2013/SOM3/SCSC/WKSP2/015 Session 6
The Role of Building Energy Modeling in Design Practice in Indonesia
Submitted by: Indonesia
Joint APEC-ASEAN Workshop - How Building Information Modeling Standards
Can Improve Building Performance Medan, Indonesia
24-25 June 2013
06/07/2013
1
BIM WORKSHOP06/07/2013
The Role of Building Energy Modeling in Design Practice in Indonesia
Dr.techn. Rahmi Andarini6 July 2013
1
BIM WORKSHOP06/07/2013
Fact Base•Energy crisis•Government has to subsidize the domestic use of energy•Less subsidies for other sectors
(MEMR 2009)
2
06/07/2013
2
BIM WORKSHOP06/07/2013 3
Jakarta (Megacity)Area : 750 km²Population : 8.5 millions Density : 12,738 /km²
Surabaya (Metropolitan)Area : 290 km²Population : 3.23 millions Density : 10,721 /km²
Fact BaseCities Growing Rapidly
BIM WORKSHOP06/07/2013
The trend of amount of sold electricity by State Electricity Company DKI Jakarta (Source : PT PLN Persero Jakarta, 2012)
4
Fact BaseEnergy Consumption’s Growing
06/07/2013
3
BIM WORKSHOP06/07/2013
����
�����
����
����� �
Indonesian ethnic house
5
BIM WORKSHOP06/07/2013 6
Indonesia’s current situation
06/07/2013
4
BIM WORKSHOP06/07/2013
Weather Data i.e. Jakarta vs Graz
7
Influence of weather
Jakarta, 7.4° South Latitude Graz, 47 ° North Latitude
BIM WORKSHOP06/07/2013 8
DISTRIBUTION OF ENERGY CONSUMPTION TYPE
AC (%)
ELEV/ESC. (%)
LIGHTING (%)
OTHERS (%)
1. Office a. Government 46,80 1,80 21,10 30,30 b. Private 45,74 3,20 21,00 30,05 2. Shopping Center 51,55 4,78 18,57 25,10 3. Office & Shopping Center
47,56 3,82 14,82 33,80
4. Hospital a. Public 60,25 4,43 10,82 24,50 b. Private 62,04 4,27 11,77 21,92 5. Hotel a. Five Stars 60,18 6,44 14,54 18,84 b. Four Stars 60,15 7,68 9,57 22,40 c. Three Stars 65,40 16,10 10,40 8,10 6. Mall 51,90 0,92 11,95 35,20 7. Apartment 53,45 6,75 12,25 27,55 Source : KONEBA, PT. 2006, Survey results in 60 buildings in Jakarta, Indonesia.
Cooling dominates the energy consumption!!!
Energy Consumption for Commercial Building (PT Koneba, 2006)
06/07/2013
5
BIM WORKSHOP06/07/2013 9
• Energy efficient buildings are ofcrucial importance in a context wherecities are booming
• Method on energy efficient building design should be made available
• The existing standards and guidelinesshould be more integrated and comprehensive
• Raising awareness campaign and behaviour changes towards energy effieciency
Therefore...
BIM WORKSHOP06/07/2013 10
The opportunity to change the design is unlimited during the planning stage, and requires no cost
Source : Müller, C., 1999
Impact of Energy Efficient Design
06/07/2013
6
BIM WORKSHOP06/07/2013 11
Building GeometryWeather Data
INPUTS
Construction MaterialInternal Gains
SIMULATION
Schedules People, Equipments, Lightings
InfiltrationHVAC
RESULT
SENSITIVITY ANALYSISRECOMMENDATIONS
FOR ENERGY EFFICIENT BUILDING
Building Thermal Simulation & Analysis
BIM WORKSHOP06/07/2013 12
Case IRenovation Project DGNREEC ‐MEMR
06/07/2013
7
BIM WORKSHOP06/07/2013 13
16 January , 09.00 16 January , 15.00
Case IRenovation Project DGNREEC ‐MEMR
BIM WORKSHOP06/07/2013 14
16 July , 09.00 16 July , 15.00
Case IRenovation Project DGNREEC ‐MEMR
06/07/2013
8
BIM WORKSHOP06/07/2013 15
Case IRenovation Project DGNREEC ‐MEMR
BIM WORKSHOP06/07/2013 16
Case IRenovation Project DGNREEC ‐MEMR
06/07/2013
9
BIM WORKSHOP06/07/2013 17
Case IRenovation Project DGNREEC ‐MEMR
BIM WORKSHOP06/07/2013
No Scenario Recomendation
How Consideration
1. Primary Recommendation 1Improving Lighting Devices o Task Lighting
o Rearrange Lighting Zone o Replacing TLT8 with TLT5 o Housekeeping control on lighting
Potential Saving
Investment Cost
Level of difficulty for Installation
2. Primary Recommendation 2Recommendation 1 and Improving glazing material performance + Chiller Efficiency
o Recommendation 1o Replacing glaze material with SHGC = 0.371; LT =
0.309; U value = 5.797 W/m2 K o Chiller Effiency by:
Conduct online measurement to test overall chillers condition
Check performance of AHUs Replace the old control valve of AHU House Keeping and Maintenance
Potential Saving
Investment Cost
Level of difficulty for Installation
18
Case IRenovation Project DGNREEC ‐MEMR
06/07/2013
10
BIM WORKSHOP06/07/2013
No Scenario Recomendation
How Consideration
3. Secondary RecommendationFloor and Ceiling Material
o Using Carpet Floor and Acoustic Ceiling
Noise Reduction
Investment Cost
Level of difficulty for Installation
4. Additional Recommendation Improving Operational Procedure
o Installing power meter for MVAC, Lighting, and Plug load separately, so that the energy consumption of each load can be monitored.
o Installing BAS in order to monitor & control the energy consumption
o Occupant education to increase the awareness of energy efficiency, such as broadly campaign that the comfort indoor air temperature is 25OC + 1OC, efficient use of lighting device, and so on
Potential Saving
Investment Cost
Level of difficulty for Installation
19
Case IRenovation Project DGNREEC ‐MEMR
BIM WORKSHOP06/07/2013 20
Case IIDesign Project Graha Kirana Megah
06/07/2013
11
BIM WORKSHOP06/07/2013 21
Case IIDesign Project Graha Kirana Megah
Building GeometryZoning
BIM WORKSHOP06/07/2013 22
Case IIDesign Project Graha Kirana Megah
Solar Heat Gain
06/07/2013
12
BIM WORKSHOP06/07/2013 23
Case IIDesign Project Graha Kirana Megah
Solar Heat Gain
BIM WORKSHOP06/07/2013 24
Case IIDesign Project Graha Kirana Megah
Daylighting
Alternative I Alternative II Alternative IV
06/07/2013
13
BIM WORKSHOP06/07/2013 25
Alternative V Alternative VI
Case IIDesign Project Graha Kirana Megah
Daylighting
BIM WORKSHOP06/07/2013 26
Case IIDesign Project Graha Kirana Megah
Cooling