Copyright 2018 by NORAC Systems International Inc. Reorder P/N: 74UT‐TC‐X30‐INST Rev A (Topcon X25, X30, X35 Display Installation Manual) NOTICE: NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information contained in this manual. The technical information in this manual was reviewed at the time of approval for publication.
WWW.NORAC.CA
PRECISION DEFINED
Contents
1 Introduction .......................................................................................................................... 1
2 Technical Specifications ........................................................................................................ 3
3 Installation ............................................................................................................................. 4
4 Cable Schematics ................................................................................................................. 11
WWW.NORAC.CA
PRECISION DEFINED
Page 1 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
1 Introduction
The Topcon X30 Display Option Manual is intended to be used in conjunction with the UC7™ Boom Height Control Installation Manual. This manual provides instructions to interface the UC7 HCM1 Module to the Topcon X25, X30, and X35 displays. For installation of the UC7 Boom Height Control System please refer to the sprayer specific manual provided with the kit.
Please take the time to read this manual completely before attempting to install the system. A thorough understanding of this manual will ensure that you receive the maximum benefit from the system.
Your input can help make us better! If you find issues or have suggestions regarding the parts list or the installation procedure, please don’t hesitate to contact us.
Every effort has been made to ensure the accuracy of the information contained in this manual. All parts supplied are selected to specially fit the sprayer to facilitate a complete installation. However, NORAC cannot guarantee all parts fit as intended due to the variations of the sprayer by the manufacturer.
Please read this manual in its entirety before attempting installation.
The use of dielectric grease is not recommended on any NORAC electrical connections.
WWW.NORAC.CA
PRECISION DEFINED
Page 2 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
1.1. List of Parts (Self‐Propelled Installation)
Item Part Number Name Quantity
C25 50250 SWITCHBOX 1
C26 50140‐11 CABLE SWITCHBOX TEE ‐ 50250 1
C40 1015764‐01 CABLE TOPCON X25, X30 CAB INTERFACE 1
C41 1015765‐01 CABLE TOPCON CM‐40 INTERFACE 1
C42 43220‐0.5 CABLE NETWORK 14 AWG 0.5M 3
C43 43220‐10 CABLE NETWORK 14 AWG 10M 1
E08 50200 CANBUS REPEATER 1
E10 43760 NETWORK COUPLER 3‐WAY 1
E20 43764T NETWORK COUPLER 2‐WAY WITH TERMINATOR 2
M01 UC7‐BC‐MAN‐TECH‐IMP MANUAL UC7 TECHNICAL – IMPERIAL UNITS 1
M04 74UT‐TC‐X30‐INST MANUAL UC7 UT TOPCON X25, X30, X35 DISPLAY KIT 1
1.2. Additional Parts for Pull Type Installation
If installing on a pull type machine, the following parts are needed and must be ordered separately from this kit.
Item Part Number Name Quantity
C44 43220‐03 CABLE NETWORK 14 AWG 3M 1
C45 43210‐15 CABLE NETWORK 18 AWG 15M 1
E12 43764 NETWORK COUPLER 2‐WAY 1
WWW.NORAC.CA
PRECISION DEFINED
Page 3 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
2 Technical Specifications
Table 1: System Specifications
Supply Voltage (rated) 12VDC
Supply Current (rated) 10A
Hydraulic Pressure (maximum) 3300 psi
Baud Rate 250 kbps
Operating Temperature Range 0°C to 80°C
WWW.NORAC.CA
PRECISION DEFINED
Page 4 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
3 Installation
The following steps of the installation assume that the HCM1 module and all required cables are installed.
3.1. CANbus Interface for Topcon Systems without an Apollo
1. Securely mount the control module (E01) in the cab of the sprayer.
2. Connect the ISO CAN LOOP connector on cable C40 to the CAN1/ISOBUS connector on harness AGA4700 (Figure 1 ‐ Green Box).
3. Connect the POWER connector on cable C40 to the SWITCHED POWER connector on harness AGA4700 (Figure 1 ‐ Red Box).
4. Connect the 6‐pin Deutsch plug (NORAC ECU) on cable C40 to the CANbus Repeater (E08). (Figure 1 ‐ Blue Box).
Figure 1: CANbus Interface for Topcon Systems without an Apollo
WWW.NORAC.CA
PRECISION DEFINED
Page 5 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
3.2. CANbus Interface for Topcon Systems with an Apollo
1. Securely mount the control module (E01) near the Topcon Apollo ECU.
2. Connect the SWITCHBOX connector on cable C41 to the SWITCHBOX connector on harness 1009865‐01 or harness 1009864‐01 (Figure 2 ‐ Green Boxes).
3. Connect the POWER connector (receptacle) on cable C41 to the SECTION VALVE POWER connector on harness 1009865‐01 or harness 1009864‐01 (Figure 2 – Red Boxes).
4. Connect the POWER connector (plug) on cable C41 to the POWER connector on harness 1010282‐01 (Figure 2 – Black Boxes).
5. Connect the Deutsch plug on cable C41 to the CANbus Repeater (E08). (Figure 2 ‐ Blue Box).
Figure 2: CANbus Interface for Topcon Systems with an Apollo
WWW.NORAC.CA
PRECISION DEFINED
Page 6 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
3.3. Self‐Propelled Display Cabling Installation
Figure 3: Display Cabling Overview
NOTE: Only parts shown in black are included with this package. Parts shown in blue are included with the UC7™ Boom Height Control System.
1. Connect cable C42 to the 6‐pin display bus connector on the HCM1 (Figure 4).
Figure 4: Display Bus Location
2. Connect cable C42 to cable C43 with a 2‐way coupler with terminator (E20). The 2‐way coupler with terminator is WHITE.
3. Route cable C43 into the cab. Connect to the 3‐way coupler (E10).
Display Bus
WWW.NORAC.CA
PRECISION DEFINED
Page 7 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
4. Connect the power cable (C30) to the 3‐way coupler (E10).
5. Connect the two cables C42 together with a 2‐way coupler with terminator (E20). Connect one end to the 3‐way coupler (E10). Connect the other end to the CANbus Repeater (E08).
6. Connect cable C40 (Installation without an Apollo) or cable C41 (Installation with an Apollo) to the CANbus Repeater (E08).
WWW.NORAC.CA
PRECISION DEFINED
Page 8 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
3.4. Pull Type Display Cabling Installation
If installing on a pull type machine, the parts listed in Section 1.2 are needed and must be ordered separately from this kit. Cable C43 is not used for this type of installation.
Figure 5: Display Cabling Overview
NOTE: Only parts shown in black are included with this package. Parts shown in blue are included with the UC7™ Boom Height Control System.
1. Connect cable C42 to the 6‐pin display bus connector on the HCM1 (Figure 6).
WWW.NORAC.CA
PRECISION DEFINED
Page 9 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
Figure 6: Display Bus Location
2. Connect cable C45 to cable C42 with a 2‐way coupler with terminator (E20). The 2‐way coupler with terminator is WHITE.
3. Route cable C45 to the hitch. Connect cable C45 to cable C44 with a 2‐way coupler (E12). The 2‐way coupler is BLACK. The 2‐way coupler (E12) will provide the hitch disconnect.
4. Route cable C44 into the cab. Connect to the 3‐way coupler (E10).
5. Connect the power cable (C30) to the 3‐way coupler (E10).
6. Connect the two cables C42 together with a 2‐way coupler with terminator (E20). Connect one end to the 3‐way coupler (E10). Connect the other end to the CANbus Repeater (E08).
7. Connect cable C40 (Installation without an Apollo) or cable C41 (Installation with an Apollo) to the CANbus Repeater (E08).
Display Bus
WWW.NORAC.CA
PRECISION DEFINED
Page 10 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
3.5. Switchbox Installation
1. Disconnect cable C20 from the HCM1 module (E01).
2. Insert the 12‐pin tee on cable C26 between the HCM1 module and cable C20.
3. Route the other end of cable 26 to the cab of the sprayer.
4. Install the switchbox (C25) inside the cab. Connect the switchbox to cable C26.
5. If cable C26 is not long enough, a network cable and coupler are available for order from NORAC.
Item Part Number Name
C27 43220‐03 CABLE NETWORK 14 AWG 3M
E12 43764 NETWORK COUPLER 2‐WAY
* Some sprayer types may not use all the switch functions.
Figure 7: Switchbox Installation
NOTE: Only parts shown in black are included with this package. Parts shown in blue are included with the UC7™ Boom Height Control System.
WWW.NORAC.CA
PRECISION DEFINED
Page 11 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
4 Cable Schematics
4.1. Item C25: 50250 – Switchbox
WWW.NORAC.CA
PRECISION DEFINED
Page 12 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
4.2. Item C26: 50140‐11 – Cable Switchbox Tee ‐ 50250
WWW.NORAC.CA
PRECISION DEFINED
Page 13 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
4.3. Item C40: 1015764‐01 – Cable Topcon X25, X30 Cab Interface
WWW.NORAC.CA
PRECISION DEFINED
Page 14 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
4.4. Item C41: 1015765‐01 – Cable Topcon CM‐40 Interface
WWW.NORAC.CA
PRECISION DEFINED
Page 15 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
4.5. Item C42: 43220‐0.5 ‐ Cable Network 14 AWG – 0.5m
WWW.NORAC.CA
PRECISION DEFINED
Page 16 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
4.6. Item C43: 43220‐10 ‐ Cable Network 14 AWG – 10m
WWW.NORAC.CA
PRECISION DEFINED
Page 17 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
4.7. Item C44: 43220‐03 ‐ Cable Network 14 AWG – 3m
WWW.NORAC.CA
PRECISION DEFINED
Page 18 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
4.8. Item C45: 43210‐15 ‐ Cable Network 18 AWG – 15m
WWW.NORAC.CA
PRECISION DEFINED
Page 19 Visit www.solutions.norac.ca for more system installation and troubleshooting info.
Notes
TOPCON Agriculture Canada3702 Kinnear Place
Saskatoon, SK S7P 0A6
TOPCON Agriculture Americas W5527 Hwy 106
Fort Atkinson, WI 53538
TOPCON Precision Agriculture Europe Avenida de la industria, 35, Tres Cantos, España
Spain
Support Phone: 888 979 9509
E‐mail: [email protected] Web: www.norac.ca