RH511 Temperature/Relative Humidity Non-contact Infrared/Thermocouple Handheld Meter & Logger with Wireless Temp/RH Probe Option omega.com e-mail: [email protected] For latest product manuals: omegamanual.info Shop online at User’s Guide TM

Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

  • Upload
    others

  • View
    10

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

RH511Temperature/Relative Humidity

Non-contact Infrared/ThermocoupleHandheld Meter & Logger

with Wireless Temp/RH Probe Option

omega.com e-mail: [email protected]

For latest product manuals:omegamanual.info

Shop online at

User’s GuideTM

Page 2: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Servicing North America:U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047ISO 9001 Certified Stamford, CT 06907-0047 USA

Toll Free: 1-800-826-6342 TEL: (203) 359-1660FAX: (203) 359-7700 e-mail: [email protected]

Canada: 976 BergarLaval (Quebec), H7L 5A1 CanadaToll-Free: 1-800-826-6342 TEL: (514) 856-6928FAX: (514) 856-6886 e-mail: [email protected]

For immediate technical or application assistance:U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA®

Customer Service: 1-800-622-2378/1-800-622-BEST®

Engineering Service: 1-800-872-9436/1-800-USA-WHEN®

Mexico/ En Español: 001 (203) 359-7803 FAX: 001 (203) 359-7807Latin America: [email protected] e-mail: [email protected]

Servicing Europe:Benelux: Managed by the United Kingdom Office

Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21FAX: +31 20 643 46 43 e-mail: [email protected]

Czech Republic: Frystatska 184733 01 Karviná, Czech RepublicToll-Free: 0800-1-66342 TEL: +420-59-6311899FAX: +420-59-6311114 e-mail: [email protected]

France: Managed by the United Kingdom OfficeToll-Free: 0800 466 342 TEL: +33 (0) 161 37 29 00FAX: +33 (0) 130 57 54 27 e-mail: [email protected]

Germany/Austria: Daimlerstrasse 26D-75392 Deckenpfronn, GermanyToll-Free: 0800 6397678 TEL: +49 (0) 7056 9398-0FAX: +49 (0) 7056 9398-29 e-mail: [email protected]

United Kingdom: OMEGA Engineering Ltd.ISO 9001 Certified One Omega Drive, River Bend Technology Centre, Northbank

Irlam, Manchester M44 5BD United KingdomToll-Free: 0800-488-488 TEL: +44 (0) 161 777-6611FAX: +44 (0) 161 777-6622 e-mail: [email protected]

OMEGAnet® Online Service Internet e-mailomega.com [email protected]

It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMIregulations that apply. OMEGA is constantly pursuing certification of its products to the European NewApproach Directives. OMEGA will add the CE mark to every appropriate device upon certification.The information contained in this document is believed to be correct, but OMEGA accepts no liability for anyerrors it contains, and reserves the right to alter specifications without notice.WARNING: These products are not designed for use in, and should not be used for, human applications.

Page 3: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Table of ContentsSection PageSection 1 - Introduction ................................................................................ 1-1

Section 2 - Operation ..................................................................................... 2-1

Section 3 - Wireless Operation .................................................................... 3-1

Section 4 - Software Configuration ............................................................ 4-1

Section 5 - Specifications ............................................................................. 5-1

Section 6 - Error Codes .................................................................................. 6-1

Section 7 - Statement on FCC and CE Marking ....................................... 7-1

RH511 Meter

i

Page 4: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

RH511 Meter

ii

List of Figures

Section Figure Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page

1 1-1 Custom Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1

2 2-1 General Dimensions and Locations of Key Features . . . . . 2-1

2 2-2 Location of Battery Compartment & Polarities . . . . . . . . . 2-2

2 2-3 Main Function Flow Chart . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3

2 2-4 Additional Function Flow Chart . . . . . . . . . . . . . . . . . . . . . 2-7

2 2-5 Wireless Functional Flow Chart . . . . . . . . . . . . . . . . . . . . . . 2-8

2 2-6 General Dimensions Of Temperature/RH Probe & Descriptions . . . . . . . . . . . . . . . 2-9

2 2-7 Infrared Optical Field of View . . . . . . . . . . . . . . . . . . . . . . . 2-9

2 2-8 Positioning Infrared Target Temperature . . . . . . . . . . . . . 2-10

3 3-1 Model CTXL-PT Series Wireless/Temperature/RH TransmitterGeneral Dimensions, Labels, and Descriptions . . . . . . . . . 3-1

3 3-2 Model CTXL-PT Battery Location . . . . . . . . . . . . . . . . . . . . . 3-1

3 3-3 General Dimensions, Mounting Bracket Plate, CTXL-PT . . . 3-2

3 3-4 Wireless Transmitter Mounting Bracket Assembly . . . . . . 3-2

3 3-5 Wireless Transmitter Bracket With 1/4-20 Mounting Screw For Tripod Mount . . . . . . . 3-3

3 3-6 Wireless Transmitter Bracket With DIN Rail Mounting Assembly . . . . . . . . . . . . . . . . . . . . 3-3

4 4-1 Wireless Transmitter, Main Menu . . . . . . . . . . . . . . . . . . . . 4-1

4 4-2 Wireless Receiver (Meter), Main Menu . . . . . . . . . . . . . . . . 4-2

4 4-3 Settings Menu (Transmitter/Receiver) . . . . . . . . . . . . . . . . .4-3

Page 5: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Package InspectionRemove the packing list and verify that you have received all your equipment. Ifyou have any questions about the shipment, please call our Customer ServiceDepartment at 1-800-622-2378 or 203-359-1660. We can also be reached on theInternet at omega.com, e-mail: [email protected]

When you receive the shipment, inspect the container and equipment for anysigns of damage. Note any evidence of rough handling in transit. Immediatelyreport any damage to the shipping agent.

The carrier will not honor any damage claims unless allshipping material is saved for inspection. After examiningand removing contents, save packing material and carton inthe event reshipment is necessary.

The following items are supplied with the RH511 product:

• RH511 Temp/RH/IR/TC Meter

• Temp/RH Probe with 6 feet of Extension Cable, or One Wireless Temp/RHProbe (CTXL-PT series)

• Universal 9Vdc Adapter

• Six AA size Lithium Batteries

• One USB Cable

• One Mini Camera Tripod

• Software CD

• Soft Carrying Case

• Instruction Manual

RH511 Meter 1

iii

Page 6: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

NOTES:

RH511 Meter1

iv

Page 7: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Section 1 - IntroductionModel RH511 is a handheld/benchtop meter that can measure & displayambient temperature, relative humidity, non-contact infrared temperature, anddual K type thermocouple temperatures.

RH511 comes with a custom backlit LCD. The LCD can display three parameterssimultaneously. It also comes with a membrane keypad to operate the unit.

RH511 has built-in wireless capability. It acts as a wireless receiver when usedwith our wireless temperature/RH transmitter, model CTXL-PT.

RH511 has a built-in laser sighting feature used as an aiming tool to measurenon-contact target temperatures. The laser beam is switchable between laser dotand circle. The laser dot indicates the center of the target temperature. The lasercircle indicates the area of the target that is being measured which is the opticalfield of view of the device.

RH511 operates from 6 AA size batteries. It also has 9Vdc adapter input and USBPC interface. The DC adapter is used for long term measurement and display.The USB port is used to configure the unit and downloading logged data.

RH511 has logging capability where the user can log all the inputs (AmbientTemperature, Relative Humidity, Thermocouple 1, Thermocouple 2, InfraredTemperature) simultaneously. The logging interval can be set from the frontkeypad and the display menus.

RH511 comes in a plastic enclosure with a rubber boot, tilt stand, and tripodmount.

Figure 1-1 shows all the icons and digits of the custom made LCD for RH511.

Figure 1-1. Custom Display

Introduction 1

1-1

RH%

g/KgGPP

°C°FDPWB

°C°F

T1-K

MINMAX LOGHOLD LOBAT

LAL

HAL

E1

E2

E3

E4

RX

IR-T

T2-K

T1-T2

RELATIVEHUMIDITYDISPLAY

AMBIENT TEMPERATURETC1,TC1-TC2,

DP,WB DISPLAYS

TC2, INFRAREDTEMPERATURE

DISPLAYS

MAXIMUM DISPLAYICON

MINIMUM DISPLAYICON

HOLD FUNCTION ICON DATA LOGGING ICON

LOW BATTERY ICON

WIRELESSCOMMUNICATIONERROR CODES

WIRELESS DATARECEIVE ICON

HIGH & LOWALARM ICONS

WIRELESS RECEPTIONSIGNAL STRENGTH

LASER INDICATOR ICONINFRARED

TEMPERATUREICON

Page 8: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Section 2 - OperationIn order to install the 6 AA size batteries, remove the yellow rubber boot, andun-screw the battery door from the case to get to the battery compartment.Figure 2-2 shows the location and polarity of the batteries.

Figure 2-1 shows the general dimensions and location of the key features of theproduct.

Figure 2-1. General Dimensions and Locations of Key Features

Operation2

2-1

MODE

DP-WBGPP

H O L D

°F °C

MAXMIN

SETREC

TC1/TC2IRLASER

PROBE

DC POWERINPUT USB

PORTTEMP/RH9V

100mA

OMEGARH511 TEMP/RH/IR/TC

MULTI-METER & LOGGERMADE IN U.S.A

!+-

RH%

°F

°F

IR-T

!

108(4.25)

215.9(8.50)

63.5(2.50)

LASERWARNING

LABEL

RUBBERBOOT

TEMP/RHPROBE

HOLDER

DUAL K TYPETHERMOCOUPLEINPUT (SMP) SOCKETS

INFRARED LENSLASER DOT/CIRCLE SWITCHLASER DOT

LASER BEAM APERTURE (LASER CIRCLE)

95.3(3.75)

USB PORT

TEMP/RH PROBECONNECTOR

DIMENSIONS mm (in)

DC ADAPTERINPUT

BACK VIEW

TRIPODMOUNT

TILTSTAND

MEMBRANEKEYPAD

POWER LCD BACKLIGHT

LASER

WA

VE

LEN

GT

H 630-670 nm

LAS

ER

RA

DIA

TIO

N- D

O N

OT

STA

RE

INT

O B

EA

M

CLA

SS

II (2) LAS

ER

PR

OD

UC

T. CO

MP

LIES

WIT

HO

UT

PU

T<

1mW

,

IS EMITTED FROM

AVOID EXPOSURE

THIS APERTURE

CA

UT

ION

LASER RADIATION

R

FD

A 21C

FR

1040.10 & E

N 60825-1/11.2001

DC 9V

T2

T1

PRESS HERE

OM

EG

AS

CO

PE

AV

OID

EX

PO

SU

RE

LAS

ER

RA

DIA

TIO

NIS

EM

ITT

ED

FR

OM

TH

IS A

PE

RT

UR

E

LASER RADIATION - DO NOT STARE INTO BEAMOUTPUT <1 mW, WAVELENGTH 630-670 nm CLASS II (2) LASER PRODUCT, COMPLIES WITH FDA 21CFR 1040.10 & EN60825-1/11.2001

®OMEGASCOPECAUTIONLaser Warning Label

Page 9: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Figure 2-2. Location of Battery Compartment & Polarities

After installing the batteries, close the battery door, and put back on the rubberboot. If the unit comes with a wired temperature/RH probe, connect the probe tothe meter. The connection is at the bottom of the unit. The probe can be attachedto the meter via the probe holder on the side.

Operation 2

2-2

– +

–+

– +

–+

– +

–+

Page 10: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Operation2

2-3

Press the Power button to turn on the unit. The display will show therelative humidity, ambient temperature, and the non-contact infraredtemperature. Figure 2-3 shows the main functional flow chart of the unit whichis a description of the operation of the keys and the display menus.

Figure 2-3. Main Functional Flow Chart

RH%

°F

°F

IR-T

RH%

°F

°F

T1-K

IR-T

MAIN MENU

RH%

°F

°F

T1-K

T2-K

PRESS

RH%

°F

°F T2-K

RH%

°F

IR-T

RH%

HAL

RH%

LAL

RH%

°F

°F

IR-T

T1-T2

MODE

REC

REC

REC

REC

REC

ACTIVE KEYS

°F<->°C

MIN/MAX

HOLD

HOLD

HOLD

HOLD

DP-WBGPP

°F<->°C

PRESS MODE

°F<->°C

°F<->°C

PRESS MODE

PRESS MODE

°F<->°CPRESS MODE

ACTIVE KEYS

PRESS MODE

SET

PRESS MODE

SET

PRESS MODE

PRESS MODE

PRESS MODESET

10

9

8

7

6

1

2

3

4

5

Page 11: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Operation 2

2-4

Table 2-1 shows the keypad operations for the main functional flow chart of Figure 2-3.

Screen No. Mode Press Mode Press SET/REC Press Up/Hold Press Dwn/ºF<>ºC

RH/Temp/IR Go to RH/TC1/IR Start/Stop Enable/Disable Temp in °F or °CRecord

RH/TC1/IR Go to RH/TC1/TC2 Same Same Same

RH/TC1/TC2 Go to RH/TC1-TC2/IR Same Same Same

RH/TC1-TC2/IR Go to RH/Temp/TC2 Same Same Same

RH/Temp/TC2 Go to RH/Emiss/IR Same Same Same

RH/Emiss/IR Go to High Alarm ------- Increase Decrease Emissivity Emissivity

RH-High Alarm Go to Low Alarm Enable/Disable Increase High Decrease High Alarm Alarm set point Alarm set point

RH–Low Alarm Go to Recording Enable/Disable Increase Low Decrease LowInterval Alarm Alarm set point Alarm set point

Recording Go to Auto Power -------- Increase DecreaseInterval Shut off Recording Recording

Interval Interval

Auto Power Go to RH/Temp/IR Enable/Disable ----------- ----------Shut Off Power shut off

Table 2-1. Keypad Flow Chart

1

2

3

4

5

6

7

8

9

10

Page 12: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Display Screens

This is the main display screen when you power up the unit. It displays therelative humidity (%RH), ambient temperature (ºF) on the second line, andthe non-contact infrared temperature (ºF) on the third line of the display.The IR-T icon indicates IR temperature measurement. Press and holding thelaser key will turn on the laser beam and the laser icon on the display. Thereis a laser cover switch on front of the unit (See Figure 2-1) where by turningthe cover, the laser beam changes from laser circle to laser dot.

This display shows the relative humidity, thermocouple input 1 on thesecond line, and the infrared temperature on the third line of the display.

This display shows the relative humidity, thermocouple input 1 on thesecond line, and thermocouple input 2 on the third line of the display.

This display shows the relative humidity, differential thermocoupletemperature inputs 1 and 2 (T1-T2), and infrared temperature.

This display shows the relative humidity, ambient temperature, and thesecond thermocouple input (T2-K).

This display shows the relative humidity, Emissivity value for the IRmeasurement, and the infrared temperature. You can press the Up andDown arrow keys to change the Emissivity value.

This is the High alarm display screen (HAL). It shows the high alarm setpoint for the relative humidity, and the status. You can change the alarm setpoint value using the Up and Down arrow keys. You can change the alarmstatus (On/Off) by pressing the SET key.

This is the Low alarm display screen (LAL). It shows the low alarm set pointfor the relative humidity, and the status. You can change the alarm set pointvalue using the Up and Down arrow keys. You can change the alarm status(On/Off) by pressing the SET key.

This is the recording interval display screen. You can set the recordinginterval from 2 to 60 seconds using the Up and Down arrow keys. When therecording function is initiated (Pressing SET/REC key), the LOG icon willturn on, and the unit will record relative humidity, ambient temperature,infrared temperature, and the two thermocouple temperatures perrecording interval in the non-volatile memory.

This is the Auto Power shut off display screen. You can turn on/off the autopower shut off by pressing the SET key.

This is the main display screen when the data logging function is turned on.The LOG icon is shown on the display.

This display shows the maximum values of the relative humidity, ambienttemperature, and the infrared temperature during the session. You can pressthe SET key to reset the Max/Min values.

This display shows the minimum values of the relative humidity, ambienttemperature, and the infrared temperature during the session. You can pressthe SET key to reset the Max/Min values.

This is the main display screen when the Hold function is turned on. Therelative humidity, ambient temperature, and infrared temperature valuesare frozen until the Hold key is pressed again to turn off the function.

Operation2

2-5

1

7

10

14

11

12

13

8

9

6

5

4

3

2

Page 13: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

This display screen shows the relative humidity, Dew point temperature(DP) and the infrared temperature (IR-T).

This display screen shows the relative humidity, Wet Bulb temperature(WB), and the infrared temperature (IR-T).

This display screen shows the air moisture content in GPP (Grains perPound), ambient temperature, and the infrared temperature. The moisturecontent can be displayed in g/Kg when the temperatures are displayed in ºC.

This display shows the status of the wireless radio. It can be turned on/offusing the SET key. When turned on, the RH511 becomes a wireless receiverand can receive wireless signals from our wireless temperature humiditytransmitter, model CTXL-PT series.

This display shows the wireless transmission interval. It can be set to 2, 10,30, 60, 120 seconds using the Up or Down arrow keys.

This display shows the unit ID address. It can set from 00 to 99 using the Upor Down arrow keys.

Operation 2

2-6

15

20

19

18

17

16

Page 14: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Figure 2-4 shows additional functional flow chart. It demonstrates Hold, Record,and Min/Max functions, as well as displaying other parameters such as Dewpoint, Wet Bulb temperature, and Moisture content (GPP or g/Kg).

Figure 2-4. Additional Functional Flow Chart

2-7

Operation2

RH%

°F

°F

MAX

IR-T

RH%

°F

°F

IR-T

RH%

°FDP

°F

IR-T

RH%

°F

WB

°F

IR-T

GPP

°F

°F

IR-T

RH%

°F

°F

MIN

IR-T

HOLD

RH%

°F

°F

IR-T

PRESS

PRESS PRESS

PRESS

RH%

°F

°F

IR-T

LOG

PRESS

MAINMENU

HOLD

REC

MIN/MAX

MIN/MAX

PRESS MIN/MAX

DP-WBGPP

PRESS

PRESS

MIN, MAX VALUES

TO RESET

DP-WBGPP

PRESS DP-WBGPP

PRESS DP-WBGPP

ACTIVE KEYS [ ] MODE °F<->°C

SET°F<->°C

SET

SET

°F<->°C

11

112

13

14

15

16

17

Page 15: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Operation 2

2-8

Figure 2-5 shows the functional flow chart for the wireless section. This willallow you to turn on/off the radio, set the transmission interval (2, 10, 30, 60, 120seconds) and the wireless transmitter ID address (00 to 99).

Figure 2-5. Wireless Functional Flow Chart

RH%

°F

°F

IR-T

MAIN MENU

PRESS & HOLDMODE

PRESS MODE

PRESS MODE

PRESS MODE

ACTIVE KEYS

SET

for 2 seconds

1

18

19

20

Page 16: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Operation2

2-9

Figure 2-6 shows the general dimensions of the temperature/RH probe thatconnects directly to the RH511 multi-meter.

Figure 2-6. General Dimensions of Temperature/RH Probe & Descriptions

Infrared Function

Figure 2-7 shows the optical field of view of the infrared temperaturemeasurement. You can set the target emissivity from screen no. 6 Fig. 2-3. Simplyaim the infrared lens to the target object, press and hold the laser button to turnon the laser beam. The laser beam indicates either the center of the target object(Laser Dot) or the area of the target being measured (Laser circle). There is a 5/8inch offset between the center of the optical field of view and the laser beam. Itmay take a few moments for the IR reading to stabilize. For more detailsregarding laser sighting, please refer to Section 5.

Figure 2-8 shows the proper way of measuring infrared target temperature.

Figure 2-7. Infrared Optical Field of View Diagram

12.7(0.50)

54.0(2.125)

133.4(5.25)

203.2(8.0)

DINCONNECTOR

DIMENSIONS mm (in)

STRAIN RELIEF PLASTIC HANDLE ALUMINUM SENSORPROBE

TC

1/TC

2IR

LAS

ER

RH

%

°F°FIR-T

PO

WE

RLC

D B

AC

KLIG

HT

.50"@0"

1.3cm@0"

* S

PO

T D

IA.(

IN)

* S

PO

T D

IA.(

CM

)

DISTANCE: SENSOR TO OBJECT (FT)

DISTANCE: SENSOR TO OBJECT (CM)

1' 2' 3' 4' 5'

1.2"

2.4"

3.6"

4.8"

6.0"

30 60 91 122 152

* SPOT DIAMETER MEASURED AT 90% ENERGY

LINE OF SIGHT OF THE LASER BEAM

LINE OF SIGHT OF THE THERMOMETER

5/8"(1.6cm)

3.0

6.0

9.0

12

15

0'

0

D:S = 10:1

Page 17: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Operation 2

2-10

Figure 2-8. Positioning Infrared Target Temperature

Hold Function

You can initiate the hold function by pressing the Hold/Up key from thefollowing display menus:

RH/Temp/IR (Main Menu)RH/TC1/IRRH/TC1/TC2RH/TC1-TC2/IRRH/Temp/TC2

The hold function freezes the readings on the display. You can un-freeze thedisplay readings by pressing the Hold/Up key again.

Max/Min Function

RH511 keeps track of Maximum and Minimum values of Relative Humidity,ambient temperature, and the infrared temperature. From the main menu, pressthe Max/Min button to display the maximum values. Press the Max/Min buttonagain to display the minimum values. During these two display modes, you canreset the Max/Min values to the current values by pressing the Set key.

Pressing the Max/Min key again will bring you back to the main menu.

Dew Point/ Wet Bulb/ Moisture Content

RH511 calculates and displays the Dew point temperature, wet bulbtemperature, and moisture content. From the main menu, press theDP/WB/GPP key to display the Dew point temperature. The Dew point icondisplay will turn on.

Press the DP/WB/GPP key again, it will display the wet bulb temperature. Thewet bulb temperature display icon will turn on.

Press the DP/WB/GPP key again, it will display the air moisture content ineither GPP (Grains Per Pound) or g/Kg (grams per kilogram).

Press the DP/WB/GPP key again, and it will go back to the main menu.

TARGET SURFACE

FIELD OF VIEW

ACCEPTABLE UNACCEPTABLE

Page 18: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Data Logging

You can set the recording interval from one of the display menus as shown inFigure 2-3. The recording interval can be set from 2 to 60 seconds. You caninitiate logging data (Relative Humidity, Ambient temperature, Infraredtemperature, Thermocouple 1, Thermocouple 2) by pressing the SET/REC keyfrom the following display menus:

RH/Temp/IR (Main Menu)RH/TC1/IRRH/TC1/TC2RH/TC1-TC2/IRRH/Temp/TC2

The LOG display icon will turn on. The unit will log the five sets of data until theinternal memory gets full. It will then stop logging data. You can also stoplogging data at any time by pressing the SET/REC key again.

Auto Power Shutoff

The unit has an auto power shutoff feature. When this feature is turned on(Default is ON), the unit shuts down after 5 minutes if no keys are pressed tosave battery life. You can press the Power button to turn the unit back on.

If the auto power shutoff feature is turned off, the unit will stay on until the userturns the unit off by pressing the power button.

Operation2

2-11

Page 19: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Section 3 – Wireless OperationThe RH511 can communicate with our wireless temperature/RH probetransmitter model CTXL-PT series. The RH511 becomes a wireless receiver andcan receive & display temperature/RH data from the wireless probe. This optionis very helpful for applications where the probe and the meter can not bephysically connected, or the meter has to monitor multiple wireless probes.

The wireless RH511 comes in two models:RH511-W9 works with CTXL-PT-W9 915 MHz wireless probe (US & Canada)RH511-W8 works with CTXL-PT-W8 868 MHz wireless probe (Europe)

Figure 3-1 shows the general dimensions of the wireless temperature/relativehumidity transmitter (Model CTXL-PT series), labels, and descriptions.

Figure 3-1. Model CTXL-PT Series Wireless Temperature/RH Transmitter GeneralDimensions, Labels, and Descriptions

The CTXL-PT series takes one 3.6VDC lithium battery to operate. Figure 3-2shows the battery location on the board once you open the plastic case.

Figure 3-2. Model CTXL-PC Battery Location

3-1

LO-B

AT

/ER

RO

R

TX

POWEROFF

CONFIGONDC POWER

INPUT

5 V100 MA

– +

PR

OB

E

US

BP

OR

T

–W9(915MHz)

–W8(868MHz)

CTXL-PT SERIESWIRELESS

TEMPERATURE/HUMIDITYTRANSMITTER

BATTERY POWER SWITCH

DIMENSIONS mm (in)

DC ADAPTER INPUT

USB PCINTERFACEINDICATOR

TRANSMIT LEDINDICATOR

LOW BATTERY& COMM ERRORLED INDICATOR

69.9(2.75)

50.8(2.00)

54.0(2.125)

Ø.12.7(0.50)

TEMPERATURE/ HUMIDITY SENSOR PROBE

FCC LABEL

!

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference; 2) This device must accept any interference received, including interference that may cause undesired operation.

FCC ID: WR3-CTXLPTIC: 8205A-CTXLPT

PATENT PENDINGMade in U.S.A.

+– 3.6VDC LITHIUM BATT

J3

J7S1

J1D4D3

Wireless Operations 3

Page 20: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Wireless Operation3

Figures 3-3 through 3-6 show all the mounting hardware for the wirelesstemperature/RH transmitter.

Figure 3-3. General Dimension, Mounting Bracket Plate, CTXL-PT

Figure 3-4. Wireless Transmitter Mounting Bracket Assembly

3-2

LOCATIONOF CASE

MOUNTINGSCREWS CL

LC

54.0(2.125)

34.9(1.375)

3.175(0.125 DIA.)2 PLCSMOUNTINGHOLES

24.5(1.00)

63.5(2.500)

81.3(3.200)

88.9(3.500)

DIMENSIONS mm (in)

50.8(2.000)

22.9(0.090)

WIRELESS TRANSMITTER

TWO MOUNTINGCASE SCREWS

TWO 4-40 MOUNTINGBRACKET SCREWS

Page 21: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Figure 3-5. Wireless Transmitter Bracket With 1/4-20 Mounting Screw For Tripod Mount

Figure 3-6. Wireless Transmitter Bracket With DIN Rail Mount Assembly

3-3

1/4-20 FLAT HEAD SCREWWASHER & HEX NUT

TWO MOUNTINGCASE SCREWS

WIRELESS TRANSMITTER

FOUR #6 FLAT HEAD SELF TAPMOUNTING SCREWS - DIN RAIL

TWO MOUNTINGCASE SCREWS

WIRELESS TRANSMITTER

Wireless Operation 3

Page 22: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Software Configuration4

4-1

Section 4 - Software ConfigurationYou can use the Configuration software to download/erase recorded data from theRH511. You can also use the same software to change the wireless configuration ofthe RH511 (receiver), and the wireless probe transmitter, CTXL-PT.

The wireless transmitter and receiver have the following factory defaultconfiguration:Transmission time interval: 2 secondsChannel Frequency: 915 MHz (US & Canada) or 868 MHz (Europe) Unit ID: 00 (Both transmitter & receiver)

The user does not have to do any configuration to the transmitter or the receiverif the factory configuration is satisfactory. However, if the user wants to changethe configuration, then you need to run the configuration software that comeswith the unit. Through the configuration software, the user can change thetransmission interval, channel frequency and the unit ID number. First install theconfiguration software on your PC.

Configuring the Wireless Transmitter – Turn off the battery power. Connect thetransmitter to the USB port of the PC with the cable provided. Run theconfiguration software. Figure 4-1 shows the main menu of the software. Thebuttons and the menu selections are described as follows: Save – It will save the new settings to the transmitter.Read – It will read the current settings of the transmitter. It will display thecurrent temperature & relative humidity of the probe.Settings – It will take you to the communication settings menu.Frequency – You can select between 910/ 915/920 MHz frequencies.Time interval – You can select from 2 seconds up to 2 minutes.Unit ID - You can select a unit ID from 00 to 99.

Figure 4-1. Wireless Transmitter, Main Menu

Page 23: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

4-2

You can have up to a total of 100 wireless transmitters in one location withdifferent unit ID numbers, so that there will not be any conflict between any ofthe transmitters.

If you select the Broadcast option, the transmitter will transmit to any receiver inthe area at the same frequency regardless of its unit ID number. After saving thenew configuration, exit the program. Un-plug the transmitter from the USB port,turn the battery power back on and you are good to go.

Configuring the Wireless Meter (Receiver) – Connect the RH511 meter to theUSB port of the PC with the cable provided. Run the configuration software.Figure 4-2 shows the main menu of the software. The buttons and the menuselections are described as follows:Save – It will save the new settings to the meter.Read – It will read the current settings of the meter. Please note that the displayreading is grayed out since RH511 displays the current readings.Settings – It will take you to the communication settings menuFrequency – You can select between 910/915/920 MHz frequencies. Please notethat Time interval & Unit ID are grayed out since the user can change thesesettings on the RH511 meter.Upload – It will download logged data from RH511 to the PC.Erase – It will erase logged data from the RH511 meter.

Figure 4-2. Wireless Receiver (Meter), Main Menu

Software Configuration 4

Page 24: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

You can have up to a total of 100 wireless receivers (meters) in one location withdifferent unit ID numbers, so that there will not be any conflict between any ofthe receivers.

In order for a pair of wireless transmitter and receiver to communicate properly,the time interval, channel frequency and the unit ID should be the same for both.

Probe Humidity Calibration

You can calibrate the probe for humidity at 33 & 75% RH. Simply, plug in thevalues the probe reads at these two calibration points, and click “Calibrate” tocomplete the humidity calibration. This calibration applies both to the wiredprobe and the wireless probe.

Clicking “Defaults” will reset the humidity probe to the Factory calibration.

Figure 4-3 shows the settings menu for selecting the COM port, and thetemperature Engineering unit.

Figure 4-3. Settings Menu (Transmitter/Receiver)

Software Configuration4

4-3

Page 25: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Section 5 - Laser Sighting

You may receive harmful laser radiation exposure if you donot adhere to the following warnings:• Use of controls or adjustments or performance of procedures other than those specified here may result inhazardous radiation exposure.• Do not look at the laser beam coming out of the lens orview directly with optical instruments. Eye damage can result.• Use extreme caution when operating the laser sighting.• Never point the laser beam at a person.• Do not attempt to open the meter. There are no userserviceable parts inside.• Keep out of reach of all children.

5.1 DescriptionThe laser sighting is built into the handheld meter. It provides a visual indicationof the field of view of the thermometer. There is a laser switch in front of theinstrument. It switches between laser dot and circle when the laser beam isturned on. Figure 2-1 shows the laser warning label, the location of the laserdot/circle switch, and all the controls.

5.2 Operating the Laser SightingThe laser sighting provides a visual indication of the optical field of view of thethermometer when measuring non-contact temperatures. The followingprocedure lists all the steps necessary to measure non-contact temperaturesusing laser sighting:

• Set the target Emissivity from the display menus.

• Aim the optical lens to the target object.

• Press & hold the Laser key on the front membrane keypad. The laser beam willturn on, and the LCD display will show the laser icon. Once the laser key isreleased, the laser beam will turn off, and the laser icon will turn off from thedisplay.

• You can set the laser switch to laser dot or circle. The laser dot indicates thecenter of the target, the laser circle indicates the perimeter of the area of thetarget being measured. Figure 5-1 shows the two laser configurations.

• Simply release the laser key on the membrane keypad. It will turn off the laserbeam and the laser icon indication on the display.

Laser Sighting 5

5-11

CAUTION:

Page 26: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Laser Sighting5

5-12

Laser Dot Laser Circle

Figure 5-1 Two Laser Configurations

TM

Page 27: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

6-1

Specifications 6

Section 6 - SpecificationsGENERAL

Sensor Probe Relative HumidityRange: 2 to 98% RHAccuracy: 2.5% RH (15 to 85% RH @ room temperature)Resolution: 0.1% RH

Sensor Probe TemperatureRange: -20 to 70ºC (-4 to 158ºF)Accuracy: 1ºC (2ºF)Resolution: 0.1ºC or ºF

Infrared TemperatureRange: -20 to 550ºC (-4 to 1022ºF)Accuracy: 2% of Rdg or 4ºF at Emissivity of 0.95 or greater

and ambient temperature of 75ºFResolution: 1ºC or ºFOptical Field of View: 10 to 1Emissivity: Adjustable from 1.00 to 0.10 in 0.01 steps

Thermocouple Input: Two, K typesRange: -100 to 1000ºC (-148 to 1832ºF)Accuracy: 2ºC (4ºF)Resolution: 1ºC or ºFInput Connection: SMP connectorThermocouple Open: Upscale, display shows “----“

Dew Point Temperature: Set via keypad (ºC or ºF)

Wet Bulb Temperature: Set via keypad (ºC or ºF)

Moisture Content: Set via keypad (GPP, g/Kg)

Hold Function: Enable/disable via keypad

Max/Min Function: Set via keypad

Data LoggingNumber of Data Points: 8190 sets of data points per channelNumber of Channels: Five – Relative Humidity, ambient temperature,

Infrared temperature, Thermocouple 1,Thermocouple 2

Data Recording Interval: Set via keypad, 2 to 60 seconds

LCD Backlight: Set via keypad, ON for 10 seconds

PC Interface: USB, 115200 baud rate, 8-bit Data, 1 Stop bit, No Parity

Response time (Humidity): 8 seconds, 0 to 63% of final value

Power: 6 AA size 1.5V Lithium batteries, or 9 Vdc adapter

Battery Life: 250 hours, continuous (wireless turned off)150 hours, continuous (wireless turned on)

AC Adapter: Standard – 100 to 240 Vac,50-60 Hz UL, CE, FCC marking

Output Voltage: 9V @ 1.7AOutput Plug (Female): Center positive, coax 2.0/5.5/10mm

Page 28: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Specification6

6-2

Operating AmbientEnvironment: 0 to 50ºC (32 to 122ºF)

0 to 90% RH, non-condensing

General Dimensions: 101 W x 203 H x 51mm D (4 x 8 x 2")

Tripod Mount: 1/4-20 UNC

Soft Carrying Case: Standard

Weight: 650 g (1.4 lbs)

LASER SIGHTING

Wave length (Color): 630 to 670 nm (Red)

Operating DistanceLaser Dot: Up to 30 feetLaser Circle: Up to 15 feet

Max Optical Power Output: Less than 1 mW at 75ºF ambient temperature, Class II Laser product

European Classification: Class 2, EN60825-1

Maximum Operating Current: 25 mA @ 3.3V

FDA Classification: Complies with 21 CFR Chapter 1, subchapter J

Beam Diameter: 5mm

Beam Divergence: <2 mrad

Laser Configuration: Dot/circle switchable

Laser Power Switch: Laser button from the keypad

Laser Power Indicator: Laser icon on the display

Identification Label: Located on the bottom of the meter

Warning & Certification Label: Located on the left side of the meter

WIRELESS TRANSMITTER

Sensor Probe Relative HumidityRange: 2 to 98% RHAccuracy: 2.5% RH (15 to 85% RH @ room temperature)Resolution: 0.1% RH

Sensor Probe TemperatureRange: -20 to 70ºC (-4 to 158ºF)Accuracy: 1ºC (2ºF)Resolution: 0.1ºC or ºF

Transmit Time Interval: 2 seconds – default, 10 seconds,30 seconds, 1 minute, 2 minutes

Radio Frequency: ISM 915 MHz or ISM 868 MHz

RF Power Output: 5 dBm (3.16 mW)

Page 29: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

ApprovalsCTXL-PT-W9: FCC, Class A, 915 MHz (US & Canada)CTXL-PT-W8: CE, 868 MHz (Europe)RH511-W9: Receiver, 915 MHz (US & Canada)RH511-W8: Receiver, 868 MHz (Europe)

RF Link RangeOutdoor, Line of Sight: Up to 90 m (300')Indoor/urban: Up to 33.5 m (110')

PC Interface: USB, 115200 baud rate, 8-bit Data,1 Stop bit, No Parity

Operating Environment: -18 to 49°C (0 to 120°F), 2 to 98% RH

LED IndicatorsGreen LED: Transmit indication, blinks every time intervalRed LED: Low Battery and other communication error

indications

Power: One 3.6 Vdc AA size Lithium Battery,2400 mAH capacity or Optional AC adapter

Battery Life: 1 year typical at transmitting every minute6 months typical at transmitting every 2 seconds

Dimensions: 70 x 51 x 20 mm (2.75 x 2 x 0.8")

6-3

Specifications 6

Page 30: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Section 7 - Error CodesTransmitter Error Codes

The wireless transmitter uses the Red LED to provide different error informationto the user and to the wireless receiver as follows:2 Red LED Blinks means there is an RF communication error such as Framing,CRC, buffer overflow, etc.3 Red LED Blinks means that the transmitter fails to communicate with thesensor probe4 Red LED Blinks means Low Battery indication.

The highest priority error code is 2 blinks for RF communication error. Thelowest priority error code is 4 blinks to indicate low battery. If multiple errorsoccur at the same time such as bad sensor probe and low battery, thetransmitter's red LED will blink 3 times. Only when this error clears, then thetransmitter's red LED will blink 4 times to indicate the low battery. The red LEDerror reporting occurs every 30 seconds regardless of the transmission timeinterval.

Receiver (Multi-meter) Error Codes

The wireless meter basically reflects all the error codes of the wireless transmitteron the display as different icons:E1 means No good message has been received from the transmitter within 4transmission time intervals (like 4 minutes for 1 minute time interval), or 30seconds minimum. The receiver will continue to search for the transmitter’smessage 10 more minutes before deciding that the transmitter is either off, out oforder, or out of range at which point the receiver will shut itself off to conservepower.

If the wireless transmitter is back on line after 10 minutes, then the user needs toun-plug the receiver from the recorder and plug it back in to reset the wirelessreceiver.

E2 means there is an RF communication error such as Framing,CRC, buffer overflow, etc.

E3 means that the transmitter fails to communicate with thesensor probe

E4 means the transmitter’s Battery is low.

The highest priority error code is E1 for No good message from thetransmitter. The lowest priority error code is E4 to indicate transmitter’s lowbattery.

7-1

Error Codes7

Page 31: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

Statement on FCC and CE Marking 8

8-1

Section 8- Statement on FCC and CE MarkingFCC – USA & Canada

FCC ID: WR3-CTXLPTIC: 8205A-CTXLPT

This device complies with Part 15 of the FCC rules. Operation is subject to thefollowing two conditions:

1. This device may not cause harmful interference.2. This device must accept any interference received, including interference that

may cause undesired operation

Changes or modifications not expressly approved by Omega Engineering, Inc.could void user’s authority to operate this equipment.

This equipment has been tested and found to comply with thelimits for a Class A digital device, pursuant to part 15 of theFCC Rules. These limits are designed to provide reasonableprotection against harmful interference when the equipment isoperated in a commercial environment. This equipmentgenerates, uses, and can radiate radio frequency energyand, if not installed and used in accordance with theinstruction manual, may cause harmful interference to radiocommunications. Operation of this equipment in a residentialarea is likely to cause harmful interference in which case theuser will be required to correct the interference at his ownexpense.

International Usage & CE Marking (Pending)

The Wireless CTXL (868 MHz mode) Series system components are CE markedand certified for use in several European countries. Please contact OMEGA forinformation on International Regulatory Compliance for each country.

It is your (the user’s) responsibility to insure that these products are operatedwithin the guidelines here in this manual and in conformance with all local ornational regulations and laws.

PRE-CAUTIONS - Transmitter Operation

• Do not operate your wireless device outside the recommendedenvironmental limits specified in this manual.

• Do not operate your wireless device in flammable or explosiveenvironments.

• Do not operate your wireless device in medical, nuclear, or otherdangerous applications.

• No co-location with other radio transmitters is allowed. By definition, co-location is when another radio device or it's antenna is located within20 cm of your wireless device and can transmit simultaneously.

NOTE:

Page 32: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

• Do not install two wireless CTXL transmitters within 20 cm of each other.

• Do not operate your wireless transmitter closer than 20 cm to nearbypersons.

PRE-CAUTIONS - Battery Operation

Your wireless transmitter is supplied with one AA size 3.6V Lithium battery(Omega p/n OM-NOMAD-BATT). This battery is not re-chargeable. An optional5V DC adapter is available (Omega p/n UNIV-AC-100/240-5V) for permanentpower installation.

• Do not operate your wireless transmitter with any other battery otherthan what is specified in this manual.

• Do not place the battery in fire or heat the battery.

• Do not solder to or short the battery terminals

• Do not disassemble or modify the battery.

• Dispose of your discharged batteries in accordance with your local, state,and national laws.

8-2

Statement on FCC and CE Marking8

Page 33: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

NOTES:

RH511 Meter

8-3

Page 34: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

NOTES:

RH511 Meter

8-4

Page 35: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for aperiod of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) monthgrace period to the normal ONE (1) year product warranty to cover handling and shipping time. Thisensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer ServiceDepartment will issue an Authorized Return (AR) number immediately upon phone or written request.Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at nocharge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser,including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion;or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operatingconditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for anydamages that result from the use of its products in accordance with information provided byOMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by thecompany will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OFTITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITYAND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “BasicComponent” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medicalapplications or used on humans. Should any Product(s) be used in or with any nuclear installation oractivity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibilityas set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnifyOMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of theProduct(s) in such a manner.

RETURN REQUESTS/INQUIRIESDirect all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORERETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN(AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOIDPROCESSING DELAYS). The assigned AR number should then be marked on the outside of the returnpackage and on any correspondence.The purchaser is responsible for shipping charges, freight, insurance and proper packaging to preventbreakage in transit.

FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:1. Purchase Order number under which the product

was PURCHASED,2. Model and serial number of the product under war-

ranty, and3. Repair instructions and/or specific problems

relative to the product.

FOR NON-WARRANTY REPAIRS, consult OMEGAfor current repair charges. Have the followinginformation available BEFORE contacting OMEGA:1. Purchase Order number to cover the COST

of the repair,2. Model and serial number of the product, and3. Repair instructions and/or specific problems

relative to the product.OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affordsour customers the latest in technology and engineering.OMEGA is a registered tradÏemark of OMEGA ENGINEERING, INC.© Copyright 2011 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without theprior written consent of OMEGA ENGINEERING, INC.PATENT NOTICE: U.S. PAT. 5,368,392; 5,524,984; 5,727,880; 5,823,678; 5,823,679; 6,540,398, 6,614,830, 6,633,434,6,659,639 / Canada 2,114,806, 2,223,195, 2,317,734 / UK 2,320,324 / Germany G94 22 197.9; G94 22 203.7, 69435097 / EPO01065483; 01065484 / France 2,756,920, 2,767,921; 2,773,213, 2,773,214 / Holland 1,007,752 / Japan 166256.

Page 36: Temperature/Relative Humidity Non-contact Infrared ...ambient temperature, relative humidity, non-contact infrared temperature, and dual K type thermocouple temperatures. RH511 comes

M4954/0211

Where Do I Find Everything I Need forProcess Measurement and Control?

OMEGA…Of Course!Shop online at omega.com SM

TEMPERATURE�� Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies�� Wire: Thermocouple, RTD & Thermistor�� Calibrators & Ice Point References�� Recorders, Controllers & Process Monitors�� Infrared Pyrometers

PRESSURE, STRAIN AND FORCE�� Transducers & Strain Gages�� Load Cells & Pressure Gages�� Displacement Transducers�� Instrumentation & Accessories

FLOW/LEVEL�� Rotameters, Gas Mass Flowmeters & Flow Computers�� Air Velocity Indicators�� Turbine/Paddlewheel Systems�� Totalizers & Batch Controllers

pH/CONDUCTIVITY�� pH Electrodes, Testers & Accessories�� Benchtop/Laboratory Meters�� Controllers, Calibrators, Simulators & Pumps�� Industrial pH & Conductivity Equipment

DATA ACQUISITION�� Data Acquisition & Engineering Software�� Communications-Based Acquisition Systems�� Plug-in Cards for Apple, IBM & Compatibles�� Data Logging Systems�� Recorders, Printers & Plotters

HEATERS�� Heating Cable�� Cartridge & Strip Heaters�� Immersion & Band Heaters�� Flexible Heaters�� Laboratory Heaters

ENVIRONMENTALMONITORING AND CONTROL�� Metering & Control Instrumentation�� Refractometers�� Pumps & Tubing�� Air, Soil & Water Monitors�� Industrial Water & Wastewater Treatment�� pH, Conductivity & Dissolved Oxygen Instruments