404
IBM Netcool Performance Manager 1.3 Wireline Component (Netcool/Proviso 5.2) Tivoli Document Revsion R2E1 Error Messages Guide

Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

IBMNetcool Performance Manager 1.3Tivoli

Wireline Component (Netcool/Proviso 5.2)

Document Revsion R2E1

Error Messages Guide

Page 2: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Note

Before using this information and the product it supports, read the information in “Notices” on page -379.

Copyright IBM Corp. 1997, 2010

US Government Users Restricted Rights - Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

Page 3: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Contents

Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv

Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv

Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv

The Netcool/Proviso Product Suite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv

Netcool/Proviso Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi

Chapter 1:Netcool/Proviso Log Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

The Proviso Log File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1The Log File Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

10001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

10002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

10003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

10004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

10005. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

10006. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

10007. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

10008. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

10009. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

10010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

10011. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

10012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

10013. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

10014. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

10015. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

10016. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

10017. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

10019. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

10020. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

10021. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

10022. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

10023. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

10024. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Netcool/Proviso Error Messages Guide, Version 5.2 iii

Page 4: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Contents

10025 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

10026 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

10027 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

10028 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

10029 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

10030 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

10031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

10032 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

10033 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

10034 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

10035 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

10036 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

10037 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

10038 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

10039 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

10040 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

10041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

10042 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

10043 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

10044 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

10045 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

10046 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

10047 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

10048 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

10049 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

10050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

10051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

10052 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

10053 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

10054 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

10055 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

10056 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

10057 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

10058 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

10059 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

10060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

iv Netcool/Proviso Error Messages Guide, Version 5.2

Page 5: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Contents

10061. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

10062. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

10063. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

10064. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

10065. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

10066. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

10100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

10101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

10102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

10103. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

10104. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

10105. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

10106. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

10107. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

10108. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

10109. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

10110. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

10111. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

10112. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

10113. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

10114. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

10115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

10117. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

10118. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

10119. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

10120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86

10121. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

10122. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88

10123. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89

10124. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

10125. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

10126. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

10127. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

10128. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

10129. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95

10130. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96

Netcool/Proviso Error Messages Guide, Version 5.2 v

Page 6: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Contents

10131 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

10132 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98

10133 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

10134 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100

10135 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

10136 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

10137 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103

10138 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104

10139 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

10140 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

10141 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

10142 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108

10143 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

10144 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110

10145 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111

10146 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

10147 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113

10148 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

10149 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115

10150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116

10151 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117

10152 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118

10153 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119

10154 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120

10155 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

10156 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122

10157 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123

10160 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124

10161 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125

10162 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126

10163 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127

10164 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128

10165 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129

10166 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130

10167 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131

10168 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132

vi Netcool/Proviso Error Messages Guide, Version 5.2

Page 7: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Contents

10169. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133

10170. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

10171. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135

10172. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136

10173. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137

10174. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

10175. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139

10176. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140

10177. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141

10178. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142

10179. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143

10180. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144

10181. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145

10182. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146

10183. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147

10184. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148

10185. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149

10186. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150

10187. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151

10188. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152

10189. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153

10200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154

10201. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155

10204. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156

10205. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157

10206. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158

10207. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159

10208. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160

10209. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161

10210. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162

10211. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163

10212. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164

10213. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165

10214. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166

10216. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167

10217. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168

Netcool/Proviso Error Messages Guide, Version 5.2 vii

Page 8: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Contents

10218 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169

10219 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170

10220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171

10221 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172

10301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173

10302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174

10304 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175

10305 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176

10306 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177

10307 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178

10308 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179

10309 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180

10310 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181

10311 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182

10312 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183

10313 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184

10314 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185

10315 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186

10316 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187

10317 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188

10318 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189

10400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190

10401 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191

10402 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192

10404 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193

10405 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194

10406 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195

10407 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196

10408 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197

10409 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198

10410 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199

10411 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200

10412 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201

10413 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202

10414 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203

10415 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204

viii Netcool/Proviso Error Messages Guide, Version 5.2

Page 9: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Contents

10416. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205

10417. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206

10418. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207

10419. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208

10420. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209

10421. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210

10422. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211

10423. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212

10424. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213

10425. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214

10426. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215

10427. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216

10428. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217

10429. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218

10430. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219

10431. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220

10432. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221

10433. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222

10434. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223

10435. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224

10437. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225

10439. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226

10440. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227

10441. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228

10442. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229

10443. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230

10444. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231

10445. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232

10446. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233

10447. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234

10448. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235

10501. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236

10502. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237

10503. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238

10504. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239

10505. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240

Netcool/Proviso Error Messages Guide, Version 5.2 ix

Page 10: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Contents

10506 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241

10507 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242

10508 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243

10509 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244

10510 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245

10519 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246

10520 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247

10521 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248

10549 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249

10559 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250

10579 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251

10590 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252

10591 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253

10592 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254

10593 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255

10594 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256

10600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257

10601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258

10602 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259

10603 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260

10604 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261

10605 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262

10606 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263

10607 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264

10608 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265

10609 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266

10610 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267

10611 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268

10612 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269

10613 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270

10614 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271

10615 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272

10616 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273

10617 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274

10618 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275

10619 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276

x Netcool/Proviso Error Messages Guide, Version 5.2

Page 11: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Contents

10620. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277

10621. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278

10622. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279

10623. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280

10624. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281

10625. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282

10626. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283

10628. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284

10629. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285

10630. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286

10631. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287

10632. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288

10633. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289

10634. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290

10636. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291

10638. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292

10639. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293

10640. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294

10641. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295

10642. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296

10643. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297

10650. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298

10701. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299

10702. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300

10703. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301

10704. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302

10705. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303

10706. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304

10707. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305

10708. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306

10709. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307

10710. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308

10711. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309

10712. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310

10751. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311

10752. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312

Netcool/Proviso Error Messages Guide, Version 5.2 xi

Page 12: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Contents

10753 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313

10754 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314

10755 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315

10756 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316

10757 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317

10758 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318

10759 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319

10760 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320

10800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321

10801 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322

10802 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323

10803 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324

10804 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325

10805 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326

10806 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327

10807 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328

10808 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329

10809 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330

10810 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331

10811 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332

10850 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333

10851 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334

10852 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335

10853 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336

10854 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337

10855 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338

10856 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339

10857 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340

10858 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341

10859 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342

10860 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343

10861 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344

10862 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345

10863 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346

10864 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347

10865 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348

xii Netcool/Proviso Error Messages Guide, Version 5.2

Page 13: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Contents

10866. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349

10900. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350

10901. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351

10902. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352

10903. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353

10904. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354

10905. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355

11016. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 356

11017. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357

11018. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 358

11019. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359

12347. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360

12349. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361

12350. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362

12351. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363

12352. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364

12356. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365

12357. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366

12358. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 367

12360. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368

39001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369

39002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370

39201. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371

39205. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372

39206. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373

39207. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374

39208. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375

39209. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377

Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 379

Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 380Tcl 8.3.3, Combat/TCL 0.7.3, Combat/TCL 0.7.5, TclX 8.3, TK 8.3.3 . . . . . . . . . . . . . . . . . . . 381SCOTTY Stack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 381BLT 2.4u . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383CMU-SNMP 1.14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383Scotty 2.8, incrTCL 3.0, [incr TCL] 3.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383

Netcool/Proviso Error Messages Guide, Version 5.2 xiii

Page 14: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Contents

UCD SNMP 4.2.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384JDOM 1.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385Regex 1.1a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385

xiv Netcool/Proviso Error Messages Guide, Version 5.2

Page 15: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Preface

IBM® Tivoli® Netcool® Performance Manager 1.3 is a bundled product consisting of a wireline component (formerly Tivoli Netcool/Proviso) and a wireless component (formerly Tivoli Netcool Performance Manager for Wireless).

The purpose of this guide is to help you manage and troubleshoot problems with Netcool/Proviso DataChannel and DataLoad. The guide should be used in conjunction with the Netcool/Proviso SNMP Inventory Management and Troubleshooting Guide.

Audience

The audience for this guide is the Netcool/Proviso administrator who is trying to remedy a situation that produced an error message.

Organization

This guide is organized as follows:

• This chapter – General information about the audience, guide, conventions, documentation, and technical support.

• Chapter 1, Netcool/Proviso Log Messages on page 1 – Lists in ordinal, reference format error messages produced by DataChannel and DataLoad. Whenever possible, explanations are offered, as well as remedial actions.

The Netcool/Proviso Product Suite

Netcool/Proviso is made up of the following components:

• Netcool/Proviso DataMart is a set of management, configuration and troubleshooting GUIs that the Netcool/Proviso System Administrator uses to define policies and configuration, as well as verify and troubleshoot operations.

• Netcool/Proviso DataLoad provides flexible, distributed data collection and data import of SNMP and non-SNMP data to a centralized database.

• Netcool/Proviso DataChannel aggregates the data collected through Netcool/Proviso DataLoad for use by the Netcool/Proviso DataView reporting functions. It also processes on-line calculations and detects real-time threshold violations.

• Netcool/Proviso DataView is a reliable application server for on-demand, web-based network reports.

• Netcool/Proviso Technology Packs extend the Netcool/Proviso system with service-ready reports for network operations, business development, and customer viewing.

The following figure shows the different Netcool/Proviso modules.

Netcool/Proviso Error Messages Guide, Version 5.2 xv

Page 16: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Preface

Figure 1: Netcool/Proviso Modules

DataLoadcollects network data.

DataChannelcomputesaggregationsand stores datain DataMart.

DataMartprovides datamanagement

DataViewproduces andmanages reports.

and applications.

Netcool/Proviso Documentation

Netcool/Proviso documentation consists of the following:

• release notes

• configuration recommendations

• user guides

• technical notes

• online help

The documentation is available for viewing and downloading on the infocenter at:

http://publib.boulder.ibm.com/infocenter/tivihelp/v8r1/topic/com.ibm.netcool_pm.doc/welcome_tnpm.htm

xvi Netcool/Proviso Error Messages Guide, Version 5.2

Page 17: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

Overview

This chapter lists, in ordinal, reference format, the error messages collected in the Netcool/Proviso log, and – whenever possible – provides explanations and suggests remedial actions.

Note: Currently, only DataChannel and DataLoad write to the Netcool/Proviso log. Log files for other components can be found in $PVMHOME/log (/opt/datamart/log, by default) and SILVERSTREAM_HOME/log (/opt/silverstream/log, by default).

The Proviso Log File

The Netcool/Proviso log (proviso.log) is located in the DataChannelInstallROOT/log directory (/opt/datachannel/log by default) and should be monitored on a regular basis.

You can write a program to do this (recommended) or you can check the log by hand, using the grep command.

For example, the following command checks the log for a fatal loader error:

grep CMGR proviso.log | grep –w F

982348945 2001.02.16-18.42.25 CMGR F ERROR There was a problem loading the domain database

The Log File Format

Entries in the Netcool/Proviso log file have the following format:

<formatted date> <facility> <severity> [<msg code>] <message> <information>

• <formatted date> is a formatted date string YYYY.MM.DD-hh.mm.ss

• <facility> indicates the program that made the log file entry (for example, CMGR for Channel Manager)

• <severity> can be one of the following:

– I – informational

– W – Warning

– F – Failure

– 1 – Debug level 1

– 2 – Debug level 2

– 3 – Debug level 3

• <msg code> is a registered msg code for fatal and warning log messages

• <message> indicates the basic type of the message

• <information> is an additional text message

The following reference pages explain each error message in detail.

Netcool/Proviso Error Messages Guide, Version 5.2 1

Page 18: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10001

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

Configuration of <service_name> failed: <detailed_error>

TAG

CORBASVCERR

COMMENT

Configuration of specified Corba service (that is, name service, event service) failed at component startup.

CAUSE

Possible installation problem.

ACTION

Contact IBM Technical Support.

2 Netcool/Proviso Error Messages Guide, Version 5.2

Page 19: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10002

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

Message text (depends on the failure)

TAG

STARTUPERR

COMMENT

Component startup failure. Incorrect configuration or missing components.

CAUSE

Configuration settings in Netcool/Proviso configuration file conf/dc.config is not correct.

ACTION

Verify Netcool/Proviso configuration file.

Netcool/Proviso Error Messages Guide, Version 5.2 3

Page 20: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10003

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

No collectors defined in registry table

TAG

NO_COLLECTORS

COMMENT

Database configuration for collectors/channel is not specified properly.

CAUSE

Installation problem.

ACTION

Check installation for this (sub)channel.

4 Netcool/Proviso Error Messages Guide, Version 5.2

Page 21: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10004

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

Shutting down the image with error: <detailed_error>

TAG

ERROR

COMMENT

Unhandled fatal runtime exception — application produces walkback file and shuts down.

CAUSE

Database or file system failure (no space on device, not enough privileges).

ACTION

If the condition causing failure is transient, the application will restart automatically and in many cases will continue. If the problem persists, contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 5

Page 22: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10005

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Timed Out during TS query for mid: <mid> rid: <rid> start: <start> end: <end>

TAG

REMOTE_TUPLE_QUERY

COMMENT

CME experienced a timeout during a tuple storage query.

CAUSE

Too much data to retrieve in time or another component is unreachable or not running.

ACTION

Check connectivity and make sure other components are running.

6 Netcool/Proviso Error Messages Guide, Version 5.2

Page 23: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10006

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

Error: this should not happen. PBL has paused because it tried to create a label. FRMI should force the user to assign labels so that PBL never has to create a label. To restart PBL remove {stop file}

TAG

PBLSTOP

COMMENT

PBL is paused pending manual intervention. contact IBM Technical support to fix FRMI bug and have formula -> label data manually corrected.

CAUSE

FRMI bug.

ACTION

Manually fix the problem and remove STOP file in the PBL root directory. If the problem persists, contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 7

Page 24: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10007

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Too many failed acquisition attempts, giving up on remainder of input acquisitions

TAG

ACQUISITION_ERROR_LIMIT

COMMENT

While trying to acquire input files, multiple errors occurred and no further attempts will be made to acquire files on this poll. Acquisition will resume on the next poll.

CAUSE

Multiple errors can be the cause, including network issues affecting connectivity, an FTP server not running or a misconfigured FTP server.

ACTION

Look for messages in the logs that indicate failures to acquire specific files and troubleshoot the reasons for the failures. Try and acquire the problematic files manually using FTP or SFTP and check that the expected files and directories exist and can be accessed.

8 Netcool/Proviso Error Messages Guide, Version 5.2

Page 25: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10008

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

Waiting For Data For Schemas: <1s>

TAG

INPUTS_MISSING

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 9

Page 26: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10009

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Stopping plan builder because plan save to db failed

TAG

PLAN_SAVE_ERROR

COMMENT

The plan builder has been stopped because saving the plan to the database has failed.

CAUSE

Could be duplicate rows, database error, Smalltalk exception, or something else.

ACTION

Review the proviso.log file for any previously reported warning messages from the plan builder.

10 Netcool/Proviso Error Messages Guide, Version 5.2

Page 27: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10010

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

There are multiple specific formulas: <specificFormulas> for this generic formula: <timeSeries>. These specific formulas are for the same resource and reside in different labels <specificLabels>

TAG

MULTIPLE_SPECIFIC_TO_GENERIC

COMMENT

You cannot have multiple specific formulas for the same resource doing a specific to generic conversion where the specific timeseries are in different labels because the plan builder does not know which label to assign to the generic timeseries. The plan builder with pick any of the specific labels to assign to the generic timeseries.

CAUSE

There could be a problem with formula definitions where one or more specific formulas refer the wrong generic id.

ACTION

Review all specific formulas for this generic formula and review all specific formulas for this resource.

Netcool/Proviso Error Messages Guide, Version 5.2 11

Page 28: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10011

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Skipped building input for <timeseries> because sub-element is inactive. This could happen if the subelement is inactive, or it has no element or elements collector is wrong

TAG

MISSING_INPUT_INACTIVE

COMMENT

Unable to build input becuase sub-element is inactive, or it has no element or elements collector is wrong.

CAUSE

Subelement is inactive, or it has no element or elements collector is wrong.

ACTION

Check to see if sub-element is active and has an element and the collector is right.

12 Netcool/Proviso Error Messages Guide, Version 5.2

Page 29: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10012

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

There are too many specific formula requests for <timeseries> <requests>. This is a misconfiguration that can cause loss of data and excessive plan churn

TAG

TOO_MANY_SPECIFIC_FORMULA_REQUESTS

COMMENT

There should only be one specific formula request for a timeseries.

CAUSE

More than one request for different specific formulas that have the same generic formula for the same resource.

ACTION

Figure out why there are more than one specific timeseries for the same resource and formula. Check requests.

Netcool/Proviso Error Messages Guide, Version 5.2 13

Page 30: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10013

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

N/A

TAG

RESTART_NEEDED

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

14 Netcool/Proviso Error Messages Guide, Version 5.2

Page 31: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10014

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

SEND_ERROR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 15

Page 32: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10015

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Not acquiring data because do directory at max hours

TAG

NOT_ACQUIRING_DATA

COMMENT

Indicates that the UBA has stopped acquiring data because the "do" directory has too many hours worth of data queued up to be processed.

CAUSE

There is a large amount of input data to be processed. It is possible that Input data accumulated because the UBA process was stopped.

ACTION

It may not be necessary to do anything. As the UBA processes data and catches up, this situation will correct itself. The amount of data allowed in the "do" directory is controlled by the FC_MAX_DO_HOURS configuration setting.

16 Netcool/Proviso Error Messages Guide, Version 5.2

Page 33: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10016

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Acquired files in <1p> seconds

TAG

PERF_ACQUIRE_ALL

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 17

Page 34: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10017

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

<1s>: Flush tuples for period for <2s>. Sorted <3p> tuples in <4s> seconds; <5p> out of period tuples

TAG

PERF_STREAM_SORT

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

18 Netcool/Proviso Error Messages Guide, Version 5.2

Page 35: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10019

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

Found <1p> obsolete input descriptors among total of <2p> in <3s> seconds

TAG

PERF_SCAVENGE_OLD_DESCRIPTORS

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 19

Page 36: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10020

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

Acquired <1p> files in <2p> seconds

TAG

PERF_ACQUIRE_ALL

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

20 Netcool/Proviso Error Messages Guide, Version 5.2

Page 37: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10021

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

<5s>: processed <1p> records in <2p> sec (<3p> records/min), rejected <4p> records

TAG

PERF_INPUT_PROCESSING

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 21

Page 38: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10022

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

<1s>: Close period condition detected for period <2s> because <3s>

TAG

STREAM_SORT_CLOSE_PERIOD

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

22 Netcool/Proviso Error Messages Guide, Version 5.2

Page 39: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10023

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Skip processing <file name> -- no collector number found for file

TAG

DONT_PROCESS

COMMENT

The given input file is not being processed because a collector number could not be determined.

CAUSE

A bad file or badly named file was found in the input location.

ACTION

Double check that the input filename and contents are not malformed.

Netcool/Proviso Error Messages Guide, Version 5.2 23

Page 40: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10024

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

N/A

TAG

FLUSH_FILES

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

24 Netcool/Proviso Error Messages Guide, Version 5.2

Page 41: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10025

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

N/A

TAG

DELETING_STATE_FILE

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 25

Page 42: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10026

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

N/A

TAG

DELETING_STATE_FILE

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

26 Netcool/Proviso Error Messages Guide, Version 5.2

Page 43: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10027

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

N/A

TAG

FLUSH_FILES

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 27

Page 44: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10028

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

N/A

TAG

DONT_PROCESS

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

28 Netcool/Proviso Error Messages Guide, Version 5.2

Page 45: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10029

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

N/A

TAG

CURRENT_PERIOD

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 29

Page 46: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10030

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

N/A

TAG

END_OF_PERIOD

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

30 Netcool/Proviso Error Messages Guide, Version 5.2

Page 47: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10031

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

<1s>: Flush tuples for period for <2s>. Sorted <3p> tuples in <4s> seconds; <5p> out of period tuples

TAG

PERF_STREAM_SORT

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 31

Page 48: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10032

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

Found <1p> obsolete input descriptors among total of <2p> in <3s> seconds

TAG

PERF_SCAVENGE_OLD_DESCRIPTORS

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

32 Netcool/Proviso Error Messages Guide, Version 5.2

Page 49: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10033

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to acquire <schema name> input: <file name> reason: <error description>

TAG

ACQUISITION_FAILED

COMMENT

The UBA failed to acquire the indicated file.

CAUSE

An communications error or a misconfiguration of the file, ftp or sftp server.

ACTION

Check the connectivty between the UBA and the file, ftp or sftp server. Connect to the file, ftp or sftp server by hand from the same host and user id as the UBA and make sure the directory and file indicated in the URI exists.

Netcool/Proviso Error Messages Guide, Version 5.2 33

Page 50: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10034

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Timezone database failed to load: <reason>

TAG

TIME_ZONE_DB_LOAD_FAILED

COMMENT

The timezone database failed to load from the ZoneInformational(TZ) DB on the host.

CAUSE

A missing or invalide ZoneInformational(TZ) database.

ACTION

Double check the installation of the ZoneInformational(TZ) database on the host where the problem is occurring.

34 Netcool/Proviso Error Messages Guide, Version 5.2

Page 51: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10035

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Invalid input PvUrl: <pvUrl> for component named: <componentName>

TAG

INVALID_INPUT_COMPONENT

COMMENT

An upstream PvUrl was registered with missing information.

CAUSE

A configuration issue where the PvUrl that got registered was invalid (missing parts it should have).

ACTION

Check the upstream component’s AMGR settings for disk usage server DUS.

Netcool/Proviso Error Messages Guide, Version 5.2 35

Page 52: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10036

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Missing input PvUrl for component named: <aCME>

TAG

MISSING_INPUT_COMPONENT

COMMENT

This message is an indication of a misconfiguration or that an upstream component (CME) was not running yet so it had not registered itself yet, or the upstream CME was failing to register itself because CNS is having problems.

CAUSE

A misconfiguration, CNS is unavailable, or a temporary condition when a CME has not registered with CNS (maybe it has not been started yet).

ACTION

1. Check that CME is properly configured in the system. 2. Check CME is running. 3. Check CNS is running.

36 Netcool/Proviso Error Messages Guide, Version 5.2

Page 53: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10037

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Call to getDurationsForIntervals() expects an array as the first argument

TAG

INVALID_ARGUMENT

COMMENT

The call to getDurationsForIntervals() was invoked with something other than an array for the first argument.

CAUSE

The call to getDurationsForIntervals() was invoked with something other than an array for the first argument.

ACTION

Update ecmascript code.

Netcool/Proviso Error Messages Guide, Version 5.2 37

Page 54: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10038

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Call to getAccumulatedDurationForIntervals() expects an array as the first argument

TAG

INVALID_ARGUMENT

COMMENT

The call to getAccumulatedDurationForIntervals() was invoked with something other than an array for the first argument.

CAUSE

The call to getAccumulatedDurationForIntervals() was invoked with something other than an array for the first argument.

ACTION

Update ecmascript code.

38 Netcool/Proviso Error Messages Guide, Version 5.2

Page 55: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10039

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Needs to be in JMS_FILTER: <1s>

TAG

REQUIRED_EVENT_MISSING_IN_FILTER

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 39

Page 56: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10040

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Does not exist or is not a file: <1s>

TAG

JAR_PATH_DOES_NOT_EXIST

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

40 Netcool/Proviso Error Messages Guide, Version 5.2

Page 57: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10041

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Does not exist or is not a file: <1s>

TAG

JAVA_PATH_DOES_NOT_EXIST

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 41

Page 58: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10042

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Call to getAccumulatedDurationForTuples() expects an array as the first argument

TAG

INVALID_ARGUMENT

COMMENT

The call to getAccumulatedDurationForTuples() was invoked with something other than an array for the first argument.

CAUSE

The call to getAccumulatedDurationForTuples() was invoked with something other than an array for the first argument.

ACTION

Update ecmascript code.

42 Netcool/Proviso Error Messages Guide, Version 5.2

Page 59: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10043

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Call to getAccumulatedDurationForTuples() expects a positive integer as the second argument. Invalid argment: <periodStart>

TAG

INVALID_ARGUMENT

COMMENT

The call to getAccumulatedDurationForTuples() was invoked with something other than an integer for the second argument.

CAUSE

The call to getAccumulatedDurationForTuples() was invoked with something other than an integer for the second argument.

ACTION

Update ecmascript code.

Netcool/Proviso Error Messages Guide, Version 5.2 43

Page 60: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10044

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Call to getAccumulatedDurationForTuples() expects a positive integer as the third argument. Invalid argment: <periodEnd>

TAG

INVALID_ARGUMENT

COMMENT

The call to getAccumulatedDurationForTuples() was invoked with something other than an integer for the third argument.

CAUSE

The call to getAccumulatedDurationForTuples() was invoked with something other than an integer for the third argument.

ACTION

Update ecmascript code.

44 Netcool/Proviso Error Messages Guide, Version 5.2

Page 61: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10045

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Call to getIntervalsForTuples() expects an array as the first argument

TAG

INVALID_ARGUMENT

COMMENT

The call to getIntervalsForTuples() was invoked with something other than an array for the first argument.

CAUSE

The call to getIntervalsForTuples() was invoked with something other than an array for the first argument.

ACTION

Update ecmascript code.

Netcool/Proviso Error Messages Guide, Version 5.2 45

Page 62: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10046

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Call to getIntervalsForTuples() expects a positive integer as the second argument. Invalid argment: <periodStart>

TAG

INVALID_ARGUMENT

COMMENT

The call to getIntervalsForTuples() was invoked with something other than an integer for the second argument.

CAUSE

The call to getIntervalsForTuples() was invoked with something other than an integer for the second argument.

ACTION

Update ecmascript code.

46 Netcool/Proviso Error Messages Guide, Version 5.2

Page 63: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10047

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Call to getIntervalsForTuples() expects a positive integer as the thjrd argument. Invalid argment: <periodEnd>

TAG

INVALID_ARGUMENT

COMMENT

The call to getIntervalsForTuples() was invoked with something other than an integer for the third argument.

CAUSE

The call to getIntervalsForTuples() was invoked with something other than an integer for the third argument.

ACTION

Update ecmascript code.

Netcool/Proviso Error Messages Guide, Version 5.2 47

Page 64: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10048

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

<count> calculcation errors occurred this hour

TAG

CALC_ERRORS

COMMENT

Lists number of calculation errors for a metric in an hour.

CAUSE

Defective formula code or missing inputs.

ACTION

Review the formula code for potential defects.

48 Netcool/Proviso Error Messages Guide, Version 5.2

Page 65: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10049

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Discarded out of sequence <tuples or heartbeat> (into: "<node name>"; timestamp: <timestamp>)

TAG

TUPLE_INJECT_DISCARD

COMMENT

Tuples or data were produced that were out of sequence.

CAUSE

The state for an FTE or CME component was partially deleted.

ACTION

Verify that the system resumes processing normally and check for any lost data.

Netcool/Proviso Error Messages Guide, Version 5.2 49

Page 66: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10050

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

<1s>

TAG

SAM_EXPORT_STATUS

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

50 Netcool/Proviso Error Messages Guide, Version 5.2

Page 67: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10051

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error processing an external request

TAG

DST_EXCEPTION

COMMENT

This message is an indication of either a communications problem, or a failure to process a request coming from another process.

CAUSE

Another process has issued a request that was failed to be successfully processed. This could arise due to a protocol or version mismatch, a bug in processing the request, or a temporary communications interruption.

ACTION

If the issue does not resolve itself, check for physical connectivity between the processes involved in the request.

Netcool/Proviso Error Messages Guide, Version 5.2 51

Page 68: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10052

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Record types don’t match for TS <1p>, Existing record: <2p>, incoming record <3p>

TAG

OP_STATE_DIFF_REC_TYPE

COMMENT

There is a mismatch between existing and new recomputed values during the operator state upgrade.

CAUSE

Technical error or corrupted state.

ACTION

Contact IBM Technical Support.

52 Netcool/Proviso Error Messages Guide, Version 5.2

Page 69: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10053

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Recomp wrapper should have original: TS <1p> record: <2p>, incoming wrapper: <3p>

TAG

OP_STATE_RCM_WRAPPER_SHOULD_HAVE_ORIGINAL

COMMENT

There is a mismatch between existing and new recomputed values during the operator state upgrade.

CAUSE

Technical error or corrupted state.

ACTION

Contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 53

Page 70: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10054

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Values don’t match for TS <1p>, Existing record: <2p>, incoming record: <3p>

TAG

OP_STATE_DIFF_VALUE

COMMENT

There is a mismatch between existing and new recomputed values during the operator state upgrade.

CAUSE

Technical error or corrupted state.

ACTION

Contact IBM Technical Support.

54 Netcool/Proviso Error Messages Guide, Version 5.2

Page 71: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10055

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

The host address is the loopback interface, <host>. Processes on other hosts will be unable to communicate with this process.

TAG

CORBA_USING_LOOPBACK

COMMENT

This messages indicates that a process will be unable to communicate with processes located on other hosts. Objects the affected process will be advertising themselves to other processes using the loopback address, and as such, processes on other hosts will fail to be able to communicate with objects this process.

CAUSE

Host name resolution resolves to 127.0.0.1 instead of a proper IP address.

ACTION

Check the /etc/hosts file for an entry that corresponding to this host name that maps to 127.0.0.1. Also check DNS and host name resolution configuration.

Netcool/Proviso Error Messages Guide, Version 5.2 55

Page 72: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10056

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

SLA features are disabled

TAG

SLADISABLED

COMMENT

SLA features are disabled but the application has attempted to use some SLA related features such as RCM or the PBL COL_FORMULAS feature.

CAUSE

The application has attempted to use some SLA related features such as RCM or the PBL COL_FORMULAS feature but SLA features are disabled.

ACTION

Enable SLA features.

56 Netcool/Proviso Error Messages Guide, Version 5.2

Page 73: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10057

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

N/A

TAG

OP_TS_OLD_NEW_LABEL

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 57

Page 74: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10058

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

N/A

TAG

OP_PROCESS_SLICE_END

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

58 Netcool/Proviso Error Messages Guide, Version 5.2

Page 75: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10059

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

N/A

TAG

OP_PROCESS_SLICE_END

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 59

Page 76: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10060

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Reason: <1s>

TAG

UNABLE_TO_CONTACT_CMGR

COMMENT

An error occurred while contacting the CMGR.

CAUSE

Connectivity problem between CME and CMGR or CNS not running or CMGR not running.

ACTION

Check connectivity between CME and CMGR.

60 Netcool/Proviso Error Messages Guide, Version 5.2

Page 77: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10061

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Nodes Found: <1p>

TAG

RCM_NODE_NAMES

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 61

Page 78: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10062

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Reason: <reason>

TAG

UNABLE_TO_CONTACT_CMGR

COMMENT

RCM cannot contact CMGR to obtain CME labels.

CAUSE

CMGR is not running or poor connectivity between RCM and CMGR.

ACTION

Check that CMGR is running and check connectivity between RCM and CMGR.

62 Netcool/Proviso Error Messages Guide, Version 5.2

Page 79: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10063

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

CME Labels Found: <1p>

TAG

CME_LABELS

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 63

Page 80: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10064

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Recomp Values don’t match: TS <1p>, Existing wrapper: <3p>, incoming wrapper: <4p>

TAG

OP_STATE_DIFF_RECOMP_VALUE

COMMENT

There is a mismatch between existing and new recomputed values during the operator state upgrade.

CAUSE

Technical error or corrupted state.

ACTION

Contact IBM Technical Support.

64 Netcool/Proviso Error Messages Guide, Version 5.2

Page 81: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10065

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

Merging multiple BOFs to: <outputFilename>

TAG

MERGING_BOFS

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 65

Page 82: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10066

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

Sorting BOF: <bofFilename>

TAG

SORTING_BOF

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

66 Netcool/Proviso Error Messages Guide, Version 5.2

Page 83: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10100

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to process response: "<response>" from <host>:<port> with error: "<error detail>"

TAG

ERROR_3002CLIENT

COMMENT

Unexpected response to 3002 request (request to SNMP Collector).

CAUSE

Communications failure.

ACTION

If the problem persists, contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 67

Page 84: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10101

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Lost response: <response>

TAG

ERROR_3002CLIENT

COMMENT

Unexpected response to 3002 request (request to SNMP Collector).

CAUSE

Communications failure.

ACTION

If the problem persists, contact IBM Technical Support.

68 Netcool/Proviso Error Messages Guide, Version 5.2

Page 85: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10102

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Killed sqlldr pid=<process id> , result=<result>

TAG

SQLLDRKILL

COMMENT

Piped merge did not complete, LDR kills Oracle SQL loader.

CAUSE

Communications failure or database failure.

ACTION

If the problem persists, contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 69

Page 86: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10103

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Killing stuck sqlldr pid=<process id> , result=<result>

TAG

SQLLDRSTUCK

COMMENT

An instance of stuck Oracle SQL loader was found before starting piped merge. LDR kills stuck instance.

CAUSE

Previous operation resulted in LDR failure.

ACTION

If the problem persists, contact IBM Technical Support.

70 Netcool/Proviso Error Messages Guide, Version 5.2

Page 87: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10104

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

{Oracle error message}

TAG

ORASQLLDR

COMMENT

Oracle error encountered during database load. The actual error message is displayed.

CAUSE

Oracle load failure.

ACTION

If the problem persists, contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 71

Page 88: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10105

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

/usr/bin/sqlldr does not exist

TAG

ORASQLLDR

COMMENT

Oracle SQL loader task is not found.

CAUSE

Check Oracle installation and Netcool/Proviso SQL loader configuration settings.

ACTION

N/A

72 Netcool/Proviso Error Messages Guide, Version 5.2

Page 89: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10106

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

Error: this should not happen All loading has stopped because of a fatal error (see previous error message in log). To resume loading, remove {stop file}

TAG

LOADSTOP

COMMENT

Attempt to load end-of-period data failed. Loading is stopped pending manual intervention.

CAUSE

Database failure or corrupted data.

ACTION

Fix the problem and remove STOP file in the loaded (or daily loader) root directory. If the problem persists, contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 73

Page 90: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10107

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

<stored procedure name> - <error details>

TAG

STOREDPROCERR

COMMENT

Storage procedure invocation failed.

CAUSE

Database failure.

ACTION

Check that database is running and accessible. If the problem persists, contact IBM Technical Support.

74 Netcool/Proviso Error Messages Guide, Version 5.2

Page 91: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10108

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to get next metric record from {file name}

TAG

MERGESORTERR

COMMENT

Failure to read record from one of the input files.

CAUSE

File system failure.

ACTION

If the problem persists, contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 75

Page 92: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10109

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Recovery file {dataFile} not found, recovery failed

TAG

RECOVERYFAILURE

COMMENT

Recovery file does not exist.

CAUSE

File has been deleted or is corrupted. Data is not recovered.

ACTION

Data is lost.

76 Netcool/Proviso Error Messages Guide, Version 5.2

Page 93: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10110

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

A SQL error has occurred for the SQL statement: {sql} - {error detail}

TAG

SQLERR

COMMENT

Non-fatal SQL error.

CAUSE

Not enough privileges or database failure.

ACTION

Fix the problem. If the problem persists, contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 77

Page 94: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10111

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error: <error message>. Unable to get disk consumption for dir: <directory>

TAG

FLOW_CTRL_QUOTA_FAILURE

COMMENT

An error occured while trying to get disk consumption for a disk usage server root directory.

CAUSE

Du command is missing or has invalid permissions or du is failing to complete because of an operating system issue.

ACTION

Try to run the du command manually on the same directory to see what error occurs.

78 Netcool/Proviso Error Messages Guide, Version 5.2

Page 95: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10112

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed CORBA Lookup

TAG

CORBA_LOOKUP_ERR

COMMENT

Naming server cannot be accessed or failed to look up object in the naming service.

CAUSE

Netcool/Proviso Corba Name Server is not running or network connection issue.

ACTION

Start CNS or check network.

Netcool/Proviso Error Messages Guide, Version 5.2 79

Page 96: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10113

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed CORBA name registration.

TAG

CORBA_REG_ERR

COMMENT

Channel component failed to register with Corba Naming Service.

CAUSE

Netcool/Proviso Corba Name Server is not running, network connection issue or the port is in use by another process.

ACTION

Start CNS, check network and check that port is not in use.

80 Netcool/Proviso Error Messages Guide, Version 5.2

Page 97: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10114

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to start CORBA service.

TAG

CORBA_START_ERR

COMMENT

Failed to start Corba for channel component.

CAUSE

Configuration problem.

ACTION

Check configuration file conf/dc.config.

Netcool/Proviso Error Messages Guide, Version 5.2 81

Page 98: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10115

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to stop CORBA service.

TAG

CORBA_STOP_ERR

COMMENT

Failed to stop Corba for channel component.

CAUSE

Configuration problem.

ACTION

Check configuration file conf/dc.config.

82 Netcool/Proviso Error Messages Guide, Version 5.2

Page 99: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10117

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

No metadata resources loaded from database...

TAG

NO_RESOURCES

COMMENT

Metadata load did not load any resources.

CAUSE

Data has not been inventoried yet.

ACTION

Make sure inventory has run.

Netcool/Proviso Error Messages Guide, Version 5.2 83

Page 100: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10118

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

Piped Merge Error

TAG

MERGE_ERROR

COMMENT

Piped merge did not complete, LDR kills Oracle SQL loader.

CAUSE

Communications failure or database failure.

ACTION

If the problem persists, contact IBM Technical Support.

84 Netcool/Proviso Error Messages Guide, Version 5.2

Page 101: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10119

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Out of order record: <record>

TAG

OUT_OF_ORDER_RECORDS

COMMENT

Out of order record in BOF file.

CAUSE

Probable file corruption.

ACTION

Contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 85

Page 102: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10120

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error: <error_description>, result: <result_description>, log: <log_contents>

TAG

SFTPERR

COMMENT

General SFTP error.

CAUSE

Communications problem or FTP does not have enough privileges.

ACTION

Check the DataChannel configurationuration file conf/dc.config.

86 Netcool/Proviso Error Messages Guide, Version 5.2

Page 103: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10121

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to connect to remote host: <host> <error>

TAG

SFTP_CONNECTERR

COMMENT

FTP failed to connect to specified host.

CAUSE

Communications problem or FTP does not have enough privileges.

ACTION

Check the DataChannel configurationuration file conf/dc.config.

Netcool/Proviso Error Messages Guide, Version 5.2 87

Page 104: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10122

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

The failure limit of {count}, failed transfers in a row has been exceeded. Transferring discontinued until after poll interval

TAG

MAXFAIL

COMMENT

FTP failed to transfer file after several retries.

CAUSE

Communications problem or FTP does not have enough privileges.

ACTION

Check the DataChannel configurationuration file conf/dc.config.

88 Netcool/Proviso Error Messages Guide, Version 5.2

Page 105: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10123

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to change remote working dir: <1s>

TAG

FTPERR

COMMENT

FTP failed to change to specified directory.

CAUSE

Communications problem or FTP does not have enough privileges.

ACTION

Check the DataChannel configurationuration file conf/dc.config.

Netcool/Proviso Error Messages Guide, Version 5.2 89

Page 106: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10124

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to get remote file <uri> because: <error description>

TAG

FTPERR

COMMENT

There was a failure when attempting to retrieve a file using FTP.

CAUSE

Communications problem or FTP user does not have appropriate permissions.

ACTION

Check the DataChannel configuration file ($DC_HOME/conf/dc.config).

90 Netcool/Proviso Error Messages Guide, Version 5.2

Page 107: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10125

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to make local dir: {localDirPath}

TAG

FTPERR

COMMENT

FTP failed to create specified directory.

CAUSE

Communications problem or FTP does not have enough privileges.

ACTION

Check the DataChannel configurationuration file conf/dc.config.

Netcool/Proviso Error Messages Guide, Version 5.2 91

Page 108: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10126

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to remove remote directory: <1s>

TAG

FTPERR

COMMENT

FTP failed to remove specified directory.

CAUSE

Communications problem or FTP does not have enough privileges.

ACTION

Check the DataChannel configurationuration file conf/dc.config.

92 Netcool/Proviso Error Messages Guide, Version 5.2

Page 109: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10127

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to remove remote file: {host name}:{remoteFile}

TAG

FTPERR

COMMENT

FTP failed to remove specified file.

CAUSE

Communications problem or FTP does not have enough privileges.

ACTION

Check the DataChannel configurationuration file conf/dc.config.

Netcool/Proviso Error Messages Guide, Version 5.2 93

Page 110: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10128

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to remove remote close hour file: <1s>

TAG

FTPERR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

94 Netcool/Proviso Error Messages Guide, Version 5.2

Page 111: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10129

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

FTPERR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 95

Page 112: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10130

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

SQL insert of update for <object> failed, stmt=<statement>

TAG

SQL_INSERT_UPDATE_FAILED

COMMENT

Insert or update failed.

CAUSE

Database error.

ACTION

Check Database connectivity.

96 Netcool/Proviso Error Messages Guide, Version 5.2

Page 113: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10131

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

<1s> -- unable to establish a connection to <2s>

TAG

CONNECTION_ERROR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 97

Page 114: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10132

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed renaming file from: {source file} to: {dest file}

TAG

COMMENT

FTP failed to rename specified file.

CAUSE

Communications problem or FTP does not have enough privileges.

ACTION

Check the DataChannel configurationuration file conf/dc.config.

98 Netcool/Proviso Error Messages Guide, Version 5.2

Page 115: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10133

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

There is more than one top-level stream operator specified

TAG

MULTIPLE_ROOT_OPERATORS

COMMENT

The structure of the UBA operators is invalid. There is more than one operator that has no output operators. Operators without any outputs are called root operators and are the ones that actually emit metrics.

CAUSE

A bug in the tech pack code running on the UBA.

ACTION

Contact IBM Technical Support for help with a possible tech pack bug.

Netcool/Proviso Error Messages Guide, Version 5.2 99

Page 116: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10134

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

File <file name> is to be reprocessed because processing starts at <timestamp>

TAG

FILE_TO_BE_REPROCESSED

COMMENT

A file needs to be reprocessed after a restart of the UBA.

CAUSE

The UBA was bounced.

ACTION

No action is necessary.

100 Netcool/Proviso Error Messages Guide, Version 5.2

Page 117: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10135

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error during <calculate>( ) formula fid=<formula id>, error=<error>

TAG

CALC_ERROR

COMMENT

An error occured during the calculate() method.

CAUSE

Syntax error in calculate methods or other logical code error in calculate method.

ACTION

Check formula syntax, check formula arguments, protect access to tuple lists.

Netcool/Proviso Error Messages Guide, Version 5.2 101

Page 118: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10136

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Invalid formula result <value> for formula <formula>, error=<error>

TAG

INVALID_FORMULA_RESULT

COMMENT

An error occurred while producing a formula result.

CAUSE

Syntax error or other logical code error.

ACTION

Check formula code, check formula arguments, especially returned value.

102 Netcool/Proviso Error Messages Guide, Version 5.2

Page 119: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10137

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

<tuple> does not understand: <message>

TAG

BAD_TUPLE

COMMENT

A bad tuple was encountered.

CAUSE

A misconfiguration or error in the tech pack.

ACTION

Check for iFixes for the tech pack that correct the issue.

Netcool/Proviso Error Messages Guide, Version 5.2 103

Page 120: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10138

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

{dataFilename} contains data for more than one <period>, as specified by TIME_GRANULARITY setting.

TAG

FILETOOBIG

COMMENT

N/A

CAUSE

Inconsistent setting for TIME_GRANULARITY between various DC components.

ACTION

Check the DataChannel configurationuration file conf/dc.config.

104 Netcool/Proviso Error Messages Guide, Version 5.2

Page 121: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10139

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

Can’t load, SLE is already running...

TAG

SLE_ALREADY_RUNNING

COMMENT

Ca not load, SLE is already running.

CAUSE

User error.

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 105

Page 122: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10140

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to get local timezone - Using default secondsFromGMT: <seconds>

TAG

LOCAL_TZ_FAILURE

COMMENT

An error ocurred while trying to establish the local timezone. We will use the default seconds from GMT.

CAUSE

Unknown.

ACTION

Contact IBM Technicalical Support.

106 Netcool/Proviso Error Messages Guide, Version 5.2

Page 123: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10141

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

Error: this should not happen All loading has stopped because of a fatal error (see previous error message in log). To resume loading, remove {stop file}

TAG

LOADSTOP

COMMENT

Attempt to load recomputed data failed. Loading is stopped pending manual intervention.

CAUSE

Database failure or corrupted data.

ACTION

Fix the problem and remove STOP file in the recomp root directory. If problem persists, contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 107

Page 124: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10142

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

Error: this should not happen All running has stopped because of a fatal error (see previous error message in log). To resume running, remove {stop file}

TAG

RUNSTOP

COMMENT

Attempt to recover recomputation failed. Running is stopped pending manual intervention.

CAUSE

Corrupted data.

ACTION

Fix the problem and remove STOP file in the recomp root directory. If problem persists, contact IBM Technical Support.

108 Netcool/Proviso Error Messages Guide, Version 5.2

Page 125: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10143

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Can’t unload, SLE <slelabel> is not currently running

TAG

SLE_NOT_RUNNING

COMMENT

Ca not unload, SLE is not currently running.

CAUSE

User error.

ACTION

Do not try to move an SLE that is not running.

Netcool/Proviso Error Messages Guide, Version 5.2 109

Page 126: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10144

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Can’t start SLE <slelabel> <cmelabel> is not owner of the filesystem

TAG

NOT_OWNER

COMMENT

Ca not start SLE, current CME is not owner of the filesystem.

CAUSE

Interrupted transfer of an SLE between 2 CMEs. Let the transfer complete.

ACTION

Contact IBM Technical Support.

110 Netcool/Proviso Error Messages Guide, Version 5.2

Page 127: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10145

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed looking up PvURL (from AMGR) for directory <directory>

TAG

PVURL_LOOKUP_FAILED

COMMENT

Failed looking up PvURL for directory from AMGR.

CAUSE

AMGR or CMGR is unavailable or DUS is misconfigured in AMGR section of config.

ACTION

Ensure AMGR,CMGR are running and check the DUS seciton of the AMGR config.

Netcool/Proviso Error Messages Guide, Version 5.2 111

Page 128: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10146

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Tenuring of load sets turned off because too much work

TAG

TENURE_SKIP

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

112 Netcool/Proviso Error Messages Guide, Version 5.2

Page 129: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10147

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Log initialization error: <1s>

TAG

LOG_INIT_ERROR

COMMENT

Proceedable error during initialization of Datachannel logger (reason given).

CAUSE

Configuration error (that is, bad resource bundle file).

ACTION

Check error message, verify and change configuration.

Netcool/Proviso Error Messages Guide, Version 5.2 113

Page 130: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10148

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error: <errorDescription> acquiring file: <sourcePvUrl> to: <destinationPvURL>

TAG

ACQUISITION_ERROR

COMMENT

An error occurred while acquiring an input file.

CAUSE

File manually deleted just before acquisition.

ACTION

Make sure that no manual file deletes are hapening and that file permissions are set properly on the source file.

114 Netcool/Proviso Error Messages Guide, Version 5.2

Page 131: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10149

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error collecting input files from inputDirPvURL

TAG

ACQUISITION_ERROR

COMMENT

An error occurred while collecting input files from inputDirPvURL. Upstream CMEs publish their outputDirPvURL so that downstream LDRs can use these as a inputDirPvURL. LDR looks up the outputDirPvURL for each of its INPUT_COMPONENTS in the configuration.

CAUSE

1. INPUT_COMPONENTS not set to a valid list of CMEs. 2. CME published an invalid outputDirPvURL.

ACTION

1. Review the error shown in this log message and make sure that the inputDirPvUrl is valid. 2. Check the configuration settings for disk usage server (DUS). 3. Try to do a file copy or ftp/sftp get from this inputDirPvURL to make sure that it is accessible.

Netcool/Proviso Error Messages Guide, Version 5.2 115

Page 132: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10150

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed testing for running application: <application name> with error: <error detail>

TAG

ISRUNAPPERR

COMMENT

AMGR received an error while trying to check if an application is running.

CAUSE

System error, possibly system running out of resources.

ACTION

Check system status.

116 Netcool/Proviso Error Messages Guide, Version 5.2

Page 133: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10151

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed killing application: <application name> with error: <error detail>

TAG

KILLERR

COMMENT

AMGR received an error while trying to kill an application.

CAUSE

System is overloaded or connection problem or application is not running.

ACTION

Check system status.

Netcool/Proviso Error Messages Guide, Version 5.2 117

Page 134: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10152

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed starting application: <application name> with error: <error detail>

TAG

STARTERR

COMMENT

AMGR received an error while trying to start an application.

CAUSE

System is overloaded or connection problem.

ACTION

Check system status.

118 Netcool/Proviso Error Messages Guide, Version 5.2

Page 135: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10153

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed getting status from application: <application name> with error: <error detail>

TAG

STATUSERR

COMMENT

AMGR received an error while trying to get the status of an application.

CAUSE

System is overloaded or connection problem.

ACTION

Check system status.

Netcool/Proviso Error Messages Guide, Version 5.2 119

Page 136: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10154

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed stopping application: <application name> with error: <error detail>

TAG

STOPERR

COMMENT

AMGR received an error while trying to stop an application.

CAUSE

System is overloaded.

ACTION

Check system status.

120 Netcool/Proviso Error Messages Guide, Version 5.2

Page 137: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10155

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

No PID found when trying to kill application: <application name> that started with command line: <command line>

TAG

NOPID

COMMENT

AMGR failed to kill the specified application.

CAUSE

Application is not running any more or system is overloaded.

ACTION

Check system status.

Netcool/Proviso Error Messages Guide, Version 5.2 121

Page 138: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10156

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

N/A

TAG

CONFIG_IN_DB_ERR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

122 Netcool/Proviso Error Messages Guide, Version 5.2

Page 139: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10157

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error: <error message>. Unable to get disk free space for dir: <directory>

TAG

FLOW_CTRL_FS_FAILURE

COMMENT

An error occured while trying to get disk free space for a disk usage server root directory.

CAUSE

Statvfs failed. libproviso.so could be missing or have invalid permissions.

ACTION

Check that libproviso.so is available and has proper permissions.

Netcool/Proviso Error Messages Guide, Version 5.2 123

Page 140: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10160

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Collector unknown for realtime

TAG

ERR_RTDS

COMMENT

Collector specified in real-time data services request is not found.

CAUSE

Configuration problem.

ACTION

Make sure collector is running. Check configuration.

124 Netcool/Proviso Error Messages Guide, Version 5.2

Page 141: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10161

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to write data to the subscriber: {error detail}

TAG

ERR_RTDS

COMMENT

Failure to deliver real-time subsription data to subscriber.

CAUSE

Communications problem (stale connection).

ACTION

Problem should correct itself.

Netcool/Proviso Error Messages Guide, Version 5.2 125

Page 142: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10162

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Subscription invalid for realtime

TAG

ERR_RTDS

COMMENT

The subscription request is invalid due to bad resource or incorrect formula in the request.

CAUSE

This depends on the chart that generated the realtime subscription request.

ACTION

Make sure the resource and metric are correctly defined in the database for the realtime chart that fails its subscription request.

126 Netcool/Proviso Error Messages Guide, Version 5.2

Page 143: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10163

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Collector unavailable for realtime

TAG

ERR_RTDS

COMMENT

Collector specified in real-time data services request is not available.

CAUSE

Connectivity problem; collector down; configuration problem.

ACTION

Make sure collector is running. Check connectivity and configuration.

Netcool/Proviso Error Messages Guide, Version 5.2 127

Page 144: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10164

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Router Id <router id> is not Saa compatible

TAG

NON_SAA_ROUTER

COMMENT

Attempt to use a Cisco SAA router feature with a non SAA router.

CAUSE

N/A

ACTION

N/A

128 Netcool/Proviso Error Messages Guide, Version 5.2

Page 145: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10165

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Missing mandatory attribute: <attribute name>

TAG

MISSING_PROBE_ATTRIBUTE

COMMENT

A mandatory attribute is missing from a probe.

CAUSE

A problem in DataView resulted in an attempt to create a probe with missing attributes.

ACTION

Check the health of DataView.

Netcool/Proviso Error Messages Guide, Version 5.2 129

Page 146: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10166

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unknown router Id <router id>

TAG

UNKOWN_ROUTER_ID

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

130 Netcool/Proviso Error Messages Guide, Version 5.2

Page 147: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10167

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unknown or incomplete target Id <target_id>

TAG

TARGETID

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 131

Page 148: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10168

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Invalid arguments to API call to <apiCall>

TAG

COLL_INVALID_ARGS

COMMENT

The collector library has been called with invalid arguments.

CAUSE

A CORBA client called the probe monitor with invalid arguments.

ACTION

N/A

132 Netcool/Proviso Error Messages Guide, Version 5.2

Page 149: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10169

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

SNMP Timeout or invalid community string on target Id: <target_id>, with SNMP agent: <target_name>

TAG

SNMPTIMEOUT

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 133

Page 150: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10170

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

<description>

TAG

PROBE_MONITOR_GENERAL_ERROR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

134 Netcool/Proviso Error Messages Guide, Version 5.2

Page 151: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10171

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

No sub-element with id: <subelement id>

TAG

UNKNOWN_SUBELEMENT

COMMENT

A CORBA client to the SAA probe monitor issued a request with an invalid sub-element id.

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 135

Page 152: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10172

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error resyncing probes for router <sub-element id>: <error description>

TAG

PROBE_RESYNC_FAILED

COMMENT

An error occurred while attempting to resync the probes on a router.

CAUSE

SNMP communication failure between the collector and router.

ACTION

N/A

136 Netcool/Proviso Error Messages Guide, Version 5.2

Page 153: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10173

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Probe "<probe index>" on router for sub-element <subelement id> was redeployed.

TAG

PROBE_RESYNC

COMMENT

A monitored probe was redeployed on a router to synchronize its settings with those stored in Proviso.

CAUSE

A probe in a router was detected to be out of sync with the persistent data.

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 137

Page 154: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10174

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unknown collector error

TAG

UNKNOWN_ERROR

COMMENT

An unknown error has occurred.

CAUSE

N/A

ACTION

N/A

138 Netcool/Proviso Error Messages Guide, Version 5.2

Page 155: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10175

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unknown probe at index ’<probe index>’ on router Id# <sub-element id>.

TAG

PROBE_UNKNOWN

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 139

Page 156: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10176

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unknown probe at index ’<probe index>’ on router Id# <sub-element id>.

TAG

PROBE_UNKNOWN

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

140 Netcool/Proviso Error Messages Guide, Version 5.2

Page 157: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10177

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Router <sub-element id> does not support probes of type ’<name>’

TAG

UNSUPPORTED_PROBE_TYPE

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 141

Page 158: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10178

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Router <sub-element id> appears to have been rebooted, probes will be resynced

TAG

ROUTER_REBOOTED

COMMENT

A router reboot was detected.

CAUSE

A reboot was detected by examining sysUpTime on the router.

ACTION

No action necessary.

142 Netcool/Proviso Error Messages Guide, Version 5.2

Page 159: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10179

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Resyncing probes on router <sub-element id>

TAG

PROBE_RESYNC

COMMENT

Probes in a router are being resynced with the probe settings stored in Proviso.

CAUSE

A reboot was detected, a manual resync request was issues, or a scheduled resync is occurring.

ACTION

No action necessary.

Netcool/Proviso Error Messages Guide, Version 5.2 143

Page 160: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10180

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error trying to detect reboot of router <sub-element id>: <error description>

TAG

REBOOT_DETECTION_FAILED

COMMENT

An error occurred while attempting to whether a router was rebooted.

CAUSE

SNMP communication failure between the collector and router.

ACTION

N/A

144 Netcool/Proviso Error Messages Guide, Version 5.2

Page 161: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10181

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

This collector is currently inactive

TAG

COLLECTOR_INACTIVE

COMMENT

A collector client sent a probe configuration message to an inactive collector.

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 145

Page 162: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10182

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to load probe monitor configuration from the database: <description>

TAG

PROBE_MONITOR_DB_FAILURE

COMMENT

Failed to load the probe monitor configuration from the database.

CAUSE

Database is down or unable to communication with the database server.

ACTION

Investigate connectivity with the database.

146 Netcool/Proviso Error Messages Guide, Version 5.2

Page 163: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10183

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

The server is too busy to accept new probe monitoring requests.

TAG

SERVER_BUSY

COMMENT

Too many probe monitoring requests are currently active. Rejecting further requests.

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 147

Page 164: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10184

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

The router is too busy to accept new probe monitoring requests.

TAG

ROUTER_BUSY

COMMENT

Too many probe monitoring requests are currently active for the given router. Rejecting further requests.

CAUSE

N/A

ACTION

N/A

148 Netcool/Proviso Error Messages Guide, Version 5.2

Page 165: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10185

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Router <sub-element id> is currently busy, skipping probe check

TAG

ROUTER_BUSY

COMMENT

A router check can not be completed at that time.

CAUSE

Router is already busy executing other SNMP requests.

ACTION

No action necessary.

Netcool/Proviso Error Messages Guide, Version 5.2 149

Page 166: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10186

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unsupported attribute ’<attribute name>’ for probe of type ’<name>’

TAG

UNSUPPORTED_ATTRIBUTE

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

150 Netcool/Proviso Error Messages Guide, Version 5.2

Page 167: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10187

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Target Id <sub-element id> is currently busy, try again later (est. <max_time> seconds)

TAG

BUSY

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 151

Page 168: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10188

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to modify probe type at index ’<probe index>’ on router Id# <sub-element id>. Use delete/create instead.

TAG

PROBE_MUTATION_REJECTED

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

152 Netcool/Proviso Error Messages Guide, Version 5.2

Page 169: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10189

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

The probe has expired

TAG

PROBE_EXPIRED

COMMENT

A probe has reached its expiration date and should be removed.

CAUSE

The probes expiration date has passed.

ACTION

Remove the probe.

Netcool/Proviso Error Messages Guide, Version 5.2 153

Page 170: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10200

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Moving file caused problem: {aFilename}

TAG

FILE_ERROR

COMMENT

Failed to move (rename) specified file.

CAUSE

Bulk Collector does not have enough privileges or file system failure.

ACTION

Check bulk collector’s configuration file conf/dc.config.

154 Netcool/Proviso Error Messages Guide, Version 5.2

Page 171: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10201

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Moving file to done caused problem: {aFilename}

TAG

FILE_ERROR

COMMENT

Failed to move (rename) specified file.

CAUSE

Bulk Collector does not have enough privileges or file system failure.

ACTION

Check bulk collector’s configuration file conf/dc.config.

Netcool/Proviso Error Messages Guide, Version 5.2 155

Page 172: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10204

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Saved file <file> is not found, ignoring file

TAG

BAD_DATAFILE

COMMENT

Problem when accessing BOF file.

CAUSE

File has been moved or deleted by user.

ACTION

If the problem persists, contact IBM Technical Support.

156 Netcool/Proviso Error Messages Guide, Version 5.2

Page 173: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10205

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

A metadata error occurred - {error detail}

TAG

METADATA_ERROR

COMMENT

The requested metadata is requested without a valid name.

CAUSE

This is due to either malformed input or a bug in the parser code for building metadata names.

ACTION

Analyze input files and contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 157

Page 174: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10206

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

{symbol} is an invalid metric value type

TAG

BAD_TYPE

COMMENT

The parser field descriptions attempt to specify an incorrect value type.

CAUSE

The parser for that format type is broken.

ACTION

Contact IBM Technical Support.

158 Netcool/Proviso Error Messages Guide, Version 5.2

Page 175: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10207

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

No data found in {data type} data file

TAG

EMPTY_FILE

COMMENT

Input bulk file is empty.

CAUSE

Bad input file.

ACTION

Check input data.

Netcool/Proviso Error Messages Guide, Version 5.2 159

Page 176: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10208

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to CD to profile directory: {ftpDirectory}, error: {ftpResult}

TAG

FAILINVENTORY

COMMENT

Bulk collector failed to change directory to remote inventory directory (FTP error).

CAUSE

Communications problem; wrong directory path in configuration file or not enough privileges.

ACTION

Check connectivity and configuration file conf/dc.config.

160 Netcool/Proviso Error Messages Guide, Version 5.2

Page 177: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10209

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to connect to ftp site {host name}, error: {ftpResult}

TAG

FAILINVENTORYSEND

COMMENT

Bulk collector failed to connect to remote inventory directory (FTP error).

CAUSE

Communications problem; wrong host name in configuration file or not enough privileges or loss of connectivity. Specifically ftp result ’Network is unavailable’ means the machine interface is down.

ACTION

Check connectivity and configuration file conf/dc.config.

Netcool/Proviso Error Messages Guide, Version 5.2 161

Page 178: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10210

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to CD to root ftp directory: <ftpDirectory> error: <ftpResult>

TAG

FAILINVENTORYINIT

COMMENT

Bulk collector failed to change directory to remote root inventory directory (FTP error).

CAUSE

Communications problem; wrong directory path in configuration file or not enough privileges.

ACTION

Check connectivity and configuration file conf/dc.config.

162 Netcool/Proviso Error Messages Guide, Version 5.2

Page 179: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10211

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to CD to profile directory: <file> error: <ftpResult>

TAG

FAILINVENTORYINIT

COMMENT

Bulk collector failed to send file to remote inventory directory (FTP error).

CAUSE

Communications problem; wrong directory path in configuration file or not enough privileges.

ACTION

Check connectivity and configuration file conf/dc.config.

Netcool/Proviso Error Messages Guide, Version 5.2 163

Page 180: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10212

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to rename inventory file: {file}, error: {ftpResult}

TAG

FAILINVENTORYSEND

COMMENT

Bulk collector failed rename file in remote inventory directory (FTP error).

CAUSE

Communications problem; or not enough privileges.

ACTION

Check connectivity and configuration file conf/dc.config.

164 Netcool/Proviso Error Messages Guide, Version 5.2

Page 181: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10213

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

{data line}

TAG

BAD_DATALINE

COMMENT

Unexpected input in data file — offending line shown.

CAUSE

Bad data file.

ACTION

Check input data file.

Netcool/Proviso Error Messages Guide, Version 5.2 165

Page 182: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10214

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

{filename} not recognized as a valid bulk stats input file

TAG

BAD_FILE

COMMENT

No valid file format can be identified with specified file.

CAUSE

Bad data file.

ACTION

Check input data file.

166 Netcool/Proviso Error Messages Guide, Version 5.2

Page 183: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10216

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

{error detail} - filename - {exception detail}

TAG

BAD_TIMESTAMP

COMMENT

Error while processing specified file (malformed timestamp).

CAUSE

Bad data file.

ACTION

Check input data file.

Netcool/Proviso Error Messages Guide, Version 5.2 167

Page 184: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10217

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

{error detail} - filename

TAG

BAD_DETECTION

COMMENT

The format type detection algorithms fail to detect this file.

CAUSE

Either the format is unsupported or malformed or the parser is broken.

ACTION

Analyze input files and contact IBM Technical Support.

168 Netcool/Proviso Error Messages Guide, Version 5.2

Page 185: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10218

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

{exception detail}

TAG

BAD_UOW_PROCESS

COMMENT

Internal error while processing specified file.

CAUSE

Bad data file.

ACTION

Contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 169

Page 186: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10219

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

No schema named {schemaName} defined

TAG

BAD_SCHEMA

COMMENT

Error while processing specified file (invalid schema name).

CAUSE

Bad data file.

ACTION

Check input data file.

170 Netcool/Proviso Error Messages Guide, Version 5.2

Page 187: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10220

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Expecting one of s, d, u, x, or % instead of {bad character}

TAG

BAD_TOKEN

COMMENT

Error while processing input data file.

CAUSE

Bad data file.

ACTION

Check input data file.

Netcool/Proviso Error Messages Guide, Version 5.2 171

Page 188: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10221

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Flow control deadlock -- increase file quota

TAG

BAD_DESCRIPTOR

COMMENT

LDR discovered input data, but cannot acquired the data because file quota is too small and there are no acquired files that can be loaded.

CAUSE

File quota for LDR is too small.

ACTION

Consult Abacus, increase LDR file quota and restart the LDR.

172 Netcool/Proviso Error Messages Guide, Version 5.2

Page 189: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10301

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

A communications error occurred between channel manager, application manager and application.

TAG

OTHERCOMMERR

COMMENT

A communications error occurred.

CAUSE

Poor connectivity between CMGR, AMGR and application or CMGR or AMGR are not running.

ACTION

Check connectivity between CMGR, AMGR and application and that CMGR and AMGR.

Netcool/Proviso Error Messages Guide, Version 5.2 173

Page 190: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10302

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

A communications error occurred between command line interface and the channel manager (<reason>)

TAG

CMGRCOMMERR

COMMENT

A communications error occurred.

CAUSE

Poor connectivity between command line interface and the channel manager.

ACTION

Check connectivity between command line interface and the channel manager.

174 Netcool/Proviso Error Messages Guide, Version 5.2

Page 191: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10304

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

<application manager> is unavailable

TAG

HOST_AVAILABLE

COMMENT

Inable to reach application.

CAUSE

Poor connectivity between CMGR and application host.

ACTION

Check connectivity.

Netcool/Proviso Error Messages Guide, Version 5.2 175

Page 192: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10305

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

A database error occured: <error details>

TAG

NRT_DB_UNAVAILABLE

COMMENT

Getting labels failed during near real-time query.

CAUSE

Oracle connectivity problem or Oracle database down.

ACTION

Check connectivity to Oracle.

176 Netcool/Proviso Error Messages Guide, Version 5.2

Page 193: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10306

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed getting metric records from: <application name> with error: <error detail>

TAG

REALTIMEERR

COMMENT

CMGR received an error while trying to get metric records from an application.

CAUSE

Poor connectivity between CMGR host and application host.

ACTION

Check connectivity between CMGR host and application host.

Netcool/Proviso Error Messages Guide, Version 5.2 177

Page 194: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10307

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed testing for running application: <application_name> with error: <error_string>

TAG

ISRUNAPPERR

COMMENT

CMGR received an error while trying to test if an application is running already.

CAUSE

System error, possibly system running out of resources or poor connectivity between CMGR host and application host.

ACTION

Check system status and connectivity between CMGR host and application host.

178 Netcool/Proviso Error Messages Guide, Version 5.2

Page 195: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10308

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed killing application: <application name> with error: <error detail>

TAG

KILLERR

COMMENT

CMGR received an error while trying to kill an application.

CAUSE

Poor connectivity between CMGR host and application host.

ACTION

Check connectivity between CMGR host and application host.

Netcool/Proviso Error Messages Guide, Version 5.2 179

Page 196: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10309

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed starting application: <application name> with error: <error detail>

TAG

STARTERR

COMMENT

CMGR received an error while trying to start an application.

CAUSE

Poor connectivity between CMGR host and application host.

ACTION

Check connectivity between CMGR host and application host.

180 Netcool/Proviso Error Messages Guide, Version 5.2

Page 197: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10310

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed getting status from application: <application name> with error: <error detail>

TAG

STATUSERR

COMMENT

CMGR received an error while trying to get the status of an application.

CAUSE

Poor connectivity between CMGR host and application host.

ACTION

Check connectivity between CMGR host and application host.

Netcool/Proviso Error Messages Guide, Version 5.2 181

Page 198: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10311

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed stopping application: <application name> with error: <error detail>

TAG

STOPERR

COMMENT

CMGR received an error while trying to stop an application.

CAUSE

Poor connectivity between CMGR host and application host.

ACTION

Check connectivity between CMGR host and application host.

182 Netcool/Proviso Error Messages Guide, Version 5.2

Page 199: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10312

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Abandoned request because client disconnected prematurely

TAG

ABANDONREQUEST

COMMENT

Abandoned request because client disconnected prematurely.

CAUSE

Poor connectivity from dccmd to AMGR and CMGR.

ACTION

Check connectivity.

Netcool/Proviso Error Messages Guide, Version 5.2 183

Page 200: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10313

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

No configured component matches name "<name>", application "<application>" and host "<hostname>"

TAG

NO_COMPONENT_MATCHED

COMMENT

No component matches the given name, application and host patterns.

CAUSE

The name, application or host patterns were specified incorrectly.

ACTION

Check the name, application and host patterns.

184 Netcool/Proviso Error Messages Guide, Version 5.2

Page 201: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10314

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to contact: <application name> with error: <error detail>

TAG

APPUNAVAILABLE

COMMENT

CMGR received an error while trying to contact an application.

CAUSE

Poor connectivity between CMGR host and application host.

ACTION

Check connectivity between CMGR host and application host.

Netcool/Proviso Error Messages Guide, Version 5.2 185

Page 202: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10315

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

NO_CME_CONFIGURED

COMMENT

No configured CME matches the given CME name.

CAUSE

A CME that has not been configured is needed according to PBL.

ACTION

Add an entry to configuration for the CME in question and bounce CMGR, then start that CME.

186 Netcool/Proviso Error Messages Guide, Version 5.2

Page 203: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10316

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

SLE_ALREADY_ASSIGNED

COMMENT

SLE is already assigned to another CME.

CAUSE

SLE needs to unloaded prior be be reassigned to another CME.

ACTION

Contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 187

Page 204: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10317

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

SLE_NOT_ASSIGNED

COMMENT

SLE has not been assigned to any CME.

CAUSE

SLE needs to be loaded in a CME.

ACTION

Contact IBM Technical Support.

188 Netcool/Proviso Error Messages Guide, Version 5.2

Page 205: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10318

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

CANT_MOVE_SLE

COMMENT

Currently do not support moving SLEs across file systems.

CAUSE

Running two cmes on different file systems.

ACTION

Contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 189

Page 206: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10400

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

A file read error: <error description> occurred after processing <count> records in file: <file name>

TAG

FILE_READ_ERROR

COMMENT

An error occurred while trying to read and process tuples in a file.

CAUSE

The input file is corrupt.

ACTION

Check the input file.

190 Netcool/Proviso Error Messages Guide, Version 5.2

Page 207: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10401

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Metric record <metric record> <error detail>

TAG

BAD_RECORD

COMMENT

CME was sent data that is either not covered by requests or is in an invalid format.

CAUSE

Metric not covered by request or invalid data format.

ACTION

Check input data.

Netcool/Proviso Error Messages Guide, Version 5.2 191

Page 208: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10402

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

<count> bad records were rejected for mid <metric id>

TAG

BAD_RECORDS

COMMENT

Lists the number of bad records in input file by metric id.

CAUSE

Misconfiguration of requests or resource groups.

ACTION

Review requests and resource groups for requests.

192 Netcool/Proviso Error Messages Guide, Version 5.2

Page 209: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10404

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Bad cme.lastHour file

TAG

BAD_LASTHOUR

COMMENT

Lasthour file is corrupted.

CAUSE

N/A

ACTION

Contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 193

Page 210: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10405

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Bad request: <request>, sub-element: <resource>: Generic formula <gerneric id> is not loaded

TAG

BAD_REQUEST

COMMENT

If it is an SNMP generic formula, the collector already sends us metrics with generic formula ID, so the generic formula should exist.

CAUSE

Request’s formula refers to a generic id that does not exists.

ACTION

Check request’s formula to make sure generic formula exists.

194 Netcool/Proviso Error Messages Guide, Version 5.2

Page 211: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10406

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Metric id: {metric id} invalid

TAG

INVALID_METRICID

COMMENT

Formula refers to invalid input binding.

CAUSE

Formula for specified binding was deleted.

ACTION

Check formula definition.

Netcool/Proviso Error Messages Guide, Version 5.2 195

Page 212: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10407

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Formula was removed because of compile error: {error detail}

TAG

BAD_FORMULA

COMMENT

Formula could not be loaded because of compile error.

CAUSE

Invalid formula source.

ACTION

Check formula definition.

196 Netcool/Proviso Error Messages Guide, Version 5.2

Page 213: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10408

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

An error occured while running building output mr for formula: {formula class name}, error: {exception description}, info: {debug info}

TAG

FORMULA_BUILD_ERR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 197

Page 214: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10409

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

An error occured while running calculation for formula: {formula class name}, error: {exception description}, info: {debug info}

TAG

FORMULA_CALC_ERR

COMMENT

Error while computing formula value.

CAUSE

N/A

ACTION

N/A

198 Netcool/Proviso Error Messages Guide, Version 5.2

Page 215: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10410

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Compiler error for Smalltalk formula: {class name}, -> {exception description}

TAG

FORMULA_ERROR

COMMENT

Formula caused compile error.

CAUSE

Invalid formula source.

ACTION

Check formula definition.

Netcool/Proviso Error Messages Guide, Version 5.2 199

Page 216: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10411

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

{exception description}

TAG

THRESH_ERROR

COMMENT

A failure has occurred in threshold processing.

CAUSE

Unknown - Depends on specific exception.

ACTION

Send Exception details to Support team.

200 Netcool/Proviso Error Messages Guide, Version 5.2

Page 217: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10412

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Got <duplicate count> duplicate records, Discarded <discarded count>, Total of <total count> for <timeseries id>

TAG

DISCARDED_RECORDS

COMMENT

CME discovered and discarded duplicate records when flushing them to disk.

CAUSE

Same data sent to the same CME twice or error in handling of RCM data or normal CME data.

ACTION

Check for duplicate data being sent to CME. contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 201

Page 218: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10413

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error sending trap, resetting SNMP engine

TAG

SNMP_TRAP_SENDER

COMMENT

Error occured during sending trap.

CAUSE

Communications problems.

ACTION

Check connectivity.

202 Netcool/Proviso Error Messages Guide, Version 5.2

Page 219: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10414

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Got <duplicate count> duplicate records, Discarded <discarded count>, Total of <total count>

TAG

COMMENT

CME found duplicate records or some records were discarded because of invariant change.

CAUSE

Duplicate collection requests or invariant changed.

ACTION

Check system configuration. In case of invariant change the system should handle it automatically.

Netcool/Proviso Error Messages Guide, Version 5.2 203

Page 220: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10415

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Configuration file <filename> is newer than state file <filename>

TAG

CONFLICTING_CFG_STATE

COMMENT

The configuration file is newer than the state file.

CAUSE

The configuration file is newer than the state file.

ACTION

Check system configuration.

204 Netcool/Proviso Error Messages Guide, Version 5.2

Page 221: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10416

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

General failure in code that creates and send a trap PDU

TAG

THRESH_TRAP

COMMENT

N/A

CAUSE

A message like ’Improper Store into Indexable Object’ indicates and attempt to put a string with unicode chars > 255.

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 205

Page 222: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10417

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Mid/Gid/Rid = <mid>/<gid>/<rid>

TAG

BASELINE_STATE_RESET

COMMENT

Reset Baseline state due to missing Baseline History in DB.

CAUSE

Maybe data was manually deleted from DB or Loader is not loading or data from CME arrived outside the remerge window.

ACTION

Check that LDR is loading OK.

206 Netcool/Proviso Error Messages Guide, Version 5.2

Page 223: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10418

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to copy <source URI> to <dest URI>, details: <error details>

TAG

COPY_FAILED

COMMENT

An error occured during an attempt to copy a file.

CAUSE

Source or Destination URI is unreachable or missing or has invalid permissions.

ACTION

Review the error details. Check file permissions. Attempt to copy the source URI to the desitnation URI manually to see what error occurs.

Netcool/Proviso Error Messages Guide, Version 5.2 207

Page 224: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10419

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to delete <URI>, details: <error details>

TAG

DELETE_FAILED

COMMENT

An error occured during an attempt to delete a file.

CAUSE

URI is unreachable or missing or has invalid permissions.

ACTION

Review the error details. Check file permissions. Attempt to delete the source URI manually to see what error occurs.

208 Netcool/Proviso Error Messages Guide, Version 5.2

Page 225: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10420

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to link <source URI> to <dest URI>, details: <error details>

TAG

LINK_FAILED

COMMENT

An error occured during an attempt to link one URI to another.

CAUSE

Hard links are only supported between files on the same file system.

ACTION

Review the error details. Check file permissions. Attempt to link the URIs manually to see what error occurs.

Netcool/Proviso Error Messages Guide, Version 5.2 209

Page 226: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10421

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to move <source URI> to <dest URI>, details: <error details>

TAG

MOVE_FAILED

COMMENT

An error occured during an attempt to move a file.

CAUSE

Move (rename) is only supported between files on the same file system.

ACTION

Review the error details. Check file permissions. Attempt to move (rename) the source URI to the desitnation URI manually to see what error occurs.

210 Netcool/Proviso Error Messages Guide, Version 5.2

Page 227: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10422

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

URI: <souce_code_uri> message: <error_message>

TAG

SYNTAX_ERROR

COMMENT

A syntax error was detecting while compiling ECMAScript code.

CAUSE

A syntax error exists in a UBA script or a CME formula document.

ACTION

Check the syntax in the indicated file and correct it.

Netcool/Proviso Error Messages Guide, Version 5.2 211

Page 228: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10423

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to retrieve file size: <URI>

TAG

FILESIZE_FAILED

COMMENT

Unable to retrieve the file size of a URI.

CAUSE

URI is unavailable or missing or has invalid permissions.

ACTION

Check file permissions. Attempt to check file information for a URI using ls command.

212 Netcool/Proviso Error Messages Guide, Version 5.2

Page 229: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10424

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Copied file size does not match source (source: <source URI> [<source size>] destination: <destination URI> [<desitnation size>])

TAG

FILESIZE_MISMATCH

COMMENT

After a copy the file sizes do not match.

CAUSE

Disk corruption or networking error.

ACTION

Manually copy the source URI to some desintation on the same partition and/or different partition as the destination to see if they are the same file size.

Netcool/Proviso Error Messages Guide, Version 5.2 213

Page 230: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10425

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to copy file, giving up (<uri list>)

TAG

RETRY_LIMIT_EXCEEDED

COMMENT

Retried too many times to copy a file.

CAUSE

URIs are unavailable or missing or have invalid permissions.

ACTION

Check file permissions. Review the error details Attempt to manually copy a URI to see what error occurs.

214 Netcool/Proviso Error Messages Guide, Version 5.2

Page 231: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10426

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Build error on request: <request>, sub-element: <resource>: Generic formula <formula> , reason: <error detail>

TAG

BUILD_ERROR

COMMENT

An error has occurred during the tree build.

CAUSE

Code defect.

ACTION

Contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 215

Page 232: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10427

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

BAD_INPUT

COMMENT

Bad input: cannot resolve <input kind> tsId: <id> from: <db row>.

CAUSE

Plan is inconsistent.

ACTION

Contact IBM Technical Support.

216 Netcool/Proviso Error Messages Guide, Version 5.2

Page 233: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10428

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

No argument with s/n <sequence number> found for <time series> and input: <input time series>

TAG

NO_OPERATOR

COMMENT

When attempting to update a formula input, no argument with the indicated sequence number was found.

CAUSE

Plan is inconsistent or formula definition changed.

ACTION

Contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 217

Page 234: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10429

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

No complex formula for: <1p> in: <2p>

TAG

NO_OPERATOR

COMMENT

No complex formula for: <id>.

CAUSE

Plan is inconsistent.

ACTION

Contact IBM Technical Support.

218 Netcool/Proviso Error Messages Guide, Version 5.2

Page 235: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10430

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Metrics with timestamps starting at <timestamp> were already received - <tupleContainer>

TAG

DUPLICATE_DATA

COMMENT

Metrics have already been received for this time. Duplicate data will be ignored.

CAUSE

A collector has produced duplicate data or some error in the flow of data through the DataChannel has resulted in duplicate data being received.

ACTION

If the tuple container is from a collector, check if that collector is actually producing duplicate data by using bofDump on the output files that it produces.

Netcool/Proviso Error Messages Guide, Version 5.2 219

Page 236: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10431

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Data from label <1p> is not used here

TAG

WRONG_INPUT_LABEL

COMMENT

Data from label <label> is not used here.

CAUSE

Routing map is wrong.

ACTION

Contact IBM Technical Support.

220 Netcool/Proviso Error Messages Guide, Version 5.2

Page 237: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10432

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to write BOF file because of <error description>, will retry

TAG

FILE_WRITE_ERROR

COMMENT

Failed to write tuples to disk.

CAUSE

The disk is full or there is some other issue with the file system.

ACTION

Double check disk space and permissions.

Netcool/Proviso Error Messages Guide, Version 5.2 221

Page 238: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10433

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

Error building time series from: <1p> dure to: <2s>

TAG

BUILD_ERROR_TS

COMMENT

Error building time series from: {db row}, reason: {a reson}.

CAUSE

Plan is inconsistent.

ACTION

Contact Proviso Support.

222 Netcool/Proviso Error Messages Guide, Version 5.2

Page 239: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10434

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

Error building input from: <1p> dure to: <2s>

TAG

BUILD_ERROR_INPUT

COMMENT

Error building input from: {db row}, reason: {a reson}.

CAUSE

Plan is inconsistent.

ACTION

Contact Proviso Support.

Netcool/Proviso Error Messages Guide, Version 5.2 223

Page 240: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10435

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error processing record <record> due to: <error description>

TAG

EROR_PROCESSING_RECORD

COMMENT

An error occurred while processing a record.

CAUSE

There are many possible causes.

ACTION

Take steps to correct the problem based on the information given in the error description.

224 Netcool/Proviso Error Messages Guide, Version 5.2

Page 241: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10437

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

No formula for: <timeseries>

TAG

NO_FORMULA

COMMENT

RCM cannot locate the formula for a timeseries.

CAUSE

Plan is inconsistent. Perhaps a formula was deleted from history.

ACTION

Check plan consistency and that formula exists for timeseries.

Netcool/Proviso Error Messages Guide, Version 5.2 225

Page 242: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10439

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Problem contacting tuple storage, will retry every 60 seconds.

TAG

TUPLE_STORAGE_UNAVAILABLE

COMMENT

RCM cannot contact tuple storage.

CAUSE

Poor connectivity between RCM and remote tuple storage.

ACTION

Check connectivity between RCM and CMEs.

226 Netcool/Proviso Error Messages Guide, Version 5.2

Page 243: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10440

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error running tuple query (will retry in 60 seconds): <error description>’

TAG

TUPLE_QUERY_FAILURE

COMMENT

The recomputation engine has a problem querying other components or the database.

CAUSE

One or more CMEs or FTEs is down or database connectivity has been interrupted.

ACTION

Ensure all CMEs, FTEs and the database are running.

Netcool/Proviso Error Messages Guide, Version 5.2 227

Page 244: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10441

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

A timeout occured while fetching the results of a tuple query. The query will be retried.

TAG

TUPLE_QUERY_FAILURE

COMMENT

A timeout occurred while querying tuples.

CAUSE

The result set is too large or the system is too heavily loaded.

ACTION

Contact IBM Technical Support.

228 Netcool/Proviso Error Messages Guide, Version 5.2

Page 245: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10442

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Remote query of label <label> failed: <reason>

TAG

TUPLE_QUERY_FAILURE

COMMENT

An attempt to query a remote process for data failed.

CAUSE

Remote process is unavailable.

ACTION

Ensure all components are running.

Netcool/Proviso Error Messages Guide, Version 5.2 229

Page 246: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10443

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

INPUT_TIMESTAMP_NOT_SET

COMMENT

A file needs to be partially reprocessed after a restart of the UBA in order to finish processing the file.

CAUSE

The UBA was bounced.

ACTION

No action is necessary.

230 Netcool/Proviso Error Messages Guide, Version 5.2

Page 247: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10444

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to apply repeat modifier <modifier> to schedule <schedule> for <operator>

TAG

FAILED_APPLY_REPEAT_MODIFIER

COMMENT

The system failed to interpret the repeat modifier specified in a formula or in a sub-element property.

CAUSE

A sub-element property specifying a repeat modifer is either missing or invalid.

ACTION

Check the sub-element property used for the repeat modifier and make sure the correct syntax was used. Also verify that the calendar used in the formula is compatible with the property.

Netcool/Proviso Error Messages Guide, Version 5.2 231

Page 248: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10445

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to apply timezone repeat modifier <1s> for <2s>

TAG

FAILED_APPLY_TIMEZONE_MODIFIER

COMMENT

Failed to apply a timezone modifier based on a sub-element property.

CAUSE

The property value is invalid and did not parse correctly.

ACTION

Check sub-element property value used for the timezone modifier.

232 Netcool/Proviso Error Messages Guide, Version 5.2

Page 249: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10446

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Invalid calendar/duration: <calendar name> for <operator>

TAG

INVALID_SCHEDULE_ID

COMMENT

An invalid reference to a calendar or duration was encountered in a formula.

CAUSE

An invalid calendar name or period duration was used in a formula.

ACTION

Double check the calendar name or duration specified in the formula and make sure it is defined using the DataMart calendar manager.

Netcool/Proviso Error Messages Guide, Version 5.2 233

Page 250: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10447

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

<name>: Failed to recover state at or before <timestamp>. No saved state found

TAG

AGGREGATOR_FAILED_RECOVER_STATE

COMMENT

An aggregator in a UBA failed to recover its state from disk.

CAUSE

The state files have been deleted or modified.

ACTION

Check for data loss and determine whether someone may have inadvertently manipulated the UBA’s state files.

234 Netcool/Proviso Error Messages Guide, Version 5.2

Page 251: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10448

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

<name>: Failed to recover state at or before <timestamp>. State may be lost. Will use state for <timestamp> for recovery

TAG

AGGREGATOR_FAILED_RECOVER_STATE

COMMENT

An aggregator in a UBA failed to recover its state from disk. The UBA will attempt to use older aggregator state instead.

CAUSE

The state files have been deleted or modified.

ACTION

Check for data loss and determine whether someone may have inadvertently manipulated the UBA’s state files.

Netcool/Proviso Error Messages Guide, Version 5.2 235

Page 252: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10501

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Invalid profile name <xxxxxxx>

TAG

COMMENT

The definition for the profile ’xxxxx’ cannot be found in the database. Current execution is aborted.

CAUSE

The GUI is out of sync with the database.

ACTION

Refresh or bounce the GUI, to resync the content.

236 Netcool/Proviso Error Messages Guide, Version 5.2

Page 253: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10502

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Missing or unreadeable element rule file <xxxxxx>

TAG

COMMENT

The file inventory_element.txt is missing for executing the profile.

CAUSE

Missing file.

ACTION

Check suggested path, and add corresponding file to that location.

Netcool/Proviso Error Messages Guide, Version 5.2 237

Page 254: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10503

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Missing or unreadeable sub-element rule file <xxxxxx>

TAG

COMMENT

The file inventory_sub-element.txt is missing for executing the profile.

CAUSE

Missing file.

ACTION

Check suggested path, and add corresponding file to that location.

238 Netcool/Proviso Error Messages Guide, Version 5.2

Page 255: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10504

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unknown discovery formula name <xxxxxx>

TAG

COMMENT

A formula specified in files inventory_element.txt or inventory_sub-element.txt is unknown in the database.

CAUSE

Typo error in the formula definition in the file.

ACTION

Check database and file for formula spelling, and fix file.

Netcool/Proviso Error Messages Guide, Version 5.2 239

Page 256: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10505

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Invalid configuration option <xxxxxxx>=<yyyyyyyy>

TAG

COMMENT

One of the configuration parameter for the profile has an invalid value.

CAUSE

Configuration error.

ACTION

Please seek assistance from Micromuse.

240 Netcool/Proviso Error Messages Guide, Version 5.2

Page 257: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10506

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

IVE_TARGET_LOOKUP_FAILED

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 241

Page 258: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10507

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Invalid id: <id> for time series input -- ignored

TAG

INVALID_RECOVERY_RECORD_INPUT

COMMENT

Inconsistent data was found while serializing or deserializing timeseries and input data.

CAUSE

The input was seriealized incorrectly or the formula or resource for this input no longer exist upon reload.

ACTION

Check that the formula and resource for this input both exist in the database.

242 Netcool/Proviso Error Messages Guide, Version 5.2

Page 259: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10508

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

<operator name>: Error <error description> while producing tuple <tuple>

TAG

HANDLE_OUTGOING_TUPLE_ERROR

COMMENT

An error occurred while trying to process an outgoing tuple.

CAUSE

A problem in the handling code in the tech pack.

ACTION

Check for an iFix to the tech pack running on this UBA that corrects this issue.

Netcool/Proviso Error Messages Guide, Version 5.2 243

Page 260: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10509

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error <1s> while executing monitoring spec <2s>

TAG

EXECUTE_ERROR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

244 Netcool/Proviso Error Messages Guide, Version 5.2

Page 261: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10510

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Missing or unreadeable node file <xxxxxxx>

TAG

COMMENT

One input file, specified by the profile is missing.

CAUSE

Bad configuration.

ACTION

Check the file name and path, either fix the profile of the file name.

Netcool/Proviso Error Messages Guide, Version 5.2 245

Page 262: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10519

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

IP Address <xx.xx.xx.xx> rejected

TAG

REJIPADD

COMMENT

This IP address is out of range, or has been explicitely excluded within the profile.

CAUSE

Not an error.

ACTION

N/A

246 Netcool/Proviso Error Messages Guide, Version 5.2

Page 263: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10520

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Xxxxx

TAG

PINGERR

COMMENT

The ping sweep did not execute properly on the collector machine.

CAUSE

Bad configuration.

ACTION

Check qPing files permissions on the collector machine.

Netcool/Proviso Error Messages Guide, Version 5.2 247

Page 264: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10521

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Initial list of n IP adress(es), restricted to {xx,xx,xx } by command line switch

TAG

FILTERIPS

COMMENT

A subset of IP address(es) has been forced on the command line used to start the discovery. The set of IP address(es) the inventory is going to work on is the intersection between the set defined by the profile (mode 1 or 2), and the forced set. This filter usually takes place during partial re-discovery triggerred by invariant change detection mechanism.

CAUSE

Not an error.

ACTION

No action required.

248 Netcool/Proviso Error Messages Guide, Version 5.2

Page 265: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10549

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unidentified Agents = { xxxxx , xxxxx }

TAG

UNIDENTIFAGENTS

COMMENT

This is a warning message about IP addresses that have not been discovered.

CAUSE

Invalid snmp configuration, network timeouts, no SNMP agent on that box.

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 249

Page 266: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10559

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Invariant xxxxxx duplicated, causing <xxxxxxx> to be rejected

TAG

DUPELMTINV

COMMENT

An element with the same characteristics has already been discovered during this execution. The two elements have been identified as true duplicate, and second instance is ignored.

CAUSE

N/A

ACTION

N/A

250 Netcool/Proviso Error Messages Guide, Version 5.2

Page 267: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10579

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unexpected error

TAG

DISC_COMM_ERROR

COMMENT

Network related error.

CAUSE

External cause (network failure, SNMP error, communication to collector failure.

ACTION

Contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 251

Page 268: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10590

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

I/O error ’<error description>’ when writing file ’<file name>’

TAG

ERRFILE

COMMENT

Ther was an error when trying to write to a file.

CAUSE

There is a permissions problem, a file ownership problem or the disk is full.

ACTION

Check the disk utilization and the process’ permissions to access this file and directory.

252 Netcool/Proviso Error Messages Guide, Version 5.2

Page 269: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10591

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

DB_ERROR_RETRY

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 253

Page 270: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10592

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

DB_INSERT_UPDATE_FAILED

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

254 Netcool/Proviso Error Messages Guide, Version 5.2

Page 271: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10593

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

N/A

TAG

ELEMENT_MISSING

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 255

Page 272: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10594

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

RESYNC_ERROR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

256 Netcool/Proviso Error Messages Guide, Version 5.2

Page 273: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10600

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Inventory Request Failed for

TAG

RE_INVENTORY

COMMENT

Re-Inventory request failed.

CAUSE

Loss of connectivity, Discovery is not running.

ACTION

Check connectivity, system status.

Netcool/Proviso Error Messages Guide, Version 5.2 257

Page 274: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10601

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to register <application name> due to: <error details>

TAG

FAIL_VERSION_REG

COMMENT

Registering application version failed with an error.

CAUSE

Poor connectivity from CMGR to Oracle.

ACTION

Check connectivity and check Oracle status.

258 Netcool/Proviso Error Messages Guide, Version 5.2

Page 275: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10602

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to run inventory for:

TAG

RE_INVENTORY_FAILED

COMMENT

Re-Inventory request failed.

CAUSE

Wrong command line for inventory invocation, not enough privilieges to run inventory.

ACTION

Check inventory command line in log file, dc.cdf, priviliges of DataChannel user.

Netcool/Proviso Error Messages Guide, Version 5.2 259

Page 276: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10603

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unexpected line in stored QCF data: <line>

TAG

QCF_BAD_STORED_DATA

COMMENT

Bad data was encountered in the QCIF state journal files.

CAUSE

One or more of the QCIF state journal files is corrupt.

ACTION

Inspect files and/or run full 5620 dump and verify the integrity of the file system used to store QCIF’s state.

260 Netcool/Proviso Error Messages Guide, Version 5.2

Page 277: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10604

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Relation <formula name> refers to non-existent formula

TAG

INV_NO_RELATION

COMMENT

Relation specified in design file is not defined in the system.

CAUSE

N/A

ACTION

Check design file for proper relation name or add relation description (entry in FRML_DESC).

Netcool/Proviso Error Messages Guide, Version 5.2 261

Page 278: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10605

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Property <property name> refers to non-existent formula

TAG

QCF_NO_FORMULA

COMMENT

Property specified in 5620 design file is not defined in the system.

CAUSE

The 5620 system is configured to send data that the tech pack was not designed to process.

ACTION

Check design file for proper property name or add property description (entry in FRML_DESC).

262 Netcool/Proviso Error Messages Guide, Version 5.2

Page 279: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10606

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Flush aborted due to <error_description>

TAG

FLUSH_ABORT

COMMENT

A serious error occurred while saving data in the database. Flush aborted.

CAUSE

Database error or unexpected system error.

ACTION

Check database connectivity or contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 263

Page 280: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10607

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

5620 Error:

TAG

QCF_CORBA_ERROR

COMMENT

Corba exception on message send to 5620.

CAUSE

5620 failure. The application will attempt to switch to backup device and retry the operation.

ACTION

Alerts operator of potential problem with the primary device.

264 Netcool/Proviso Error Messages Guide, Version 5.2

Page 281: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10608

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Connection to <qc_server> failed due to: <error_description> -- process <process_name>

TAG

QCF_CONNECT_FAILED

COMMENT

Attemp to connect to device failed.

CAUSE

Alerts operator of potential problem with one of 5620 devices.

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 265

Page 282: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10609

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Switching from <qc_server>

TAG

QCF_BEGIN_SWITCH

COMMENT

Switching from specified device to the backup device started.

CAUSE

Attempt to recover from a QCF device failure.

ACTION

No action required.

266 Netcool/Proviso Error Messages Guide, Version 5.2

Page 283: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10610

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to reuse stored event channel reference:

TAG

QCF_INIT_WARN

COMMENT

Attempt to reuse stored QC event channel reference failed.

CAUSE

Possible cause — activity switch.

ACTION

No action required — application will create new event channel automatically.

Netcool/Proviso Error Messages Guide, Version 5.2 267

Page 284: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10611

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to reuse stored session reference:

TAG

QCF_INIT

COMMENT

Attempt to reuse stored QC session reference failed.

CAUSE

Possible cause — activity switch.

ACTION

No action required — application will create new session automatically.

268 Netcool/Proviso Error Messages Guide, Version 5.2

Page 285: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10612

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

5620 is out of sync, some events have been lost!

TAG

QCF_OUT_OF_SYNC

COMMENT

Event buffer on 5620 have been flushed, queued events are lost.

CAUSE

Event channel buffer on 5620 overflowed.

ACTION

Consider running manual full dump to resync.

Netcool/Proviso Error Messages Guide, Version 5.2 269

Page 286: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10613

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Element is not specified for

TAG

ELEMENT_NOT_SET

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

270 Netcool/Proviso Error Messages Guide, Version 5.2

Page 287: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10614

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error reading time file /file name/: /reason/

TAG

QCF_GET_OBJECT_FAILED

COMMENT

Error during QC getAttributes call.

CAUSE

Probably cause: Inventory item has been deleted.

ACTION

No action required.

Netcool/Proviso Error Messages Guide, Version 5.2 271

Page 288: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10615

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error reading Events journal file <file_name>: <reason>

TAG

QCF_CORRUPTED_JOURNAL

COMMENT

N/A

CAUSE

N/A

ACTION

No action required.

272 Netcool/Proviso Error Messages Guide, Version 5.2

Page 289: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10616

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

N/A

TAG

QCF_ITERATOR_INVALID

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 273

Page 290: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10617

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Check for primary SAM server availability

TAG

SAM_CHECK_PRIMARY

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

274 Netcool/Proviso Error Messages Guide, Version 5.2

Page 291: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10618

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Successfully switched back to primary cwm server

TAG

CWM_RESTORED_PRIMARY

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 275

Page 292: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10619

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to connect to SAM service.

TAG

SAM_PRIMARY_UNAVAILABLE

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

276 Netcool/Proviso Error Messages Guide, Version 5.2

Page 293: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10620

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Successfully switched back to primary SAM server

TAG

SAM_RESTORED_PRIMARY

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 277

Page 294: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10621

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

PROCESS_OBJECT_ERROR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

278 Netcool/Proviso Error Messages Guide, Version 5.2

Page 295: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10622

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Auto-inserted missing node at <object id>

TAG

QCF_MISSING_NODE

COMMENT

QCIF auto created a missing node in the path of a 5620 object identifier.

CAUSE

Some of the inventory 5620 inventory was not fully transferred.

ACTION

Force a full inventory dump.

Netcool/Proviso Error Messages Guide, Version 5.2 279

Page 296: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10623

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Switching from database: <db_environment>; trap server: <host>:<port>

TAG

CWM_CONNECTED

COMMENT

Switching from specified device to the backup device started.

CAUSE

Attempt to recover from a CWM connection failure.

ACTION

No action required.

280 Netcool/Proviso Error Messages Guide, Version 5.2

Page 297: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10624

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Switching from SAM SOAP service: <1s> to alternate service.

TAG

SAM_CONNECTED

COMMENT

Switching from specified device to the backup device started.

CAUSE

Attempt to recover from a SAM server connection failure.

ACTION

No action required.

Netcool/Proviso Error Messages Guide, Version 5.2 281

Page 298: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10625

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error reading time file /file name/: /reason/

TAG

QCF_GET_OID_ATTRIBUTES_FAILED

COMMENT

Error during QC getAttributes call.

CAUSE

Probably cause: Inventory item has been deleted.

ACTION

No action required.

282 Netcool/Proviso Error Messages Guide, Version 5.2

Page 299: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10626

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error reading time file /file name/: /reason/

TAG

QCF_SET_ATTRIBUTES_FAILED

COMMENT

Error during QC getAttributes call.

CAUSE

Probably cause: Inventory item has been deleted.

ACTION

No action required.

Netcool/Proviso Error Messages Guide, Version 5.2 283

Page 300: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10628

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Directory <directory> defined in dynamic library path does not exist

TAG

PATHERR

COMMENT

The directory defined in the dynamic library path is missing.

CAUSE

The directory defined in the dynamic library path is missing.

ACTION

Remove the missing directory from the dynamic library path.

284 Netcool/Proviso Error Messages Guide, Version 5.2

Page 301: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10629

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Missing MSID for: <recomputation action>

TAG

MISSING_MSID

COMMENT

RCM cannot locate the timeseries id for a recomputation action.

CAUSE

Plan is inconsistent. Perhaps a timeseries was deleted from history.

ACTION

Check plan consistency.

Netcool/Proviso Error Messages Guide, Version 5.2 285

Page 302: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10630

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

N/A

TAG

HANDLE_TUPLE_TJ

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

286 Netcool/Proviso Error Messages Guide, Version 5.2

Page 303: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10631

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Bad recomp record: <record>

TAG

BAD_RECOMP_RECORD

COMMENT

RCM has received a bad recomputation record.

CAUSE

RCM has received a bad recomputation record.

ACTION

Check input data to make sure RCM is fed recomputation records only.

Netcool/Proviso Error Messages Guide, Version 5.2 287

Page 304: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10632

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Duplicate recomp record: <record>

TAG

DUP_RECOMP

COMMENT

RCM has received a duplicate recomputation record.

CAUSE

RCM has received a duplicate recomputation record.

ACTION

Check input data to make sure RCM is not fed any duplicate recomputation records.

288 Netcool/Proviso Error Messages Guide, Version 5.2

Page 305: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10633

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

Failed to delete file: <uri> Reason: <error description>

TAG

SAM_FILE_FAILURE

COMMENT

Failed to delete SAM export file.

CAUSE

Permissions for the file prevent deletion.

ACTION

Check that the process has proper permission to delete the indicated file.

Netcool/Proviso Error Messages Guide, Version 5.2 289

Page 306: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10634

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Relation <relation name> refers to non-existent formula

TAG

INV_NO_RELATION

COMMENT

A UBA script tried to create a relation for which the relation name is not defined.

CAUSE

A tech pack has not been properly or fully installed.

ACTION

Reinstall the tech pack.

290 Netcool/Proviso Error Messages Guide, Version 5.2

Page 307: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10636

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Property <property name> refers to non-existent formula

TAG

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 291

Page 308: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10638

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

INV_NO_ELEMENT

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

292 Netcool/Proviso Error Messages Guide, Version 5.2

Page 309: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10639

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Proviso Domain Model is not configured in Ecmascript environment

TAG

INV_NO_REL_INDEX

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 293

Page 310: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10640

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

INV_NO_REL_INDEX

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

294 Netcool/Proviso Error Messages Guide, Version 5.2

Page 311: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10641

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

INV_NO_REL_NAME

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 295

Page 312: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10642

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

CONSTRAINT_VIOLATION

COMMENT

An inventory object that the UBA is being requested to create has a conflict with another inventory object already present in the system.

CAUSE

The UBA state may have been accidentally modified or deleted causing the UBA to not be synced with the DB at the proper time.

ACTION

Make sure the UBA is processing data for the most current inventory in the database that is assigned to its collector number.

296 Netcool/Proviso Error Messages Guide, Version 5.2

Page 313: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10643

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Resync time (<resync seconds>) is obsolete. Using current time (<current seconds>).

TAG

RESYNC_TIME_ERROR

COMMENT

The timestamp on a record is earlier than the current processing time of the UBA. Records should be emitted in timestamp order by the tech pack.

CAUSE

The data being fed into a UBA is not in timestamp order as expected by the tech pack or the assumptions the tech pack makes about incoming data are invalid.

ACTION

Double check the validity of data being fed into the UBA and investigate a possible tech pack bug.

Netcool/Proviso Error Messages Guide, Version 5.2 297

Page 314: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10650

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

<error detail>

TAG

FLOW_CTRL_PURGE_ERR

COMMENT

Attempt to purge files in done directory failed.

CAUSE

File access or permission problem.

ACTION

Check file permissions and user privileges.

298 Netcool/Proviso Error Messages Guide, Version 5.2

Page 315: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10701

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Collector probe to XXX failed with reason XXX

TAG

PROBE_FAILED

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 299

Page 316: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10702

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Fail over profile XXX to collector XXX

TAG

HA_FAIL_OVER

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

300 Netcool/Proviso Error Messages Guide, Version 5.2

Page 317: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10703

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Profile XXX, no available collector for failOver operation. FailOver list is XXXX

TAG

HA_NO_FAIL_OVER_AVAILABLE

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 301

Page 318: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10704

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Collector XXX is below thresholds set XXX

TAG

COLL_FAILING

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

302 Netcool/Proviso Error Messages Guide, Version 5.2

Page 319: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10705

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Lost connection to collector <host>:<port> with error: <detailed_error>

TAG

HA_LOST_CNX

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 303

Page 320: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10706

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Redundant collectors detected: XXXX

TAG

HA_REDUNDANT_COLLECTORS

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

304 Netcool/Proviso Error Messages Guide, Version 5.2

Page 321: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10707

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Collector XXX not in HA mode

TAG

HA_UNCOOPERATIVE_COLLECTOR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 305

Page 322: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10708

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to communicate with collector XXX>

TAG

HA_UNREACHABLE_COLLECTOR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

306 Netcool/Proviso Error Messages Guide, Version 5.2

Page 323: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10709

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Client host:port, error XXX when sending XXX

TAG

HA_PROTOCOL_ERROR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 307

Page 324: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10710

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Missing relation formula with id <1p>

TAG

MISSING_FORMULA

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

308 Netcool/Proviso Error Messages Guide, Version 5.2

Page 325: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10711

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Missing endpoint sub-element with id <1p> for relation <2p>, action <3p>

TAG

MISSING_RELATION_ENDPOINT

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 309

Page 326: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10712

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unknown schema: <schema name> ignoring: <file name>

TAG

UNKNOWN_SCHEMA

COMMENT

An input descriptor was encountered that is associated with an unknown input schema. The input descriptor will be ignored and discarded.

CAUSE

The configuration of the UBA was changed such that the name of an input schema was changed. A previously discovered input file is still in the system and was encountered.

ACTION

If the file needs to be processed, it may be necessary to re-stage the file in the input directory, otherwise no action is necessary and the warning was likely due to renaming an input schema.

310 Netcool/Proviso Error Messages Guide, Version 5.2

Page 327: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10751

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Probing Statuses for collectors: XXX

TAG

HA_PROBING_COLLECTORS

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 311

Page 328: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10752

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Results per collector: XXX

TAG

HA_PROBE_RESULT_COLLECTOR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

312 Netcool/Proviso Error Messages Guide, Version 5.2

Page 329: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10753

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Results per profile: XXX

TAG

HA_PROBE_RESULT_PROFILE

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 313

Page 330: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10754

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Starting profile XXX on collector XXX

TAG

HA_STARTING_COLLECTOR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

314 Netcool/Proviso Error Messages Guide, Version 5.2

Page 331: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10755

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Stopping collector XXX (was assigned to profile XXX)

TAG

HA_STOPPING_COLLECTOR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 315

Page 332: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10756

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Preloading configuration XXX on collector XXX with timeout XXX

TAG

HA_PRELOADING_COLLECTOR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

316 Netcool/Proviso Error Messages Guide, Version 5.2

Page 333: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10757

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Extending timeout by XXX for collector XXX

TAG

HA_EXTENDING_COLLECTOR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 317

Page 334: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10758

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Disabling expiration for collector XXX

TAG

HA_DISABLING_EXPIRATION

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

318 Netcool/Proviso Error Messages Guide, Version 5.2

Page 335: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10759

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Re-registering collector <1s> as active for profile <2s>

TAG

HA_REREGISTER_COLLECTOR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 319

Page 336: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10760

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Pausing collector XXX (assigned to profile XXX)

TAG

HA_PAUSING_COLLECTOR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

320 Netcool/Proviso Error Messages Guide, Version 5.2

Page 337: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10800

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Received trap number {n}, but was expecting {m}

TAG

RTM_UNEXPECTED_SEQUENCE_NUMBER

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 321

Page 338: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10801

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to recover <1p> traps (<2p>-<3p>)

TAG

RTM_UNRECOVERABLE_TRAPS

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

322 Netcool/Proviso Error Messages Guide, Version 5.2

Page 339: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10802

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to get sysUpTime from RTM Service Agent at <host><port>

TAG

RTM_GET_SYSUPTIME_FAILED

COMMENT

Failed to get sysUpTime from RTM Service Agent.

CAUSE

Communications failure, RTM agent down.

ACTION

Check communications, RTM server.

Netcool/Proviso Error Messages Guide, Version 5.2 323

Page 340: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10803

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

N/A

TAG

RTM_AGENT_ACCESS_FAILURE

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

324 Netcool/Proviso Error Messages Guide, Version 5.2

Page 341: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10804

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

Missing configuration for CWM connections.

TAG

CWM_CONFIG_ERROR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 325

Page 342: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10805

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

N/A

TAG

CWM_MODEL_FILE_MISSING

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

326 Netcool/Proviso Error Messages Guide, Version 5.2

Page 343: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10806

COMPONENT

DataChannel

TYPE

Fatal

MESSAGE

N/A

TAG

PERF_DOWNLOAD

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 327

Page 344: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10807

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

IGNORE_DELETE

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

328 Netcool/Proviso Error Messages Guide, Version 5.2

Page 345: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10808

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error processing trap <1p> due to <2s>

TAG

PREPROCESS_TRAP_ERROR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 329

Page 346: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10809

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error renewing registration with service agent <1s>:<2p> - <3s>

TAG

REGISTRATION_RENEWAL_ERROR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

330 Netcool/Proviso Error Messages Guide, Version 5.2

Page 347: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10810

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Process trap <1p>, sn=<2p>, ts=<3p> for <4s>(<5s>)

TAG

NO_ENDPOINT

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 331

Page 348: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10811

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Element is not specified for

TAG

ELEMENT_NOT_SET

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

332 Netcool/Proviso Error Messages Guide, Version 5.2

Page 349: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10850

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Registering with RTM Service Agent at {host}:{port}

TAG

RTM_REGISTERING

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 333

Page 350: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10851

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Unregistering with RTM Service Agent at {host}:{port}

TAG

RTM_UNREGISTERING

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

334 Netcool/Proviso Error Messages Guide, Version 5.2

Page 351: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10852

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

Renewing registration with RTM Service Agent at <1p>:<2p>

TAG

RTM_RENEWING_REGISTRATION

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 335

Page 352: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10853

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

Received trap <trap pdu>

TAG

RTM_TRAP_RECEIVED

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

336 Netcool/Proviso Error Messages Guide, Version 5.2

Page 353: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10854

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Starting resync with RTM Service Agent at {host}:{port}

TAG

RTM_STARTING_RESYNC

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 337

Page 354: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10855

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Recovered trap number <1p> from RTM Service Agent at <2p>:<3p>, proceeding with recovery

TAG

RTM_RESYNCING

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

338 Netcool/Proviso Error Messages Guide, Version 5.2

Page 355: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10856

COMPONENT

DataChannel

TYPE

Debug

MESSAGE

Received response: <pdu>

TAG

RTM_RECEIVED_RESPONSE

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 339

Page 356: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10857

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Starting SNMP listener on port: {port}

TAG

RTM_STARTING_LISTENER

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

340 Netcool/Proviso Error Messages Guide, Version 5.2

Page 357: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10858

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Starting RTM registration renewal job

TAG

RTM_STARTING_RENEWAL_JOB

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 341

Page 358: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10859

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Stopping RTM registration renewal job

TAG

RTM_STOPPING_RENEWAL_JOB

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

342 Netcool/Proviso Error Messages Guide, Version 5.2

Page 359: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10860

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Stopping SNMP listener on port: {port}

TAG

RTM_STOPPING_LISTENER

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 343

Page 360: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10861

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Starting Glorp session for database <1s>, user: <2s>

TAG

CWM_INFORMIX_LOGIN_SUCCESSFUL

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

344 Netcool/Proviso Error Messages Guide, Version 5.2

Page 361: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10862

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to connect to cwm trap server

TAG

CWM_SNMP_CONNECTION_FAILURE

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 345

Page 362: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10863

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Incoming RTM trap number (<trap number>) is smaller than the last received (<last trap number>), resetting to 0

TAG

RTM_RESET_SEQUENCE

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

346 Netcool/Proviso Error Messages Guide, Version 5.2

Page 363: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10864

COMPONENT

DataChannel

TYPE

Informational

MESSAGE

Renewing registration with RTM Service Agent at {host}:{port}

TAG

RTM_RENEWAL_SUCCEEDED

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 347

Page 364: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10865

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Renewing registration with RTM Service Agent at {host}:{port}

TAG

RTM_RENEWAL_FAILED

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

348 Netcool/Proviso Error Messages Guide, Version 5.2

Page 365: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10866

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to connect to cwm trap server

TAG

CWM_SNMP_CONNECTION_FAILURE

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 349

Page 366: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10900

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

BAD_CONFIG

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

350 Netcool/Proviso Error Messages Guide, Version 5.2

Page 367: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10901

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error: <error detail>

TAG

FORMULA_LINK_ERROR

COMMENT

An error has occurred during the linking of formula dependencies.

CAUSE

Code defect.

ACTION

Contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 351

Page 368: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10902

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Bad PDU received <error description>

TAG

PDU

COMMENT

A bad PDU was received.

CAUSE

Another system sent a malformed message.

ACTION

Verify the correct operation of other systems with which the affected component is communicating.

352 Netcool/Proviso Error Messages Guide, Version 5.2

Page 369: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10903

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

MIBS_ERROR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 353

Page 370: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10904

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

N/A

TAG

CMD_ERROR

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

354 Netcool/Proviso Error Messages Guide, Version 5.2

Page 371: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

10905

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to adapt <object_name> (<object_type>)

TAG

ADAPT_FAILURE

COMMENT

There was an error in trying to emit either an element or a sub-element created by a tech pack.

CAUSE

It can be caused by either a problem with the data being fed to the UBA or a bug in the tech pack code.

ACTION

Verify that the input data is correct. Contact your system administrator or technical Support if the input data looks correct and you are unable to resolve the issue.

Netcool/Proviso Error Messages Guide, Version 5.2 355

Page 372: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

11016

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Attempt to inject tuples, but one or more files is missing or in the wrong location: <file name>

TAG

TUPLE_INJECT_FAILURE

COMMENT

An attempt was made to inject tuples with a tuple container that has missing or invalid files.

CAUSE

A tuple storage client is not behaving correctly.

ACTION

Contact your Proviso system administrator.

356 Netcool/Proviso Error Messages Guide, Version 5.2

Page 373: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

11017

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to acquire tuples (label: <1s> time: <2s> reason: <3s>)

TAG

FAILED_ACQUIRING_TUPLES

COMMENT

Failed to acquire files from an up stream component.

CAUSE

The files in the upstream component’s output directory are missing or otherwise inaccessible.

ACTION

Double check that the process can access the output directory of the up stream component over the file system, ftp or stfp (depending on the system configuration).

Netcool/Proviso Error Messages Guide, Version 5.2 357

Page 374: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

11018

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Name server (CNS) lookup failed for node <node_name>

TAG

TUPLE_COMM_FAILURE

COMMENT

An attempt to lookup a tuple communications node failed.

CAUSE

The name server (CNS) or the component hosting the node (a CME or FTE) is not running.

ACTION

Make sure the CNS, FTEs and CMEs are running.

358 Netcool/Proviso Error Messages Guide, Version 5.2

Page 375: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

11019

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

A communcations error occurred with node <node_name>: <error_description>

TAG

TUPLE_COMM_FAILURE

COMMENT

An attempt to communicate with a tuple node failed.

CAUSE

The component hosting the node (a CME or FTE) is not running.

ACTION

Make sure the FTEs and CMEs are running and check their logs for any warning or fatal messages.

Netcool/Proviso Error Messages Guide, Version 5.2 359

Page 376: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

12347

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Error in FormulaOperator>>update:with: as a result of responding to <symbol> notification.

TAG

ERROR

COMMENT

An error occured while handling internal event notification.

CAUSE

Unknown error.

ACTION

Contact IBM Technical Support.

360 Netcool/Proviso Error Messages Guide, Version 5.2

Page 377: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

12349

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Something is wrong with inputs: <inputs>. Expected it to be sized <arguments size>

TAG

MALFORMED_INPUTS

COMMENT

Something is wrong with the number of inputs because it does not match what was expected based on the formula.

CAUSE

Something is wrong with the number of inputs because it does not match what was expected based on the formula.

ACTION

Check the formula arguments to make sure they are valid properties/formulas/calendars.

Netcool/Proviso Error Messages Guide, Version 5.2 361

Page 378: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

12350

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Operator <operator id> input for argument : <argument> is missing (most probably sub-element does not have proper relation)

TAG

MISSING_INPUT

COMMENT

The formula specifies an argument but there is no input for that argument which means the sub-element could be missing an expected relation, property or calendar.

CAUSE

Subelement could be missing an expected relation, property or calendar.

ACTION

Check that the necessary relations, properties and calendars exist.

362 Netcool/Proviso Error Messages Guide, Version 5.2

Page 379: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

12351

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Can’t build input for argument <argument> for <operator id> because formula <formula> is missing

TAG

MISSING_INPUT

COMMENT

Unable to build input because argument formula is missing.

CAUSE

Argument formula is missing.

ACTION

Check to see if argument formula was deleted manually.

Netcool/Proviso Error Messages Guide, Version 5.2 363

Page 380: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

12352

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed while contacting the plan builder to see if a resync is required for <label> : <error>

TAG

WARNING

COMMENT

CME has failed to contact the PBL to see if there are plan changes within the current hour. CME contacting PBL is an optimization. Since it failed, CME will simply do a database resync of plan changes for the current hour.

CAUSE

PBL might be stopped or unresponsive.

ACTION

Check PBL and make sure it is running well.

364 Netcool/Proviso Error Messages Guide, Version 5.2

Page 381: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

12356

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed to recover pending xlog command: <error description>

TAG

RECOVERY_ABORTED

COMMENT

Pending xlog commands are replayed on restart to complete transactions. A failure occured during this replay.

CAUSE

Database or other resource could be unavailable.

ACTION

Review the error description and ensure necessary resources like the database are available. Contact Support.

Netcool/Proviso Error Messages Guide, Version 5.2 365

Page 382: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

12357

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

<problem description> for [<metric description>]

TAG

INVALID_METRIC

COMMENT

An attempt was made to create a metric with invalid state.

CAUSE

The metric was created without a valid metric id, resource, timestamp, value or collector number.

ACTION

Verify the data being fed to the UBA for accuracy and check the tech pack script for bugs.

366 Netcool/Proviso Error Messages Guide, Version 5.2

Page 383: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

12358

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Unable to produce a record because there is no adaptor to process it

TAG

MISSING_ADAPTOR

COMMENT

There is no adaptor to handle metric records that are emitted by the script.

CAUSE

A misconfiguration or an error in the script is the most likely cause.

ACTION

Double check the UBA settings and the script. Make sure the correct version of the tech pack script is configured. Check for any iFixes for the tech pack that would correct the issue.

Netcool/Proviso Error Messages Guide, Version 5.2 367

Page 384: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

12360

COMPONENT

DataChannel

TYPE

Warning

MESSAGE

Failed while contacting the plan builder: <error description>

TAG

WARNING

COMMENT

The UBA failed to contact the plan builder while trying to inform it about unexpected metrics that it is seeing.

CAUSE

A general communications issue.

ACTION

Check network connectivity and make sure the channel management components are running.

368 Netcool/Proviso Error Messages Guide, Version 5.2

Page 385: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

39001

COMPONENT

DataLoad

TYPE

Warning

MESSAGE

N/A

TAG

PROFILENOTPROGRESSING

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

Netcool/Proviso Error Messages Guide, Version 5.2 369

Page 386: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

39002

COMPONENT

DataLoad

TYPE

Debug

MESSAGE

Full inventory dump is being retried due to the following reason: <problem description>)

TAG

FULL_DUMP_RETRIED

COMMENT

A full dump of inventory objects had an error and is being retried.

CAUSE

A communications interruption with the server.

ACTION

Initiate another full dump.

370 Netcool/Proviso Error Messages Guide, Version 5.2

Page 387: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

39201

COMPONENT

DataLoad

TYPE

Informational

MESSAGE

Record #<record_number> rejected because: <error_msg>

TAG

RECORD_REJECTED

COMMENT

An error was encountered during record processing. The specific error is reported in the log message. This message does not necessarily indicate a problem.

CAUSE

There can be many causes and this message does not necessarily indicate a problem.

ACTION

Investigate the reason for the error to determine whether or not it’s a normal condition or a legitimate problem.

Netcool/Proviso Error Messages Guide, Version 5.2 371

Page 388: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

39205

COMPONENT

DataLoad

TYPE

Warning

MESSAGE

Unknown timezone: <string>

TAG

UNKNOWN_TIME_ZONE

COMMENT

The configured timezone could not be found in the zoneinfo (tz) database.

CAUSE

The TIMEZONE setting does not match anything in the zoneinfo (tz) database on the host where the UBA is running.

ACTION

Double check the TIMEZONE configuration setting and verify that it is in the zoneinfo (tz) database on the host where the UBA is running and change the configuration as necessary.

372 Netcool/Proviso Error Messages Guide, Version 5.2

Page 389: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

39206

COMPONENT

DataLoad

TYPE

Warning

MESSAGE

License(<license_name>) is invalid or missing

TAG

INVALID_LICENSE

COMMENT

The shared library that the UBA uses for ODBC connectivity does not have correct OEM licensing information.

CAUSE

The ODBC library may have been obtained from some source other than IBM or is otherwise misconfigured. The OEM licensing information is embedded inside the shared library when it is prepared for distribution with the TNPM product, hence, only the IBM supplied shared library for ODBC connectivity will work with the TNPM product.

ACTION

Contact IBM Technical Support.

Netcool/Proviso Error Messages Guide, Version 5.2 373

Page 390: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

39207

COMPONENT

DataLoad

TYPE

Debug

MESSAGE

Timezone requested: <1s>, used: <2s>

TAG

TIME_ZONE_USED

COMMENT

N/A

CAUSE

N/A

ACTION

N/A

374 Netcool/Proviso Error Messages Guide, Version 5.2

Page 391: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

39208

COMPONENT

DataLoad

TYPE

Warning

MESSAGE

No Adaptors deployed

TAG

NO_ADAPTORS_DEPLOYED

COMMENT

No adaptors were specified in the design file (or no design file was found).

CAUSE

The DESIGNFILE or INSTANCES settings in the configuration file are missing or incorrect.

ACTION

Double check DESIGNFILE and INSTANCES settings in the configuration file.

Netcool/Proviso Error Messages Guide, Version 5.2 375

Page 392: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

39209

COMPONENT

DataLoad

TYPE

Warning

MESSAGE

No availability files found for metric file <file name>

TAG

MISSING_AVAILABILITY_FILES

COMMENT

The output directory or tuple storage queue contains more than the maximum allowed number of hours of data waiting to be picked up by a downstream component.

376 Netcool/Proviso Error Messages Guide, Version 5.2

Page 393: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

Netcool/Proviso Error Messages Guide, Version 5.2 377

Page 394: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Chapter 1: Netcool/Proviso Log Messages

378 Netcool/Proviso Error Messages Guide, Version 5.2

Page 395: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Notices

This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information about the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user’s responsibility to evaluate and verify the operation of any non-IBM product, program, or service.

IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to:

IBM Director of Licensing IBM Corporation North Castle Drive Armonk, NY 10504-1785 U.S.A.

For license inquiries regarding double-byte (DBCS) information, contact the IBM Intellectual Property Department in your country or send inquiries, in writing, to:

Intellectual Property Licensing Legal and Intellectual Property Law IBM Japan Ltd. 1623-14, Shimotsuruma, Yamato-shi Kanagawa 242-8502 Japan.

The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law:

INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement might not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.

Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk.

IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.

Licensees of this program who wish to have information about it for the purpose of enabling: (i) the exchange of information between independently created programs and other programs (including this one) and (ii) the mutual use of the information which has been exchanged, should contact:

IBM Corporation 2Z4A/101 11400 Burnet Road Austin, TX 78758 U.S.A.

Such information may be available, subject to appropriate terms and conditions, including in some cases payment of a fee.

The licensed program described in this document and all licensed material available for it are provided by IBM under terms of the IBM Customer Agreement, IBM International Program License Agreement or any equivalent agreement between us.

Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally

Page 396: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

available systems. Furthermore, some measurement may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.

Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products.

All statements regarding IBM’s future direction or intent are subject to change or withdrawal without notice, and represent goals and objectives only.

This information is for planning purposes only. The information herein is subject to change before the products described become available.

This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names

and addresses used by an actual business enterprise is entirely coincidental.

COPYRIGHT LICENSE:

This information contains sample application programs in source language, which illustrate programming techniques on various operating systems. You may copy, modify, and distribute these sample programs in any form without payment to IBM, for the purposes of developing, using, marketing or distributing application programs conforming to the application programming interface for the operating system for which the sample programs are written. These examples have not been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or imply reliability, serviceability, or function of these programs. You may copy, modify, and distribute these sample programs in any form without payment to IBM for the purposes of developing, using, marketing, or distributing application programs conforming to IBM's application programming interfaces.

If you are viewing this information in softcopy form, the photographs and color illustrations might not appear.

Trademarks

IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at “Copyright and trademark information” at www.ibm.com/legal/copytrade.shtml.

Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States, other countries, or both.

Linux is a trademark of Linus Torvalds in the United States, other countries, or both.

Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States, other countries, or both.

UNIX is a registered trademark of The Open Group in the United States and other countries.

Other product, and service names may be trademarks or service marks of others.

Java and all Java-based trademarks and logos are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.

Page 397: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Additional Copyright Information

The following copyright information is for software used by Netcool/Proviso.

Tcl 8.3.3, Combat/TCL 0.7.3, Combat/TCL 0.7.5, TclX 8.3, TK 8.3.3

This software is copyrighted by the Regents of the University of California, Sun Microsystems, Inc., Scriptics Corporation, and other parties. The following terms apply to all files associated with the software unless explicitly disclaimed in individual files.

The authors hereby grant permission to use, copy, modify, distribute, and license this software and its documentation for any purpose, provided that existing copyright notices are retained in all copies and that this notice is included verbatim in any distributions. No written agreement, license, or royalty fee is required for any of the authorized uses. Modifications to this software may be copyrighted by their authors and need not follow the licensing terms described here, provided that the new terms are clearly indicated on the first page of each file where they apply.

IN NO EVENT SHALL THE AUTHORS OR DISTRIBUTORS BE LIABLE TO ANY PARTY FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS SOFTWARE, ITS DOCUMENTATION, OR ANY DERIVATIVES THEREOF, EVEN IF THE AUTHORS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

THE AUTHORS AND DISTRIBUTORS SPECIFICALLY DISCLAIM ANY WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT. THIS SOFTWARE IS PROVIDED ON AN "AS IS" BASIS, AND THE AUTHORS AND DISTRIBUTORS HAVE NO OBLIGATION TO PROVIDE MAINTENANCE, SUPPORT, UPDATES, ENHANCEMENTS, OR MODIFICATIONS.

GOVERNMENT USE: If you are acquiring this software on behalf of the U.S. government, the Government shall have only "Restricted Rights" in the software and related documentation as defined in the Federal Acquisition Regulations (FARs) in Clause 52.227.19 (c) (2). If you are acquiring the software on behalf of the Department of Defense, the software shall be classified as "Commercial Computer Software" and the Government shall have only "Restricted Rights" as defined in Clause 252.227-7013 (c) (1) of DFARs. Notwithstanding the foregoing, the authors grant the U.S. Government and others acting in its behalf permission to use and distribute the software in accordance with the terms specified in this license.

SCOTTY Stack

This software is copyrighted by Juergen Schoenwaelder, the Technical University of Braunschweig, the University of Twente, and other parties. The following terms apply to all files associated with the software unless explicitly disclaimed in individual files.

The authors hereby grant permission to use, copy, modify, distribute, and license this software and its documentation for any purpose, provided that existing copyright notices are retained in all copies and that this notice is included verbatim in any distributions. No written agreement, license, or royalty fee is required for any of the authorized uses. Modifications to this software may be copyrighted by their authors and need not follow the licensing terms described here, provided that the new terms are clearly indicated on the first page of each file where they apply.

IN NO EVENT SHALL THE AUTHORS OR DISTRIBUTORS BE LIABLE TO ANY PARTY FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS SOFTWARE, ITS DOCUMENTATION, OR ANY DERIVATIVES THEREOF, EVEN IF THE AUTHORS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

THE AUTHORS AND DISTRIBUTORS SPECIFICALLY DISCLAIM ANY WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT. THIS SOFTWARE IS PROVIDED ON AN “AS IS” BASIS, AND THE AUTHORS AND DISTRIBUTORS HAVE NO OBLIGATION TO PROVIDE MAINTENANCE, SUPPORT, UPDATES, ENHANCEMENTS, OR MODIFICATIONS.

Netcool/Proviso Error Messages Guide, Version 5.2 381

Page 398: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Various copyrights apply to this package, listed in 3 separate parts below. Please make sure that you include all the parts. Up until 2001, the project was based at UC Davis, and the first part covers all code written during this time. From 2001 onwards, the project has been based at SourceForge, and Networks Associates Technology, Inc hold the copyright on behalf of the wider Net-SNMP community, covering all derivative work done since then. An additional copyright section has been added as Part 3 below also under a BSD license for the work contributed by Cambridge Broadband Ltd. to the project since 2001.

Part 1: CMU/UCD copyright notice: (BSD like)

Copyright © 1989, 1991, 1992 by Carnegie Mellon University

Derivative Work - 1996, 1998-2000

Copyright © 1996, 1998-2000 The Regents of the University of California

All Rights Reserved

Permission to use, copy, modify and distribute this software and its documentation for any purpose and without fee is hereby granted, provided that the above copyright notice appears in all copies and that both that copyright notice and this permission notice appear in supporting documentation, and that the name of CMU and The Regents of the University of California not be used in advertising or publicity pertaining to distribution of the software without specific written permission.

CMU AND THE REGENTS OF THE UNIVERSITY OF CALIFORNIA DISCLAIM ALL WARRANTIES WITH REGARD TO THIS SOFTWARE, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL CMU OR THE REGENTS OF THE UNIVERSITY OF CALIFORNIA BE LIABLE FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM THE LOSS OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE.

Part 2: Networks Associates Technology, Inc copyright notice (BSD)

Copyright © 2001, Networks Associates Technology, Inc

All rights reserved.

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

• Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.• Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer

in the documentation and/or other materials provided with the distribution.• Neither the name of the NAI Labs nor the names of its contributors may be used to endorse or promote products derived

from this software without specific prior written permission.THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

Part 3: Cambridge Broadband Ltd. copyright notice (BSD)

Portions of this code are copyright © 2001, Cambridge Broadband Ltd.

All rights reserved.

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

• Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.• Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer

in the documentation and/or other materials provided with the distribution.• The name of Cambridge Broadband Ltd. may not be used to endorse or promote products derived from this software without

specific prior written permission.

382 Netcool/Proviso Error Messages Guide, Version 5.2

Page 399: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

BLT 2.4u

Portions (c) 1993 AT&T, (c) 1993 - 1998 Lucent Technologies, (c) 1994-1998 Sun Microsystems, Inc., and (c) 1987-1993 The Regents of the University of California.

Permission to use, copy, modify and distribute this software and its documentation for any purpose and without fee is hereby granted, provided that the above copyright notice appears in all copies and that both that copyright notice and this permission notice appear in supporting documentation, and that the names of AT&T, Lucent Technologies Inc., Sun Microsystems, Inc. and The Regents of the University of California not be used in advertising or publicity pertaining to distribution of the software without specific written permission.

THE COPYRIGHT HOLDERS AND OTHER CONTRIBUTORS DISCLAIM ALL WARRANTIES WITH REGARD TO THIS SOFTWARE, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL THE COPYRIGHT HOLDERS OR OTHER CONTRIBUTORS BE LIABLE FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM THE LOSS OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE.

CMU-SNMP 1.14

CMU/UCD copyright notice: (BSD like) Copyright 1989, 1991, 1992 by Carnegie Mellon University

Derivative Work - 1996, 1998-2000 Copyright 1996, 1998-2000 The Regents of the University of California

All Rights Reserved

Permission to use, copy, modify and distribute this software and its documentation for any purpose and without fee is hereby granted, provided that the above copyright notice appears in all copies and that both that copyright notice and this permission notice appear in supporting documentation, and that the name of CMU and The Regents of the University of California not be used in advertising or publicity pertaining to distribution of the software without specific written permission.

CMU AND THE REGENTS OF THE UNIVERSITY OF CALIFORNIA DISCLAIM ALL WARRANTIES WITH REGARD TO THIS SOFTWARE, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL CMU OR THE REGENTS OF THE UNIVERSITY OF CALIFORNIA BE LIABLE FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM THE LOSS OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE.

Scotty 2.8, incrTCL 3.0, [incr TCL] 3.2

Portions Copyright (c) 1987-1994 The Regents of the University of California. Copyright (c) 1994-1995 Sun Microsystems, Inc.

This software is copyrighted by the Regents of the University of California, Sun Microsystems, Inc., and other parties. The following terms apply to all files associated with the software unless explicitly disclaimed in individual files.

Netcool/Proviso Error Messages Guide, Version 5.2 383

Page 400: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

The authors hereby grant permission to use, copy, modify, distribute, and license this software and its documentation for any purpose, provided that existing copyright notices are retained in all copies and that this notice is included verbatim in any distributions. No written agreement, license, or royalty fee is required for any of the authorized uses. Modifications to this software may be copyrighted by their authors and need not follow the licensing terms described here, provided that the new terms are clearly indicated on the first page of each file where they apply.

IN NO EVENT SHALL THE AUTHORS OR DISTRIBUTORS BE LIABLE TO ANY PARTY FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS SOFTWARE, ITS DOCUMENTATION, OR ANY DERIVATIVES THEREOF, EVEN IF THE AUTHORS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

THE AUTHORS AND DISTRIBUTORS SPECIFICALLY DISCLAIM ANY WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT. THIS SOFTWARE IS PROVIDED ON AN "AS IS" BASIS, AND THE AUTHORS AND DISTRIBUTORS HAVE NO OBLIGATION TO PROVIDE MAINTENANCE, SUPPORT, UPDATES, ENHANCEMENTS, OR MODIFICATIONS.

RESTRICTED RIGHTS: Use, duplication or disclosure by the government is subject to the restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software Clause as DFARS 252.227-7013 and FAR 52.227-19.

Portions Copyright (c) 1993-1998 Lucent Technologies, Inc.

Permission to use, copy, modify, and distribute this software and its documentation for any purpose and without fee is hereby granted, provided that the above copyright notice appear in all copies and that both that the copyright notice and warranty disclaimer appear in supporting documentation, and that the names of Lucent Technologies any of their entities not be used in advertising or publicity pertaining to distribution of the software without specific, written prior permission.

Lucent disclaims all warranties with regard to this software, including all implied warranties of merchantability and fitness. In no event shall Lucent be liable for any special, indirect or consequential damages or any damages whatsoever resulting from loss of use, data or profits, whether in an action of contract, negligence or other tortuous action, arising out of or in connection with the use or performance of this software.

UCD SNMP 4.2.5

Portions Copyright 1989, 1991, 1992 by Carnegie Mellon University. Derivative Work - 1996, 1998-2000, Copyright 1996, 1998-2000 The Regents of the University of California All Rights Reserved

Permission to use, copy, modify and distribute this software and its documentation for any purpose and without fee is hereby granted, provided that the above copyright notice appears in all copies and that both that copyright notice and this permission notice appear in supporting documentation, and that the name of CMU and The Regents of the University of California not be used in advertising or publicity pertaining to distribution of the software without specific written permission.

CMU AND THE REGENTS OF THE UNIVERSITY OF CALIFORNIA DISCLAIM ALL WARRANTIES WITH REGARD TO THIS SOFTWARE, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL CMU OR THE REGENTS OF THE UNIVERSITY OF CALIFORNIA BE LIABLE FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM THE LOSS OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE.

Portions Copyright: (c) 2001-2003, Networks Associates Technology, Inc, (c) 2001-2003, Cambridge Broadband Ltd, (c) 2003-2005, Sparta, Inc., (c) 2004, Cisco, Inc and Information Network Center of Beijing University of Posts and Telecommunications, (c) Fabasoft R&D Software GmbH & Co KG, 2003 [email protected]. All rights reserved.

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.

3. Neither the names of Networks Associates Technology, Inc, Cambridge Broadband Ltd., Sparta, Inc., Cisco, Inc, Beijing University of Posts and Telecommunications, Fabasoft R&D Software GmbH & Co KG or any of its subsidiaries, brand or product

384 Netcool/Proviso Error Messages Guide, Version 5.2

Page 401: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

names, nor the names of their contributors may be used to endorse or promote products derived from this software without specific prior written permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

JDOM 1.0

Copyright (C) 2000-2004 Jason Hunter & Brett McLaughlin. All rights reserved.

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

1. Redistributions of source code must retain the above copyright notice, this list of conditions, and the following disclaimer.

2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions, and the disclaimer that follows these conditions in the documentation and/or other materials provided with the distribution.

3. The name "JDOM" must not be used to endorse or promote products derived from this software without prior written permission. For written permission, please contact <request_AT_jdom_DOT_org>.

4. Products derived from this software may not be called "JDOM", nor may "JDOM" appear in their name, without prior written permission from the JDOM Project Management <request_AT_jdom_DOT_org>.

In addition, we request (but do not require) that you include in the end-user documentation provided with the redistribution and/or in the software itself an acknowledgement equivalent to the following:

"This product includes software developed by the JDOM Project (http://www.jdom.org/)." Alternatively, the acknowledgment may be graphical using the logos available at http://www.jdom.org/images/logos.

THIS SOFTWARE IS PROVIDED ``AS IS'' AND ANY EXPRESSED OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE JDOM AUTHORS OR THE PROJECT CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

This software consists of voluntary contributions made by many individuals on behalf of the JDOM Project and was originally created by Jason Hunter <jhunter_AT_jdom_DOT_org> and Brett McLaughlin <brett_AT_jdom_DOT_org>. For more information on the JDOM Project, please see <http://www.jdom.org/>.

Regex 1.1a

Copyright (C) 1996, 1999 Vassili Bykov. It is provided to the Smalltalk community in hope it will be useful.

1. This license applies to the package as a whole, as well as to any component of it. By performing any of the activities described below, you accept the terms of this agreement.

2. The software is provided free of charge, and ``as is'', in hope that it will be useful, with ABSOLUTELY NO WARRANTY. The entire risk and all responsibility for the use of the software is with you. Under no circumstances the author may be held responsible

Netcool/Proviso Error Messages Guide, Version 5.2 385

Page 402: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

for loss of data, loss of profit, or any other damage resulting directly or indirectly from the use of the software, even if the damage is caused by defects in the software.

3. You may use this software in any applications you build.

4. You may distribute this software provided that the software documentation and copyright notices are included and intact.

5. You may create and distribute modified versions of the software, such as ports to other Smalltalk dialects or derived work, provided that:

a. any modified version is expressly marked as such and is not misrepresented as the original software;

b. credit is given to the original software in the source code and documentation of the derived work;

c. the copyright notice at the top of this document accompanies copyright notices of any modified version.

386 Netcool/Proviso Error Messages Guide, Version 5.2

Page 403: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

387 Netcool/Proviso dbMgr Reference Guide, Version 5.2

Page 404: Tivoli Netcool Performance Manager 1.3 IBM Wireline Component … · Netcool/Proviso Error Messages Guide, Version 5.2 xv Preface IBM® Tivoli® Netcool® Performance Manager 1.3

Printed in the USA.

IBM®