WET UNITS …………………………………… 89 Prefabricated Wet Units …………………… 90 Typical Designs …………………………… 91 Details ……………………………………… 92 Installation …………………………………… 95 Standard Equipment and Accessories …… 96 NOTE: NORAC RESERVES THE RIGHT TO MAKE CHANGES TO THE SPECIFICATIONS WITHOUT PRIOR NOTICE ALL DRAWINGS / PHOTOS IN THIS CATALOGUE ARE ILLUSTRATIONS AND GUIDELINES ONLY. SPECIFICATIONS GIVEN IN QUOTATIONS VALID ONLY WET UNITS WET UNITS 89 0575 [email protected] www.shipinteriorsystems.com 503-789-7599 SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Norac USA Wet Modules

Embed Size (px)

DESCRIPTION

Norac Wet Space Modules

Citation preview

Page 1: Norac USA Wet Modules

WEt UNitS …………………………………… 89 Prefabricated Wet Units …………………… 90 Typical Designs …………………………… 91 Details ……………………………………… 92 Installation …………………………………… 95 Standard Equipment and Accessories …… 96

NOtE:NORAC RESERvES tHE RiGHt tO MAKE CHANGES tO tHE SPECiFiCAtiONS WitHOUt PRiOR NOtiCEALL DRAWiNGS / PHOtOS iN tHiS CAtALOGUE ARE iLLUStRAtiONS AND GUiDELiNES ONLY.SPECiFiCAtiONS GivEN iN QUOtAtiONS vALiD ONLY

WET UNITS

W

ET U

NITS

89

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 2: Norac USA Wet Modules

With many years of experience and specialized competence, Norac AS offer fully fitted wet units. The Norac modular wet units are ideal for marine accommodations, from cruise ships to offshore installations.

The Norac wet units, whether standard or custom made, are manufactured according to the strictest rules and regulations and are fabricated from only first class materials.

In our design the emphasis is on using durable solutions to ensuremaximum quality, comfort and well-being of our customers, whether being a ship owner, ship yard or end user.

The units are manufactured with great deal of consideration given to the ease of handling and installation.

Throughout the production process the units are subjected to strict quality control to ensure that all of our supplies conform to our policy of supplying only first class quality.

Bottom may also be made of GRP material.

P r e f a b r i c a t e d We t U n i t s

aluminium constructionPrefabricated modular wet units for all types of marine accommodations also available in light weight, non-corrosive aluminium - B15 class. Weight reduction as much as 20-25%.

WET UNITS

W

ET U

NITS

90

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 3: Norac USA Wet Modules

tYPiCAL StANDARD DEtAiLS Scupper Steel with grate of stainless steel Outlet greywater Plastic pipe (PEH-HT,) 50 mm Fresh water pipe Insulatet cu-pipe prisol 12 mm Connection B.S.P. 1/2’’ Electrical cable 3 x 1.5 mm2

Conduit pipe Flexible Door hinges Stainless steel

ty p i c a l D e s i g n

These units are for guidance only. We deliver units according to customer specification and design.

TYPE 7(1650 X 1180 mm)

B-Module

TYPE 8(1660 X 1250 mm)

B-Module

TYPE 9(1925 X 1125 mm)

B-Module

Wet units can, upon request, be delivered in “knock down” execution.A = Toilet module B = Shower module C = Bath module

TYPE 4(1200 X 2000 mm)

B-Module

TYPE 5(1500 X 1600 mm)

B-Module

TYPE 2(1420 X 1720 mm)

B-Module

TYPE 6(1600 X 1085 mm)

A-Module

TYPE 1(1120 X 1240 mm)

A-Module

TYPE 3(1720 X 2020 mm)

C-Module

WET UNITS

W

ET U

NITS

91

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 4: Norac USA Wet Modules

D e t a i l s20

Bot

tom

fram

e 20

0 m

mC

lear

ope

ning

180

0 m

mTo

p fra

me

25

Air

gap

20 m

m

Doo

r han

dle

heig

ht =

105

0 m

m fr

om s

teel

dec

k

Steel deckAdjustable screw M20 x 60 mm

20 mm insulation glued on panel

Tiles

Threshold cover stainless steel

20 mm insulation glued on top panel

75

Ceiling in wet units

Silicon

Door in single wall

Cle

ar o

peni

ng 1

800

mm

Top

fram

e25

20 m

m A

ir ga

p

Doo

r han

dle

heig

ht =

105

0 m

m fr

om s

teel

dec

k

Steel deck Adjustable screw M20 x 60 mm

20 mm insulation glued on panel

Tiles

Threshold cover stainless steel

20 mm insulation glued on top panel

50

Silicon joint

Door in sandwich wall

50

35 35600

2020 630

Door Leaf

Wet Unitwall panel

Outside wet unit

75 2525

25

45 45

30

3 plastic nob

External wall Outside wet unit

Inside wet unitClear opening 600 mm

3 pcs. drilled hole each side for fixing external wall to the doorframeU-profile 20x25x15x0.7 mm

Norac wet units can be supplied with the cabin side having a finished surface as shown above.

As standard the external linings slide into the door frames.

Inside wet unit

Details outwards opened door - Wet Unit

Right opened door - DIN R

Silicon joint

20

Bot

tom

fram

e 20

0 m

m

WET UNITS

W

ET U

NITS

92

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 5: Norac USA Wet Modules

D e t a i l sNorac wet units can be delivered with different draining systems according to our customer's specification.

Norac wet units are delivered with walls and ceilings manufactured in a sandwich construction with no open/visible insulation.

B-15 class in both steel and aluminium constructions.

Floor pan with step

Shower area

Screed/heating cables

Ceiling panel - finish inside wet units

Double wall - finish both sides (PVC)

Varia

ble

50

Single wall - finish inside wet units only

Solution for heating cable and/or step

The floor pan is fully tested water tight, blasted and primed before application of finish

Ceiling panel - finish inside wet units

Details of optional heat-ing cables of floor

Double wall - finish both sides (PVC)

Varia

ble

Floor pan with slope Single wall - finish inside wet units only

Standard solution for tiled floor

Heating cableScreed Rounded

edge on tile

Silicone joint

Glu

ed jo

int b

otto

m p

rofil

e / W

allp

anel

WET UNITS

W

ET U

NITS

93

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 6: Norac USA Wet Modules

D e t a i l sStandard Norac Responsibility:

Standard Yard supply:

interface responsibility

Green = Yard supplyOrange = Norac supply

If gravity toilet, normally Norac supply

Grey water connection 50 mm

Penetration frame

EL-Junction box (The connection can also be done in the junctionbox beside door)

Shut down value connection male1/2”

If vacuum toilet, normally yard supply

Grey water (shower and sink)

Electrical cable

Ventilation duct

Black water (toilet)

Cold and hot water pipe

WET UNITS

W

ET U

NITS

94

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 7: Norac USA Wet Modules

The standard units are delivered each with four square tubes for easy lifting and locating on board. A specially designed lifting frame is used for hoisting by crane.

After lifting on board, transportation wheels are fitted into the tubes. The units are then jacked up and transported to their final position.

All units are delivered with one adjustable leg at eachcorner to allow for levelling.

Norac wet units are so complete when delivered that after fixing them to the deck you only need connect the water, drainage and electricity to use them.

Norac wet units have been successfully installed on numerous vessels throughout the world, whether they are on a luxury cruise liner, commercial vessel or offshore platform.

i n s t a l l a t i o n

Norac wet units are easy to handle and locate on board

Adjusting height of bathroom unit – option1 pc placed on the corner of bathroom unit (normally 5 pcs on each unit)

Steel plate 100 x 100 x 10 mm

Tube 30 x 30 x 2 L= 300 for lifting (4 corners)

M20 x 50 mm adjusting bolt 5 off per unit

After adjusting of wet unit weld the bolt to the steel deck.

WET UNITS

W

ET U

NITS

95

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 8: Norac USA Wet Modules

S t a n d a r d E q u i p m e n t a n d A c c e s s o r i e s

Wash-basin, white china Dim.: 500 x 355Dim.: 600 x 450

Operator

WC Shower set

Shower mixer Mixing tap

Cistern (Especially made for ships)

Shower mixer

Folding seat

WET UNITS

W

ET U

NITS

96

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 9: Norac USA Wet Modules

S t a n d a r d E q u i p m e n t a n d A c c e s s o r i e s

Soap holder Hook

Tumbler holder + glass Tumbler holder + glass

Spare paper holder Toilet paper holder

Double hook

Ashtray

Toilet brush and holder

WET UNITS

W

ET U

NITS

97

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 10: Norac USA Wet Modules

S t a n d a r d E q u i p m e n t a n d A c c e s s o r i e s

Toilet cabinet Grab rail

Light fitting, 1x18W with razor socket 110/220 V IP44

Shower mixer.

Wash-basin

Shower set.

WCMixing tapPaffoni Saturno ST071 CR6

Towel rail (All in length 30-45-60 cm)

WET UNITS

W

ET U

NITS

98

0575

[email protected] www.shipinteriorsystems.com 503-789-7599