Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
The electron and positron spectra measured by AMS-02
Claudio Corti on behalf of the AMS-02 collaboration
CosPA 2013 – November 14, 2013
11/14/2013
BackgroundsBackgrounds
/ 3211/14/2013 2 The electron and positron spectra measured by AMS-02 - Corti
Casolino et al - 10.1016/j.nuclphysbps.2011.03.049
≈ 50 ÷ 500
≈ 103 ÷ 104 ≈ 10 ÷ 20
11/14/2013
The AMS-02 experimentThe AMS-02 experimentTRD
Silicon Tracker
ECAL
TOF
Magnet
RICH
Identify e+, e-
Z, P
E, Identify e+, e-
Z, β
Z, β
±Z
Z, P, E, β are measured independently by the tracker, RICH, TOF and ECAL
/ 3211/14/2013 3 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
The positron fraction measurementThe positron fraction measurement
f =e +
e ++e−
/ 3211/14/2013 4 The electron and positron spectra measured by AMS-02 - Corti
Proton rejection– cut on ECAL estimator– fit on TRD estimator
Electron/positron distinction– Sign of rigidity (P)
Charge confusion estimation– fit on E/P
11/14/2013
ECAL estimator: BDTECAL estimator: BDT
/ 3211/14/2013 5The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
TRD estimator: Log LikelihoodTRD estimator: Log Likelihood
/ 3211/14/2013 6 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
Charge confusionCharge confusion
The difference between the charge confusion from data and MC is taken as the associated systematic error.
MCISS data
Two sources: Large angle
scattering (spillover) Production of
secondary tracks along the path of the primary track (wrong hits association)
/ 3211/14/2013 7 The electron and positron spectra measured by AMS-02 - Corti
CC = N wrong sign/ (N wrong sign+N right sign)
11/14/2013
TRD-LL vs E/P templateTRD-LL vs E/P template
88 / 3211/14/2013 8 The electron and positron spectra measured by AMS-02 - Corti
From data
From MC
11/14/2013
2D template fit2D template fit
/ 3211/14/2013 9 The electron and positron spectra measured by AMS-02 - Corti
2-D fit to TRD estimator and E/P is performed separately on positive and negative rigidity to determine positron or electron signal, proton background and charge confusion simultaneously.
11/14/2013
The positron fractionThe positron fraction
1010 / 3211/14/2013 10 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
The e+ and e- flux measurementThe e+ and e- flux measurement
Φ(E , E+Δ E) =N obs (E , E+Δ E )
Δ E ΔT exp Aeff ϵtrig
ΦN obs
ΔT exp
Aeffϵtrig
= Absolute differential flux (m-2 sr -1 s-1 GeV-1)= Number of observed events= Exposure time (s)= Effective acceptance (m2 sr)= Trigger efficiency
/ 3211/14/2013 11 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
: TRD-LL template fit: TRD-LL template fitN obs
Measurement is performed for the BDT cut that minimizes the overall statistical and systematic uncertainty
/ 3211/14/2013 12 The electron and positron spectra measured by AMS-02 - Corti
Separate fit for positive and negative rigidity
Number of fitted “e+” and “e-” corrected for change confusion estimated from MC
11/14/2013
: Exposure time: Exposure time Data taking period: May 19, 2011 – May 19, 2013 Total exposure time constant above 25 GeV ≈ 5x107 s Average livetime for primary CRs ≈ 82% (including SAA,
detector dead time, Soyuz docking/undocking, etc)
ΔT exp
/ 3211/14/2013 13 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
: Acceptance: Acceptance
Aeff (E) = Agenerated×N selected (E)
N generated (E)
The effect of every cut has been checked on ISS data and, if needed, the value of the acceptance has been “corrected” (O(%))
Estimated with MC Geant4
Aeff
/ 3211/14/2013 14 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
: Trigger efficiency: Trigger efficiency
15
Estimated directly from data: AMS-02 record unbiased trigger events with a pre-scaling factor
ϵtrig
ϵtrig =N phys
N phys+ f ps N unbias
f ps
100% efficiency above E = 3 GeV15 / 3211/14/2013 15 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
Systematic errors: acceptanceSystematic errors: acceptance
16
Tracker reconstruction =# e± with a track
# e± through Trk acceptance
The uncertainty on the MC/Data agreement has been quoted as systematic
16 / 3211/14/2013 16 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
Systematic errors: BDT cut stabilitySystematic errors: BDT cut stability
In each energy interval the cut on the ECAL BDT has been varied around the working point to verify the stability of the measurement.The RMS of the estimated number of e±, over a wide range of BDT cut efficiencies has been quoted as systematic
/ 3211/14/2013 17 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
Systematic errorsSystematic errors Selection MC/Data comparison 2-3%≈ Normalization Track/No-Track analysis 3%≈ Energy smearing (< 2 GeV) 1%≈ Stability vs BDT cut efficiency 1%≈ TRD-LL reference template for protons 1%≈
/ 3211/14/2013 18 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
The electron spectraThe electron spectra
1919 / 3211/14/2013 19 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
The positron spectraThe positron spectra
2020 / 3211/14/2013 20 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
The electron and positron combined spectraThe electron and positron combined spectra
/ 3211/14/2013 21 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
The electron and positron combined spectraThe electron and positron combined spectra
/ 3211/14/2013 22 The electron and positron spectra measured by AMS-02 - Corti
(2010)
11/14/2013
Fermi flux from positron fraction paperFermi flux from positron fraction paper
/ 3211/14/2013 23 The electron and positron spectra measured by AMS-02 - Corti
Ackermann et al - 10.1103/PhysRevLett.108.011103
11/14/2013
AMS – Fermi “comparison”AMS – Fermi “comparison”
/ 3211/14/2013 24 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
ConclusionsConclusions
2525 / 3211/14/2013 25 The electron and positron spectra measured by AMS-02 - Corti
6.5x106 electrons out of 25x10≈ 9 triggers have been used to publish the measurement of the positron fraction up to 350 GeV
9x106 electrons out of 30x10≈ 9 triggers have been used to measure the separated and combined electron and positron spectra up to 700 GeV
This corresponds to 10% of the ≈expected data sample
The analysis is being finalized for the publication
11/14/2013
Backup slidesBackup slides
2626 / 3211/14/2013 26 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
OutlineOutline AMS-02 experiment Analysis Systematic errors Results
2727 / 3211/14/2013 27 The electron and positron spectra measured by AMS-02 - Corti
: Event selection: Event selection DAQ: efficient data periods (no SAA) Geomagnetic effects: E > 1.25 max cutoff TRD: minimum 8 hits used for e/p identification (TRD-LL) TOF: relativistic down-going particle ECAL: shower axis within fiducial volume and
electromagnetic shape of the shower (BDT estimator) Tracker: Z < 1.5 and track/ECAL matching
N obs
/ 3211/14/2013 28 The electron and positron spectra measured by AMS-02 - Corti
11/14/2013
Charge confusion subtractionCharge confusion subtraction
2929 / 3211/14/2013 29 The electron and positron spectra measured by AMS-02 - Corti
CC = NW/(NW + NR) N+ = Npos (1 – CC) + Nele CC : observed positrons N- = Npos CC + Nele (1 – CC) : observed electrons
11/14/2013
BDT cut efficiencyBDT cut efficiency
/ 3211/14/2013 30 The electron and positron spectra measured by AMS-02 - Corti
An enriched sample in electrons is selected by means of negative sign of the charge and E/P matching. The same fitting procedure as on the full sample is applied in order to estimate the number of electrons as a function of the BDT cut.
11/14/2013
TRD-LL template definitionTRD-LL template definition
/ 3211/14/2013 31 The electron and positron spectra measured by AMS-02 - Corti
Use 21 different selections varying (E/|P|, BDT) to define the proton template and see the effect on the measurement.
11/14/2013
Bin-to-bin migration (energy smearing)Bin-to-bin migration (energy smearing)
/ 3211/14/2013 32 The electron and positron spectra measured by AMS-02 - Corti
ECAL resolution = 1.7 % @100 GeVSmearing effects not negligible only below few GeV