    THIS DOCUMENT

    This document is a review guide to changesproposed in the Centers & Corridors DesignStandards in SMC 17C.122.060

    Spokane Municipal Code 17C.122 is the primaryland use code section for Centers & Corridorszoning review of that section is important tounderstanding the guidelines

    Spokane C ity Code is on line atspokanecity.org/smc

    2

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    3/25

    SPOKANE MUNICIPAL CODE17C.122 CENTERS & CORRIDORS CODE

    Design Guidelines apply to CC1, CC2, and CC3overlay and CC4 (described in SMC 17C.122.060)

    CC1 promotes the greatest pedestrian orientation of thecenter and corridor zones.

    CC2 promotes pedestrian oriented while accommodatingthe automobile.

    CC3 is an overlay which allows voluntary use of CC1 or CC2

    CC4 is a multiuse transition zone. It is designed to bepredominately residential in character.

    Pedestrian Streets special designation on zoningmap

    3

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    4/25

    DESIGN GUIDELINES AREATTACHMENT OF SMC 17C.122.060

    The balance of SMC 17C.122 Centers and Corridorsgoverns development in these zones.

    There are additional development standardsthroughout the development code that wouldapply to development

    Additional code sections amended: Landscaping and Screening Chapter,

    17C.200.040

    Design Departures, Purpose, SMC 17G.30.010

    4

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    5/25

    WHY AMEND GUIDELINES?

    Guidelines adopted 2005 not amendedsince then.

    Walkable commercial and high densityresidential centers desired.

    City Council and Community led process

    Some projects have been built that did notmeet communitys expectations

    5

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    6/25

    STAKEHOLDERS CONSULTED

    Council Member Amber Waldref

    Council Member Candace Mumm

    Architects: Dana Harbaugh, Gary Bernardo, Chris Olsen,

    Ann Martin, Craig Conrad, Craig Woodard, Evan Verduin Community Members: Paul Kropp, Teresa Kafensis, TedTeske, Kerry Brooks, Karen Byrd, J ennifer Day, WhitneyWelch, E.J . Iannelli, Kitty Klitzke

    Developers/Builders: J im Frank, J ason Wheaton, Ron Wells Real Estate: Cory Barbieri, Ron Wright, Guy Byrd

    Planner/Landscape Architect: Len Zickler

    Community Assembly members6

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    7/25

    MAJOR CHANGES PROPOSED

    Should to Shall changes

    Required built to street percentage established

    Prominent Entry on corner lots required

    Clarification of Drive-through Lane language

    Increasing the width of perimeter landscape buffer betweenCC & Residential Zoned lots amending SMC 17C.200.040Landscape Chapter

    Adding and limiting the instances in which designdeviations may be requested shifts this to Design ReviewBoard recommendation to the Director

    7See Change Matrix for complete review

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    8/25

    SHOULD vs. SHALL

    8

    Changes proposed in Guidelines Application section

    Should Guidelines with should are meant to be applied, butwith some flexibility.should indicated that the City is open

    to design features that are equal to, or better than, that stated solong as the intent is satisfied. Director decision.

    Shall statements - mandatory and offer little flexibility unlesschoices are provided within the statement itself. Design

    Deviations are permitted by the Planning Director only afterreview and recommendation by the Design Review Board.

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    9/25

    DESIGN DEVIATION

    This concept exists in the City Code 17G.030. Itsadded to the Design Guidelines in the draft.

    When an applicant may ask for Design Deviation: Transition between Commercial and Residential

    Development

    Massing

    Roof Form

    No design deviation language in: Buildings along Street

    Historic Context Considerations

    9

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    10/25

    BUILDINGS ALONG STREET (page 4)

    No Design Deviation permitted

    Should to Shall with no provision for Design Deviation

    Buildings Along Street

    Currently code says no parking lot between building and street

    Only place where a percentage build to street is currentlyrequired is in Shopping Centers. (15%)

    Draft strikes in shopping centers

    Change proposed:

    Require 50% of the frontage of the site consists of building facades

    Change proposed:

    Buildings shall be placed to the corner

    10

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    11/25

    LANDSCAPE BUFFER(CHANGE IN SMC 17C.200.040B)

    Proposal is to amend the perimeter landscaperequirements in 17C.200.040(B)

    This would change the size of the landscape buffer which isalready required between CC and RA, RSF, RTF, RMF, andRHD zoned adjacent properties to be 8 rather than 5 feet

    Proposal to change CC to RHD from L2 landscaping to L1landscaping (this is already required in other residentialzones)

    L1 is defined as (see SMC 17C.200.030):

    11

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    12/25

    SIDEWALK ENCROACHMENTS

    Change from 4 to 6 feet matches existing c itystandards

    Clear walking path for pedestrians and ADA

    12

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    13/25

    LIGHTING (PAGE 6)

    Adds requirement to provide lighting along publicsidewalks

    13

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    14/25

    SCREENING SERVICE AREAS (PAGE 7)

    Adds language that loading areas should not...beadjacent to any residential

    Leaves this as a should statement since may be

    difficult to achieve

    14

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    15/25

    PEDESTRIAN CONNECTIONS INPARKING LOTS (PAGE 10)

    Minor addition adds primary:

    15

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    16/25

    DRIVE THROUGH LANES (PAGE 11)

    16

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    17/25

    TRANSITION BETWEEN COMMERCIALAND RESIDENTIAL DEVELOPMENT (PAGE 12)

    Adding 3 instead of 2 architectural treatments beused.

    Possibly adding more architectural treatments:

    Adding Design Deviation -- requires arecommendation of approval by the Design ReviewBoard

    17

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    18/25

    PROMINENT ENTRANCES (PAGE 13)

    Restates build to corner from Section Buildingsalong street

    18

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    19/25

    MASSING (PAGE 16)

    Change should to shall for both guidelines

    Adds language that there should be articulation

    Design Deviation from Guidelines #1 & #2 go to DRB

    19

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    20/25

    ROOF FORM (PAGE 17)

    No substantive changes to guidelines

    Adds the Design Deviation must be sought from DRBlanguage

    20

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    21/25

    HISTORIC CONTEXT CONSIDERATIONS(PAGE 18)

    21

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    22/25

    PEDESTRIAN STREETS:DESIGN STANDARDS (PAGE 20-25)

    No amendments proposed

    22

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    23/25

    SUPPLEMENTAL STANDARDS FOR CC1(PAGE 26 TO PAGE 30)

    No amendments proposed

    23

  • 8/9/2019 Summary Centers Corridors Design Guidelines

    24/25

    HOW DOES THIS COMPARE TORECENT LOGAN CODE REVISIONS?

    Build to street requirements are in this new code. 80% building frontage to the street on a Type 1 Street

    (Hamilton)

    60% building frontage on Type 2 Street (Mission)

    Build to corner requirements are also in this code

    Logan Form Based Code was approved by City

    Council on J an 12, 2015.To view the Logan Code go to:

    https://beta.spokanecity.org/projects/logan/

    24

    https://beta.spokanecity.org/projects/logan/https://beta.spokanecity.org/projects/logan/https://beta.spokanecity.org/projects/logan/
  • 8/9/2019 Summary Centers Corridors Design Guidelines

    25/25

    FOR MORE INFORMATION

    www.spokanecity.org, Business & Development,Projects, C itywide Initiatives

    Tirrell Black, Assistant Planner,[email protected]

    Please contact Tirrell Black if youd like to be on amailing list for further action on this item.

    Council Member Amber Waldref, 509-625-6255

    [email protected]

    25