    System x3650 M5Lenovo Press Product Guide

    Withthepowerful,versatilenew2Utwo-socketSystemx3650M5rackserver,youcanrunevenmoreworkloads,24x7,andgainfasterbusinessinsights.IntegratedwithIntelXeonprocessorE5-2600v3productfamilyandindustry-leadingtwo-socketstoragecapacity,thex3650M5fastforwardsyourbusiness.Youcanselectfromanimpressivearrayofstorageconfigurations(upto26drivebays)thatoptimizediverseworkloadsfromcloudtobigdata.

    Suggesteduses:Database,cloudcomputingandvirtualization,enterpriseapplications,collaboration/email,businessanalyticsandbigdata,andMicrosoftRemoteFXapplications.

    Figure1showstheSystemx3650M5.

    Figure1.TheSystemx3650M5

    Did you know?

    Thex3650M5incorporatesenergy-smartfeaturesforminimizedcostsandefficientperformance.Dualfanzonessupportoperationinupto40Cenvironments.The80PLUSTitaniumpowersupplyunits(PSUs)candeliver96%efficiencyat50%load.

    Thex3650M5hasoutstandingmemoryperformancethatisachievedbysupportingtwo-RDIMMs-per-channelconfigurationsatspeedsupto12%fasterthantheIntelspecification,whilestillmaintainingworld-classreliability.

    Systemxserversachievedthehighestreliabilityofanyx86servers;seeITIC2014-2015GlobalServerHardware,ServerOSReliabilitySurvey:http://public.dhe.ibm.com/common/ssi/ecm/en/xsl03126usen/XSL03126USEN.PDF

    Thex3650M5integratesleadershipsecurityandreliability.SystemxTrustedPlatformAssurance,anexclusivesetofSystemxfeaturesandpractices,establishesafoolproofsecurityfoundationforyourworkloads.Enterprise-classdataprotectionisprovidedwithoptionalself-encryptingdrivesandsimple,centralizedkeymanagementthroughIBMSecurityKeyLifecycleManagement.Diagnostictoolsfacilitatereduceddowntimeandcosts.

    http://public.dhe.ibm.com/common/ssi/ecm/en/xsl03126usen/XSL03126USEN.PDFhttp://public.dhe.ibm.com/common/ssi/ecm/en/xsl03126usen/XSL03126USEN.PDF
  • 7/26/2019 Tips 1193

    2/64

    Systemx3650M5 2

    Key features

    Thex3650M5isaversatile2Utwo-socketbusiness-criticalserverthatoffersimprovedperformanceandpay-as-you-growflexibilityalongwithnewfeaturesthatimproveservermanagementcapability.Thispowerfulsystemisdesignedforyourmostimportantbusinessapplicationsandclouddeployments.

    Combiningbalancedperformanceandflexibility,thex3650M5isagreatchoiceforsmallandmediumbusinessesuptothelargeenterprise.Itcanprovideoutstandinguptimetokeepbusiness-criticalapplicationsandclouddeploymentsrunningsafely.Easeofuseandcomprehensivesystemsmanagementtoolshelpmakedeploymenteasier.Outstandingreliability,availability,andserviceability(RAS)andhigh-efficiencydesignimproveyourbusinessenvironmentandhelpsaveoperationalcosts.

    Scalabi l i ty and performance

    Thex3650M5offersnumerousfeaturestoboostperformance,improvescalability,andreducecosts:

    Improvesproductivitybyofferingsuperiorsystemperformancewithupto18-coreprocessors,upto45MBofL3cache,andupto9.6GT/sQPIinterconnectlinks.

    Supportsuptotwoprocessors,36cores,and72threadsmaximizetheconcurrentexecutionof

    multi-threadedapplications.

    IntelligentandadaptivesystemperformancewithenergyefficientIntelTurboBoostTechnologyallowsCPUcorestorunatmaximumspeedsduringpeakworkloadsbytemporarilygoingbeyondprocessorthermaldesignpower(TDP).

    IntelHyper-ThreadingTechnologyboostsperformanceformultithreadedapplicationsbyenablingsimultaneousmultithreadingwithineachprocessorcore,uptotwothreadspercore.

    IntelVirtualizationTechnologyintegrateshardware-levelvirtualizationhooksthatallowoperatingsystemvendorstobetterutilizethehardwareforvirtualizationworkloads.

    IntelAdvancedVectorExtensions2.0(AVX2.0)enableaccelerationofenterprise-classworkloadssuchasdatabases,enterpriseresourceplanning,andothers.

    Upto2133MHzmemoryspeedswithtwoDIMMsperchannelrunningat2133MHztohelpmaximize

    systemperformance.

    Upto1.5TBofmemorycapacitywith64GBload-reducedDIMMs,orLRDIMMs(supportfor64GBLRDIMMsisplannedforalaterdate).

    The12GbpsSASinternalstorageconnectivitydoublesthedatatransferratecomparedto6GbSASsolutionstomaximizeperformanceofstorageI/O-intensiveapplications.

    Flexibleandscalableinternalstorageconfigurationsprovideforupto86.4TBofstoragecapacityina2Urackformfactor.

    Theuseofsolid-statedrives(SSDs)insteadoforalongwithtraditionalspinningdrives(HDDs)cansignificantlyimproveI/Operformance.AnSSDcansupportupto100timesmoreI/Ooperationspersecond(IOPS)thanatypicalHDD.

    TheserverhasfourintegratedGigabitEthernetportsandoptional10GbEthernetportswithML2adapters.

    TheserveroffersuptoeightPCIExpress(PCIe)3.0I/OexpansionslotsplusonededicatedPCIe3.0slotforaninternalstoragecontrollerina2Urackformfactor.

    WithIntelIntegratedI/OTechnology,thePCIExpress3.0controllerisintegratedintotheIntelXeonprocessorE5family.ThishelpstodramaticallyreduceI/Olatencyandincreaseoverallsystemperformance.

  • 7/26/2019 Tips 1193

    3/64

    Systemx3650M5 3

    Avai labi l i ty and serviceabi l ity

    Thex3650M5providesmanyfeaturestosimplifyserviceabilityandincreasesystemuptime:

    Tool-lesscoverremovalprovideseasyaccesstoupgradesandserviceableparts,suchasprocessors,memoryDIMMs,andadaptercards.

    Theserveroffershot-swapdrivessupportingRAIDredundancyfordataprotectionandgreatersystemuptime.

    Theserveroffersredundanthot-swappowersuppliesandhot-swapredundantfanstoprovideavailabilityforbusiness-criticalapplications.

    ThenewNextGenlightpathdiagnosticsLCDdisplaypanelsimplifiesservicing,speedsupproblemresolution,andhelpsimprovesystemavailability.

    PredictiveFailureAnalysis(PFA)detectswhensystemcomponents(processors,VRMs,memory,disks,fans,andpowersupplies)operateoutsideofstandardthresholdsandgeneratesproactivealertsinadvanceofpossiblefailure,thereforeincreasinguptime.

    Solid-statedrives(SSDs)offersignificantlybetterreliabilitythantraditionalmechanicalHDDsforgreateruptime.

    Built-inIntegratedManagementModuleII(IMM2.1)continuouslymonitorssystemparameters,triggersalerts,andperformsrecoveryactionsincaseoffailure,tominimizedowntime.

    Built-indiagnosticsusingDynamicSystemsAnalysis(DSA)Prebootspeedsuptroubleshootingtaskstoreduceservicetime.

    Three-yearcustomerreplaceableunitandonsitelimitedwarranty,nextbusinessday9x5.Optionalserviceupgradesareavailable.

    Manage abi l i ty and securi ty

    Powerfulsystemsmanagementfeaturessimplifylocalandremotemanagementofthex3650M5:

    TheserverincludesanIntegratedManagementModuleII(IMM2.1)tomonitorserveravailabilityand

    performremotemanagement.

    Anintegratedindustry-standardUnifiedExtensibleFirmwareInterface(UEFI)enablesimprovedsetup,configuration,andupdates,andsimplifieserrorhandling.

    IBMSystemsDirectorofferscomprehensivesystemsmanagementtoolsthathelptoincreaseuptime,reducecostsandimproveproductivitythroughadvancedservermanagementcapabilities.

    TwointegratedTrustedPlatformModules(TPMs)enableadvancedcryptographicfunctionalitysuchasdigitalsignaturesandremoteattestation.

    SystemxTrustedPlatformAssurance,anexclusivesetofSystemxsecurityfeaturesandpractices,establishesafoolproofsecurityfoundationforworkloadsbydeliveringfirmwarethatissecurelybuilt,tested,digitallysignedandverifiedpriortoexecution.

    Theserveroffersenterprise-classdataprotectionwithoptionalself-encryptingdrivesandsimple,

    centralizedkeymanagementthroughIBMSecurityKeyLifecycleManagement.

    Industry-standardAESNIsupportoffersfaster,strongerencryption.

    IntelExecuteDisableBitfunctionalitycanhelppreventcertainclassesofmaliciousbufferoverflowattackswhencombinedwithasupportingoperatingsystem.

    IntelTrustedExecutionTechnologyprovidesenhancedsecuritythroughhardware-basedresistancetomalicioussoftwareattacks,allowinganapplicationtoruninitsownisolatedspace,protectedfromallothersoftwarerunningonasystem.

  • 7/26/2019 Tips 1193

    4/64

    Systemx3650M5 4

    Energy eff ic iency

    Thex3650M5offersthefollowingenergy-efficiencyfeaturestosaveenergy,reduceoperationalcosts,increaseenergyavailability,andcontributetothegreenenvironment:

    Energy-efficientplanarcomponentshelploweroperationalcosts.

    High-efficiencypowersupplieswith80PLUSPlatinumandTitaniumcertifications.

    IntelIntelligentPowerCapabilitypowersindividualprocessorelementsonandoffasneeded,toreducepowerdraw.

    Low-voltageIntelXeonprocessorsdrawlessenergytosatisfythedemandsofpowerandthermallyconstraineddatacentersandtelecommunicationenvironments.

    Low-voltage1.2VDDR4memoryDIMMsofferenergyefficiencycomparedto1.35VDDR3DIMMs.

    Solid-statedrives(SSDs)consumelesspowerthantraditionalspinningHDDs.

    Theserveruseshexagonalventilationholes,apartofCalibratedVectoredCoolingtechnology.Hexagonalholescanbegroupedmoredenselythanroundholes,providingmoreefficientairflowthroughthesystem.

    IBMSystemsDirectorActiveEnergyManagerprovidesadvanceddatacenterpowernotificationand

    managementtohelpachievelowerheatoutputandreducedcoolingneeds.

    Locat ions of key components and connectors

    Figure2showsthefrontoftheserver.

    Figure2.FrontviewoftheSystemx3650M5

  • 7/26/2019 Tips 1193

    5/64

    Systemx3650M5 5

    Figure3showstherearoftheserver.

    Figure3.RearviewoftheSystemx3650M5

    Figure4showsthelocationsofkeycomponentsinsidetheserver.

    Figure4.InsideviewoftheSystemx3650M5

  • 7/26/2019 Tips 1193

    6/64

    Systemx3650M5 6

    Standard specif ications

    Table1liststhestandardspecifications.

    Table1.Standardspecifications(part1)

    C om ponents S pecific ation

    Machinetype 5462

    Formfactor 2URack.

    Processor UptotwoIntelXeonprocessorE5-2600v3productfamilyCPUswith18or16cores(2.3GHzcorespeeds);or14,12,or10cores(upto2.6GHzcorespeeds);or8cores(upto3.2GHzcorespeeds);or6cores(upto3.4GHzcorespeeds);or4cores(upto3.5GHzcorespeeds).TwoQPIlinksupto9.6GT/seach.Upto2133MHzmemoryspeed.Upto45MBL3cache.

    Chipset IntelC612.

    Memory Upto24DIMMsockets(12DIMMsperprocessor).RDIMMsandLRDIMMsaresupported.Memorytypescannotbeintermixed.Memoryspeedupto2133MHz.

    Memorymaximums

    WithRDIMMs:Upto768GBwith24x32GBRDIMMsandtwoprocessors

    WithLRDIMMs:Upto1.5TBwith24x64GBLRDIMMsandtwoprocessors

    Memoryprotection

    ECC,andChipkill.

    Diskdrivebays Upto26x2.5"hot-swapSAS/SATAdrivebays,orupto14x3.5"+2x2.5"hot-swapSAS/SATAdrivebays,orupto16x2.5"SimpleSwapSATAbays,orupto8x3.5"SimpleSwapSATAbays.Upto4x2.5"NVMePCIeSSDbays.

    Maximuminternalstorage

    Upto46.8TBwith1.8TB2.5"SASHDDs,orupto26TBwith1TB2.5"NLSAS/SATAHDDs,orupto99.8TBwith3.84TB2.5"SASSSDs,orupto87.6TBwith6TB3.5"NLSAS/SATAHDDsand1.8TB2.5"SASHDDs.Upto8TBwith2TBNVMePCIeSSDs.IntermixofSAS/SATA/PCIedrivesissupported.

    Storage

    controller

    Onboard6GbSATA:noRAIDsupport

    12GbSAS/SATARAID:RAID0,1,10withM1215orM5210.OptionalupgradetoRAID5,50isavailableforM1215.OptionalupgradetoRAID5,50isavailableforM5210(zero-cache;1GBnon-backedcache;1GB,2GBor4GBflash-backedcache).OptionalupgradetoRAID6,60isavailableforM5210withmemorycacheupgrades.12GbSAS/SATAnon-RAID:N2215HBA

    Opticaldrivebays

    Oneformodelswith8x3.5"orupto16x2.5"drivebays(modelswith24x2.5"or12x3.5"drivebaysdonotsupportaninternalopticaldrive).SupportforDVD-ROMorMultiburner.

    Tapedrivebays None.

    Networkinterfaces

    FourintegratedRJ-45GigabitEthernet1000BASE-Tports(BCM5719);optionalMezzanineLOM(ML2)slotfordual-port10GbEcardswithSFP+orRJ-45connectorsorquad-portGbEcardswithRJ-45connectors.

  • 7/26/2019 Tips 1193

    7/64

    Systemx3650M5 7

    Table1.Standardspecifications(part2)

    C om ponents S pecific ation

    PCIExpansionslots

    Uptonineslots.Slots0,4,and5arethestandardslotsonthesystemplanar,andtheremainingslotsdependontherisercardsinstalled.Theslotsareasfollows:

    Slot0:PCIe3.0x8(dedicatedforaninternalRAIDcontroller)

    Slot1:PCIe3.0x16orPCIe3.0x8;full-height,full-length(PCIex16slotisdouble-wide)Slot2:PCIe3.0x8;full-height,full-length(notpresentiftheslot1isPCIex16)

    Slot3:PCIe3.0x8orML2;full-height,half-length

    Slot4:PCIe3.0x8;lowprofile(verticalslotonsystemplanar)

    Slot5:PCIe3.0x16;lowprofile(verticalslotonsystemplanar)

    Slot6:PCIe3.0x16orPCIe3.0x8;full-height,full-length(PCIex16slotisdouble-wide)

    Slot7:PCIe3.0x8;full-height,full-length(notpresentiftheslot6isPCIex16)

    Slot8:PCIe3.0x8;full-height,half-length

    Slots5,6,7,and8requirethesecondprocessortobeinstalled.

    Ports Front:1xUSB3.0(8x3.5"andupto16x2.5"drivebaymodels),2xUSB2.0,and1xDB-15video.

    Rear:2xUSB3.0,2xUSB2.0,1xDB-15video,1xRJ-45systemsmanagement,4xRJ-45GbEnetworkports.Optional1xDB-9serialport.Internal:1xUSBport(forembeddedhypervisor).

    Internal:1xSDMediaAdapterslot(forembeddedhypervisor).

    Cooling CalibratedVectoredCoolingwithuptosixredundanthot-swapfans(fourstandard,additionaltwofanswiththesecondprocessor);twofanzoneswithN+1fanredundancy;eachfanhastwomotors.

    Powersupply Uptotworedundanthot-swap550W,750W,900W,or1500WHighEfficiencyPlatinumACpowersupplies,or750Wor1300WHighEfficiencyTitaniumACpowersupplies,or900WHighEfficiency-48VDCpowersupplies.

    Video MatroxG200eR2with16MBmemoryintegratedintotheIMM2.1.Maximumresolutionis1600x1200at75Hzwith16Mcolors.

    Hot-swapparts Harddrives,powersupplies,andfans.

    Systems

    management

    UEFI,IntegratedManagementModuleII(IMM2.1)basedonRenesasSH7758,Predictive

    FailureAnalysis,lightpathdiagnostics,AutomaticServerRestart,ToolsCenter,IBMSystemsDirectorandActiveEnergyManager.OptionalIntegratedManagementModuleAdvancedUpgradesoftwarefeatureforremotepresence.

    Securityfeatures

    Power-onpassword,administrator'spassword,twoTrustedPlatformModules(TPMs):ontheIMM2(TPM1.2)andonthehost(TPM1.2/2.0).Optionallockablefrontbezel.

    Operatingsystemssupported

    MicrosoftWindowsServer2012R2,2012and2008R2,RedHatEnterpriseLinux6and7,SUSELinuxEnterpriseServer11,VMwarevSphere(ESXi)5.1and5.5.

    Limitedwarranty

    Three-yearcustomer-replaceableunitandonsitelimitedwarrantywith9x5nextbusinessday(NBD).

    Serviceand

    support

    OptionalserviceupgradesareavailablethroughServicePac:Four-hourortwo-hourresponse

    time,eight-hourfixtime,one-yearortwo-yearwarrantyextension,remotetechnicalsupportforSystemxhardwareandsomeSystemxthird-partyapplications.

    Dimensions Height:86.5mm(3.4in),width:445.6mm(17.5in),depth:800mm(31.5in)

    Weight Minimumconfiguration:19kg(42lb),maximum:34kg(75lb)

  • 7/26/2019 Tips 1193

    8/64

    Systemx3650M5 8

    Thex3650M5serversincludethefollowingitems:

    StatementofLimitedWarrantyImportantNoticesRackInstallationInstructionsDocumentationCDthatcontainstheInstallationandUser'sGuideSystemxEnterpriseSlidesKit2.8mC13-C14powercord(oneformodelswithonepowersupplyandtwoformodelswithtwopowersupplies)

    Note:CableManagementArm(CMA)isnotincluded.Seethe"Rackoptions"sectionfororderinginformation.

    Standard models

    Table2liststhestandardmodelsofthex3650M5.

    Table2.Standardmodels(Part1)

    MTM Inte l Xeon processor

    (2 maximum)

    Memory

    (RDIMMs)

    R AID D rive

    bays

    (std /

    max)

    D riv es O nbo ar d

    N IC

    I/O

    slots

    (std /

    max)*

    Optical

    drive

    Power

    supply

    (std /

    max)

    ModelsannouncedMay2015

    5462-N2x 1xE5-2660v310C2.6GHz25MB2133MHz105W

    1x16GB2133MHz

    M52102GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x750WHS/2

    5462-P2x 1xE5-2667v38C3.2GHz20MB2133MHz135W

    1x16GB2133MHz

    M52102GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x900WHS/2

    5462-Q2x 1xE5-2697v314C2.6GHz35MB2133MHz145W

    1x16GB2133MHz

    M52102GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x900WHS/2

    #Theletter"x"intheMachineTypeModel(MTM)representsacountry-specificletter(forexample,theEMEAMTM

    is5462-A2G,andtheUSMTMis5462-A2U).AskaLenovorepresentativeforspecifics.Processordetail:Processorquantityandmodel,cores,corespeed,L3cache,memoryspeed,TDP.*Withoneprocessor,onlytwostandardPCIeslots(Slots0and4)canbeused(Slot5requiresthesecondprocessor).IfaRAIDcontrollerispresent,itoccupiesoneofthestandardPCIeslots(Slot0).

  • 7/26/2019 Tips 1193

    9/64

    Systemx3650M5 9

    Table2.Standardmodels(Part2)

    MTM Inte l Xeon processor

    (2 maximum)

    Memory

    (RDIMMs)

    R AID D rive

    bays

    (std /

    max)

    D riv es O nbo ar d

    N IC

    I/O

    slots

    (std /

    max)*

    Optical

    drive

    Power

    supply

    (std /

    max)

    ModelsannouncedSeptember2014

    5462-A2x 1xE5-2603v36C1.6GHz15MB1600MHz85W

    1x8GB2133MHz

    Onboard6GbSATA(noRAID)

    8x2.5"SS/16

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    5462-B2x 1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB2133MHz

    Onboard6GbSATA(noRAID)

    8x3.5"SS/8

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    5462-C2x 1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x16GB2133MHz

    M1215 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    5462-C4x 1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x16GB2133MHz

    M1215 8x3.5"HS/10

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    5462-D2x 1xE5-2630v38C2.4GHz20MB1866MHz85W

    1x16GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    5462-D4x 1xE5-2630v38C2.4GHz20MB1866MHz85W

    1x16GB2133MHz

    M52101GBFlash

    12x3.5"HS/16

    Openbay

    4xGbE 3/9 None 1x750WHS/2

    5462-52x 1xE5-2630Lv38C1.8GHz20MB1866MHz55W

    1x16GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    5462-F2x 1xE5-2640v38C2.6GHz20MB1866MHz90W

    1x16GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    5462-F4x 1xE5-2640v38C2.6GHz20MB1866MHz90W

    1x16GB2133MHz

    M52101GBFlash

    8x2.5"HS/26

    Openbay

    4xGbE 3/9 None 1x750WHS/2

    5462-G2x 1xE5-2650v310C2.3GHz25MB2133MHz105W

    1x16GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x750WHS/2

    5462-62x 1xE5-2670v312C2.3GHz30MB2133MHz120W

    1x16GB2133MHz

    M52102GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x750WHS/2

    5462-J2x 1xE5-2680v312C2.5GHz30MB2133MHz120W

    1x16GB2133MHz

    M52102GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x900WHS/2

    5462-L2x 1xE5-2690v312C2.6GHz30MB2133MHz135W

    1x16GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x900WHS/2

    5462-M2x 1xE5-2699v318C2.3GHz45MB2133MHz145W

    1x16GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x750WHS/2

    #Theletter"x"intheMachineTypeModel(MTM)representsacountry-specificletter(forexample,theEMEAMTMis5462-A2G,andtheUSMTMis5462-A2U).AskaLenovorepresentativeforspecifics.

    Processordetail:Processorquantityandmodel,cores,corespeed,L3cache,memoryspeed,TDP.*Withoneprocessor,onlytwostandardPCIeslots(Slots0and4)canbeused(Slot5requiresthesecondprocessor).IfaRAIDcontrollerispresent,itoccupiesoneofthestandardPCIeslots(Slot0).

    Forthesemodels,thestandardDIMMisratedat2133MHz,butoperatesatalowerspeedtomatchtheprocessor

    memoryspeed.Actualmemoryspeedmaximumsdependonseveralfactors,describedinthe"Memoryoptions"section.Themaximumnumberofthedrivebays(16)include14x3.5"HSbaysand2x2.5"HSbays.

    SeetheSpecificationssectionforinformationaboutstandardfeaturesoftheserver.

  • 7/26/2019 Tips 1193

    10/64

    Systemx3650M5 10

    Express and TopSel ler models

    Table3liststheExpressandTopSellermodelsofthex3650M5.

    Table3.ExpressandTopSellermodels(Part1)

    M TM Inte l Xeon processor

    (2 maximum)

    Memory

    (RDIMMs)

    R AID D rive

    bays

    (std /

    max)

    D riv es O nbo ar d

    N IC

    I/O

    slots

    (std /

    max)*

    Optical

    drive

    Power

    supply

    (std /

    max)

    TopSeller-UnitedStates,Canada

    5462-NAU 1xE5-2603v36C1.6GHz15MB1600MHz85W

    1x8GB2133MHz

    M1215 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    5462-NBU 1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB2133MHz

    M1215 8x3.5"HS/10

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    5462-NCU 1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x16GB2133MHz

    M1215 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    5462-NDU 1xE5-2620v36C2.4GHz

    15MB1866MHz85W

    1x16GB

    2133MHz

    M1215 8x3.5"

    HS/10

    Open

    bay

    4xGbE 3/9 Optional 1x550W

    HS/2

    5462-NEU 1xE5-2630v38C2.4GHz20MB1866MHz85W

    1x16GB2133MHz

    M5210 8x3.5"HS/10

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    5462-NFU 2xE5-2640v38C2.6GHz20MB1866MHz90W

    2x16GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x750WHS/2

    5462-NHU 2xE5-2670v312C2.3GHz30MB2133MHz120W

    4x16GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x900WHS/2

    5462-NJU 1xE5-2680v312C2.5GHz30MB2133MHz120W

    1x16GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x900WHS/2

    5462-NKU 1xE5-2690v312C2.6GHz30MB2133MHz135W

    1x16GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x900WHS/2

    5462-NMU 2xE5-2690v312C2.6GHz30MB2133MHz135W 4x16GB2133MHz M5210 8x2.5"HS/18 Openbay 4xGbE 3/9 Optional 1x900WHS/2

    5462-NNU 1xE5-2643v36C3.4GHz20MB2133MHz135W

    1x16GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x900WHS/2

    5462-NPU 1xE5-2697v314C2.6GHz35MB2133MHz145W

    1x16GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x900WHS/2

    5462-NQU 1xE5-2680v312C2.5GHz30MB2133MHz120W

    1x16GB2133MHz

    N2215 12x3.5"HS/16

    Openbay

    4xGbE 3/9 None 1x900WHS/2

    TopSeller-Europe,MiddleEastandAfrica

    5462-NJG 1xE5-2680v312C2.5GHz30MB2133MHz120W

    1x16GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x900WHS/2

    5462-NPG 1xE5-2697v314C2.6GHz

    35MB2133MHz145W

    1x16GB

    2133MHz

    M5210 8x2.5"

    HS/18

    Open

    bay

    4xGbE 3/9 Optional 1x900W

    HS/2

    Processordetail:Processorquantityandmodel,cores,corespeed,L3cache,memoryspeed,TDP.Forthesemodels,thestandardDIMMisratedat2133MHz,butoperatesatalowerspeedtomatchtheprocessormemoryspeed.Actualmemoryspeedmaximumsdependonseveralfactors,describedinthe"Memoryoptions"section.

    *Withoneprocessor,onlytwostandardPCIeslots(Slots0and4)canbeused(Slot5requiresthesecondprocessor).IfaRAIDcontrollerispresent,itoccupiesoneofthestandardPCIeslots(Slot0).

  • 7/26/2019 Tips 1193

    11/64

    Systemx3650M5 11

    Table3.ExpressandTopSellermodels(Part2)

    M TM Inte l Xeon processor

    (2 maximum)

    Memory

    (RDIMMs)

    R AID D rive

    bays

    (std /

    max)

    D riv es O nbo ar d

    N IC

    I/O

    slots

    (std /

    max)*

    Optical

    drive

    Power

    supply

    (std /

    max)

    TopSeller-LatinAmerica(Brazilonly)

    5462-EVU 1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x16GB2133MHz

    M1215 8x2.5"HS/18

    2x300GB10K

    4xGbE 3/9 Optional 2x550WHS/2

    5462-ETU 1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x16GB2133MHz

    M1215 8x2.5"HS/18

    2x300GB10K

    4xGbE 3/9 Optional 2x750WHS/2

    5462-EUU 1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x16GB2133MHz

    M1215 8x3.5"HS/10

    2x2TB7.2K

    4xGbE 3/9 Optional 2x550WHS/2

    5462-EZU 1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x16GB2133MHz

    2xM1215 8x3.5"HS+2x2.5"HS/10

    2x300GB10K

    4xGbE 4/7 Optional 2x750WHS/2

    5462-EWU

    1xE5-2640v38C2.6GHz20MB1866MHz90W

    1x16GB2133MHz

    M1215 8x2.5"HS/18

    2x300GB10K

    4xGbE 3/9 Optional 2x550WHS/2

    5462-EYU 1xE5-2640v38C2.6GHz20MB1866MHz90W

    1x16GB2133MHz

    M1215 8x3.5"HS/10

    2x2TB7.2K

    4xGbE 3/9 Optional 2x550WHS/2

    5462-E0U 1xE5-2640v38C2.6GHz20MB1866MHz90W

    1x16GB2133MHz

    2xM1215 8x3.5"HS+2x2.5"HS/10

    2x300GB10K

    4xGbE 4/7 Optional 2x750WHS/2

    5462-EUU 1xE5-2640v38C2.6GHz20MB1866MHz90W

    1x16GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    2x300GB10K

    4xGbE 3/9 Optional 2x750WHS/2

    Processordetail:Processorquantityandmodel,cores,corespeed,L3cache,memoryspeed,TDP.Forthesemodels,thestandardDIMMisratedat2133MHz,butoperatesatalowerspeedtomatchtheprocessormemoryspeed.Actualmemoryspeedmaximumsdependonseveralfactors,describedinthe"Memoryoptions"section.*Withoneprocessor,onlytwostandardPCIeslots(Slots0and4)canbeused(Slot5requiresthesecondprocessor).IfaRAIDcontrollerispresent,itoccupiesoneofthestandardPCIeslots(Slot0).

  • 7/26/2019 Tips 1193

    12/64

    Systemx3650M5 12

    Table3.ExpressandTopSellermodels(Part3)

    M TM Inte l Xeon processor

    (2 maximum)

    Memory

    (RDIMMs)

    R AID D rive

    bays

    (std /

    max)

    D riv es O nbo ar d

    N IC

    I/O

    slots

    (std /

    max)*

    Optical

    drive

    Power

    supply

    (std /

    max)

    Express-UnitedStates,Canada

    5462-EAU 1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    1x550WHS/2

    5462-EFU 2xE5-2620v36C2.4GHz15MB1866MHz85W

    2x16GB2133MHz

    M52102GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    2x550WHS/2

    5462-EBU 1xE5-2630v38C2.4GHz20MB1866MHz85W

    1x16GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    1x550WHS/2

    5462-ECU 1xE5-2640v38C2.6GHz20MB1866MHz90W

    1x16GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    1x550WHS/2

    5462-EDU 1xE5-2650v310C2.3GHz25MB2133MHz105W

    1x16GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    1x750WHS/2

    5462-EGU 2xE5-2650v310C2.3GHz25MB2133MHz105W

    4x16GB2133MHz

    M52104GBFlash

    16x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    2x750WHS/2

    5462-EEU 1xE5-2670v312C2.3GHz30MB2133MHz120W

    1x16GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    1x750WHS/2

    Express-LatinAmerica

    5462-ENU 1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    1x550WHS/2

    5462-EOU 1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x8GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    1x550WHS/2

    5462-EPU 1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x8GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    2x300GB10K

    4xGbE 3/9 Multiburner

    2x550WHS/2

    5462-EQU 1xE5-2630v38C2.4GHz

    20MB1866MHz85W

    1x16GB

    2133MHz

    M5210

    1GBFlash

    8x2.5"

    HS/18

    Open

    bay

    4xGbE 3/9 Multi

    burner

    1x550W

    HS/2

    5462-ERU 2xE5-2650v310C2.3GHz25MB2133MHz105W

    2x16GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    2x750WHS/2

    5462-ESU 1xE5-2670v312C2.3GHz30MB2133MHz120W

    1x16GB2133MHz

    M52102GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    1x750WHS/2

    Processordetail:Processorquantityandmodel,cores,corespeed,L3cache,memoryspeed,TDP.Forthesemodels,thestandardDIMMisratedat2133MHz,butoperatesatalowerspeedtomatchtheprocessormemoryspeed.Actualmemoryspeedmaximumsdependonseveralfactors,describedinthe"Memoryoptions"section.

    *Withoneprocessor,onlytwostandardPCIeslots(Slots0and4)canbeused(Slot5requiresthesecondprocessor).IfaRAIDcontrollerispresent,itoccupiesoneofthestandardPCIeslots(Slot0).

  • 7/26/2019 Tips 1193

    13/64

    Systemx3650M5 13

    Table3.ExpressandTopSellermodels(Part4)

    M TM Inte l Xeon processor

    (2 maximum)

    Memory

    (RDIMMs)

    R AID D rive

    bays

    (std /

    max)

    D riv es O nbo ar d

    N IC

    I/O

    slots

    (std /

    max)*

    Optical

    drive

    Power

    supply

    (std /

    max)

    Express-AsiaPacific(AustraliaandNewZealandonly)

    5462-EHM 1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB2133MHz

    M1215 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    1x550WHS/2

    5462-EIM 1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    2x300GB10K

    4xGbE 3/9 Multiburner

    1x550WHS/2

    5462-EJM 1xE5-2620v36C2.4GHz15MB1866MHz85W

    2x8GB2133MHz

    M1215 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    1x550WHS/2

    5462-EKM 1xE5-2620v36C2.4GHz15MB1866MHz85W

    2x8GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    2x300GB10K

    4xGbE 3/9 Multiburner

    1x750WHS/2

    5462-ELM 1xE5-2630v38C2.4GHz20MB1866MHz85W

    2x8GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    1x750WHS/2

    5462-EMM

    2xE5-2650v310C2.3GHz25MB2133MHz105W

    2x16GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    2x750WHS/2

    Express-Japan

    5462-E7J 1xE5-2603v36C1.6GHz15MB1600MHz85W

    1x8GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    5462-E8J 1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    5462-E9J 1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x8GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    Express-Europe,MiddleEastandAfrica

    5462-E1G 1xE5-2603v36C1.6GHz

    15MB1600MHz85W

    1x8GB

    2133MHz

    M5210 8x2.5"

    HS/18

    Open

    bay

    4xGbE 3/9 Multi

    burner

    1x550W

    HS/2

    5462-E2G 1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Optional 1x550WHS/2

    5462-E3G 1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x8GB2133MHz

    M5210 8x2.5"HS/18

    2x300GB10K

    4xGbE 3/9 Multiburner

    2x550WHS/2

    5462-E4G 1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x8GB2133MHz

    M5210 8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    1x550WHS/2

    5462-E5G 1xE5-2630v38C2.4GHz20MB1866MHz85W

    1x8GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    1x550WHS/2

    5462-E6G 1xE5-2640v38C2.6GHz20MB1866MHz90W

    1x16GB2133MHz

    M52101GBFlash

    8x2.5"HS/18

    Openbay

    4xGbE 3/9 Multiburner

    1x750WHS/2

    Processordetail:Processorquantityandmodel,cores,corespeed,L3cache,memoryspeed,TDP.Forthesemodels,thestandardDIMMisratedat2133MHz,butoperatesatalowerspeedtomatchtheprocessormemoryspeed.Actualmemoryspeedmaximumsdependonseveralfactors,describedinthe"Memoryoptions"section.

    *Withoneprocessor,onlytwostandardPCIeslots(Slots0and4)canbeused(Slot5requiresthesecondprocessor).IfaRAIDcontrollerispresent,itoccupiesoneofthestandardPCIeslots(Slot0).

    SeetheSpecificationssectionforinformationaboutstandardfeaturesoftheserver.

  • 7/26/2019 Tips 1193

    14/64

    Systemx3650M5 14

    Processor options

    Thex3650M5supportsprocessoroptionslistedinTable4.Theserversupportsuptotwoprocessors.Thistableshowswhichservermodelshaveeachprocessorasstandard.Ifnocorresponding"whereused"modelexistsforaparticularprocessor,thisprocessorisavailableonlythroughCTO.Secondprocessoroptionsincludetwoextracoolingfans.

    Table4.Processoroptions

    Partnumber

    Feature

    codes*

    Descr ipt ion

    Standard

    mode ls

    where

    used

    00FK640 A5EB/A5EG IntelXeonProcessorE5-2603v36C1.6GHz15MBCache1600MHz85W A2x

    00MU296 ASKU/ASL0 IntelXeonProcessorE5-2608Lv36C2.0GHz15MBCache1866MHz52W -

    00FK641 A5EC/A5EH IntelXeonProcessorE5-2609v36C1.9GHz15MBCache1600MHz85W B2x

    00MU297 ASKV/ASL1 IntelXeonProcessorE5-2618Lv38C2.3GHz20MBCache1866MHz75W -

    00FK642 A5ED/A5EJ IntelXeonProcessorE5-2620v36C2.4GHz15MBCache1866MHz85W C2x,C4x

    00KG846 ASDH/ASDU IntelXeonProcessorE5-2623v34C3.0GHz10MBCache1866MHz105W -

    00MU298 ASKW/ASL2 IntelXeonProcessorE5-2628Lv310C2.0GHz25MBCache1866MHz75W -

    00FK643 A5EE/A5EK IntelXeonProcessorE5-2630v38C2.4GHz20MBCache1866MHz85W D2x,D4x

    00FK655 A5EF/A5ES IntelXeonProcessorE5-2630Lv38C1.8GHz20MBCache1866MHz55W 52x

    00KG847 ASDJ/ASDV IntelXeonProcessorE5-2637v34C3.5GHz15MBCache2133MHz135W -

    00FK644 A5GT/A5EL IntelXeonProcessorE5-2640v38C2.6GHz20MBCache1866MHz90W F2x,F4x

    00KG848 ASDK/ASDW IntelXeonProcessorE5-2643v36C3.4GHz20MBCache2133MHz135W -

    00MU299 ASKX/ASL3 IntelXeonProcessorE5-2648Lv312C1.8GHz30MBCache2133MHz75W -

    00FK645 A5GU/A5EM IntelXeonProcessorE5-2650v310C2.3GHz25MBCache2133MHz105W G2x

    00KG845 ASDG/ASDT IntelXeonProcessorE5-2650Lv312C1.8GHz30MBCache2133MHz65W -

    00MU300 ASKY/ASL4 IntelXeonProcessorE5-2658v312C2.2GHz30MBCache2133MHz105W -

    00KG839 ASDA/ASDM IntelXeonProcessorE5-2660v310C2.6GHz25MBCache2133MHz105W N2x

    00KG849 ASDL/ASDX IntelXeonProcessorE5-2667v38C3.2GHz20MBCache2133MHz135W P2x

    00FK647 A5GV/A5EN IntelXeonProcessorE5-2670v312C2.3GHz30MBCache2133MHz120W 62x

    00FK648 A5GW/A5EP IntelXeonProcessorE5-2680v312C2.5GHz30MBCache2133MHz120W J2x

    00KG840 ASDB/ASDN IntelXeonProcessorE5-2683v314C2.0GHz35MBCache2133MHz120W -

    00KG841 ASDC/ASDP IntelXeonProcessorE5-2685v312C2.6GHz30MBCache2133MHz120W -

    00FK649 A5GX/A5EQ IntelXeonProcessorE5-2690v312C2.6GHz30MBCache2133MHz135W L2x

    00KG842 ASDD/ASDQ IntelXeonProcessorE5-2695v314C2.3GHz35MBCache2133MHz120W -

    00KG843 ASDE/ASDR IntelXeonProcessorE5-2697v314C2.6GHz35MBCache2133MHz145W Q2x

    00KG844 ASDF/ASDS IntelXeonProcessorE5-2698v316C2.3GHz40MBCache2133MHz135W -

    00KF372 ARYJ/ARYT IntelXeonProcessorE5-2699v318C2.3GHz45MBCache2133MHz145W M2x

    *Thefirstfeaturecodeisforthefirstprocessor;thesecondfeaturecodeisforthesecondprocessor.

  • 7/26/2019 Tips 1193

    15/64

    Systemx3650M5 15

    Mem ory opt ions

    TheSystemx3650M5supportsTruDDR4memory.TruDDRMemoryusesthehighestqualitycomponentssourcedfromTier1DRAMsuppliersandonlymemorythatmeetsourstrictrequirementsisselected.ItiscompatibilitytestedandtunedoneverySystemxservertomaximizeperformanceandreliability.TruDDR4MemoryhasauniquesignatureprogrammedintotheDIMMthatenablesSystemx

    serverstoverifywhetherthememoryinstalledisqualifiedorsupported.BecauseTruDDR4Memoryisauthenticated,certainextendedmemoryperformancefeaturescanbeenabledtoextendperformanceoverindustrystandards.Fromaserviceandsupportstandpoint,Systemxmemoryautomaticallyassumesthesystem'swarranty,andserviceandsupportprovidedworldwide.

    Theserversupportsupto12DIMMswhenoneprocessorisinstalledandupto24DIMMswhentwoprocessorsareinstalled.Eachprocessorhasfourmemorychannels;therearethreeDIMMsperchannel.

    Thefollowingrulesapplywhenselectingthememoryconfiguration:

    TheserversupportsRDIMMsandLRDIMMs.

    Mixingtypesofmemory(RDIMMsandLRDIMMs)isnotsupported.

    ThemaximumquantityofDIMMsthatcanbeinstalledintheserverdependsonthenumberofprocessors.

    AllDIMMsintheserveroperateatthesamespeed,whichisdeterminedasthelowestvalueofthese:

    Memoryspeedthatissupportedbythespecificprocessor.

    LowestofmaximumoperatingspeedsforselectedmemoryconfigurationthatdependsonquantityofDIMMsperchannel,asshownunder"Maximumoperatingspeed"sectioninTable5.

    Thefollowingmemoryprotectiontechnologiesaresupported:

    ECCChipkill(forx4-basedmemoryDIMMs)

    Chipkillworksonlyinindependentchannelmode(thedefaultisoperationalmode)andsupportsonlyx4-basedmemoryDIMMs.

  • 7/26/2019 Tips 1193

    16/64

    Systemx3650M5 16

    Table5showsthecharacteristicsofthesupportedDIMMs.TablescellshighlightedwithagraybackgroundindicatewhenthenumberofDIMMsperchannelstillallowstheDIMMstooperateataratedspeed.

    Table5.Maximummemoryspeeds

    DIM M specification RDIM M LRDIM M

    Rank Singlerank Dualrank Quadrank

    Partnumbers 46W0784(4GB)46W0788(8GB)

    46W0792(8GB) 46W0796(16GB)95Y4808(32GB)

    46W0800(32GB)95Y4812(64GB)

    Ratedspeed 2133MHz 2133MHz 2133MHz 2133MHz

    Ratedvoltage 1.2V 1.2V 1.2V 1.2V

    Maximumquantitysupported** 24 24 24 24

    MaximumDIMMcapacity 8GB 8GB 32GB 64GB

    Maximummemorycapacity 192GB 192GB 768GB 1.5TB

    Maximummemoryatratedspeed 64GB 64GB 512GB 512GB

    Maximum operat ing speed

    1DIMMperchannel 2133MHz 2133MHz 2133MHz 2133MHz

    2DIMMsperchannel 2133MHz 2133MHz 2133MHz 2133MHz

    3DIMMsperchannel 1600MHz 1600MHz 1866MHz 1866MHz

    **Themaximumquantitythatissupportedisshownfortwoprocessorsinstalled.

  • 7/26/2019 Tips 1193

    17/64

    Systemx3650M5 17

    Table6listsavailablememoryoptionsforthex3650M5server.

    Table6.Memoryoptions

    Partnumber

    Feature

    code

    Description M axim um

    suppor ted

    Standard models

    where used

    RDIMMs-2133MHz

    46W0784 A5B6 4GBTruDDR4Memory(1Rx8,1.2V)PC4-17000CL152133MHzLPRDIMM

    24(12perCPU)

    -

    46W0788 A5B5 8GBTruDDR4Memory(1Rx4,1.2V)PC4-17000CL152133MHzLPRDIMM

    24(12perCPU)

    -

    46W0792 A5B8 8GBTruDDR4Memory(2Rx8,1.2V)PC4-17000CL152133MHzLPRDIMM

    24(12perCPU)

    A2x,B2x

    46W0796 A5B7 16GBTruDDR4Memory(2Rx4,1.2V)PC4-17000CL152133MHzLPRDIMM

    24(12perCPU)

    52x,62x,C2x,C4x,D2x,D4x,F2x,F4x,G2x,J2x,L2x,M2x,N2x,P2x,Q2x

    95Y4808 A5UJ 32GBTruDDR4Memory(2Rx4,1.2V)PC4-17000CL152133MHzLPRDIMM

    24(12perCPU)

    -

    LRDIMMs-2133MHz

    46W0800 A5B9 32GBTruDDR4Memory(4Rx4,1.2V)PC4-17000CL152133MHzLPLRDIMM

    24(12perCPU)

    -

    95Y4812 A5UK 64GBTruDDR4Memory(4Rx4,1.2V)PC4-17000CL152133MHzLPLRDIMM

    24(12perCPU)

    -

    Internal storage

    TheSystemx3650M5serversupportsthefollowingconfigurations:

    8x2.5-inchSAS/SATAhot-swapdrivebaystoragedenseservermodelsthatcanbeupgradedto261.(24onthefront;2ontherear)2.5-inchSAS/SATAhot-swapdrivebays

    8x2.5-inchSAS/SATAhot-swapdrivebayservermodelsthatcanbeupgradedtothefollowingdrive2.bayconfigurations:

    8x2.5-inchSAS/SATAhot-swapdrivebay+4x2.5-inchPCIeSSDhot-swapdrivebaysa.

    16x2.5-inchSAS/SATAhot-swapdrivebay+4x2.5-inchPCIeSSDhot-swapdrivebaysb.

    18x(16onthefront;2ontherear)2.5-inchSAS/SATAhot-swapdrivebaysc.

    8x2.5-inchSATASimpleSwapdrivebayservermodelsthatcanbeupgradedto16x2.5-inchSATA3.SimpleSwapdrivebays

    8x3.5-inchSAS/SATAhot-swapdrivebayservermodelsthatcanbeupgradedto10(8onthefront;24.ontherear)3.5-inchSAS/SATAhot-swapdrivebaysor8x3.5-inchplus2x2.5-inchSAS/SATAhot-swapdrivebays(foratotalof10drivebays)

    8x3.5-inchSATASimpleSwapdrivebayservermodels5.

    12x3.5-inchSAS/SATAhot-swapdrivebayservermodelsthatcanbeupgradedto14(12onthe6.front;2ontherear)3.5-inchSAS/SATAhot-swapdrivebaysplus2x2.5-inchSAS/SATAhot-swapdrivebays(foratotalof16drivebays)

  • 7/26/2019 Tips 1193

    18/64

    Systemx3650M5 18

    Figure5showsthefrontdriveconfigurations.

    Figure5.Internalfrontdriveconfigurations

  • 7/26/2019 Tips 1193

    19/64

    Systemx3650M5 19

    Figure6showstheconfigurationswiththereardrivekitupgrades.

    Figure6.Internalreardriveconfigurations

    Note:TheRear2.5"HDDKitisinstalledinplaceofthePCIeRiserCard1,andPCIeslots1,2and3arenotpresent.ThekitincludesspecialriserthatprovidesPCIe3.0x8slot3fortheM1215RAIDcontrollerthatisdedicatedtorear2.5-inchdrives.TheRear3.5"HDDKitisinstalledinplaceofPCIeRiserCard2;PCIeslots6,7,and8arenotpresent.Seethe"I/Oexpansionoptions"sectionformoreinformation.

  • 7/26/2019 Tips 1193

    20/64

    Systemx3650M5 20

    Table7showstheinternalstorageoptionsavailableforthex3650M5server.

    Table7.Internalstorageoptions

    Partnumber

    Feature

    code

    Description M axim um

    suppor ted

    Standard models

    where used

    Basedrivekits(factoryinstalled)*

    None* A5G6 x3650M58x2.5"HSHDDAssemblyKit(SingleRAID) 1 52x,62x,C2x,D2x,F2x,F4x,G2xJ2x,L2x,N2x,P2x,Q2x

    None* A5GF x3650M516x2.5"HSHDDAssemblyKit(SingleRAID) 1 -

    None* A5GG x3650M516x2.5"HSHDDAssemblyKit(DualRAID) 1 -

    None* A5G7 x3650M524x2.5"HSHDDAssemblyKit(SingleRAID) 1 -

    None* A5TN x3650M524x2.5"HSHDDAssemblyKit(DualRAID) 1 -

    None* A5G8 x3650M524x2.5"HSHDDAssemblyKit(TripleRAID) 1 -

    None* A5G9 x3650M58x2.5"SSHDDAssemblyKit(non-RAID) 1 A2x

    00MU147 A5GB x3650M58x2.5"SSHDDServeRAIDAssemblyKit 1 -

    None* A5GD x3650M58x3.5"HSHDDAssemblyKit 1 C4x

    None* A5GE x3650M512x3.5"HSHDDAssemblyKit 1 D4x

    None* A5GA x3650M58x3.5"SSHDDAssemblyKit(non-RAID) 1 B2x

    00MU148 A5GC x3650M58x3.5"SSHDDServeRAIDAssemblyKit 1 -

    None* A5GH Systemx3650M5Rear2x2.5"HDDKit(IndependentRAID)

    1 -

    None* A5GL Systemx3650M5Rear2x3.5"HDDKit(Cascaded) 1 -

    None* A5GK Systemx3650M5Rear2x3.5"HDDKit(IndependentRAID) 1 -

    None* ASRL Systemx3650M5Plus4x2.5"NVMePCIeSSDUpgradeKit

    1 -

    Upgradedrivekits(requirethebasedrivekit)**

    00FK661 AS44 Systemx3650M5Plus8x2.5"HSHDDAssemblyKitwithExpander

    2 -

    00FK676 AS45 Systemx3650M5Plus8x2.5"HSHDDAssemblyKit 2 -

    00MU147 A5GB x3650M58x2.5"SSHDDServeRAIDAssemblyKit 1 -

    00MU148 A5GC x3650M58x3.5"SSHDDServeRAIDAssemblyKit 1 -

    00FK658 AS42 Systemx3650M5Rear2x2.5"HDDKit 1 -

    00FK659 AS43 Systemx3650M5Rear2x3.5"HDDKit 1 -

    00FK677 None** Systemx3650M5Plus4x2.5"NVMePCIeSSDUpgradeKit

    1 -

    *Basedrivekitsarealwaysfactory-installedineitherstandardorcustom(CTOorSpecialBid)models,andtheymightnothaveanoptionpartnumberassigned.

    **Upgradedrivekitscanbeinstalledasafieldupgradeforsupportedstandardorcustommodels,andtheymightnothaveafeaturecodeassigned.

  • 7/26/2019 Tips 1193

    21/64

    Systemx3650M5 21

    Table8listspossiblefactory-installedinternalstorageconfigurationsandfieldupgrades.

    Table8.Internalstorageconfigurations(FC=FeatureCode,PN=PartNumber,qty=quantity)(Part1)

    Drive bay type Drive

    bay qty

    S to ra ge co ntro lle r* D riv e k it s re qu ire d

    Frontdrivebays

    8 1xRAIDorHBA(8drives)

    Factoryinstalled1xx3650M58x2.5"HSHDDAssemblyKit(SingleRAID)(FCA5G6)

    1xRAIDorHBA(16drives)

    Factoryinstalled1xx3650M516x2.5"HSHDDAssemblyKit(SingleRAID)(FCA5GF)

    Fieldupgradefor8x2.5-inchHSdrivebaymodels:1xSystemx3650M5Plus8x2.5"HSHDDAssemblyKitwithExpander(PN00FK661)

    16

    2xRAIDorHBA(8+8drives)

    Factoryinstalled1xx3650M516x2.5"HSHDDAssemblyKit(DualRAID)(FCA5GG)

    Fieldupgradefor8x2.5-inchHSdrivebaymodels:1xSystemx3650M5Plus8x2.5"HSHDDAssemblyKit(PN00FK676)

    1xRAIDorHBA(24drives)

    Factoryinstalled1xx3650M524x2.5"HSHDDAssemblyKit(SingleRAID)(FCA5G7)

    Fieldupgradefor16(8+8)x2.5-inchHSdrivebaymodels:

    1xSystemx3650M5Plus8x2.5"HSHDDAssemblyKitwithExpander(PN00FK661)

    2xRAIDorHBA(16+8drives)

    Factoryinstalled1xx3650M524x2.5"HSHDDAssemblyKit(DualRAID)(FCA5TN)

    Fieldupgradefor16(8+8)x2.5-inchHSdrivebaymodels:

    1xSystemx3650M5Plus8x2.5"HSHDDAssemblyKitwithExpander(PN00FK661)

    Fieldupgradefor16(16)x2.5-inchHSdrivebaymodels:

    1xSystemx3650M5Plus8x2.5"HSHDDAssemblyKit(PN00FK676)

    2.5-inchSAS/SATAhot-swap(front)

    24

    3xRAIDorHBA(8+8+8drives)

    Factoryinstalled1xx3650M524x2.5"HSHDDAssemblyKit(TripleRAID)(FCA5G8)

    Fieldupgradefor16(8+8)x2.5-inchHSdrivebaymodels:

    1xSystemx3650M5Plus8x2.5"HSHDDAssemblyKit(PN00FK676)

  • 7/26/2019 Tips 1193

    22/64

    Systemx3650M5 22

    Table8.Internalstorageconfigurations(FC=FeatureCode,PN=PartNumber,qty=quantity)(Part2)

    Drive bay type Drive

    bay

    qty

    S tora ge c on trolle r* D riv e k its re qu ire d

    2.5-inchPCIeSSDhot-swap(front)

    4 2xPCIeExtenders#(2+2)

    Factoryinstalled1xSystemx3650M5Plus4x2.5"NVMePCIeSSDUpgradeKit(FCASRL)Requiresastorageconfigurationwith8xor16x2.5-inchSAS/SATAhot-swapdrivebays**

    Fieldupgradefor8xor16x2.5-inchSAS/SATAHSdrivebaymodels

    1xSystemx3650M5Plus4x2.5"NVMePCIeSSDUpgradeKit(PN00FK677)

    Integrated8-port6GbpsSATA(8drives;noRAIDsupport)

    Factoryinstalled1xx3650M58x2.5"SSHDDAssemblyKit(non-RAID)(FCA5G9)

    8

    1xRAIDorHBA

    (8drives) Factoryinstalled1xx3650M58x2.5"SSHDDServeRAIDAssemblyKit(FCA5GB)

    Fieldupgradefor8x2.5-inchSSdrivebaymodelswithoutRAIDorHBA:

    1xx3650M58x2.5"SSHDDServeRAIDAssemblyKit(PN00MU147)

    2.5-inchSATASimpleSwap(front)

    16 2xRAIDorHBA(8+8drives)

    Factoryinstalled2xx3650M58x2.5"SSHDDServeRAIDAssemblyKit(FCA5GB)

    Fieldupgradefor8x2.5-inchSSdrivebaymodelswithRAIDorHBA:

    1xx3650M58x2.5"SSHDDServeRAIDAssemblyKit(PN00MU147)

    8 1xRAIDorHBA(8drives)

    Factoryinstalled1xx3650M58x3.5"HSHDDAssemblyKit(FCA5GD)

    3.5-inchSAS/SATAhot-swap(front)

    12 1xRAIDorHBA(12drives)

    Factoryinstalled1xx3650M512x3.5"HSHDDAssemblyKit(FCA5GE)

    Integrated8-port6GbpsSATA(noRAIDsupport)

    Factoryinstalled1xx3650M58x3.5"SSHDDAssemblyKit(non-RAID)(FCA5GA)

    3.5-inchSATASimpleSwap(front)

    8

    1xRAIDorHBA(8drives)

    Factoryinstalled1xx3650M58x3.5"SSHDDServeRAIDAssemblyKit(FCA5GC)

    Fieldupgradefor8x3.5-inchSSdrivebaymodelswithoutRAIDorHBA:

    1xx3650M58x3.5"SSHDDServeRAIDAssemblyKit(PN00MU148)

  • 7/26/2019 Tips 1193

    23/64

    Systemx3650M5 23

    Table8.Internalstorageconfigurations(FC=FeatureCode,PN=PartNumber,qty=quantity)(Part3)

    Drive bay type Drive

    bay qty

    S to ra ge co ntro lle r* D riv e k it s re qu ire d

    Reardrivebays

    2.5-inchSAS/SATA

    hot-swap(rear)

    2 1xM1215

    (2drives)

    Factoryinstalled

    1xSystemx3650M5Rear2x2.5"HDDKit(IndependentRAID)(FCA5GH)

    Fieldupgradefor2.5-inchand3.5-inchHSdrivebaymodels:

    1xSystemx3650M5Rear2x2.5"HDDKit(PN00FK658)

    1xRAIDorHBA(12+2drives)***

    Factoryinstalled1xSystemx3650M5Rear2x3.5"HDDKit(Cascaded)(FCA5GL)

    Fieldupgradefor3.5-inchHSdrivebaymodels:1xSystemx3650M5Rear2x3.5"HDDKit(PN00FK659)

    3.5-inchSAS/SATAhot-swap(rear)

    2

    1xM1215(2drives)

    Factoryinstalled1xSystemx3650M5Rear2x3.5"HDDKit(IndependentRAID)(FCA5GK)

    Fieldupgradefor3.5-inchHSdrivebaymodels:1xSystemx3650M5Rear2x3.5"HDDKit(PN00FK659)

    *IntheStoragecontrollercolumn,RAIDorHBAmeansthatanycombinationoftheM1215,M5210,andN2215storagecontrollersissupporteduptoamaximumquantitylisted;thenumbersinbrackets(x+y+z)specifythenumberofdrivesconnectedtoeachofthestoragecontrollers.#EachPCIeSSDExtenderAdapter(PN00ML997)providesconnectivityforuptotwoPCIeSSDs,andeachadapteroccupiesaPCIeslot.Forfactoryconfiguredmodels,twoPCIeSSDExtenderAdapters(FCAS95)mustbeincluded

    intheconfiguration.Forfieldupgrades,thePCIeSSDUpgradeKit(PN00FK677)includestwoPCIeSSDExtenders.**OneofthefirstthreestorageconfigurationslistedinTable8.For16x2.5-inchSAS/SATAhot-swapdrivebayconfigurations,theinternalopticaldriveisnotsupported.***Twodrivesinthe2x3.5-inchRearHDDKitareconnectedtotheSASexpanderonthe12-drivebackplane,thatis,tothesamestoragecontrolleras12drivesonthefront.

  • 7/26/2019 Tips 1193

    24/64

    Systemx3650M5 24

    Thefollowingadditionalrulesapplytothestorageconfigurations:

    24x2.5-inchdrivesaresupportedonstoragedensemodelsonly(modelswithouttheSystemx3650M52.5"ODD/LCDLightPathBay,FCA5FY;thefirstconfigurationinFigure5).

    2x2.5-inchreardrivesaresupportedon2.5-inchand3.5-inchhot-swapdrivebaymodels.

    Ifthe2x3.5-inchRearHDDKitisinstalledandconnectedtoadedicatedcontroller,the2x2.5-inchRearHDDKitcannotbeinstalled.

    2x3.5-inchreardrivesaresupportedon3.5-inchhot-swapdrivebaymodelsonly.

    With8x3.5-inchHSdrivebaymodels,the2x3.5-inchRearHDDKitisconnectedtoadedicatedM1215controller,andthe2x2.5-inchRearHDDKitcannotbeinstalled.

    With12x3.5-inchHSdrivebaymodels,the2x3.5-inchRearHDDKitcanbeconnectedtoadedicatedM1215controllerorSASexpanderonthe12-drivebackplane.Ifthe2x3.5-inchRearHDDKitisconnectedtoadedicatedM1215controller,the2x2.5-inchRearHDDKitcannotbeinstalled.Ifthe2x3.5-inchRearHDDKitisconnectedtoaSASexpander,the2x2.5-inchRearHDDKitcanbeinstalled.

    Both2.5-inchand3.5-inchRearHDDKitsarenotsupportedonSimpleSwapmodels.

    NVMePCIeSSDsaresupportedon8xor16x2.5-inchSAS/SATAhot-swapdrivebaymodelsonly.

    For16x2.5-inchSAS/SATAhot-swapdrivebayconfigurations,theinternalopticaldriveisnotsupportedintheconfigurationswithNVMePCIeSSDs.RearHDDkitsarenotsupportedintheconfigurationswithNVMePCIeSSDs.

  • 7/26/2019 Tips 1193

    25/64

    Systemx3650M5 25

    Control lers for internal storage

    Table9liststhestoragecontrollersandadditionaloptionsusedforinternaldiskstorageofx3650M5server.

    Table9.RAIDcontrollersandHBAsforinternalstorage

    Partnumber

    Feature

    code

    Description M axim um

    suppor ted

    Standard models

    where used

    12GbSAS/SATAcontrollers

    46C9110 A3YZ ServeRAIDM5210SAS/SATAController 3 62x,D2x,D4x,F2x,F4x,G2x,J2x,L2x,M2x,N2x,P2x,Q2x

    46C9114 A45W ServeRAIDM1215SAS/SATAController 4 C2x,C4x

    47C8675 A3YY N2215SAS/SATAHBA 3 -

    HardwareupgradesfortheM5210

    47C8656 A3Z0 ServeRAIDM5200Series1GBCache/RAID5Upgrade 3 -

    47C8660 A3Z1 ServeRAIDM5200Series1GBFlash/RAID5Upgrade 3 D2x,D4x,F2x,F4x,G2x

    47C8664 A3Z2 ServeRAIDM5200Series2GBFlash/RAID5Upgrade 3 62x,J2x,N2x,P2x,Q2x

    47C8668 A3Z3 ServeRAIDM5200Series4GBFlash/RAID5Upgrade 3 -

    FeaturesonDemandupgradesfortheM5210*

    47C8708 A3Z6 ServeRAIDM5200SeriesZeroCache/RAID5Upgrade 1 -

    47C8706 A3Z5 ServeRAIDM5200SeriesRAID6Upgrade 1** -

    47C8710 A3Z7 ServeRAIDM5200SeriesPerformanceAccelerator 1** -

    47C8712 A3Z8 ServeRAIDM5200SeriesSSDCachingEnabler 1** -

    FeaturesonDemandupgradesfortheM1215*

    00AE930 A5H5 ServeRAIDM1200ZeroCache/RAID5UpgradeforFOD

    1 -

    PCIeextenders(forNVMePCIeSSDs)

    00ML997 AS95 SystemxNVMePCIeSSDExtenderAdapter 2 -

    *FeaturesonDemand(FoD)upgradesforServeRAIDadaptersareappliedsystem-wide,thatisoneFoDupgradeisrequiredtoactivatethefeatureonallRAIDcontrollersofthesametypeinstalledintheserver.

    **Requirescachememoryupgrade(47C8656,47C8660,47C8664,or47C8668).

  • 7/26/2019 Tips 1193

    26/64

    Systemx3650M5 26

    TheServeRAIDM1215SAS/SATAControllerhasthefollowingspecifications:

    Eightinternal12GbpsSAS/SATAportsUpto12GbpsthroughputperportTwointernalmini-SASHDconnectors(SFF-8643)SupportsconnectionstoSAS/SATAHDDsandSSDsLSISAS300812GbpsRAIDonChip(ROC)controllerSupportforRAIDlevels0,1,and10standard;supportforRAID5,50withoptionalFoDupgradeZeroControllerCache,nobattery/flashbackupOptionalsupportforself-encryptingdrives(SEDs)withMegaRAIDSafeStore(withRAID5upgrade)Fixedstripesizeof64KB

    TheServeRAIDM5210SAS/SATAControllerhasthefollowingspecifications:

    Eightinternal12GbpsSAS/SATAportsUpto12GbpsthroughputperportTwox4HDmini-SASinternalconnectors(SFF-8643)SupportsconnectionstoSAS/SATAHDDsandSSDsandSASExpandersSupportsRAID0,1,and10SupportsRAID5and50withoptionalM5200SeriesRAID5upgrades

    SupportsRAID6and60withtheoptionalM5200SeriesRAID6upgradeOptionalsupportforself-encryptingdrives(SEDs)withMegaRAIDSafeStore(withRAID5upgrade)Supports1GBnon-backedcacheor1GB,2GBor4GBflash-backedcachePCIe3.0x8hostinterfaceBasedontheLSISAS310812GbpsROCcontroller

    TheN2215SAS/SATAHBAhasthefollowingspecifications:

    Eightinternal12GbpsSAS/SATAportsUpto12GbpsthroughputperportTwox4HDmini-SASinternalconnectors(SFF-8643)SupportsconnectionstoSAS/SATAHDDsandSSDsOptimizedforSSDperformance

    NoRAIDsupportPCIe3.0x8hostinterfaceBasedontheLSISAS300812Gbpscontroller

    Formoreinformation,seethelistofProductGuidesintheRAIDadapterscategory:http://lenovopress.com/systemx/raid

    http://lenovopress.com/systemx/raidhttp://lenovopress.com/systemx/raid
  • 7/26/2019 Tips 1193

    27/64

    Systemx3650M5 27

    Internal dr ive options

    Table10listsdriveoptions.

    Table10.Driveoptionsforinternalstorage(Part1)

    Part

    number

    Feature

    code

    Description M axim um

    suppor ted

    2.5-inchhot-swap12GbpsSASHDDs

    00NA221 ASBB 300GB15K12GbpsSAS2.5"G3HS512eHDD 26

    00NA241 ASBF 600GB10K12GbpsSAS2.5"G3HS512eHDD 26

    00NA231 ASBD 600GB15K12GbpsSAS2.5"G3HS512eHDD 26

    00NA251 ASBH 900GB10K12GbpsSAS2.5"G3HS512eHDD 26

    00NA261 ASBK 1.2TB10K12GbpsSAS2.5"G3HS512eHDD 26

    00NA271 ASBM 1.8TB10K12GbpsSAS2.5"G3HS512eHDD 26

    2.5-inchhot-swap12GbpsSASSEDs

    00NA281 ASBP 300GB15K12GbpsSAS2.5"G3HS512eSED 26

    00NA291 ASBR 600GB10K12GbpsSAS2.5"G3HS512eSED 26

    00NA286 ASBQ 600GB15K12GbpsSAS2.5"G3HS512eSED 26

    00NA296 ASBS 900GB10K12GbpsSAS2.5"G3HS512eSED 26

    00NA301 ASBT 1.2TB10K12GbpsSAS2.5"G3HS512eSED 26

    00NA306 ASBU 1.8TB10K12GbpsSAS2.5"G3HS512eSED 26

    2.5-inchhot-swap12GbpsSASHybriddrives

    00NA311 ASBV 300GB15K12GbpsSAS2.5"G3HS512eHybrid 26

    00NA321 ASBX 600GB15K12GbpsSAS2.5"G3HS512eHybrid 26

    2.5-inchhot-swap12GbpsSASEnterpriseSSDs

    00FN379 AS7C 200GB12GSAS2.5"MLCG3HSEnterpriseSSD 26

    00FN389 AS7E 400GB12GSAS2.5"MLCG3HSEnterpriseSSD 26

    00FN399 AS7G 800GB12GSAS2.5"MLCG3HSEnterpriseSSD 26

    00FN409 AS7J 1.6TB12GSAS2.5"MLCG3HSEnterpriseSSD 26

    2.5-inchhot-swap12GbpsSASSEDEnterpriseSSDs

    00FN419 AS7L 400GBSED12GSAS2.5"MLCG3HSEnterpriseSSD 26

    00FN424 AS7M 800GBSED12GSAS2.5"MLCG3HSEnterpriseSSD 26

  • 7/26/2019 Tips 1193

    28/64

    Systemx3650M5 28

    Table10.Driveoptionsforinternalstorage(Part2)

    Partnumber

    Feature

    code

    Description M axim um

    suppor ted

    2.5"simple-swap12GbpsSASEnterpriseSSDs

    00FN384 AS7D 200GB12GSAS2.5"MLCG3SSEnterpriseSSD 16

    00FN394 AS7F 400GB12GSAS2.5"MLCG3SSEnterpriseSSD 16

    00FN404 AS7H 800GB12GSAS2.5"MLCG3SSEnterpriseSSD 16

    00FN414 AS7K 1.6TB12GSAS2.5"MLCG3SSEnterpriseSSD 16

    2.5-inchhot-swap6GbpsSASHDDs

    00AJ096 A4TL 300GB10K6GbpsSAS2.5"G3HSHDD 26

    00AJ081 A4TR 300GB15K6GbpsSAS2.5"G3HSHDD 26

    00AJ091 A4TM 600GB10K6GbpsSAS2.5"G3HSHDD 26

    00AJ126 A4TS 600GB15K6GbpsSAS2.5"G3HSHDD 26

    00AJ071 A4TN 900GB10K6GbpsSAS2.5"G3HSHDD 26

    00AJ146 A4TP 1.2TB10K6GbpsSAS2.5"G3HSHDD 26

    2.5-inchhot-swap6GbpsNLSASHDDs

    00AJ121 A4TT 500GB7.2K6GbpsNLSAS2.5"G3HSHDD 26

    00AJ086 A4TU 1TB7.2K6GbpsNLSAS2.5''G3HSHDD 26

    2.5-inchhot-swap6GbpsNLSATAHDDs

    00AJ136 A4TW 500GB7.2K6GbpsNLSATA2.5"G3HSHDD 26

    00AJ141 A4TX 1TB7.2K6GbpsNLSATA2.5"G3HSHDD 26

    2.5-inchsimple-swap6GbpsNLSATAHDDs

    00NA597 ASLC 500GB7.2K6GbpsNLSATA2.5"G3SSHDD 16

    00NA622 ASLD 1TB7.2K6GbpsNLSATA2.5"G3SSHDD 16

  • 7/26/2019 Tips 1193

    29/64

    Systemx3650M5 29

    Table10.Driveoptionsforinternaldiskstorage(Part3)

    Partnumber

    Feature

    code

    Description M axim um

    suppor ted

    2.5-inchhot-swap6GbpsSASEnterpriseSSDs

    00AJ207 A4UA 200GBSAS2.5"MLCG3HSEnterpriseSSD 26

    00AJ212 A4UB 400GBSAS2.5"MLCG3HSEnterpriseSSD 26

    00AJ217 A4UC 800GBSAS2.5"MLCG3HSEnterpriseSSD 26

    00AJ222 A4UD 1.6TBSAS2.5"MLCG3HSEnterpriseSSD 26

    2.5-inchhot-swap6GbpsSASEnterpriseCapacitySSDs

    00NA671 ASW6 3.84TB6GbSASEnterpriseCapacityG3HSMLCSSD 26

    2.5-inchhot-swap6GbpsSATAEnterpriseSSDs

    00AJ156 A4U3 S3700200GBSATA2.5"MLCG3HSEnterpriseSSD 26

    00AJ161 A4U4 S3700400GBSATA2.5"MLCG3HSEnterpriseSSD 26

    00AJ166 A4U5 S3700800GBSATA2.5"MLCG3HSEnterpriseSSD 26

    2.5-inchhot-swap6GbpsSATAEnterpriseValueSSDs

    00AJ395 A577 120GBSATA2.5"MLCG3HSEnterpriseValueSSD 26

    00AJ400 A578 240GBSATA2.5"MLCG3HSEnterpriseValueSSD 26

    00FN337 AS0G 240GBSATA2.5"MLCG3HSEntrySSD 26

    00AJ405 A579 480GBSATA2.5"MLCG3HSEnterpriseValueSSD 26

    00FN342 AS0H 480GBSATA2.5"MLCG3HSEntrySSD 26

    00AJ410 A57A 800GBSATA2.5"MLCG3HSEnterpriseValueSSD 26

    00FN347 AS0J 960GBSATA2.5"MLCG3HSEntrySSD 26

    00FN278 A5U6 S35001.6TBSATA2.5"MLCG3HSEnterpriseValueSSD 26

    2.5-inchsimple-swap6GbpsSATAEnterpriseValueSSDs

    00FN475 AS5Z 960GBSATA2.5"MLCG3SSEntrySSD 16

    3.5-inchhot-swap12GbpsNLSASHDDs

    00FN188 A5VP 2TB7.2K12GbpsNLSAS3.5"G2HS512eHDD 14

    00FN208 A5VQ 4TB7.2K12GbpsNLSAS3.5"G2HS512eHDD 14

    00FN228 A5VR 6TB7.2K12GbpsNLSAS3.5"G2HS512eHDD 14

  • 7/26/2019 Tips 1193

    30/64

    Systemx3650M5 30

    Table10.Driveoptionsforinternalstorage(Part4)

    Partnumber

    Feature

    code

    Description M axim um

    suppor ted

    3.5-inchhot-swap12GbpsNLSASSEDs

    00FN238 A5VS 2TB7.2K12GbpsNLSAS3.5"G2HS512eSED 14

    00FN248 A5VT 4TB7.2K12GbpsNLSAS3.5"G2HS512eSED 14

    00FN258 A5VU 6TB7.2K12GbpsNLSAS3.5"G2HS512eSED 14

    3.5-inchhot-swap6GbpsNLSASHDDs

    90Y8572 A2U0 2TB7.2K6GbpsNLSAS3.5"G2HSHDD 14

    90Y8577 A2R2 3TB7.2K6GbpsNLSAS3.5"G2HSHDD 14

    3.5-inchhot-swap6GbpsNLSATAHDDs

    81Y9794 A22T 2TB7.2K6GbpsNLSATA3.5"G2HSHDD 14

    00FN113 A5VD 2TB7.2K6GbpsNLSATA3.5"G2HS512eHDD 14

    81Y9798 A22S 3TB7.2K6GbpsNLSATA3.5"G2HSHDD 14

    00FN128 A5VF 3TB7.2K6GbpsNLSATA3.5"G2HS512eHDD 14

    49Y6002 A3W9 4TB7.2K6GbpsNLSATA3.5"G2HSHDD 14

    00FN143 A5VH 4TB7.2K6GbpsNLSATA3.5"G2HS512eHDD 14

    00FN158 A5VK 5TB7.2K6GbpsNLSATA3.5"G2HS512eHDD 14

    00FN173 A5VM 6TB7.2K6GbpsNLSATA3.5"G2HS512eHDD 14

    3.5-inchsimple-swap6GbpsNLSATAHDDs

    81Y9810 A22W 2TB7.2K6GbpsNLSATA3.5"G2SSHDD 8

    00FN118 A5VE 2TB7.2K6GbpsNLSATA3.5"G2SS512eHDD 8

    81Y9814 A22V 3TB7.2K6GbpsNLSATA3.5"G2SSHDD 8

    00FN133 A5VG 3TB7.2K6GbpsNLSATA3.5"G2SS512eHDD 8

    49Y6012 A3WA 4TB7.2K6GbpsNLSATA3.5"G2SSHDD 8

    00FN148 A5VJ 4TB7.2K6GbpsNLSATA3.5"G2SS512eHDD 8

    00FN163 A5VL 5TB7.2K6GbpsNLSATA3.5"G2SS512eHDD 8

    00FN178 A5VN 6TB7.2K6GbpsNLSATA3.5"G2SS512eHDD 8

  • 7/26/2019 Tips 1193

    31/64

    Systemx3650M5 31

    Table10.Driveoptionsforinternalstorage(Part5)

    Partnumber

    Feature

    code

    Description M axim um

    suppor ted

    3.5-inchhot-swap6GbpsSASEnterpriseSSDs

    00AJ480 A56G S3700200GBSATA3.5"MLCHSEnterpriseSSD 14

    00AJ485 A56H S3700400GBSATA3.5"MLCHSEnterpriseSSD 14

    00AJ490 A56J S3700800GBSATA3.5"MLCHSEnterpriseSSD 14

    3.5-inchhot-swap6GbpsSATAEnterpriseValueSSDs

    00AJ435 A57F 120GBSATA3.5"MLCHSEnterpriseValueSSD 14

    00AJ440 A57G 240GBSATA3.5"MLCHSEnterpriseValueSSD 14

    00FN352 AS0K 240GBSATA3.5"MLCHSEntrySSD 14

    00AJ445 A57H 480GBSATA3.5"MLCHSEnterpriseValueSSD 14

    00FN357 AS0L 480GBSATA3.5"MLCHSEntrySSD 14

    00AJ450 A57J 800GBSATA3.5"MLCHSEnterpriseValueSSD 14

    00FN362 AS0M 960GBSATA3.5"MLCHSEntrySSD 14

    00FN288 A5U7 S35001.6TBSATA3.5"MLCHSEnterpriseValueSSD 14

    2.5-inchNVMehot-swapPCIeSSDs*

    90Y3227 A5RW P3600400GBNVMe2.5"G3HSEnterpriseValuePCIeSSD 4

    90Y3230 A5RX P3600800GBNVMe2.5"G3HSEnterpriseValuePCIeSSD 4

    90Y3233 A5RY P36001.6TBNVMe2.5"G3HSEnterpriseValuePCIeSSD 4

    90Y3236 A5RZ P36002.0TBNVMe2.5"G3HSEnterpriseValuePCIeSSD 4

    *TheinstalledoperatingsystemmustsupportNVMePCIeSSD'shot-swapcapability.

  • 7/26/2019 Tips 1193

    32/64

    Systemx3650M5 32

    Internal backup un its

    Thex3650M5serverdoesnotsupportinternaltapedriveoptionsorotherinternalbackupunits.However,itcanbeattachedtotheexternaltapedrivesusingSASorFibreChannelconnectivity(seeTable29).

    Optical dr ives

    Thex3650M5serversupportstheopticaldriveoptionslistedinTable11.Storagedensemodelswith12x3.5-inchorupto24x2.5-inchdrivebaysonthefrontdonotsupportinternalopticaldrive;asupportedexternalopticaldrivecanusedinstead.

    Table11.Opticaldrives

    Part

    number

    Feature

    code

    Descr ipt ion

    M a x im u m

    suppor ted

    Standard

    models where

    used

    00AM066 A5KG Ultraslim9.5mmSATADVD-ROM 1 -

    00AM067 A5KH Ultraslim9.5mmSATAMultiBurner 1 -

    Ultraslim9.5mmSATADVD-ROM(partnumber00AM066)supportsthefollowingmediaandspeedsforreading:

    CD-ROM24XCD-DA(DAE)24XCD-R24XCD-RW24XDVD-ROM8XDVD-R8XDVD+R8XDVD-RDL6XDVD+RDL8X

    DVD-RW8XDVD+RW8XDVD-RAM(4.7GB)5X

    Ultraslim9.5mmSATAMultiBurner(partnumber00AM067)supportsthesamemediaandspeedsforreadingasDVD-ROM(partnumber00AM066).Thisdrivealsosupportsthefollowingmediaandspeedsforwriting:

    CD-R24XCD-RW4XHighSpeedCD-RW10XUltraSpeedCD-RW24XDVD-R8XDVD+R8XDVD-RDL6XDVD+RDL6XDVD-RW6XDVD+RW8XDVD-RAM5X

  • 7/26/2019 Tips 1193

    33/64

    Systemx3650M5 33

    I /O expansion options

    TheserversupportsuptoninePCIeslots:oneslotonthesystemplanarthatisdedicatedforaninternalRAIDcontroller,tworegularPCIeslotsonthesystemplanar,anduptosixPCIeslotswithdifferentrisercardsinstalledintotworisersocketsonthesystemplanar(onerisersocketsupportsinstallationofonerisercard).Theslotformfactorsareasfollows:

    Slot0:PCIe3.0x8(dedicatedforaninternalRAIDcontroller)Slot1:PCIe3.0x16orPCIe3.0x8;full-height,full-length(PCIex16slotisdouble-wide)Slot2:PCIe3.0x8;full-height,full-length(notpresentiftheslot1isPCIex16)Slot3:PCIe3.0x8orML2;full-height,half-lengthSlot4:PCIe3.0x8;lowprofile(verticalslotonsystemplanar)Slot5:PCIe3.0x16;lowprofile(verticalslotonsystemplanar)Slot6:PCIe3.0x16orPCIe3.0x8;full-height,full-length(PCIex16slotisdouble-wide)Slot7:PCIe3.0x8;full-height,full-length(notpresentiftheslot6isPCIex16)Slot8:PCIe3.0x8;full-height,half-length

    Note:Slots5,6,7,and8requirethesecondprocessortobeinstalled.

    ThelocationsofthePCIeslotsareshowninFigure7.

    Figure7.Slotlocations

  • 7/26/2019 Tips 1193

    34/64

    Systemx3650M5 34

    Riser1suppliesslots1,2,and3,andRiser2suppliesslots6,7,and8.Standardmodelsdonotincludeanyrisercards.Table12listsavailablePCIerisercardoptions.

    Table12.PCIerisercardsandmiscellaneousoptions

    Part

    number

    Feature

    code

    Descr ipt ion

    M a x im u m

    suppor ted

    Standard

    mode ls

    where

    used

    Riser1options(suppliesslots1,2and3)

    00KA504 A5FR Systemx3650M5PCIeRiser1(1x16FH/FL+1x8ML2Slots) 1 -

    00KA519 A5FQ Systemx3650M5PCIeRiser1(2x8FH/FL+1x8ML2Slots) 1 -

    00KA489 A5FN Systemx3650M5PCIeRiser(1x16FH/FL+1x8FH/HLSlots) 1 -

    00KA498 A5FP Systemx3650M5PCIeRiser(2x8FH/FL+1x8FH/HLSlots) 1 -

    Riser2options(suppliesslots6,7and8)

    00KA489 A5R5 Systemx3650M5PCIeRiser(1x16FH/FL+1x8FH/HLSlots) 1 -

    00KA498 A5R6 Systemx3650M5PCIeRiser(2x8FH/FL+1x8FH/HLSlots) 1 -

    Serialportbracket

    00KA161 A5AN COMPortBracket 1 -

    Thermalkit

    00MU908 ASQD Systemx3650M5PCIeThermalSolutionKit 1 -

    Riseroptionpartnumbers00KA489and00KA498canbeinstalledinbothriserslots1and2;forCTOorspecialbidorderstheseoptionpartnumbershavedifferentfeaturecodesdependingontheriserslotintowhichtheyareinstalled.

    TheCOMPortBracket,partnumber00KA161,isusedformountingtheexternalserialportontherearofthex3650M5.Thisoptionincludesthebracketandthecable.TheCOMPortoptionismountedinplaceofthePCIeslot5,andthePCIeslot5cannotbeused.

    Thex3650M5ThermalKit,partnumber00MU908,containsanairbaffle.ItisrequiredwhentheIntelX540ML2DualPort10GbaseTAdapterforSystemx,partnumber00D1994,ispresentintheconfiguration.

  • 7/26/2019 Tips 1193

    35/64

    Systemx3650M5 35

    Network adapters

    Thex3650M5supportsfourintegratedGigabitEthernetports.Optionally,thex3650M5serversupportsML2adaptersthatareinstalledinthecustomML2slotprovidedbythePCIeML2risercards(partnumbers00KA504and00KA519).Thisslotsupportsadapterswitheithertwo10GbportsorfourGigabitEthernetportsandsupportsdirectconnectivitytotheIMM2serviceprocessorforout-of-bandsystems

    management.

    Theintegratednetworkinterfacecontroller(NIC)hasthefollowingfeatures:

    ABroadcomBCM5719chip

    FourGigabitEthernetports

    NICTeaming(loadbalancingandfailover)

    Ethernetfeatures:

    Compliantwith1GbEthernetIEEE802.3,802.3u,and802.3abPHYspecificationsIntegratedPHYfor10/100/1000Mbpsformultispeed,full,andhalf-duplexauto-negotiationAutomaticMDIcrossoverIEEE802.3x-compliantflowcontrolsupportIEEE1588protocoland802.1AStimesynchronizationimplementationIEEE802.3az-EnergyEfficientEthernet(EEE)

    I/OVirtualizationfeatures:

    I/OVirtualizationsupportforVMwareNetQueueandMicrosoftvirtualmachinequeue(VMQ)FunctionLevelReset(FLR)IEEE802.1qVirtualLocalAreaNetwork(VLAN)taggingsupport

    Statelessoffloadandperformancefeatures:

    TCP,IP,andUserDatagramProtocol(UDP)checksumoffloadTCPsegmentationoffload(TCO)LargeSendOffload(LSO)ReceiveSideScaling(RSS)andTransmitSideScaling(TSS)

    MessageSignalInterrupt(MSI)andMessageSignalInterruptExtension(MSI-X)supportSupportforjumboframesupto9600bytes

  • 7/26/2019 Tips 1193

    36/64

    Systemx3650M5 36

    Table13listsadditionalsupportednetworkadapters.

    Table13.Networkadapters(Part1)

    Part

    number

    Feature

    code

    Description M axim um

    suppor ted**

    40GbEthernet-ML2

    00FP650 A5RK MellanoxConnectX-3ProML22x40GbE/FDRVPIAdapterforSystemx* 1

    10GbEthernet-ML2

    00D2026 A40S BroadcomNetXtremeIIML2DualPort10GbaseTforSystemx 1

    00D2028 A40T BroadcomNetXtremeIIML2DualPort10GbESFP+forSystemx* 1

    00D1996 A40Q EmulexVFA5ML2DualPort10GbESFP+AdapterforSystemx* 1

    00D8544 A4NZ EmulexVFA5ML2FCoE/iSCSILicenseforSystemx(FoD)(FeaturesonDemandupgradefor00D1996-oneforeachadapter)

    1

    00D1994 A40P IntelX540ML2DualPort10GbaseTAdapterforSystemx 1

    94Y5200 AS74 IntelX710ML24x10GbESFP+AdapterforSystemx* 1

    1GbEthernet-ML2

    00D1998 A40R IntelI350-T4ML2QuadPortGbEAdapterforSystemx 1

    40GbEthernet/FDRInfiniBand-PCIe

    00D9550 A3PN MellanoxConnectX-340GbE/FDRIBVPIAdapterforSystemx* 4

    10GbEthernet-PCIe

    44T1370 A5GZ BroadcomNetXtreme2x10GbEBaseTAdapterforSystemx 6

    94Y5180 A4Z6 BroadcomNetXtremeDualPort10GbESFP+AdapterforSystemx* 6

    00JY820 A5UT EmulexVFA52x10GbESFP+PCIeAdapterforSystemx* 6

    00JY830 A5UU EmulexVFA52x10GbESFP+AdapterandFCoE/iSCSISWforSystemx* 6

    00JY824 A5UV EmulexVFA5FCoE/iSCSISWforPCIeAdapterforSystemx(FoD)(FeaturesonDemandupgradefor00JY820-oneforeachadapter)

    6

    49Y7960 A2EC IntelX520DualPort10GbESFP+AdapterforSystemx* 4

    49Y7970 A2ED IntelX540-T2DualPort10GBaseTAdapter 6

    81Y3520 AS73 IntelX7102x10GbESFP+AdapterforSystemx* 4

    00D9690 A3PM MellanoxConnectX-310GbEAdapterforSystemx* 4

    90Y4600 A3MR QLogic8200DualPort10GbESFP+VFAforSystemx* 6

    00Y5624 A3MT QLogic8200VFAFCoE/iSCSILicenseforSystemx(FoD)(FeaturesonDemandupgradefor90Y4600-oneforeachadapter)

    6

    47C9952 A47H SolarflareSFN5162F2x10GbESFP+PerformantAdapter* 6

  • 7/26/2019 Tips 1193

    37/64

    Systemx3650M5 37

    Table13.Networkadapters(Part2)

    Part

    number

    Feature

    code

    Description M axim um

    suppor ted**

    1GbEthernet-PCIe

    42C1780 2995 BroadcomNetXtreme2xGbEBaseTAdapter 6

    90Y9370 A2V4 BroadcomNetXtremeIDualPortGbEAdapterforSystemx 8

    90Y9352 A2V3 BroadcomNetXtremeIQuadPortGbEAdapterforSystemx 8

    00AG510 A56L IntelI350-T22xGbEBaseTAdapterforSystemx 6

    00AG520 A56M IntelI350-T44xGbEBaseTAdapterforSystemx 6

    *SFP+andQSFP+basedadaptersrequiresupportedtransceiversorDACcablesthatmustbepurchasedseparately.

    **Maximumquantityisachievedwithtwoprocessorsinstalled.Withoneprocessor,themaximumquantityishalfofthelistedvalue(thisdoesnotapplytomezzaninecards).

    Formoreinformation,seethelistofProductGuidesintheEthernetandIBadapterscategory:

    http://lenovopress.com/systemx/networkadapters

    http://lenovopress.com/systemx/networkadaptershttp://lenovopress.com/systemx/networkadapters
  • 7/26/2019 Tips 1193

    38/64

    Systemx3650M5 38

    Storage host bus adapters

    Table14listsstoragehostbusadapters(HBAs)supportedbythex3650M5server.Themaximumquantitylistedisforconfigurationswithtwoinstalledprocessors.Ifoneprocessorisinstalled,themaximumquantitysupportedishalfofthelistedvalue.

    Table14.StorageadaptersPart

    number

    Feature

    code

    Description M axim um

    suppor ted

    FibreChannel-16Gb

    81Y1675 A2XV Brocade16GbFCDual-portHBAforSystemx 8

    81Y1668 A2XU Brocade16GbFCSingle-portHBAforSystemx 8

    81Y1662 A2W6 Emulex16GbFCDual-portHBAforSystemx 8

    81Y1655 A2W5 Emulex16GbFCSingle-portHBAforSystemx 8

    00Y3337 A3KW QLogic16GbFCSingle-portHBAforSystemx 8

    00Y3341 A3KX QLogic16GbFCDual-portHBAforSystemx 8

    FibreChannel-8Gb

    46M6050 3591 Brocade8GbFCDual-portHBAforSystemx 6

    46M6049 3589 Brocade8GbFCSingle-portHBAforSystemx 8

    42D0494 3581 Emulex8GbFCDual-portHBAforSystemx 6

    42D0485 3580 Emulex8GbFCSingle-portHBAforSystemx 8

    42D0510 3579 QLogic8GbFCDual-portHBAforSystemx 8

    42D0501 3578 QLogic8GbFCSingle-portHBAforSystemx 8

    SAS

    00AE912 A5M0 N2225SAS/SATAHBAforSystemx 8

    00AE916 A5M1 N2226SAS/SATAHBAforSystemx 2

    Formoreinformation,seethelistofProductGuidesintheHostbusadapterscategory:http://lenovopress.com/systemx/hba

    http://lenovopress.com/systemx/hbahttp://lenovopress.com/systemx/hba
  • 7/26/2019 Tips 1193

    39/64

    Systemx3650M5 39

    PCIe SSD adap ters

    Thex3650M5serversupportstheHighIOPSSSDadapterslistedinTable15.

    Table15.HighIOPSPCIeSSDadapters

    Part

    number

    Feature

    code

    Descript ion M axim um

    suppor ted

    Enterprise

    00AE995 ARYP 1000GBEnterpriseio3FlashAdapterforSystemx 6

    00AE998 ARYQ 1300GBEnterpriseio3FlashAdapterforSystemx 6

    00JY001 ARYR 2600GBEnterpriseio3FlashAdapterforSystemx 6

    00JY004 ARYS 5200GBEnterpriseio3FlashAdapterforSystemx 6

    EnterpriseValue

    00AE983 ARYK 1250GBEnterpriseValueio3FlashAdapterforSystemx 6

    00AE986 ARYL 1600GBEnterpriseValueio3FlashAdapterforSystemx 6

    00AE989 ARYM 3200GBEnterpriseValueio3FlashAdapterforSystemx 6

    00AE992 ARYN 6400GBEnterpriseValueio3FlashAdapterforSystemx 6

    *TheseGPUadaptersareavailableonlythroughSpecialBidorCTO.

    Note:Theio3FlashAdapterscannotbefactoryinstalled;theyaresupportedasfield-installableoptionsonly.Theservercannotbeshippedwiththeseadaptersinstalled.

  • 7/26/2019 Tips 1193

    40/64

    Systemx3650M5 40

    GPU adapters

    Thex3650M5serversupportsagraphicsprocessingunits(GPUs)listedinTable16.

    Table16.GPUadapters

    Part

    number

    Feature

    code

    Description M axim um

    suppor ted

    None* A4G4 IntelXeonPhi3120A 2

    None* ASQJ IntelXeonPhi7120A 2

    None* AS3G NVIDIAGridK1(ActivelyCooled) 2

    None* A470 NVIDIAGridK2(ActivelyCooled) 2

    None* ASPN NVIDIAQuadroK420 4

    None* ASPP NVIDIAQuadroK620 4

    None* ASQM NVIDIAQuadroK2200 4

    None* ASQN NVIDIAQuadroK4200 2

    None* ASQP NVIDIAQuadroK5200 2

    None* A3YV NVIDIAQuadroK6000 2

    None* A471 NVIDIATeslaK20(ActivelyCooled) 2

    None* A5FG NVIDIATeslaK40c 2

    None* ASQQ NVIDIATeslaK8ActivelyCooled 4

    *TheseGPUadaptersareavailableonlythroughSpecialBidorCTO.

    ThefollowingconfigurationrulesapplyifaGPUisinstalled:

    InstallationoftwoGPUsrequirestwoprocessors.

    IftheGPUisinstalled,themaximummemorythatcanbeinstalledis1TB.

    IftheGPUisinstalled,maximumof16LRDIMMscanbeinstalled.

    Furtherrestrictionsmayapplydependingonthepowersuppliesinstalledasdescribedinthe"Powersupplies"section.

  • 7/26/2019 Tips 1193

    41/64

    Systemx3650M5 41

    Powe r suppl ies

    Thex3650M5serversupportsuptotworedundantpowersupplies.Standardmodelscomewithonepowersupply.Thefollowingtableliststhepowersupplies.

    Table17.Powersupplies

    Part

    number

    Feature

    code

    Descr ipt ion

    M a x im u m

    suppor ted

    Standard models

    where used

    00FK930 A5ET Systemx550WHighEfficiencyPlatinumACPowerSupply

    2 52x,A2x,B2x,C2x,C4x,D2x,F2x,

    00FK932 A5EU Systemx750WHighEfficiencyPlatinumACPowerSupply

    2 62x,D4x,F4x,G2x,M2x,N2x

    00FK934 A5EV Systemx750WHighEfficiencyTitaniumACPowerSupply(200-240V)

    2 -

    00FK936 A5EW Systemx900WHighEfficiencyPlatinumACPowerSupply

    2 J2x,L2x,P2x,Q2x

    00MU910 ASQF Systemx900WHighEfficiency-48VDCPowerSupply 2 -

    00MU911 ASQG Systemx1300WHighEfficiencyTitaniumACPowerSupply(200-240V)

    2 -

    00MU909 ASQE Systemx1500WHighEfficiencyPlatinumACPowerSupply

    2 -

    Generalpowersupplyrulesareasfollows:

    Minimumof1andmaximumof2powersuppliespersystem.If2areinstalled,powersuppliesmustbeidentical.

    Important:ItishighlyrecommendedtovalidateserverconfigurationforspecificpowerrequirementsusingthelatestversionoftheSystemxPowerConfigurator:http://www.ibm.com/systems/bladecenter/resources/powerconfig.html

    Thiswillensurethattherightpowersupplyischosenforoptimalperformance.

    http://www.ibm.com/systems/bladecenter/resources/powerconfig.htmlhttp://www.ibm.com/systems/bladecenter/resources/powerconfig.html
  • 7/26/2019 Tips 1193

    42/64

    Systemx3650M5 42

    Ahot-swappowersupplyoptionshipsstandardwithone2.8m,10A/100-250V,IEC320-C13toIEC320-C14rackpowercable.Othercountry-specificlinecordsandrackcablescanbeorderedifneeded(seeTable18).

    Table18.Powercables

    Part

    number

    Feature

    code

    Descr ipt ion

    Rackpowercables

    39Y7932 6263 4.3m,10A/100-250V,C13toIEC320-C14RackPowerCable

    39Y7937 6201 1.5m,10A/100-250V,C13toIEC320-C14RackPowerCable

    39Y7938 6204 IEC309C20toC13rackjumpercable

    Country-specificpowercords

    39Y7917 6212 European10AlineC13toCEE7/7(2.8M)

    39Y7918 6213 Denmark10AlineC13toDK2-5A(2.8M)

    39Y7919 6216 Switzerland10AlineC13toSEV1011(2.8M)

    39Y7920 6218 Israel10AlineC13toSI32(2.8M)

    39Y7921 6217 Italy10AlineC13toCEE7/7(2.8M)

    39Y7922 6214 SouthAfrica10AlineC13toSABS164/1(2.8M)

    39Y7923 6215 UnitedKingdom10AlineC13toBS1363(2.8M)

    39Y7924 6211 Australia/NZ10AlineC13toSAA-ASC112(2.8M)

    39Y7925 6219 Korea7AlineC13toKETI15A/250V(2.8M)

    39Y7927 6269 India6AlineC13toFig68(2.8M)

    39Y7928 6210 China6AlineC13toGB2099.1(2.8M)

    39Y7929 6223 Brazil10AlineC13toNBR6147(2.8M)

    39Y7930 6222 Argentina10AlineC13toIRAM2063(2.8M)

    39Y7931 6207 PowerCable-C13/NEMA5-15P14ft

    00CG265 A53E PowerCordTaiwanACplug10A/250V,2.8M;OPT

    00CG267 A53F PowerCordTaiwanACplug15A/125V;2.8M;OPT

    46M2592 A1RF 10A/250VC13toNEMA6-15P2.8mlinecord

    46M2593 A1RE Japan10A/100VC13toJISC-83032.8mlinecord

  • 7/26/2019 Tips 1193

    43/64

    Systemx3650M5 43

    Integrated virtualization

    TheserversupportsVMwareESXiinstalledonaUSBmemorykeyoroneortwoSDcardsintheSDMediaAdapterforSystemx.TheUSBmemorykeyisinstalledinaUSBsocketinsidetheserver.TheSDMediaAdapterisinstalledinadedicatedslotinsidetheserver.

    WhenonlyoneSDcardisinstalledintheSDMediaAdapter,youcancreateupto16volumes,eachofwhichispresentedtoUEFIasabootabledevice.WhentwoSDMediacardsareinserted,volumescanbemirrored(RAID1)acrossbothcards,uptoatotalofeightmirroredvolumes.Theuseofmirroredvolumesimprovessystemavailabilitybecausetheserverremainsoperational,evenifoneSDcardfails.TheRAIDfunctionalityishandledinternallybytheSDMediaAdapter.

    Table19liststhevirtualizationoption.

    Table19.Virtualizationoption

    Part

    number

    Feature

    code

    Descript ion M axim um

    suppor ted

    USBmemorykey

    00ML233 ASN6 USBMemoryKeyforVMwareESXi5.1Update2 1

    00ML235 ASN7 USBMemoryKeyforVMwareESXi5.5Update2 1

    41Y8298 A2G0 BlankUSBMemoryKeyforVMwareESXiDownloads 1

    00ML200 A5R7 32GBEnterpriseValueUSBMemoryKey 1

    SDMediaAdapterandSDcards

    00ML706* A5TJ SDMediaAdapter(Option00ML706includes2blank32GBSDcards) 1

    00ML700 AS2V BlankSDMediaforSystemx 2

    None** AS4B RAIDAdapterforSDMediaw/VMwareESXi5.1U2(2SDMedia,RAIDed)

    1

    None** AS4C RAIDAdapterforSDMediaw/VMwareESXi5.5U2(2SDMedia,RAIDed)

    1

    None** ASCG RAIDAdapterforSDMediaw/VMwareESXi5.1U2(1SDMedia) 1

    None** ASCH RAIDAdapterforSDMediaw/VMwareESXi5.5U2(1SDMedia) 1

    *Option00ML706includestwo32GBSDcards;however,forCTOorders,featurecodeA5TJdoesnotincludeSDmediaandthe32GBcardsandVMwarevSpherepreloadmustbeselectedseparately.**CTOonly.

    Systems management

    TheservercontainsIntegratedManagementModuleII(IMM2.1),whichprovidesadvancedservice-processorcontrol,monitoring,andanalertingfunction.Ifanenvironmentalconditionexceedsathresholdorifasystemcomponentfails,theIMM2lightsLEDstohelpyoudiagnosetheproblem,recordstheerrorintheeventlog,andalertsyoutotheproblem.Optionally,theIMM2alsoprovidesavirtualpresencecapabilityforremoteservermanagementcapabilities.

  • 7/26/2019 Tips 1193

    44/64

    Systemx3650M5 44

    TheIMMprovidesremoteservermanagementthroughindustry-standardinterfaces:

    IntelligentPlatformManagementInterface(IPMI)Version2.0SimpleNetworkManagementProtocol(SNMP)Version3CommonInformationModel(CIM)Webbrowser

    TheoptionalIntegratedManagementModuleAdvancedUpgradeisrequiredforenablingremotepresenceandblue-screencapturefeatures.Theremotepresencefeatureprovidesthefollowingfunctions:

    Remotelyviewingvideowithgraphicsresolutionsupto1600x1200at75Hzwithupto23bitsperpixelcolors,regardlessofthesystemstateRemotelyaccessingtheserverusingthekeyboardandmousefromaremoteclientMappingtheCDorDVDdrive,diskettedrive,andUSBflashdriveonaremoteclient,andmappingISOanddisketteimagefilesasvirtualdrivesthatareavailableforusebytheserverUploadingadisketteimagetotheIMMmemoryandmappingittotheserverasavirtualdrive

    Theblue-screencapturefeaturecapturesthevideodisplaycontentsbeforetheIMMrestartstheserverwhentheIMMdetectsanoperating-systemhangcondition.Asystemadministratorcanusetheblue-screencapturetoassistindeterminingthecauseofthehangcondition.Table20liststheremote

    managementoption.

    Table20.Remotemanagementoption

    Part

    number

    Feature

    code

    Description M axim um

    suppor ted

    90Y3901 A1ML IntegratedManagementModuleAdvancedUpgrade 1

    Allstandardmodelsincludebasiclightpathdiagnostics,whichincludesystemLEDsonthefrontoftheserver(SeeFigure2)andLEDsnearthemonitoredcomponents(forexample,theDIMMerrorLEDonthesystemboard).Inaddition,servermodelswitheight3.5-inchdrivebaysarestandardwithanext-genlightpathdiagnosticsLCDdisplaypanel.WithLCDdisplay,youhavequickaccesstosystemstatus,firmware,

    network,andhealthinformation.Standardmodelswitheightorsixteen2.5-inchdrivebaysandbasiclightpathcanbeupgradedtoanext-genlightpathLCDpanel.Also,Configure-to-order(CTO)customersmayconfigureanLCDdisplaypanelfortheirfactory-builtmodels.Table21showstheLCDdisplaypanelorderinginformation.

    Table21.Lightpathdiagnosticsoption

    Part

    number

    Feature

    code

    Descr ipt ion

    M a x im u m

    suppor ted

    Standard models

    where used

    00KA503 A4VH Systemx3650M5AdvancedLCDLightPathKit 1 B2x,C4x,N2x,P2x,Q2x

    Thefollowingx3650M5ExpressmodelshavetheLightPathLCDDisplayPanelasstandard:E1G,E2G,

    E3G,E4G,E5G,E6G,E7J,E8J,E9J,EAU,EBU,ECU,EDU,EEU,EFU,EGU,EHM,EIM,EJM,EKM,ELM,EMM,ENU,EOU,EPU,EQU,ERU,andESU.

    Thefollowingx3650M5TopSellermodelshavetheLightPathLCDDisplayPanelasstandard:NAU,NBU,NCU,NDU,NEU,NFU,NHU,NJU,NJG,NKU,NMU,NNU,NPU,NPG,E0U,ETU,EUU,EVU,EWU,EXU,EYU,andEZU.

  • 7/26/2019 Tips 1193

    45/64

    Systemx3650M5 45

    IBMSecurityKeyLifecycleManagerforSystemxSEDs-FoD(SKLM-FoD)isanoptionalfeature,availableinSystemxenvironments,thatcentralizes,simplifies,andautomatesthedataencryptionkeymanagementprocesstohelpminimizeriskandreduceoperationalcosts.SKLM-FoDoffersasimpleandrobustsolutionforkeystorage,keyserving,andkeylifecyclemanagementforself-encryptingdrives(SEDs)inlocalanddistributedSystemxenvironments.Withthex3650M5,theFeatureonDemand(FoD)upgradecanbeconfiguredwiththeServeRAIDM5210andM1215RAIDcontrollerspairedwithSEDs.Table22listsSKLM-FoDpartnumbers.

    Table22.SecurityKeyLifecycleManager-FoDpartnumbers

    Part

    number

    Feature

    code

    Description M axim um

    suppor ted

    UnitedStates,Canada,AsiaPacificandJapan

    00D9998 A5U1 IBMSKLMforSystemxw/SEDs-FoDperInstallw/1YrS&S 1

    00D9999 AS6C IBMSKLMforSystemxw/SEDs-FoDperInstallw/3YrS&S 1

    LatinAmerica,Europe,MiddleEastandAfrica

    00FP648 A5U1 IBMSKLMforSystemxw/SEDs-FoDperInstallw/1YrS&S 1

    00FP649 AS6C IBMSKLMforSystemxw/SEDs-FoDperInstallw/3YrS&S 1

    Operat ing systems

    Theserversupportsthefollowingoperatingsystems:

    Microsoft:

    MicrosoftWindowsServer2012R2MicrosoftWindowsServer2012MicrosoftWindowsServer2008R2

    RedHat:

    RedHatEnterpriseLinux7RedHatEnterpriseLinux6Serverx64Edition(Update5)

    SUSE:

    SUSELinuxEnterpriseServer12SUSELinuxEnterpriseServer12withXenSUSELinuxEnterpriseServer11forAMD64/EM64T(SP3)SUSELinuxEnterpriseServer11withXenforAMD64/EM64T(SP3)

    VMware:

    VMwarevSphere5.5(ESXi)(Update2)VMwarevSphere5.1(ESXi)(Update2)

    SeetheServerProvenwebsiteforthelatestinformationaboutthespecificversionsandservicelevelssupportedandanyotherprerequisites:http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml

    http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtmlhttp://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml
  • 7/26/2019 Tips 1193

    46/64

    Systemx3650M5 46

    Physical and electrical specifications

    Dimensionsandweight(approximate):

    Height:86.5mm(3.4in.)Width:445.6mm(17.5in.)

    Depth:800mm(31.5in.)

    Weight:

    Minimumconfiguration:19kg(42lb)Maximumconfiguration:34kg(75lb)

    Supportedenvironment:

    Airtemperature:

    Serveron:5Cto40C(41Fto104F);altitude:0to950m(3,117ft);decreasethemaximumsystemtemperatureby1Cforevery175-mincreaseinaltitudeabove950m.Serveroff:5Cto45C(41Fto113F)Maximumaltitude:3,050m(10,000ft),5Cto28C(41Fto82F)Shipment:-40Cto+60C(-40Fto140F)atupto10,700m(35,105ft)

    Humidity:

    Serveron:8%to85%,maximumdewpoint24C,maximumrateofchange5C/hrServeroff:8%to85%,maximumdewpoint27C

    DesigntoASHRAEClassA3,ambientof36Cto40C(96.8Fto104F),withrelaxedsupport:

    Supportscloud-likeworkloadwithnoperformancedegradationacceptable(Turbo-Off).Undernocircumstancecananycombinationofworst-caseworkloadandconfigurationresultinsystemshutdownordesignexposureat40C.Theworst-caseworkload(likeLinpack,Turbo-On)mighthaveperformancedegradation.

    Electrical:

    Modelswith1500WPlatinumpowersupplies:

    200-240(nominal)Vac;50Hzor60Hz;8.35AInputkilovolt-amperes(kVA)(approximately):

    Minimumconfiguration:0.15kVAMaximumconfiguration:1.967kVA

    Modelswith1300WTitaniumpowersupplies:

    200-240(nominal)Vac;50Hzor60Hz;7.137AInputkilovolt-amperes(kVA)(approximately):

    Minimumconfiguration:0.15kVAMaximumconfiguration:1.700kVA

    Modelswith900WACpowersupplies:

    100to127(nominal)Vac;50Hzor60Hz;10.3A200to240(nominal)Vac;50Hzor60Hz;5.0AInputkilovolt-amperes(kVA)(approximately):

    Minimumconfiguration:0.15kVAMaximumconfiguration:1.194kVA

  • 7/26/2019 Tips 1193

    47/64

    Systemx3650M5 47

    Modelswith750WPlatinumACpowersupplies:

    100to127(nominal)Vac;50Hzor60Hz;8.6A200to240(nominal)Vac;50Hzor60Hz;4.2AInputkilovolt-amperes(kVA)(approximately):

    Minimumconfiguration:0.15kVAMaximumconfiguration:1.015kVA

    Modelswith750WTitaniumACpowersupplies:

    200to240(nominal)Vac;50Hzor60Hz;4.2AInputkilovolt-amperes(kVA)(approximately):

    Minimumconfiguration:0.15kVAMaximumconfiguration:0.965kVA

    Modelswith550WACpowersupplies:

    100to127(nominal)Vac;50Hzor60Hz;6.5A200to240(nominal)Vac;50Hzor60Hz;3.3AInputkilovolt-amperes(kVA)(approximately):

    Minimumconfiguration:0.16kVAMaximumconfiguration:0.732kVA

    Modelswith-48Vdc900Wpowersupplies:

    -48--60(nominal)Vdc;25.8AInputkilovolt-amperes(kVA)(approximately):

    Minimumconfiguration:0.15kVAMaximumconfiguration:1.237kVA

    BTUoutput:

    Minimumconfiguration:525Btu/hr(154watts)Maximumconfiguration:6667Btu/hr(1954watts)

    Noiselevel:

    6.6bels(operating)6.4bels(idle)

  • 7/26/2019 Tips 1193

    48/64

    Systemx3650M5 48

    Warranty options

    TheSystemx3650M5

    hasathree-yearwarrantywith24x7standardcallcentersupportand9x5NextBusinessDayonsitecoverage.AlsoavailableareLenovoServiceswarrantymaintenanceupgradesandpost-warrantymaintenanceagreements,withawell-definedscopeofservices,includingservicehours,responsetime,termofservice,andserviceagreementtermsandconditions.

    Lenovowarrantyserviceupgradeofferingsarecountry-specific.Notallwarrantyserviceupgradesareavailableineverycountry.FormoreinformationaboutLenovowarrantyserviceupgradeofferingsthatareavailableinyourcountry,visittheLenovoServiceswebsite:

    https://www-304.ibm.com/sales/gss/download/spst/servicepac

    Thefollowingtableexplainswarrantyservicedefinitionsinmoredetail.

    Table23.Warrantyservicedefinitions

    Term Description

    On-site

    service

    Aservicetechnicianwillarriveattheclientslocationforequipmentservice.

    24x7x2hour Aservicetechnicianisscheduledtoarriveattheclientslocationwithintwohoursafterremoteproblemdeterminationiscompleted.Lenovoprovidesservicearoundtheclock,everyday,includingLenovoholidays.

    24x7x4hour Aservicetechnicianisscheduledtoarriveattheclientslocationwithinfourhoursafterremoteproblemdeterminationiscompleted.Lenovoprovidesservicearoundtheclock,everyday,includingLenovoholidays.

    9x5x4hour Aservicetechnicianisscheduledtoarriveattheclientslocationwithinfourbusinesshoursafterremoteproblemdeterminationiscompleted.Lenovoprovidesservice8:00am-5:00pmintheclient'slocaltimezone,Monday-Friday,excludingLenovoholidays.Forexample,ifacustomerreportsanincidentat3:00pmonFriday,thetechnicianwillarriveby10:00amthefollowingMonday.

    9x5nextbusinessday

    Aservicetechnicianisscheduledtoarriveattheclientslocationonthebusinessdayafterremoteproblemdeterminationiscompleted.Lenovoprovidesservice8:00am-5:00pmintheclient'slocaltimezone,Monday-Friday,excludingLenovoholidays.Callsreceivedafter4:00pmlocaltimerequireanextrabusinessdayforservicedispatch.Nextbusinessdayserviceisnotguaranteed.

    CommittedRepair

    Problemsreceivepriorityhandlingsothatrepairsarecompletedwithinthecommittedtimeof6,8,or24hours.Lenovoprovidesservice24hours/day,everyday,includingLenovoholidays.

    https://www-304.ibm.com/sales/gss/download/spst/servicepachttps://www-304.ibm.com/sales/gss/download/spst/servicepac
  • 7/26/2019 Tips 1193

    49/64

    Systemx3650M5 49

    ThefollowingLenovowarrantyserviceupgradesareavailable:

    Warrantyandmaintenanceserviceupgrades:

    Three,four,orfiveyearsof9x5or24x7servicecoverageOnsiteresponsefromnextbusinessdayto2or4hoursCommittedrepairservice

    Warrantyextensionofupto5yearsPostwarrantyextensions

    CommittedRepairService

    CommittedRepairServicesenhancesthelevelofWarrantyServiceUpgradeorPostWarranty/MaintenanceServiceofferingassociatedwiththeselectedsystems.Offeringsvaryandareavailableinselectcountries.

    Priorityhandlingtomeetdefinedtimeframestorestorethefailingmachinetogoodworkingcondition

    Committedrepairservicelevelsaremeasuredwithinthefollowingcoveragehours:

    24x7x6:Serviceperformed24hoursperday,7daysperweek,within6hours24x7x8:Serviceperformed24hoursperday,7daysperweek,within8hours

    24x7x24:Serviceperformed24hoursperday,7daysperweek,within24hours

    HardDriveRetention

    LenovosHardDriveRetentionserviceisamulti-driveharddriveretentionofferingthatensuresyourdataisalwaysunderyourcontrol,regardlessofthenumberofharddrivesthatareinstalledinyourLenovoserver.Intheunlikelyeventofaharddrivefailure,youretainpossessionofyourharddrivewhileLenovoreplacesthefaileddrivepart.Yourdatastayssafelyonyourpremises,inyourhands.TheHardDriveRetentionservicecanbepurchasedinconvenientbundleswithourwarrantyupgradesandextensions.

    MicrocodeSupport

    Keepingmicrocodecurrenthelpspreventhardwarefailuresandsecurityexposure.Therearetwolevelsofservice:analysisoftheinstalledbaseandanalysisandupdatewhererequired.Offerings

    varybycountryandcanbebundledwithotherwarrantyupgradesandextensions.

    RemoteTechnicalSupportServices(RTS)

    RTSprovidescomprehensivetechnicalcallcentersupportforcoveredservers,storage,operatingsystems,andapplications.Providingasinglesourceforsupportofhardwareandsoftwareissues,RTScanreduceproblemresolutiontime,decreasingthecosttoaddresstechnicalproblemsandincreasinguptime.OfferingsareavailableforWindows,Linux,IBMSystemsDirector,VMware,Microsoftbusinessapplications,andLenovoSystemxstoragedevices,andIBMOEMstoragedevices.

  • 7/26/2019 Tips 1193

    50/64

    Systemx3650M5 50

    Regulatory compliance

    Theserverconformstothefollowingregulations:

    FCC-VerifiedtocomplywithPart15oftheFCCRules,ClassACanadaICES-003,issue5,ClassA

    UL/IEC60950-1

    CSAC22.2No.60950-1NOM-019ArgentinaIEC60950-1JapanVCCI,ClassAAustralia/NewZealandAS/NZSCISPR22,ClassA;AS/NZS60950.1ChinaCCCGB4943.1,GB9254ClassA,GB17625.1TaiwanBSMICNS13438,ClassA;CNS14336-1KoreaKN22,ClassA;KN24Russia,BelorussiaandKazakhstan,TRCU020/2011(forEMC)andTRCU004/2011(forsafety)IEC60950-1(CBCertificateandCBTestReport)CEMark(