Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
TORK DIGITAL
UNIVERSAL INPUT - 1 CHANNELMaintained or Momentary ContactsAPPLICATIONSAccepts photocell (TORK Model EPC1 - see bottom right) orany dry maintained contact closure input.• Outdoor lighting - photocell ON/time OFF• HVAC with thermostat input for remote temperature override
MAINTAINED CONTACT - DGU100• Electrically held contactor• Mechanically held coil clearing contactor
MOMENTARY CONTACT - DGUM100• Mechanically held contactor - 2 coil• Pulse latched contactor• Low voltage latching relay
Capable of different schedules each day of the week.ON and OFF SET POINTS
Total # Per Week Minimum Setting32 1 minute
FEATURESHoliday
Daylight SavingLeap YearDisplayManual Override
Clock FormatPower OutageBackup
3 Position SlideSwitch for VariousTypes of Input
1 special schedule can be executed for anynumber of days
Automatic adjustment (can be omitted)Automatic compensationLCDUntil the next regularly scheduled ON orOFF. Automatic operation then resumes.AM/PM (can be set to 24 hour if required)Battery back-up retains schedules - usesstandard 9V conveniently accessible from thefront. Lithium averages 450 hours. Alkalineaverages 175 hours.1 . Photocell input delayed response2. Photocell input quick response3. Dry contact closure
CONTACTTYPE
MaintainedMomentary
MODELDGU100
DGUM100
CLOCK INPUT50/60 HZ120VAC120V AC
DRY CONTACTS(unpowered)
SPOT2-SPDT
Units are available in 240 VAC - add suffix 2, 277 VAC - add suffix 3,24 VAC - add suffix 24, 12 VDC - add suffix 12
WIRING DIAGRAM —————————————————DGU100 TOOK PHOTOCELL
MODEL EPC1OR MAINTAINED
SWITCH
(nottx
REMOTE INPUTFROM MAINTAINED
SWITCH
•-1 h
DGU/DGUM100
LISTEDMeets California
Energy CommissionTitle 24 requirements.
SPECIFICATIONSPower Consumption: 4VA Max.Contact Ratings:
Model DGU100 - see chart on page 48.Model DGUM100 - see chart on page 59.
Timing Accuracy: Line frequency.Operating Temperature: -4 to +122°F (-20° to +50°C)Storage Temperature: -22 to +167°F (-30 to +75°C)Relative Humidity: 0 to 90% R.H.non-condensingEnclosure:See end of controls section for dimensions.Noryrindoor/outdoor (NEMA 3R) is standard. Metal is available.Other mountings: Metal Indoor (suffix Y), Flush, with lock and key(suffix FLG), Bracket mounting - specify mechanism only or mecha-nism with bracket.
SPECIFICATION WRITER'S GUIDEModel DGU1001. Furnish and install TORK Model DGU100 digital time switch with
universal input (TORK's EPC1 photocell or dry contact closure).2. Controller shall be capable of 32 set points.3. Controller shall program in 1 minute resolution.4. Controller shall be capable of a different schedule each day of the
week.
APPLIES TO BOTH MODELS5. Controller shall program in AM/PM or 24 Hour format.6. Display shall be LCD.7. Controller shall have daylight saving or standard time.8. Controller shall have automatic leap year compensation.9. Controller shall have battery backup capability of 275 hours with
Lithium or 100 hours with Alkaline battery.10. Controller shall be capable of manual override ON or OFF to
the next scheduled event.11. Unit shall have an indoor/outdoor Noryl enclosure as standard.
Model DGUM1001. Furnish and install TORK Model DGUM100 digital time switch with
universal input (Tork's EPC1 photocell or dry contact closure) andmomentary output contacts.
2. Controller shall be capable of 32 set points.3. Controller shall program in 1 minute resolution.4. Controller shall be capable of a different schedule each day of the
week.Write 5-11 as above.
EPC1 PHOTOCELL - TORK Model EPC1 photocell is enclosed in atough Lexan® housing for 1/2" conduit mounting and 180 degree swivel. Itis used as a photocell input for models DGU100 and DGUM100. A 1 to100 fc light level adjustment is available at the time switch. Maximum runlength of twisted pair wire: 250' with 22 AWG, 500' with 18 AWG.
TORK 1 Grove St., Mt. Vernon, NY 1055O • Tel: 914-664-3542 • Fax: 914-664-5052 • Internet: http://www.tork.com
TORK ENCLOSURE DIMENSIONS
METAL INDOOR NEMA 1#68229STD. FOR MODELS M-11/16'H11011102110311041101 FM1104FM71007102720072027120
712280018004801180618121830186018602E100 Series,EH10/20
7-15/16"
lf*>,^^ t?^^^
T2-15/16"
JJ_
METAL INDOORNEMA1#63100STD. FOR MODELS7220, (L) 1847AL LC2007222, (L) 1847AZL LDS-A
8001L LDSH-A80078007L8007V81508150U
7200L7202L7120L1847A1848A1849A1847AZ
9-1/4"
T3 3-3/4"
1
AVAILABLEFOR SERIESDZS, DTS,DW, DWZ,DG
METAL INDOORNEMA1#63016-1STD. FOR MODELSTZ220L W302LTZ300L TW220LW300 TW300LW302 T920LW300L T930L
4-3/4'
L
METAL INDOOR/OUTDOORNEMA 3Model 9000A - Suffix O(replaces Model 9000)STD. FOR MODELS
7300, (L) 7302Z7302, (L) 7300ZL7300Z 7302ZL
AVAILABLE FOR MODELS
-5-1/4"-lol
Ccx>
11011102110311041101FM1104FM71007102
7200, (L,Z,ZL)7202, (L,Z,ZL)7120, (L,Z,ZL)7122, (L,ZL)7220, (L)7222, (L)1847A1847AZ
1847AL1847AZL80018004E100 Series8001U80078007L
14-5/8'
1
8007V801180618121830186018602
DW, DWZ, DZS, DTS Series
METAL INDOOR/OUTDOORNEMA3Model 9006 - Suffix OAVAILABLE FOR MODELSW100W200W202W300W302W120W220
W222W220LW222LW300LW302LTW220LTW300L
T920LT930L1847AW1847AWL
METAL INDOOR/OUTDOOR - NEMA 3Model 90131 - Suffix O
DIMENSIONS: 10-1/2" x 7-7/8" x 4-3/4"
AVAILABLE FOR MODELSW400ALW402AL
METAL INDOORNEMA1#70100STD. FOR MODELSW100W200W202W120W220
W222W220LW222L1847 AW1847AWL
METAL INDOORNEMA1STD. FOR MODELSW400A W400ALW402A W402AL
NORYL® INDOOR/OUTDOORNEMA3RModel 9000N -Suffix N
STD. FOR MODELSDG SeriesDZS SeriesDTS SeriesDW Series
AVAILABLE FOR MODELS
7200Z,(L)7202Z,(L)7120Z,(L)7122ZL
DWZ SeriesSMC-3D
11011102110311041101FM1104FM71007102
7202, (L,Z,ZL)7120, (L,Z,ZL)71227122ZL7220, (L)7222, (L)1847A1847AZ
7200, (L,Z,ZL) 1847'AL
1847AZL800180048001U80118061812183018601
8602E100 Series
TORK 1 Grove St., Mt. Vernon, NY 10550 • Tel: 914-664-3542 • Fax: 914-664-5052 • Internet: http://www.tork.com
TORK DIGITAL
MOMENTARY CONTACTS1 CHANNELAPPLICATIONSIdeal for use with:
• Low voltage latching relays• Mechanically held contactors• Magnetically held contactors• Building sweep OFF of low voltage systems• Direct wire to motor starters thus eliminating the need
for any other momentary interface device.
DGM100
Capable of different schedules each day of the week.ON and OFF SET POINTS
Total # Per Week Minimum Setting32 1 minute
2 SPOT momentary contact (2 second) outputs1 for ON, 1 for OFF.
FEATURESHoliday
Daylight SavingLeap YearDisplayManual Override
Clock FormatPower OutageBackup
1 special schedule can be executed for anynumber of days
Automatic adjustment (can be omitted)Automatic compensationLCDUntil the next regularly scheduled ON orOFF. Automatic operation then resumes.AM/PM (can be set to 24 hour if required)Battery back-up retains schedules - usesstandard 9V conveniently accessible from thefront. Lithium averages 450 hours. Alkalineaverages 175 hours.
VJnL/tnii'vva ir
MODEL
DGM 100
trvsnmm i\jiv
CLOCK INPUT50/60 Hz
120 VAC
DRY CONTACTS(unpowered)
2 SPOT
Available in 240 VAC - add suffix 2, 277 VAC - add suffix 3,24 VAC - add suffix 24, 12 VDC - add suffix 12
All models available for panel, bracket, and flush mounting.
WIRING DIAGRAM _______________
ON OFF
I rl I r1H N
-[
N0 ; NC NO c NC
—— HI ————— • PULS
PULSE ON > TO MECHANICALLY-HELD*: PULSE TYPE CONTACTORS
©<§LISTED
Meets CaliforniaEnergy Commission
Title 24 requirements.
SPECIFICATIONSPower Consumption: 4VA Max.Contact Ratings:
UL CSA
Resistive or 120/240VACInductive
Resistive 28VDCPilot Duty 120/240VAC
277VACMotor Load 120VAC
240VAC
NO15A
15A470VA690VA1 HP2 HP
NC10A
10A275VA-
1/4 HP1/2 HP
General 120/240VACPurpose
Resistive 28VDCMotor Load 125VAC
240VACPilot Duty 120/240VAC
277VAC
NO10A
10A1/2 HP1 HP
470VA690VA
NC10A
10A1/4 HP1/2HP275VA
-
Timing Accuracy: Line frequencyOperating Temperature: -4 to +122° F (-20 to +50° C)Storage Temperature: -22 to +167° F (-30 to +75° C)Relative Humidity: 0 to 90% R.H. (non-condensing)Enclosure:See end of controls section for dimensions.Noryl® Indoor/Outdoor (NEMA 3R) is standard. Metal is available.Other mountings: Metal Indoor (suffix Y), Flush, with lock and key(suffix FLG) - Model 9011, Bracket mounting specify mechanism onlyor mechanism with bracket.
SPECIFICATION WRITER'S GUIDE1. Furnish and install TORK Model DGM100 digital time switch with
momentary contact capabilities.2. Controller shall be capable of 32 set points.3. Controller shall program in 1 minute resolution.4. Controller shall be capable of a different schedule each day of the
week.5. Controller shall program in AM/PM or 24 Hour format.6. Display shall be LCD.7. Controller shall have daylight saving or standard time.8. Controller shall have automatic leap year compensation.9. Controller shall have battery backup capability of 450 hours with
Lithium or 175 hours with Alkaline battery.10. Controller shall be capable of manual override ON or OFF to the
next scheduled event.11. Unit shall have an indoor/outdoor Noryl enclosure as standard.
TORK 1 Grove St., Mt. Vernon, NY 1055O • Tel: 914-664-3542 • Fax: 914-664-5052 • Internet: http://www.tork.com
TABLE OF CONTENTSSEE BACK OF CATALOG FOR MODEL NUMBER INDEX
SERIES #PHOTOELECTRIC CONTROLS
Design features.......................................................................................................................................................... 4Product features......................................................................................................................................................... 5
2000 Conduit mounting - fixed position............................................................................................................................... 62020 Conduit mounting - 180° swivel - Pencil..................................................................................................................... 72001 Conduit mounting - 180° swivel................................................................................................................................. 82100 Conduit mounting - zinc housing................................................................................................................................ 93000 Flush mounting.......................................................................................................................................................... 105000S Turn-lock mounting - standard gap lightning arrester................................................................................................ 115000M Turn-lock mounting - MOV lightning arrester............................................................................................................. 122005/7/8 Turn-lock mounting - instant response....................................................................................................................... 135400 6000 watt contactors.................................................................................................................................................. 14
Accessories for turn-lock units................................................................................................................................... 14ELECTROMECHANICAL CONTROLS
Design Features......................................................................................................................................................... 15Product Features....................................................................................................................................................... 16
1100 24 Hour- same ON-OFF times each day.................................................................................................................. 177000 24 Hour-with skip-a-day........................................................................................................................................... 18701A 24 Hour-in-wall......................................................................................................................................................... 19A500 Spring Wound Interval Timers - in-wall...................................................................................................................... 207000Z Astronomic - with day omitting................................................................................................................................... 21TZ Astronomic - with manual by-pass switches.............................................................................................................. 22W 7 Day - different schedule each day.......................................................................................................................... 23TW 7 Day - with manual by-pass switches....................................................................................................................... 24T900 Lighting Control Center - with photoelectric ON-OFF................................................................................................ 251800 Momentary Contact.................................................................................................................................................... 268000 24 Hour Duty Cycle.................................................................................................................................................... 278000 Variable Cycling......................................................................................................................................................... 288150 Oil Well Pumping with delayed start.......................................................................................................................... 294200 Double Dial................................................................................................................................................................ 30WH 24 Hour Water Heater Time Switch........................................................................................................................... 311100 Swimming Pool Controls- 2 circuit............................................................................................................................ 32400 Plug-in Timers............................................................................................................................................................ 33Z Astronomic Dial Kit..................................................................................................................................................... 34
Reserve Power.......................................................................................................................................................... 34Accessories................................................................................................................................................................ 34-35
DIGITAL CONTROLSProduct Features ....................................................................................................................................................... 36-37
SSA In-Wall LCD Digital Interval Timer.............................................................................................................................. 38SSA100R-24 In-Wall LCD Digital Interval Timer- Low voltage and remote ON/OFF ..................................................................... 39SS In-Wall Solid State Interval Timer.............................................................................................................................. 40DIN Din Rail Mounting -1 or 2 channel, 7 Day................................................................................................................. 41ACT Adjustable Cycle Timer.............................................................................................................................................. 42-43E100 Multi-Purpose - 1 channel, 24 Hour/Skip-a-Day/7 Day.............................................................................................. 44-45DWZ100A Multi-Purpose - 1 channel, 7 day .............................................................................................................................. 46DW200A Multi-Purpose - 2 channel, 7 day ............................................................................................................................... 47DG180/DG100 Multi Purpose - 1 channel, 24 Hour/7 Day................................................................................................................. 48DTS100A/200A Multi Purpose - 1 or 2 channel, 365 Day, Single holiday and seasonal scheduling................................................... 49DZS100A/200A Multi Purpose -1 or 2 channel, 365 Day, Single holiday and seasonal scheduling, Astronomic option.................... 50DZS400A/DTS400A Multi-Purpose - 4 channel, 365 Day, Single holiday and seasonal scheduling.......................................................... 51Z400B Multi Purpose - 4 channel, 365 Day, Astronomic option............................................................................................ 52K Multi Purpose - 4, 6, 8 channel, 365 Day, Astronomic option.................................................................................... 53A12/16 12-16 Channel, 365 Day, Digital/Analog Inputs......................................................................................................... 54NM 24 Channel, Monitoring & Control System................................................................................................................. 55DGS180/DGS100 Signal Timers - 1 channel, 24 Hour/7 Day................................................................................................................. 56DTS100A/200A Signal Timers -1 or 2 channel, 365 Day, Single holiday and seasonal scheduling .................................................. 57EH Time-of-Day Water Heater Control............................................................................................................................ 58DGM100 Momentary Contact - 1 channel, 7 Day ..................................................................................................................... 59DZM200A Momentary Contact - 2 channel, 365 Day, Single holiday and seasonal scheduling ................................................ 60DGU/DGUM Universal Input - 1 channel, 7 Day............................................................................................................................. 61LC200 Lighting Controller - Two Zone................................................................................................................................... 62DGLC Digital Lighting Controller........................................................................................................................................... 63LDS Lighting Delay Switch for Lighting Loads................................................................................................................... 64LDSH Lighting Delay Switch for HVAC and Main Building Loads........................................................................................ 65
SPECIAL PURPOSE ACCESSORIESSMC-3D Momentary Contact Adapters.................................................................................................................................... 665400 40 Amp Contactors.................................................................................................................................................... 675810 Pilot Duty Relays........................................................................................................................................................ 67TRP Transformer Relay Powerpacks................................................................................................................................. 68
_.. HPS30 HPS Starter For High Pressure Sodium Lamps......................................................................................................... 69OCCUPANCY SENSORS
PS51D Passive Infrared- in-wall............................................................................................................................................ 70PC10A/20A Passive Infrared - ceiling mount................................................................................................................................. 71PC10AT Passive Infrared with built-in powerpack.................................................................................................................... 72-73PSC15 Passive Infrared and Ultrasonic................................................................................................................................. 74-75SC8/SC15 Ultrasonic................................................................................................................................................................... 76-77SC20 Ultrasonic................................................................................................................................................................... 78-79ELS1 Indoor Ambient Light Sensor..................................................................................................................................... 80-81
COMPETITIVE CROSS REFERENCE - CONTROLS 82 84ENCLOSURE/MECHANISM DIMENSIONS - CONTROLS 85 87