6
Respecting the biological distance horizontal offset of the biological distance to help keep the microgap away from the bone Optimal position of smooth and rough surface maximize osseointegration and crestal bone preservation with the SLActive TM surface to the top THE STRAUMANN ® BONE LEVEL IMPLANT gives you full treatment confidence, designed to preserve crestal bone through the unique Bone Control Design TM , provides excellent esthetic outcomes through Consistent Emergence Profiles TM , and simplifies handling with the CrossFit TM Connection. The Straumann ® Bone Level Implant offers you the following benefits: ß High confidence and treatment predictability thanks to SLActive TM – the surface with success built in. TM ß Minimal tissue trauma from start to finish, providing superb esthetic results ß Same procedures and instruments for all Straumann dental implants SUPERB CRESTAL BONE PRESERVATION THROUGH BONE CONTROL DESIGN TM Microgap control conical connection designed to provide bacterial seal and minimize sensitivity to lateral forces Implant surface osseoconductivity increased treatment predictability and confidence with SLActive TM surface* Biomechanical implant design excellent fatigue strength and optimized force transmission Straumann developed Bone Control Design TM based on five fundamental biological principles to maximize crestal bone preservation and soft tissue stability. * as compared to SLA ® Bone Control Design TM Designed to optimize crestal bone preservation by adherence to biological principles Consistent Emergence Profiles TM Experience simplifed soft tissue management from start to finish CrossFit TM Connection Feel the fit of the self-guiding connection "The tissue is the issue but the bone sets the tone." 5 – Dr. D. Garber

THE STraumann BonE LEvEL ImpLanT - Toledo Perio

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: THE STraumann BonE LEvEL ImpLanT - Toledo Perio

Respecting the biological distance

horizontal offset of the biological distance to help keep the microgapaway from the bone

Optimal position of smooth and rough surface

maximize osseointegration and crestal bone preservation with the SLActiveTM surface to the top

THE STraumann® BonE LEvEL ImpLanT gives you full treatment confidence, designed to preserve crestal bone through the unique Bone Control DesignTM, provides excellent esthetic outcomes through Consistent Emergence ProfilesTM, and simplifies handling with the CrossFitTM Connection.

The Straumann® Bone Level Implant offers you the following benefits:

ß High confidence and treatment predictability thanks to SLActiveTM – the surface with success built in.TM

ß Minimal tissue trauma from start to finish, providing superb esthetic results

ß Same procedures and instruments for all Straumann dental implants

EXCELLEnT ESTHETIC ouTComESTHROUGH CONSISTENT EMERGENCE PROFILESTM

SupErB CrESTaL BonE prESErvaTIonTHROUGH BONE CONTROL DESIGNTM

Microgap control

conical connection designed to provide bacterial seal and minimize sensitivity to lateral forces

Implant surface osseoconductivity

increased treatment predictability and confidence with SLActiveTM surface*

Biomechanical implant design

excellent fatigue strength and optimized force transmission

Straumann developed Bone Control DesignTM based on five fundamental biological principles to maximize crestal bone preservation and soft tissue stability.

* as compared to SLA®

Bone Control DesignTM

Designed to optimize crestal bone preservation by adherence to biological principles

Consistent Emergence ProfilesTM

Experience simplifed soft tissue management from start to finish

CrossFitTM Connection

Feel the fit of the self-guiding connection

"The tissue is the issue but the bone sets the tone."

5

– Dr. D. Garber

Page 2: THE STraumann BonE LEvEL ImpLanT - Toledo Perio

EXCELLEnT ESTHETIC ouTComESTHROUGH CONSISTENT EMERGENCE PROFILESTM

The consistent emergence profiles of Straumann’s prosthetic components are designed to facilitate highly esthetic restorations that mimic natural teeth. These components, designed to match the abutment profiles, allow you to easily attain esthetic results through soft tissue management, allowing for:

ß Minimal tissue trauma from start to finish

ß Simplified soft-tissue management

ß Enhanced patient comfort through

minimized soft tissue impingement

Courtesy of Dr. Barry P. Levin, Elkins Park, PA (surgical), Dr. Brian L. Wilk (restorative)

"The Straumann® Bone Level Implant provides treatment flexibility for patients with thin, scalloped, biotype soft tissue."

TemporaryAbutment

Polymer/Ti

AnatomicAbutment

Ti

Gold Abutment for crown

Au

Gold Abutmentfor bridge

Au

CementableAbutment

Ti

Straumann® CAD/CAM

ZrO2

Straumann® CAD/CAM

Ti

Prosthetic Options for Straumann® Bone Level Implant

† pending FDA clearance

Healing Temporary restoration Final restoration

"The implant procedure is technically no different than what I have been doing except for the new profile drill prep."

LOCATOR® Abutment

Ti

– Dr. Barry P. Levin, Elkins Park, PA

Page 3: THE STraumann BonE LEvEL ImpLanT - Toledo Perio

EXCELLEnT ESTHETIC ouTComESTHROUGH CONSISTENT EMERGENCE PROFILESTM

Feel the fit of the self-guiding connection

The prosthetic connection is intuitive, self-guiding and easy to grasp. The CrossFit™ connection:

ß Gives prosthetic flexibility and stability through its deep conical connection

ß Provides a clear-cut insertion through the guidance of 4 grooves

ß Designed to prevent rotation

conical connection(15˚)

4 grooves

SamE For aLL STraumann® DEnTaL ImpLanTS

SURGICAL KIT,

PROSTHETIC KIT,

PROCEDURE,

and INSTRUMENTS

"The implant procedure is technically no different than what I have been doing except for the new profile drill prep."

SImpLIFIED HanDLInGTHROUGH CrossFitTM CONNECTION

– Dr. William F. Runyan, Fort Worth, TX

Page 4: THE STraumann BonE LEvEL ImpLanT - Toledo Perio

0 1 2 3 4 5 6 7 8

Primarystability

(old bone) Secondarystability

(new bone)

Stabilitydip

Time (weeks)

S. R

agha

vend

ra, M

. Woo

d, T

.D. T

aylo

r (20

05)

Total stability

Stab

ility

SLA®

Stab

ility

0 1 2 3 4 5 6 7 8

Primarystability

(old bone)

Time (weeks)

Total stability

SLActiveTM

Secondarystability

(new bone)

SLA

ctiv

eTM (b

lue

line)

, SLA

® (d

otte

d bl

ue li

ne)

SLA®

Straumann's SLActiveTM surface sets a new standard in implant dentistry. As the first chemically active implant surface, SLActiveTM offers you:

ß Faster osseointegration to enhance confidence*

ß Increased treatment predictability*

ß Reduced healing times, from 6–8 weeks to 3–4 weeks*

ouTSTanDInG SuCCESS raTES SLActiveTM – THE SURFACE WITH SUCCESS BUILT IN.TM

The speed of osseointegration dictates the severity and duration of the stability dip.

SLActiveTM provides more predictability by achieving secondary stability sooner than SLA®.

Secondary Stability Sooner*

+ Clinical studies are ongoing.

* as compared to SLA®

"The results show that the SLActive™ surface is conducive to faster bone healing.*"

Topic Content Study Setup, Principal Investigator

prop

erty

test

s

Biomechanical stability

Ideal strength and fatigue strength of the Straumann® Bone Level Implant in comparison to competitors

Hydropulser tests, ISO 14801,M. Wieland, Switzerland

Reliability Measurement of tight screw fit after cyclic mechanical load of the Straumann® Bone Level Implant

Hydropulser tests, ISO 14801,M. Wieland, Switzerland

Microgap Measurements of gap size and tightness under static and dynamic load

Diverse test setups,M. de Wild, Switzerland

pre-

clin

ical

st

udie

s Bone maintenance

Bone maintenance with submerged and non-submerged implants placed at different heights

Delayed restoration, 60 implants, D. Cochran, USA

Interproximal bone maintenance with adjacently placed implants Immediate restoration, 72 implants, D. Tarnow, USA

clin

ical

stu

dies

Basic clinical evidence+

Performance and esthetic outcome in single tooth gaps in the anterior maxilla

Single center, 20 patients,D. Buser, Switzerland

Esthetics+ Submerged vs. non-submerged placement in the anterior maxilla and mandible

12 international centers, 134 patients, C. Hämmerle, Switzerland

A variety of indications+

Implant success and survival rate in daily dental practice More than 100 centers worldwide, More than 1250 implants

Straumann® Bone Level Implant – Study OverviewTo date, several studies have been initiated to substantiate the performance of the Straumann® Bone Level Implant.

– Dr. David L. Cochran, San Antonio, TX

Page 5: THE STraumann BonE LEvEL ImpLanT - Toledo Perio

Stra

uman

n pr

oduc

ts ar

e C

E m

arke

d

10/

07

USL

IT 2

29

International HeadquartersInstitut Straumann AG Peter Merian-Weg 12CH-4002 Basel, SwitzerlandPhone +41 (0)61 965 11 11Fax +41 (0)61 965 11 01

www.s t raumann.com

North American DistributorsStraumann USA, LLC 60 Minuteman Road Andover, MA 01810 Phone 800/448 8168 978/747 2500 Fax 978/747 2490 www.straumannusa.com

Straumann Canada Limited 4145 North Service Road, Suite 303Burlington, ON L7L 6A3 Phone 800/363 4024 905/319 2900 Fax 905/319 2911 www.straumann.ca

THE STRAUMANN® DENTAL IMPLANT SYSTEM –

Your CHoICE

ConFIDEnCE aT anY LEvEL

Straumann®

StandardStraumann®

Standard PlusStraumann®

Tapered EffectStraumann®

Bone Level

Page 6: THE STraumann BonE LEvEL ImpLanT - Toledo Perio

INTRODUCING ConFIDEnCE AT BonE LEvEL

Featuring

the unique

SLActive™ surface!