40

Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

  • Upload
    others

  • View
    7

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers
Page 2: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

Table of Contents

2 Gas-Fired Water Heaters

6 Gas-Fired Low NOx Premix Water Heaters

8 Packaged Hot Water Systems

12 Mini-Pack™ Semi-Instantaneous Water Heaters

18 Packaged and Unpackaged Storage Water Heaters

26 Storage Tanks

30 High Effi ciency Condensing Boilers

34 Profi le: Return Loop Blend

35 Profi le: Double Wall Tube Bundles

36 Warranties & Legal Disclaimers

Series

Series

FOR INSTITUTIONAL • COMMERCIAL • INDUSTRIAL APPLICATION

Page 3: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

Ajax Boiler Inc. designs and manufactures a comprehensive line of boiler and commercial water heating

products. With over eight decades of experience, the company offers high quality, heavy duty products with

reputations for reliability, serviceability, and cost effective operation.

The administrative offi ces and manufacturing facility of Ajax Boiler Inc. are located in Santa Ana, California.

All products are designed and engineered by our in-house engineering department whose expertise combine

the disciplines of combustion and heat transfer technology, pressure vessel design, control and systems

engineering, and computer aided design. Our on-site R&D facility has the capacity to test fi re boilers up to

21,000,000 BTU/hour under load conditions with calibrated test equipment that meet all UL certifi cation testing

requirements. Product lines are distributed by more than 70 sales representatives located throughout the United

States and Canada.

Ajax Series (Space Heating and Process Steam & Hot Water) • Inclined water tube boilers• High & low pressure steam boilers• Unfi red steam boilers• Heat exchangers• Tanks (Flash, Expansion, Blow Down, and Condensate Return Feedwater)

Ace Series (Plumbing and Domestic Hot Water) • Mini-Pack semi-instantaneous, indirect water heaters• Gas-fi red conical copper fi n water heaters• Indirect storage water heaters• Tanks (Storage)

Atlas Series• High-effi ciency, condensing boilers and water heaters

One Company... Three Great Brands

Factory Assembly Line - Santa Ana, CaliforniaAce Series Water Heaters (Model B15)

Page 4: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com

GAS-FIRED COPPER FINWATER HEATERSIndoor / Outdoor SystemsLow Temperature Water and Hydronic Heating BoilersLow NOx Emission - SCAQMD Tested

Features• Proven, energy effi cient design• Indoor and outdoor construction• U.L. Listed for natural gas or propane• Conical copper fi n coil• Simple maintenance• Completely delimeable heat exchanger• Small foot print

Standard EquipmentBoiler• Single fl ow cone coil design with complete water section, including heat exchanger with cast bronze manifolds• Heat exchanger coiled from high profile finned copper tubing• Non-ferrous construction with no gasketed joints• ASME Section IV, stamped for 160 psig maximum allowable working pressure (MAWP)• Stainless steel combustion chamber• Spun aluminum top cap and 1" ceramic fiberglass insulation inside aluminized steel casing with 2" thick outer insulation; additional 22 gauge mirror finish stainless steel jacket for outdoor models• Boiler legs and bolt down lugs

Gas Burner• Cast iron ported burner with integral venturi tube and orifice for use with natural gas

Controls & Trim• Control power 120V/60Hz single-phase electronic intermittent pilot module with electic ignition• Combination dual-automatic valve/regulator/gas-cock with leakage test cock• Operating control• High limit temperature control with manual reset• Water flow switch• Pressure relief valve set at 125 psig• Temperature-pressure gauge• On-off firing mode• 24V control circuit transformer• CSD-1 control system

Indoor & Outdoor Water HeatersThe ACE Series water heaters perform dependably and quietly, providing commercial, institutional, and industrial buildings with potable hot water. The even fl ow copper fi n coils are designed to be energy effi cient throughout the life of the unit.

2

Ace Series Indoor Water HeatersFactory Assembly Line

E.T.L. Listed

E.T.L. Canadian Listed(Gas & LPG Only)

C

A.S.M.E.

LW

Page 5: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

Photo may vary from actual model

Optional EquipmentBoiler• Propane burner

Controls & Trim• Pressure relief valve set at 30, 45, or 75 psig• System “D” electronic primary safety control with interrupted pilot• Bronze circulating pump• Stack sensor/pump delay• Deliming kit

Valve Packages• Low Temperature Systems, with following components: • For inlet water temperature below 140ºF • Components: • Isolation ball valve • Blend globe valve • Check valve • Circulator • Deliming flanges • Temperature gauges • Brass header • Copper piping• Hydronic Systems: • For use in hydronic applications with low temperature rises. • Components: • Isolation Ball Valve • Blend globe valve • Check valve • Temperature gauges • Brass Header • Pump option

Tank / Heater Packages• Available with ACE Series Storage Tanks pre-piped to one or more heaters, floor- or skid-mounted, insulated and jacketed.

Indoor Gas Fired Water HeatersPhotos may vary from actual model

3

Series

Page 6: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com

Flow Switch

A

Pressure Relief ValvePress. & Temp. Gauge

BCD

E Gas Inlet

DRAFTHOOD

Flow SwitchDeliming Flanges,Inlet and OutletA

PressureRelief Valve

Temp. & Press.Gauge

BC

D

H

G

F

E

MODEL

ABOILER

DIA.

BBOILERHEIGHT

COUTLET

LOC.

DINLETLOC.

EGASPIPESIZE

FPIPELOC.

GVENTDIA.

HO.A.

HEIGHT

CIRC.PUMPSIZE1

B2G 18 36 33 24 3/4 8 6 581/4 1B3G 20 38 34 24 3/4 8 8 621/2 1B4G 24 38 34 24 3/4 9 10 681/4 1B5G 24 42 38 24 1 9 10 721/4 1B7G 28 46 39 25 1 11 12 771/4 1B8G 28 46 39 25 11/4 16 12 771/4 1B11G 32 50 43 25 11/4 16 14 851/2 1B13G 35 52 45 25 11/4 16 16 913/4 11/2B15G 35 54 48 25 11/4 16 16 933/4 11/2

1 Optional circulation pump. Higher head pump must be used to compensate for roof top piping losses.

Flow Swich standard on all models. Heater inlet and outlet connections are 1.5" NPT.

MODEL

ABOILER

DIA.

BBOILERHEIGHT

COUTLET

LOC.

DINLETLOC.

EGAS PIPESIZE

CIRC.PUMPSIZE1

B2EO 18 46 381/2 30 3/4 1B3EO 20 50 411/2 32 3/4 1B4EO 24 50 411/2 32 3/4 1B5EO 24 54 451/2 32 1 1B7EO 28 561/2 43 29 1 1B8EO 28 561/2 43 29 11/4 1B11EO 32 621/2 49 31 11/4 1B13EO 35 651/2 52 32 11/4 11/2B15EO 35 671/2 54 32 11/4 11/2

1 Optional circulation pump. Higher head pump must be used to compensate for roof top piping losses.

Flow Swich standard on all models. Heater inlet and outlet connections are 1.5" NPT.

MODEL1INPUT(BTU/HR)

OUTPUT(BTU/HR)2 H.P.

STANDARD OPERATINGDATA G.P.H. OUTPUT INDOOR

WEIGHT (LBS.)

OUTDOOR WEIGHT

(LBS.)G.P.M. HD. FT. DEGREERISE

20ºFRISE

40ºFRISE

60ºFRISE

80ºFRISE

100ºFRISE

B2_ 200,000 160,000 4.8 18.7 5 18.6 960 480 320 240 192 225 300B3_ 300,000 240,000 7.0 18.7 6 27.9 1,140 720 480 360 288 250 325B4_ 420,000 336,000 10.0 18.7 7.5 39.0 2,016 1,008 672 504 403 275 350B5_ 500,000 400,000 12.0 18.7 12 46.5 2,400 1,200 800 600 480 300 400B7_ 700,000 560,000 17.0 38.3 8.3 31.9 3,360 1,680 1,120 840 672 450 500B8_ 800,000 640,000 19.0 38.3 8.3 36.4 3,840 1,920 1,280 960 768 450 500B11_ 1,100,000 880,000 26.0 38.3 13.5 50.1 5,280 2,640 1,760 1,320 1,056 525 600B13_ 1,300,000 1,040,000 31.0 38.3 23 59.2 6,240 3,120 2,080 1,560 1,248 700 775B15_ 1,500,000 1,200,000 36.0 38.3 29.5 68.3 7,200 3,600 2,400 1,800 1,440 750 825

1 Replace the “_” in the model number with “G” for indoor and “EO” for outdoor.2 Boiler recovery rate @ 80% effi ciency based on Mfg. Lab. Test.ASME maximum allowable working pressure @ 160psi. All Models U.L. ListedG.P.H. Output based on circulation with storage tank.

Specifi cations

Dimensions - Indoor Water Heating Boilers

Dimensions - Outdoor Water Heating Boilers

Indoor & Outdoor Water Heaters

Indoor & Outdoor Gas Fired Water Heating Boilers

4

E.T.L. Listed

E.T.L. Canadian Listed(Gas & LPG Only)

C

A.S.M.E.

LW

1.5" NPT

1.5" NPT

Page 7: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

1 Optional circulation pump. Higher head pump must be used to compensate for roof top piping losses.Flow Swich standard on all models. Heater inlet and outlet connections are 1.5" NPT.

Indoor Low Temperature Water / Hydronic Heating Boilers

MODELINPUT(BTU/HR)

OUTPUT(BTU/HR)1 B.H.P.

STANDARD OPERATINGDATA G.P.H. OUTPUT INDOOR

WEIGHT (LBS.)G.P.M. HD. FT. DEGREE

RISE5ºF

RISE10ºFRISE

20ºFRISE

30ºFRISE

40ºFRISE

B2GL 200,000 160,000 4.8 18.7 5 18.6 3,840 1,920 9,60 640 480 325B3GL 300,000 240,000 7.0 18.7 6 27.9 5,760 2,880 1,440 960 720 350B4GL 420,000 336,000 10.0 18.7 7.5 39.0 8,064 4,032 2,016 1,344 1,008 375B5GL 500,000 400,000 12.0 18.7 12 46.5 9,600 4,800 2,400 1,600 1,200 400B7GL 700,000 560,000 17.0 38.3 8.3 31.9 13,440 6,720 3,360 2,240 1,680 550B8GL 800,000 640,000 19.0 38.3 8.3 36.4 15,360 7,680 3,840 2,560 1,920 550B11GL 1,100,000 880,000 26.0 38.3 13.5 50.1 21,120 10,560 5,280 3,520 2,640 625B13GL 1,300,000 1,040,000 31.0 38.3 23 59.2 24,960 12,480 6,240 4,160 3,120 800B15GL 1,500,000 1,200,000 36.0 38.3 29.5 68.3 28,800 14,400 7,200 4,800 3,600 850

Boiler recovery rate @ 80% effi ciency based on Mfg. Lab. Test.ASME maximum allowable working pressure @ 160psi. All Models U.L. Listed

Specifi cations

DRAFTHOOD

DRAFTHOOD

Flow Switch

Deliming Flanges,Inlet and Outlet

A

PressureRelief Valve

Press. & Temp. Gauge

AquastatGlobeValve

SwingValve

Operating ControlTemp. Probe

Drafthood

Pump

H

BC

D

Vent Dia.

F

E Gas Inlet

BarometricDamper

Ball Valve

MODEL

ABOILER

DIA.

BBOILERHEIGHT

COUTLET

LOC.

DINLETLOC.

EGAS PIPESIZE

FPIPE

LENGTH

GVENTDIA.

HO.A.

HEIGHT

CIRC.PUMPSIZE1

B2GL 18 36 33 24 3/4 8 6 581/4 1B3GL 20 38 34 24 3/4 8 8 621/2 1B4GL 24 38 34 24 3/4 9 10 681/4 1B5GL 24 42 38 24 1 9 10 721/4 1B7GL 28 46 39 25 1 11 12 771/4 1B8GL 28 46 39 25 11/4 16 12 771/4 1B11GL 32 50 43 25 11/4 16 14 851/2 1B13GL 35 52 45 25 11/4 16 16 913/4 11/2B15GL 35 54 48 25 11/4 16 16 933/4 11/2

5

Dimensions

E.T.L. Listed

E.T.L. Canadian Listed(Gas & LPG Only)

C

A.S.M.E.

LW

1.5" NPT

Series

Page 8: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com

GAS-FIRED COPPER FINWATER HEATERSLow NOx PremixSCAQMD Rule 1146.2 Certifi ed

Features• Proven, energy effi cient design• E.T.L. (U.L. & CSA) Listed for natural gas• Conical copper fin coil• Compact - small footprint• Indoor and outdoor construction• Simple maintenance• Completely assembled and wired• ASME Code Section IV constructed and stamped• Less than 20ppm NOx• SCAQMD Rule 1146.2 certified

Standard EquipmentBoiler• Single fl ow cone coil design with complete water section, including heat exchanger with cast bronze manifolds• Heat exchanger coiled from high profile finned copper tubing• Non-ferrous construction with gasketed joints• ASME Section IV, stamped for 160 psig Maximum Allowable Working Pressure (MAWP)• Stainless steel combustion chamber• Spun aluminum top cap and 1" ceramic fiberglass insulation with 2" thick outer insulation• 22 gauge mirror finish stainless steel jacket wrapper• Boiler legs with bolt down lugs

Gas Burner• ACE Series premix burner for natural gas

Controls & Trim• Control power 120V/60Hz single-phase• Hot surface ignition module with remote flame rod• Combination dual-automatic valve/regulator/gas-cock with leakage test cock• Operating control• High limit temperature control with manual reset• Water flow switch• Pressure relief valve set at 125 psig• Temperature-pressure gauge• On-off firing mode• 24V control circuit transformer• Barometric divertor• CSD-1 control system

Optional EquipmentControls & Trim• Pressure relief valve set at 30, 45, or 75 psig• System “D” electronic primary safety control with interrupted pilot• FM (Factory Mutual)• IRI (Industrial Risk Insurers)• Bronze circulating pump• Stack sensor/pump delay• Deliming kit

Model BPGThe ACE Series water heaters perform dependably and quietly, providing commercial, institutional, and industrial buildings with potable hot water. The even fl ow copper fi n coils are designed to be energy effi cient throughout the life of the unit.

6

Page 9: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

Tank / Heater Packages• Available with ACE Series Storage Tanks pre-piped to one or more heaters, floor- or skid-mounted, insulated and jacketed.

MODEL

ABOILER

DIA.

BBOILERHEIGHT

COUTLET

LOC.

DINLETLOC.

EGAS PIPESIZE

FPIPELOC.

GVENTDIA.

HDAMPERCENTER

LINE

ICONTROLSPROJECTN

CIRC.PUMPSIZE1

BP5G 24 42 38 24 1 9 10 11 30 1BP7G 28 46 39 25 1 11 12 12 32 1BP8G 28 46 39 25 11/4 16 12 12 32 1BP11G 32 50 43 25 11/4 16 14 13 36 1BP13G 35 52 45 25 11/4 16 16 13 36 11/2BP15G 35 54 48 25 11/4 16 16 14 36 11/2

1 Optional circulation pump. Higher head pump must be used to compensate for roof top piping losses.Heater inlet and outlet connections are 1.5" NPT.

MODELINPUT(BTU/HR)

OUTPUT(BTU/HR) H.P.

STANDARD OPERATINGDATA G.P.H. OUTPUT INDOOR

WEIGHT (LBS.)G.P.M. HD. FT. DEGREE

RISE20ºFRISE

40ºFRISE

60ºFRISE

80ºFRISE

100ºFRISE

BP5G 500,000 400,000 12 18.7 12 46.5 2,400 1,200 800 600 480 300BP7G 700,000 560,000 17 38.3 8.3 31.9 3,360 1,680 1,120 840 672 450BP8G 800,000 640,000 19 38.3 8.3 36.4 3,840 1,920 1,280 960 768 450BP11G 1,100,000 880,000 26 38.3 13.5 50.1 5,280 2,640 1,760 1,320 1,056 525BP13G 1,300,000 1,040,000 31 38.3 23 59.2 6,240 3,120 2,080 1,560 1,248 700BP15G 1,500,000 1,200,000 36 38.3 29.5 68.3 7,200 3,600 2,400 1,800 1,440 750

Photo may vary from actual model

Specifi cations

Dimensions

7

B

Flow Switch

High and Low Gas Pressure Switch

Pressure Relief Valve

Blower

Barometric Damper

Temperature & Pressure

Gauge

C

D

6"

30º 45º

FE

Ø A

Ø GI

H

E.T.L. Listed

E.T.L. Canadian Listed(Gas & LPG Only)

C

A.S.M.E.

LW

1.5" NPT

Series

Page 10: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com

Features• Sized for continuous and peak load requirements• Compactly sized, minimum floor space required• Low maintenance, easy to install• All controls, electrical, gas and water connections including the electronic ignition system are located on the front for ease of operation and service

Standard EquipmentGas-fired Copper Fin Coil Water Heaters• U.L. Listed for Natural Gas or Propane• Coil built to ASME code• Hi-Fin copper coil• Electronic ignition standard on all units• Flow switch• CSD-1 control system• Temperature-pressure gauges and relief valves on both heater(s) and tank• Mirror finish stainless steel jacketing (See Water Heater Section for more details)

Storage Tanks• Tank built to ASME code• Glass-lined model SW storage tanks (125 PSIG)• Standard selection of linings, 160ºF maximum temperature (See Storage Tank Section for more details)

Packages• All copper and bronze piping with two bronze water valves per package, and two deliming flange cut-offs per heater• Complete wiring of heater(s), controls and pumps• Bronze circulating pump• Base mounting of heaters on steel skid available (2 heaters or more)

Optional EquipmentPackages• Stack sensor / pump delay• Lead / Lag controls• FM and IRI insurance codes• Operating aquastat on tank• Base mounting to include tank and heater(s)• Jacketed and Insulated tank

GAS-FIRED COPPER FINWATER HEATERSPackaged Hot Water Systems

Packaged Hot Water SystemsThe ACE Series packaged hot water systems offer pre-piped copper fi n heaters with storage tanks to meet continuous load demands with trouble-free installation. They perform dependably and quietly, providing commercial, institutional, and industrial buildings with potable hot water. The even fl ow copper fi n coils are designed to be energy effi cient.

8

P 2Packaged Model Number:

Tank Size (in Gallons)Heater Size (B2G, B3G, etc.)# of Heaters: - = 1 Heater 2 = 2 Heaters 3 = 3 HeatersPackaged Water Heater

4 2 5GB 2

Page 11: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

Packaged Hot Water SystemsAce Series packaged hot water systems are engineered to meet continuous load demands. Continuous output is the rated output of the heater. Peak load output is the rated output of the heater plus drawing upon the storage tank reserve capacity. Shorter peak load capacities, at higher output rates and longer peak loads at lower rates, can be handled by the Ace Package Hot Water Systems. In addition to peak load capacities the Ace Systems will handle overloads with a proportional decrease in output water temperature; for example, a 20 percent overload would result in a 20 percent decrease in the rated 100ºF rise temperature or an 80ºF rise temperature, etc. Apartments and motels experience two and three hour peak loads in the morning and evenings; school and dormitory peak loads occur during shower hours; restaurant and hotels peak load are during meal and clean-up times; etc. Peak load requirements are normally the most significant selection criteria.

The Ace Series packaged hot water system is an automatic circulating type heater with a storage tank. The cold make up water enters the storage tank and mixes with hot water in the tank to raise the temperature of the water entering the heater to eliminate condensation in the heater. Return loop warm water is brought in at the suction side of the circulating pump to boost the blended water temperature entering the heater to 140ºF and reduces the possibility of condensation. If the peak load fluctuations are not too large, a small storage tank may be used. Or the volume of water in the building hot water piping may be large enough to provide the blending and recirculation requirement.

A larger storage tank should be used when very high short duration peak load conditions occur.

Automatic recirculation and blending are required to obtain the desired “gallons per hour output” at the needed temperature “rise.” The illustration shows the heater/boilers recirculating water and the blending with both make up and return water.

Refer to individual package product section for the recovery rate in the gallons per hour for a range of temperature rise for each heater/boiler model size.

By setting the operating aquastat for the desired output water temperature the heater/boiler will stay on until the temperature setting is reached. The heater/boiler standard output rating is 40ºF to 140ºF temperature “rise.” The equivalent water heating output for each of the temperature rises can be provided by the heater/boiler based upon the make up water and/or return water input temperature and the output aquastat temperature setting.

Photo may vary from actual model

9

Hot Water Out

Hot Water

Pump

ColdWater

Return WarmWater Line

Series

Page 12: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com

Relief Valve Hot Out 2"

Anode FTG

Tridicator

Tank2

Cold In

Tank Drain

CirculatedWaterReturn

PumpOptional Skid Assembly

Drain Cock & Deliming Flange

Operating Aquastat

Hi-Limit Aquastat

Deliming Flange

Electric ControlPanel

Heater1

Relief Valve

Vent Dia.FlowSwitch

Tridicator

Drafthood

D

C

BH

A

J

6"

PipeLegs

K

PACKAGEMODEL #

GPH100ºFRISE

HEATER1

MODEL #

BTUOUTPUTX1000

STORAGE2

TANKMODEL #

PUMP3

SIZE

A

HEATERDIA.

B

HEATERHEIGHT

C

WATEROUTLET

LOC.

D

WATERINLETLOC.

E

GASPIPESIZE

H

O.A.L.

J

O.A.H.

K

VENTDIA.

P_2-117 192 B2G 160 SW2404 1 18" 37" 32.5" 24 3/4 581/8 711/2 6P_3-117 288 B3G 240 SW2404 1 20" 38" 33.5" 24 3/4 621/8 831/2 8P_4-140 403 B4G 336 SW2405 1 24" 38" 33.5" 24 3/4 681/8 77 10P_5-190 480 B5G 400 SW3004 1 24" 42" 37.5" 24 1 721/8 89 10P_7-190 672 B7G 560 SW3004 1 28" 45.5" 39" 25 1 771/4 901/2 12P_8-325 768 B8G 640 SW3605 1 28" 45.5" 39" 25 11/4 771/4 1021/2 12

P_11-325 1056 B11G 880 SW3605 1 32" 49.5" 43" 25 11/4 851/2 1021/2 14P_13-325 1248 B13G 1040 SW3605 1.5 35" 51.5" 45" 25 11/4 915/8 1141/2 16P_15-375 1440 B15G 1200 SW3606 1.5 35" 53.5" 47" 25 11/4 935/8 1261/2 16

All dimensions are in inches.All packages come with ASME water pressure relief valve 125 psig, pressure and temperature gauge.

Packaged Hot Water System Listed by the E.T.L. as - Automatic Circulating Tank Type water heater, natural gas. Slightly lower ratings using propane gas. Also, approved as hot water boilers, Model B2G through B15G, for operation up to 240ºF. All Ace Series heaters and boilers are built in accordance and are stamped with the ASME codes.

CERTIFICATION

All Ace Series water heaters carry 3 year warranty on coil and 1 year on controls. Owner warranty terms and registration shipped with each heater.

LIMITED WARRANTY

Packaged Hot Water Systems

Commercial Volume Water Heater Packages

ForApartments • Motels • Hotels • School • Dormitories • Fraternities

Sororities • Convalescent and Rest Homes • Hospitals • Clinics • Sanitariums

E.T.L. Listed

E.T.L. Canadian Listed(Gas & LPG Only)

C

A.S.M.E.

LW

10

Page 13: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

Hot Water Out

Hot Water

Pump

ColdWater

Return WarmWater Line

PACKAGEMODEL

NUMBER

BTUINPUT

NATURALGAS

GPH OUTPUT 100ºF (40º - 140ºF)APTS# OF

UNITS

MOTELS# OF

BATHS

MOTELSTOURISTS

# OFBATHS

HOSPITALS# OFBEDS

FRATERNITYHOUSES

# OFOCCUPANTS

DIMENSIONS*W" x OAL x OAH

SHIPPINGWEIGHT(LBS.)

CONTIN-OUS

PEAK LOAD1 HOUR 2 HOUR 3 HOUR

P-2-117 200,000 192 282 236 220 15 15 17 17 13 26" x 57" x 72" 400#P-3-117 300,000 288 382 336 320 25 25 28 28 20 26" x 58" x 72" 435#P-4-140 420,000 403 512 456 437 40 35 40 43 33 26" x 62" x 84" 490#P-5-190 500,000 480 632 556 530 50 45 50 55 40 26" x 68" x 77" 635#P-7-190 700,000 672 824 748 723 68 52 60 68 52 30" x 71" x 77" 705#P-8-190 800,000 768 920 844 818 79 63 68 79 59 30" x 71" x 77" 755#P-8-325 800,000 768 1028 898 855 105 78 84 89 68 30" x 77" x 91" 810#

P-11-325 1,100,000 1056 1236 1146 1116 155 93 103 108 88 34" x 76" x 89" 915#P-13-325 1,300,000 1248 1508 1378 1335 204 112 122 128 102 37" x 85.5" x 91" 1090#P-15-375 1,500,000 1440 1744 1592 1541 250 150 165 170 120 37" x 85.5 x 103" 1190#

SING

LE H

EATE

R

P2-2-117 1,600,000 1540 1876 1706 1646 314 188 209 220 173 40" x 112" x 115" 1580#P2-3-117 2,200,000 2110 2492 2302 2239 362 222 243 258 196 44" x 119" x 127" 1750#P2-4-140 2,600,000 2500 2920 3344 2637 408 255 281 306 235 48" x 131.5" x 110" 2060#P2-5-190 3,000,000 2880 3440 3160 3067 550 320 350 400 290 48" x 137.5" x 111" 2210#P3-7-190 3,900,000 3750 4380 4062 3956 612 408 449 460 358 48" x 177.5" x 123" 2830#P3-8-190 4,500,000 4320 5120 4720 4587 725 435 485 550 400 48" x 183.5" x 125" 3050#M

ULTI

PLE

HEAT

ER

Commercial Volume Water Heater Packages

ForApartments • Motels • Hotels • School • Dormitories • Fraternities

Sororities • Convalescent and Rest Homes • Hospitals • Clinics • Sanitariums

* Allow additional 6 inches between vertical tank and heater for piping and pumps and 6" above vertical tank for piping. Allow additional 12" in front of package units for piping. Prices are for vertical mounted tanks only. Add approximately from 8" to 12" to increase overall height.

Sizing recommendations are for maximum demands experienced under standard conditions - normal installation. Sizing is based upon 3 GPM showers (one per unit), 40ºF inlet to 140ºF outlet water, a hot water return line (3 to 5 GPM flow), no dishwashers and no automatic washers.

The following correction factors should be applied to the number of units, occupants, people, or beds to adjust the requirement before selecting per the above table.

For Multiplier 2 bath units 1.3 5 GPM shower heads 1.4 up to 75 units 1.3 for 100 or more units 50ºF Inlet Water 0.9 60ºF Inlet Water 0.8 Altitude 1.04 for each 1000 ft. above sea level

Dishwasher - Add approximately 10 to 12 GPH heater recovery for each dishwasher.

Automatic washer - Add 40 to 50 GPH heater recovery for each standard size washer. Note: Some standard make washers take up to 60 GPH.

For 180ºF sanitizing water for dishwasher or laundry using a cement lined tank, increase GPH addition by 1.3 multiplier and provide for mixing valve.

Heater recovery rated @ 80% efficiency base on manufacturing lab. test. Ace Series heater working pressure 160#

Altitude: Derate heater output by 4% for each 1000 ft. above sea level.

P 2Packaged Model Number:

Tank Size (in Gallons)Heater Size (B2G, B3G, etc.)# of Heaters: - = 1 Heater 2 = 2 Heaters 3 = 3 HeatersPackaged Water Heater

4 2 5GB 2

11

Series

Page 14: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com

MINI-PACK™ WATER HEATERSCompact & Semi-InstantaneousSingle-Wall or Double-Wall Tube Bundles

Features• Close temperature controls with ±4ºF at heater hot water outlet under normal operating conditions• Solid rust-free stainless steel construction on the entire domestic water side and standard stainless steel jacket• Compactly sized requiring minimum space for installation, with vertical or horizontal heater choice• Tube bundle readily accessible without moving, shell or foundation for all single wall models; recommended horizontal mounting of double wall due to coil length• Standard sizes cover hot water output from 1 to 769 GPM simplifying size selection and layout• Quality components for high performance

Standard EquipmentShell• ASME Section VIII Div I vessel• National Board registered• 150 psig design working pressure• Vertical or horizontal model with solid 316L stainless steel construction and 304L stainless steel fittings

Tube Bundle• 150 psig design working pressure• SB-75 seamless copper U-tube• Single wall tubing• 304 stainless steel tube sheet

Support• Steel support stand

Controls• Electric, Pneumatic and Pilot operated control valve for steam Electric and Pneumatic control valve for water• 150 psig ASME pressure relief valve• High limit aquastat• Safety solenoid valve• NEMA 1 control panel• Temperature gauge• 1/6 HP recirculator pump• Condensate orifice trap and steam strainer for steam models

Optional EquipmentShell & Tube Bundle• Horizontal model available• Double wall copper or cupro-nickel (90/10) tubing• Single wall cupro-nickel (90/10) or 316L stainless steel tubing• 250 psig shell and tube design working pressure• 400 psig tube design working pressure, for HTW

Support• Steel horizontal single rack for 2 Mini-Pack™

Mini-Pack™The Ace Series Mini-Pack™ semi-instananeous water heater is dependable and quiet, and provides commercial and institutional buildings with potable hot water. Close temperature controls, outstanding thermal effi ciency, high quality ASME coded construction, and minimum fl oor space requirements make the Mini-Pack™ one of our best selling products.

12

Page 15: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

Controls• Electric, pneumatic water valves or pilot operated for steam• Double safety solenoid dump valve• Dual valves setup: 1/2 and 2/3 pneumatic control• Building automation relays• T&P steam trap• Alarm bell with silencer switch

Operating Controls• Digital panel• Remote SetPoint panel• Local monitoring panel• Building Automation panel• Ajax Communication Gateway

The Mini-Pack™ temperature control system keeps the heated water within four degrees of the selected temperature. This close control is accomplished by placing the temperature control element directly in the constant fl ow path of the water leaving the heating surface making so-called “anticipator” devices unnecessary. After the water passes over the control element it enters a tempering chamber between the heating surface and the water outlet.

Another essential part of the temperature control system is the integral circulator. This small pump (1/6 HP) constantly recirculates a portion of the heated water to the cold water inlet making “the total volume of the heater” a tempering chamber. Also eliminates any overheated water pockets caused by control valve lag when hot water demand is suddenly reduced. The pump can also be used to provide recirculation of the water from the fi xtures through a tee fi tting that is provided with the package. Where the hot water return system requires greater recirculation the integral pump size can be pre-selected to provide the duty.

The Mini-Pack™ features total rust free construction with austenitic stainless steel and copper for all domestic water contact surfaces, providing high quality, low maintenance and an extremely cost-effective domestic water heating package. Non-metallic PTFE baffl es are used to prevent tube damage.

The vertical Mini-Pack™ semi-instantaneous heater saves fl oor space, is simple to install and very easy to service and maintain. The vertical unit also provides complete drainage of condensate. Universal mounting brackets allow the Mini-Pack™ to be mounted in the horizontal position.

Photo may vary from actual model

Horizontal Pneumatic Mini-Pack™

Optional horizontal single modelstand or dual model rack.

(as shown)

Photo may vary from actual model

13

A.S.M.E.

Series

Page 16: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com

MODELA B C D E G J K L1 SHIPPING

WEIGHT(LBS.)

WATER VOL. IN

SHELL (GAL.)SI-V-4-SW-xx 83 40 30 251/4 301/4 12 9 3/4 2 350 2.1SI-V-5-SW-xx 693/4 333/4 23 19 24 12 10 1 21/2 400 2.5SI-V-6-SW-xx 86 42 313/4 261/2 311/2 12 101/2 1 21/2 500 4.5SI-V-8-SW-xx 751/2 361/2 243/4 191/2 251/4 12 111/2 11/2 3 600 6.8SI-V-8L-SW-xx 881/2 431/2 303/4 261/2 321/4 12 131/2 2 3 650 7.7SI-V-10-SW-xx 791/2 383/4 25 20 26 18 131/2 2 4 F 900 10.6SI-V-10L-SW-xx 921/2 453/4 31 27 33 18 131/2 2 4 F 950 11.9SI-V-12-SW-xx 831/2 413/4 241/2 153/4 253/4 18 141/2 21/2 4 F 1,125 15.9SI-V-12L-SW-xx 1071/2 533/4 361/2 273/4 373/4 18 141/2 21/2 4 F 1,175 19.2SI-V-14-SW-xx 981/2 483/4 301/2 181/2 301/2 18 161/4 3 5 F 1,700 22.0SI-V-14L-SW-xx 1281/2 633/4 451/2 331/2 451/2 18 161/4 3 5 F 1,800 27.5SI-V-16-SW-xx 122 603/4 401/2 261/2 40 18 18 3 6 F 2,200 34.2SI-V-16L-SW-xx 150 743/4 541/2 401/2 54 18 18 3 6 F 2,350 47.0

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

VERTICALSINGLE-WALL

STEAM TO WATER

Mini-Pack™ Water Heaters

‘L’HOT WATER

OUTLET

INLETSTEAM

A

C

B

D

J

G

E

1" FPT

HOT WATEREVACUATIONTO SAFE AREA

K

Dimensions - Vertical Single-Wall Steam-to-Water

A

C

B

‘L’HOT WATEROULET

H

3/4" BOLT HOLE

D

E

J

G

‘K’ FPTCONDENSATE

INLETSTEAM

MODELA B C D E G H J K L1 SHIPPING

WEIGHT(LBS.)

WATERVOL. IN

SHELL (GAL.)SI-H-4-SW-xx 561/4 131/4 30 31/2 131/2 71/2 401/2 91/4 3/4 2 300 2.1SI-H-5-SW-xx 491/4 131/4 23 31/2 143/4 83/4 331/2 10 1 21/2 350 2.5SI-H-6-SW-xx 573/4 133/4 313/4 31/2 151/4 93/4 413/4 101/2 1 21/2 450 4.5SI-H-8-SW-xx 541/4 151/4 243/4 4 181/4 113/4 363/4 111/2 11/2 3 550 6.8SI-H-8L-SW-xx 601/4 151/4 303/4 4 181/4 113/4 423/4 111/2 11/2 3 600 7.7SI-H-10-SW-xx 571/2 163/4 25 41/4 22 141/2 371/2 131/2 2 4 F 850 10.6SI-H-10L-SW-xx 631/2 163/4 31 41/2 22 141/2 431/2 131/2 2 4 F 900 11.9SI-H-12-SW-xx 641/2 23 241/2 7 261/2 161/2 383/4 141/2 21/2 4 F 1,075 15.9SI-H-12L-SW-xx 761/2 23 361/2 7 261/2 161/2 503/4 141/2 21/2 4 F 1,125 19.2SI-H-14-SW-xx 761/4 263/4 301/2 81/2 26 181/2 461/4 151/2 3 5 F 1,650 22.0SI-H-14L-SW-xx 911/4 263/4 451/2 81/2 26 181/2 611/4 151/2 3 5 F 1,750 27.5SI-H-16-SW-xx 913/4 303/4 401/2 10 27 20 583/4 161/4 3 6 F 2,150 34.2SI-H-16L-SW-xx 1053/4 303/4 541/2 10 27 20 723/4 161/4 3 6 F 2,300 47.0

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

HORIZONTALSINGLE-WALL

STEAM TO WATER

Dimensions - Horizontal Single-Wall Steam-to-Water

14

A.S.M.E.

A.S.M.E.

L

Page 17: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

MODELA B C D E G J K L1 SHIPPING

WEIGHT(LBS.)

WATER VOL. IN

SHELL (GAL.)SI-V-5-DW-SP 981/4 271/2 55 12 163/4 12 10 1 21/2 400 4.7SI-V-6-DW-SP 102 303/4 541/2 14 191/4 12 101/2 1 21/2 500 6.9SI-V-8-DW-SP 983/4 311/2 551/4 131/4 19 12 111/2 11/2 3 600 11.8SI-V-10-DW-SP 1051/2 353/4 561/2 151/2 213/4 18 131/2 2 4 F 1,000 18.5SI-V-12-DW-SP 1101/2 391/4 55 113/4 213/4 18 141/2 21/2 4 F 1,300 26.5SI-V-14-DW-SP 122 413/4 63 93/4 213/4 18 161/4 3 5 F 1,900 34.1SI-V-16-DW-SP 1281/2 44 663/4 83/4 221/4 18 18 3 6 F 2,450 46.9

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

VERTICALDOUBLE-WALL

STEAM TO WATER

‘L’HOT WATER

OUTLET

INLETSTEAM

A

C

B

D

J

G

E

1" FPT

HOT WATEREVACUATIONTO SAFE AREA

L

K

Dimensions - Vertical Double-Wall Steam-to-Water

15

MODELA B C D E G H J K L1 SHIPPING

WEIGHT(LBS.)

WATERVOL.IN

SHELL (GAL.)SI-H-5-DW-SP 85 141/4 55 31/2 143/4 83/4 66 10 1 21/2 435 4.7SI-H-6-DW-SP 861/4 15 541/2 31/2 151/4 93/4 67 101/2 1 21/2 535 6.9SI-H-8-DW-SP 833/4 161/2 551/4 4 181/4 113/4 68 111/2 11/2 3 635 11.8SI-H-10-DW-SP 88 181/4 561/2 41/8 22 141/2 691/2 131/2 2 4 F 950 18.5SI-H-12-DW-SP 953/4 241/2 55 7 261/2 161/2 703/4 141/2 2 4 F 1,200 26.5SI-H-14-DW-SP 109 281/2 63 81/2 251/4 181/2 791/2 151/2 2 5 F 1,750 34.1SI-H-16-DW-SP 1161/2 321/2 66 10 27 20 831/2 161/4 2 6 F 2,250 46.9

HORIZONTALDOUBLE-WALL

STEAM TO WATER

A

C

B

‘L’HOT WATER

OULET

H

3/4" BOLT HOLE

D

J

G

‘K’ FPTCONDENSATE

INLETSTEAM

Dimensions - Horizontal Double-Wall Steam-to-Water

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

A.S.M.E.

INLETSTEAM

E

A.S.M.E.

Series

Page 18: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com

VERTICALSINGLE-WALL

WATER TO WATER

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

MODELA B C E G J L1 SHIPPING

WEIGHT(LBS.)

WATERVOL. IN

SHELL (GAL.)SI-V-4-SW-xx 83 40 30 301/4 12 91/4 2 300 2.1SI-V-5-SW-xx 693/4 333/4 23 24 12 10 21/2 350 2.5SI-V-6-SW-xx 86 42 313/4 311/2 12 101/2 21/2 400 4.5SI-V-8-SW-xx 751/2 361/2 243/4 251/4 12 111/2 3 500 6.8SI-V-8L-SW-xx 1141/2 561/2 433/4 321/4 12 111/2 3 550 7.7SI-V-10-SW-xx 791/2 383/4 25 271/2 18 131/2 4 F 850 10.6SI-V-10L-SW-xx 921/2 453/4 31 341/2 18 131/2 4 F 900 11.9SI-V-12-SW-xx 831/2 413/4 241/2 283/4 18 141/2 4 F 1,075 15.9SI-V-12L-SW-xx 1071/2 533/4 361/2 403/4 18 141/2 4 F 1,200 19.2SI-V-14-SW-xx 90 483/4 301/2 34 18 161/4 5 F 1,550 22.0SI-V-14L-SW-xx 1281/2 633/4 451/2 49 18 161/4 5 F 1,850 27.5SI-V-16-SW-xx 122 603/4 401/2 291/2 18 161/4 6 F 2,125 34.2SI-V-16L-SW-xx 150 783/4 541/2 521/2 18 161/4 6 F 2,350 47.0

Mini-Pack™ Water Heaters

Dimensions - Vertical Single-Wall Water-to-Water

HORIZONTALSINGLE-WALL

WATER TO WATER

E

BOILER WATEROUTLET

BOILER WATERINTLET

G

‘L’COLDWATERINLET

J

3/4" BOLT HOLE

‘L’HOT WATEROUTLET

D

B

C

A

H

E

BOILER WATEROUTLET

BOILER WATERINTLET

G

J B

C

A

HOT WATEREVACUATIONTO SAFE AREA

‘L’COLD

WATERINLET

HOT WATEROUTLET

‘L’

1" FPT

16

MODELA B C D E G H J L1 SHIPPING

WEIGHT(LBS.)

WATERVOL. IN

SHELL (GAL.)SI-H-4-SW-xx 561/4 131/4 30 31/2 131/2 241/2 401/2 91/4 2 275 2.1SI-H-5-SW-xx 491/4 131/4 23 31/2 143/4 241/2 331/2 10 21/2 300 2.5SI-H-6-SW-xx 573/4 133/4 313/4 31/2 151/4 241/2 413/4 101/2 21/2 350 4.5SI-H-8-SW-xx 541/4 151/4 243/4 4 181/4 28 363/4 111/2 3 450 6.8SI-H-8L-SW-xx 601/4 151/4 303/4 4 181/4 28 423/4 111/2 3 500 7.7SI-H-10-SW-xx 553/4 151/4 25 4 22 31 371/2 131/2 4 F 800 10.6SI-H-10L-SW-xx 613/4 151/4 31 4 22 31 431/2 131/2 4 F 850 11.9SI-H-12-SW-xx 581/2 17 241/2 4 261/2 34 383/4 141/2 4 F 1,025 15.9SI-H-12L-SW-xx 701/2 17 361/2 4 261/2 34 503/4 141/2 4 F 1,150 19.2SI-H-14-SW-xx 703/4 21 301/2 61/2 251/4 35 461/4 151/2 5 F 1,500 22.0SI-H-14L-SW-xx 853/4 21 451/2 61/2 251/4 35 611/4 151/2 5 F 1,800 27.5SI-H-16-SW-xx 841/4 23 401/2 63/4 27 36 583/4 161/4 6 F 2,075 34.2SI-H-16L-SW-xx 981/4 23 541/2 63/4 27 36 723/4 161/4 6 F 2,300 47.0

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

Dimensions - Horizontal Single-Wall Water-to-Water

A.S.M.E.

A.S.M.E.

Page 19: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

MODELA B C E G J L1 SHIPPING

WEIGHT(LBS.)

WATERVOL. IN

SHELL (GAL.)SI-V-5-DW-xx 981/2 271/2 55 163/4 12 10 21/2 425 4.7SI-V-6-DW-xx 102 303/4 541/2 191/4 12 101/2 21/2 500 6.9SI-V-8-DW-xx 983/4 311/2 551/4 19 12 111/2 3 700 11.8SI-V-10-DW-xx 1051/2 353/4 561/2 231/4 18 131/2 4 F 1,100 18.5SI-V-12-DW-xx 1101/2 391/4 55 243/4 18 141/2 4 F 1,425 26.5SI-V-14-DW-xx 122 413/4 63 251/4 18 161/4 5 F 1,975 34.1SI-V-16-DW-xx 1281/2 44 663/4 293/4 8 18 6 F 2,475 46.9

VERTICALDOUBLE-WALL

WATER TO WATER

Dimensions - Vertical Double-Wall Water-to-Water

HORIZONTALDOUBLE-WALL

WATER TO WATER

E

BOILER WATER

OUTLET

BOILER WATERINLET

G

COLDWATERINLET ‘L’

J

3/4" BOLT HOLE

‘L’ HOT WATER

OUTLETFAR SIDE

D

B

C

A

H

MODELA B C D E G H J L1 SHIPPING

WEIGHT(LBS.)

WATERVOL. IN

SHELL (GAL.)SI-H-5-DW-xx 85 141/4 55 31/2 143/4 241/2 66 10 21/2 375 4.7SI-H-6-DW-xx 861/4 15 541/2 31/2 151/4 241/2 67 101/2 21/2 450 6.9SI-H-8-DW-xx 833/4 161/2 551/4 4 181/4 28 68 111/2 3 650 11.8SI-H-10-DW-xx 861/4 161/2 561/2 4 22 31 691/2 131/2 4 F 1,050 18.5SI-H-12-DW-xx 893/4 181/2 55 4 261/2 34 703/4 141/2 4 F 1,375 26.5SI-H-14-DW-xx 1033/4 231/2 63 61/2 251/4 35 791/2 151/2 5 F 1,925 34.1SI-H-16-DW-xx 1091/2 251/2 663/4 63/4 27 36 831/2 161/4 6 F 2,425 46.9

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

Dimensions - Horizontal Double-Wall Water-to-Water

BOILER WATEROUTLET

BOILER WATERINTLET

G

J B

C

A

HOT WATER EVACUATION TO SAFE AREA

‘L’COLD

WATERINLET

‘L’HOT

WATEROUTLET

E

1"FPT

17

A.S.M.E.

A.S.M.E.

Series

Page 20: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com

PACKAGED STORAGEWATER HEATERSSingle-Wall or Double-Wall Tube Bundles

Also Available:

Unpackaged Storage Water Heaters

Features• Completely assembled storage water heaters with tube bundle or electric heating elements, automatic controls, valves, piping, circulating system, wiring, insulation and skid mounted• Provides for peak load outputs and utilizes off peak boiler capacity• Small, medium, or large storage volumes available in vertical and horizontal models• ACE Temp Control System• Tube bundle readily accessible without moving heater, shell or foundation• Quality components for high performance

Standard EquipmentTank• ASME Section VIII Div I vessel• National Board registered• 125 and 150 psig design working pressure• 12" x 16" manway on 42" diameter and larger diameter tanks; inspection openings for all others• Carbon steel fittings• Lining: Glass (160ºF), cement (180ºF), pre-krete (350ºF), unlined• Lifting straps or lugs• Drain fittings• Anodes on glass lined tanks

Tube Bundle• 150 psig design working pressure

• SB-75 seamless copper U-tube• Single wall tubing• Steel cap and tube sheet

Support• Vertical: pipe legs• Horizontal: saddles

Controls• Water-to-water: Self-operating, Electric or Pneumatic control valve (standard) Steam-to-water: Electric, Pneumatic or Pilot-operated control valve • Temperature-Pressure gauge• High limit aquastat• 150 psig ASME pressure relief valve• ACE Temp Control System, including all bronze circulating pump with copper piping and isolation valve• Steam to water model only: F&T steam trap and vacuum breaker• Panel mounted gauges

Insulation & Jacketing• 22 gauge galvanized steel jacket, backed by 11/2" of insulation• Painted with primer

Packaged Storage Water HeatersThe ACE storage water heaters are dependable and quiet. They provide peak load output and use off-peak boiler capacity. Units are available in a variety of confi gurations to meet a wide range of requirements for temperature rise and G.P.H. recovery.

18

Page 21: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

Optional EquipmentTube Bundle• Double wall copper or cupro-nickel (90/10) tubing• Single wall cupro-nickel (90/10) or 304 stainless steel tubing• Stainless steel cap and tube sheet• High temp water applications• 4 pass tube bundle design

Support• Vertical: Ring base, angle iron legs• No support / leg coupling, only for unpackaged

Controls• Pneumatic or electric control valve, with temperature controller NEMA 1 control panel and inlet strainer• Unpackaged• Double safety solenoid dump valve• Building automation relays• Alarm bell with silencer switch

Operating Controls• Digital panel• Remote SetPoint panel• Local monitoring panel• Building Automation panel• Ajax Communication Gateway

Insulation & Jacketing• Mirror finish stainless steel jacketing• 3" thick insulation

Vertical PackageStorage Water HeaterPhoto may vary from actual model

19

A.S.M.E.

Photo may vary from actual model

Series

Page 22: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com

Packaged Storage Water Heaters

VERTICALSTEAM-TO-WATERPILOT-OPERATED

HORIZONTALSTEAM-TO-WATERPILOT-OPERATED

Packaging items may extend beyond vessel dimensions. For vertical packaging, add approximately 15" to tank height for overall height and 24" diameter for depth. For horizontal packaging, size is tank diameter and overall length add approximately 15" (for base) to obtain height and 24" to overall length to allow for coil and controls. Output is based upon clean copper tube condition. Ajax recommends 25% to 75% oversizing depending upon hardness of water. Tubes should be inspected frequently and descaled as required.1Ace Temp Control System Automatic Rapid Temperature Response. The Ace Temp Control System will accurately vary the fl ow of steam of the heating coil in proportion to the variation in fl ow and temperature of the domestic water demands. Ace Temp Control System provides rapid response by locating control bulb in recirculating line thereby eliminating delays due to lengthy bleed lines. Ace Temp Control System senses blended water temperature for instant smooth opening and closing of steam control valve, also eliminates excessive cycling of steam valve that can occur when short bursts of cold water are fl ushed over an immersed sensor bulb.

20

Steam Pressure Gauge

VaccumBreaker

Control System1

with Sensors

Temp. & Press. Gauge

Lifting LugsHot Water Outlet

CirculatorPump

RecirculationLine

Condensate Out

Cold Water Inlet

Strainer

11/2" Insulation &Metal Jacketing

Anode(for glass lined tanks)

Relief Valve

STORAGE SECTION

HEATING SECTION

DrainDouble

WallSingleWall

Manhole12"x16"

(for 36" Dia. and up tank only)

Safety Solenoid

Aquastat

ControlBox

Steam In

Control Valve

Plug Valve& Piping

Coil PullArea

Manhole12"x16" (for 36" Dia.and up tank only)

Lifting Lugsor StrapsHot Water Outlet

DoubleWall

Anode(for glass lined tanks)

Steam Pressure Gauge

Control1

System withSensors

Temp. & Press. Gauge

Circulator Pump

Condensate Out

Steam In

11/2" Insulation &Metal Jacketing

Control Valve

Relief Valve

SingleWall

Cold In Drain

STORAGE SECTION

HEATING SECTION

Coil PullAreaAquastat

Strainer

Plug Valve& Piping

RecirculationLine

Control Box

VacuumBreakerSafety Solenoid

A.S.M.E.

A.S.M.E.

Page 23: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

HORIZONTALSTEAM TO WATERPNEUMATIC

Packaging items may extend beyond vessel dimensions. For vertical packaging, add approximately 15" to tank height for overall height and 24" diameter for depth. For horizontal packaging, size is tank diameter and overall length add approximately 15" (for base) to obtain height and 24" to overall lenght to allow for coil and controls. Output is based upon clean copper tube condition. Ace recommends 25% to 75% oversizing depending upon hardness of water. Tubes should be inspected frequently and descaled as required.1Ace Temp Control System Automatic Rapid Temperature Response. The Ace Temp Control System will accurately vary the fl ow of steam of the heating coil in proportion to the variation in fl ow and temperature of the domestic water demands. Ace Temp Control System provides rapid response by locating control bulb in recirculating line thereby eliminating delays due to lengthy bleed lines. Ace Temp Control System senses blended water temperature for instant smooth opening and closing of steam control valve, also eliminates excessive cycling of steam valve that can occur when short bursts of cold water are fl ushed over an immersed sensor bulb.

VERTICALSTEAM-TO-WATERPNEUMATIC

21

Anode(for glass lined tanks)

Temp. & Press. Gauge

Lifting strap or lugsHot WaterOutlet

Circulator Pump

Condensate Out Cold Water Inlet

Steam In

11/2" Insulation &Metal Jacketing

Drain

Relief Valve

To air supply

DoubleWall

SingleWall

Manhole12"x16" (for 36" Dia.and up tank only)

STORAGE SECTION

HEATING SECTIONStrainer

Plug Valve& Piping

Control Valve

AquastatSafety Solenoid

Steam Pressure Gauge

Control Box

Control1

System withSensors

RecirculationLine

Coil PullArea

Steam Pressure Gauge

Temp. & Press. Gauge

Hot Water Outlet

Circulator Pump

RecirculationLine

Cold Water Inlet

Strainers

11/2" Insulation &Metal Jacketing Anode

(for glass lined tanks)

PneumaticControl

To air supply

Relief Valve

DoubleWall

SingleWall

Safety Solenoid

Aquastat

Condensate Out

Lifting lugs

Coil PullArea

Control Valve

Control Box

Control System1

with Sensors

Drain Plug Valve& Piping

HEATING SECTION

STORAGE SECTION

A.S.M.E.

A.S.M.E.

Series

Page 24: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com

Packaged Storage Water Heaters

Packaging items may extend beyond vessel dimensions. 3-way blending valve may vary according to manufacturer’s design. Please check with factory for specifi c piping. For vertical packaging, add approximately 15" to tank height for overall height and 24" diameter for depth. For horizontal packaging, size is tank diameter and overall length add approximately 15" (for base) to obtain height and 24" to overall lenght to allow for coil and controls. Output is based upon clean copper tube condition. Ace recommends 25% to 75% oversizing depending upon hardness of water. Tubes should be inspected frequently and descaled as required.1Ace Temp Control System Automatic Rapid Temperature Response. The Ace Temp Control System will accurately vary the fl ow of steam of the heating coil in proportion to the variation in fl ow and temperature of the domestic water demands. Ace Temp Control System provides rapid response by locating control bulb in recirculating line thereby eliminating delays due to lengthy bleed lines. Ace Temp Control System senses blended water temperature for instant smooth opening and closing of steam control valve, also eliminates excessive cycling of steam valve that can occur when short bursts of cold water are fl ushed over an immersed sensor bulb.

VERTICALWATER-TO-WATERPNEUMATIC

HORIZONTALWATER-TO-WATERPNEUMATIC

22

ReliefValve

Temp. & Press. Gauge

Control Box

B.W. Temp.Gauge

In & Out

CirculatorPump

Anode(for glass lined tanks)

Pneumatic Control

Boiler WaterSupply Inlet

Safety Solenoid

Cold Water Inlet Drain

Lifting strap or lugs

Air Supply

Coil PullArea

Hot WaterOutlet

DoubleWall

SingleWall

Manhole12"x16" (for 36" Dia.and up tank only)

Control Valve

Aquastat

Plug Valve& Piping

Boiler WaterReturn

Control System1

with Sensors HEATING SECTION

STORAGE SECTION

B.W. Temp.Gauge In & Out

Control System1

with Sensors

Drain

Lifting lugs

CirculatorPump

Temp. & Press.Gauge

Recirculation Line

Boiler Water InletCold Water Inlet

Aquastat

Safety Solenoid

11/2" Insulation &Metal Jacketing

Anode(for glass lined tanks)

Control Box

To air supply

Relief Valve

Manhole12"x16" (for 36" Dia.and up tank only)

STORAGE SECTION

HEATING SECTION

DoubleWall

SingleWall

Coil PullArea

Boiler Water Return

Pneumatic Control

Control Valve

Plug Valve& PipingA.S.M.E.

A.S.M.E.

Page 25: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

Packaging items may extend beyond vessel dimensions. 3-way blending valve may vary according to manufacturer’s design. Please check with factory for specifi c piping. For vertical packaging, add approximately 15" to tank height for overall height and 24" diameter for depth. For horizontal packaging, size is tank diameter and overall length add approximately 15" (for base) to obtain height and 24" to overall lenght to allow for coil and controls. Output is based upon clean copper tube condition. Ace recommends 25% to 75% oversizing depending upon hardness of water. Tubes should be inspected frequently and descaled as required.1Ace Temp Control System Automatic Rapid Temperature Response. The Ace Temp Control System will accurately vary the fl ow of steam of the heating coil in proportion to the variation in fl ow and temperature of the domestic water demands. Ace Temp Control System provides rapid response by locating control bulb in recirculating line thereby eliminating delays due to lengthy bleed lines. Ace Temp Control System senses blended water temperature for instant smooth opening and closing of steam control valve, also eliminates excessive cycling of steam valve that can occur when short bursts of cold water are fl ushed over an immersed sensor bulb.

VERTICALWATER-TO-WATERSELF-OPERATING

HORIZONTALWATER-TO-WATERSELF-OPERATING

23

B.W. Temp.Gauge In & Out

Temp. & Press. Gauge

Lifting LugsHot Water Outlet

Circulator Pump

RecirculationLine

Boiler Water Inlet

Cold Water Inlet

Drain

Boiler WaterReturn

11/2" Insulation &Metal Jacketing

Anode(for glass lined tanks)

Relief Valve

DoubleWall

SingleWall

STORAGE SECTION

HEATING SECTION

CoilPullArea

Plug valve &piping

Manhole12"x16" (for 36" Dia.and up tank only)

Control System1

with Sensors

Control Valve

Relief ValveTemp. & Press. Gauge

B.W. Temp.Gauge In & Out

CirculatorPump

Anode(for glass lined tanks) 11/2" Insulation &

Metal Jacketing

Control Valve

Boiler WaterSupply Inlet

Lifting strap or lugs

DrainCold WaterInlet

Coil PullArea

Hot WaterOutlet

DoubleWall

SingleWall

HEATING SECTION

Manhole12"x16" (for 36" Dia.and up tank only)

STORAGE SECTION

Plug Valve& Piping

Recirculation Line

Boiler WaterReturn

A.S.M.E.

A.S.M.E.

Series

Page 26: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com

NOMINALBUNDLE

SIZE1

DIMENSION COMMONTO 2, 4, & 6 PASS 2-PASS 4-PASS 6-PASS

E* F G H JBUNDLE IN. K J

BUNDLE IN. K JBUNDLE IN. K

5 13 59/16 8 11/4 13/8 11/4 13/8 N/A N/A6 20 65/8 8 11/2 15/8 11/2 15/8 1 18 24 85/8 9 21/2 21/8 2 21/8 11/2 13/8

10 26 103/4 11 3 23/4 21/2 23/4 2 15/812 28 123/4 15 4F 31/4 3 31/4 21/2 214 30 14 17 4F 31/2 4F 31/2 3 21/416 34 16 19 5F 4 4F 4 4F 21/2

Unpackaged Storage Water HeaterHorizontal A.S.M.E. 125 or 150 psig Storage Water Heater with Standard Fittings

TANK DIAMETER (IN.)

18 24 30 36 42 48 54 60 66 72

(A) Water Conn. 11/2 11/2 2 2 2 3 3 3 3 3(B) Head Depth 6 71/2 9 101/2 12 131/2 11/2 161/2 171/2 20

Unpackaged Storage Water Heaters

Unpackaged Storage Water Heaters

24

A.S.M.E.

1 18" Dia. and larger bundles available. Consult factory. The dimensional table is also applicable for double-wall tube bundles.2 12"x16" Manway standard only on all Section VIII tanks 42" diameter and above. All others to have inspection openings as required by ASME Code.3 Refer to storage tank section.

Fitting locations to be dimensioned from head and shell joint. Tolerance ±2%.

CAP/BONNET CONFIGURATIONCAP/BONNET CONFIGURATION

2-PASS 4-PASS 6-PASS

C

C

C

CC

C

DD

DK

2-Pass bundles are furnished for all steam units. Multi-pass bundles are normally furnished for all hot water boiler units. 2-Pass bundles will be furnished if heating medium or boiler water fl ow is unknown.

* See E table below.

TANKDIA. 18 24 30 36 42 48 54 60 66 72

BUNDLESIZE E

5 5 5 8 86 6 6 10 11 11 12 12 138 7 7 9 9 13 13 14 14 15 1610 13 14 14 15 16 1712 14 15 15 16 17 1814 18 1916 19 20

Drain 11/2"

Coil Support ACold In

G

EEF

HH9"

Operating11/4" Control

3/4" Thermostat

ReliefValve

B

A Hot Out

4" 4"

STORAGE SECTION

HEATING SECTION

Manway2

Tank3 O.A.L.

Tank3 O.D.

6"

Bundle pull area

11/2" Recirc. far side

Anode openingsglass lined only

Page 27: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

Vertical A.S.M.E. 125 or 150 psig Storage Water Heater with Standard Fittings

NOMINALBUNDLE

SIZE1

DIMENSION COMMONTO 2, 4, & 6 PASS 2-PASS 4-PASS 6-PASS

E F G H JBUNDLE IN. K J

BUNDLE IN. K JBUNDLE IN. K

5 8 16 59/16 8 11/4 13/8 11/4 13/8 N/A N/A6 8 20 65/8 8 11/2 15/8 11/2 15/8 1 18 9 24 85/8 9 21/2 21/8 2 21/8 11/2 13/8

10 10 26 103/4 11 3 23/4 21/2 23/4 2 15/812 12 28 123/4 15 4F 31/4 3 31/4 21/2 214 13 30 14 17 4F 31/2 4F 31/2 3 21/416 14 34 16 19 5F 4 4F 4 4F 21/2

TANK DIAMETER (IN.)

18 24 30 36 42 48 54 60 66 72

(A) Water Conn. 11/2 11/2 2 2 2 3 3 3 3 3(B) Head Depth 6 71/2 9 101/2 12 131/2 151/2 161/2 171/2 20

G

TOP VIEW

25

A.S.M.E.

1 18" Dia. and larger bundles available. Consult factory. The dimensional table is also applicable for double-wall tube bundles.2 12"x16" Manway standard only on all Section VIII tanks 42" diameter and above. All others to have inspection openings as required by ASME Code.3 Refer to storage tank section.

Fitting locations to be dimensioned from head and shell joint. Tolerance ±2%.

CAP/BONNET CONFIGURATIONCAP/BONNET CONFIGURATION

2-PASS 4-PASS 6-PASS

C

C

C

CC

C

DD

DK

2-Pass bundles are furnished for all steam units. Multi-pass bundles are normally furnished for all hot water boiler units. 2-Pass bundles will be furnished if heating medium or boiler water fl ow is unknown.

11/2" Recir. Far Side

3/4" Thermostat

OperatingControl

STORAGE SECTION

HEATING SECTION

Anode OpeningGlass Lined Only

Coil SupportDrain

F

E

BB

A Cold In

ReliefValve

A Hot Out

G

Manway2

9"

H

Tank3 O.D.

Tank3 O.A.L.

Bundlepull area

Series

Page 28: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com

Storage TanksThe ACE storage tanks are designed and manufactured using only the highest quality ASME code certifi ed materials for all types of volume hot water requirements. A broad selection of tank linings provide extended tank life and ensures clean, safe potable water.

STORAGE TANKSHot Water A.S.M.E. Pressure VesselsGlass • Pre-Krete • Cement • Unlined

26

Features• All fabrication, welding, and testing performed in strict accordance with ASME codes, and continuously checked by ASME/National Board Inspections• Effective circulation of makeup and heater water• Maximum hot water storage and “draw” capacity• Broad selection of tank linings: • Unlined - Low cost storage of water for non-potable and non-sanitary use • Glass - Porcelain glass enamel for temperatures up to 160ºF • Cement - Heavy duty, resist cracking, good for temperatures to 180ºF • Pre-Krete - very suitable for soft, acidic or low pH water, for temperature up to 350ºF

Standard Equipment• Quality carbon steel construction, diameter 18" to 72"• Choice of: • SD: 125 psig ASME Section VIII tank • SJ: 150 psig ASME Section VIII tank • SW: 125 psig ASME Section IV (only diameter 24" to 42" available)• Vertical or horizontal orientation• Inspection openings for all SW tank and SD/SJ sizes 18" to 36"; 12" x 16" manway for SD/SJ tank sizes 42" to 72"• Unlined interior for SD and SJ tanks, glass lined interior for SW tanks

• Shop primered exterior• Carbon steel fittings for SD/SJ tanks and all SW tanks• Pipe leg couplings on vertical models

Optional Equipment• Glass, cement, or pre-krete lining on SD or SJ tanks• Vertical support • Pipe legs (with or without pads) • Ring base • Angle iron legs (with or without pads)• Horizontal support • Saddles• Skid mounted, 11/2" insulation & jacketing • 22 gauge galvanized steel jacket • Mirror finish stainless steel jacket• Stainless steel fittings• 11"x15" manways for 30" & 36" tanks

A.S.M.E.

A.S.M.E.

LW

Page 29: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

Hot Water Storage Tanks125 psig and 150 psig A.S.M.E.

* SD Models denote Section VIII Tanks. Use SW For Section IV @ 125 psig Tanks. SW models are available in 24" to 42" diameter only. Use SJ for Section VIII @ 150 psig Tanks.

(O.A.L.) Dimensions are nominal. ±2% tolerance should be allowed on dimensions and capacity. Order by Tank Model number. Add Tank Lining Code to Tank Model number when ordering. Glass lined tank supplied with pipe leg fittings. Saddles or brackets can be furnished welded for all lined tanks, or loose for unlined tanks only. Glass lined tanks limited to 10feet shell length. Tanks listed have shell lengths in even foot increments.

Tank sizes of 1802 to 1805 are available in SD and SJ Unlined only. 2404 to 2406 available in SW Glass Lined only.

Tank sizes of 6009, 6609, and 7209 are available in unlined, cement, and pre-krete lined only.

27

GLASS (G)Glass lining shall be ACE GLASS™ as applied by Ajax Boiler Inc. The inside surface of the tank shall be thoroughly cleaned prior to application. Ceramic glass lining shall be fused to the steel shell at 1500ºF. Lining shall have the same coefficient of expansion as the steel shell and be able to withstand abrupt changes in temperature. Lining shall be of a quality material and application as to resist corrosion. Magnesium and anodes are provided to help reduce electrolysis conditions. Suitable for potable water up to a maximum of 160ºF.

PRE-KRETE (K)An alternate to ATAHCO™ Cement, PRE-KRETE G-8 lining is suitable for storage of soft water with pH factor below 7, acidic water conditions. For steam condensate or applications with pH factor of 7 or greater, use PRE-KRETE C-17. The inside surface of the tank shall be thoroughly cleaned prior to application. The applied thickness is 5/8" and can withstand temperature to 350ºF (standard design). For higher temperatures please contact factory.

ATAHCO CEMENT (A)Cement lining shall be ATAHCO™ as supplied by Ajax Boiler Inc., or an approved equal. The inside surface of the tank shall be thoroughly cleaned prior to application. The entire surface shall then be coated with low soluble cement to a minimum thickness of 1/4" for tanks 48" diameter and under; and 3/8" thick for tanks 54" in diameter and over. The cement shall be of a type that resists corrosion and shall have the same coefficient of expansion as the steel shell. Suitable for potable water up to a maximum of 180ºF.

TANKMODEL

SIZEDIA. xO.A.L.

(Inches)CAPACITY

(Gallons)

SHIPPING WEIGHTTANK

SURFACEAREA

(Sq.Ft.)

U-UNLINEDG-GLASS A-CEMENT K-PRE KRETE

SWSD SJ SD SJ SD SJ

18" Dia. 13 Gal./ft. 25 #/ft. 25 5 sq.ft.1802 36 36 100# 100# N/A N/A 15 sq.ft.1803 48 49 125# 125# N/A N/A 20 sq.ft.1804 60 62 150# 150# N/A N/A 25 sq.ft.1805 72 75 175# 175# N/A N/A 30 sq.ft.

24" Dia. 23 Gal./ft. 32 #/ft. 40 #/ft. 6 sq.ft.2404 63 117 224# N/A N/A N/A 37 sq.ft.2405 75 140 256# N/A N/A N/A 43 sq.ft.2406 87 163 288# N/A N/A N/A 49 sq.ft.2407 99 186 320# N/A N/A N/A 55 sq.ft.

30" Dia. 35 Gal./ft. 48 #/ft. 61 #/ft. 85#/ft. 82 #/ft. 103 #/ft. 114 #/ft. 8 sq.ft.3004 66 190 334# 362# 485#* 494#* 650#* 747#* 47 sq.ft.3005 78 225 382# 410# 570#* 576#* 753#* 861#* 55 sq.ft.3006 90 260 430# 458# 655#* 658#* 856#* 975#* 63 sq.ft.3007 102 295 478# 506# 740#* 740#* 959#* 1,089#* 71 sq.ft.

36" Dia. 50 Gal./ft. 74 #/ft. 100 #/ft. 104 #/ft. 130 #/ft. 149 #/ft. 175 #/ft. 10 sq.ft.3604 69 275 462# 621# 642# 801# 912# 1,071# 60 sq.ft.3605 81 325 536# 695# 746# 905# 1,061# 1,220# 70 sq.ft.3606 93 375 610# 769# 850# 1,009# 1,210# 1,369# 80 sq.ft.3607 105 425 684# 843# 954# 1,113# 1,359# 1,518# 90 sq.ft.3608 117 475 758# 917# 1,058# 1,217# 1,508# 1,667# 100 sq.ft.

42" Dia. 70 Gal./ft. 117 #/ft. 117 #/ft. 154 #/ft. 159 #/ft. 222 #/ft. 222 #/ft. 11 sq.ft.4204 72 390 765# 765# 999# 999# 1,350# 1,350# 75 sq.ft.4205 84 460 882# 882# 1,153# 1,153# 1,572# 1,572# 86 sq.ft.4206 96 530 999# 999# 1,307# 1,307# 1,794# 1,794# 97 sq.ft.4207 108 600 1,116# 1,116# 1,461# 1,461# 2,016# 2,016# 108 sq.ft.4208 120 670 1,233# 1,233# 1,615# 1,615# 2,238# 2,238# 119 sq.ft.

48" Dia. 95 Gal./ft. 130 #/ft. 157 #/ft. 170 #/ft. 211 #/ft. 264 #/ft. 292 #/ft. 12 sq.ft.4804 75 510 955# 1,012# 1,214# 1,306# 1,655# 1,747# 85 sq.ft.4805 87 605 1,085# 1,142# 1,384# 1,476# 1,919# 2,011# 97 sq.ft.4806 99 700 1,215# 1,272# 1,554# 1,646# 2,183# 2,275# 109 sq.ft.4807 111 795 1,345# 1,402# 1,724# 1,816# 2,447# 2,539# 121 sq.ft.4808 123 890 1,475# 1,532# 1,894# 1,986# 2,711# 2,803# 133 sq.ft.

54" Dia. 120 Gal./ft. 176 #/ft. 210 #/ft. 245 #/ft. 279 #/ft. 349 #/ft. 383 #/ft. 14 sq.ft.5405 91 740 1,480# 1,650# 1,909# 2,079# 2,555# 2,725# 110 sq.ft.5406 103 860 1,656# 1,826# 2,154# 2,324# 2,904# 3,074# 124 sq.ft.5407 115 980 1,832# 2,002# 2,399# 2,569# 3,253# 3,423# 138 sq.ft.5408 127 1,100 2,008# 2,178# 2,644# 2,814# 3,602# 3,772# 152 sq.ft.

60" Dia. 145 Gal./ft. 195 #/ft. 235 #/ft. 279 #/ft. 319 #/ft. 405 #/ft. 445 #/ft. 15 sq.ft.6005 93 940 1,712# 1,912# 2,228# 2,428# 3,002# 3,202# 130 sq.ft.6006 105 1,085 1,907# 2,107# 2,507# 2,707# 3,407# 3,607# 145 sq.ft.6007 117 1,230 2,102# 2,302# 2,786# 2,986# 3,812# 4,012# 160 sq.ft.6008 129 1,375 2,297# 2,497# 3,065# 3,265# 4,217# 4,417# 175 sq.ft.6009 141 1,520 2,492# 2,692# 3,344# 3,544# 4,622# 4,822# 190 sq.ft.

66" Dia. 175 Gal./ft. 257 #/ft. 257 #/ft. 359 #/ft. 359 #/ft. 512 #/ft. 512 #/ft. 17 sq.ft.6605 95 1,155 2,172# 2,172# 2,790# 2,790# 3,717# 3,717# 141 sq.ft.6606 107 1,330 2,429# 2,429# 3,149# 3,149# 4,229# 4,229# 158 sq.ft.6607 119 1,505 2,686# 2,686# 3,508# 3,508# 4,741# 4,741# 175 sq.ft.6608 131 1,680 2,943# 2,943# 3,687# 3,867# 5,253# 5,253# 192 sq.ft.6609 143 1,855 3,200# 3,200# 4,226# 4,226# 5,765# 5,765# 209 sq.ft.

72" Dia. 210 Gal./ft. 281 #/ft. 282 #/ft. 401 #/ft. 402 #/ft. 581 #/ft. 582 #/ft. 19 sq.ft.7205 98 1,405 2,456# 2,669# 3,170# 3,383# 4,241# 4,454# 162 sq.ft.7206 110 1,615 2,737# 2,950# 3,571# 3,784# 4,822# 5,035# 181 sq.ft.7207 122 1,825 3,018# 3,231# 3,972# 4,185# 5,403# 5,616# 200 sq.ft.7208 134 2,035 3,299# 3,512# 4,373# 4,586# 5,984# 6,197# 219 sq.ft.7209 146 2,245 3,580# 3,793# 4,774# 4,987# 6,565# 6,778# 238 sq.ft.

AVAILABLE LININGS

Series

Page 30: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com

A.S.M.E.

A.S.M.E.

A.S.M.E.

3" x 3" x 1/4" Angle

7/8" Dia. Hole for 3/4" Dia. Bolt

B

45º

3" x 3" x 1/4" Angle

3" x 3" x 1/4" Angle 7/8" Dia. Hole for

3/4" Dia. Bolt

1/2" Dia. Bolt1/2" Dia. Bolt

3/16t x 1" wide steel strap

A

TANK DIA. (IN.)

A B WEIGHT

12" 73/8 7 2118" 101/2 11 3024" 131/2 15 3830" 161/2 19 46

Expansion TankWall BracketWith Tie Down Straps

Saddles

120º

AX

C

DB

4"

EC

TANK DIA. (IN.)

A B C D E WEIGHT(LBS.)

4" 41/2 3 1 2 1 56" 65/8 3 1 2 1 68" 85/8 3 1 2 1 6

10" 103/4 3 1 2 1 812" 123/4 3 1 2 1 914" 14 3 1 2 1 1516" 16 3 1 2 1 1518" 18 3 1 2 11/2 3520" 20 3 1 2 11/2 3822" 22 3 1 2 11/2 4224" 24 3 1 2 11/2 4526" 26 4 11/2 3 2 5528" 28 4 11/2 3 2 6530" 30 4 11/2 3 2 7536" 36 4 11/2 3 2 9042" 42 4 11/2 3 21/2 10048" 48 4 11/2 3 21/2 11554" 54 6 2 4 3 21060" 60 6 2 4 3 23066" 66 6 2 4 3 25072" 72 6 2 4 3 285

X - 1" Dia. hole type “B” saddles only.E - Leg coupling size type “P” saddles only.

Note: number of center supports dependent upon size of vessel.

Hold down straps may be provided at additional costs.

TANK DIA. (IN.)

A B C

12" 11-1/2 283/4 2 x 2 x 1/416" 15 30 2 x 2 x 1/418" 16-11/16 301/2 2 x 2 x 1/420" 18-3/8 31 2 x 2 x 1/424" 21-3/4 32 2 x 2 x 1/430" 26-11/16 343/4 3 x 3 x 1/436" 31-9/16 363/4 3 x 3 x 1/442" 36-3/8 381/4 3 x 3 x 1/4

Tank Stand

All dimensions are inches. If stand is used with a condensate return feedwater tank “B” dimensions should be increased. A

10 GA.

C

C

C

B24"

CC

10 GA.

C

Storage Tanks

28

(for unpackaged and/orun-insulated/jacketed tanks.)8" otherwise.

Page 31: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

A.S.M.E.

Pipe Legs TANK

DIA. (IN.)A B C D

STD. PIPELEG

LENGTHWEIGHT

(LBS.)12" 41/2 0 3-1 9 9 418" 6 11/2 3-11/2 8 91/2 724" 71/2 1 3-11/2 81/2 91/2 730" 9 21/2 3-11/2 11 131/2 936" 101/2 4 3-11/2 91/2 131/2 942" 12 41/2 3-2 131/2 18 1748" 131/2 6 3-2 12 18 1754" 15 8 3-21/2 10 18 1760" 161/2 9 4-21/2 9 18 2766" 18 10 4-21/2 10 20 3972" 191/2 101/2 4-21/2 91/2 20 39

C

D

A B

OPTIONAL:6" SQUARE X 1/4"THICK PLATE PAD.

These leg dimensions are for general applications.

Dimensions are in inches.

May add pads as option.

Ring Base TANK

DIA. (IN.)A B C D E WEIGHT

(LBS.)12" 12 5 9 6 11 1818" 13 5 15 6 11 3824" 14 5 21 6 11 5430" 151/2 5 27 6 11 7536" 161/2 5 33 6 11 9642" 171/2 5 39 6 11 15648" 19 5 45 6 11 19854" 201/2 5 51 6 11 35560" 24 91/2 57 12x16 131/2 47066" 25 91/2 63 12x16 131/2 54072" 261/2 91/2 69 12x16 131/2 620

A

B

CD

E

WITH BASE PLATE

WITH ANGLE CLIPS

WITH ANGLE RING

Angle Iron Legs TANK

DIA. (IN.)A B NO.

REQ. WEIGHT(LBS.)

12" 161/2 4 3 1718" 18 4 3 1824" 191/2 4 3 1930" 21 4 3 2036" 221/2 4 3 3542" 26 6 3 4048" 271/2 6 4 7654" 29 6 4 8160" 321/2 8 4 13366" 34 8 4 13772" 351/2 8 4 145

A

8"

B

OPTIONAL: HOLE (1-1/4")

Dimensions are in inches. TANK DIA. (IN.)

ANGLE PAD

12"-30" 2 x 2 x 1/4 4 x 4 x 1/436"-42" 3 x 3 x 1/4 6 x 6 x 1/448"-54" 3 x 3 x 3/8 6 x 6 x 1/460"-72" 4 x 4 x 3/8 8 x 8 x 3/8

29

OPTIONAL BASES

With pads optional.

A.S.M.E.

A.S.M.E.

Series

Page 32: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com30

Heat Exchanger & Combustion Design• All copper and bronze piping • ASME Section IV H or HLW rated to 160 psig, 250ºF / 210ºF• Front removable heat exchanger• Variable speed combustion blower control and speed feedback signal for assured low fire light off and high fire pre and post purge• Sealed combustion chamber for increased efficiency, reduced emissions and multiple venting configurations• Low NOx, high efficiency knit metal fiber burner• Powerful blower allows up to 60 feet of equivalent vertical exhaust venting without adjustments (1 elbow = 10ft)• Honeywell Air-Fuel Ratio Valve and Venturi• Replaceable Air Intake Filter

Control Specification • Flame Safe Guard Controller with integrated operating, modulating & high limit safety controls• User interface LCD panel with 4 buttons display boiler status information including sequence, lockouts, alerts, setpoints, controlled temperatures and flame signal• 4 to 20mA signal input for remote modulation• Digital input for remote reset and time of day setback• Modbus RS485 communication allows access to operating, safety and burner data• Lockout and safety alerts history record contains up to 15 detailed snapshots of the system when lockout occurred• Dual PID Load Combination control system for Central Heat and DHW loop• Interrupted pilot with spark ignition & air cooled UV scanner for monitoring pilot & main flame• Two single element temperature sensors for: Inlet & Outdoor Temperature• Three dual element safety limit (UL 353) temperature sensors for: Outlet, Stack & DHW Temp.• Outdoor Reset Control with programmable heating curve

• Algorithm prioritization for burner demand (Central Heating, DHW and Frost Protection) and firing rate limit (Stack and Boiler Delta-T)• Programmable safety and boiler protection features for: Frost protection, Slow Start, Delta-T Limit, Stack T Limit, Boiler T Limit, and DHW T Limit• Pump control contacts for Central Heat, DHW & System Pumps w/ purge time control & frost protection (pump included as additional option)• Three levels of password protection for end user, installer/service engineer and manufacturer• Additional interlock terminals for Pre-Ignition, Recycle and Lockout Interlocks

Operator Interface (Optional) • Local Operator Interface color touch screen display allows advanced configuration settings, remote monitoring, fault history, diagnostics and trend analysis of each boiler• System Operator Interface color touch screen display allows advanced configuration settings, remote monitoring, fault history, diagnostics, trend analysis and lead lag sequencing control of each boiler on multiple boiler configuration system

Control Options (Optional)• Communication Gateway Package • Remote Enable Relay• Annunciation Lamp Package • Boiler Status Relay• SPDT Fault Relay • Sensor Package• Alarm Bell with Silencing Circuit

Jacketing and Installation• Standard stainless steel indoor • Hinged front and top access panels• Easy intallation with just a pallet jack• Stainless steel or galvanized outdoor (Optional) • Red powder-coat with brushed aluminum door (Optional)

HIGH EFFICIENCYCONDENSING BOILERS• Up to 97% Thermal Effi ciency • Seven Models from 0.5 to 3.0 MBTU input• Up to 7.5:1 Turndown• Single Pass Copper Finned Heat Exchanger• Air Cooled Interrupted Pilot w/UV Scanner• Full modulation, Consistent Emissions with NOx <9 ppm and Clean Light Off• Small Footprint

Atlas Series ModelThe Atlas Series condensing boilers perform dependably and quietly, offering the highest effi ciency solutions for space heating, domestic and process hot water, low temperature applications such as snow melting, pool heating and low temp building loops. Modular design, low emmissions, advanced controls, and easy start-up make the Atlas Series the clear choice for all your high effi ciency needs.

Page 33: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

31

Optional red powder jacket and brushed aluminum door

1Based on 50ºF inlet water at 50GPM. Actual effi ciency may vary with operating conditions.2Based on 50ºF inlet water at 100GPM. Actual effi ciency may vary with operating conditions.All dimensions are inches are approximate and subject to change. For weight critical application, consult factory.

Specifi cations

SPECIFICATIONS A050 A075 A100 A150 A200 A250 A300

Input (BTU/hr) 500,000 750,000 1,000,000 1,500,000 2,000,000 2,500,000 3,000,000

Output (BTU/hr) @ 50ºF Input 470,000 705,000 940,000 1,410,000 1,880,000 2,350,000 2,820,000

Dimension (W x D x H) 29"x34"x41" 29"x34"x48" 29"x34"x54" 29"x34"x69" 34½"x39"x70" 34½"x39"x79" 34½"x39"x88"

Footprint (Sq.ft.) 6.85 6.85 6.85 6.85 9.35 9.35 9.35

Recommended Flow Rate 50 gpm 50 gpm 50 gpm 50 gpm 100 gpm 100 gpm 100 gpm

Pressure Drop 9 feet 12.5 feet 14 feet 15 feet 15 feet 17 feet 18 feet

Turndown 3.5:1 5:1 7:1 7.5:1 6.5:1 7:1 7.5:1

NOx Emissions @ 3% 02 <9 ppm <9 ppm <9 ppm <9 ppm <9 ppm <9 ppm <9 ppm

Min. Inlet Water Temp. Req. NONE NONE NONE NONE NONE NONE NONE

Max. Equivalent Exhaust Venting 60ft. 60ft. 60ft. 60ft. 60ft. 60ft. 60ft.

Mountable on Combustible Flooring YES YES YES YES YES YES YES

Sealed Combustion Chamber YES YES YES YES YES YES YES

Pre-mix Combustion YES YES YES YES YES YES YES

Vent Size (Intake / Exhaust) 4" / 6" 4" / 6" 6" / 8" 6" / 8" 8" / 10" 10" / 12" 10" / 12"

Gas Connection Size 1" 1" 1" 1¼" 1¼" 1¼" 1¼"

Water Connection Size 2" 2" 2" 2" 2½" 2½" 2½"

Gas Pressure Required 5-14" WC 5-14" WC 5-14" WC 5-14" WC 5-14" WC 5-14" WC 5-14" WC

Firing Mode Full Modulation Full Modulation Full Modulation Full Modulation Full Modulation Full Modulation Full Modulation

Condensing YES YES YES YES YES YES YES

Max. Thermal Effi ciency (25%) 97%1 97%1 97%1 97%1 97%2 97%2 97%2

Max. Thermal Effi ciency (100%) 94%1 94%1 94%1 94%1 94%2 94%2 94%2

Electrical Requirements 120V 60Hz 1Ph 120V 60Hz 1Ph 120V 60Hz 1Ph 120V 60Hz 1Ph 120V 60Hz 1Ph 120V 60Hz 1Ph 120V 60Hz 1Ph

Unit Weight (lbs) 590 685 770 840 1100 1350 1600

Series

Page 34: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com32

Atlas 2.0Atlas 2.5

Condensing Boilers

Atlas 3.0Optional red powder jacket and brushed aluminum door

Dimensions

Air Intake

Hot Water OUT

C

Gas Inlet

B

A

DE

Cold Water INExhaust Vent

½" Condensate Drain

F

H

I

J

G

1 For shipping dimension, add a maximum of 15" for piping. All dimensions are inches. 2 Estimated shipping weights. For weight critical application, consult factory.

A front replaceable heat exchanger and clip-on jacket give access to all components, while the sealed combustion system allows for complete fl exibility in installation. The modular design allows for simple multiple unit installations, and the on-board controls are readily interfaced with various communications systems. The full-featured, dependable and economical performance of the Atlas Series makes it the ideal solution for all of your water heating needs.

E.T.L. Listed

E.T.L. Canadian Listed(Gas & LPG Only)

C

A.S.M.E.

LW

CSA Compliant

UL 795 Compliant

A.S.M.E.

MODEL

A

WIDTH

B

DEPTH1

C

HEIGHT

DAIR

INTAKE

EGAS

INLET

FHOTOUT

GEXHAUST

VENT

HCOLD

IN

IHOTOUT

JDRAIN /

EXHAUSTEXHAUSTVENT DIA.

AIR INTAKE

VENT DIA.

WATERIN/OUT

DIA.

GASINLETDIA. WEIGHT2

A050 29" 34" 41" 35" 29" 23" 16" 11" 8" 14½" 6" 4" 2 1 590A075 29" 34" 48" 42" 36" 29" 16" 11" 8" 14½" 6" 4" 2 1 685A100 29" 34" 54" 48" 41" 36" 17" 11" 8" 14½" 8" 6" 2 1 770A150 29" 34" 69" 59" 53" 46" 17" 11" 8" 14½" 8" 6" 2 1¼" 840A200 34½" 39" 70" 58" 52" 45" 19" 13" 8" 17¼" 10" 8" 2½" 1¼" 1100A250 34½" 39" 79" 70" 60" 53" 20" 13" 8" 17¼" 12" 10" 2½" 1¼" 1350A300 34½" 39" 88" 79" 69" 62" 20" 13" 8" 17¼" 12" 10" 2½" 1¼" 1600

Page 35: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

NOTES

33

Series

Page 36: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com34

Condensing will occur during the combustion process when the combustion gases come in contact with cool heating surfaces of boilers and water heaters. Condensation will cause damage to all fi red boilers and water heaters.

The moisture from condensation will cause incomplete combustion which will reduce the combustion effi ciency and cause sooting of the boiler. Sooting will reduce the heat transfer effi ciency and clog the fl ue gas passages disrupting the combustion process. On atmospheric fi red boilers, clogged fl ue passages may cause fl ame roll out from the combustion chamber and a fi re hazard.

Moisture in the fl ue gases from condensation will cause rusting of the boiler tubes and the boiler stack and also damage boiler refractory and insulation.

Condensation can be prevented in properly designed boiler and water heating systems by maintaining inlet water temperatures above the dew point. Dew point, depending upon the atmospheric pressure, temperature and humidity conditions, will normally occur when the water inlet temperature is in the 120ºF to 130ºF range. It is generally accepted therefore, that 140ºF boiler water inlet temperature should be maintained to provide a small operating safety margin. Condensation damage can also be reduced by limiting cold start ups to once or twice a year. Night set back controls and delayed-system three way valves can minimize low temperature fi ring.

For low temperature applications such as water source heat pumps, low temperature heating systems, low temperature water heating application such as used in convalescent home, Ajax Boiler Inc. offer boiler and water heater “return loop blend” (RLB) packages. The RLB packages are furnished with manual valves for systems with relatively constant fl ow and temperature conditions. Failure to maintain 140ºF inlet water temperature will void your boiler warranty.

For a main loop fl ow of 3,520GPH, at a temperature rise of 30ºF, select Model B11G from the table. (Note: Maximum main loop supply temperature is 200ºF.)

For only main loop fl ow and temperature rise conditions, the boiler will heat a fraction of the main loop fl ow. The heated water will then be returned to the main loop where it will mix with unheated water to provide the desired loop temperature. For inlet water temperatures below 140ºF, some of the hot water exiting the boiler must be returned to the boiler water inlet to provide a blended inlet water temperature of 140ºF or higher. This return-blend action is activated by closing the blend valve until the temperature at the boiler inlet reaches 140ºF.

For boiler output higher than 1,200,000BTU/Hr, use multiple units.

LOW TEMPERATURE WATER HEATING SYSTEMSIZING CALCULATION AND EXAMPLE

TO SIZE: BOILER, CIRCULATORINPUT System Operating Conditions: Loop Flow (F1)GPM Loop Supply Temp. (T1)ºF Loop Return Temp. (T2)ºFSELECT Boiler Water Inlet Temp. (T3) Minimum Temp. 140ºF Boiler Water Outlet Temp. (T4) 180ºF to 200ºF

SIZING CALCULATION FORMULASHeat required to heat loop (required output) BTU/HR I1 = 500 F1(T1 - T2)Boiler input required BTU/HR I2 = I1 x 1.25Boiler Flow (boiler blend water) GPM F2 = F1(T1 - T2) / (T4 - T3)Flow required out of loop GPM F3 = I1 / 500 (T4 - T2)Circulator Flow GPM F4 = F2 - F3

SIZING CALCULATION EXAMPLEINPUT Flow and Temperatures: Normal LoadDesign Conditions: Input Loop Flow GPM F1 250 Loop Supply Temp. ºF T1 75 Loop Return Temp. ºF T2 70Boiler Operating Temperatures and Flow: Select Boiler Flow GPM F2 Boiler Water IN Temp. ºF T3 140 Boiler Water OUT Temp. ºF T4 200

Calculate: Heat required to heat loop (required output) BTU/HR I1 = 500 F1(T1 - T2) I1 = 500 (250) (75-70) I1 = 625,000 BTU/HR

Boiler input required BTU/HR I2 = I1 x 1.25 I2 = 781,250 BTU/HR

Suggest using size B8 Water Heater or Boiler - 800,000 BTU/HR Input

Boiler Flow (including blend water) GPM F2 = F1(T1 - T2) / (T4 - T3) F2 = 250 (75-70) / (200-140) F2 = 20.8 GPM

Flow required out of loop GPM F3 = I1 / 500 (T4 - T2) F3 = 625,000 / 500 (200-70) F3 = 9.6 GPM

Circulator Flow GPM F4 = F2 - F3

F4 = 20.8 - 9.6 F4 = 11.2 GPM

Return Loop Blend

Main Loop

Main Loop

T1

T4F2

F2

F1T2

T4F4

T3 F3

Page 37: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

35

Double-Wall Tube BundlesMeets Uniform Plumbing Code requirements for heating potable water. Prevents cross-contamination. Tested and certifi ed by the City of Los Angeles Testing Laboratory.

• Easy Inspections and low maintenance• Fully visible, 360º vented leak detection between tubesheets.• Bolting and gaskets for potable water and heating medium are completely independent.• Individual tube access for easy maintenance.• Optional: Tubesheet contacting potable water is solid 304 stainless steel.• Used to upgrade present single-wall tube bundles.• Available in storage semi-instantaneous water heaters and exchangers with copper or

cupro-nickel tubes and carbon steel or stainless steel tube sheets (Up to 400 PSIG with cupro-nickel tubes)

Double-Wall Protection PerformanceTube failure can be caused by corrosion, erosion, and vibration, and can result in the contamination of the domestic water system to be contaminated by a heating medium such as steam, hydronic water, glycol solution, etc. There is no practical way to have the heating medium sterile or free from harmful treatment compounds or corrosion by-products. A low pressure heating medium circuit does not ensure contamination protection of indirect, single-wall water heaters. Whether they are shell and tube, shell and coil, plate and frame, or any other type, all consist of relatively thin wall heat transfer surface separating the heating medium from the domestic water system. Therefore, the potential for cross contamination is real and in some instances contamination has occured. Several states and cities are now insisting on double-wall vented construction in all direct type domestic water heaters. Plumbing codes have also been re-written to include double-wall protection. Ajax Boiler has developed the most practical, “state-of-the-art” double tube wall heaters to preclude any possibility of contaminating the domestic water system.

The Ace Series double-wall is the most positive form of double tube wall construction available, with no sacrifi ce in water heater effeciency or performance over a single tube wall heater.

The heat transfer surface is 5/8" O.D. x .042" thick inner wall and 3/4" O.D. x .042" outer wall SB-75 copper tubing. The .042" dimensions are actual net tube wall thicknesses which equal .084" thickness of total wall separation. This is more than twice the thickness of many single wall water heater products. Both inside and outside tube surfaces are smooth (prime) with no fins or surface irregularities to promote scale formation or corrosion attack.

Double-wall tubing has a similar overall heat conductivity as a single wall tube of equivalent wall thickness. The heat transfer capabilities were determined by actual tests conducted at the Ajax Boiler facilities. Each tube has multiple parallel and continuous vent paths.

Page 38: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

www.ajaxboiler.com36

The Ajax Boiler Factory limited warranty provides assurance that all products are free from manufactures defects at the time of shipment and meet specifi cations and performance described in the product literature. It is important to understand the difference between a factory warranty and an installed warranty. There are many factors that can occur to the products after they are shipped that the company has no control over and cannot fully verify. These include: 1. Hidden damage during the shipping 2. Handling damage 3. Damage during storage 4. Installation conditions 5. Other unknown variables in the system design, operations, maintenance, pulsation and vibrations.

The installed warranty is the responsibility of the architect, specifying engineer, contractor and or owner who jointly have control over the application, installation, location, operating and maintenance conditions. The AJAX BOILER INC. warranty excludes extended liabilities. Extended liability typically occurs when products are installed without proper drainage, fl ooding containment or when safety devices are not tested and repaired or replaced when needed. Product problems are often caused by the condition of the water, the lack of water treatment and or the improper treatment of the water, insuffi cient combustion air, improper draft conditions, bolts not re-tightened, pipes not fl ushed and cleaned of oil, metal chips, rags, vibration and pulsation etc. These are installation, operating and/or maintenance conditions that are beyond the seller’s responsibility and are not covered by the factory warranty, but may be covered by the installer’s warranty. The factory warranty covering company products is based upon extensive product development and testing. Combustion products under go certifi cation testing and approvals to Underwriters Laboratory standards. Auditing of the production of combustion products is conducted by a nationally recognized testing laboratory. Pressure vessel products are designed and manufactured to American Society of Mechanical Engineering (A.S.M.E.) and National Board (NB) Design standards. Design reviews, factory product manufacturing quality inspections and testing are carried out by a third party National Board authorized inspection agency. AJAX BOILER INC. products have proven themselves in service for over 85 years which indicates that the company products perform exceedingly well when normal installation, operating

and maintenance conditions exist. The following is a review from the terms and conditions of sale. Also included in paragraph two, below, is the AJAX BOILER INC. non-conformance policy.

1. AJAX BOILER INC. warrants its products against defective material and/or workmanship only. The warranty does not apply to operational failures, electrical failures, gasket leaks, and or other malfunctions caused by improper application, installation and or maintenance.2. It is the buyer’s responsibility to inspect and accept the product, when received, as conforming to their purchase order, specifi cations and approved drawings. All claims for non-conformance, errors, shortages, etc. must be made within 10 days after receipt of the shipment.3. AJAX BOILER INC. do not provide a warranty or guarantee, express or implied, in any manner, form, usage of trade, merchant-ability or fi tness which extend beyond the product description and quotation.4. AJAX BOILER INC. liability is limited to the factory repair or replacement of warranty failures, or non-conformance, upon the return of the product to the factory.5. AJAX BOILER INC. is not liable for any direct or consequential damages.6. The AJAX BOILER INC. warranty is based upon section 23161(2) of the uniform commercial code and is printed in the terms and conditions of sale which is referenced in every quotation, on the back of sales order acknowledgements and invoices. It is legally correct and is an industry standard policy.

THERMAL SHOCK In addition to our standard one (1) year warranty against defective parts and workmanship, AJAX BOILER INC. provides the following guarantee with all commercial hot water, forced circulation, space heating boilers: AJAX BOILER INC. guarantees this new boiler pressure vessel for ten (10) years after date of installation from damage due to thermal shock. Thermal shock occurs when cold makeup water, up to 150°F less than the boiler water outlet temperature, is added directly into the boiler while the boiler is operating within the normal temperature range from 140°F to 250°F with a temperature rise from 20°F to 40°F. This guarantee shall cover damage to the boiler tubes, tube headers, and tube sheets when such damage is attributed to unequal expansion, poor circulation and/or other causes quite often described as “thermal shock.” This guarantee does not cover damage or failures that can

Page 39: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers

37

be attributed to corrosion, condensation, scale, boiler treatment chemicals, dirt accumulation, low water conditions, or any other abnormal operating conditions. The liability of AJAX BOILER INC. is limited solely to the replacement of the complete pressure vessel, with tubes, if found by our inspection to be damaged by thermal shock. In no event shall AJAX BOILER INC. be held liable for replacement labor charges or for freight or handling charges.

AJAX BOILER INC. provides a limited warranty on its products aganst defective material and/or workmanship only. This limited warranty is not applicable to operational failures, electrical failures, gasket leaks, wear or malfunctions caused by improper application, installation, and/or maintenance.

The following Limited Warranty periods are from date of shipment: Boiler Pressure Vessels: One year.Carbon Steel Tank and Heat Exchanger Pressure Vessels: One year.Stainless Steel Tanks: Three years.Boiler Copper Fin Coils: Three years.High Effi ciency Condensing Boiler: One Year (Three years on Coil).Single-Wall or Double-Wall Tank/Exchanger Coils: One year.Single-Wall or Double-Wall Mini-Packs: One year.Atlas Series Condensing Boiler: One Year.Linings: (Pro-Rated Warranty) Section VIII Tanks: Glass 36” dia. and above (fi ve years). Glass 30” dia. and under (one year). Cement (fi ve years). Prekrete (ten years). In Section IV Tanks: Glass (one year).Controls: Components manufactured by other than AJAX BOILER INC. such as controls, instruments, forced draft burner, etc., provided with the boilers and packaged products are not covered by the AJAX BOILER INC. Warranty. However, AJAX BOILER INC. extends to the customer the same warranty provided by the manufacturer to AJAX BOILER INC. The customer shall receive the full benefi ts of adjustments made to AJAX BOILER INC. by the manufacturer.

Any claim for adjustment under this limited warranty must be made within the warranty period. AJAX BOILER INC.’s liability shall be limited to factory repair

or, at AJAX BOILER INC.’s option, replacement of all parts which, upon test and examination by AJAX BOILER INC., prove to be defective material and or workmanship and within the above limited warranty. If required by AJAX BOILER INC., parts which are claimed to be defective must be promptly delivered to the AJAX BOILER INC. facility, transportation charges prepaid. This warranty does not cover the cost of labor, removal, or installation of the warranted item during the limited period. This warranty is limited to the above and applies only for the period set forth. AJAX BOILER INC. will not be liable for any loss damage, direct, incidental or consequential damages of any kind, whether based upon warranty, contract, negligence or strict liability and arising in connection with the sale, use or repair of the products. AJAX BOILER INC.’s maximum liability shall not exceed the contract price for the products or component claimed to be defective or unsuitable. AJAX BOILER INC. does not warrant the product’s merchantability or fi tness for any particular purpose and in no event shall be held responsible for any consequential damages.

For complete Limited Warranty conditions see Section G and H under terms and conditions of sale.

The brand and product names contained within are trademarks or registered of their respective holders. Performance, dimensions, specifi cations are effective with date of issue and are subject to change without prior notice. AJAX BOILER INC. maintains a policy of continuous improvements and therefore reserves the right to change specifi cation without notice. AJAX BOILER INC. cannot be responsible for errors in typography or photography.

Page 40: Table of Contentsdemo.imecmep.com/.../Ajax-AceSeriesWaterHeaters.pdf• Inclined water tube boilers • High & low pressure steam boilers • Unfi red steam boilers • Heat exchangers