5
Kambič d.o.o. Metliška cesta 16, SI-8333 Semič, Slovenia - EU, T: +386 (0)7 35 65 220, info©kambic.com, [email protected] www.kambic.com, www.kambicmetrology.com Maintaining superior temperature stability Data loggers and sensors calibration World class metrology performance Accelerated ageing Stress tests TEMPERATURE CHAMBER (- 90 °C …+ 90 °C) TK-64 CKULT

Technical data sheet TEMPERATURE CHAMBER - TK-64 …

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Technical data sheet TEMPERATURE CHAMBER - TK-64 …

Kambič d.o.o. Metliška cesta 16, SI-8333 Semič, Slovenia - EU,

T: +386 (0)7 35 65 220, info©kambic.com, [email protected] www.kambic.com, www.kambicmetrology.com

• Maintaining superior temperature stability

• Data loggers and sensors calibration

• World class metrology performance • Accelerated ageing

• Stress tests

TEMPERATURE CHAMBER

(- 90 °C …+ 90 °C)

TK-64 CKULT

Page 2: Technical data sheet TEMPERATURE CHAMBER - TK-64 …

Kambič d.o.o. Metliška cesta 16, SI-8333 Semič, Slovenia - EU,

T: +386 (0)7 35 65 220, info©kambic.com, [email protected] www.kambic.com, www.kambicmetrology.com

Device description:

All exterior in galvanized and powder coated

steel RAL-7035

Extensive heat insulation shield on all chamber sides and doors

Parallel sealed with soft profile silicone seal to ensure perfect

tightness

Fan for internal air circulation with speed

control

Heavy duty closing

mechanism

Access port with both end plugs

Ø50 as standard, Ø40 or Ø90 as

accessory

Fully stainless steel chamber

2 level over temp. protection

1. 5°C over set point

heating disabled

2. 10°C above max .temp

mechanical shut off

Full 4 side maintenance access to ref.

system

Heavy duty swivel wheels with brake for

simple manipulation

Height adjustable stainless steel wire shelves

(1 wire shelve included, extra as accessory, also

perforated shelves as accessory)

Touch ontroller with user friendly interface, advance settings options, RS-232, (USB communication port

as accessory)

Page 3: Technical data sheet TEMPERATURE CHAMBER - TK-64 …

Kambič d.o.o. Metliška cesta 16, SI-8333 Semič, Slovenia - EU,

T: +386 (0)7 35 65 220, info©kambic.com, [email protected] www.kambic.com, www.kambicmetrology.com

Control panel with touch display:

Controller functions:

Menu, Exit, Clear, Enter

buttons

Time and date

Parameters display

Numerical keyboard

Increase value

Parameter selection (forward/

backward)

Decrease value

Display power switch

Start temperature

control

Stop temperature

control

LCD capacitive

touch display

System process flow

diagram

Page 4: Technical data sheet TEMPERATURE CHAMBER - TK-64 …

Kambič d.o.o. Metliška cesta 16, SI-8333 Semič, Slovenia - EU,

T: +386 (0)7 35 65 220, info©kambic.com, [email protected] www.kambic.com, www.kambicmetrology.com

Technical data:

*All performance in controlled environment (Tambient = 22 °C ± 3 °C)! *Accessories might affect performance!

TK-64 CKULT

External dimensions (WxHxD) in mm

850 x 1720 x 1100

Internal dimensions (WxHxD) in mm

450 x 400 x 400

Volume (L) ~ 72 Temperature range (°C) - 90 …+ 90 Heat up rate (°C/min) EN 60068-3-5

3

Cool down rate (°C/min) EN 60068-3-5

1

Temperature display resolution (°C) 0.1 Temperature set resolution (°C) 0.1

Temperature stability (°C)

± 0,08 °C @ - 90 °C ± 0,08 °C @ - 40 °C ± 0,05 °C @ 0 °C ± 0,05 °C @ + 90 °C

Temperature uniformity (°C)

± 0,8 °C @ - 90 °C ± 0,8 °C @ - 40 °C ± 0,6 °C @ 0 °C ± 0,8°C @ + 90 °C

Temperature control PID Power supply 3x400V 50/60Hz Wattage (W) 4800

Interface RS 232

USB (accessory) Shelve 1 (max 6) Shelve capacity (kg) 20 Max capacity (kg) 60

Access port (mm) Ø 40 standard,

(Ø 50, Ø 90 as accessory) Noise (dBA) @ 1 m distance 67 Weight (kg) ̴ 280

Page 5: Technical data sheet TEMPERATURE CHAMBER - TK-64 …

Kambič d.o.o. Metliška cesta 16, SI-8333 Semič, Slovenia - EU,

T: +386 (0)7 35 65 220, info©kambic.com, [email protected] www.kambic.com, www.kambicmetrology.com

Ordering information and accessories:

Description Part no.

Temperature chamber TK-64 CKULT 2728 Shelve wire TK-64 CKULT 2998 Shelve perforated TK-64 CKULT 2999 Access Port w. Plug Ø 40 mm right 2629 Access Port w. Plug Ø 50 mm right 608 Access Port w. Plug Ø 90 mm right 1731 USB interface 1466 TK-Tool (Software Monitoring & History) 1663 Password protection 1718 Evaluation report 9 points, 3 temperatures - performed by Kambic 1719 Evaluation report 9 points, 3 temperatures - Accredited 1852