20
Subsurface Investigation Building structure system

Subsurface Investigation Building structure system

Embed Size (px)

Citation preview

Page 1: Subsurface Investigation Building structure system

Subsurface Investigation

Building structure system

Page 2: Subsurface Investigation Building structure system
Page 3: Subsurface Investigation Building structure system
Page 4: Subsurface Investigation Building structure system

FIELD TESTING

Page 5: Subsurface Investigation Building structure system

ºÉ°� ª· µ¦� � µ¦ Á Ê ·� � � � � � � �

Á¨É¥ ¨ ³Áµ³� � � � � � � µ¦� � �¥oµ¥

nµÄonµ¥� � � »£µ¡ °� � � �®»¤Áµ³�

o° ε ´� � � � µ¦Á· n°� � � � °� � �

»Á· n° oª¥� � � � � �¦ ®¦º°� � �Á¦ºÉ° ¦� � � �

¦ª ° ¤ Åo� � � � �Ã¥ ¦ ³ ´ ¹®¦º°� � � � � � �nµ¥£µ¡ µ¦Á¦¥ ª °� � � � � �Ê ·Åo°¥nµ Á� � � � � � � � � �

³ ª� � µ� �µ� �

¤µ� � ªµ¤ ¹¤ Ťn� � �Á·� � 2-3 Á¤ ¦�

µ¦Áµ³� � ªnµ�

Äoµ¦®¤»Ä� � � � ªnµÁ¡ºÉ° ε ·� � � �¹Ê¤µ� �

¤ ε ÅoÃ¥ ¦� � � � � � � �µ · É· ¹Ê¤µ´Ä� � � � � � � � � � � �

ªnµ� (Ä®»¤Áµ³Â®o� � � )

³ ª� �(°» ¦ r� � �¤ Îʵ®´� � �Ťn¤µ� )

Ťn ¼� ¸� (Á¤ºÉ°ÁÈ®»¤� �Áµ³Â®o°¥¼n� �Á®º°¦³ ´ Îʵ� � � �Äo·� � � )

¤ ¤°» ¦¦ Ä� � � �µ¦Áµ³ nµ Ê� � � � � �¦µ¥� - ¦ª ®¦º°� �µ¦Áµ³°¥¼nÉ� � �

¦³ ´ Îɵªnµ� � � �¦³ ´ ÎʵÄo·� � � � � �

µ¦Áµ³� �¨oµ�

ÄoÎʵ ¸ oµ ³� � � � � � �¥ ®ªÁµ³� �¦³Â ¹Ê� � � � � - �

¡¦o°¤ ´ · oµ� � � � � �Áµ³�

Á µ ° Îʵo É� � � � � � � � � �¹Ê¤µµ®»¤Â³Äo� � � � �µ¦ ¤ µ oµÁµ³� � � � � � �

¦ª¤ Ê° ¦µ ° ®ª� � � � � �Áµ³�

³ ª� �µ� �µ� �

(°» ¦ r� � �Ťn´ o°� � � �

¤µ� )

Ťn ¼¤µ� � ¡°Äo�(ÁºÉ° µ ·� � � � � �µ nª ¼� � � � �

¦ ª� � � )

Ťn µ¤µ¦ Áµ³� �nµ Ê ¦ª� � � � � �

Ä®n¼¦ ÂÈ� � � � �®· »®¦º° µ� � � �

� µ¦Á� µ³� É� Ä� oÁ� ¦ºÉ°� ®¤»� � É�³ É ®ªÁµ³� � � � � �

¨ ¡¦o°¤ ´ÄoÎʵ� � � � �°° µ¦¼� � � � �

oµ oµ®ªÁµ³� � � � �

Á µ ° Îʵ Éo� � � � � � � � � �¹Ê¤µµ®»¤Â³� � � �

Á µÂ¦ ¦ª¤ Ê� � � � � � � � � �° ¦µ ° ®ªÁµ³� � � � �

¥»n¥µ� �(°» ¦ r� � �¤ Îʵ®´� � �¤µÂ³�´ o°� � � � )

¼� ¤µ� � (®»¤Áµ³ ³°µÂ³� �· ¼¦ ª� � � � � � �o°¥� )

ÄoÅo Ê ·� � � � � � � �³ Ê®· »� � � � �

·� � �

Page 6: Subsurface Investigation Building structure system

Soil Boring Machine

• Flight Auger system

• Wash Boring

Page 7: Subsurface Investigation Building structure system

Rotary Drilling

•Undisturbed

•Machine Require

Page 8: Subsurface Investigation Building structure system

Wash Boring

•Rotary Drilling

•Percussion Drilling

Page 9: Subsurface Investigation Building structure system

Sampling

Thin wall (Shelby tube)

Split Sampler

Page 10: Subsurface Investigation Building structure system

PHYSICAL PROPERTIES ATTERBERG LIMITS ENGINEERING PROPERTIES

Wn g LL PL PI Su Su from Ncor N Ncor

From To % t/m3 #4 #200 % % % t/m2 t/m2 blows/ft blows/ft

1.50 2.00 31.17

3.00 3.50 33.32 1.83 37.00 15.69 21.31 CL 3.88

4.50 5.00 41.71

6.00 6.50 59.40 1.67 63.60 27.52 36.08 CH 0.37

7.50 8.00 80.10

9.00 9.50 76.08 1.53 88.00 36.78 51.22 CH 0.13

10.50 11.00 57.31

12.00 12.50 68.26

13.50 14.00 63.05 79.40 33.28 46.12 CH 0.50

15.00 15.50 24.12

16.50 16.95 26.90 1.98 14.70 33 24

18.00 18.45 27.62 1.83 83.20 26.18 57.02 CH 15.31 35 25

19.50 19.95 26.96 1.85 16.53 39 27

21.00 21.45 19.15 2.21 100.00 76.01 35.80 17.21 18.59 CL 13.17 28 22

22.50 22.95 19.14 1.95 18.38 45 30

24.00 24.45 20.08 1.88 20.51 52 34

25.50 25.95 21.30 1.91 100.00 60.11 31.20 18.80 12.40 CL 14.70 33 24

27.00 27.45 17.59 82 48

28.50 28.95 24.57 100.00 30.17 SM 100 58

30.00 30.45 24.28 180 98

31.50 31.95 25.94 1.97 68.10 22.31 45.79 CH 20.21 51 33

33.00 33.45 26.14 1.86 15.92 37 26

34.50 34.95 23.21 1.95 15.00 34 25

36.00 36.45 20.79 2.08 59.20 14.47 44.73 CH 32.00 90 53

37.50 37.95 18.58 2.00 29.32 81 48

39.00 39.45 23.92 2.20 100.00 68.43 38.60 16.10 22.50 CL 32.15 90 53

40.50 40.95 16.56 2.02 27.50 75 45

42.00 42.45 20.13 2.00 100.00 91.55 46.40 9.46 36.94 CL 22.97 60 38

43.50 43.95 13.85 100.00 51.38 25.30 14.96 10.34 CL 86.26 267 141

45.00 45.45 26.57 2.04 37.67 108 62

46.50 46.95 23.05 2.29 45.42 133 74

48.00 48.45 27.83 1.87 77.60 31.36 46.24 CH 14.09 31 23

49.50 49.95 35.75 1.82 12.56 26 21

51.00 51.45 24.34 75 45

52.50 52.95 20.25 100.00 27.45 SM 113 64

54.00 54.45 21.93 63 39

55.50 55.95 24.44 100 58

57.00 57.45 23.70 100.00 25.11 SM 150 83

58.50 58.95 19.00 240 128

60.00 60.45 15.45 100.00 25.30 SM 200 108

ST-03

ST-04

ST-05

ST-06

Sample No.

Depth, m Soil Class.

% passing

ST-02

ST-07

ST-08

ST-09

ST-10

ST-01

SS-15

SS-16

SS-17

SS-18

SS-11

SS-12

SS-13

SS-14

SS-23

SS-24

SS-25

SS-26

SS-19

SS-20

SS-21

SS-22

SS-31

SS-32

SS-33

SS-34

SS-27

SS-28

SS-29

SS-30

SS-35

SS-36

SS-37

SS-38

SS-39

SS-40

Page 11: Subsurface Investigation Building structure system

Standard Penetration test

Page 12: Subsurface Investigation Building structure system

Field TestingStandard Penetration Test (SPT)

ASTM D1586 –140 lb (63.5 kg)- Falling 30 inches (0.76 cm)

Test in 3 interval @ 150 mm

Use only the 2 last 2 interval =150x2 =300 mm = 1 ft

The unit is Blow per foot

Page 13: Subsurface Investigation Building structure system

Interpretation

•Classify soil to be clay or sand• C for clay• f for sand•Calcuate the strength parameter

-Correction for SPT-Calculate the strength parameter

Page 14: Subsurface Investigation Building structure system

Strength parameter for sand (Peck’s Approach)15 0.5( 15)corrected measuredN N

35

•No effective stress calculation•Empirically correlation

Page 15: Subsurface Investigation Building structure system

Parry (1977)

Adjustment with overburden pressure

Page 16: Subsurface Investigation Building structure system

60 1 N 60(N ) C N

0.5

N '0

a

1C

p

N '0

a

2C

1p

Correction for N-value according overburden pressure

Page 17: Subsurface Investigation Building structure system

Correlation qu vs N (Sambhandharaksa, 1985)

Page 18: Subsurface Investigation Building structure system

Strength parameter for clay

corc 6N (kPa)

15 0.5( 15)corrected measuredN N

Procedure for classify soil

•Start with water content and unit weight•Check strength parameter with index properties•Divide soil layer

Page 19: Subsurface Investigation Building structure system

¦³Á£ ·� � � � ·ÁºÉ°¤Ân� � � � � (Cohesive Soil) ·Å¤nÁºÉ°¤Ân� � � � � (Cohesionless Soil)

SPT N-value Consistency UC-test (kPa) SPT N-value Consistency Dr (%) 0-2 Very Soft 0-25 0-5 Very Loose 0-5 2-5 Soft 25-50 5-10 Loose 5-30 5-10 Medium 50-100 10-30 Medium 30-60 10-20 Stiff 100-200 30-50 Dense 60-95 20-30 Very Stiff 200-400 >30 Hard >400

Page 20: Subsurface Investigation Building structure system

Soil Boring

•Number of Boring•Depth of boring

ThailandDepth of Boring is 30 or 60 m.