73
1 Timber Framing Code. INTRO TO ROOFING and PRELIMINARY CALCULATIONS

Timber Framing Code

Embed Size (px)

DESCRIPTION

Timber Framing Code. INTRO TO ROOFING and PRELIMINARY CALCULATIONS. Previously. We looked at the subject in general Discussed assessment criteria Section 1. Scope & General Section 2. Terminology & definitions. Section 7. Roof Framing. Flowchart. - PowerPoint PPT Presentation

Citation preview

Page 1: Timber Framing Code

1

Timber Framing Code.

INTRO TO ROOFING and PRELIMINARY

CALCULATIONS

Page 2: Timber Framing Code

2

Previously.

We looked at the subject in general Discussed assessment criteria Section 1. Scope & General Section 2. Terminology & definitions. Section 7. Roof Framing

Page 3: Timber Framing Code

3

Flowchart It is recommended that design starts

at the roof and works down to the foundation.

Although the flowchart on page 17 tells us to-

1. Determine wind classification.2. Consider the bracing and tie-down

details. We will leave wind classification to the

structures teachers Consider bracing details after roof and

wall design.

Page 4: Timber Framing Code

4

Revision Quiz

1.   AS 1684 specifies the requirements for building practices for what classes of building?

Page 5: Timber Framing Code

5

2.  List 5 limitations on building design using AS 1684

 

Page 6: Timber Framing Code

6

4.   Why is it necessary to determine the wind classification of a

site prior to using AS 1684 to select section sizes of members?

  

Page 7: Timber Framing Code

7

5.   A site may be classified as N1, N2, N3, N4, C1, C2, C3 or C4.

 a.   What do the letters N and C

indicate? b. True or false : The higher the number the greater the wind risk

Page 8: Timber Framing Code

8

6.   What are racking forces and how are they resisted?

 

Page 9: Timber Framing Code

9

7.   How are overturning forces resisted?

Page 10: Timber Framing Code

10

10. The amount of ‘bearing’ of a member is…….?

Page 11: Timber Framing Code

11

11. What is stress grading and how is it achieved?

Page 12: Timber Framing Code

12

Let’s start. Remember- throughout this module

we will consider Coupled roofs With single row of underpurlin. Without ridge struts

Page 13: Timber Framing Code

13

Roof (and ceiling) Members

Ceiling joists Hanging beams Counter beams Strutting beams Combined strutting/hanging beams Combined counter/hanging beams Underpurlin

Page 14: Timber Framing Code

14

Roof Members cont’d

RaftersHipsRidges Valleys

Page 15: Timber Framing Code

15

CalculationsIf you look at the supplement tables you see that you need to determine

Spacing of members Spans- single or continuous Ceiling load widths CLW Roof area supported Roof load widths RLW Rafter span Rafter overhang

Page 16: Timber Framing Code

16

Calculations Spacing of members such as ceiling

joists are measured centre to centre or “in to over"

Page 17: Timber Framing Code

17

Member sizes Remember: The flow chart dictates that we first- Determine the wind classification Consider position and extent of wind bracing

and tie downs

Let us assume-1. That wind classification for all our exercises

is N32. There is sufficient room for bracing and tie-

downs

Page 18: Timber Framing Code

18

Preliminary calculations Some calculations are required before

we have sufficient data to use the span tables

Page 19: Timber Framing Code

19

Preliminary calculations You MUST have a scientific calculator. You only need to be able to do very

basic trigonometry. You must be able to use Pythagoras

theorem. You need to be able to perform basic

algebra

Page 20: Timber Framing Code

20

Preliminary calculations

What do we mean by the term ‘true length of rafter’?

We need to be able to calculate the true length of the rafter so that we can determine such things as-

The span of the common rafter RLW Rafter overhangs Areas supported

Page 21: Timber Framing Code

21

Trigonometry Comes from the Greek words ‘Trigon’

meaning triangle and ‘metre’ meaning to measure.

Trigonometry is based on right angled (900 )

triangles. It involves finding an unknown length or angle,

given that we know a length or an angle or various combination of known and unknown data.

We will also use the “Pythagoras” theorem

Page 22: Timber Framing Code

22

Trig ratios The 3 basic trig ratios are Sine (sin) Cosine (cos) Tangent (tan)

Page 23: Timber Framing Code

23

Trigonometry The ratios are related to parts of the

right angled triangle The ‘Hypotenuse’ is always the longest

side and is opposite the right angle. The other two sides are either the

‘opposite’ or the ‘adjacent’ depending on which angle is being considered.

Page 24: Timber Framing Code

24

Trigonometry Sin =opposite ÷ hypotenuse Cos = adjacent ÷ hypotenuse Tan = opposite ÷ adjacent

OR S= O÷H C= A÷H T= O÷A

Page 25: Timber Framing Code

25

TrigonometrySome students remember this byforming the words- SOH CAH TOA Or by remembering Some Old Hounds Can’t Always Hide Their Old Age

Page 26: Timber Framing Code

26

The Pythagoras theorem The square on the hypotenuse

equals the sum of the squares on the other two sides.

Or A2 = b2 + c2

Page 27: Timber Framing Code

27

Roofing calculations. If we know the roof pitch. And the run of the rafter. We will use the term RUN of rafter

rather than half span. We can use trigonometry and

Pythagoras to find the true length of the rafter

And it’s overhang.

Page 28: Timber Framing Code

True length of the common Rafter

28

overhang

underpurlinOutside edge of top plate Rafter length

Run of rafter

Centre of ridge

Rise of roof

Page 29: Timber Framing Code

29

NOTE! We are not calculating an ordering

length. We require the length from ridge to

birdsmouth. You may know this as the set out length We need to find the Eaves overhang

separately

Page 30: Timber Framing Code

30

Problem

Calculate the true length of the rafter Pitch is 270

Run of rafter is 4000

Page 31: Timber Framing Code

31

Example:Method 1. (using Tan) Trade students may be more comfortable with

this method Find the Rise per metre of C.Raft Find the True length per metre of C.Raft Multiply TLPM x Run= True length of rafter.

Page 32: Timber Framing Code

32

Method 1. (using Tan)

Rise per metre run = Tan 270

= 0.5095= 0.510

T.L. per metre CR = √ R2 + 12

= √ 0.5102 + 12

= √ 1.260= 1.122m

T.L.C.R. = T.L per metre X run= 1.122x 4.0= 4.489m

Page 33: Timber Framing Code

33

Method 2. Using Cosine (Cos)

Pitch is 270

The run is 4.0m

Cos 270 = adjacent ÷ hypotenuse= run ÷ rafter length

Rafter length = run ÷ cos 270

= 4.0 ÷ 0.8910= 4.489m

Page 34: Timber Framing Code

34

Exercises Calculate the following rafter lengths.

(choose either method) Pitch 370 , Run 3.750m 4.696m Pitch 230 , Run 4.670m 5.073m Pitch 19.50 , Run 2.550m 2.705m

Page 35: Timber Framing Code

35

True length of eaves overhang.

Firstly you must be aware of the difference between eave width and eaves overhang.

For a brick veneer building with an eaves width of 450mm; the actual width to the timber frame is 450 + 150mm for brick and cavity = 600mm

Page 36: Timber Framing Code

36

Page 37: Timber Framing Code

37

True length of eaves overhang.

The true length of the eaves overhang is the measurement ‘on the rake’ from the ‘x y’ line to the back of the fascia along the top edge of the rafter.

It can be calculated the same way you calculate you calculated the rafter length

Page 38: Timber Framing Code

True length of the common Rafter

38

overhang

underpurlinOutside edge of top plate Rafter length

Run of rafter

Centre of ridge

Rise of roof

Page 39: Timber Framing Code

39

Student exercises 2. Calculate the true length of eaves overhang

for each of the following (all brick veneer) Pitch 270, eaves width 450mm .673m Pitch 370 , eaves width 500mm .814m Pitch 230 , eaves width 480mm .684m

Page 40: Timber Framing Code

40

Span of the common rafter. The ‘Span of the rafter’ is the actual

distance on the rake between points of support.

Page 41: Timber Framing Code

Span of the common Rafter

41

overhang

span

spanCentre of underpurlin

Outside edge of top plate

Page 42: Timber Framing Code

42

Span of the common rafter. Span of rafter is the true length of the

rafter divided by 2 That is:- from our previous example

= 4.489 ÷ 2= 2.245m

Page 43: Timber Framing Code

43

Student exercises 3. Calculate the span of the common rafter

for the 3 roof pitches from previous exercise.

Page 44: Timber Framing Code

44

Exercises (calculate span) Pitch 370 , Run 3.750m 4.696m / 2 = 2.348m Pitch 230 , Run 4.670m 5.073m / 2 = 2.537m Pitch 19.50 , Run 2.550m 2.705m / 2 = 1.353m

Page 45: Timber Framing Code

45

Fan struts We can make more economical use of

underpurlin by using fan struts. The fan strut does not increase the

allowable span of the underpurlin. It enables the points of support (walls or

strutting beams) to be further apart

Page 46: Timber Framing Code

46

Fan struts To estimate the spread of the fan strut

we make 3 assumptions1. The underpurlin is in the centre of the

rafter length.2. The plane of the fan strut is fixed

perpendicular to the rafter.3. The fans are at 450

Page 47: Timber Framing Code

47

Page 48: Timber Framing Code

48

Page 49: Timber Framing Code

49

Page 50: Timber Framing Code

50

Page 51: Timber Framing Code

51

U n d e r p u r l i n

M i n . a n g l e 6 0t o h o r iz o n t a l

o

E a c h s t r u t 3 0 m m m i n .b e a r in g to t o p p l a te S t i f f e n e r

C h o c k n a i l e d t o p l a te

E q u a l a n g le s n o tle s s th a n 4 5 o

9 0 x 3 5 m m s p r e a d e r c le a t s e i th e r s id e o f s t r u t s f i x e d w i th M 1 2 t h r o u g h b e l t

S t ru t n a i le d to u n d e r p u r l in w i t h 4 / 7 5 m m n a i ls

S t r u t s ( s e e Ta b le 7 .5 )

Page 52: Timber Framing Code

52

Fan Struts

45O max.45O max.

EQUAL

60O max. 45O max.45O max.

EQUAL

60O max.

Page 53: Timber Framing Code

53

Fan struts (use Tan) The formula is- ½ spread of the fan struts= Span of rafter x tan angle of pitch For our previous example = 2.245 x 0.510 (tan 27 deg.) = 1.142m

Page 54: Timber Framing Code

54

Fan struts Therefore distance apart of strutting

points for a given u/purlin can be increased by 1.142m using a fan strut at one end of the underpurlin span.

Distance apart of strutting points can be increased by 2.284m using a fan strut at both ends of the underpurlin span.

Page 55: Timber Framing Code

55

Supplement Tables

Once the preliminary calculations have been done we can start to use the span tables in the supplement

But which supplement????

Page 56: Timber Framing Code

56

Using supplement tables Firstly you must choose the correct

supplement (see page 3 of the standard)

Depends on wind classification, stress grade and species of timber

Then choose the applicable table within the supplement (see list of tables page 3 of the supplement)

Page 57: Timber Framing Code

57

Class Exercise - N3 wind classification Using MGP 15 seasoned softwood Single storey building Tile roof Roof load width 3.000m Rafter spacing 600mm Select a lintel size to span 2100m

Page 58: Timber Framing Code

58

Class Exercise- Which supplement? 6 Which table? 18

Page 59: Timber Framing Code

59

Page 60: Timber Framing Code

60

Class Exercise- Choose one of these 2/120x45 ? 2/140x35 170x35 ? Which one is the smallest cross section? But is this section commercially available?

Page 61: Timber Framing Code

61

Class Exercise- Notice that in the last exercise the RLW,

Rafter spacing and required span of lintel were all values included in the table.

What if the RLW is 3300 or the rafters are spaced at 500mm or the lintel needs to span 2.250m?

WE need to INTERPOLATE

Page 62: Timber Framing Code

62

Interpolation Simply put, to interpolate is ‘To estimate a

value between known values’. It is not possible to show every span or

spacing related to member sizes. Convenient regular increments are used. Linear interpolation is allowed for

calculation of intermediate values.

Page 63: Timber Framing Code

63

Cross multiplication Before we start doing interpolation

calcs. You need to be conversant with a

mathematical procedure called cross multiplication.

Page 64: Timber Framing Code

64

Cross multiplication In an “equation” such as A = C

B D we can cross multiply so that A x D = B x C Same as the ration A:B::C:D

Page 65: Timber Framing Code

65

Class Exercise If RLW is now 3.300 Rafters still at 600 Required span 2.100

We need to interpolate between two columns to find the most economical section size.

Page 66: Timber Framing Code

66

Class Exercise Run your fingers down the 3000m

column and the 4500m column for 600 spacing.

We can tell that 2/140x35 will probably span.

Page 67: Timber Framing Code

67

Page 68: Timber Framing Code

68

Class ExerciseRLW RLW RLW3000 3300 4500

2300 ? 2000

Page 69: Timber Framing Code

69

Class ExerciseRLW RLW RLW3000 3300 4500

2300 2240 2000

Page 70: Timber Framing Code

70

Class exercise Using Table 18 of supplement 6 Interpolate to find the maximum

allowable span for a 290x45 lintel RLW 5300 Spacing of rafters 1200mm

Page 71: Timber Framing Code

71

Class ExerciseRLW RLW RLW4500 5300 6000

3400 ? 3100

Page 72: Timber Framing Code

72

Class ExerciseRLW RLW RLW4500 5300 6000

3400 3240 3100

Page 73: Timber Framing Code

73

Next week

We will start work on selecting suitable roofing members from a given plan and specification