Backed by our nationwide network of experienced applicators and a strict quality assurance program, Level-Right® is the right solution to any floor leveling problem. Best of all, Level-Right helps you save time and money while creating a floor that more than stands up to specification.
The fasT, CosT-effeCTive fLooR LeveLing sysTem
LeveL-RighT fLooR sysTems
LeveL-RighT®
Level-Right® self-Leveling floor Underlayment is a specially formulated, high-strength cementitious underlayment that can handle any floor leveling challenge — often without shotblasting or scarifying.
Level-Right is poured over precast or cast-in-place concrete, terrazzo, ceramic, quarry, marble tile, old vinyl tile, and tile adhesives — providing a level, smooth surface. hand troweling and hand finishing are unnecessary. Level-Right accepts practically any floor covering.
With Level-Right there is no extensive curing time. Ceramic tile can be thin set within 2 to 4 hours. other floor goods can be installed once Level-Right passes a moisture test.
feaTURes/BenefiTs•�� Pre-blended mix of high strength cements and special additives•�� Water resistant• Pours over concrete and old floor goods and adhesives• ideal for large projects or small repair jobs• no special prepping, removal of old floor goods, or hand finishing
required• sets fast, can be walked on within two to four hours• Compressive strengths up to 5,500 psi (37,895 kPa)• Can be featheredged• Tested at the manufacturing plant and the job site to meet our
stringent quality assurance requirements• Contains recycled materials• gReengUaRD and gReengUaRD gold Certified
The RoCk soLiD soLUTion To Uneven fLooRs
Camden middle SChool CamDen, ny
architect: king+king architects general Contractor: murnane Building Contractors scope: 1,500 sq. ft. of Level-Right poured at 0 to 11⁄2” depth
TeChniCaL DaTa
LEED Certification ........... may help contribute toward earning points, see www.maxxonCorporation.com
Flexural Strength ..............................1,260 Psi (8.7 mPa) 28 daysasTm C 348
Dry Density ................................ approx. 125 lbs/ft3 (2,003 kg/m3)
VOC Emissions ..................................gReengUaRD gold Certified
ICC-ES ................................................... evaluation Report esR-2540
Tensile Strength .......................................720 Psi (5 mPa) 28 daysasTm C 190
Compressive Strength ...........Typical: 3,000 Psi (20.6 mPa) 3 daysmodified asTm C 109 4,500 Psi (31 mPa) 7 days 5,500 Psi (38 mPa) 28 days
Fuel Contribution .................................................................... 0Smoke Density ........................................................................ 0Flame Spread ......................................................................... 0
Fire Performance asTm e-84
The RoCk soLiD soLUTion To Uneven fLooRs
LimiTaTions 1. Do not pour Level‑Right® where the floor temperature
is less than 50 °F (10 °C) or greater than 100 °F (37.7 °C).
2. Protect the poured mortar from wind and sun, and from freezing temperatures for the first 72 hours.
3. Level‑Right cannot resist stresses caused by structural movement.
4. The structural subfloor and floor joist must comply with manufacturers’ maximum span criteria. Typically a deflection limitation of L/360 is adequate for Maxxon Underlayments. Some floor coverings such as marble, stone, travertine, and ceramic tile may require a stiffer floor system. Maxxon Underlayments are non‑structural and therefore cannot be expected to reinforce structurally deficient subfloors. The general contractor, architect, specifier, or building owner should make necessary allowances for expected live, concentrated, impact, and/or dead loads including the weight of finished floor goods and setting beds.
5. During construction, place temporary wood planking over the underlayment wherever it will be subjected to heavy wheeled or concentrated loads.
6. Level ‑Right is for interior use only; it is not a wearing
surface.
7. Level‑Right will not structurally bridge over expansion joints, saw cuts or structural cracks. They should be allowed to continue through the Level ‑Right. The architect or structural engineer must specify expansion joints and show their location in areas that will receive hard surface floor goods, such as ceramic or marble tile and hardwood flooring.
8. For deeper fills, call Maxxon Corporation for application procedures.
9. For applications other than those over structural concrete call Maxxon Corporation for application procedures.
10. Maxxon Underlayments are “breathable” and not a vapor barrier. The general contractor, architect, specifier, or building owner shall test slabs‑on‑ground or elevated slabs for MVER (ASTM F1869) or RH (ASTM F2170). If the MVER or RH of the concrete substrate exceeds the floor covering manufacturer’s respective requirements for the finished flooring system, the concrete must be treated with a moisture barrier, such as Maxxon DPM or Maxxon MVP, before installation of a Maxxon Underlayment.
PRoDUCT sUPPoRT Additional product literature, CSI formatted specifications and information are available upon request. For special applications, contact Maxxon Corporation.
TesTing Field testing must be performed in accordance with modified ASTM C109 using 2” by 2” (50mm x 50mm) cube molds. Before independent sampling, contact the Maxxon Quality Assurance Department to ensure that proper procedures are followed.
WaRRanTy Maxxon Corporation warrants Level‑Right to be free from manufacturing defects as defined in this warranty. Manufacturing defects are considered to be those defects that occur due to the quality of the Level‑Right ingredients or from the manufacturing process itself. This warranty does not include labor costs and other costs or expenses associated with the removal or installation of Level‑Right. Because Maxxon Corporation does not perform the actual Level‑Right installation, it cannot be held responsible for the results of the application. Maxxon Corporation specifically disclaims problems that occur due to weather conditions, structural movement, structural design flaws and application techniques. This warranty is in lieu of all other warranties expressed or implied including the warranty of merchantability and fitness of a particular purpose and of all other obligations and liabilities on Maxxon Corporation’s part. Maxxon Corporation neither assumes nor authorizes any person to assume for Maxxon Corporation any liability in connection with the sale and installation of Level‑Right Self‑Leveling Floor Underlayment.
PRePaRaTion Concrete subfloors must be fully cured, moisture free and have no efflorescence. The substrate surface shall be clean, dust and contaminant free. Cracks should be filled with a crack filler or an elastomeric compound. Plumbing or electrical penetrations should be packed with insulation and sealed. No air movement, windows must be closed and no direct sunlight during the pour.
DRying ConDiTionsThe general contractor must provide and maintain correct environmental conditions to keep the building clean and dry, and protect against infestation of moisture from a variety of potential sources. Moisture can be introduced by other trades through spillage, tracked in mud and rain, plumbing leaks, etc. Often stored in damp conditions, building products may arrive on site laden with moisture that releases after installation. Outside sources such as rain, snow, wind, etc. can also increase moisture levels.Controlling moisture levels in the building, through appropriate trade sequencing and prevention of potential damage by other trades, is the responsibility of the general contractor. The general contractor must supply mechanical ventilation and heat if necessary. These controls fall under the scope of work of the general contractor — not Maxxon Corporation or the Maxxon Underlayment installer.See Maxxon Building Conditions Guide for additional information.
fiRe RaTingsUL Design
ULC Design
G230G516G524G551G553G560G561G563G566G569G571G574G576J917J919J920J924J927J931J957
J991J994L006L201L202L206L208L209L210L211L212L501L502L503L504L505L506L507L508L509
L510L511L512L513L514L515L516L517L518L519L520L522L523L524L525L526L527L528L529L530
L532L533L534L535L536L537L538L539L540L541L542L543L545L546L547L549L551L552L556L557
L558L560L562L563L564L565L569L570L573L574L576L577L579L581L583L588L589L590L592L593
M500M502M503M504M505M507M508M510M511 M513M514M515
I530L003
L201L511
L512M500
M501M503
M514M520
M521
LEED® INFORMATIONfor information regarding how Level-Right
may contribute toward points for LeeD project contribution, contact your Regional
Representative at (800) 356-7887 or visit www.maxxon.com/go_green.
fiRe/soUnD RaTingsInternational Code Council
Accepted by local building officials for fire and sound code compliance, ICC ES Evaluation Reports are technical reports that verify that specific products meet the following code requirements and warrant regulatory approval. Minimum code requirements: Sound - 50 STC/IIC, Fire - I Hour
ICC ESR #2540 - For the following assembly type:
Additional ICC ES Reports:ESR #1141
ESR #1153ESR #1774
• Parallel Chord Truss• 2x10 Wood Truss • I-Joist
• Trus Joist• Precast Concrete
© 1996‑2013 Maxxon Corporation. All Rights Reserved. Level‑Right is a registered trademark of Maxxon Corporation, Hamel, MN, USA. Printed in the USA. #62030, TA504‑5977, 2/14.
For more info: 800-356-7887 • email: [email protected] www.maxxonCorporation.com
Another superior product from: Maxxon® Corporation • 920 Hamel Road • P.O. Box 253 Hamel, MN 55340 USA • 763‑478‑9600 • Fax: 763‑478‑2431
gReen LeveL-RighT sUCCess sToRies
•�New�construction�or�renovation•��Levels�entire�floors�or�transition�areas,
featheredge to deepfill•�Tops�old�ceramic,�marble�or�terrazzo�floors•�Encloses�VCT,�VAT�or�asbestos�adhesive•�Caps�cracked,�lightweight�concrete•�A�“green”�building�material
Gypsum Wallboard
Steel or Wood Stud and Plate
Level-Right®
Level-Right®
Sealed Joint
Precast or Poured Concrete
Gypsum Wallboard
Steel or Wood Stud and Plate
Carpet, Tile or Other Floor Goods
Existing Uneven Concrete
Gypsum Wallboard
Steel or Wood Stud and Plate
Level-Right®
Level-Right®
Sealed Joint
Precast or Poured Concrete
Gypsum Wallboard
Steel or Wood Stud and Plate
Carpet, Tile or Other Floor Goods
Existing Uneven Concrete
LEED SILVER CERTIFIED REnoVATIon
LEED GoLD CERTIFIED REnoVATIon
Child, adoleSCent & Women’S mental health Building BRITISH CoLUMBIA, VAnCoUVER
national Center for toxiCologiCal reSearCh (nCtr) JEFFERSon, AR
Green Data: In this LEED Silver certified project, Level‑Right was selected for its low VoC emissions and recycled material content
Scope: 60,000 sq. ft. of “Green” Level‑Right poured at 1/2” over old rough concrete
Contractor: Smith Bros. & Wilson (B.C.) Ltd.
Architect: Henriquez Partners & IBI Group Architects in joint venture
Green Data: This was a LEED Gold certified renovation, turning former laboratory/production space into office space
Scope: 44,000 sq. ft. of “Green” Level‑Right
Contractor: CWR Inc.
Architect: Kling Stubbins
geT a fasT fLooR faCeLifT WiTh LeveL-RighT
MADE IN THE USA
Underwriters Laboratories Inc.® Listed