2
ISIS IOM Systems for Intraoperative Neuromonitoring • Neurosurgery • Spine surgery • Orthopaedics • Vascular surgery • Cardio and chest surgery • General surgery • ENT surgery The ISIS IOM System Intraoperative neurophysiological monitoring has become the ‘Gold Standard’ to control the nervous system during surgical interventions. The ISIS IOM System is especially designed for that purpose by inomed in cooperation with clinical neuro-physiological specialists. It stands in the forefront of the high-performance devices on the international market. Due to its flexible configuration options, it suits many kinds of operation procedures and can be designed for your individual needs. Take advantage of inomed's well-founded system competence and more than 20 years of experience in the field of neuromonitoring and benefit from comprehensive activity around the intraoperative neuromonitoring. We work continuously on future trends in amplifier technology and soſtware tools as well as offering international application workshops and a fast on-site service. ISIS Neurostimulator The ISIS Neurostimulator is a multifunctional constant current stimulator for the complete range of intraopera- tive neuromonitoring. It provides 12 high current stimulation outputs up to 250 mA and 1 direct nerve stimula- tion output up to 25 mA. The ISIS Neurostimulator can be used with a special soſtware as a stand-alone device or can be used as a part of the ISIS IOM system, which is controled by the soſtware NeuroExplorer. Parameters for various stimulation modes can be modified and saved permanently. Integrated in the ISIS IOM system the ISIS Neurostimulator allows to use every channel for different neurophysiological measurement methods. This option as well as the possible stimulation current up to 250 mA and the continous control of stimulation electrode impedances during the surgery gives the high flexibility needed for the latest standard of intraoperative neuromonitoring. Adaptor Special adaptors for stimulation and recording have colour coded plug-ins, connec- tors and cable. Combined with a significant inscription this leads to an easy handling. Electrodes and probes can hence be connected to the system without problems. ISIS Headbox Each ISIS Headbox consists of 8 input channels and acts combined with a medical computer as a complete unit for the recor- ding of electrophysiological signals. Additionally an output for AEP stimulation can be integrated. The recorded signals are digitised directly in the Headbox and are transmitted to the PC via USB-interface. This enables optimal signal acquisition without significant artefacts despite difficult conditions in the operating room. ISIS System Components

The ISIS IOM System ISIS System Components€¦ · The ISIS Neurostimulatorcan be used with a special softwareas a stand-alonedevice or can be used as a part of the ISIS IOM system

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: The ISIS IOM System ISIS System Components€¦ · The ISIS Neurostimulatorcan be used with a special softwareas a stand-alonedevice or can be used as a part of the ISIS IOM system

ISIS IOM Systemsfor IntraoperativeNeuromonitoring

•Neurosurgery•Spinesurgery•Orthopaedics•Vascularsurgery•Cardioandchestsurgery•Generalsurgery•ENTsurgery

The ISIS IOM System

Intraoperativeneurophysiologicalmonitoringhasbecomethe‘GoldStandard’tocontrolthenervoussystemduringsurgicalinterventions.TheISISIOMSystemisespeciallydesignedforthatpurposebyinomedincooperationwithclinicalneuro-physiologicalspecialists.Itstandsintheforefrontofthehigh-performancedevicesontheinternationalmarket.Due to its flexibleconfigurationoptions, it suitsmanykindsofoperationproceduresandcanbedesignedforyourindividualneeds.Takeadvantageofinomed'swell-foundedsystemcompetenceandmorethan20yearsofexperienceinthefieldofneuromonitoringandbenefitfromcomprehensiveactivityaroundtheintraoperativeneuromonitoring.Weworkcontinuouslyonfuturetrendsinamplifiertechnologyandsoftwaretoolsaswellasofferinginternationalapplicationworkshopsandafaston-siteservice.

ISISNeurostimulatorTheISISNeurostimulatorisamultifunctionalconstantcurrentstimulatorforthecompleterangeofintraopera-tiveneuromonitoring.Itprovides12highcurrentstimulationoutputsupto250mAand1directnervestimula-tionoutputupto25mA.TheISISNeurostimulatorcanbeusedwithaspecialsoftwareasastand-alonedeviceorcanbeusedasapartoftheISISIOMsystem,whichiscontroledbythesoftwareNeuroExplorer.Parametersforvariousstimulationmodescanbemodifiedandsavedpermanently.IntegratedintheISISIOMsystem the ISISNeurostimulator allows to use every channel for different neurophysiologicalmeasurementmethods.Thisoptionaswellas thepossiblestimulationcurrentupto250mAandthecontinouscontrolofstimulationelectrodeimpedancesduringthesurgerygivesthehighflexibilityneededforthelateststandardofintraoperativeneuromonitoring.

AdaptorSpecial adaptors for stimulation and recording have colour coded plug-ins, connec-torsandcable.Combinedwithasignificant inscription this leads toaneasyhandling.Electrodesandprobescanhencebeconnectedtothesystemwithoutproblems.

ISISHeadboxEachISISHeadboxconsistsof8inputchannelsandactscombinedwithamedicalcomputerasacompleteunitfortherecor-dingofelectrophysiologicalsignals.AdditionallyanoutputforAEPstimulationcanbeintegrated.Therecordedsignalsaredigitiseddirectly in theHeadboxandare transmitted to thePCviaUSB-interface. Thisenablesoptimal signalacquisitionwithoutsignificantartefactsdespitedifficultconditionsintheoperatingroom.

ISIS System Components

Page 2: The ISIS IOM System ISIS System Components€¦ · The ISIS Neurostimulatorcan be used with a special softwareas a stand-alonedevice or can be used as a part of the ISIS IOM system

Seite 4 Wickelfalz um 2 mm verkürzt schneiden! Rückseite von Seite 5

ISISMERSystemWhenimplantingaDBSelectrode,theintraoperativemicro-electroderecording(MER)techniqueisusedtoensurethattheexpectedtargetpointdeterminedinpathplanningisreached.Thisinvolvesintroducingmicro-macroelectrodesalongaplan-nedtrajectoryandrecordingthedifferingneuronalactivity.

TheISISHeadboxMERoffersthecompletehardwarebasisfortargetpointlocalisationindeepbrainstimulation.Itincludes5MERamplifierchannelsforextracellularrecordingandanintegratedstimulatorfordeepbrainstimulation.Theproductrangealsoincludestheautoclavablerecordingcablesandtheelectrodesnecessaryforrecordingandteststimulation.RecordingcablesareprovidedforusewithboththeinomedMicroMacroandtheinomedMicroMoveelectrodes.

ISISMicroDrive

ISISMERSoftware

ISISMERRecordingCable

ISISHeadboxMER

TheelectrodesareintroducedbytheMicroDrivesystemwhichadvancesuptofiveelectrodessimul-taneouslyintothetissue.Hapticfeedbackafteradefinedrotationconstantlyprovidesthesurgeonwith certainty regarding the insertion depth already achieved. The depth sensor also allows thestereotacticpositionoftheelectrodestobetransmittedfullyautomaticallytotheISISMERSystem.

D03010

1ENrev1.2.Contentsub

jecttoalteratio

ns©co

pyrightbyinomed03.20

13

inomedMedizintechnikGmbHImHausgruen2979312Emmendingen(GERMANY)Tel.:+4976419414-0Fax:[email protected]

Certified in accordance withDINENISO13485:2003 0297

ISIS IOM Software NeuroExplorer

ThesoftwareNeuroExplorerenablestocreateandmemorizeanunlimitednumberofprogramswithindividualmeasurementmodalities.Yoursystemcanbeactivatedwiththeintendedfunctionsbysimplypressingonebutton.

Theflexibilityineachprogramallowsanintraoperativeadjustementofthedisplayandparameterslikecascades,trendcurves,ampli-tudeandtimebaseetc.duringmeasurement.Theintervaltimeforthedifferentmeasurementscanbesetindividually,thusprioritiescanbemadewithoutskippingothermeasurements.ThevideooptionallowstosynchronizevideoandEMG/EPrecordingsinreal-timeforlateranalysisorjustfordocumentation.Remotemonitoringisanadditionalfeaturewhichallowstoseethescreenfromeveryplaceevenoutsidetheoperationroom.

Narcotrend®Integrationformeasuringtheanaesthesiadepth

Pentero®Interfacetosuperimposerelevantmeasuringdataintothemicroscopeeyepiece

Screen2Videorecordingwithaudiosynchronization

Features

RemoteMonitoring

Networkoption

iSSS-inomedSystemSecuritySolution

UpgradepossibilitywithMER

Videomodulewithsynchronizationfunction

iPadApp

iSSS-inomedSystemSecuritySolutionBynetworkingdifferentsystemsinthehospitalandexchangingvariousdatawithdifferentmedia,thedangerofviralinfectionsandmalwaregrowssignificantly.Inappropriatehandlingleadedtoexpensivesystemfailuresinthepast.TopreventthosekindoffailurestheiSSS–inomedSystemSecuritySolution–wasdevelopedfortheISISsystems.

Forsafeuseofourinomedsystemsinclinicalperformanceandnetworkconnectivity,allISISsystemswillbeprovidedautomaticallywithiSSSandupdatedperiodicallywithapprovedandadaptedvirusdefinitions.

1Onlyoneofthenumberedoptionscanbechoosen.

ISIS System Versions

Configuration ISISIOMSystem ISISIOMSystemCompact

ISISIOMSystemPortable

BaseunitwithPC,inomedmonitorheightadjustablewithhotkeyfunction,laserprinter,keyboardandtwoaccessoriesdrawers

BaseunitwithPC,monitor,keyboarddrawerandaccessoriesbasket

Optioninomedmonitor

Multitouchoptionforinomedmonitor

Caseunitwithlaptop,wheelsandremovabletelescopichandle

Amplifierchannels max.128,individualconfigurable

max.24,individualconfigurable

max.24,individualconfigurable

Software Module

EMGsoftwaremodule

SEPsoftwaremoduleincludingPRSEP

AEPsoftwaremodule

MEPsoftwaremodule

VEPsoftwaremodule

EEGsoftwaremodule

Features

Softwaremutefunctiontoreducedisturbingnoisefromcautering

Externalmutesensortoreducedisturbingnoisefromcautering

Videomodulewithsynchronizationfunction RemoteMonitoring

Narcotrend®Integration

ZeissPentero®Integration Screen2Videorecordingwithaudiosynchronization

NetworkOption

UpgradepossibilitywithMER(5channels)

iSSS-inomedSystemSecuritySolution

11

11