Troubleshooting of Demin Plant

Embed Size (px)

Citation preview

  • 8/13/2019 Troubleshooting of Demin Plant

    1/8

    Troubleshooting of DM plant

    Go to Top

    Defects Causes Remedies

    Decrease in capacity betweentwo successive regenerations

    a. Increase in ionic load

    b. Flow recorder defective

    c. Insufficient chemicals used

    d. Resin dirty

    e. Plant being used intermittently

    f. Channelling in bed

    g.Resin fouled

    h.Resin deteriorated

    i. Resin quantity insufficient in unit

    Check by analysis

    Check

    Check

    Give prolonged backwash

    void this

    Check and ensure uniformdistribution !collection

    If cation" give #Cl wash$ if anion" resin

    give alkaline brine treatment

    Check and replace charge

    Check and top up

    http://var/www/Documents%20and%20Settings/5933/Desktop/FAQs/sundaram/FAQ_DMplant.htm#c1http://var/www/Documents%20and%20Settings/5933/Desktop/FAQs/sundaram/FAQ_DMplant.htm#c1
  • 8/13/2019 Troubleshooting of Demin Plant

    2/8

    Treated quality not upto thestandard

    a. Cation e%hausted

    b. nion e%hausted

    c. &i%ed bed e%hausted

    d. &' resin not in uniform mi%ed state

    e. (ome valves like backwash leaking

    f. )a slip from cation high

    g. (i*+ slip from anion high

    h. ,nit idle

    i. ,nit not sufficiently rinsed

    -. %cessive!low flow rate

    k. Channelling

    l. Resin fouled

    m.

    Resin deteriorated

    Check

    Check

    Check

    Repeat air mi% and rinse

    Check

    Check raw water analysis$ change in)a!/ and (i*+!/ ratio$ use morechemicals

    Check raw water analysis$ change in)a!/ and (i*+!/ ratio$ use morechemicals

    Check

    Rinse to satisfactory quality

    d-ust to between unit min!ma% flowrate

    Check and ensure uniformcollection!distribution

    Check resin and give alkaline brine!#C0 treatment

    Check resin and replace

  • 8/13/2019 Troubleshooting of Demin Plant

    3/8

    Mixed bed quality not good a. Resin not separated during backwash properly

    b. ir mi% not proper

    c. Final rinse not proper

    d. (ome valves may be leaking and contaminatingthe treated water

    Give e%tended backwash aftere%hausting the bed

    Repeat

    Repeat

    Check and e%amine

    High residual C! fromdegasser

    a. It can be due to choked suction filter of degasserair blower

    b. Improper air flow to the degasser

    c. 1egasser blower not in operation

    d. ir seal not fitted!broken resulting in shortcirculating of air

    Check and clean filter

    Check damper" speed of blower"

    discharge pressure

    Check and operate blower

    Check and replace fitting

  • 8/13/2019 Troubleshooting of Demin Plant

    4/8

    "nit rinse ta#es long time a. Flow rate too high

    b. ,nit e%hausted

    c. 'ackwash valve passing

    d. nion resin organically fouled

    e. &' air mi% not satisfactory

    f. cid!alkali pockets formed in unit

    Increase flow rate

    Regenerate unit

    Check and rectify

    Give alkaline brine treatment

    Carry out air mi% once again

    Faulty design check and rectify./emporarily backwash 2followed by airscour if &'3 and rinse again

    $low rate too less a. Choked valve and suction strainer of pump

    b. Cavitation in the pump

    c. 0ow inlet pressure

    d. 1istribution or collecting system choked

    e. Resin trap at outlet choked

    f. Control valve shut due to low off4take

    Check

    Check

    Check4pump

    Check

    Check and clean

    Increase off4take

  • 8/13/2019 Troubleshooting of Demin Plant

    5/8

    %ressure drop across the bedincreasing day by day

    a. 1efective valves

    b. Packed resin bed and resin fines present

    c. Collecting system choked

    d. Pressure gauge defective

    Check

    Give e%tended backwash with openmanhole and scrap off fines from topsurface of the resin

    Check" repeat backwash

    Check and rectify! replace

    $looding in degasser a. 5ery high air flow rate

    b. Packed tower chocked due to dirt or broken

    packing material

    Reduce air flow rate by ad-ustingdamper

    *pen and check

    Resin being lost a. %cessive backwash pressure

    b. Faulty collecting system

    c. Inlet strainer damaged

    Check inlet pressure and reduce if

    necessary

    %amine same for breakage

    Check and replace

  • 8/13/2019 Troubleshooting of Demin Plant

    6/8

    &'ector not wor#ing a. 0ow power water pressure

    b. ir lock in the unit

    c. Choked or defective valves

    d. -ector no66le may be choked

    e. /oo much back pressure from the unit

    f. 'ulge in pipe lining

    Check

    'ackwash 7 open air release

    %amine and rectify

    Check

    Check for chokage of collectingsystem$ passage of inlet!outlet valves

    Check and rectify

    (ncorrect reading rota)meters

    a. Chocked orifice lines!orifice

    b. 1irty glass and float

    Check and clean

    check and clean

    (mproper reading from flowrecorder integrator

    a. Choked impulse lines!orifice

    b. 1P transmitter requires recalibration

    c. 0eakage in signal tube between transmitter andpanel

    d. 0ow air pressure for 1P transmitter or recorder

    Check and clean

    Recalibrate

    Check

    Check

  • 8/13/2019 Troubleshooting of Demin Plant

    7/8

    *evel electrodes system formeasuring and dilution tan#

    not functioning properly

    a. Improper contact between electrodes and controlcabling

    b. (horting of the two electrodes due to moisture orany foreign material

    c. Improper working of the level controllers

    Check contact and rectify

    Check and dry the contacts of moistureand dirt

    Check

    *ea#age from acidin'ection+unloading+transferpumps

    a. Improper ad-ustment of the mechanical seal

    b. 0ow strength of sulphuric and presence of ferroussulphate

    Check and ad-ust

    Check concentration and takeappropriate action

    Corrosion in concentrated

    acid tan#s and lines

    a. 0ow concentration of sulphuric acid

    b. 0ining of #Cl tank!pipe line damaged

    Check silica gel breather in acid

    storage tank and replace silica gelcharge if e%hausted

    Rectify

    (mproper opening andclosing of pneumatically

    operated valves

    a. 1efective solenoid valves

    b. 0eakage in airline from solenoid valve to the

    respective control valve.

    c. Improper contact of micro switch giving falseindication to panel

    d. Fused mimic lamp giving false indication to thepanel

    Check

    Check

    Check

    Check

  • 8/13/2019 Troubleshooting of Demin Plant

    8/8

    (mproper operation of acertain regeneration cycle

    a. 1efective relays in the control circuit Check and replace relays

    ,olid state programme notfunctioning properly

    a. /he controller can be kept in 8hold8 due to thereasons e%plained under operation

    b. Improper operation of the controls for thecontroller

    c. 1efect in the inside of the controller

    Remove conditions which cause 8hold8of controller

    Press test switch 7 check the completecycle

    Check the instruments thoroughly frominside. &eanwhile" operation may becontinued by using bypass toggle

    switches