10 (5) EXTERNAL AND INTERNAL WIRING 5.10 (5.2) Supply connection and external wiring 5.10 (5.2.1)

Means of connection ............................................ : Fix wiring - terminal provided P

Connecting leads (EN) Not provided N/A - without a means for connection to the supply A means for connection

provided N/A

- terminal block specified Provided within the luminaire P - relevant information provided P

Page 17: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 17 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

- compliance with 4.6, 4.7.1, 4.7.2, 4.10.1, 11.2, 12 and 13.2 of Part 1

P

5.10 (5.2.2)

Type of cable........................................................ : No cables provided N/A

Cables equal to HD 21 S2 or HD22 S2 (EN) N/A Nominal cross-sectional area (mm²) ..................... : N/A 5.10 (5.2.3)

Type of attachment, X, Y or Z For fixed wiring N/A

5.10 (5.2.5)

Type Z not connected to screws N/A

5.10 (5.2.6)

Cable entries: N/A

- suitable for introduction N/A - adequate degree of protection N/A 5.10 (5.2.7)

Cable entries through rigid material have rounded edges

N/A

5.10 (5.2.8)

Insulating bushings: N/A

- suitably fixed N/A - material in bushings N/A - material not likely to deteriorate N/A - tubes or guards made of insulating material N/A 5.10 (5.2.9)

Locking of screwed bushings N/A

5.10 (5.2.10)

Cord anchorage: N/A

- covering protected from abrasion N/A - clear how to be effective N/A - no mechanical or thermal stress N/A - no tying of cables into knots etc. N/A - insulating material or lining N/A 5.10 (5.2.10.1)

Cord anchorage for type X attachment: N/A

a) at least one part fixed N/A b) types of cable N/A c) no damaging of the cable N/A d) whole cable can be mounted N/A e) no touching of clamping screws N/A f) metal screw not directly on cable N/A

Page 18: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 18 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

g) replacement without special tool N/A Glands not used as anchorage N/A Labyrinth type anchorages N/A 5.10 (5.2.10.2)

Adequate cord anchorage for type Y and type Z attachment

N/A

5.10 (5.2.10.3)

Tests: N/A

- impossible to push cable; unsafe N/A - pull test: 25 times; pull (N) .................................. : N/A - torque test: torque (Nm) ..................................... : N/A - displacement ≤ 2 mm N/A

- no movement of conductors N/A - no damage of cable or cord N/A 5.10 (5.2.11)

External wiring passing into luminaire Same as internal wiring P

5.10 (5.2.12)

Looping-in terminals No looping in terminals N/A

5.10 (5.2.13)

Wire ends not tinned Not tinned P

Wire ends tinned: no cold flow N/A 5.10 (5.2.14)

Mains plug same protection No plug N/A

Class III luminaire plug Not class III luminaire N/A 5.10 (5.2.16)

Appliance inlets (IEC 60320) No inlet N/A

Appliance couplers of class II type Not class II luminaire N/A 5.10 (5.2.17)

Non standardized interconnecting cables properly assembled

No interconnecting cables N/A

5.10 (5.2.18)

Used plug in accordance with:

No Plug N/A

- IEC 60063 N/A - other standard N/A 5.10 (5.3) Internal wiring 5.10 (5.3.1)

Internal wiring of suitable size and type Suitable wire used P

Through wiring - not delivered/ mounting instruction No through wiring provided N/A - factory assembled Factory assembled P - socket outlet loaded (A)...................................... : No socket outlet N/A

Page 19: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 19 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

- temperatures ...................................................... : (see Annex 2) P Green-yellow for earth only P 5.10 (5.3.1.1)

Internal wiring connected directly to fixed wiring

Cross-sectional area (mm²) .................................. : 18 AWG / 0.75 mm² P Insulation thickness P Extra insulation added where necessary Not added N/A 5.10 (5.3.1.2)

Internal wiring connected to fixed wiring via internal current-limiting device

Adequate cross-sectional area and insulation thickness

No such internal wiring N/A

5.10 (5.3.1.3)

Double or reinforced insulation for class II Not class II luminaire N/A

5.10 (5.3.1.4)

Conductors without insulation Not used N/A

5.10 (5.3.1.5)

SELV current-carrying parts No SELV circuit N/A

5.10 (5.3.1.6)

Insulation thickness other than PVC or rubber P

5.10 (5.3.2)

Sharp edges etc. Routed away from sharp edges

P

No moving parts of switches etc. No moving parts N/A Joints, raising/lowering devices P Telescopic tubes etc. None N/A No twisting over 360° P

5.10 (5.3.3)

Insulating bushings:

- suitable fixed No bushings N/A - material in bushings N/A - material not likely to deteriorate N/A - cables with protective sheath N/A 5.10 (5.3.4)

Joints and junctions effectively insulated No such joints N/A

5.10 (5.3.5)

Strain on internal wiring No such strain provided N/A

5.10 (5.3.6)

Wire carriers No wire carriers N/A

5.10 (5.3.7)

Wire ends not tinned Not tinned P

Wire ends tinned: no cold flow N/A

Page 20: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 20 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

5.11 (8) PROTECTION AGAINST ELECTRIC SHOCK 5.11 (8.2.1) Live parts not accessible No live parts are accessible P Basic insulated parts not used on the outer

surface without appropriate protection P

Protection in any position P Double-ended tungsten filament lamp Not used N/A Insulation lacquer not reliable P Double-ended high pressure discharge lamp Not used N/A Relevant warning according to 3.2.18 fitted to the

luminaire N/A

5.11 (8.2.2) Portable luminaire adjusted in most unfavourable position

Not portable luminaire N/A

5.11 (8.2.3) Class II luminaire: - basic insulated metal parts not accessible during

starter or lamp replacement Not class II luminaire N/A

- basic insulation not accessible other than during starter or lamp replacement

N/A

- glass protective shields not used as supplementary insulation

N/A

Class I luminaire with BC lampholder N/A 5.11 (8.2.4) Portable luminaire: - protection independent of supporting surface Not portable luminiares N/A - terminal block completely covered N/A 5.11 (8.2.5) Compliance with the standard test finger or

relevant probe P

5.11 (8.2.6) Covers reliably secured P 5.11 (8.2.7) Discharging of capacitors ≥ 0,5 µF No discharging capacitors N/A

Portable plug connected luminaire with capacitor N/A Other plug connected luminaire with capacitor N/A Discharge device on or within capacitor N/A Discharge device mounted separately N/A

5.12 (12) ENDURANCE TEST AND THERMAL TEST 5.12 (12.3) Endurance test: - mounting-position ............................................... : As intended ⎯ - test temperature (°C).......................................... : 25 °C ambient ⎯ - total duration (h) ................................................. : 168 h ⎯

Page 21: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 21 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

- supply voltage: Un factor; calculated voltage (V) ............................................................................. :

- lamp used........................................................... : As provided ⎯ 5.12 (12.3.2)

After endurance test:

- no part unserviceable P - luminaire not unsafe P - no damage to track system Not tracking luminaire N/A - marking legible P - no cracks, deformation etc. P 5.12 (12.4) Thermal test (normal operation) (see Annex 2) P 5.12.1 (-) Temperature reduction P 5.12 (12.5) Thermal test (abnormal operation) (see Annex 2) P 5.12 (12.6) Thermal test (failed lamp control gear condition): 4.12 (12.6.1)

Through wiring or looping-in wiring loaded by a current of (A) ....................................................... :

No through wiring or looping-

in wiring. Marked with Refer to 4.16.1

- case of abnormal conditions............................... : Per 4.16 the electronic lamp control gear are exempt

- measured winding temperature (°C): at 1,1 Un .. : See above ⎯ - measured mounting surface temperature

(°C): at 1,1 Un ...................................................... : See above N/A

- calculated mounting surface temperature (°C) ... : See above N/A

- track-mounted luminaires Not track-mounted N/A 5.12 (12.6.2)

Temperature sensing control

- case of abnormal conditions............................... : No temperature sensing control

- thermal link N/A - manual reset cut-out N/A - auto reset cut-out N/A - measured mounting surface temperature (°C) ... : N/A

- track-mounted luminaires N/A 5.12 (12.7) Thermal test (failed lamp control gear in plastic luminaires): 4.12 (12.7.1)

Through wiring or looping-in wiring loaded by a current of (A) ....................................................... :

Metal housing used ⎯

- case of abnormal conditions............................... : ⎯

Page 22: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 22 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

5.12 (12.7.1)

- measured winding temperature (°C) at 1,1 Un ... : ⎯

- measured temperature of fixing point/ exposed part (°C) at 1,1 Un ................................................ :

N/A

- calculated temperature of fixing point/ exposed part (°C) ............................................................... :

N/A

5.12 (12.7.2)

Temperature sensing control

- thermal link No temperature sensing control

N/A

- manual reset cut-out N/A - auto reset cut-out N/A - measured temperature of fixing point/ exposed

part (°C) ............................................................... : N/A

5.13 (9) RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE 5.13 (9.2) Tests for ingress of dust, solid objects and moisture: - classification according to IP .............................. : IPX3 ⎯ - mounting position during test.............................. : Normal use ⎯ - fixing screws tightened; torque (Nm) .................. : ⎯ - tests according to clauses .................................. : IEC 60529 ⎯ - electric strength test afterwards P a) no deposit in dust-proof luminaire Not dust proof N/A b) no talcum in dust-tight luminaire N/A c) no trace of water on current-carrying parts or

where it could become a hazard P

d) i) For luminaires without drain holes – no water entry

P

d) ii) For luminaires with drain holes – no hazardous water entry

No drain holes N/A

e) no water in watertight luminaire P f) no contact with live parts (IP 2X) N/A f) no entry into enclosure (IP 3X and IP 4X) P f) no contact with live parts (IP 3X and IP 4X) P 5.13 (9.3) Humidity test 48 h P

5.14 (10) INSULATION RESISTANCE AND ELECTRIC STRENGTH 5.14 (10.2.1)

Insulation resistance test

Page 23: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 23 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

Cable or cord covered by metal foil or replaced by a metal rod of mm Ø ............................................ :

-

Insulation resistance (MΩ): > 2 MΩ P SELV: - between current-carrying parts of different polarity

............................................................................. : No SELV N/A

- between current-carrying parts and mounting surface.................................................................. :

N/A

- between current-carrying parts and metal parts of the luminaire......................................................... :

N/A

Other than SELV: - between live parts of different polarity ................ : P - between live parts and mounting surface ........... : P - between live parts and metal parts ..................... : P - between live parts of different polarity through

action of a switch .................................................. : N/A

5.14 (10.2.2)

Electric strength test

Dummy lamp P Luminaires with igniters after 24 h test No igniters N/A Luminaires with manual igniters N/A Test voltage (V): N/A SELV: - between current-carrying parts of different polarity

............................................................................. : No SELV N/A

- between current-carrying parts and mounting surface.................................................................. :

N/A

- between current-carrying parts and metal parts of the luminaire......................................................... :

N/A

Other than SELV: - between live parts of different polarity ................ : 1000 + 2x277 = 1554 Vac P - between live parts and mounting surface ........... : 1000 + 2x277 = 1554 Vac P - between live parts and metal parts ..................... : 1000 + 2x277 = 1554 Vac P - between live parts of different polarity through

action of a switch .................................................. : No action switch N/A

5.14 (10.3.1)

Leakage current (mA)........................................... : < 1.0 mA P

5.15 (13) RESISTANCE TO HEAT, FIRE AND TRACKING

Page 24: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 24 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

5.15 (13.2.1)

Ball-pressure test:

- part tested; temperature (°C).............................. : Part of approved component, test was not carried out

N/A

- part tested; temperature (°C).............................. : N/A

5.15 (13.3.1)

Needle flame test (10 s):

- part tested .......................................................... : Part of approved component, test was not carried out

N/A

- part tested .......................................................... : N/A 5.15 (13.3.2)

Glow-wire test (650°C):

- part tested .......................................................... : Part of approved component, test was not carried out

N/A

- part tested .......................................................... : N/A 5.15 (13.4.1)

Tracking test: part tested ...................................... : Part of approved component, test was not carried out

N/A

Page 25: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 25 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

ZB ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN) (3.3) DK: power supply cord with label No power supply cord N/A IT: warning label on Class 0 luminaire N/A (4.5.1) DK: socket-outlets No socket-outlets N/A (5.2.1) CY, DK, FI, SE, GB: type of plug N/A

ZC ANNEX ZC, NATIONAL DEVIATIONS (EN) (13.3) DK: Needle flame test during 30 s Part of approved component,

test was not carried out N/A

(13.3) GB: Requirements according to United Kingdom Building Regulation

N/A

(13.3.2) FR: Glow-wire test 850°C alt. 750°C for luminaires in premises open to public or 960°C for luminaires in emergency exits

N/A

Page 26: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 26 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

ANNEX 1: components P object/part No. code manufacturer/

trademark type/model technical data standard mark(s) of

conformity Cobra Street Light Series

Input Terminal Marathon ½ inch sectional

600V, 70A, 105ºC

UL 486A-486B CSA-C22.2 No. 158

UL, CSA, CE

Earthing Terminal Connector

Molex 190740033 22-18AW, #10 Stud size

UL 486A-486B CSA-C22.2 No. 158

UL, CSA

Ballast US Energy Technologies Inc.

WJY40DH01 120-277Vac, 50/60 Hz, 40W, 0.16-0.38A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY80DH01 120-277Vac, 50/60 Hz, 80W, 0.32-0.75A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY100DH01 120-277Vac, 50/60 Hz, 100W, 0.41-0.88A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY150DH01 120-277Vac, 50/60 Hz, 150W, 0.63-1.33A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY200DH01 120-277Vac, 50/60 Hz, 200W, 0.80-1.76A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY250DH01 120-277Vac, 50/60 Hz, 250W, 1.05-2.19A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Internal Wire any any 18AWG, 105ºC, 600V

UL 758 CSA-C22.2 No. 127

UL, CSA

Page 27: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 27 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

Glass Cover any any Tempted Glass

-- --

Lamp Reflector any any Aluminum sheet, 0.33 mm thick

-- --

Gasket any any Silicon rubber -- -- Diamond Wall Pack Series

Input Terminal Marathon ½ inch sectional

600V, 70A, 105ºC

UL 486A-486B CSA-C22.2 No. 158

UL, CSA, CE

Earthing Terminal Connector

Molex 190740033 22-18AW, #10 Stud size

UL 486A-486B CSA-C22.2 No. 158

UL, CSA

Ballast US Energy Technologies Inc.

WJY40DH01 120-277Vac, 50/60 Hz, 40W, 0.16-0.38A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY80DH01 120-277Vac, 50/60 Hz, 80W, 0.32-0.75A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY100DH01 120-277Vac, 50/60 Hz, 100W, 0.41-0.88A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Internal Wire any any 18AWG, 105ºC, 600V

UL 758 CSA-C22.2 No. 127

UL, CSA

Glass Cover any any Tempted Glass

-- --

Lamp Reflector any any Aluminum sheet, 0.33 mm thick

-- --

Gasket any any Silicon rubber -- -- Endura Garage Light Series

Page 28: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 28 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

Input Terminal Marathon ½ inch sectional

600V, 70A, 105ºC

UL 486A-486B CSA-C22.2 No. 158

UL, CSA, CE

Earthing Terminal Connector

Molex 190740033 22-18AW, #10 Stud size

UL 486A-486B CSA-C22.2 No. 158

UL, CSA

Ballast US Energy Technologies Inc.

WJY40DH01 120-277Vac, 50/60 Hz, 40W, 0.16-0.38A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY80DH01 120-277Vac, 50/60 Hz, 80W, 0.32-0.75A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY100DH01 120-277Vac, 50/60 Hz, 100W, 0.41-0.88A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Internal Wire any any 18AWG, 105ºC, 600V

UL 758 CSA-C22.2 No. 127

UL, CSA

Cover any any Polymeric HB UL 94 UL Lamp Reflector any any Aluminum

sheet, 0.33 mm thick

-- --

Gasket any any Silicon rubber -- -- Parker Parking Light Series

Input Terminal Marathon ½ inch sectional

600V, 70A, 105ºC

UL 486A-486B CSA-C22.2 No. 158

UL, CSA, CE

Earthing Terminal Connector

Molex 190740033 22-18AW, #10 Stud size

UL 486A-486B CSA-C22.2 No. 158

UL, CSA

Ballast US Energy Technologies Inc.

WJY40DH01 120-277Vac, 50/60 Hz, 40W, 0.16-0.38A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Page 29: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 29 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

Ballast US Energy Technologies Inc.

WJY80DH01 120-277Vac, 50/60 Hz, 80W, 0.32-0.75A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY100DH01 120-277Vac, 50/60 Hz, 100W, 0.41-0.88A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY150DH01 120-277Vac, 50/60 Hz, 150W, 0.63-1.33A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY200DH01 120-277Vac, 50/60 Hz, 200W, 0.80-1.76A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY250DH01 120-277Vac, 50/60 Hz, 250W, 1.05-2.19A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Internal Wire any any 18AWG, 105ºC, 600V

UL 758 CSA-C22.2 No. 127

UL, CSA

Glass Cover any any Tempted Glass

-- --

Lamp Reflector any any Aluminum sheet, 0.33 mm thick

-- --

Gasket any any Silicon rubber -- -- Ridgeline High Bay Series

Input Terminal Marathon ½ inch sectional

600V, 70A, 105ºC

UL 486A-486B CSA-C22.2 No. 158

UL, CSA, CE

Earthing Terminal Connector

Molex 190740033 22-18AW, #10 Stud size

UL 486A-486B CSA-C22.2 No. 158

UL, CSA

Page 30: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 30 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

Ballast US Energy Technologies Inc.

WJY100DH01 120-277Vac, 50/60 Hz, 100W, 0.41-0.88A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY150DH01 120-277Vac, 50/60 Hz, 150W, 0.63-1.33A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY200DH01 120-277Vac, 50/60 Hz, 200W, 0.80-1.76A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY250DH01 120-277Vac, 50/60 Hz, 250W, 1.05-2.19A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Internal Wire any any 18AWG, 105ºC, 600V

UL 758 CSA-C22.2 No. 127

UL, CSA

Lamp Reflector any any Aluminum sheet, 0.33 mm thick

-- --

Lamp Reflector any any Polymeric HB UL 94 UL Gasket any any Silicon rubber -- -- Acorn Post Top Exterior Series

Input Terminal Marathon ½ inch sectional

600V, 70A, 105ºC

UL 486A-486B CSA-C22.2 No. 158

UL, CSA, CE

Earthing Terminal Connector

Molex 190740033 22-18AW, #10 Stud size

UL 486A-486B CSA-C22.2 No. 158

UL, CSA

Ballast US Energy Technologies Inc.

WJY40DH01 120-277Vac, 50/60 Hz, 40W, 0.16-0.38A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Page 31: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 31 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

Ballast US Energy Technologies Inc.

WJY80DH01 120-277Vac, 50/60 Hz, 80W, 0.32-0.75A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Ballast US Energy Technologies Inc.

WJY100DH01 120-277Vac, 50/60 Hz, 100W, 0.41-0.88A, 122 ºF, PF = or >0.95

IEC 60929/IEC 61347-2-3/ IEC 61000-3-2

UL

Internal Wire any any 18AWG, 105ºC, 600V

UL 758 CSA-C22.2 No. 127

UL, CSA

Cover any any Polymeric HB UL 94 UL Lamp Reflector any any Aluminum

sheet, 0.33 mm thick

-- --

Lamp Reflector any any Polymeric HB UL 94 UL Gasket any any Silicon rubber -- --

The codes above have the following meaning: A - The component is replaceable with another one, also certified, with equivalent characteristics B - The component is replaceable if authorised by the test house C - Integrated component tested together with the appliance D - Alternative component

Page 32: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 32 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

ANNEX 2: temperature measurements, thermal tests of Section 12 P Type reference ..................................................... : Garge Lighting / Warehouse

Lighting ⎯

Lamp used............................................................ : Supplied by the factory ⎯ Lamp control gear used ........................................ : Listed in the component list ⎯ Mounting position of luminaire .............................. : Surface / hook mounted ⎯ Supply wattage (W) .............................................. : 100W ⎯ Supply current (A)................................................. : 0.8A / 0.4A (120V/277V) ⎯ Calculated power factor ........................................ : 1 ⎯ Table: measured temperatures corrected for ta = 40 °C: P

- abnormal operating mode................................... : Not carried out since the ballast is approved, no lampholder and special lamp used.

- test 1: rated voltage............................................ : 120/277 V ⎯ - test 2: 1,06 times rated voltage or 1,05 times

rated wattage........................................................ : 127/293 V ⎯

- test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage............................... :

No socket-outlets ⎯

- test 4: 1,1 times rated voltage or 1,05 times rated wattage................................................................. :

Not carried out since the ballast is approved, no lampholder and special lamp used.

Through wiring or looping-in wiring loaded by a current of A during the test .................................. :

Not throught wiring or looping in wiring

temperature (°C) of part clause 12.4 – normal (°C) clause 12.5 – abnor-mal

test 1 test 2 test 3 limits test 4 limit Mounting Surface 63 65 -- 90 -- -- Wring Box 63 65 -- 70 -- -- Enclosure 63 65 -- 70 -- -- Input Wire 63 65 -- 105 -- -- Terminal 59 69 -- 105 -- -- Ballast 75 80 -- 100 -- -- Internal Wire 56 58 -- 105 -- -- Lamp Reflect 80 82 -- 85 -- --

Page 33: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 33 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

ANNEX 3: screw terminals (part of the luminaire) P

(14) SCREW TERMINALS P (14.2) Type of terminal.................................................... : PE terminal ⎯ Rated current (A) .................................................. : Not rated ⎯ (14.3.2.1) One or more conductors One conductor P

(14.3.2.2) Special preparation P (14.3.2.3) Terminal size P Cross-sectional area (mm²) .................................. : 11.3 mm² P (14.3.3) Conductor space (mm) ......................................... : 18 AWG / 0.75 mm P (14.4) Mechanical tests P (14.4.1) Minimum distance Not pillar terminals N/A (14.4.2) Cannot slip out P (14.4.3) Special preparation P (14.4.4) Nominal diameter of thread (metric ISO thread) ... : 3.8 mm P External wiring P No soft metal No soft metal P (14.4.5) Corrosion P (14.4.6) Nominal diameter of thread (mm) ......................... : 3.8 mm P Torque (Nm) ......................................................... : 1.2 Nm P (14.4.7) Between metal surfaces Lug terminal P Mantle terminal Not mantle terminal N/A Pull test; pull (N) ................................................... : 30 N P (14.4.8) Without undue damage P

Page 34: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 34 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

ANNEX 4: screwless terminals (part of the luminaire) N/A (15) SCREWLESS TERMINALS N/A (15.2) Type of terminal.................................................... : Not provided ⎯ Rated current (A) .................................................. : ⎯ (15.3.1) Material N/A (15.3.2) Clamping N/A (15.3.3) Stop N/A (15.3.4) Unprepared conductors N/A (15.3.5) Pressure on insulating material N/A (15.3.6) Clear connection method N/A (15.3.7) Clamping independently N/A (15.3.8) Fixed in position N/A (15.3.10) Conductor size N/A Type of conductor N/A (15.5.1) Terminals internal wiring N/A (15.5.1.1) Pull test spring-type terminals (4 N, 4 samples) N/A (15.5.1.2) Pull test pin or tab terminals (4 N, 4 samples) N/A Insertion force not exceeding 50 N N/A (15.5.2) Permanent connections: pull-off test (20 N) N/A (15.6) Electrical tests N/A Voltage drop (mV) after 1 h (4 samples) .............. : N/A Voltage drop of two inseparable joints N/A Number of cycles................................................. : ⎯ Voltage drop (mV) after 10th alt. 25th cycle

(4 samples).......................................................... : N/A

Voltage drop (mV) after 50th alt. 100th cycle (4 samples).......................................................... :

N/A

After ageing, voltage drop (mV) after 10th alt. 25th cycle (4 samples)......................................... :

N/A

After ageing, voltage drop (mV) after 50th alt. 100th cycle (4 samples)....................................... :

N/A

(15.7) Terminals external wiring N/A Terminal size and rating N/A (15.8.1) Pull test spring-type terminals or welded

connections (4 samples); pull (N) ........................ : N/A

Pull test pin or tab terminals (4 samples); pull (N)..: N/A

Page 35: TUV USLIGHTING

Test Report No.: 30980453.0033

Page 35 of 35

EN 60598-2-5

Cl. Requirement − Test Result Verdict

(15.9) Contact resistance test N/A Voltage drop (mV) after 1 h terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Voltage drop of two inseparable joints Voltage drop after 10th alt. 25th cycle Max. allowed voltage drop (mV) ................ : ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Voltage drop after 50th alt. 100th cycle Max. allowed voltage drop (mV) ................ : ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Continued ageing: voltage drop after 10th alt. 25th cycle Max. allowed voltage drop (mV) ................ : ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Continued ageing: voltage drop after 50th alt. 100th cycle Max. allowed voltage drop (mV) ................ : ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV)