63
The PAX Lite: PAX quality at a great low price.

The PAX Lite: PAX quality at a great low price.. PAX Lite Series Indication and Setpoint Control Simple field set-up Perfect the low-cost meter users

Embed Size (px)

Citation preview

The PAX Lite: PAX quality at a great low price.

PAX Lite Series

Indication and Setpoint Control

Simple field set-up

Perfect the low-cost meter users

Ideal for the OEM market

Designed For Designed For BasicBasic ApplicationsApplications

Bright .56“ Display

AC/DC Powered

PAX Packaging

Variety of Models

With prices starting as low as $105.00

A A PAX LitePAX Lite For Every For Every NeedNeed

Digital Models –

Count, Rate, and Process Time

Analog Models –

Volt, Current, Process, Temperature and Strain Gage

PAX LitePAX Lite Digital Models Digital Models

6 and 8 Digit Counters 6 Digit Rate Indicator 5 (Chronometer) and 6 Digit Process Time Accepts a wide variety of sensors Input Rates up to 25 KHz Programmable Scaling Easy Front Panel Entry with Lockout And now PAXLCR adds Dual Setpoint

capability

PAX LitePAX Lite Analog Models Analog Models

3 ½ Digit Display AC and DC Models Over-range Indication Selectable Decimal Points Optional Custom Units Overlay Simple Scaling Pots No Front Panel Push Buttons And now dual setpoint control is available

in the PAXLA and PAXLT

When your needs are When your needs are basicbasic … …

choose choose PAX PAX LiteLite

PAX: Everything you want in a process meter

Digital Models

Count

Rate

Timer/Real Time Clock

PAXI

PAXR

PAXCK

Analog Models

Temperature

Process

Voltage

Current

Strain Gage

PAXT

PAXH

PAXP

PAXD

PAXS

The PAX Features

Bright .56" LED Display Variable Intensity Display Programmable Keys & User

Inputs NEMA 4X/IP65 UL Listed 508, CE Tested Display Flashing Alarm Condition Plug-in Option Capability

Check out these displays …

Sunlight Readable Red

Display

Standard Green Display

Analog unit only

Custom Units Overlay

Add options now or later

with easy plug-in cards

Optional Plug-in Cards

Setpoint Output– Dual relays– Quad relays– Quad sinking open collector– Quad sourcing open collector

Retransmitted Analog Output– 4 – 20 mA– 0 – 10 VDC

System Capabilities for Plant wide Connectivity

RS485

ModbusRS232

Now programmable in Crimson 2.0 software…

Application

                                  

   

Web Monitoring

Application Details

Want to count material in tenths of feet

Want the ability to change direction

Want to read material speed

Needs two setpoints

Needs 0 to 10 VDC retransmitted

Needs RS485 Comms

Product Selection

Meter – PAXI Counter/Rate Meter

Option Cards

Setpoint – PAXCDS10

Analog – PAXCDL10

Communication – PAXCDC1C

Sensor – LSM Miniature Length Sensor with Poly Wheel

Data Sheet Review

1.0 Installing the Meter

2.0 Jumper and DIP Switch

Adapts to almost any sensor

3.0 Installing Plug-In Cards

4.0 Wiring the Meter

5.0 Front Panel and Display

6.0 Programming Overview

Factory Reset !!!

Code 66

Application Details

Want to count material in tenths of feet

Want the ability to change direction

Want to read material speed

Needs two setpoints

Needs 0 to 10 VDC retransmitted

Needs RS485 Comms

Module 1 - Input Programming

Input Scaling

2000 pulses per foot

Wants to show feet to the tenths

Desired DisplayPulses per Display Unit

= Scale Factor

Input Scaling

2000 pulses per foot

Wants to show feet to the tenths

Desired Display = 1.0 or a Display of 10 with a decimal point (1.0)

Input Scaling

2000 pulses per foot

Wants to show feet to the tenths

10

2000= .005

Scale Factor = .005, Scale Multiplier = 1

Desired Display

Pulses per Display Unit=

Input Scaling w/Multiplier

1500 pulses per foot

Wants to show feet

Better - Scale Factor = .06666, Scale Multiplier = .01

1

1500= 0.0006666

Desired Display

Pulses per Display Unit=

Okay - Scale Factor = .00066, Scale Multiplier = 1

Module 1 - Input Programming

Module 2 - User Programming

External Control

Programming Lockout Change Display Various Resets Inhibit Store Deactivate Setpoints Activate Setpoints Hold Setpoints Change Display Intensity

Module 3 – Display Capability

Display Capabilities

Accessible Displays Lock, Read, and Enter Accessible Setpoints, Scaling, and

Counter Load Value Security Code

Adjustable Cut-to-length

                                 

    

Module 4 – Rate

Calculating for Rate

Rate is represented by a selected display value and the corresponding input pulses that represent that value.

The input value must be calculated in CPS (Cycles per Second) for entry into the PAX meter.

60

0 X

Rate Graph

FPM

CPS

Calculating the CPS

60 FPM x 2000 Pulses

60 Seconds/Minute

Selected Display Value x Representative Pulses

60 Seconds/Minute CPS =

CPS =

CPS = 2000

60

0 2000

Rate Graph

FPM

CPS

60

30

0 1000 2000

Rate Graph

FPM

CPS

Module 4 – Rate

Optimum Speed Equals $$$

                                  

   

Module 5 – Math Function

Display C Funtions

Counter A Add Counter A and Counter B Subtract Counter A and Counter B Slave Display

Tank Level Indication

                               

     

Application Info

Setpoint 1 disengages the motor Setpoint 2 stops the web and cuts the

paper at the desired length Both outputs are maintained until reset

Module 6 – Setpoints

Full Output Control

Action – Latch, Boundary, Time Out Assignment – Counter A , B, C, Rate Logic – Normal, Reverse Hysteresis Setpoint Termination Setpoint Tracking

Module 7 Serial Comms

Available Comms

RS232 RS485 Modbus DeviceNet Profibus Ethernet (Via the ICM8)

Ties to Management System

Module 8 – Analog Output

One Card, Choice of Outputs

Module 9 – Factory Service

The PAX Meters …

much more than just a Panel Meter!

they are part of the system!