14
Application of Phase Change Materials in Cold Chain Transport thermoTab active -Enabling last mile connectivity with fuel free refrigeration.

thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

Application of Phase Change Materials in Cold Chain Transport

thermoTab active -Enabling last mile connectivity with fuel free refrigeration.

Page 2: thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

The cold chain logistics infrastructure

Overview

Refrigerated transportation is required to carry temperature sensitive food/medicine at every step

Supply / Procurement

Precooling System Farms

(Rural Market) Manufacturer

Transport

Refrigerated Trucks

Refrigerated Railway Wagons

Refrigerated Cargo Containers

Storage

Cold Storage

Warehouses Perishable

Holding Center

Transport

Refrigerated Trucks

Refrigerated Railway Wagons

Refrigerated Cargo Containers

End Customer

Retail Terminal Markets Factory Ports Airport

Page 3: thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

Current Challenges - Temperature Controlled Transportation

Limited distribution radius without temperature control

Ideal

Current

High maintenance & operational costs of conventional cold chain logistic solutions

“In 2015, India’s infrastructure gap in reefer transport was assessed at 52,826 units; the country is estimated to have only 9000-10000 long haul reefer trucks and zero reefer containers in use.” Extracted from NCCD - AICIC study

Page 4: thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

Different F&V products require different temperature range

Current Challenges - Temperature Controlled Transportation

Spoilage due to poor or no temperature control

-18 to -20°C 2 to 8°C 15 to 25°C

“Cold-chain development must shift from the past focus on cold storage alone, towards a supply chain based approach. The cold-chain needs to function as a conduit that communicates farm produce, at the right temperature, to multiple terminal markets. This approach will be crucial for doubling of farmers income, to bring farm productivity to gainful use and to have a future ready food supply system.” – Pawanexh Kohli, NCCD

Page 5: thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

thermoTab™active – Enabling fuel free refrigeration for logistics and PLUSS in collaboration with FIC, Italy, offers an innovative solution for temperature controlled logistic

solution to enable temperature controlled transport of food and beverages.

thermoTab active PCM plates

Page 6: thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

About thermoTab active

An innovative solution for temperature controlled logistics.

Enables the transport of temperature sensitive food and beverages without any need for active diesel run refrigeration system.

Made up of two sheets of mild steel, cold formed and welded together through electrical resistance.

External surface covered with a thin layer of zinc while into the plate is the Phase Change Material.

An evaporator coil, made up of mild-steel, is positioned into the plate that allows freezing of the phase changing solution.

Segmented into two broad categories on the basis of applications: Chilled (2oC to 8oC) and Frozen (-25oC to -18oC).

Page 7: thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

Pluss® PCM

Maintains constant temperature utilizing the latent heat.

Thermal Management to increase efficiency.

Shifts peak power loads to off-peak hour.

Reliable temperature backup.

Re-usable for more than 2000 thermal cycles.

Green technology - Environment friendly.

Page 8: thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

Range and Specification

S. No Model External Dimension

(mm) Total Weight /plate

(kg) Energy Extraction / plate

(kWh)

1 Thermotab active 1250F 1190 x 485 x 54 46.5 2.03

2 Thermotab active 1370F 1290 x 690 x 49 64.5 2.54

1. Frozen (-15 to -25OC)

S. No Model External Dimension

(mm) Total Weight /plate

(kg) Energy Extraction / plate

(kWh)

1 Thermotab active 1250C 1190 x 485 x 54 39.5 1.71

2 Thermotab active 1370C 1290 x 690 x 49 55.5 2.50

2. Chilled (2 to 8OC)

Page 9: thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

Advantages of thermoTab active over conventional systems

thermoTab active System Forced Cooling (Conventional) System

• No moving parts involved throughout the operation • Continuous running of evaporator fan and compressor

• Low servicing cost • Higher servicing cost involved

• Lasts as long as the truck itself • Life of such a system is ̴ 5yrs

• No skilled personnel required • Skilled personnel required for its servicing

• Product is continuously cooled even if truck breaks down • Product safety hampered if truck breaks down

• Non polluting product- no exhaust generated • Air Pollution due to continuous exhaust

• No noise generation • High levels of noise generated

Page 10: thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

How selection is done?

Understanding the

heat load

1

Sizing the refrigeration

capacity

Selection of

thermoTab™active

plate

2

3

Page 11: thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

Performance & Temperature Validation

Disclaimer: All Trial results are obtained under standard conditions

-30

-20

-10

0

10

20

30

40

10:26:24 AM 2:31:12 PM 6:36:00 PM 10:40:48 PM

Tem

pe

ratu

re (

De

g C

)

Time

Frozen Application

Ambient Temperature Internal Temperature

0

5

10

15

20

25

30

35

40

10:26:24 AM 2:31:12 PM 6:36:00 PM 10:40:48 PM

Tem

pe

ratu

re (

De

g C

)

Time

Chilled Application

Ambient Temperature Internal Temperature

Page 12: thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

Cost Benefit Analysis

*Based on assumptions for 12 hours operation per day in TATA 407

Parameter Chilled Frozen

Payback Period (year) < 1 < 1

Annual Saving (INR lakhs) 4.2 5.1

0.0

5.0

10.0

15.0

20.0

25.0

Diesel Operated thermotab®active

Chilled

Co

st (

INR

Lak

hs)

First year cost for Chilled Application*

Initial Cost Running Cost/year

0.0

5.0

10.0

15.0

20.0

25.0

30.0

Diesel Operated thermotab®active

Frozeen

Co

st (

INR

Lak

hs)

First year cost of Frozen Application*

Initial Cost Running Cost/year

Frozen

11lakhs 11.8 lakhs

7.7 lakhs 12 lakhs

15.8 lakhs

8.7 lakhs 13.8 lakhs

13 lakhs

Page 13: thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

Parameters Without PCM With PCM

Remarks Rs. Lacs Rs. Lacs

Initial cost

Cost of Truck 7 7 For TATA 407 Vehicle ( 8ft x 6ft x 6ft)

Total cost of PCM-Eutectic Plates to be required 1.50 5 nos. of thermoTab™ active 1250C for 2°C and 12 hours backup

Truck Body 1.5 1.50 Actual quotes from supplier and customer inputs

Diesel Refrigeration unit cost 2.5 Inputs from customer

Condensing unit for charging plates 1.75 Including installation charges as Rs. 15000

Total Capital Cost 11.00 11.75

Operating cost

Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer

Per Day (12 hour), Liters 48 30

Diesel Cost Per annum (12 hrs. x365 days) 11.388 7.1175

Electricity Cost per day 0.001 Rs.6 per unit x 10 units (required to charge PCM plates)

Electricity Cost per annum to charge the PCM Plates 0.219

Any other costs - Maintenance etc. 0.569 0.367 5% of the running cost

Total Running Cost per annum 11.96 7.70

Savings

Investment in Capital cost 0.75 Lacs (difference between Refrigeration system and PCM cost)

Annual Savings using PCM system per truck 4.25 Lacs (difference in their running cost)

Payback Period 3-4 months Including any other extra expenses

Sample Case Study: Cost Benefit Analysis for Chilled Variant Reefer Truck

Page 14: thermoTab active - PureTemp LLC€¦ · Diesel Consumption for the vehicle ,Liters per hour 4 2.5 Source: Case study for refrigerated trucks & Data obtained from customer Per Day

Thank You