Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
Temperature Measurement
Product Range
CONATEX | Alsfassener Str. 56 | D-66606 St. Wendel | Tel.: +49 68 51 . 93 39-0 | Fax: +49 68 51 . 20 76 | [email protected]
Temperature Measurement
www.conatex.dePage 2/16
Company Data CONATEXDipl.-Ing. L. Colbus GmbH
P.O. Box 1220D-66592 St.Wendel
Alsfassener Straße 56D-66606 St.Wendel
telephone: +49 (0) 6851 / 9339-0telefax: +49 (0) 6851 / 2076
email: [email protected]
VAT ID: DE138247311Tax ID number: 040/107/59124
Terms and Conditions: We will be pleased to send you our terms and conditions on request.You may also download them. (http://www.conatex.de/upload/agb_eng(1).pdf)
Trademarks: Designations in this catalog may be trademarks, the use of which by third parties for their own purposes may violate the rights of the trademark owners.
Copyright: © 2017 CONATEX Dipl.-Ing. L. Colbus GmbH, St.Wendel.All rights reserved, in particular the right of reproduction(Print, photocopy, or any other process) and disseminationas well as translation.
Content: Subject to change. Liability for errors, misprints and omissions excluded.
CONATEX | Alsfassener Str. 56 | D-66606 St. Wendel | Tel.: +49 68 51 . 93 39-0 | Fax: +49 68 51 . 20 76 | [email protected]
Temperature Measurement
www.conatex.de
Services: Our qualified service staff maintains, checks and repairs your measuring and control systems.
Within the scope of DIN EN ISO 9000 ff., we are able to issue measurement logs of your systems. The used testing and calibration equipment is regularly calibrated in connection with our own DAkkS / DKD laboratory which guarantees traceability on national standards.
Page 3/16
Works Calibration: Of course, we can also provide works calibrations with traceability to national standards for temperature ranges from -40 °C to 1200 °C and electrical quantities (multimeter, calibrators etc.)
Consulting: In all fields of measurement technology we will provide competent and fair advices. Please do not hesitate to contact us.
Points of Contact: Contact persons for sales (indoor and field service), order processing, DAkkS / DKD laboratory and service can be found on our website.
Quality Management System:
CONATEX | Alsfassener Str. 56 | D-66606 St. Wendel | Tel.: +49 68 51 . 93 39-0 | Fax: +49 68 51 . 20 76 | [email protected]
Temperature Measurement
www.conatex.dePage 4/16
DAkkS-/DKD Calibration Laboratory Calibration Equipment: For comparison measurements with temperature ranges between -40 °C and 500 °C, stirred liquid baths (water / glycol, silicone oil, saltpetre) are available.
From 200 °C up to 1200 °C, thermometers, mainly thermocouples, can be tempered in a tube furnace.
The heated inner tube of this furnace is equipped with an insert for different diameters. This ensures a good heat transfer between the thermometers.
For the comparison measurements, precise platinum resistance thermometers or platinum-rhodium thermocouples are used as references. They meet the requirements of ITS 90 and are based on national standards.
CONATEX | Alsfassener Str. 56 | D-66606 St. Wendel | Tel.: +49 68 51 . 93 39-0 | Fax: +49 68 51 . 20 76 | [email protected]
Temperature Measurement
www.conatex.dePage 5/16
1) DIN 43710 withdrawn since 1994, can no longer be used for new installations.
T1/1 Thermocouple wires, uninsulated according to DIN EN 60584-1 and DIN 437101)
Thermocouple wire types: J, L, T, U, K, N, E, S, R, B
Thermocouple wire Ø: 0,2 / 0,35 / 0,5 / 1,0 / 1,38 / 1,5 / 2,0 / 3,0 mm
Purchase or processing of precious metal scrap
T1/2 Insulated thermocouple wires according to DIN EN 60584-1
Thermocouple wire types: J, L, T, U, K, N, E
Thermocouple wire Ø: 0,2 / 0,5 / 0,8 / 1,0 / 1,38 mm
Models: single or twin conductor
Insulation: PVC max. +105 °C silicone max. +200 °C Teflon max. +260 °C fiberglass max. +400 °C special-fiberglass max. +600 °C silica-fiber max. +1000 °C ceramic-fiber max. +1200 °C
T1/3 Thermocouple elements according to DIN EN 50113
Thermocouple wire types: J, L, T, U, K, N, E, S, R, B
Thermocouple wire Ø: 0,35 / 0,5 / 1,0 / 1,38 / 1,5 / 2,0 / 2,5 / 3,0 mm
Models: form A, B, C, CI, D
CONATEX | Alsfassener Str. 56 | D-66606 St. Wendel | Tel.: +49 68 51 . 93 39-0 | Fax: +49 68 51 . 20 76 | [email protected]
Temperature Measurement
www.conatex.dePage 6/16
Thermocouple wire types: J, L, T, U, K, N, E, S, R, B
Thermowell materials: steel St 35.8, material no. 1.0305, for max. temp. of 550 °C steel St 35.8, enamelled, for max. temp. of 600 °C steel, heat resistant, material no. 1.4762, for max. temp. of 1200 °C steel, heat resistant, material no. 1.4841, for max. temp. of 1200 °C steel, heat resistant, Kanthal AF, or max. temp. of 1250 °C ceramic, porous, type C 530, for max. temp. of 1350 °C ceramic, gas-tight, type C 610, for max. temp. of 1400 °C ceramic, gas-tight, type C 799, for max. temp. of 1800 °C
Thermocouple wire types: J, L, K, N
Inset-Ø: 3,0 / 3,2 / 6,0 / 8,0 / 10,0 mm
Models: R, M
T3 Angled thermocouple assemblies
Thermocouple wire types: L, J, K, S
T2/1 Straight thermocouple assemblies according to DIN EN 50446
Models: AM, AMK, AK, AKK, BM, BMK, BK
T2/2 Measuring insets for thermocouples according to DIN 43735
Thermowell materials: form 1, iron form 3-1, iron (technically pure) form 3-2, steel, material no. 1.4772 form 3-3, steel enamelled form 3-4, GG 22, material no. 0.6022 form 3-5, titanium NT form 3-6, graphite form 3-7, iron (technically pure) with protection sleeve form 3-8, steel, SL25, 30x9 mm, material no. 1.4821 form 3-9, high duty ceramic material CO9901
CONATEX | Alsfassener Str. 56 | D-66606 St. Wendel | Tel.: +49 68 51 . 93 39-0 | Fax: +49 68 51 . 20 76 | [email protected]
Temperature Measurement
www.conatex.dePage 7/16
Materials: steel St 35.8, material no. 1.0305, for max. temp. of 550 °C steel St 35.8, enamelled, for max. temp. of 600 °C steel, heat resistant, material no. 1.4762, for max. temp. of 1200 °C steel, heat resistant, material no. 1.4841, for max. temp. of 1200 °C steel, heat resistant, Kanthal AF, for max. temp. of 1250 °C
Materials: ceramic, porous, type C 530, for max. temp. of 1350 °C ceramic, gas-tight, type C 610, for max. temp. of 1400 °C ceramic, gas-tight, type C 799, for max. temp. of 1800 °C
T4/3 Connection heads according to DIN EN 50446 and terminal blocks
Models: A, B, J
T4/1 Metal protection tube according to EN 50446
T4/2 Ceramic protection tubes and insulation parts according to DIN EN 60672
T4/4 Accessories for thermocouple assemblies and resistance thermometers
Models:
Stop flange Companion flange Threaded sleeve
CONATEX | Alsfassener Str. 56 | D-66606 St. Wendel | Tel.: +49 68 51 . 93 39-0 | Fax: +49 68 51 . 20 76 | [email protected]
Temperature Measurement
www.conatex.dePage 8/16
Thermocouple types J, L, T, U, E, K, N, R, S, B
Thermocouple types T, U, L, J, K, N, R, S, B
T5 Mineral insulated thermocouples according to DIN EN 61515
T5/1 Thermocouple connectors, fittings
Metal sheath materials stainless steel, material no. 1.4541 steel, heat resistant (Inconel), material no. 2.4816 steel, heat resistant (Refractaire), material no. 1.4841 steel, heat resistant (CO9902), material no. 2.4663 steel, heat resistant (Nicrobell) precious metal Pt10Rh
Sheat Ø: 0,25 / 0,5 / 1,0 / 1,5 / 2,0 / 3,0 / 4,5 / 6,0 / 8,0 mm
flexible
vibration resistant
fast responding
T6 Compensation and extension cables according to DIN EN 60584-3 connecting cables for resistance thermometers
Conductor cross-sections 0,14 / 0,22 / 0,50 / 0,75 / 1,5 mm2
Insulations: PVC, for temp. -10 °C...+105 °C PUR, for temp. -40 °C...+ 90 °C silicone, for temp. -40 °C...+200 °C teflon, for max. temp. +260 °C fiberglass, for max. temp. +400 °C
CONATEX | Alsfassener Str. 56 | D-66606 St. Wendel | Tel.: +49 68 51 . 93 39-0 | Fax: +49 68 51 . 20 76 | [email protected]
Temperature Measurement
www.conatex.dePage 9/16
A
AS2)
DIN form 1
thermowell-Ø: 15 mmconnection: stop flange or threaded sleeveconnection head: type range B ill. type BUZ
BBS2)
DIN form 2G DIN form 3G
thermowell-Ø: 9 and 11 mmconnection: fitting G½Aconnection head: type range B ill. type B
BÜ
BÜS2)
thermowell-Ø: 9 and 11 mmconnection: union nut G½Aconnection head: type range B ill. type BE
BV
BVS2)
DIN form 2
thermowell-Ø: 9 and 11 mmconnection: compression fitting G½Aconnection head: type range B ill. type B
CCS2)
DIN form 2GDIN form 3G
thermowell-Ø: 11 and 14 mmconnection: screw-in spigot G1Aconnection head: type range B ill. type BUS
D
DS2)
DIN form 4
thermowell-Ø: conical 21/12,5 mm 18/9 mmconnection: for weldingconnection head: type range B ill. type B
E
thermowell-Ø:: without inset-Ø: 6 and 8 mmconnection: compression fitting G¼A, G½Aconnection head: type range B ill. type B
FFS2)
DIN form 2FDIN form 3F
thermowell-Ø: 11 mmconnection: flange C25 / HD 40 DIN 2527 connection head: type range B ill. type BUS
KJ
KJS2)
thermowell-Ø: 9 mmconnection: fitting G½Aconnection head: type range J ill. type J
Insets: 1 x Pt 100 cl. A or B, in 2, 3 or 4 conductor connection 2 x Pt 100 cl. A or B, in 2, 3 or 4 conductor connection thermocouple type L, J, K, N, ... simplex or duplex
W1 Resistance thermometers and thermocouple assemblies according to DIN 43772 with interchangeable insets
Thermowell materials: steel St 35.8 steel St 35.8, enamelled brass stainless steel, material no. 1.4571 special materials, e.g. titanium, tantalum, Hastelloy C4, teflon
Models1):
1) DIN and factory standards 2) With tapered tip, fast responding
CONATEX | Alsfassener Str. 56 | D-66606 St. Wendel | Tel.: +49 68 51 . 93 39-0 | Fax: +49 68 51 . 20 76 | [email protected]
Temperature Measurement
www.conatex.de
Measuring resistors: Pt100 cl. A or B, single or dual
Connections: 2, 3 or 4 wire connection
Temperature range: -250 °C...+850 °C
W2 Insets for resistance thermometers PT100 according to DIN 43735
Dimensions: Ø 3,0 / 3,2 / 6,0 / 8,0 / 10,0 mm
Glass measuring resistors:
Thin film measuring resistors:
W3 Temperature sensors Pt100 DIN EN 60751
Ceramic measuring resistors:
W5 Mineral insulated resistance thermometer Pt100
Special measuring resistors:
Measuring resistors: Pt100 cl. A or B, single or dual
Dimensions: Ø 1,0 / 1,5 / 1,6 / 1,9 / 2,0 / 3,0 / 6,0 / 8,0 mm
Page 10/16
flexible
vibration resistant
fast responding
CONATEX | Alsfassener Str. 56 | D-66606 St. Wendel | Tel.: +49 68 51 . 93 39-0 | Fax: +49 68 51 . 20 76 | [email protected]
Temperature Measurement
www.conatex.de
TW Special purpose thermocouples and resistance thermometers
TW1 Push-in temperature probes
TW2/1 Indoor, outdoor and duct-mounting temperature probes
TW2/2 Temperature probes with connecting cable
TW2/3 Probes with mounted connectors
TW2/4 All teflon probes for agressive mediums
TW2/5 Pipe measuring probes
TW2/6 Magnet mounted probes
TW2/7 Surface mounted probes
TW2/8 Multi point probes
TW2/9 Probes according to customers‘ specifications
TW3 Temperature probes with hand grip
Page 11/16
Competent advice Fast quotations From prototyping and sampling up to series production Short delivery times
CONATEX | Alsfassener Str. 56 | D-66606 St. Wendel | Tel.: +49 68 51 . 93 39-0 | Fax: +49 68 51 . 20 76 | [email protected]
Temperature Measurement
www.conatex.de
TM Temperature instruments
TM 1 Handheld temperature instruments
TM 2 Infrared temperature instruments portable or stationary
TM 3 Panel mounting instruments switch points, connection head displays, field displays, large displays
TM 4 Data logger
TM 5 Multifunction simulator data logging wireless data transmission
TM 6 Controllers
TM 7 Limit controllers
TM 8 Rail mount transmitters repeater power supply
TM 9 Head mount transmitters
TM 10 Display recorders
TM 11 Calibrator
Page 12/16
CONATEX | Alsfassener Str. 56 | D-66606 St. Wendel | Tel.: +49 68 51 . 93 39-0 | Fax: +49 68 51 . 20 76 | [email protected]
Temperature Measurement
www.conatex.dePage 13/16
Digital and analog measuring, control and testing equipment for different measurands
Temperature
Pressure
Humidity
Liquid analysis
Fill level
Flow
Control and testing devices for electrical quantities
CONATEX | Alsfassener Str. 56 | D-66606 St. Wendel | Tel.: +49 68 51 . 93 39-0 | Fax: +49 68 51 . 20 76 | [email protected]
Temperature Measurement
www.conatex.de
Sales Partners
ABB Automation Products GmbH Airflow Lufttechnik GmbH Dostmann Electronic GmbH Emerson Process Management GmbH &Co.OHG Endress + Hauser Messtechnik GmbH & Co.KG Fluke Deutschland GmbH GHM Messtechnik GmbH (Greisinger)
GMC-I Messtechnik GmbH Inor Transmitter GmbH JUMO GmbH & Co.KG Knick Elektronische Messgeräte GmbH & Co. LumaSense Technologies GmbH (Impac) Mettler-Toledo GmbH OMEGA Engineering GmbH PMA Prozeß- und Maschinen-Automation GmbH PR electronics GmbH Siemens AG SIKA Dr. Siebert & Kühn GmbH & Co.KG Testo AG VEGA Grieshaber KG WIKA Alexander Wiegand SE & Co.KG WTW Wissenschaftlich-Technische Werkstätten GmbH YOKOGAWA Deutschland GmbH
Please find below the listing of our most important partner companies whose products you can also cover from us:
Page 14/16
CONATEX | Alsfassener Str. 56 | D-66606 St. Wendel | Tel.: +49 68 51 . 93 39-0 | Fax: +49 68 51 . 20 76 | [email protected]
Temperature Measurement
www.conatex.de
Notes:
Page 15/16
Temperature Measurement
2018