Sheet 1 of 1 B01-0200.xls - Front sheet
02
Originator / Contractor Code
Short Requisition No / PO Identifier Sheet Rev
FC EL0016-A01 02
Alternative Document No: (if applicable):
Rev Orig. Chk'd App'd
02 GR DH NCR
01 GR DH NCR
Code
1
2
3
4
5
6
Date
UPDATED SUBMISSION
Accepted (Reviewed and Agreed)
Comments to Incorporated and Resubmitted
Rejected, Do Not start work (Comments to be incorporated and resubmitted)
Description of Code
DateDescription
INITIAL SUBMISSION
Signature of Purchaser'sResponsible Engineer
SUPPLIER DOCUMENT FRONT SHEET
Supplier Name: ABB Ltd
For Information
20-Nov-13
18-Feb-14
Project ID
CLB
Equipment Tag No(s):
Supplier Document No:
Document Title:
Z-89902
N/A
GENERAL ARRANGEMENT - GM TEMPORARY SUBSTATION
Supplier Document Revision No.
Purchaser Document Number
Sequence no.
0200
SDDR code
B01
Purchaser Review of Supplier Document
Cancelled / Superseded
As-Built
8000
10061001600
100
100
1450 LOUVERS 5047
100
953
3000
240015004100
650
100
1580
610
610
100
100
810
1180
810
369 821 410
535 565157.5 435
65
550 550 435
65
535
65
535
65
535 342.5 600 65
6525
0
430
210
430
210
210
430
1600
2300 1500 STRUCTURAL OPENING 2300
6100
2800
100
100
100
100
100
1501200
800
150
750
750
350
100
150500300
HV S
IDE
LV S
IDE
HV S
IDE
LV S
IDE
670 W
HEEL
CRS
670 WHEEL CRS
410821369
360 115090
500
375
CABLE APERTURE THROUGH BASE FRAME& FLOOR PLATE. C/W MARINE GRADEALUMINIUM GLAND PLATE TO U/SIDE.
(ACCESS FOR INCOMING HV & EARTH CABLES)
7 OFF CABLE APERTURES THROUGH BASE FRAME& FLOOR PLATE. C/W MARINE GRADE ALUMINIUMGLAND PLATES TO U/SIDE.(ACCESS FOR SWITCHBOARD CABLES)
CABLE APERTURE THROUGH BASE FRAME& FLOOR PLATE. C/W MARINE GRADE ALUMINIUMGLAND PLATES TO U/SIDE.(ACCESS FOR CABLES / SERVICES)
INTERNAL PLAN VIEW AT CEILING LEVEL
INTERNAL PLAN VIEW (INCLUDING ALL FLOOR APERTURES)
REFERENCE TABLE OF EQUIPMENT FOR GM TEMPORARY SUBSTATION MODULE (TAG No. Z-89902)
REF EQUIPMENT TAG DESCRIPTION QTY. WIDTH. (mm) DEPTH (mm) HEIGHT (mm) WEIGHT (kg) HEAT LOSS (kW) SUPPLIER COMMENTS
01 ETR-89902 1000 kVA TRANSFORMER 1 1580 849 1918 2249 11 ABB
02 ESW-89902 690V SWITCHBOARD 1 5050 750 2300 2850 2.858 ABB03 ECP-89902 SWITCHBOARD REMOTE CONTROL 1 400 250 600 - - ABB
04 EDB-89902 690/230V, 100 kVA LV DIST. BOARD + TRANSFORMER 1 1200 800 2200 800 - ABB
05 EIN-89902 TRIP & CLOSE UPS 1 750 455 1252 180 - ABB06 HCN-89902 HVAC EXTERNAL CONDENSER UNIT 1 970 450 845 83 - GAT07 HAH-89902 HVAC INTERNAL AIR HANDLING UNIT 1 950 950 333 81 - GAT08 HCP-89902 HVAC CONTROL PANEL 1 - - - - - GAT09 DRP-89902 FIRE PANEL 1 - - - - - CFS10 DSA-89902-01 SMOKE DETECTOR 2 - - - - - CFS11 DSA-89902-02 SMOKE DETECTOR 2 - - - - - CFS12 DHR-89902-01 RoR HEAT DETECTORS (WEATHERPROOF) 2 - - - - - CFS13 DHR-89902-02 RoR HEAT DETECTORS (WEATHERPROOF) 2 - - - - - CFS14 MAC-89902 FIRE MANUAL CALL POINT 1 - - - - - CFS15 DAL-89902-01 FIRE SOUNDER BEACON IP65 (RED) - INTERNAL 1 - - - - - CFS16 DAL-89902-02 FIRE SOUNDER BEACON IP65 (RED) - EXTERNAL 1 - - - - - CFS17 SFC-89902 CO2 FIRE EXTINGUISHER & ID SIGN 1 - - - - - CFS18 EME-89902 STAIRS & LANDINGS 1 - - - 860 - BRADGATE19 ES3-89902-01 DOMESTIC ELECTRICAL TWIN SOCKET 230V 60 Hz 16A 2 - - - - - BRADGATE 3 PIN (RCD PROT.)
20 ES3-89902-02 DOMESTIC ELECTRICAL TWIN SOCKET 230V 60 Hz 16A 2 - - - - - BRADGATE 3 PIN (RCD PROT.)
21 EFL-89902-01 FLOURESCENT LUMINAIRE C/W EMERGENCY BACK-UP 4 - - - - - BRADGATE
22 EFL-89902-02 FLOURESCENT LUMINAIRE C/W EMERGENCY BACK-UP 4 - - - - - BRADGATE
23 EFL-89902-03 FLOURESCENT LUMINAIRE C/W EMERGENCY BACK-UP 4 - - - - - BRADGATE
24 EFL-89902-04 FLOURESCENT LUMINAIRE C/W EMERGENCY BACK-UP 4 - - - - - BRADGATE
25 EIS-89902 ELECTRICAL LIGHT SWITCH ISOLATOR 1 - - - - - BRADGATE
26
27 EFL-89902-05 LIT EMERGENCY EXIT SIGN 1 - - - - - BRADGATE
28 HAC-89902-03 15 kVA 3 PHASE AUTOTRANSFORMER 1 350 242 353 25 - BRADGATE HVAC SUPPLY
29 EWL-89902 COMMON FAULT WARNING LIGHT 1 - - - - - BRADGATE
30 SEK-89902 ELECTRICAL INTERVENTION KIT (LIFE SAVING KIT) 1 840 754 270 20 - ABB
31 EEL-89902 KEY BOX/SAFE 1 190 50 250 - - BRADGATE
32 RSL-89902 PORTABLE EMERGENCY HAND LAMP 1 - - - - - BRADGATE
NOTES:
ALL EXTERNAL HINGES AND REMOVABLE PANELS ARE FIXED WITH M8 STAINLESS STEEL TORX SECURITYSCREWS.
ALL REMOVABLE PANELS ARE FIXED WITH M10 STAINLESS STEEL TORX SECURITY SCREWS.
ALL DOORS AND REMOVABLE PANELS ARE 'EARTH BONDED'.
ALL ELECTRICAL ITEMS AS SPECIFICATION.
NON-DESTRUCTIVE TESTING (NDT):
ALL LIFTING LUG WELDS AND LIFT PATH WELDS ARE TO BE MAGNETIC PARTICLE TESTED TO BRADGATE WORKSPROCEDURE 010.INSPECTION / TEST RESULTS ARE TO BE RECORDED.
MATERIAL SPECIFICATION:
STRUCTURAL:ALL RHS AND SHS SECTIONS TO BS EN 10210 S355J2HALL PLATE MATERIAL OVER 5mm THK. TO BS EN 10025 S355J2ALL PLATE MATERIAL 5mm AND UNDER TO BS EN 10025 S275JRALL ALUMINIUM GLAND PLATES 6mm MARINE GRADE, 5083 - H111
CERTIFICATES FOR ALL STRUCTURAL MATERIALS WILL BE ISSUED IN PROJECT DOCUMENTATION.
ROOF:OUTER SKIN 14swg (2.0mm) ZINTEC SHEET.INNER SKIN 16swg (1.6mm) ZINTEC SHEET.TREATMENT 100mm RWA45 MINERAL WOOL.
WALL:OUTER SKIN 14swg (2.0mm) STEEL CORRUGATED SHEET.INNER SKIN 18swg (1.2mm) ZINTEC SHEET.TREATMENT 100mm RWA45 MINERAL WOOL.
FLOOR:STRUCTURE 300x100x46 UKPFC PERIMETER BEAMS.STRUCTURE 260x90x35 UKPFC CROSS BEAMS.STRUCTURE 125x65x15 UKPFC CROSS BEAMS.TRIMMERS 10swg FOLDED CHANNEL.FLOOR PLATE 5mm PLAIN STEEL PLATE.GLAND PLATES 6mm THK. MARINE GRADE ALUMINIUM PLATE.TREATMENT 100mm RWA45 MINERAL WOOL.
EARTH BAR 50x6 THK.FLAT NON INSULATED COPPER
DOOR FURNITURE DETAILS:
ACTIVE LEAF DOOR FURNITURE:EXTERNAL STAINLESS STEEL DOOR HANDLE EXIDOR (0210081005) LEVER OPERATED C/W EURO-PROFILECYLINDER & THREE KEYS.INTERNAL EXIDOR (0210180324) 3 POINT LATCHING EMERGENCY PANIC BAR & DOOR GEAR.INTERNAL & EXTERNAL PULL HANDLES (HENDERSON 436)DOOR STAY, BRADGATE STANDARD BCL-DS-01
INACTIVE LEAF DOOR FURNITURE:TOP & BOTTOM SPRING LOADED SHOOT BOLTS.
HINGES:FURGOCAR 304 STAINLESS STEEL MAINTENANCE FREE .
WEATHER LOUVERS (TRANSFORMER ROOM):
EXTERNAL WEATHER LOUVERS COMBINED WITH INTERNAL MESH GIVE AN IP33 PROTECTION RATING.
EARTH BAR:
INTERNAL HIGH LEVEL PERIMETER EARTH BAR, 50x6 thk. UN-INSULATED PLAIN COPPER MOUNTED ON TOP HATFOLDED SECTIONS. WITH DROPPERS & THROUGH WALL EXTERNAL CONNECTION POINTS. NOTE THAT ONLY THEHORIZONTAL CABLE CONNECTION EARTH BAR LENGTH WILL BE MOUNTED ON INSULATION BOBBINS. BOLTEDDISCONNECT LINK AT LOW LEVEL.
STAIR & LANDING:
STAIRS & LANDINGS ARE TO THE BRADGATE STANDARD STEEL CONSTRUCTION DESIGN CONFORMING TO THESTANDARDS OUTLINED IN EEMUA PUBLICATION 105 SEVENTH EDITION ' FACTORY STAIRWAYS, LADDERS ANDHANDRAILS'. LANDING GRATING IS SERRATED & STAIR TREAD NOSING IS NON-SLIP. ALL STAIRS & LANDINGSCOMPONETS ARE SUPPLIED WITH EARTH BONDING TAPPING POINTS. ALL STAIRS & LANDINGS COMPONENTS AREFINISHED 'HOT DIP GALVANISED' IN ACCORDANCE WITH BS EN ISO 1461:2009NOTE, THAT STAIRS & LANDINGS ARE DESIGNED FOR PERSONNEL ACCESS USE ONLY!I.E. NO EQUIPMENT IS TO BE PLACED ON THE LANDINGS.
UNDERSTRUCTURE:
THE UNDERSTRUCTURE IS DESIGNED AS A BOLT TOGETHER SET OF FRAMES.THERE ARE A TOTAL OF SIX FRAMES, TWO ALONG EACH SIDE & ONE EITHER END.THE MODULE WILL BE CONNECTED TO THE UNDERSTRUCTURE USING BRADGATE DESIGNED CLAMPS.THE UNDERSTRUCTURE WILL BE SUPPLIED WITH ADDITIONAL BRADGATE DESIGNED CLAMPS ALLOW THE WHOLESTRUCTURE & MODULE TO BE SECURELY FASTENED DOWN WHEN INSTALLED AT SITE.THE CLAMPS WILL BE FASTENED DOWN AT SITE BY USING MECHANICAL FIXINGS INTO THE CIVILS FOUNDATION /CONCORSE AREA. NOTE IT IS THE RESPONSIBILITY OF OTHERS TO SELECT & SUPPLY THE CORRECT MECHANICALFIXINGS FOR THE CLAMPING DOWN.THERE IS PROVISION PROVIDED TO FIT EARTH BONDING BETWEEN THE MODULE & THE UNDERSTRUCTURE FRAME& PROVISION TO EARTH BOND BETWEEN EACH OF THE UNDERSTRUCTURE FRAMES.THE UNDERSTRUCTURE WIL BE 'HOT DIP GALVANISED' IN ACCORDANCE WITH BS EN ISO 1461:2009
MODULE PAINT SPECIFICATION:
PAINT SYSTEM BRADGATE STD SPEC 005 (OFF SHORE).EXTERNAL DFT 220 MICRONS.INTERNAL DFT 150 MICRONS.
OUTSIDE BS 4800 10-A-05 GOOSEWING GREYINSIDE BRADGATE STANDARD WHITE.FLOOR BRADGATE STANDARD BLACK.UNDERSIDE BRADGATE STANDARD BLACK UNDERSEAL.
TRANSPORT & STORAGE:
ALL BUILDING DOORS WILL BE SECURED WITH A SCREWED RETAINING PLATE.ALL EXTERNAL LOUVERS WILL BE TEMPORARILY BOARDED WITH PLYWOOD SHEET C/W PLASTIC MEMBRANE.DURING TRANSPORTATION.TEMPORARY PLYWOOD BOARDING OF THE HVAC EXTERNAL CONDENSER.DURING LENGTHY SEA TRANSIT & ANY STORAGE, IT IS RECOMENDED THAT TEMPORARY BACK GROUND HEATINGIS USED TO ALLEVIATE THE ONSET OF A DAMP ATMOSPHERE.THE UNDERSTRUCTURE SUPPORT FRAMES, STAIRS & LANDINGS WILL BE SHIPPED IN STANDARD ISO CONTAINERS.
APPROXIMATE WEIGHTS AS SUPPLIED BY BRADGATE CONTAINERS LTD:
EMPTY MODULE ------------------------------------------------------------------- = 10500 kgINSTALLED EQUIPMENT SUB TOTAL ---------------------------------------- = 6288 kgBRADGATE ELECTRICAL EQUIPMENT (ESTIMATED.) ---------------- = 812 kg
TOTAL CALCULATED WEIGHT = 17600 kg
PLEASE NOTE THAT THE EQUIPMENT INDIVIDUAL WEIGHTS SHOWN HAVE BEEN TAKEN FROMINFORMATION/DRAWINGS SUPPLIED TO BRADGATE CONTAINERS LTD. CUSTOMER TO ADVISE IF ANY OF THEEQUIPMENT WEIGHTS ARE INCORRECT PRIOR TO MANUFACTURE OF THE MODULE.
LIFTING & RIGGING OF MODULE:
4 OFF TOP LIFTING LUG POINTS ARE PROVIDED, NOTING THAT THESE LIFTING LUGS ARE ONLY TO BE USED FORLIFTING A FULLY FITTED OUT MODULE ONLY! THE UNDERSTRUCTURE OR STAIRS & LANDINGS MUST BE LIFTEDSEPERATLY. SEE LIFTING & RIGGING DRAWING 13239-1-5 FOR DETAILS.
0308 09 04
05
02
01
05
01
07
06
06
12
10
21 22
23 24
17
14
25
STAINLESS STEEL TRANSITFRAME FOR POWER CABLES(S.S. TYPE - TO STOP EDDY CURRENTS)
11
13
500
300
500mm WIDE LADDER RACK CARRYINGPOWER SERVICE CABLES INCLUDING ANUPPER CABLE TRAY CARRYING SIGNAL CABLES
300mm WIDE LADDERRACK CARRYINGPOWER SERVICE CABLES
RUBBER MAT IN FRONT OF SWITCHBOARDS
28
02
14
25
17
2715
0308 09
16
STEEL TRANSIT FRAMEFOR SIGNAL CABLES
M12 PERIMETER EARTH BAR THRO'WALL EXTERNAL CONNECTION
M12 PERIMETER EARTH BAR THRO'WALL EXTERNAL CONNECTION
30
30
28
04
1100
800
150
31
31
1000
MAT
29
455
31
THIS DRAWING IS THE SOLE PROPERTY OF 'BRADGATE CONTAINERS LTD' AND MAY NOTBE COPIED OR USED FOR ANY PURPOSE OTHER THAN THAT FOR WHICH IT IS SUPPLIEDWITHOUT THE EXPRESS WRITTEN PERMISSION OF 'BRADGATE CONTAINERS LTD' (©2013)
BRADGATE CONTAINERS LTD. LEICESTER ROAD,
SHEPSHED, LEICS.
LE12 9EG
ISSUE SHEET SIZE
A0
BQ/
THIRD ANGLE PROJECTION
IF IN DOUBT ASK - DO NOT SCALE GENERAL FABRICATING TOLERANCES
ALL DIMENSIONS UP TO & INCLUDING 300 ±1 IN MILLIMETRES 301 UP TO 1500 ±2UNLESS STATED ABOVE 1500 ±3
DESCRIPTION
ORIGINAL ISSUE
ABB Ltd.
30/7/13G.N. Rogers17433
1:20
N/A NCR
DH 31/7/13
31/7/13
Equipment Layout of Generation Substation Module(690V) for BP Clair Ridge Temporary Substations
13239-1-1 D 1
SUPPLIER DRAWING DECAL
ProjectID
Alternative Document No.
1- Accepted (Reviewed andAgreed)
2- Comments to be Incorporatedand Resubmitted
Signature Date
3- Rejected, Do Not Start Work(Comments to beIncorporated andresubmitted)
4- For Information
Review Status
Short RequisitionNo/PO Identifier
Sequence Sheet. Rev
5- Cancelled/Superseded
6- As Built
Purchaser Document Number
Originator/ContractorCode
SDDRCode
CLB- AA- AANNNN-ANN ANN- NNNN- (NN) NN
DRAWING TO BE READ IN CONJUNCTION WITH SHEET 2
B ALLUPDATED INLINE WITH COMMENTS
BY AMEC ON 8/8/13.THE FOLLOWING NOTE SUBSECTIONS
ALSO UPDATED; MATL. SPEC.DOOR FURNITURE DETAILS.
STAIR & LANDINGUNDERSTRUCTURE.
06.09.13
C ALLUPDATED INLINE WITH COMMENTS
BY AMEC REC'D ON 11/9/13. 19.11.13
D 4C4F
LIGHTING & SMALL POWER DIST. BOARD(WAS ITEM 26) REMOVED & TABLEUPDATED INLINE WITH CUSTOMER
COMMENTS DATED 22/1/14
03.02.14
PLAN VIEW ON MODULE ROOF
Y
8000
SIDE ELEVATION
END VIEW
END VIEW
4 OFF LIFTING LUGS
7850 LIFT LUG CRS.75 75
M16 SAFETY HARNESS BOSSES(TYPICAL 8 POSITIONS)
TRANSFORMER ROOM VENTILATIONWEATHER LOUVERS WITH MESHPANEL TO INSIDE (SEE NOTES).
8000
SIDE ELEVATION
7850 LIFT LUG CRS. 7575
UNDERSTRUCTURE BOLT TOGETHER FRAMESSEE NOTES & DRAWING 13239-1-6 SHEET 1
RETANGULAR BASE EYE PLATESFULLY WELDED TO SIDE & END RAILSFOR LASHING DURING TRANSPORTATION(7 POSITIONS EACH SIDE & 4 POSITIONS EACH END)
2255
CLE
ARAN
CE H
T.
2555
3400
845
1094.5405.5
FULLY LINED REMOVABLE HEADER PANEL TO ALLOW EQUIPMENTACCESS FITTED WITH 2 OFF M12 EYEBOLTS TO BS4278. FULLYSEALED USING NEOPRENE BETWEEN PANEL & MODULE WALL
HVAC SERVICES PASSTHROUGH TRANSIT
3040 OVER LIFT LUGS
30001400 APPROX.
4400 APPROX.
3040 OVER LIFT LUGS
REMOVABLE BOTTOM THREASOLDTO ALLOW TRANSFORMER INSTALLATIONOR REMOVAL I.E. GIVING CLEAR ACCESS
TO AT FLOOR LEVEL
2795
STR
UCTU
RAL O
PENI
NG
BOLT-ON UN-LINNED CORRUGATED REMOVABLE END PANEL.C/W A PAIR OF M20 EYEBOLTS TO BS 4278 POSITIONED AT THE TOP CORNERS.APERTURE SIZE SHOWS STRUCTURAL OPENING. NOTING THAT THIS IS THE ONLY ACCESSIN TO THE TRANSFORMER ROOM.
2600 STRUCTURAL OPENING
5 FLO
OR P
LT.
3000
1800
100 2800 100
200
5 FLO
OR P
LT.
2102160 REF.
1675
125
HVAC AHU CONDENSATEDRAIN PASSES OUT THRO'
THE FLOOR
LADDER RACK CARRYINGPOWER SERVICE CABLES
430 APER.
06
06
06
07
18
18
18
CABLE TRAY CARRYINGSIGNAL CABLES
04
19
20
25
14
27
1500 2400
02
VERTICAL EARTH BAR MOUNTEDON ISOLATORS FOR CONNECTING
OF FIELD EARTH CABLES RISINGUP THROUGH FLOOR APERTURE
EARTH BAR BOLTED DISCONNECT LINK
EARTH BAR RISER MOUNTEDTO INNER WALL ON STEEL
BRACKETS (NON-ISOLATED)
PERIMETER EARTH BAR MOUNTEDTO INNER WALL ON STEEL
BRACKETS (NON-ISOLATED)
EARTH BAR RISER MOUNTEDTO INNER WALL ON STEEL
BRACKETS (NON-ISOLATED)
EARTH BAR RISER MOUNTEDTO INNER WALL ON STEELBRACKETS (NON-ISOLATED)
06
EARTH BOSS TAPPED M12(EXTERNAL BUILDING EARTH CONNECTION)
EARTH BOSS TAPPED M12(EXTERNAL BUILDING EARTH CONNECTION)
EARTH BOSSES TAPPED M12 WELDEDTO MODULE & REMOVABLE PANEL.
CONNECTED WITH COVERED EARTH BRAID
4000 4000
UNDE
RSTR
UCTU
REFR
AME
SPLIT
M12 PERIMETER EARTHBAR EXTERNAL CONNECTION
SECTION A-A
1500
U/S
TRUC
T.36
63 M
ODUL
E HT
.
5163
OVE
RALL
HT.
3000
A
A
TRANSFORMER ROOM VENTILATIONWEATHER LOUVERS WITH MESHPANEL TO INSIDE (SEE NOTES).
1629
920.5
LADDER RACK CARRYINGPOWER CABLES
375500 APER.1925100 100
5 FLO
OR P
LT.
1829
.5
17
3000
01
SIGNAL CABLE TRANSIT FRAME
POWER CABLE TRANSIT FRAME
CABLE APERTURE C/W MARINEGRADE ALUM. GLAND PLATE
030908
B
B
EARTH BOSS TAPPED M12(LANDING TO BUILDING EARTH CONNECTION)
EARTH BOSS TAPPED M12(EXTERNAL BUILDING EARTH CONNECTION)
03
17
30
1728
31
18
!Warning
No Equipment is tobe placed or wheeledonto the landing area
WARNING SIGN SHOWN, FITTEDTO INSIDE OF DOOR
THIS DRAWING IS THE SOLE PROPERTY OF 'BRADGATE CONTAINERS LTD' AND MAY NOTBE COPIED OR USED FOR ANY PURPOSE OTHER THAN THAT FOR WHICH IT IS SUPPLIEDWITHOUT THE EXPRESS WRITTEN PERMISSION OF 'BRADGATE CONTAINERS LTD' (©2013)
BRADGATE CONTAINERS LTD. LEICESTER ROAD,
SHEPSHED, LEICS.
LE12 9EG
ISSUE SHEET SIZE
A0
BQ/
THIRD ANGLE PROJECTION
IF IN DOUBT ASK - DO NOT SCALE GENERAL FABRICATING TOLERANCES
ALL DIMENSIONS UP TO & INCLUDING 300 ±1 IN MILLIMETRES 301 UP TO 1500 ±2UNLESS STATED ABOVE 1500 ±3
DESCRIPTION
ORIGINAL ISSUE
ABB Ltd.
30/7/13G.N. Rogers17433
1:30
N/A NCR
DH 31/7/13
31/7/13
G.A. of Generation Substation Module (690V)for BP Clair Ridge Temporary Substations
13239-1-1 D 2
SUPPLIER DRAWING DECAL
ProjectID
Alternative Document No.
1- Accepted (Reviewed andAgreed)
2- Comments to be Incorporatedand Resubmitted
Signature Date
3- Rejected, Do Not Start Work(Comments to beIncorporated andresubmitted)
4- For Information
Review Status
Short RequisitionNo/PO Identifier
Sequence Sheet. Rev
5- Cancelled/Superseded
6- As Built
Purchaser Document Number
Originator/ContractorCode
SDDRCode
CLB- AA- AANNNN-ANN ANN- NNNN- (NN) NN
DRAWING TO BE READ IN CONJUNCTION WITH SHEET 1
B ALLUPDATED INLINE WITH COMMENTS
BY AMEC ON 8/8/13.UPDATED TO SHOW LOUVERS WHICHGIVE THE CORRECT VENTILATION TOTHE TRANSFORMER (POST CALCS.)
06.09.13
C 6E'LANDING AREA' WARNING SIGN ADDED
TO INSIDE OF DOOR 19.11.13
D 5E LIGHTING & SMALL POWER DIST. BOARD
(WAS ITEM 26) REMOVED INLINEWITH CUSTOMER COMMENTS
DATED 22/1/14
03.02.14