    Vessel

    Name :OB FAMIDA

    Period : April 2015 TGL BLN THN S : Scheduled Maintenance for Next Month

    Date Last

    OverhoulJanuary-14 6 4 2015 C : Completed Maintenance for This Month

    O : Overdue Maintenance for This Month

    Months Hours Jan-15 Feb-15 Mar-15 Apr-15 May-15 Jun-15 Jul-15 Aug-15 Sep-15 Oct-15 Nov-15 Dec-15

    5.1 TEMPERATURE INDICATOR INDIKATOR TEMPERATUR

    5.1.1

    Remove temperature indicator from the place, cleaning sensor

    from sludge and be sure temperature indicator normaly

    function

    Lepas indikator temperatur dari tempatnya dan bersihkan

    sensor dari jelaga pastikan indikator temperatur berfungsi

    dengan baik

    30/Mar/15 1 3 30-Jun-15 C S

    5.1.2Visual check condition of sensor and temperature casing not

    broken

    check kondisi visual sensor dan casing temperatur tidak ada

    yg pecah atau rusak30/Mar/15 1 1 30-Apr-15 C S

    5.1.3Visual check condition, when temperature indicator working

    no oil leaking, repair if necessary

    check kondisi visual ketika temperatur dipasang tidak ada

    kebocoran atau rembesan oli, perbaiki jika diperlukan30/Mar/15 1 1 30-Apr-15 C S

    5.1.4Compared with other thermometers when thermometer

    working.

    Bandingkan dengan thermometer lain ketika thermometer

    bekerja30/Mar/15 1 1 30-Apr-15 C S

    5.2 PRESSURE SWITCHES PRESSURE SWITCHES

    5.2.1

    Connect the test equipment to the test cock. Raise the test

    pressure to the value above the switch setting and then slowly

    reduce the pressure until the pressure switch contacts work.

    Hubungkan peralatan pengujian untuk cock uji . Tingkatkan

    tekanan tes dengan nilai di atas pengaturan switch dan

    kemudian perlahan-lahan kurangi tekanan sampai kontak

    saklar tekanan bekerja.

    30/Mar/15 1 3 30-Jun-15 C S

    5.2.2

    Observe the alarm lamp on the engine alarm panel. Check the

    pressure gauge on the test equipment (pressure test pump)

    during the test.

    Amati lampu alarm pada panel alarm mesin . Periksa

    pengukur tekanan pada alat uji ( tes tekanan pompa ) selama

    pengujian

    30/Mar/15 1 3 30-Jun-15 C S

    5.2.3If the set-point is not in accordance with the previous setting

    readjust if necessary.

    Jika set -point tidak sesuai dengan pengaturan sebelumnya -

    sesuaikan kembali jika perlu. 30/Mar/15 1 3 30-Jun-15 C S

    5.2.4 Check cable connections and cable entries to the sensor. Periksa kabel koneksi dan kabel yang masuk ke sensor 30/Mar/15 1 1 30-Apr-15 C S

    5.2.5

    Check that there is no leakage of oil or water inside the

    sensor. If any, clean the sensor and make repairs to eliminate

    further leakage.

    Periksa bahwa tidak ada kebocoran oli atau air dari sensor

    atau koneksi sensor. Jika ada , bersihkan sensor dan perbaiki

    untuk menghindari kebocoran lebih lanjut.

    30/Mar/15 1 1 30-Apr-15 C S

    5.3 GENERAL GENERAL

    5.3.1 Check general condition of Insulation of exhaust pipes Check general condition of Isolasi pipa gas buang 30/Mar/15 1 1 30-Apr-15 C S

    5.3.2 Test Emergency stop of Cargo engine from main deck Test Emergency stop untuk mesin cargo di main deck 30/Mar/15 1 1 30-Apr-15 C S

    5.3.3 Test Fire pump Test fire pump 30/Mar/15 1 1 30-Apr-15 C S

    5.3.4 Test quick closing valve Test quick closing valve 30/Mar/15 1 1 30-Apr-15 C S

    5.3.5 Test emergency stop blower PR Test emergency stop blower PR 30/Mar/15 1 1 30-Apr-15 C S

    5.3.6 Test emergency lighting Test emergency lighting 30/Mar/15 1 1 30-Apr-15 C S

    5.3.7 Check general condition of Control consoles Check general condition of konsol control 30/Mar/15 1 1 30-Apr-15 C S

    5.4 BILGE & BALLAST SYSTEM BILGE & BALLAST SYSTEM

    5.4.1 T es t E .R . b il ge F WD hi gh le ve l a la rm Te st E .R . b il ge FW D h ig h l ev el al ar m 30/Mar/15 1 1 30-Apr-15 C S

    5.4.2 Test E.R. bilge aft high level alarm Test E.R. bilge aft high level alarm 30/Mar/15 1 1 30-Apr-15 C S

    5.4.3 T es t S te er in g b il ge h ig h l ev el a la rm Te st S te er in g b il ge h ig h l ev el a la rm 30/Mar/15 1 1 30-Apr-15 C S

    5.4.4 Tes t S lu dge ta nk hi gh l eve l a la rm Te st S lu dg e t an k h igh le ve l a la rm 30/Mar/15 1 1 30-Apr-15 C S

    5.5 ADDITIONAL ALARMS ADDITIONAL ALARMS

    5.5.1 Test Fire alarm Test Fire alarm 30/Mar/15 1 1 30-Apr-15 C S

    5.5.2 Test Gas detector P.R Test Gas detector P.R 30/Mar/15 1 1 30-Apr-15 C S

    5.5.3 Test Fire detector alarm Test Fire detector alarm 30/Mar/15 1 1 30-Apr-15 C S

    Summary of Overdue Maintenance

    PMS

    No.

    TEST PROGRAM

    Form LF- E 035

    Revision

    Page 1 Of 2

    PERIOD OF PMS REPORT PERIOD OF PMS REPORT April 2015

    PMS No. Unit / System Unit / System P I C Last Maint. DateRunning

    Hours

    IntervalEst. Next Due

    2015

    Symbol

    COMPLETE MAINTENANCE ITEM FOR23 PERFORMANCE 100%April-15

    MAINTENANCE OVERDUE ITEM FOR0

    PMS TEST PROGRAM FOR

    THIS MONTHEXCELLENTApril-15

    Item Maintenance Reason Remarks

  • 7/24/2019 Test Program Famida

    2/2

    Months Hours Jan-15 Feb-15 Mar-15 Apr-15 May-15 Jun-15 Jul-15 Aug-15 Sep-15 Oct-15 Nov-15 Dec-15PMS No. Unit / System Unit / System P I C Last Maint. Date

    Running

    Hours

    IntervalEst. Next Due

    2015

    Date : Date : Date :

    LF- E 035/DES 2012 Written by :HST Approved by : VP / DPA Retention Period : 1 Year

    Chief Engineer Master Technical Superintendent