TerminatorTM ZT-AmbientThermostat Connection Kit

INSTALLATION PROCEDURES

Page 2: TerminatorTM ZT-Ambient

TerminatorTM ZT-Ambient Thermostat Connection Kit

The following installation procedures are suggested guidelines for the installation of the Terminator ZT-Ambient Kit. For translations other than English and local language translation provided here, please contact Thermon. The English language installation procedure shall govern.

Kit Contents

Receiving, Storing and Handling

1. Inspect materials for damage incurred during shipping.

2. Report damages to the carrier for settlement.

3. Identify parts against the packing list to ensure the proper type and quantity has been received.

4. Store in a dry location.

Certifications/Approvals

Dimensions

Warnings • Due to the risk of electrical shock, arcing and

fire caused by product damage or improper usage, installation or maintenance, a ground-fault protection device is required.

• Installation must comply with Thermon requirements (including form PN 50207U for Ex systems) and be installed in accordance with the regulations as per the norm EN IEC 60079-14 for hazardous areas (where applicable), or any other applicable national and local codes.

• Component approvals and performance ratings are based on the use of Thermon specified parts only.

• De-energize all power sources before opening enclosure.

• Avoid electrostatic charge. Clean only with a damp cloth.

• Individuals installing these products are responsible for complying with all applicable safety and health guidelines. Proper Personal Protective Equipment (PPE) should be utilized during installation. Contact Thermon if you have any additional questions.

• Consult the manufacturer for dimensional information on the flameproof joints for repair.

2

321

4190 mm

50 mm

155 mm

200 mm

205 mm

3 mm8 mm

28 mm

Item Quantity Description

1 1 Wall Mount Assembly Support Cap with O-ring Threaded Grommet Compressor Grommet Support Base with O-ring Junction Box Base with O-ring 2xM25-blind & 1 Dust Cap Nut Thermostat with terminal Blocks Bracket (3x) M5 Screws & Lock Washers

2 1 Junction Box Lid

3 1 Banding

4 1 Junction Box Cord

Tools Required

FMG 10.0022X Ex eb IIC T6, Ex tb IIIC T85°C

II 2 G Ex eb T6, II 2 D Ex tb IIIC T85°C FM 10ATEX0058X1725

1725 II 2 G Ex eb mb IIC T4-T6, FM 10ATEX0058X

IP66

-50°C ≤ Ta ≤ + 50°C

IECEx FMG 10.0022X Ex eb mb IIC T4-T6

Do not open while energized. See installation ins

truct

ions

.

Term

inator ZT-Am

b

Label PN 27674

1Ex e mb IIC «T6...T4» Gb X

№ TC RU.C-US.ГБ08.В.02034

Ex e mb IIC T4…T6 Max. 250 Vac 16-AV4BO-0054

For u

se as a control thermostat with

wi

th Thermon heating cable systems

IP66 -60°C ≤ Ta ≤ +55°C Ordinary & Hazardous Locations

Page 3: TerminatorTM ZT-Ambient

INSTALLATION PROCEDURES

3

Switched L1

2 L1 N4PE

PE

Mounting Method 1: Secure wall mount bracket to mounting surface using pipe band provided with kits.

1a. 1b.Mounting Method 2: Secure wall mount bracket to mounting surface using customer supplied screws, flat washers, and nuts.

2.Remove M25 dust cap. Install M25 gland (order separately) blind plug. Install power/control cable.

3. Install complete system wiring. Terminal set screws shall be tightened to a torque value of 1.4 Nm (12.4 lb-in). See Step 4 for wiring details. Set thermostat at desired set point (Winterization=5°C).

4.Wiring Details: Thermostat Connection. 5. Install junction box lid and twist hand tight. Insert screwdriver into ratchet slots located on side of junction box base.

6.Use screwdriver to ratchet on junction box lid. Lid will rotate 30 degrees. To remove lid, repeat steps 14 and 15 but in the opposite direction.

1725 II 2 G Ex eb mb IIC T4-T6, FM 10ATEX0058X

IP66-50°C ≤ Ta ≤ + 50°C

IECEx FMG 10.0022X Ex eb mb IIC T4-T6

Do not open while energized. See installation instructi

ons.

Term

inator ZT-Amb

Label PN 27674

1Ex e mb IIC «T6...T4» Gb X№ TC RU.C-US.ГБ08.В.02034

Ex e mb IIC T4…T6 Max. 250 Vac 16-AV4BO-0054

For use as a control thermostat with

with Thermon heating cable systems

1725 II 2 G Ex eb mb IIC T4-T6, FM 10ATEX0058X

IP66-50°C ≤ Ta ≤ + 50°C

IECEx FMG 10.0022X Ex eb mb IIC T4-T6

Do not open while energized. See installation instructi

ons.

Term

inator ZT-Amb

Label PN 27674

1Ex e mb IIC «T6...T4» Gb X№ TC RU.C-US.ГБ08.В.02034

Ex e mb IIC T4…T6 Max. 250 Vac 16-AV4BO-0054

For use as a control thermostat with

with Thermon heating cable systems

Page 4: TerminatorTM ZT-Ambient

European Headquarters: Boezemweg 25 • PO Box 205 • 2640 AE Pijnacker • The Netherlands • Phone: +31 (0) 15-36 15 370 Corporate Headquarters:100 Thermon Dr • PO Box 609 San Marcos, TX 78667-0609 • Phone: 512-396-5801 • 1-800-820-4328

For the Thermon office nearest you visit us at . . . www.thermon.com

© Thermon, Inc. • Printed in U.S.A. • Information subject to change.Form PN50874U-0417