ISO/IEC17025 Accredited Lab. Report No: LVD1005211 File reference No: 2010-05-20 Applicant: Shenzhen Ruizi Light Electricity Technology Co., Ltd Product: LED TUBE Model No: L03-1609F, L03-1618F, L03-1624F, L03-1212F, L03-1224F Brand Name: Test Conclusions: The report is organized on the reports submitted by clients the test data as followings and found in compliance with LVD Directive 2006/95/EC. Approved By White Liu Manager Dated: May 20 , 2010 Test Conclusions appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at TIMEWAY TECHNOLOGY DEVELOPMENT LIMITED (HONG KONG) Rm. 1803, King Centre, No.23 Dundas Street, Mongkok, Kln. HONG KONG Tel (852) 2626 1885 Fax (852) 3012 1422

Test Conclusions - DIYTrade

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

ISO/IEC17025 Accredited Lab. Report No: LVD1005211 File reference No: 2010-05-20 Applicant: Shenzhen Ruizi Light Electricity Technology Co., Ltd Product: LED TUBE Model No: L03-1609F, L03-1618F, L03-1624F, L03-1212F, L03-1224F Brand Name:

Test Conclusions: The report is organized on the reports submitted by

clients , the test data as followings and found in compliance with LVD Directive 2006/95/EC.

Approved By

White Liu Manager Dated: May 20 , 2010 Test Conclusions appearing herein relate only to the sample tested

The technical reports is issued errors and omissions exempt and is subject to withdrawal at

TIMEWAY TECHNOLOGY DEVELOPMENT LIMITED (HONG KONG)

Rm. 1803, King Centre, No.23 Dundas Street, Mongkok, Kln. HONG KONG Tel (852) 2626 1885 Fax (852) 3012 1422

vivian
新建图章

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 2 of 26

Special Statement:

The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19.

The testing quality system of our laboratory meet with ISO/IEC 17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC.

Our test facility is recognized, certified, or accredited by the following organizations: CNAL-LAB Code: L2292 The Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for

testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories.

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 3 of 26

TEST REPORT

EN 60968:1990+A1:1993+A2:1999

Ballasted lamps for general lighting services-Safety requirements

EN62031:2008

LED modules for general lighting-Safety specifications

Report reference No..…..……: LVD1005211

Complied by (+signature)..… : Pigeon. Zhang

Approved by (+signature)…...: White. Liu

Date of issue………...………: 2010-05-20

Testing Laboratory..…………: TIMEWAY TECHNOLOGY DEVELOPMENT LIMITED(HONG KONG)

Address………………..…….: Rm. 1803, King Centre, No.23 Dundas Street, Mongkok, Kln. HONG KONG

Testing Location…..………...: Timeway Lab

All tests are performed at…....: Shenzhen Timeway Technology Consulting Co., Ltd.

Address………………….…..: East 5/block 4, Anhua Industrial Zone, No.8 Tairan Rd. Chegongmiao, Futian District, Shenzhen China

Applicant…………..…….…..: Shenzhen Ruizi Light Electricity Technology Co., Ltd Address…………..………….: Building A, No.8 East Of Shangxue Science & Technology City, Biantian, Longgang Shenzhen China. Standard………..…..…..…....: EN 60968:1990+A1:1993+A2:1999 EN 62031:2008

Test procedure……...…...…...: LVD

Non_ standard test method….: N/A

Name of test object…..……...: LED TUBE

Rating……...………………...: 100-240V~, 22W, 50/60Hz

Brand Name…..….………….:

Basic model…………………: L03-1618F

Addition model……………..: L03-1609F, L03F-1624F, L03-1212F, L03-1224F

Manufacturer….……………..: Shenzhen Ruizi Light Electricity Technology Co., Ltd Address……..…..…………...: Building A, No.8 East Of Shangxue Science & Technology City, Biantian, Longgang Shenzhen China.

vivian
新建图章
vivian
新建图章

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 4 of 26

Possible test case verdicts: --test case does not apply to the test object……….. : N (.A.) --test object does meet the requirement……………: P(ass) --test object does not meet the requirement……….. : F (ail)

General remark: The test results presented in this report relate only to the object tested. “See remark #” refers to one remark appended to the report. “See appended table” reference to a table appended to the report This report shall not be reproduced except in full without the written approval of the testing Lab. The differences between different models : see the statement

Statement:

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 5 of 26

EUT LABEL:

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 6 of 26

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 7 of 26

Part 1:EN 60968:1990+A1:1993+A2:1999

1 Scope P

2 Definitions P

3 General requirement and general test requirements P

3.1 Self-ballasted lamps shall be so designed and constructed that in normal use they function reliably and cause no danger to the user or surroundings.

P

3.2 All measurements unless otherwise specified, are carried out at rated voltage and frequency and in a draught-proof room at (25±1)

P

3.3 Self-ballasted lamps are non repairable, factory sealed units. They shall not be opened for any tests.

P

4 Marking P

4.1 Lamps shall be clearly and durably marked with the following mandatory markings:

P

1) Maker’s name/responsible vendor’s name/trade mark/ identification mark

P

2) Rated voltage or voltage range 100-240V~ P

3) Rated wattage (marked “W” or “watts”). 22W P

4) Rated frequency (marked in “Hz”). 50/60Hz P

4.2 The addition information shall be given either on the lamp or packing or installation instructions.

P

1) Lamp current. P

2) Burning position if restricted. N

3) The attention for the increased weight may reduce the mechanical stability of certain luminaires.

N

4) The lamps are not suitable for dimming, the symbol “ ” may be used.

Marked on the lamp P

4.3 Compliance is checked by the following: P

1) Presence and legibility of the marking required in Sub-clause 4.1 – by visual inspection.

P

2) Durability test (water and petroleum spirit) Rubbing 15s.

The marking is legible

P

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 8 of 26

after this test.

3) Availability of information required in Sub-clause 4.2 – by visual inspection.

P

5 Interchangeability. P

5.1 Interchangeability shall be ensured by the use of caps in accordance with IEC Publication 61-1.

P

5.2 Compliance of the combination of cap and bulb is checked by use of gauges for checking the dimensions controlling interchangeability in accordance with Table I.

P

5.3 Self-ballasted lamps, when capped either B22d or E27 shall have a mass not exceeding 1 kg and shall not impart a bending moment, at the lampholder, of more than 2Nm.

N

6 Protection against electric shock P

No internal metal parts or live metal parts of lamp cap are accessible when the lamp is installed in a lampholder according to Publication 238.

No provided N

Lamps with Edison screw caps shall be so designed that they comply with the requirements for inaccessibility for general lighting service lamps.

N

Lamps with B22 or B15 caps are subject to the same requirements as normal incandescent lamps with this cap.

N

External metal parts other than current-carrying metal parts of the cap shall not or become live.

The live parts are sealed by the plastic cap of the

lamp.

The external metal parts cannot become live.

P

Checked by means of insulation resistance and electric strength test.

P

7. Insulation resistance and electric strength after humidity

treatment. P

7.1 Insulation resistance P

The lamp shall be conditioned for 48h in a cabinet containing air with a relative humidity.

93%,30 P

Insulation resistance shall be measured in the humidity cabinet. See appended table P

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 9 of 26

7.2 Electric strength P

The same parts as specified above shall withstand a voltage test for 1 min with an a.c. voltage as follows:

P

-- ES caps: between accessible parts and parts of screw caps (accessible parts of insulating material are covered with metal foil):

N

Type HV (220V to 250V): 4000V r.m.s. 4000V AC, 60S P

Type BV (100V to 120V): 2U+1000V. (U=rated voltage) N

-- Bayonet caps: between shell and contacts. N

8 Mechanical strength P

Torsion resistance P

B22d………………………………………………………...3 Nm N

B15d……………………………………………………..1.15 Nm N

E27..………………………………………………………...3 Nm N

E14..……………………………………………………..1.15 Nm N

In the case of uncemented caps, relative movement between cap and bulb is permitted provided it does not exceed 10°.

N

The sample shall comply with the requirements of accessibility in the clause 6.

P

9 Cap temperature rise P

The cap temperature shall not exceed the values mentioned below when measured under the conditions specified in IEC 60360.

See appended table P

Measurement shall be carried out at rated voltage. If the lamp is measured at the lamp is marked with a voltage range it shall be measured at limits of the voltage of that range.

N

For lamp with a wide range, the measurement shall be made at the highest value of the range.

See appended table P

10 Resistance to heat P

The insulating material parts against electric shock, and parts of insulating material retaining live parts in position shall be sufficiently resistant to heat.

P

Ball- pressure test in heating cabinet at a temperature of (25±5) in excess of the operating temperature of relevant part

See appended table P

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 10 of 26

according to clause 9.

With minimum of 125 for parts retaining live parts in position. P

With minimum of 80 for other parts. P

After the ball-pressure test, the diameter of the impression shall not exceed 2 mm.

<2mm P

11 Resistance to flame and igniton P

Glow-wire test 650 for 30S P

Flame test 30S P

12 Fault conditions P

Protection exist when apparatus under fault condition P

Each of the following fault condition is applied in turn. P

Only one component at a time is subjected to a fault condition. P

a) in a switch-start circuit, the starter is short-circuited. No starter in this lamp N

b) short-circuit across capacitors See appended table P

c) the lamp does not start, because one of the cathodes is broken. See appended table P

d) the lamp does not start, although the cathode circuits are intact (de-activated lamp).

See appended table P

e) the lamp operates, but one of the cathodes is de-activated or broken (rectifying effect).

See appended table P

f) opening or bridging other points in the circuit where the diagram indicates that such a fault condition may impair safety.

N

In the case of fault conditions a), b) or f), compliance is check by operating at a voltage between 90% and 110% of the rated voltage.

P

Or in case of a voltage range, at a voltage between 90% and 110%of the mean voltage of that range until stable conditions have been reached, then introducing the fault condition.

P

In the case of fault conditions c), d) or e), the same operating conditions apply but the fault condition is introduced at the start of the test.

N

The sample is then tested a further 8h. No sample tested for 8 hours

N

The lamp shall not catch fire, or produce flammable gases and P

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 11 of 26

live part shall not become accessible.

To check if gases liberated from component parts are flammable or not, a test with a high-frequency spark generator is made.

No any gas liberated from the lamp in the

fault conditions specified in this clause.

P

To check if accessible parts have become live, a test in accordance with clause 6 is made.

P

The insulation resistance is checked with a d.c. voltage of approximately 1000V.

See appended table. P

APPENDIX --

Annex ZA Other international publications quoted in this standard with the references of the relevant European publications.

N

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 12 of 26

Part 2: EN62031:2008

4 General requirements P

5 General test requirements P

Unless otherwise specified, the tests shall be carried out at an ambient temperature of 10 and 30

P

If the light output has detectably changed, the module shall not be used for further tests

--

For SELV-operated LED modules, the requirements of IEC 61347-2-13, Annex I, apply additionally.

N

6 Classification P

Built-in N

Independent N

Integral P

7 Marking P

7.1 Mandatory marking for built-in or independent modules

a) Mark of origin P

b) Model number P

c) Rated supply voltage(s), or voltage range P

Supply frequency P

Rated input power or power range P

d) Nominal power N

e) Indication of position and purpose of the connections N

f) Value of tc N

g) For eye protection Comply with IEC 62471:2006. no hazard.

Class I

P

h) Mark of built-in module N

7.2 Location of marking On sample body P

7.3 Durability and legibility of marking For15 s with a piece of smooth cloth dampened

with water.

Not remove and Legible

P

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 13 of 26

after the test

8 Terminals N

8(14) Screw terminals to EN 60598-1, Section 14 . N

General N

Definitions N

General requirements and basic principles N

Mechanical tests N

8(15) Screwless terminal to EN 60598-1, Section 15 N

General N

Definitions—Screwless terminals N

General requiremnets N

General instructions on tests N

Terminals and connections for internal wiring N

Electrical test N

Terminals and connections for external wiring N

Mechanical Tests N

Electrical tests N

8 For connectors, the requirements of IEC 60838-2-2 shall be used, if applicable.

N

9 Provisions for protective earthing. N

9(9) The requirements of IEC 61347-1, Clause 9, apply. Class II N

Earthing terminals shall comply with the requirements of IEC 61347-1, clause 8.

N

The electrical connection/clamping means shall be adequately locked against loosening.

N

Earthing of lamp controlgear via means of fixing the lamp controlgear to earthed metal is permitted.

N

Danger of corrosion N

Material suitable N

Test for the lamp controlgear with conductors for protective earthing provided by tracks on printed circuit boards and each of

N

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 14 of 26

the accessible metal parts in turn.

10. Protection against accident contact with live parts. P

10(10.1) Live parts not accessible P

Adequate mechanical strength P

Use of tool required 10N P

The accessible live part is checked by a test finger. P

10 (10.2) Provision of discharge device (uF, V) <0.5uF N

11. Moisture resistance and insulation P

11 (11) The requirements of IEC 61347-1, Clause 11, apply.

Humidity test condition 30, 93% P

After humidity test; no appreciable damage No hazard P

Insulation resistance condition DC500V, 1min

Insulation resistance after humidity test: P

-- Live parts of different polarity (MΩ): >4 MΩ P

-- Live parts and external parts (MΩ): >4 MΩ P

12 Electric strength --

12(12) The requirements of IEC 61347-1, Clause 12, apply. P

a) between live parts of different polarity which are or can be separated

1480V, 1min P

b) between live parts and external parts, including fixing screws According to EN60968:2000

4000VAC for 60S

P

c) between live parts and control terminals, where relevant No part N

13 Fault conditions --

13.1 Not impair safety when operated under fault conditions. The requirements of IEC 61347-1, Clause 14, apply.

See the ANNEX P

13.2 Overpower condition P

14 Conformity testing during manufacture P

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 15 of 26

See Annex C. P

15 Construction --

Wood, cotton, silk, paper and similar fibrous material shall not be used as insulation.

P

16 Creepage distances and clearances --

16(11) The requirements of IEC 60598-1, Section 11, apply.

This section specifies minimum requirements for creepage distances and clearances in luminaires.

P

Working voltage (V)……………………………………………...: 100-240V P

Voltage form ~ P

PTI <600 P

Rated pulse voltage (KV)………………………………………...: N

(1) Current-carrying parts of different polarity: cr (mm); cl (mm): Basic insulation

>2.5 mm

P

(2) Current-carrying parts and accessible parts: cr (mm); cl (mm): P

(3) Parts becoming live due to breakdown of basic insulation and metal parts: cr (mm); cl (mm)……………………………………:

N

(4) Outer surface of cable where it clamped and metal parts: cr (mm); cl (mm)……………………………………………………:

N

(5) Current-carrying parts of switches and metal parts, after removal of insulation: Cr (mm); cl (mm)………………………...:

N

(6) current-carrying parts and supporting surface:

cr (mm); cl (mm)…………………………………………………:

N

17 Screws, current-carrying parts and connections --

17(17) The requirements of IEC 61347-1, Clause 17, apply

Compliance is checked by inspection and the tests of 4.11 and 4.12 of Clause 4 of IEC 60598-1

N

Electrical connections shall be so designed that contact pressure is not transmitted through insulating material

N

Self-tapping screws N

Thread-cutting screws N

Self-tapping screws may be used to provide earth continuity N

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 16 of 26

Screws and rivets which serve as electrical as well as mechanical connections shall be locked against loosening

N

Current-carrying parts shall be of copper, an alloy containing at least 50 % copper, or a material having at least equivalent characteristics

N

Current-carrying parts shall not be in direct contact with wood N

Electro-mechanical contact systems N

Screws and mechanical connections, the failure of which might cause the luminaire to become unsafe, shall withstand the mechanical stresses occurring in normal use

N

Screws transmitting contact pressure, screws which are operated when mounting or connecting the luminaires and having nominal diameter less than 3 mm, shall screw into metal

N

Screwed and other fixed connections between different parts of luminaires shall be made in such a way that they do not work loose through such torsion, bending stresses, vibration

N

Screwed glands N

18 Resistance to heat, fire and tracking --

18(18) The requirements of IEC 61347-1, Clause 18, apply.

Parts retaining live parts in position or providing protection

against electric shock

PCB certificated by UL. P

resistant to flame and ignition/fire P

glow-wire test P

needle-flame test P

Lamp controlgear intended for building into luminaires other than ordinary

N

19 Resistance to corrosion --

19(19) The requirements of IEC 61347-1, Clause 18, apply.

The ferrous parts shall be adequately protected against rusting. P

Compliance is checked by the test of 4.18.1 of Clause 4 of IEC 60598-1.

P

Protection by varnish is deemed to be adequate for the outer surfaces.

N

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 17 of 26

Table: list of critical components

Part Name Manufacturer Type/model Rating Mark(s) of conformity

Plastic enclosure

FORMOSA CHEMICALS & FIBRE CORP PLASTICS DIV

AG15AJ V-0, 130 UL:E162823

Internal wire NIZING ELECTRIC CO LTD

1332 200 , 300 Vac UL:E215834

PCB GOLDENMAX INTERNATIONAL

TECHNOLOGY LTD

FR-4 V-0, 130 UL: E224772

LED EVELIGHT 3020 -- --

NTC1 Gaoli Electronic Branch of

Huagong Tech Co. Ltd.

MZ8-B4R7MX2220 471K VDE 40020125

X capacitor Shenzhen Su Rong Capacitors Co., Ltd. MPX/MKP 0.1uf/275V VDE:40008924

Fuse Shenzhen Great Electronics Co. Ltd. RXF 10R±5%, 1W VDE 40026608

C2 CBB shenzhen surong

capacitors co., ltd

CBB21 0.22uF/400V Test with appliance

L4 SHENZHEN TIANHUAXUN

ELECTRONIC CO.,LTD EFD-20 Class B Test with appliance

L4-winding QING YUAN SHI CHANGFA ENAMELLED WIRES MATERIAL OF

COPPER CO LTD

2UEW-130 130DEG

UL E241437

L4-bobbin CHANG CHUN PLASTICS CO LTD

EC-15G V-0, 130deg UL E59481(S)

L4-insulation paper

JINGJIANG JINGYI ADHESIVE PRODUCT

CO LTD -- 13MM 130deg UL E246950

L4-dip HANG CHEUNG PETROCHEMICAL LTD 8562(a) MW28, 155deg UL E200154

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 18 of 26

5. Interchangeability N

Parts of cap: G13

Compy With Required gauge (mm)

Note: N/A

5 bending moment N

Model No Mass ( g ) Length ( cm ) bending moment(N.m)

Limit(N.m)

-- -- -- -- --

7.1 TABLE: insulation resistance measurements P

Insulation resistance R between R (MΩ) Limit

Live part and enclosure >4 4

Note: Test voltage:500V Test time:1min

7.2 TABLE: electric strength measurements P

Test voltage applied for : Test voltage (V) Breakdown:( V)

Part 1: EN 60968:1990+A1:1993+A2:1999

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 19 of 26

Live part and enclosure 4000 No

Note: Test time:1min

9 Table: temperature rise measurements

Un (V)/F(Hz) In (A) Pn (W) Pout (W)

254.4/60 0.115 22.74 --

Operating conditions:

Normal condition

Temperature rise dT of part/at: Measure temperature () Maximum temperature ()

C2 82.6 105

C3 82.0 105

L1 73.8 130

CX2 75.6 85

C1 77.3 105

L4 95.9 130

PCB near C4 96.4 130

Plastic insulation near Pins 62.7 Reference

Metal enclosure 54.4 70

Plastic enclosure 38.4 Reference

Ambient temperature 28.5

Temperature rise dT of winding: R1 (Ω) R2 (Ω) dT (K) Required dT(K) Insulation class

Remarks:

12 Table: Fault condition tests P

Rated voltage (v) …………………………………………………….…: AC100-240V --

Rated input (w) …………………………………………………………: 22 --

Room temperature ()……………………………………………..…..: 25 --

No Component Fault Test voltage Test time Fuse No Fuse current Result

1 C3 SC 254.4 1S F1 0 The fuse opened, no hazard, no damage.

2 C5 SC 254.4 1S F1 0 THE .

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 20 of 26

3 C2 SC 254.4 1S F1 0 The LED TUBE shut down. No damaged,

The fuse opend

4 LED driver

output

SC 264 1s F1 0 The LED TUBE shut down. No damaged, no

hazard.

12 TABLE: insulation resistance measurements P

Insulation resistance R between R (MΩ) Limit

Live part and enclosure(test voltage : 1000V) >4 4

Note:

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 21 of 26

Part 2:EN62031:2008

11 TABLE: insulation resistance measurements P

Insulation resistance R between R (MΩ) Limit

Live part and enclosure >4 4

Note: Test voltage:500V Test time:1min

12 TABLE: electric strength measurements P

Test voltage applied for : Test voltage (V) Breakdown:( V)

L and N(open the fuse) 1480 No

Note: Test time:1min

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 22 of 26

EUT Schematics:

PCB Layout:

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 23 of 26

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 24 of 26

Information:

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 25 of 26

Appendix

Photo of the product

EN 60968:1990+A1:1993+A2:1999 EN 62031:2008 CL. Requirement of the test Result--Remark Verdict

Report No.: LVD1005211 Page 26 of 26

Appendix

Photo of the product

-End of the report-