WWW.TEST-FUCHS.COMTEST-FUCHS GmbH / Test-Fuchs Strasse 1-5 / A-3812 Gross-SieghartsT +43(0)2847 9001-0 / F +43(0)2847 9001-299 / [email protected] v 1.0U

Test Stand for Safety Valve>PSV1000n<

For testing of safety valves of the aircraft typesA319, A320, A321, A330 and A340 for functionand leakage

> Each part of the test chamber is protected by asafety valve.

> Simulation of cabin pressure by filteredcompressed-air.

> Closing of the test chamber by a hydraulic clapingsystem; clamping pressure monitoring by means ofpressure switches.

Page1 / 2

PNEUMATICS

Page 2: Test Stand for Safety Valve - Welcome to TEST-FUCHS · Title: Test Stand for Safety Valve Author: TEST-FUCHS Subject: Test Stand for Safety Valve Created Date: 5/29/2012 12:23:14

WWW.TEST-FUCHS.COMTEST-FUCHS GmbH / Test-Fuchs Strasse 1-5 / A-3812 Gross-SieghartsT +43(0)2847 9001-0 / F +43(0)2847 9001-299 / [email protected]

>PSV1000N<

BEKO

TECHNICAL DATA

> The test stand is in compliance with the ergonomic requirements. The suspended operating unit can bemoved and rotated horizontally.

> Supply voltage, test stand:

Mains supply: 3/PE AC 50Hz 400V

Power: max. 18.7kVA

Preliminary fuse: 32A

> Supply voltage, computer:

Mains supply: 1/N/PE AC 50Hz 230V

Power: max. 0.8kVA

Preliminary fuse: 16A

> Supply voltage, lighting:

Mains supply: 1/N/PE AC 50Hz 230V

Power: max. 3.0kVA

Preliminary fuse: 16A

> Pneumatic supply:

Range: 6 to 10bar

Air volume: 2.5kpm

> Measurements:

Flow 0.1 to 2.5kpm Cl. 1.0

0.1 to 150gpm Cl. 1.0

Differential pressure to ± 1000mbar Cl. 0.15

Absolute pressure 0 to 6bar Cl. 0.25

Temperature, test chamber 0 to 50°C ± 1K

Absolute pressure, ambient 0.9 to 1bar Cl. 0.25

Humidity and temperature measurement, ambient

0 to 100%rF Cl. 3.0

-20 to +60°C Cl. 0.5

> Dimensions and weight:

LxDxH: 3900mm x 1140mm x 1980mm

Weight: 2120 kg

Technical data are subject to change!!

Page 2 / 2

GENERAL INFORMATION