Heat pumps - Inertial puffers - Indirect cylinders - Water Heaters
Citation preview
Italian technology and quality
GENERAL CATALOGUE
Heat pumps - Inertial puffers - Indirect cylinders - Water Heaters
Heat pumps 4> wall-hung series 80-100 5
> floor standing series 180-300 6
> floor standing with coil series 300 8
> accessories & kit for heat pump 10
Inox 11> wall-mount electric water-heaters rapid series 10 12
> vertical wall-mount electric water heaters series 65 13
> vertical wall-mount electric water heaters series 50-80-100 13
> floor standing electric water heaters series 120-160-200-300-400-500 14
> floor standing electric water-heaters high storage series 800-1000 15
> indirect cylinders single and double coil series 120-160-200-300-400-500 16
> indirect cylinders single and double coil high storage series 800-1000 18
> accessories & kit for inox 20
Indirect cylinders 21> circular undermount series 115-150 22
> rectangular undermount series 120-160 23
> elliptical increased size coil series 300-400-500 24
> single and double coil series 120-160-200-300-400-500-600 26
> single and double coil high storage series 800-1000 28
> multiposition series 80-100-115-150-200-300 30
> accessories & kit for indirect cylinder 31
Inertial puffers 33> puffer series 200-300-400-500-600-800-1000 34
> tank in tank series 600-750-900 36
Contents
2
Contents
Gas water heater 39> wall-hung natural draught series 50-80-100-120 40
> wall-hung Fan flue series 80-120 41
> floor standing natural draught small storage series 115-150-200 42
> floor standing natural draught medium storage series 300-500 43
> floor standing natural draught high storage series 600-800-1000-1500-2000 44
> floor standing fan flue series 220-300-400 45
> accessories & kit for gas water heaters 46
Electric water heaters 47> wall-hung rapid series 10-15-30 48
> wall-hung round series 30 49
> wall-hung mini vertical series 30 49
> wall-hung vertical series 50-80-100 50
> wall-hung high storage series 120-150-200 52
> wall-hung thermoelectric series 50-80-100 53
> wall-hung thermoelectric high storage series 120-150-200 54
> wall-hung thermoelectric with increased size coil series 60-80-100-120-150-200 55
> wall-hung horizontal series 50-80-100 56
> wall-hung horizontal high storage series 120-150-200 56
> wall-hung horizontal thermoelectric series 80-100 57
> floor standing series 120-160-200-300-400-500-600 58
> floor standing high storage series 800-1000 59
> accessories & kit for electric water heaters 60
Wood-fired water heaters 61> floor standing series 80 62
3
The SystemThe heart of the “System” is an indirect cylinder with a built-in heat pump that enables the simultaneous or selective use of up to four different energy sources:1) thermal energy;2) electricity;3) solar power;4) environmental energy.The heat pump is designed to transfer heat from a body at a lower temperature to another body at a higher temperature. This process is the opposite of what happens in nature, and is due to the fact that electricity is supplied to the appliance that “heat pumps”.The operating principle of the heat pump is a thermodynamic cycle opposite to refrigeration. The efficiency of a heat pump is represented by its performance coefficient COP, which is the ratio of the heat output yielded to the electrical power utilised.
Operating principleThe heat pump comprises a closed circuit made up of a compressor, a condenser, a lamina-tion valve and an evaporator through which the heat transfer fluid flows. The thermodynamic cycle the fluid experiences consists in an adiabatic compression, a condensation phase, an expansion phase and also evaporation. During compression, the pressure and temperature of the fluid rise, during the second stage the fluid flows through a heat exchanger (condenser) where it comes into contact with domestic water, to which it yields heat. During the third stage, the fluid flows through an expansion valve (lamination process) and its pressure and temperature consequently drop. During the last stage, referred to as evapo-ration, the fluid switches from its liquid state to gas: the coolant is at very low temperatures, which enable it to absorb heat from the external heat transfer fluid. So during the operation of the heat pump, the following occurs: electricity is consumed in the compressor, heat is absor-bed from the external environment (evaporator) and heat is yielded in the condenser to the liquid that needs to be heated. The advantage of a heat pump lies in the fact that more energy is supplied in the form of heat than the electricity required for its operation.
The strengthsThe features that make this system worthwhi-le are multiple, but the most obvious advan-tage is that it is an intrinsically efficient system. It has direct repercussions on the amortisation of the installation cost and on the consumer’s utility bills too. Moreover, using a heat pump enables the exploitation of portions of energy which would otherwise be wasted (such as in installations in boiler rooms). Lastly, this system also provides an easy and convenient integration with other renewable energy sources (solar panels, wo-od-fired boilers, etc.). Heat pumps are ideally installed in cellars or damp rooms because the humidity in the air is removed during operation (dehumidifying effect).
EVAPORATORAbsorption of heat
from the outside
2/3 of energy
CONDENSERYielding of heat
to the domestic water
3/3 of energy
LAMINATION VALVE
ELECTRICITY SUPPLY
1/3 of energyEvaporator
Honeycomb grid
EBM axial fan
Support and drip water basin
Control panel
FilterThermostat-
controlled valveDanfoss
Compressor
4
Heat pumps
WWKW
B20
660
544
A
470�
100
431
112
480
FuturaSERIES 80-100
Compact system for heating sanitary water by using an air-to-water heat pump. The system utilises renewable energy. It is one of the most interesting products to be used for decreasing the fuel consumption and protecting the environment. Thanks to its small dimensions, equal to a normal water heater, and to its easy installation, the new heat pump (from 80L to 120L) is intended for domestic use. Just plug it in, like a normal water heater, and it is ready.
• Steel tank, glass-lined using the flow-coating method (850 °C).
• Corrosion-proof magnesium anode.• External casing made of sheet metal
coated with (white) epoxy powder paint.
• CFC and HCFC-free, 37 mm average polyurethane (PU) foam insulation layer.
• Hydraulic connections located in the lower part.
• Brackets for wall-mounting.
• 1,2 kW integrated electric heating element.
• Electronic control panel with display indicating temperature, indicator light for heat pump operation and electric resistance. Switch to activate the different modes of operation: Turbo, Bath, Comfort.
• Ecological refrigerant fluid R134a;• Rotary compressor for maximum
noiseless• Axial fan• Powerful fin type evaporator.
Capacity Power supply Refrigerant fluid/ average load
Average absorption (Heat pump only)
Electric heating element (water)
Electric heating element (air heating)
Maximum nominal absorption
V~/Hz/A -/kg kW kW kW kW230/50/16 R134a/0,28 0,31 1,20 0,90 2,41
230/50/16 R134a/0,28 0,31 1,20 0,90 2,41
Maximum temperature (heat pump only)
Maximum temperature (with electric heating element)
Maximum operating pressure
Net weight
Hydraulic connections A B
°C °C MPa kg KW-WW mm mm56 65 0,80 50 R 1/2 1142 392
56 65 0,80 56 R 1/2 1355 605
Series 80-100Heat PumP
newnew
Same connections of traditional water heaters
Easy installation
Canalization and masonry work not required
Save up to 70% of electricity
5
Capacity
lFutura ST 080 80
Futura ST 100 100
Futura ST 080Futura ST 100
wall-hung HeaT pump
Heat pumpsSERIES 180-300
Domestic water heating system with air-water heat pump. The system envisages the use of renewable energy and the possible integration with other energy sources such as electricity. Recommended for domestic and collective use.
• Steeltank,glass-linedusingtheflow-coating method (850 °C).
• Ø134mmfrontinspectionhatchintegrated with tinned copper condenser.
• Corrosion-proofmagnesiumanode.• Hydraulicconnectionslocated
on the rear.• CFCandHCFC-freeverythick
polyurethane (PU) foam insulation layer.
• Externalplastic(PVC)coating.• Adjustablefeetforfloorstanding.
• Environmentally-friendlygasR134a.• 1.5kW230V~electricheatingelement.• Controlpanelcompletewithswitch
with indicator light for heat pump and heating element operation, regulation thermostat, thermometer and signal indicators.
• Highandlowpressuresafetydevices.• DANFOSScompressorforsupersilent
operation.• EBM650m3/h axial fan.
Accessories on page 10
Capacity Power supply
Coolant/ average recharge
Absorption (heat pump only)*
Max. nominal absorption
Power output (heat pump only)*
Electric heating elem ent (integration)
l V~/Hz/A -/kg kW kW kW kW230/50/16 R134a/0,85 0,62 2,12 1,91 1,50
230/50/16 R134a/0,85 0,62 2,12 1,98 1,50
Maximum power output
Range of hot water temp. setting
Range of use
Maximum noise level
Max.temperature (heat pump only)
Max.temperature (with electric heating element)
Max. operating pressure
Net weight
Hydraulic fittings
Recirculation fittings
kW °C °C dB (A) °C °C MPa kg KW-WW Z3,41 29÷56 8÷35 61 55 65 1,0 95 Rp 1 Rp 1
3,48 29÷56 8÷35 61 55 65 1,0 109 Rp 1 Rp 1
Note: ** primary circuit temperature 80°C / secondary circuit temp. 10/45 °C
Data compliant with eN 255-3 (WpZ B-002-04-07 Wärmepumpentestzentrum NTB - FWS CH-Buchs)*
Coefficientof performance
Max. qty individual flow rate at 40 °C V max
Max. actual powerabsorbed Pes
Heating time th C D E F
COPt
I W h:min mm mm mm mm3,1 283 36 4:56 1412 142 612 9223,2 448 44 7:57 1852 142 912 1362
Note: * Room air temp. 15°C, humidity 71%, domestic water at 15° C / temperature in storage tank 55° C
Series 180-300Heat PumPs
6
Capacity
Hp 180 180
Hp 300 300
Hp 180Hp 300
Hp 180Hp 300
HeaT pumpstand alone
Z
D
E
F
713
C
650
WW
KW
Z
D
E
F
713
C
650
WW
KW
7
HeaT pump
Heat pumpsSERIES 300
Domestic water heating system with air-water heat pump. The system envisa-ges the use of renewable energy and the possible integration with other ener-gy sources such as electricity, thermal energy and solar power. Recommended for domestic and collective use.
• Steeltank,glass-linedusing the flow-coating method (850 °C).
• Ø134mmfrontinspection hatch integrated with tinned copper condenser.
• Singlecoil(forWversion)and double coil (for WW version), optimised for maximum heat exchange and minimum limescale build-up.
• Sensorfittings, (one for W version) (two for WW version).
• Corrosion-proofmagnesium anode.
• Hydraulicconnectionslocated on the rear.
• CFCandHCFC-freeverythick polyurethane (PU) foam insulation layer.
• Externalplastic(PVC)coating.
• Adjustablefeetforfloorstanding.
• Environmentally-friendlygas R 134a.
• 1.5kW230V~electricheating element.
• Controlpanelcompletewith switch with indicator light for heat pump and heating element operation, regulation thermostat, thermometer and signal indicators.
• Highandlowpressuresafety devices.
• DANFOSScompressorfor super silent operation.
• EBM650m3/haxialfan.
Accessories on page 10
Power supply
Coolant/average recharge
Absorption (heat pump only)*
Max. nominal absorption
Power output (heat pump only)*
Electric heating element (integration)
Maximum power output
Range of hot water temp. setting
Range of use
V~/Hz/A -/kg kW kW kW kW kW °C °C230/50/16 R134a/0,85 0,62 2,12 1,91 1,50 3,41 29÷56 8÷35
230/50/16 R134a/0,85 0,62 2,12 1,91 1,50 3,41 29÷57 8÷35
Data compliant with eN 255-3 (WpZ B-002-04-07 Wärmepumpentestzentrum NTB - FWS CH-Buchs)*
Coefficientof performance
Max. qty individual flow rate at 40 °C V max
Max. actual powerabsorbed Pes
Heating time th C D E F
COPt
I W h:min mm mm mm mm3,2 430 43 7:51 See diagram
3,1 430 55 8:01 See diagram
Note: * room air temp. 15 °C, 71% humidity, domestic water at 15 °C / temperature in storage tank 55 °C
Maximum noise level
top/bot. coil surface
Heat output (∆T 35 K)** top/bot.
Primary flow rate
Max. temperature (heat pump only)
Max. temperature (with electric heating element)
Max. operating pressure
Net weight
Hydraulic fittings
Exchanger fittings
Recirculation fittings
Number of sensors
dB (A) m² kW m³/h °C °C MPa kg KW-WW PV-PR Z Tr61 1,30/- 37/- 2,50 55 65 1,0 130 Rp 1 Rp 1 Rp 1 1
61 1,30/0,80 37/26 2,50 55 65 1,0 145 Rp 1 Rp 1 Rp 1 2
Note: * primary circuit temperature 80 °C / secondary circuit temp. 10 /45 °C.
1-2 Coil
8
Capacity
l
Hp 300 W 300
Hp 300 WW 300
Hp 300 WHp 300 WW
Hp 300 WHp 300 WW
HeaT pumpfixed single and double coil
KW
Z
WW
PV
PR Tr Tr
14230
284
2108613
62
65018
52713
Tr
Tr
Tr
Tr
WW
Z
PV2
PV1PR2
PR1KW
14230
284
2960
108612
121362
650
1852
713
KW
Z
WW
PV
PR Tr Tr
14230
284
2108613
62
650
1852
713
300 WW
300 W 300 W
300 WW
9
HeaT pump
accessories & kit for heat pumps
CODE DESCRIPTION
145053 AIR DELIVERY KIT The kit includes: black PST air conveyor, conveyor fastening system, aluminium rings
forØ160mmpipefastening,instructions,package.
145066 AIR SUCTION KIT The kit includes: black PST air conveyor, conveyor fastening system,
aluminiumringsforØ160mmpipefastening,instructions,package.
KIT diagram
Suction Delivery
Suction KIT Delivery KIT
1 0
HeaT pump
The “STReNGTHS” of the product range in detail:
1 1
Thanks to its range including electric storage water heaters and stainless steel indirect cylinders, STYLEBOILER offers complete solutions for the pro-duction of hot water with a capacity included between 10 and 1000 litres and powers included between 1.2 and 10 kW with single and three-phase connections.The range meets the domestic needs, but it can also be suitable for commu-nal settings. The product lines range from the “small” line, which is ideal for producing small quantities of water in a rapid and cheap way, to the “easy” medium-size water heaters, up to the “extra” line, which supplies the most advanced technology to be found on the market.“Interline” and “Free Standing” lines are the best way to meet the needs of huge quantities of hot domestic water and also meet the highest quality ex-pectations in compliance with European and international standards.
InoxThe “inox” (stainless steel) product line has been created to meet the new expectations as to durability and perfection. This line provides maximum quality and durability owing to the use of special materials such as stainless steel and sophisticated technologi-cal solutions, such as “TIG” and “Microplasma” welding.
Thermal insulation layerIt is manufactured with very thick and high-density polyurethane foam (PU) (Interline range) to assure excellent thermal insulation.
Magnesium anodeIt is to be found in all products within the range and makes the boiler’s electrochemical protection constantly effective.
Correx® corrosion-proof active protectionThe Correx® system is the latest technology in terms of active tank protection, and is fitted with a PCB, a control LED and a transmitted current titanium anode. This system solves all your anode-replacement and limescale removal problems.
Double safetyIt is achieved by using an operation thermo-stat and an over-temperature thermostat to prevent possible malfunctions.
IP protection levelStyleboiler’s water heaters are safe because theystandwaterjetsandcanbeinstalledclo-se to the supply points, also in public spaces and communities.
Respect of the environmentStyleboiler undertakes streamlining the in-dustrial activities in the respect of the envi-ronment. In order to reduce the environmen-tal impact to the minimum, it eliminated the hydrofluorocarbons (CFC-HCFC) from the insulation (PU) layer and always pays great attention to the recyclability of the compo-nents.
Line Inox
WWWK
100
450
261
228
251
62189
W WK W
100
261
450
250
251
62189
• AISI316Lstainlesssteelboiler,welded with “TIG” and “Microplasma” technology.
• AISI321stainlesssteelheatingelement.
• Corrosion-proofmagnesiumanode.• Stemsafetyandadjustment
thermostat. • Insulationlayerwithpolystyrene(EPS)
shells to minimise heat loss.
• Shellandbackmadewithshock-resistant polypropylene (PP).
• Wall-mountbyusingthespecificbrackets.
• Indicatorlight.• IPX5protectivecoverover
electrical parts.• Nylondielectriccircuitbreakers
on the hydraulic fittings.
Wall-mounted electric storage water heaters are designed for producing small quantities of water in a rapid and cheap way, as well as to meet the new ex-pectations as to durability and perfection. The “inox” stainless steel product line has been created for this purpose; this line supplies maximum quality and durability thanks to the use of special ma-terials, such as stainless steel and sophisticated technological solutions, such as “TIG” and “Microplasma” welding.They can be installed above and under the sink.
oversink version 10 undersink version 10
Capacity Power Voltage Heat. time Δt=50°CMax. oper.
temp.Max. oper.
press.Net
Weight Hydraulic
fittings
l kW V~ min °C MPa kg KW-WW
1,2 230 30 75 0,8 4,6 R ½
1,2 230 30 75 0,8 4,6 R ½
Note: s = undersink version. .
1 2
Capacity
l
pony 10X 10
pony 10X s 10
Small inoxSERIES 10
eLeCTRIC WaTeR HeaTeRSstorage-type, wall-mount above and under the sink
WWKW
450
648
100
424
072
211
475
WWKW
450648
100
424
072
211
475
054 574
B
A
001 211
072
WWKW
054 574
B
A
001 211
072
WWKW
Stainless steel wall-hung electric storage water heaters are designed to meet the new expec-tations as to durability and perfection. To this end, the “inox” (stainless steel) product line was introduced, providing maximum quality and durability owing to the use of special materials such as stainless steel and sophisticated technological solutions such as “TIG” and “Mi-croplasma” welding.
The wall-mounted electric storage wa-ter heater represents the basic range that combines great functionality, high efficiency and maximum quality.
• Aisi316Lstainlesssteeltankweldedwith“TIG” and “Microplasma” technology.
• Tankinspectionflange.• “Correx®”electronicprotectiondevice
with titanium anode and signalling LED.• Incoloy800stainlesssteelheating
element fitted on a flange.• Externalregulationandsafetycapillary
thermostat.• LEDindicatorlight.• CFCandHCFC-freeverythickpolyurethane(PU)
foam insulation layer.• Externalcasingmadeofsheetmetalcoated
with epoxy powder paint.• IPX5protectivecoveroverelectricalparts
complete with cable and plug.• Storedwatertemperatureindicator.• Nylondielectriccircuitbreakersonthehydraulic
fittings.
• AISI316Lstainlesssteelboiler, welded with “TIG” and “Microplasma” technology.
• Corrosion-proofmagnesiumanode.• AISI321stainlesssteelthreadedheating
element on 1” sleeve.• Capillarysafetyandinternalregulation
thermostat.• Indicatorlight.• CFCandHCFC-free,verythickexpanded
polyurethane (PU) insulation layer.• Externalcasingmadeofsheetmetalcoated
with epoxy powder paint.• IPX5protectivecoveroverelectricalparts.• Storedwatertemperatureindicator.• Nylondielectriccircuitbreakersonthe
hydraulic fittings.
Power Voltage Heat. time Δt=50°C
Max. oper. temp.
Max. oper. press.
Net Weight
Hydraulic fittings
kW V~ min °C MPa kg KW-WW
1,2 230 198 75 0,8 15,50 R ½
Power Voltage Heat. time
Δt=50°CInsul.
ThicknessHeat loss
65°CMax. oper. temp.
Max. oper. press.
Net Weight
Hydraulic fittings A B
kW V~ min mm kWh/24h °C MPa kg KW-WW mm mm
1,5 230 123 ≥25 0,87 75 0,8 14,0 R ½ 596 375
1,5 230 196 ≥25 1,13 75 0,8 18,5 R ½ 799 587
1,5 230 245 ≥25 1,30 75 0,8 23,5 R ½ 1013 801
1 3
Capacity
l
SSWVX65 65
Capacity
l
ISWVX 50 50
ISWVX 80 80
ISWVX 100 100
Easy inoxSERIES 65
eXtra inoxSERIES 50-80-100
eLeCTRIC WaTeR HeaTeRS storage type, wall-mounted
Z
DE
F
A
C
B
WW
KW
Stainless steel floor-standing electric storage water heaters are designed to meet the new expectations as to durability and perfection. To this end, the “inox” (stainless steel) product line was introduced, providing maximum qua-lity and durability owing to the use of special materials such as stainless steel and sophisticated technological solutions such as “TIG” and “Plasma” welding. The insulation layer is made of very thick high-density polyurethane (PU) foam to minimise heat loss. They are ideal for collective and industrial use.
• Aisi316Lstainlesssteeltankweldedwith “TIG” and “Plasma” technology.
• Ø134mmfrontinspectionhatch.• Ø134mmflangeonthetopofthe
tank complete with counter flange.• “Correx®”electronicprotection
device with titanium anode and signalling LED.
• Three-partincoloy800stainlesssteel heating element.
• Regulationandsafetycapillarythermostat.
• CFCandHCFC-freeverythickpolyurethane (PU) foam insulation layer.
• Externalcolouredplastic(PVC)coating.
• Adjustablefeetforfloorstanding.• Storedwatertemperatureindicator.
Accessories on page 20
STaINLeSS STeeL heating element
Capacity Power Voltage Heat. time Δt=50°C
Insul. Thickness
Heat loss 65°C
Max. oper. temp.
Max. oper. press.
Net Weight
Hydraulic fittings Recirculation A B C D E F
l kW V~ min mm kWh/24h °C MPa kg KW-WW Z mm mm mm mm mm mm
1,5 230 294 ≥50 1,50 75 1,0 33 Rp ¾ Rp ¾ 610 654 833 213 443 608
2,0 230 294 ≥50 1,70 75 1,0 37 Rp ¾ Rp ¾ 610 654 1018 213 518 793
2,0 230 367 ≥50 2,00 75 1,0 42 Rp ¾ Rp ¾ 610 654 1290 213 618 1065
4,0 400/3 275 ≥50 2,40 75 1,0 69 Rp 1 Rp 1 650 698 1526 228 803 1283
8,0 400/3 184 ≥50 2,80 75 1,0 74 Rp 1 Rp 1 750 798 1530 263 763 1248
10,0 400/3 184 ≥50 3,30 75 1,0 84 Rp 1 Rp 1 750 798 1796 263 913 1513
1 4
Capacity
l
ISSX 120 120
ISSX 160 160
ISSX 200 200
ISSX 300/3 300
ISSX 400/3 400
ISSX 500/3 500
Interline inoxSERIES 120-160-200-300-400-500
eLeCTRIC WaTeR HeaTeRSfloor-standing storage
KW
Z
WW
�A B
C
DE
F
• AISI316Lstainlesssteelboiler,welded with “TIG” and “Plasma” technology.
• DoubleØ134mmfronthatchwayforelectrical Kit assembly and inspection.
• Ø134mmtopbottom-flangecomplete with counter-flange and probe pipe.
• Verythickexpandedpolyurethane(PU) / (EPS) insulation layer. “Easy entry” system.
• Externalcolouredplasticcoating.• Adjustablefeetforfloorstanding.• Storedwatertemperatureindicator.
Accessories on page 20
Floor-standing electric storage water heaters are designed to meet the new expectations of the market as to durability and great storage. To this end, this product line was introduced, providing maximum quality and durability owing to the use of special materials and sophisticated technological solu-tions, such as TIG and plasma welding. The insulation layer is manufactured by means of a new system that combines thetechnologyoftheinjectedpolyurethane(PU)withtheflexibilityofNEO-POR (EPS). This solution allows the installer to have a “plug and play” product and, in case of need, it is an easy solution for making the product pass through openings whose width equals 800 mm. This system allows a trouble-free di-sassembly and re-assembly of the insulation layer for an easier installation in boiler rooms. The two big front hatchways characterise the line of these pro-ducts and make them flexible and suitable for several combinations of electri-cal powers up to maximum 20 KW. The electrical components are supplied apart in handy single- and three-phase KITs with Incoloy 800 stainless steel heating elements with powers up to 10 kW. They are recommended for collec-tive use.
KITResistenza INOX
Capacty Insul. Thickness
Max. oper. temp.
Max. oper. press.
Net Weight
Hydraulic fittings
Recirculation fittings A B C D E F
mm °C MPa kg KW-WW Z mm mm mm mm mm mm
<50 75 1,0 146 Rp 1 ½ Rp 1 ½ 880 925 1865 320 982 1580
<50 75 1,0 170 Rp 1 ½ Rp 1 ½ 880 925 2245 320 1165 1960
1 5
Capacity
ISSX 800 800
ISSX 1000 1000
Interline high storage inoxSERIES 800-1000
eLeCTRIC WaTeR HeaTeRSstorage type, floor-standing
Stainless steel double coil storage indirect cylinders are made using technologies that guarantee maximum quality and durability owing to the use of special materials and sophisticated technological solutions such as “TIG” and “Plasma” welding. They can be connected to central heating systems, forced flow solar-powered systems and can be fitted with further integration systems. Recommended for industrial and collective use.• Aisi316Lstainlesssteeltankwelded
with “TIG” and “Plasma” technology.• Ø134mmfrontinspectionhatch.• Ø134mmtopinspectionflange
complete with counter flange and sensor sheath (Tr).
• Corrosion-proofmagnesiumanode.• Loweredcoiltooptimisetheheat
exchange process and limit the formation of limescale.
• Hydraulicconnectionslocated on the rear.
• Externalcolouredplastic(PVC)coating.
• Recirculationfitting.
• Storedwatertemperatureindicator.• CFCandHCFC-freeverythick
polyurethane (PU) foam insulation layer.
• Adjustablefeetforfloorstanding.• IntegrationKITSavailableforusewith
incoloy 800 stainless steel heating elements of up to 10 kW with single and three-phase connection.
• Versionfittedwith“Correx®”electronicprotection device with titanium anode and signalling LED available upon request.
Accessories on page 20
Series 120-160-200-300-400-5001 Coil
Heat exchange surface
Power (Δt 35)*
D.H.W. production (Δt 35 k)*
Heating time (Δt 35k)*
Flow resistance
Primary flow rate
Insulation thickness
Heat loss 65° C
m² kW l/h min mbar m³/h mm kWh/24h0,60 27,0 663 11 115 2,0 ≥50 1,50
0,80 36,5 896 11 117 2,0 ≥50 1,70
1,00 40,5 995 13 178 2,0 ≥50 2,00
1,40 59,0 1460 13 140 3,0 ≥50 2,40
2,00 81,0 1989 13 183 3,0 ≥50 2,80
2,40 91,0 2229 14 235 3,0 ≥50 3,30
Coil position
Surface échange
Power(Δt 35)*
D.H.W. production (Δt 35 k)*
Heating time (Δt 35k)*
Flow resistance
Primary flow rate
Insulation thickness
Heat loss 65° C
sup/inf m² kW l/h min mbar m³/h mm kWh/24hsup. 0,80 41 1006 19 130
3,0 ≥50 2,40inf. 1,30 59 1460 13 140
sup. 0,80 41 1006 25 1303,0 ≥50 2,80
inf. 1,60 65 1605 16 147sup. 0,80 41 1006 31 130
3,0 ≥50 3,30inf. 2,10 81 1989 16 183
Max. operating temperature
Max. operating pressure
Net Weight
Hydraulicfittings
Exchanger fittings
Recirculation fittings A B C D E F G H L M
°C MPa kg KW-WW PV-PR Z mm mm mm mm mm mm mm mm mm mm95 1,0 93 Rp 1 Rp 1 Rp 1 650 698 1526 228 320 688 843 969 1191 128395 1,0 100 Rp 1 Rp 1 Rp 1 750 798 1530 263 355 695 848 971 1156 124895 1,0 114 Rp 1 Rp 1 Rp 1 750 798 1796 263 355 855 1043 1208 1393 1513
Note: *Primary circuit temperature 80°C / Secondary circuit temperature 10 /45°C / Primary flow rate indicated in the table -D.H.W. = domestic hot water. top = coil at the top;-bot. = coil at the bottom
Series 300-400-5002 Coils
Max. operating temperature
Max. operating pressure
NetWeight
Hydraulicfittings
Exchangerfittings
Recirculation fittings A B C D E F G H
°C MPa kg KW-WW PV-PR Z mm mm mm mm mm mm mm mm95 1,0 38 Rp ¾ Rp ¾ Rp ¾ 610 654 833 213 323 443 533 60895 1,0 43 Rp ¾ Rp ¾ Rp ¾ 610 654 1018 213 323 518 683 79395 1,0 51 Rp ¾ Rp ¾ Rp ¾ 610 654 1290 213 323 618 783 1065 95 1,0 87 Rp 1 Rp 1 Rp 1 650 698 1526 228 338 803 918 128395 1,0 93 Rp 1 Rp 1 Rp 1 750 798 1530 263 373 763 1063 124895 1,0 110 Rp 1 Rp 1 Rp 1 750 798 1796 263 373 913 1153 1513
1 6
Capacity
l
ISSWX 120 120
ISSWX 160 160
ISSWX 200 200
ISSWX 300 300
ISSWX 400 400
ISSWX 500 500
Capacity
l
ISSWWX 300 300
ISSWWX 400 400
ISSWWX 500 500
ISSWWX 300ISSWWX 400ISSWWX 500
ISSWX 120ISSWX 160ISSWX 200ISSWX 300ISSWX 400ISSWX 500
Free Standing
HIGH STORaGestorage indirect heating
ISSWX 500ISSWX 400ISSWX 300ISSWX 200ISSWX 160ISSWX 120
ISSWX 120ISSWX 160ISSWX 200ISSWX 300ISSWX 400ISSWX 500
kW
mba
r
005001051002052003053004054005055006056007
0,50,40,30,20,1
010203040506070809001011
0,50,40,30,20,1
ISSWX 500ISSWX 400ISSWX 300ISSWX 200ISSWX 160ISSWX 120
ISSWX 120ISSWX 160ISSWX 200ISSWX 300ISSWX 400ISSWX 500
kW
mba
r
005001051002052003053004054005055006056007
0,50,40,30,20,1
010203040506070809001011
0,50,40,30,20,1
Z
VP
RP
rT
D
E
F
G
H
A
C
B
WW
KW
KW
Z
WW
PV1
PR1
PR2
PV2
DE
FGH
LM
C
A B
ISSWWX 300-500 sup.
ISSWWX 300 inf.
ISSWWX 400 inf.
ISSWWX 500 inf.
ISSWWX 300-500 sup.
ISSWWX 300 inf.
ISSWWX 400 inf.
ISSWWX 500 inf.
kW
mba
r
015102520353045405550656075708580959001501
0,50,40,30,20,1
Potenza
Portata m
005001051002052003053004054005
0,50,40,30,20,1
Perdite di carico
Portata m
ISSWWX 300-500 sup.
ISSWWX 300 inf.
ISSWWX 400 inf.
ISSWWX 500 inf.
ISSWWX 300-500 sup.
ISSWWX 300 inf.
ISSWWX 400 inf.
ISSWWX 500 inf.
kW
mba
r
015102520353045405550656075708580959001501
0,50,40,30,20,1
Potenza
Portata m
005001051002052003053004054005
0,50,40,30,20,1
Perdite di carico
Portata m
120160200300400500
120160200300400500
Power kW Flow resistance mbar
Flow rate m³ /h Flow rate m³ /h
Power kW Flow resistance mbar
Flow rate m³ /h Flow rate m³ /h
300-500 top.
300 bot.
400 bot.
500 bot.
300-500 top.
300 bot.
400 bot
500 bot.
1 Coil Inox, series: 120-160-200-300-400-500
2 Coil Inox, series: 300-400-500
1 7
INDIReCT CYLINDeRS SINGLe aND DOuBLe COIL
Double fixed coil floor-standing storage indirect cylinders are designed to meet the new expectations of the market as to durability, exchange power and great storage. To this end, this product line was introduced, providing great capacities, maxi-mum quality and durability owing to the use of special materials and sophisti-cated technological solutions, such as TIG and plasma welding.The insulation layer is manufactured by means of a new system that combines thetechnologyoftheinjectedpolyurethane(PU)withtheflexibilityofNEO-POR (EPS).This solution allows the installer to have a “plug and play” product and, in case of need, it is an easy solution for making the product pass through openings whose width equals 800 mm. This system allows a trouble-free disassembly and re-assembly of the insulation layer for an easier installation in boiler ro-oms.The two big front hatchways characterise the line of these products and make them flexible and suitable for several combinations of electrical integrations. They are recommended for collective use.
• AISI316Lstainlesssteelboiler,welded with “TIG” and “Plasma” technology.
• DoubleØ134mmfronthatchwayforelectrical Kit assembly and inspection.
• Ø134mmtopbottom-flangecomplete with counter-flange and probe pipe.
• Exchangerswithloweredturnstostreamline the heat exchange and reduce the formation of limescale.
• Verythickexpandedpolyurethane(PU) / (EPS) insulation layer. “Easy entry” system.
• Externalcolouredplasticcoating.• Adjustablefeetforfloorstanding.• Storedwatertemperatureindicator.• Theyareavailableinelectrical
integration kits with the use of Incoloy 800 stainless steel heating elements up to 10 kW with single- and three-phase connections.
Accessories on page 20
Average insul. layer thickness
Heat exchange
surface Power
(Δt 35 K)* D.H.W.
production (Δt 35 K)*
Heating time (Δt 35 K)*
Primary flow rate
Max. operating
temp.
Max. operating pressure
Net Weight
Hydraulic fittings
Exchanger fittings
Recirculation fittings
mm m² kW l/h min m³/h °C MPa kg KW-WW PV-PR Z
>100 3,05 110 2703 18 3,0 95 1,0 195 Rp 1¼ Rp 1¼ Rp 1¼
>100 3,55 130 3194 19 3,0 95 1,0 226 Rp 1¼ Rp 1¼ Rp 1¼
* Note: Primary temperature 80°C / Secondary input temperature 10/45°C / Primary capacity specified in the table - D.H.W. = Production of domestic hot water.
Average insul. layer thickness
Heat exchange
surface Power
(Δt 35 K)* D.H.W.
production (Δt 35 K)*
Heating time (Δt 35 K)*
Primary flow rate
Max. operating
temp.
Max. operating pressure
Net Weight
Hydraulic fittings
Exchanger fittings
Exchanger fittings
Recirculation fittings
mm sup/inf m² kW l/h min m³/h °C MPa kg KW-WW PV-PR Z
>100sup. 1,30 59 1460 13
3,0 95 1,0 206 Rp 1¼ Rp 1¼ Rp 1¼inf. 3,05 110 2703 18
>100sup. 1,30 59 1460 13
3,0 95 1,0 237 Rp 1¼ Rp 1¼ Rp 1¼inf. 3,55 130 3194 19
* Note: Primary temperature 80°C / Secondary input temperature 10/45°C / Primary capacity specified in the table - D.H.W. = Production of domestic hot water
Series 800-10001 Coil
Series 800-10002 Coils
1 8
Capacity
l
ISSWX 800 800
ISSWX 1000 1000
Capacity
l
ISSWWX 800
800
ISSWWX 1000
1000
Free Standinghigh storage inox
INDIReCT CYLINDeRS SINGLe aND DOuBLe COILstorage indirect heating
KW
Z
WW
PV
PR
A B
C
DE
F
G
H
KW
Z
WW
PV1
PR1
PR2
PV2
�A B
DEFG
HLM
C
A B C D E F G H
mm mm mm mm mm mm mm mm
880 925 1865 320 425 982 1187 1580
880 925 2245 320 425 1165 1303 1960
“easy entry” system
A B C D E F G H L M
mm mm mm mm mm mm mm mm mm mm
880 925 1865 320 425 985 1090 1178 1475 1580
880 925 2245 320 425 1187 1340 1578 1855 1960
1 9
ISSWX 800
ISSWX 1000
ISSWWX 800
ISSWWX 1000
INDIReCT CYLINDeRS SINGLe aND DOuBLe COIL
accessories & kit for Inox stainless steel productsCODe DeSCRIpTION
071078 1”1/4 2,0 KW 230 V- SINGLE-PHASE ELECTRICAL KIT formed by: 1”1/4 sleeve, gasket, AISI 321 stainless steel armoured heating element and thermostat to be installed on the lateral screwed connection
071079 1”1/4 3,0 KW 230 V- SINGLE-PHASE ELECTRICAL KIT formed by: 1”1/4 sleeve, gasket, AISI 321 stainless steel armoured heating element and thermostat to be installed on the lateral screwed connection
070137 3.0÷6.0 kW 400/3V˜ THREE-PHASE INOX ELECTRICAL KITRECOMMENDED FOR SERIES 160-200-300formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket.
070138 4.0÷8.0 kW 400/3 V˜ THREE-PHASE INOX ELECTRICAL KIT RECOMMENDED FOR SERIES 400-500-600-800-1000formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket.
070136 5.0÷10.0 kW 400/3 V˜ THREE-PHASE INOX ELECTRICAL KIT RECOMMENDED FOR SERIES 400-500-600-800-1000formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket.
2 0
INOX KITS aND aCCeSSORIeS
The “STReNGTHS” of the product range in detail:
2 1
This range of indirect cylinders performs indirect heating via one or two fi-xed coils or by means of an air casing with extensive heat exchange surfaces. They provide an easy and abundant supply of hot water for all uses.They can be connected to both independent and central heating systems, or to remote heating systems or they can be used in forced flow solar-powered systems, providing high heat exchange efficiency levels. The range of capa-cities covered by this product line is from 115 to 1000 litres with power ratings of between 20 kW and over 100 kW of heat output.The models available include “undermount” appliances to be fitted below the boiler, which are ideally combined with any wall-hung boiler for the pro-duction of large quantities of hot water in a limited amount of space, along with the multi-purpose “free standing” versions which comprise single and double coil indirect cylinders, designed to integrate several types of energy available, from methane gas via a gas boiler, to electrical installations using the integration kit available, and even solar energy systems with the forced flow solar-powered systems.The line of indirect cylinders is completed with the “multi-position” air casing version which has a distinguishing trait: its versatility, which makes both ver-tical and horizontal as well as floor-standing installations possible.
Thermal insulationInsulation layer made of very thick high-den-sity polyurethane (PU) foam that guarantees excellent insulation.
Tank protection against wearThanks to the “flow-coating” enamelling pro-cess at 850°C for guaranteed quality internal protection.
Magnesium anodeFeatured in all the models in the range, this anode makes for effective electrochemical tank protection.
Environmentally friendlyStyleboiler strives to optimise its industrial activity while respecting the environment. To minimise the environmental impact of its products, it has abolished the use of chloro-fluorocarbons (CFC-HCFC) in the insulation layer and makes continuous efforts to use recyclable components.
Indirect cylinders
WW
Z
PV PR
E
KW
152
A
110
082
570
159
45°
173,5
159
Potenza kW
45
101,0 2,0 2,5 3,0 4,0
15
20
25
30
35
40
BSC 115
BSC 150
Portata m³/h
kW
Perdite di carico mbar
900
01,0 2,0 2,5 3,0 4,0
150
300
450
600
750
BSC 115
BSC 150
Portata m³/h
mba
r
Potenza kW
45
101,0 2,0 2,5 3,0 4,0
15
20
25
30
35
40
BSC 115
BSC 150
Portata m³/h
kW
Perdite di carico mbar
900
01,0 2,0 2,5 3,0 4,0
150
300
450
600
750
BSC 115
BSC 150
Portata m³/h
mba
r
Power kW Flow resistance mbar
Flow rate m³ /h Flow rate m³ /h
Verticalstoragesinglecoilindirectcylindersaredesignedtobecombinedwithany wall-hung boiler for the production of large quantities of hot water despite space restrictions. They are recommended for domestic use.
• Steeltank,glass-linedusingtheflow-coating method (850 °C).
• Ø134mmtopinspectionflangecomplete with counter flange and sensor sheath (Tr).
• Corrosion-proofmagnesiumanode.• Loweredcoiltooptimisetheheat
exchange process and limit the formation of limescale.
• Recirculationandoutletfittings.• Externalcasingmadeofsheetmetal
coated with epoxy powder paint.
• Hydraulicfittingsatthetoptofacilitate connections with the wall-hung boiler.
• CFCandHCFC-freeverythickpolyurethane (PU) foam insulation layer.
• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.
• Feetforfloorstanding.• Storedwatertemperatureindicator.
Accessories on page 31/32
View from above
115
150 115
150
Capacity Heat exchange surface
Power (∆T 35 k)*
D.H.W. production (∆T 35 k)*
Heating time (ΔT 35k)*
Flow resistance
Primary flow rate
Insulation thickness
Heat loss 65 °C
l m² kW l/h min mbar m³/h mm kWh/24h0,90 27 663 11 189 2,0 ≥35 1,301,00 30 732 13 219 2,0 ≥35 1,90
Max. operating temperature
Max. operating pressure
NetWeight
Hydraulicfittings
Exchangerfittings
Recirculation fittings
Outletfitting A
°C MPa kg KW-WW PV-PR Z E mm95 1,0 53 R ¾ R ¾ R ¾ Rp ½ 86295 1,0 61 R ¾ R ¾ R ¾ Rp ½ 1064
Note: *Primary circuit temperature 80°C / Secondary circuit temperature 10 /45°C / Primary flow rate indicated in the table -D.H.W. = domestic hot water.
2 2
Capacity
ISSWG 115 115ISSWG 150 150
ISSWG 115ISSWG 150
UndermountSERIES 115-150
INDIReCT CYLINDeRS SINGLe COILvertical, storage indirect heating
PV WW
120
200
149
100
270
576
PRKWZ
561
A
PV WW
120
200
149
100
270
576
PRKWZ
561
A
10
15
20
25
30
35
40
0,35,20,25,10,1
kW
Portata m3/h
Potenza kW
0
450
300
150
0,35,20,25,10,1
Portata m3/h
mba
r
Perdite di carico mbar
ISSWT 120
ISSWT 160
ISSWT 120
ISSWT 160
10
15
20
25
30
35
40
0,35,20,25,10,1
kW
Portata m3/h
Potenza kW
0
450
300
150
0,35,20,25,10,1
Portata m3/h
mba
r
Perdite di carico mbar
ISSWT 120
ISSWT 160
ISSWT 120
ISSWT 160
Power kW Flow resistance mbar
Flow rate m³ /h Flow rate m³ /h
• Steeltank,glass-linedusing the “powder” method (850°C).
• ø 134 mm top inspec-tion flange complete with counter-flange and probe sheath (Tr).
• Corrosion-proofmagne-sium anode.
• Streamlinedcoilforthemaximum heat exchange
process and to reduce the formation of limescale.
• Outletandrecirculationfittings.
• Hydraulicfittingsinstalledin the upper part to facilitate the connection with a wall-hung boiler.
• Self-extinguishingandverythick high-density (EPS) polystyrene-shell insulation
layer.• Anti-collisionexternal
colouredPVCcoating.• Adjustablefeetforfloor
standing.• Storedwatertemperature
indicator.• Draincock.
Accessories on page 31/32
120
160
120
160
Capacity Heat exchange surface
Power (∆T 35 k)*
D.H.W. production(∆T 35 k)*
Heating time (ΔT 35k)*
Flow resistance
Primary flow rate
Insulation thickness
l m² kW l/h min mbar m³/h mm1,15 32 780 10 170 2,0 >301,20 32 780 13 172 2,0 >30
Max. operating temperature
Max. operating pressure
Netweight
Hydraulic fittings
Exchanger fittings
Recirculation fittings
Outlet fitting A
°C MPa kg KW-WW PV-PR Z E mm95 1,0 54 R ¾ R ¾ R ¾ Rp ½ 845
95 1,0 64 R ¾ R ¾ R ¾ Rp ½ 1045
* Note: Primary temperature 80°C / Secondary inlet temperature 10/45°C Primary capacity specified in the table - D.H.W. = Production of domestic hot.
Vertical single coil storage indirect cylinders aredesigned tobe combinedwith anywall-hung boiler for the production of large quantities of hot water despite space re-strictions. The rectangular shape can be suitably fitted as an undermount indirect cylin-der.ThecolouredPVCcoatingenhancesitslinesandprotectsitagainstpossiblecolli-sions during assembly operations and normal use. In addition, the product has been designed so that it can be completely disassembled at the end of its life cycle, in a way to allow its correct recycling and/or the disposal of its components. It is recommended for domestic use.
2 3
Capacity
ISSWT 120 120ISSWT 160 160
ISSWT 120ISSWT 160
UndermountSERIES 120-160
INDIRECT CYLINDERS SINGLE COILstorage type, indirect heating
Big OneSERIES 300-400-500
Indirect cylinders with increased size single fixed coil. They are designed for an easy and abundant supply of sanitary hot water by means of heat pumps. They can be connected with central heating systems and equipped with addi-tional integration systems. They are recommended for collective use.
• Steeltank,glass-linedusingtheflow-coating method (850 °C).
• Ø134mmfrontinspectionhatch.• 2Corrosion-proofmagnesiumanode.• Highefficiencyloweredcoildesigned
to optimise the thermal exchange and to reduce limestone.
• Sensorsheath(Tr)locatedontheupper part.
• Hydraulicconnectionslocated on the rear.
• Externalcolouredplastic(PVC)coating.
• Adjustablefeetforfloorstanding.
• CFCandHCFC-freethickpolyurethane(PU) foam insulation layer.
• Storedwatertemperatureindicator.• IntegrationKITSavailableforusewith
tinned copper spiral heat exchangers or copper heating elements up to 5 kW and incoloy 800 stainless steel heating elements up to 10 kW with single and three-phase connection.
Accessories on page 31/32
Hydraulic connections
Exchanger connections
Recirculation connections Vent N. of
probes A B C D E F G H L M
KW-WW PV-PR Z S Tr mm mm mm mm mm mm mm mm mm mm
Rp 1" Rp 1" Rp 1" G 3/4" 1 650 675 1560 148 338 828 1258 1408 1586 170
Rp 1" Rp 1" Rp 1" G 3/4" 1 750 775 1553 162 388 778 1228 1386 1576 190
Rp 1" Rp 1" Rp 1" G 3/4" 1 750 775 1818 162 391 931 1471 1651 1841 190
Heat exchange surface
(average) insulation layer
thickness Heat loss
65°C Maximum operating
temperature
Maximum operating pressure
Net weight
Primary flow rate
Power (Δt 35k)*
DHW production (Δt 35k)*
Pressure loss
m² mm kWh/24h °C MPa kg m³/h kW l/h mbar
3,8 ≥50 2,4 95 1,0 113 2 84 1950 425
4,5 ≥50 2,8 95 1,0 147 2 87,5 2050 461
5,5 ≥50 3,3 95 1,0 178 2 88,7 2090 563
*Primary circuit temperature 80°C / Secondary circuit temperature 10 /45°C / Primary flow rate indicated in the table / DHW= domestic hot water
newnew
2 4
ISSWH 300
ISSWH 400
ISSWH 500
Capacity
l
ISSWH 300 300
ISSWH 400 400
ISSWH 500 500
storage indirect heating INDIRECT CYLINDERS INCREASED SIzE SINGLE COIL
0
100
200
300
400
500
600
700
800
0,0 0,5 1,0 1,5 2,0 2,5 3,0
kWmbar
0
10
20
30
40
50
60
70
80
90
100
0,0 0,5 1,0 1,5 2,0 2,50
100
200
300
400
500
600
700
800
0,0 0,5 1,0 1,5 2,0 2,5 3,0
kWmbar
0
10
20
30
40
50
60
70
80
90
100
0,0 0,5 1,0 1,5 2,0 2,5
Power kW Flow resistance mbar
Flow rate m³ /h Flow rate m³ /h
300
400
500
300
400
500
2 5
INDIRECT CYLINDERS INCREASED SIzE SINGLE COIL
Single and double coil storage indirect cylinders use indirect heating. They provi-de an easy and abundant supply of hot water for all uses. They can be connected to central heating systems, forced flow solar-powered systems and can be fitted with further integration systems. Recommended for industrial and collective use.
• Steeltank,glass-linedusingthe flow-coating method (850 °C).
• Ø 134 mm front inspection hatch.
• Corrosion-proofmagnesiumanode.
• Doublecoil,optimisedformaximum heat exchange and minimum limescale build-up.
• Threesensorsheaths(Tr)
located on the rear.• Hydraulicconnections
located on the rear.• Recirculationfitting.• CFCandHCFC-freeverythick
polyurethane (PU) foam insulation layer.
• Externalcolouredplastic(PVC)coating.
• Adjustablefeetforfloorstanding.
• Storedwatertemperatureindicator.
• IntegrationKITSavailableforuse with tinned copper spiral heat exchangers or copper heating elements of up to 5 kW and incoloy 800 stainless steel heating elements of up to 10 kW with single and three-phase connection.
Accessories on page 31/32
Series 120-160-200-300-400-500-600
Heat exchange surface
Power (∆T 35 k)*
D.H.W. production(∆T 35 k)*
Heating time (ΔT 35k)*
Flow resistance Primary flow rate Insulation
thicknessHeat loss
65 °CMax. operating
temperature
m² kW l/h min mbar m³/h mm kWh/24h °C0,60 20 491 15 119 2,0 ≥50 1,50 950,85 27 663 15 182 2,0 ≥50 1,70 951,00 30 737 17 223 2,0 ≥50 2,00 951,40 44 1081 18 138 3,0 ≥50 2,40 951,70 55 1351 19 180 3,0 ≥50 2,80 952,10 63 1543 20 223 3,0 ≥50 3,30 952,90 70 1720 31 75 3,0 ≥50 3,60 95
1 Coil
Max. operating pressure
Net weight
Hydraulic fittings
Exchanger fittings
Recirculation fittings
No. of sensors A B C D E F G H L M
MPa kg KW-WW PV-PR Z Tr mm mm mm mm mm mm mm mm mm mm1,0 45 Rp ¾ Rp ¾ Rp ¾ 2 610 620 854 150 311 414 486 571 631 7201,0 57 Rp ¾ Rp ¾ Rp ¾ 2 610 620 1056 150 311 416 551 701 781 9221,0 66 Rp ¾ Rp ¾ Rp ¾ 2 610 620 1329 150 311 486 651 801 881 11951,0 97 Rp 1 Rp 1 Rp 1 2 650 675 1560 148 338 538 828 978 1058 14081,0 123 Rp 1 Rp 1 Rp 1 2 750 775 1553 162 392 560 782 932 1012 13871,0 144 Rp 1 Rp 1 Rp 1 2 750 775 1818 162 392 554 932 1082 1162 16521,0 220 Rp 1 Rp 1¼ Rp 1 2 810 832 1819 124 331 456 871 1161 1241 1659
Note: *primary circuit temperature 80°C / secondary circuit temperature 10 /45°C / primary flow rate indicated in the table -D.H.W. = domestic hot water.
Coil position
Heat exchange surface
Power (∆T 35 k)*
D.H.W. production (∆T 35 k)*
Heating time (ΔT 35k)*
Flow resistance
Primary flow rate
Insulation thickness
Heat loss65 °C
Max. operating temp.
sup/inf m² kW l/h min mbar m³/h mm kWh/24h °Csup. 0,50 22 541 23 119
2,0 ≥50 2,00 95inf. 0,70 25,5 627 21 182
sup. 0,90 31,5 774 24 1003,0 ≥50 2,40 95
inf. 1,40 44 1081 18 138sup. 0,90 31,5 774 33 100
3,0 ≥50 2,80 95inf. 1,70 55 1351 19 180
sup. 0,90 31,5 774 41 1003,0 ≥50 3,30 95
inf. 2,10 63 1543 20 223sup. 1,00 34 835 45 64
3,0 ≥ 50 3,60 95inf. 2,50 68 1671 23 73
Series 200-300-400-500-6002 Coils
Max. operating pressure
Net weight
Hydraulic fittings
Exchanger fittings
Recirculation fittings
No. of Sensors A B C D E F G H L M N O P
MPa kg KW-WW PV-PR Z Tr mm mm mm mm mm mm mm mm mm mm mm mm mm1,0 61 Rp ¾ Rp ¾ Rp ¾ 3 610 620 1329 150 261 336 581 661 747 841 1041 1108 11951,0 105 Rp 1 Rp 1 Rp 1 3 650 675 1560 148 288 378 693 773 859 956 1225 1292 14081,0 133 Rp 1 Rp 1 Rp 1 3 750 775 1553 162 322 402 722 800 879 977 1177 1259 13871,0 154 Rp 1 Rp 1 Rp 1 3 750 775 1818 162 322 437 872 972 1072 1172 1372 1457 16521,0 234 Rp 1 Rp 1 ¼ Rp 1 3 808 833 1749 123 330 435 945 1035 1110 1200 1452 1527 1658
Note: *primary circuit temperature 80°C / secondary circuit temperature 10 /45°C / primary flow rate indicated in the table -D.H.W. = domestic hot water -top = coil at the top;-bot. = coil at the bottom
2 6
Capacity
lISSW 120 120ISSW 160 160ISSW 200 200ISSW 300 300ISSW 400 400ISSW 500 500ISSW 600 600
ISSW 120ISSW 160ISSW 200ISSW 300ISSW 400ISSW 500ISSW 600
Capacity
l
ISSWW 200 200
ISSWW 300 300
ISSWW 400 400
ISSWW 500 500
ISSWW 600 600
ISSWW 200ISSWW 300ISSWW 400ISSWW 500ISSWW 600
Free Standing
vertical, storage indirect heating INDIReCT CYLINDeRS SINGLe aND DOuBLe COIL
KW
Z
WW
PV1
PR1
PR2
PV2
DE
G
LMN
P
C
A B
F
H
O
Tr
Tr
Tr
Potenza kW
85807570656055504540353025201510
1,0 2,0 3,0 5,04,0
BSS 120BSS 160BSS 200BSS 300BSS 400BSS 500BSS 600
Portata m³/h
kW
Perdite di carico mbar800750700650600550500450400350300250200150100
500
1,0 2,0 3,0 5,04,0
BSS 120BSS 160BSS 200BSS 300BSS 400BSS 500BSS 600
Portata m³/h
mbar
Potenza kW
85807570656055504540353025201510
1,0 2,0 3,0 5,04,0
BSS 120BSS 160BSS 200BSS 300BSS 400BSS 500BSS 600
Portata m³/h
kWPerdite di carico mbar
800750700650600550500450400350300250200150100
500
1,0 2,0 3,0 5,04,0
BSS 120BSS 160BSS 200BSS 300BSS 400BSS 500BSS 600
Portata m³/h
mbar
01510252035304540555065607
8057
0,40,30,20,1
kW
Potenza
Portata m
005001051002052003053004054005055006056007
0,40,30,20,1
mba
r
Perdite di carico
Portata m
ISSWW 600 inf.
ISSWW 500 inf.
ISSWW 400 inf.
ISSWW 300 inf.
ISSWW 200 inf.
ISSWW 600 sup.
ISSWW 300-500 sup.ISSWW 200 sup.
ISSWW 200 sup.
ISSWW 600 sup.
ISSWW 300-500 sup.ISSWW 200 inf.ISSWW 300 inf.ISSWW 400 inf.ISSWW 500 inf.ISSWW 600 inf.
01510252035304540555065607
8057
0,40,30,20,1
kW
Potenza
Portata m
005001051002052003053004054005055006056007
0,40,30,20,1
mba
r
Perdite di carico
Portata m
ISSWW 600 inf.
ISSWW 500 inf.
ISSWW 400 inf.
ISSWW 300 inf.
ISSWW 200 inf.
ISSWW 600 sup.
ISSWW 300-500 sup.ISSWW 200 sup.
ISSWW 200 sup.
ISSWW 600 sup.
ISSWW 300-500 sup.ISSWW 200 inf.ISSWW 300 inf.ISSWW 400 inf.ISSWW 500 inf.ISSWW 600 inf.
Power kW Flow resistance mbar
Flow rate m³ /hFlow rate m³ /h
120160200300400500600
120160200300400500600
Power kW Flow resistance mbar
Flow rate m³ /h Flow rate m³ /h
600bot.500 bot.400 bot.300 bot.200 bot.600top300-500 top200 top
200 top300-500 top200 bot.300 bot.400 bot.500 bot.600bot.600top
1 Coil, series 120-160-200-300-400-500-600
2 Coil, series 200-300-400-500-600
2 7
INDIReCT CYLINDeRS SINGLe aND DOuBLe COIL
Single and double fixed coil floor-standing storage indirect cylinders are desi-gned to meet the new expectations of the market as to durability, exchange power and great storage.To this end, this new high-capacity product line was introduced, providing maximum quality and durability owing to the use of special materials and so-phisticated technological solutions.The guarantee of durability in time is further extended by means of a modern “glass-lining” treatment over the tank.The insulation layer is manufactured by means of a new system that combines thetechnologyoftheinjectedpolyurethane(PU)withtheflexibilityofNEO-POR (EPS). This solution allows the installer to have a “plug and play” product and, in case of need, it is an easy solution for making the product pass through openings whose width equals 800 mm. This system allows a trouble-free disassembly and re-assembly of the insula-tion layer for an easier installation in boiler rooms. The two big front hatchways characterise the line of these products and make them flexible and suitable for several combinations of electrical powers up to maximum 20 kW. The electrical components are supplied apart in handy sin-gle- and three-phase KITs with Incoloy 800 stainless steel heating elements with powers up to 10 kW or made of copper up to 5 kW. Furthermore, you can equip the tank with spiroid exchangers, if any, which can be installed in the hatchways. They are recommended for collective use.
• Glass-linedsteelboiler.• DoubleØ134mmfronthatchwayfor
electrical Kit assembly and inspection.• Ø134mmtopbottom-flangecomplete
with counter-flange.• Streamlineddoublecoilforthemaximum
heat exchange process and to reduce the formation of limescale.
• Verythickexpandedpolyurethane(PU)/(EPS) insulation layer. “Easy entry” system.
• Externalcolouredplasticcoating.• Adjustablefeetforfloorstanding.• Storedwatertemperatureindicator.• Theyareavailableinelectricalintegration
kits with the use of Incoloy 800 stainless
steel heating elements up to 10 kW with single- and three-phase connections.
Accessories on page 31/32
Average insul. layer thickness
Heat exchange
surface Power
(∆T 35 k)*D.H.W.
production(∆T 35 k)*
Heating time
(ΔT 35k)*
Primary flow rate
Max. operating
temp.
Max. operating pressure
Net weight
Hydraulic fittings
Exchanger fittings
Recirculation fittings
mm m² kW l/h min m³/h °C MPa kg KW-WW PV-PR Z
>100 3,00 88 2162 24 3,0 95 1,0 272 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼
>100 3,50 100 2457 26 3,0 95 1,0 299 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼
* Note: Primary temperature 80°C / Secondary temperature:10/45°C - D.H.W. = production of domestic hot water.
Series 800-1000
1 Coil
Average insul. layer thickness
Coil fittings
Heat exchange
surface Power
(∆T 35 k)*D.H.W.
production(∆T 35 k)*
Heating time
(ΔT 35k)*
Primary flow rate
Max. operating
temp.
Max. operating pressure
Net weight
Hydraulic fittings
Exchanger fittings
Recirculation fittings
mm top/bot. m² kW l/h min m³/h °C MPa kg KW-WW PV-PR Z
>100top 1,20 40 983 52
3,0 95 1,0 292 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼172227 3,00 88 2162 24
>100top 1,50 48 1179 54
3,0 95 1,0 323 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼bot. 3,50 100 2457 26
* Note: Primary temperature 80°C / Secondary temperature 10/45°C / D.H.W. = production of domestic hot water
2 CoilSeries 800-1000
2 8
Capacity
l
ISSW 800 800
ISSW 1000 1000
Capacity
l
ISSWW 800 800
ISSWW 1000 1000
Free Standinghigh storage
storage indirect heating INDIReCT CYLINDeR SINGLe aND DOuBLe COIL
KW
Z
WW
PV
PR
C
A B
DEFG
H
�
KW
Z
WW
PV1
PR1
PR2
PV2
C
A B
DE
FGHLM
�
“easy entry” system
A B C D E F G H
mm mm mm mm mm mm mm mm
880 925 1865 191 371 1071 971 1676
880 925 2245 191 371 1231 1121 2056
A B C D E F G H L M
mm mm mm mm mm mm mm mm mm mm
880 925 1865 191 371 1071 971 1251 1461 1676
880 925 2245 191 371 1231 1121 1431 1831 2056
2 9
ISSW 800
ISSW 1000
ISSWW 800
ISSWW 1000
INDIReCT CYLINDeR SINGLe aND DOuBLe COIL
Potenza kW
50
45
40
35
30
25
20
15
50,5 1 1,5 2,52
0,5 1 1,5 2,52
BMI 80
BMI 100
BMI 115 - 150
BMI 200
BMI 300
Portata m³/h
kW
Produzione A.C.S l/h
700800900
100011001200
600500400300200100
Portata m³/h
l/h
BMI 80
BMI 100
BMI 115 - 150
BMI 200
BMI 300
Potenza kW
50
45
40
35
30
25
20
15
50,5 1 1,5 2,52
0,5 1 1,5 2,52
BMI 80
BMI 100
BMI 115 - 150
BMI 200
BMI 300
Portata m³/h
kW
Produzione A.C.S l/h
700800900
100011001200
600500400300200100
Portata m³/h
l/h
BMI 80
BMI 100
BMI 115 - 150
BMI 200
BMI 300
Power kW D.H.W. production l/h
80100115-150200300
80100115-150200300
MultipositionSERIES 80-100-115-150-200-300
Multi-position storage air casing indirect cylinders are a convenient and cheap so-lution to your domestic hot water requirements. Their strength lies in the exhausti-ve nature of the range, from 80 to 300 litres, and in the versatility of installation; moreover, thanks to the limited flow resistance, they are ideal for use in natural flow systems. Recommended for domestic and collective use.• Steeltank,glass-linedusingthe
flow-coating method (850 °C).• �88mminspectionflangecomplete
with counter flange and sensor sheath.• Corrosion-proofmagnesiumanode.• Heatexchangerwithaircasing,
optimised for natural flow systems owing to the reduced flow resistance.
• CFCandHCFC-freepolyurethane(PU)foam insulation layer.
• Recirculationfitting.
• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.
• Primarycircuitfittingsonbothsidesformaximum installation flexibility.
• Multi-positioninstallationoptions:vertical or horizontal, wall-mounted or floor-standing (floor-standing installa-tion only for mod. 300).
• ElectricintegrationKITSavailable(exceptfor the 300 litre model).
Accessories on page 31/32
Versions80-100-115-150-200
Version300
Max. operating pressure
Max. operating pressure
of air casingNet
WeightHydraulic
fittingsExchanger
fittingsRecirculation
fittings A B C D E F G H L
MPa MPa kg KW-WW PV-PR Z mm mm mm mm mm mm mm mm mm0,8 0,4 42 R ¾ Rp 1 ¼ R ¾ 470 844 223 463 295 65 65 257 3200,8 0,4 51 R ¾ Rp 1 ¼ R ¾ 470 1057 223 856 295 65 65 257 5000,8 0,4 59,5 R ¾ Rp 1 ¼ R ¾ 470 1228 223 1027 295 65 65 257 6700,8 0,4 67 R ¾ Rp 1 ¼ R ¾ 570 1025 214 819 450 115 115 262 5000,8 0,4 83,5 R ¾ Rp 1 ¼ R ¾ 570 1295 214 1086 450 115 115 262 8000,8 0,4 130 R 1 Rp 1 ¼ R 1 see diagram
Note: *primary circuit temperature 80°C / secondary circuit temp 10 /45°C / primary flow rate indicated in the table -D.H.W. = domestic hot water. Floor-standing installation only for model GMI 300.
Capacity Heat exchange surface
Power (∆T 35 k)*
D.H.W. production (∆T 35 k)*
Heating time (ΔT 35k)*
Primary flow rate
Max. operating temperature
m² kW l/h min m³/h °C0,65 14 350 15 2,0 950,90 22 540 12 2,0 951,10 26 645 11 2,0 951,10 26 645 15 2,0 951,50 33 815 16 2,0 952,00 45 1115 17 2,0 95
Flow rate m³ /h Flow rate m³ /h
3 0
GmI 80GmI 100GmI 115GmI 150GmI 200GmI 300
Capacity
lGmI 80 80GmI 100 100GmI 115 115GmI 150 150GmI 200 200GmI 300 300
storage indirect heating INDIReCT CYLINDeRS SINGLe COIL
accessories & kit for indirect cylinder
CODe DeSCRIpTION
070281 PRIORITY KIT formed by: thermostat in exchange, two-contact relay, bipolar switch, wired cap.
071037 1”1/4 2,0 KW 230 V- SINGLE-PHASE ELECTRICAL KIT formed by: 1”1/4 sleeve, gasket, armoured heating element and thermostat to be installed on the lateral screwed connection
071038 1”1/4 3,0 KW 230 V- SINGLE-PHASE ELECTRICAL KIT composto da: manicotto 1 ¼, guarnizione, resistenza blindata in rame e termostato per installazione su predisposizione attacco filettato laterale
071078 1”1/4 2,0 KW 230 V- SINGLE-PHASE ELECTRICAL KIT formed by: 1”1/4 sleeve, gasket, AISI 321 stainless steel armoured heating element and thermostat to be installed on the lateral screwed connection
071079 1”1/4 3,0 KW 230 V- SINGLE-PHASE ELECTRICAL KIT formed by: 1”1/4 sleeve, gasket, AISI 321 stainless steel armoured heating element and thermostat to be installed on the lateral screwed connection
070265 2.0 kW 230 V~ 1” SINGLE-PHASE ELECTRICAL KITformed by: counter-flange with 1” sleeve, gasket, copper armoured heating element and thermostat.
070266 3.0 kW 230 V~ 1” SINGLE-PHASE ELECTRICAL KIT formed by: counter-flange with 1” sleeve, gasket, copper armoured heating element and thermostat.
070267 3.0 kW 400/3 V~ 2” THREE-PHASE ELECTRICAL KIT cormed by: counter-flange with 2” sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectors.N.B. not suitable for 800 L and 1000 L model
070268 4.0 kW 400/3 V~ 2” THREE-PHASE ELECTRICAL KITformed by: counter-flange with 2” sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectors.N.B. not suitable for 800 L and 1000 L model
070269 5.0 kW 400/3 V~ 2” THREE-PHASE ELECTRICAL KIT formed by: counter-flange with 2” sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectors.N.B. not suitable for 800 L and 1000 L model
3 1
UNDERMOUNT
FREE STANDING
FREE STANDING
FREE STANDING
FREE STANDING
INDIReCT CYLINDeR
accessories & kit for indirect cylinder
CODe DeSCRIpTION
030528 SPIROID EXCHANGER KIT 1.0 sqm formed by: counter-flange, finned coil made of tinned copper 1 sqm; gasket, union set, round grill, fastening screws and nuts. FOR ALL SERIES
030525 SPIROID EXCHANGER KIT 1.8 sqm ONLY FOR SERIES 400-500-600-800-1000 formed by: counter-flange, finned coil made of tinned copper 1.8 sqm; gasket, union set, round grill, fastening screws and nuts..
070137 3.0÷6.0 kW 400/3V~ THREE-PHASE INOX ELECTRICAL KIT formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. RECOMMENDED FOR SERIES 160-200-300
070138 4.0÷8.0 kW 400/3 V~ THREE-PHASE INOX ELECTRICAL KIT formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. RECOMMENDED FOR SERIES 400-500-600-800-1000
070136 5.0÷8.0 kW 400/3 V~ THREE-PHASE INOX ELECTRICAL KITformed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. RECOMMENDED FOR SERIES 400-500-600-800-1000
070133 1.2 kW 230 V~ ELECTRICAL KIT - FOR SERIES 80-100 formed by: copper armoured heating element, thermostat and wired cap. Only for wall-mount vertical or horizontal installations.
070134 1.5 kW 230 V~ ELECTRICAL KIT - FOR SERIES 115 formed by: copper armoured heating element, thermostat and wired cap.Only for wall-mount vertical or horizontal installations
070127 2.0 kW 230 V~ ELECTRICAL KIT - FOR SERIES 150-200
090629 Feet for floor standing. FOR SERIES 80-100-115-150-200
3 2
FREE STANDING
FREE STANDING
MULTIPOSITION
INDIReCT CYLINDeR
Thermal insulation layerIt is manufactured with very thick and high-density polyurethane foam to assure excel-lent thermal insulation.• Rigidpolyurethane(PU)for200÷600lmodels.• Flexiblepolyurethane(PU)for800÷1.000lt. models.
Recycling800 and 1,000l puffers have been designed so that they can be completely disassembled at the end of their life cycle, in a way to allow their correct recycling and/or the disposal of their components.
Respect of the environmentWe undertakes streamlining the industrial activities and the respect of the environment. In order to reduce the impact over the envi-ronment to the minimum, we removed the hydrofluorocarbons (CFC-HCFC) from the insulation layer, and always pays great atten-tion to the recyclability of the components.
The “STReNGTHS” of the product range in detail:
The range of inertial puffers is formed by heating water storages with the opportunity to combine a fixed coil exchanger, too. They allow storing heating water generated by discontinuous heating sy-stems; therefore, they allow a considerable recovery and/or exploitation of thermal energy that would be unused or even wasted. From this point of view, they well integrate into energy saving systems, and become the “thermal source” of the energy system within heating and dome-stic hot water generation systems.Owing to their peculiarity, they are usually connected to systems that ge-nerate heat in a discontinuous way, such as for example wood-fired boilers, solid-fuel stacks or stoves, or rather installed in low water systems to limit the interventions of the burners.As for the version with fixed exchanger, besides what is said above, it is used for maximum exploitation of “thermal solar systems” or with “heat pump”. The capacity field covered by this range is included between 200 and 1,000 litres.Product lines cover the standard, with front hatchway, solar with fixed exchanger and front hatchway up to solar with the production of domestic hot water. All products are equipped with fittings for electric integrations by means of specific kits from 3.0 kW to 12.0 kW, while the products having the hatchway can install further electric kits from 2.0 to 10.0 kW, or kits with tinned copper spiroid exchangers.
3 3
Inertial puffers
Inertial puffers are characterised by the ability to store heating water that co-mes from several sources, mainly discontinuous ones.In addition, they are arranged for the installation of an electric integration, which is supplied by means of specific kits up to 12 kW.
• Rawcarbonsteelinternaltank.
• Hydraulicfittingstobefound on the rear.
• Probesheaths(Tr)tobefound on the rear.
• CFCandHCFC-freeverythick rigid expanded polyurethane (PU)
insulation layer. “Easy entry” system plus (EPS) for series 800/1000.
• Externalcolouredplastic(PVC)coating.
• Adjustablefeetforfloorstanding.
• Arrangementofelectricheating element with
front 1” sleeve.• AvailableelectricalKIT
with Incoloy 825 stainless steel heating elements on a 1” fitting with powers from 3 to 12 kW and three-phase connection.
Series 200-300-400-500-600-700-800-1000Insulation layer
thicknessMax. working temperature
Max. working pressure
Net weight
Heating element fitting
Hydraulicfittings
Fitting on upper bottom
Number of probes/diameter Nr/mm
mm °C MPa kg R M, RI, RC, SC, Ric Nr/mm>50 PU 95 0,3 51 Rp 1 ½ Rp ¾ Rp 2 3/Ø16>50 PU 95 0,3 75 Rp 1 ½ Rp 1 Rp 2 3/Ø16>50 PU 95 0,3 97 Rp 1 ½ Rp 1 Rp 2 3/Ø16>50 PU 95 0,3 113 Rp 1 ½ Rp 1 Rp 2 3/Ø16>50 PU 95 0,3 174 Rp 1 ½ Rp 1 Rp 2 3/Ø16
>50 95 0,3 140 Rp 1 ½ Rp 1 ¼ Rp 2 3/Rp1/2>50 95 0,3 164 Rp 1 ½ Rp 1 ¼ Rp 2 3/Rp1/2
Series 200-300-400-500-600-700-800-1000
Capacity Insulation layer thickness
Max. working temperature
Max. working pressure
Net weight
Heating element fitting
Hydraulicfittings
Fitting on upper bottom
Number of probes/diameter Nr/mm
l mm °C MPa kg R M, RI, RC, SC, Ric Nr/mm>50 PU 95 0,3 53 Rp 1 ½ Rp ¾ Rp 2 3/Ø16>50 PU 95 0,3 77 Rp 1 ½ Rp 1 Rp 2 3/Ø16>50 PU 95 0,3 99 Rp 1 ½ Rp 1 Rp 2 3/Ø16>50 PU 95 0,3 115 Rp 1 ½ Rp 1 Rp 2 3/Ø16>50 PU 95 0,3 176 Rp 1 ½ Rp 1 Rp 2 3/Ø16
>50 95 0,3 143 Rp 1 ½ Rp 1 ¼ Rp 2 3/Rp1/2>50 95 0,3 167 Rp 1 ½ Rp 1 ¼ Rp 2 3/Rp1/2
Series 800-1000Exchange
surfacePower
(Δt 35)*D.H.W. production
(Δt 35 k)*Heating time
(Δt 35k)Primary capacity
Insulation layer thickness
Maximum working temperature
m² kW l/h min m³/h mm °C3,00 88 2162 24 3,0 >50 953,50 100 2457 26 3,0 >50 95
Maximum workingpressure
Net weight
Exchanger fittings
Heating element fitting
Hydraulic fittings
Fitting on upper bottom
Number of probes/diameter
MPa kg PV-PR R M, RI, RC, SC, Ric Nr/mm0,3 205 Rp 1 ¼ Rp 1 ½ Rp 1 ¼ Rp 2 3/Rp1/20,3 241 Rp 1 ¼ Rp 1 ½ Rp 1 ¼ Rp 2 3/Rp1/2
3 TO 9 KW 1 1/2 INCOLOY 825 STAINLESS STEEL THREE-PHASE HEATING ELEMENT ELECTRICAL KIT
071000 3kW400/3V-1”1/2electricalkit
071001 6kW400/3V-1”1/2electricalkit
071002 9kW400/3V-1”1/2electricalkit
3 4
Capacity
lISpHO 200 200ISpHO 300 300ISpHO 400 400ISpHO 500 500ISpHO 600 600ISpHO 800 800ISpHO 1000 1000
Capacity
ISpH 200 200ISpH 300 300ISpH 400 400ISpH 500 500ISpH 600 600ISpH 800 800ISpH 1000 1000
Capacity
ISpHW 750 750ISpHW 950 950
ISpHW 750ISpHW 950
PH
PH no HatCHway
PH witH HatCHway
PH witH HatCHway and one Coil
puFFeR Intertial Puffer
CS /2 IR
CR
I .ciR1 IR
2 IM
CM
1 IM
rT
rT
rT
DE
FG
HL
M
R
AØ
N
RI 2 / SC
RC
Ric. I
RI 1
MI 2
MC
MI 1
A
C
N
R
0
DE
FG
HL
M
N
C
RI 2 / SC
RC
Tr
Tr
Tr
Ric.1
Rl1
Ml 2
Ml 1
MC
R
B
ML
HG F
ED
OA
RI 2 / SC
RC
Ric. IRI 1
MI 2
MC
MI 1
A
C
N
R
0
DE
FG
HL
M
B�
RI 2 / SC
RC
Ric. IRI 1MI 2
MC
MI 1
SCA 1
SCAU
C
A
DE
FG
HL
M
NO
P
R
A C D E F G H L M N
mm mm mm mm mm mm mm mm mm mm610 1329 150 261 621 761 841 1041 1195 735650 1560 156 336 751 841 984 1236 1416 785755 1553 161 321 721 878 976 1176 1385 839755 1818 161 364 914 1056 1131 1381 1651 906810 1749 123 330 930 1075 1150 1400 1658 891880 1865 191 371 971 1071 1251 1461 1676 1123880 2245 191 371 1121 1231 1431 1831 2056 1268
with hatchway 200÷600
with hatchway and one coil
NO hatchway
with hatchway 800÷1000
A B C D E F G H L M N
mm mm mm mm mm mm mm mm mm mm mm610 627 1329 150 261 621 761 841 1041 1195 735650 674 1560 156 336 751 841 984 1236 1416 785755 775 1553 161 321 721 878 976 1176 1385 839755 775 1818 161 364 914 1056 1131 1381 1651 906810 827 1749 123 330 930 1075 1150 1400 1658 891880 910 1865 191 371 971 1071 1251 1461 1676 1123880 910 2245 191 371 1121 1231 1431 1831 2056 1268
A B C D E F G H L M N O
mm mm mm mm mm mm mm mm mm mm mm mm880 910 1865 191 371 971 1071 1251 1461 1676 371 971880 910 2245 191 371 1121 1231 1431 1831 2056 371 1121
3 5
ISpHO 200ISpHO 300ISpHO 400ISpHO 500ISpHO 600ISpHO 800ISpHO 1000
ISpH 200ISpH 300ISpH 400ISpH 500ISpH 600ISpH 800ISpH 1000
ISpH W 750ISpH W 950
puFFeR
The “Tank in Tank” range of solar puffers with the production of domestic hot water is an integrated system formed by a thermal storage for heating (puffer) and a glass-lined tank, which is dipped inside the puffer, for the production of domestic hot water.The insulation layer is manufactured by means of a new system that combines thetechnologyoftheinjectedpolyurethane(PU)withtheflexibilityofNEO-POR (EPS) (only for series 750-900). This solution allows the installer to have a “plug and play” product and, in case of need, it is an easy solution for making the product pass through openings whose width equals 800 mm. This system allows a trouble-free disassembly and re-assembly of the insula-tion layer for an easier installation in boiler rooms. Owing to their peculiarity, they are usually connected to systems that genera-te heat in a discontinuous way, such as for example wood-fired boilers, solid-fuel stacks or stoves, or rather installed in low water systems to limit the inter-ventions of the burners.The fixed exchanger to be found in the system is used for maximum exploita-tion of “thermal solar systems” or with “heat pump”.
• Rawcarbonsteelinternaltank(puffer).• Carbonsteelfixedexchangerwelded
to the puffer.• Perforateddiaphragmfastenedtothe
puffer for improved internal lamina-tion.
• Domestichotwatersteeltank,glass-lined using the flow-coating method (850°C).
• Corrosion-proofmagnesiumanode(domestic hot water tank).
• Hydraulicfittingstobefound on the rear.
• Probesheaths(Tr)tobefound on the rear.
• CFCandHCFC-freeverythickexpanded polyurethane insulation layer.
• “Easyentry”systemforseries750 and 900.
• Externalcolouredplastic(PVC)coating.
• Adjustablefeetforfloorstanding.
D.H.W. capacity
Exchange surface
Power (Δt 35)*
Insulation layer thickness
Maximum working temperature
Heating working maximum pressure
l m² kW mm °C MPa
130 2,10 81 ≥ 50 95 0,3
180 2,50 91 ≥ 50 95 0,3
230 3,00 105 ≥ 50 95 0,3
DHW working maximum pressure
Net weight
Exchanger fittings
Vent fitting
DHW fittings
Heating fitting
Number of probes/diameter
MPa kg PV-PR SF WW, Z, KW HZ VL, HZ RL Nr/mm
0,8 190 Rp 1 ¼ Rp ¾ Rp ¾ Rp 1 4/ Rp ½
0,8 220 Rp 1 ¼ Rp ¾ Rp ¾ Rp 1 ¼ 4/ Rp ½
0,8 260 Rp 1 ¼ Rp ¾ Rp ¾ Rp 1 ¼ 4/ Rp ½
3 6
Heating capacity
l
TTS 600/130 470
TTS 750/180 570
TTS 900/230 670
TTS 600/130
TTS 750/180
TTS 900/230
TTSSERIES 600-750-900
SOLaR puFFeRTank in Tank
WW KW
C/SPR
PV
Tr
Tr
Tr
Tr
DEFGH
ILP
�A
NO
M
SF
Z
C
B
att� att�
att� att�
att� att�
att� att�
att�
A C D E F G H L M N O
mm mm mm mm mm mm mm mm mm mm mm
810 780 1831 130 270 395 870 1603 200 180 245
880 800 1932 196 351 445 951 1623 200 180 245
880 800 2305 196 376 481 1026 1996 200 180 245
3 7
TTS 600/130
TTS 750/180
TTS 900/230
SOLaR puFFeR
The range of gas water heaters is the result of detailed research and in-depth experiments related to the efficiency, safety, aesthetic appearance and ener-gy savings in strict compliance with the applicable norms in force. The range of capacities covered by this product line is from 50 to 2000 litres with power ratings of between 4 kW and over 34 kW of heat output. The ran-ge meets both the domestic requirements of a typical home as well as those of industrial and collective settings. The product lines include “natural draught” appliances, which are ideal for the rapid and cheap production both small and large quantities of water, as well as the sophisticated “fan flue” appliances which also solve installation difficulties when traditional systems cannot be fitted.
Thermal insulationInsulation layer made of very thick (range for collective use) high-density polyurethane (PU) foam that guarantees excellent insula-tion.
Tank protection against wearThanks to the “flow-coating” enamelling pro-cess at 850°C for guaranteed quality internal protection or via classic hot galvanising process(forseries600-2000only).
Magnesium anodeFeatured in all the models in the range, this anode makes for effective electrochemical tank protection.
Multi-gas burnerAll the gas powered appliance models are fit-ted with multi-gas burners for operation with methane gas or LPG.
Maximum safetyTriple safety gas valve with operating ther-mostat, flame detection thermocouple (ioni-sation for electronic versions) and maximum temperature thermostat and flue gas sensor (for natural draught versions) to avoid possi-ble malfunctions.
Environmentally friendlyWe strive to optimise its industrial activity while respecting the environment. To mini-mise the environmental impact of its pro-ducts, it has abolished the use of chlorofluo-rocarbons (CFC-HCFC) in the insulation layer and makes continuous efforts to use recycla-ble components.
The “STReNGTHS” of the product range in detail:
3 9
Gas water heaters
G
A
450
475
F
112
100
348
B
22WW KW
Natural draughtSERIES 50-80-100-120
Wall-hungstorageopen-ventedand“Naturaldraught”gaswaterheatersarethe simplest and cheapest solution for the rapid production of domestic hot water.
• Steeltank,glass-linedusingthe“flow-coating” method (850°C).
• Corrosion-proofmagnesiumanode.• CFCandHCFC-freepolyurethane(PU)
foam insulation layer.• Externalcasingmadeofsheetmetal
coated with epoxy powder paint.• Piezoelectricignition.• Burnerwith3distributingpipes.• Triplesafetygasvalve:operating
thermostat, flame detection thermo-couple and maximum temperature control.
• Fluegassensor(DCF).• Storedwatertemperatureindicator.• Designedtooperateonmethanegas
or LPG (nozzles included).• Operationwithoutelectricalconnec-
tions.
Capacity Heat Output
Useful Power
Heat. time Δt=50°C
Cont. flow rate
Δt=30°C
Max. qty. of flue gases
Flue gas temp.
Methane consumption
LPG consumption
Max. operating
temp.
Max. operating
press.Net
WeightHydraulic
fittingsGas
fittingØFlue gas discharge A B
l kW kW min l/min g/s °C m³/h g/h °C MPa kg KW-WW G F (mm) mm mm
4,5 3,8 43 1,8 1,96 308 0,50 300 75 0,8 20 R ½ G 3/8 81 654 261
6,2 5,3 55 2,5 2,75 292 0,65 395 75 0,8 28 R ½ G 3/8 81 939 546
6,2 5,3 65 2,5 3,22 284 0,65 395 75 0,8 32 R ½ G 3/8 81 1024 631
6,5 5,6 77 2,7 3,31 275 0,70 425 75 0,8 36 R ½ G 3/8 81 1174 781
Note: open-vented, natural draught B11BS / category II 2H3+
View from above
Ø
4 0
Capacity
eGN 50 45
eGN 80 80
eGN 100 94
eGN 120 118
GaS WaTeR HeaTeRwall-hung, storage open-vented
G
072
286
C
AB
204
160
160
470
212
D
F
WW KW
Fan flueSERIES 80-120
Wall-hung storage room-sealed and “Fan flue” gas water heaters are a sophisti-cated yet brilliant way to solve the most challenging installation difficulties where traditional appliances cannot be used, for the rapid production of do-mestic hot water.
• Steeltank,glass-linedusingthe“flow-coating” method (850°C).
• Corrosion-proofmagnesiumanode.• CFCandHCFC-freepolyurethane(PU)
foam insulation layer.• Externalcasingmadeofsheetmetal
coated with epoxy powder paint.• Electronicignitionwithflame
detection and ionisation flame control.
• Fluegasextractionfanwithsafetypressure switch.
• Triplesafetygasvalve:operatingthermostat, ionisation flame detection and maximum temperature control.
• Storedwatertemperatureindicator.• Designedtooperateonmethanegas
or LPG (nozzles included).• Coaxialorsplitfluegasdischarge
available.
Accessories on page 46
View from above
Capacity Heat Output
Useful Power
Heat. time Δt=50°C
Cont. flow rate Δt=30°C
Max. qty. of flue gases
Flue gas
temp.Methane
consumptionLPG
consumptionMax.
operating temp.
Max. operating
press.Net
weightHydraulic
fittingsGas
fittingØ Flue
gas discharge
A B C D
l kW kW min l/min g/s °C m³/h g/h °C MPa kg KW-WW G F (mm) mm mm mm mm
4,0 3,4 84 1,6 2,20 91 0,42 246 75 0,8 40 R ½ R 3/8 28 1069 940 360 632
4,0 3,4 127 1,6 2,20 91 0,42 246 75 0,8 48 R ½ R 3/8 28 1300 1171 591 867
Note: room-sealed, fan flue C12 C32 C42 C82 / category II 2H3+ / Max absorbed power: 44W -230V~
4 1
Capacity
TF 80 78
TF 120 118
GaS WaTeR HeaTeRwall-hung, storage room-sealed
118
25970
Z
E
G
669
1417
1479
Z
EG
374
C
AB
F470
230 230
65
WW KW WW KW
570F
Ø
Natural draughtSERIES 115-150-200
Floor-standingstorageopen-ventedand“Naturaldraught”gaswaterheatersare the best solution for the production of large quantities of domestic hot water. They are also ideal for collective use (on campsites, in sports facilities and hotels, for example) and in industrial settings.
• Steeltank,glass-linedusingthe“flow-coating” method (850°C).
• Corrosion-proofmagnesiumanode.• CFCandHCFC-freepolyurethane(PU)
foam insulation layer.• Externalcasingmadeofsheetmetal
coated with epoxy powder paint.• Piezoelectricignition.• Storedwatertemperatureindicator.
• Triplesafetygasvalve:operatingthermostat, flame detection thermo-couple and maximum temperature control.
• Fluegassensor(DCF).• Designedtooperateonmethanegas
or LPG (nozzles included).• Operationwithoutelectricalconnec-
tions.
115/150 200
Capacity Heat output
Useful power
Heat. time
∆t=50°C
Cont. flow rate ∆t=30°C
Max. qty. of flue gases
Flue gas
temp.
Methane consum-
ption
LPG consum-
ption
Max. operating
temp.
Max. operating
press.Net
weightHydraulic
fittingsRecirculation
and discharge
Gas fitting
ØFlue gas
dischargeA B C
l kW kW min l/min g/s °C m³/h g/h °C MPa kg KW-WW Z-E G F (mm) mm mm mm
6,9 5,7 72 2,7 3,36 284 0,75 445 75 0,8 41 R ¾ Rp ¾ R ½ 81 1212 1274 674
7,2 6,0 92 2,8 3,80 242 0,76 445 75 0,8 50 R ¾ Rp ¾ R ½ 81 1511 1573 824
8,0 6,6 111 3,2 3,76 234 0,84 495 75 0,8 71 R ¾ Rp ¾ R ½ 81 Vedi schema
Note: open-vented, natural draught B11BS / category II 2H3+
View from above
View from above
4 2
Capacity
l
eG/p 115 112
eG/p 150 150
eG/p 200 200
GaS WaTeR HeaTeRwall-hung, storage open-vented
G
E
Z
499
A
133
F
499B
C
720
E
499
499B
C
A
Z
WW
KW
WW
KW
F 720
G
Natural draughtSERIES 300-500
Floor-standingstorageopen-ventedand“Naturaldraught”gaswaterheatersare designed to store large quantities of hot water with a view to ensuring greater value for money. The version featuring electronic ignition combines economic use with maximum flame control precision. These water heaters are ideal for collective use (on campsites, in sports facilities and hotels, for exam-ple) and in industrial settings.
• Steeltank,glass-linedusingtheflow-coating method (850°C).
• ø 134 mm front inspection hatch.• Corrosion-proofmagnesiumanode.• CFCandHCFC-freeverythick
polyurethane (PU) foam insulation layer.
• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.
• Fluegassensor(DCF).
• Piezoelectricignition(electronicforthe EG/PRE version).
• Triplesafetygasvalve:operatingthermostat, flame detection thermo-couple (ionisation for the EG/PRE version) and maximum temperature control.
• Storedwatertemperatureindicator.• Designedtooperateonmethanegas
or LPG (nozzles included).
300/500 300/500electronic version
Capacity Heat output
Useful Power
Heat. time
∆t=50°C
Cont. flow rate
∆t=30°C
Max. qty.
of flue gases
Flue gas
temp.
Methane consum-
ption
LPG consum-
ption
Max. operating
temp.
Max. operating
press.Net
weightHydraulic
fittingsRecirculation
and discharge
Gas fitting
ØFlue gas
dischargeA B C
l kW kW min l/min g/s °C m³/h g/h °C MPa kg KW-WW Z-E G F (mm) mm mm mm
19,5 17,2 62 8,2 9,59 230 2,10 1250 75 0,8 133 Rp 1 Rp ¾ R ¾ 122 1611 821 1084
19,5 17,2 62 8,2 9,59 230 2,10 1250 75 0,8 133 Rp 1 Rp ¾ R ¾ 122 1611 821 1084
24,0 21,0 82 10,0 11,58 214 2,52 1500 75 0,8 178 Rp 1 Rp ¾ R ¾ 122 2144 1285 1643
24,0 21,0 82 10,0 11,58 214 2,52 1500 75 0,8 178 Rp 1 Rp ¾ R ¾ 122 2144 1285 1643
Note: for the EG/PRE electronic version, the appliance needs to be connected to the 230 V~ electricity mains / open-vented, natural draught B11BS / category II 2H3+
4 3
Capacity
eG/pR 300 290
eG/pRe 300* 290
eG/pR 500 470
eG/pRe 500* 470
GaS WaTeR HeaTeRwall-hung, storage open-vented
Z
A F
GE
D
B
C
WW
KW
Natural draughtSERIES 600-800-1000-1500-2000
Floor-standingstorageopen-ventedand“Naturaldraught”highcapacitygaswater heaters provide large quantities of hot water and can be installed in series/parallel where large consumption levels are required. The version featu-ring electronic ignition combines economic use with maximum flame control precision. These water heaters are ideal for collective use (on campsites, in sports facilities and hotels, for example) and in industrial settings.
• Hotgalvanisedsteeltank.• Corrosion-proofmagnesiumanode.• Verythickmineralwoolinsulation
layer for reduced heat loss.• Storedwatertemperatureindicator.• Externalcasingmadeofpre-painted
sheet metal.• Piezoelectricignition.• Triplesafetygasvalve:operating
thermostat, flame detection thermo-couple and maximum temperature control.
• Fluegassensor(DCF).• Designedtooperateonmethanegas
or LPG (nozzles included).• Operationwithoutelectricalconnec-
tions.• Electronicversion(EG/PE)available
upon request.
A B C D E G
mm mm mm mm mm mm
780 2165 2000 1730 1010 310
980 1975 1810 1470 900 340
1080 2025 1860 1470 900 340
1180 2255 2090 2000 960 340
1280 2475 2310 2150 960 340
Capacity Heat Output
Useful Power
Heat. time
∆t=50°C
Cont. flow rate ∆t=30°C
Max. qty. of flue gases
Fluegas
temp.
Methane consum-
ption
LPG consum-
ption
Max. operating
temp.
Max. operating
press.Net
WeightHydraulic
fittingsRecirculation
and discharge
Gas fitting
Ø Flue gas
discharge
l kW kW min l/min g/s °C m³/h g/h °C MPa kg KW-WW Z-E G F (mm)
26,7 22,9 92 10,9 23,2 136 2,70 1988 75 0,6 194 Rp 1 Rp 1 R ½ 140
34,8 29,9 98 14,3 31,1 135 3,60 2581 75 0,6 241 Rp 1 ¼ Rp 1 ¼ R ½ 160
34,8 30,2 115 14,3 31,1 135 3,60 2581 75 0,6 276 Rp 1 ¼ Rp 1 ¼ R ½ 160
34,8 29,6 180 14,1 31,1 135 3,60 2581 75 0,6 377 Rp 1 ¼ Rp 1 ¼ R ½ 160
34,8 30,2 225 14,3 31,1 135 3,60 2581 75 0,6 452 Rp 1 ¼ Rp 1 ¼ R ½ 160
Note: open-vented, natural draught B11BS / category II 2H3+
*Version with electronic ignition
4 4
eG/p 600
eG/p 800
eG/p 1000
eG/p 1500
eG/p 2000
Capacity
eG/p 600575
eG/pe 600*eG/p 800
800eG/pe 800*eG/p 1000
950eG/pe 1000*eG/p 1500
1450eG/pe 1500*eG/p 2000
1850eG/pe 2000*
GaS WaTeR HeaTeRwall-hung, storage open-vented
Z
E
C
A
DE
G
B
F
WW
KW
Floor-standing storage room-sealed and “fan flue” gas water heaters feature the most advanced technological solutions to solve the most challenging in-stallation problems. Their electronic controls makes them ideal for collective use (on campsites, in sports facilities and hotels, for example) and in industrial settings.
Fan flueSERIES 220-300-400
• Steeltank,glass-linedusingtheflow-coating method (850°C).
• Corrosion-proofmagnesiumanodewith anode control device.
• Verythickmineralwoolinsulationlayer.
• Externalcasingmadeofpre-paintedsheet metal.
• Electronicignitionwithflamedetection and ionisation flame control.
• Fluegasextractionfanwithsafetypressure switch.
• Triplesafetygasvalve:operatingthermostat, ionisation flame detection and maximum temperature control.
• Timerclock.• Storedwatertemperatureindicator.• Designedtooperateonmethanegas
or LPG (nozzles included).• Coaxialorsplitfluegasdischarge
available.
Accessories on page 46
Capacity Heat output
Useful Power
Heat. time ∆t=50°C
Cont. flow rate ∆t=30°C
Max. qty. of flue gases
Flue gas
temp.
Methane consum-
ption
LPG consum-
ption
Max. operating
temp.
Max. operating
press.Net
weightHydraulic
fittingsRecirculation
and discharge
Gas fitting
Ø Flue gas
discharge
l kW kW min l/min g/s °C m³/h g/h °C MPa kg KW-WW Z-E G F (mm)
26,7 24,1 33 11,5 16,8 172 2,82 2100 75 0,6 141 Rp 1 Rp 1 R ½ 100
30,6 27,1 29 14,6 16,7 162 3,25 2400 75 0,6 170 Rp 1 Rp 1 R ½ 100
30,6 27,1 29 14,6 17,3 157 3,25 2400 75 0,6 210 Rp 1 Rp 1 R ½ 100
Note: room-sealed, fan flue C12 C32 C42 C82 / category II 2H3+ / max absorbed power: 62W -230V~
A B C D E G
mm mm mm mm mm mm
640 1750 390 590 790 1150
640 1975 390 590 790 1375
690 2150 390 590 790 1540
4 5
Capacity
TF 220 220
TF 300 300
TF 400 390
TF 220
TF 300
TF 400
GaS WaTeR HeaTeRwall-hung, storage room-sealed
accessories & kit for gas water hearterCODE DESCRIPTION
FLUE SYSTEMS FOR GAS WATER HEATERSFAN FLUE TF 80-120
030341 COAXIALOUTLETKITØ60/28mm- 1 meter coaxial mouth - 1m 0 60/28 mm coaxial pipe discharge/suction end - wall cover roses
030342 Ø60/28mmcoaxialextensioncord– 0.5 meters
030343 60/28 mm coaxial extension cord – 1.0 meter
140214 90°Ø60/28mmcoaxialelbow
140324 Ø32/28mmSPLITOUTLETKIT- 1 meter n. 1 1 meter Ø 28 mm outlet extension cord n. 1 1 meter Ø 32 mm outlet extension cord discharge/suction end - wall cover roses
030344 Ø28mmoutletextensioncord – 0,5 meters
030363 Ø28mmoutletextensioncord – 1.0 meter
030364 Ø32mmsuctionextensioncord– 0.5 meters
030365 Ø32mmsuctionextensioncord – 1.0 meter
140210 90°Ø28mmoutletelbow
140211 45°Ø28mmoutletelbow
140212 90°Ø32mmsuctionelbow
FLUE SYSTEMS FOR GAS WATERHEATERSFAN FLUETF 220-300-400
140406 COAXIALOUTLETKITØ60/100mm-1 meter multi-directional 90° coaxial elbow with inspections, coaxial pipe and discharge/suction
140414 VerticalØ60/100mmflangedcoaxialstubpipe
140407 Ø60/100mmcoaxialextensioncord- 1.0 meter
140410 90°Ø60/100mmcoaxialelbow
140423 COAXIALOUTLETKITONROOFØ80/110mm- 1 meter coaxial pipe, flanged concentric 118-100 reduction, gasket, 80-60 reduction; device for roof outlet equipped with sleeve and fastening screws
140408 Ø80/-80mmSPLITOUTLETKIT- 1 meter formed by: splitter with condensation outlet and inspections, n.2 90° elbows, n.2 extension cords, suction/discharge
140409 v 80 mm extension cord - 1 meter
140411 90°Ø80mmelbow
4 6
GaS WaTeR HeaTeR
The “STReNGTHS” of the product range in detail:
4 7
The Styleboiler range of electric storage water heaters offers an extensive array of models for the production of domestic hot water (D.H.W.) with a ca-pacity ranging from 10 to 1000 litres and power ratings from 1.2 to 10 kW with single- and three-phase connections. The range meets both the domestic requirements of a typical home as well as those of industrial and collective settings. The product lines include “rapid” models, which are ideal for the rapid and cheap production of small quantities of water, “smart” models which are small water heaters designed for installations where limited space is avai-lable, the classic “standard” models devised to accommodate the essential basic requirements of the market, and also the “interline” product line, pro-viding a large number of combinations to meet the highest expectations as regards quality in observance of European and international standards.
Thermal insulationInsulation layer made of very thick (Interline range) high-density polyurethane (PU) foam that guarantees excellent insulation.
Tank protection against wearThanks to the “flow-coating” enamelling pro-cess at 850°C for guaranteed quality internal protection or via classic Teflon-coating.
Magnesium anodeFeatured in all the models in the range, this anode makes for effective electrochemical tank protection.
External Control Knob (SE)External control knob used to facilitate the waterheater temperatureadjustment,com-bined with the flange for easy inspection and cleaning.
Dual SafetyThanks to the presence of both an operating thermostat and a maximum temperature thermostat to avoid possible malfunctions.
IP Degree of ProtectionStyleboiler water heaters are safe because they are splash-proof and are specially desig-ned for installation close to the water delivery points, even in public and collective settings.
Environmentally friendlyWe strives to optimise its industrial activity while respecting the environment. To mini-mise the environmental impact of its pro-ducts, it has abolished the use of chlorofluo-rocarbons (CFC-HCFC) in the insulation (PU) layer and makes continuous efforts to use recyclable components.
electric Water Heaters
4 8
Capacity Power Voltage Heat. time Δt=50°C
Max. operating temp.
Max. operating press.
NetWeight
Hydraulic fittings A B C D E F G
l kW V~ min °C Mpa Kg KW-WW mm mm mm mm mm mm mm
pony 10/Se 10 1,2 230 30 75 0,8 6,0 R ½ 261 251 450 228 100 62 189
pony 10/Se s 10 1,2 230 30 75 0,8 6,0 R ½ 261 251 450 250 100 62 189
pony 15/Se 15 1,2 230 46 75 0,8 7,5 R ½ 296 285 498 248 100 69 216
pony 15/Se s 15 1,2 230 46 75 0,8 7,5 R ½ 296 285 498 270 100 69 216
pony 30/Se 30 1,2 230 92 75 0,8 10,0 R ½ 366 355 568 384 100 89 266
Note: s = undersink version
Capacity Power Voltage Heat. time Δt=50°C
Max. operating temp.
Max. operating press.
Net Weight
Hydraulic fittings A B C D E F G
l kW V~ min °C Mpa Kg KW-WW mm mm mm mm mm mm mm
pony 10 10 1,2 230 30 75 0,8 6,0 R ½ 261 251 450 228 100 62 189
pony 10 s 10 1,2 230 30 75 0,8 6,0 R ½ 261 251 450 250 100 62 189
pony 15 15 1,2 230 46 75 0,8 7,5 R ½ 296 285 498 248 100 69 216
pony 15 s 15 1,2 230 46 75 0,8 7,5 R ½ 296 285 498 270 100 69 216
pony 30 30 1,2 230 92 75 0,8 10 R ½ 366 355 568 384 100 89 266
Note: s = undersink version.
WWWK
E
C
AD
B
FG
W WK W
E
AC
D
B
FG
WWWK
E
C
A
D
B
FG
W WK W
E
A
C
D
B
FG
oversink version 10-15-30
undersink version10-15
WWWK
E
A
C
D
B
FG
WWWKE
C
A
D
B
FG
WWWK
E
A
C
D
B
FG
WWWKE
C
A
D
B
FG
oversink version 10-15-30 undersink version 10-15
Wall-hung electric storage water heaters are ideal for the rapid and cheap production of small quantities of water. They can be installed above or below the sink (30 Litres above only). The external control knob (SE) makesforeasieradjustmentofthewatertemperature.
Wall-hung electric storage water heaters are ideal for the rapid and cheap produc-tion of small quantities of water. They can be installed above or below the sink (30 Litres above only).
• Steeltank,glass-linedusingtheflow-coatingmethod (850°C).
• Tankinspectionflange.• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelementfitted
on a flange.• Regulationandsafetyrodthermostatwith
external control knob.• Polystyreneinsulatingshells(EPS)forreduced
heat loss.• Shock-resistantpolypropylene(PP)casing
and back.• Bracketsforwallmountingavailableupon
request.• LEDindicatorlight.• IPX5protectivecoveroverelectricalparts.
• Steeltank,glass-linedusingtheflow-coatingmethod (850°C).
• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelementfittedon
a 1 1⁄4 coupling.• Regulationandsafetyrodthermostat.• Polystyreneinsulatingshells(EPS)forreduced
heat loss.• Shock-resistantpolypropylene(PP)casing
and back.• Bracketsforwallmountingavailableuponrequest.• LEDindicator light.• IPX5protectivecoveroverelectricalparts.
Rapid SESERIES 10-15-30
RapidSERIES 10-15-30
external Control Knob
eLeCTRIC WaTeR HeaTeRSwall-hung, storage, installation above or below the sink
KW WW
450277
106,5
021
120
489
260
WKWW
100
368
072
358
115381
554
Wall-hung electric storage water hea-ters are ideal for the rapid and cheap production of small quantities of water where the installation space is limited.
Wall-hung electric storage water hea-ters are ideal for the rapid and cheap production of small quantities of water where the installation space is limited.
• Steeltanktreatedwiththermo-hardeningresins (Teflon) or glass-lined using the flow-coating method (850°C) depending on the model and/or version.
• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelementfitted
on a 1 1⁄4 coupling.• Regulationandsafetyrodthermostat.• CFCandHCFC-freepolyurethane(PU)
foam insulation layer.• Externalcasingmadeofsheetmetal
coated with epoxy powder paint.• LEDindicatorlight.• IPX3protectivecoveroverelectricalparts(IPX2forVB30).
• Storedwatertemperatureindicator.
• Steeltanktreatedwiththermo-hardeningresins (Teflon) or glass-lined using the flow-coating method (850°C) depending on the model and/or version.
• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelementfitted
on a 1 1⁄4 coupling.• Regulationandsafetyrodthermostat.• CFCandHCFC-freepolyurethane(PU)
foam insulation layer.• Externalcasingmadeofsheetmetal
coated with epoxy powder paint.• LEDindicatorlight.• IPX3protectivecoveroverelectricalparts(IPX2forVB30).
• Storedwatertemperatureindicator.
Power Voltage Heat. time Δt=50°C
Max. operating temp.
Max. operating press.
Net weight
Hydraulic fittings
l kW V~ min °C MPa kg KW-WW
1,2 230 77 75 0,8 12 R ½
Power Voltage Heat. time Δt=50°C
Max. operating temp.
Max. operating press.
Net weight
Hydraulic fittings
l kW V~ min °C MPa kg KW-WW
1,2 230 77 75 0,8 12 R ½
Power Voltage Heat. time Δt=50°C
Max. operating temp.
Max. operating press.
Net weight
Hydraulic fittings
l kW V~ min °C MPa kg KW-WW
1,2 230 92 75 0,8 12 R ½
Power Voltage Heat. time Δt=50°C
Max. operating temp.
Max. operating press.
Net weight
Hydraulic fittings
l kW V~ min °C MPa kg KW-WW
1,2 230 92 75 0,8 12 R ½
View from above
4 9
Capacity
VD 30 30
Capacity
VF 30 30
Capacity
VDO 30 25
Capacity
VFO 30 25
Standard miniSERIES 30
SmartSERIES 30
eLeCTRIC WaTeR HeaTeRSwall-hung, storage
WWKW
450
A
100
B
072
211
475
Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The water heaters are avai-lable in a vertical version, vertical universal left-right thermo version, horizon-tal version and horizontal thermo version.
• Steeltanktreatedwiththermo-hard-ening resins (Teflon) or glass-lined using the flow-coating method (850°C) depending on the model and/or version.
• Armouredcopperheatingelementfitted on a 1 1⁄4 coupling.
• Corrosion-proofmagnesiumanode.• Regulationandsafetyrodthermostat;• LEDindicatorlight.
• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.
• CFCandHCFC-freepolyurethane(PU)foam insulation layer.
• IPX4protectivecoveroverelectricalparts(IPX2forversionsV/T50-80-100).
• Storedwatertemperatureindicator.
Power Voltage Heat. time Δt=50°C
Max. operating temp.
Max. operating press.
Net weight
Hydraulic fittings A B
kW V~ min °C MPa kg KW-WW mm mm
1,2 230 153 75 0,8 15,1 R ½ 550 320
1,2 230 245 75 0,8 21,8 R ½ 780 550
1,2 230 306 75 0,8 25,5 R ½ 930 700
5 0
Capacity
l
VD 50 50
VD 80 80
VD 100 100
StandardSERIES 50-80-100
eLeCTRIC WaTeR HeaTeRSwall-hung, storage
WWKW
450
A
100
B072
211
475
WWKW
450A
100
B
072
211
475
054 574
B
A
001 211
072
KW WW
054 574
B
A
001 211
072
KW WW
Wall-hung electric storage water heaters are designed to meet the highest expectations as regards quality in observance of European and international standards. The insulation la-yer is made of very thick high-density polyure-thane (PU) foam to minimise heat loss.
Wall-hung electric storage water heaters are the basic product range devised to ca-ter for the most varied market require-ments. The external control knob (SE) ma-kes for easier adjustment of the watertemperature. Also recommended for in-dustrial and collective use. Also available in the thermo version.
• Steeltank,glass-linedusingtheflow-coatingmethod (850°C).
• Ø134 tank inspection flange.• Corrosion-proofmagnesiumanode.• Armoured copper heating element fitted on a flange.• Externalregulationandsafetycapillary
thermostat.• Externalcasingmadeofsheetmetalcoatedwith
epoxy powder paint.• CFCandHCFC-freeverythickpolyurethane(PU)
foam insulation layer.• LEDindicatorlight.• IPX5protectivecoveroverelectricalparts
complete with cable and plug.• Storedwatertemperatureindicator.
• Steeltank,glass-linedusingtheflow-coat-ing method (850°C).
• Ø88mmtankinspectionflange.• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelementfitted
on a flange.• Regulationandsafetyrodthermostatwith
external control knob.• CFCandHCFC-freepolyurethane(PU)foam
insulation layer.• IPX4protectivecoveroverelectricalparts.• Externalcasingmadeofsheetmetalcoated
with epoxy powder paint.• LEDindicatorlight.• Storedwatertemperatureindicator.
external Control Knob
Capacity Power Voltage Heat. time Δt=50°C
Max. oper. temp.
Max. oper. press.
Net Weight
Hydraulic fittings A B
l kW V~ min °C MPa kg KW-WW mm mm
1,2 230 153 75 0,8 15,5 R ½ 509 281
1,2 230 245 75 0,8 20,5 R ½ 729 498
1,2 230 306 75 0,8 25,5 R ½ 879 648
Capacity Power Voltage Heat. time. Δt=50°C
Insul. thickness
Heat loss 65°C
Max. oper. temp.
Max. oper. press.
Net weight
Hydraulic fittings A B
l kW V~ min mm kWh/24h °C MPa kg KW-WW mm mm
1,2 230 122 ≥25 0,78 75 0,8 18,5 R ½ 513 292
1,2 230 153 ≥25 0,87 75 0,8 21,0 R ½ 596 375
1,2 230 245 ≥25 1,13 75 0,8 27,0 R ½ 799 587
1,2 230 306 ≥25 1,30 75 0,8 33,0 R ½ 1013 801
Note: * = 1.5 and 2.0 kW heating element available
5 1
Capacity
VF 50 Se 50
VF 80 Se 80
VF 100 Se 100
Capacity
ISWV 40 40
ISWV 50 50
ISWV 80 80
ISWV 100 100
Standard topSERIES 40-50-80-100
Standard SESERIES 50-80-100
Note: * = 3.0 kW 230 and 400/3 V~ heating element available, in which case the external control knob SE is no longer required.
eLeCTRIC WaTeR HeaTeRSwall-hung vertical storage
193
B
450
072
100
A
476
112 230
244
B
134
540
156
A
455
WWKWWWKW
Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The external control knob (SE)makesforeasieradjustmentofthewatertemperature.Alsorecommen-ded for industrial and collective use. Also available in the thermo version.
• Steeltank,glass-linedusingtheflow-coating method (850°C).
• Ø88mmtankinspectionflange.• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelement
fitted on a flange.• Regulationandsafetyrodthermostat
with external control knob.• CFCandHCFC-freepolyurethane(PU)
foam insulation layer.
• IPX4protectivecoveroverelectricalparts.
• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.
• LEDindicatorlight.• Storedwatertemperatureindicator.
Accessories on page 60
external Control Knob
version 120 versions 150/200
Capacity Power Voltage Heat. timeΔt=50°C
Max. oper. temp.
Max. oper. press.
Net Weight
Hydraulic fittings A B
l kW V~ min °C MPa kg KW-WW mm mm
1,5 230 294 75 0,8 29,0 R ½ 1029 605
2,0* 230* 275 75 0,8 42,0 R ¾ 945 500
2,0* 230* 367 75 0,8 51,5 R ¾ 1205 800
Note: * = 3.0 kW 230 and 400/3 V~ heating element available, in which case the external control knob SE is no longer required.
5 2
Capacity
VF 120/ Se 120
VF 150/Se 150
VF 200/Se 200
Standard SESERIES 120-150-200
eLeCTRIC WaTeR HeaTeRSwall-hung, storage
WW KW
124
476
A
CD
B
100
270
450
PVPRPR
PV
Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The water heaters are avai-lable in a vertical version, vertical universal left-right thermo version, horizon-tal version and horizontal thermo version.
• Steeltanktreatedwiththermo-hard-ening resins (Teflon) or glass-lined using the flow-coating method (850°C) depending on the model and/or version.
• Armouredcopperheatingelementfitted on a 1 1⁄4 coupling.
• Corrosion-proofmagnesiumanode.• Regulationandsafetyrodthermostat.• LEDindicatorlight.
• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.
• CFCandHCFC-freepolyurethane(PU)foam insulation layer.
• IPX4protectivecoveroverelectricalparts(IPX2forversionsV/T50-80-100).
• Storedwatertemperatureindicator.
Capacity Power Voltage Heat. time. Δt=50°C
Max. oper. temp.
Max. oper. press.
Net weight
Hydraulic fittings
Coil fittings A B C D
l kW V~ min °C MPa kg KW-WW PV-PR mm mm mm mm
1,2 230 153 75 0,8 17,0 R ½ Rp ½ 548 319 229 132
1,2 230 245 75 0,8 23,5 R ½ Rp ½ 779 550 229 363
1,2 230 306 75 0,8 27,5 R ½ Rp ½ 930 701 229 363
5 3
Capacity
VF/T 50 DX/SX 50
VF/T 80 DX/SX 80
VF/T 100 DX/SX 100
Standard termoSERIES 50-80-100
eLeCTRIC WaTeR HeaTeRSwall-hung, storage
PV
PR
PV
PR
193
B
450
072
100
231
250
A
476
112
PV
PR
PV
PR
241
450
230
244
B
134
540
156
A
455
WWKWWWKW
external Control
Knob
Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The external control knob (SE)makesforeasieradjustmentofthewatertemperature.Alsorecommen-ded for industrial and collective use. Also available in the thermo version.
• Steeltank,glass-linedusingtheflow-coating method (850°C).
• Ø88mmtankinspectionflange.• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelement
fitted on a flange.• Regulationandsafetyrodthermostat
with external control knob.• CFCandHCFC-freepolyurethane(PU)
foam insulation layer.
• IPX4protectivecoveroverelectricalparts.
• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.
• LEDindicatorlight.• Storedwatertemperatureindicator
Accessories on page 60
version 120 versions 150/200
Power Voltage Heat. time Δt=50°C
Max. oper. temp.
Max. oper. press.
NetWeight
Hydraulic fittings
Coilfittings
Heat exchange surface
Power (Δt 35 K)**
D.H.W. produc(Δt 35 K)**
Primary flow rate A B
kW V~ min °C MPa kg KW-WW PV-PR m² kW I/h m³/h mm mm
1,5 230 294 75 0,8 37,0 R ½ Rp ½ 0,6 19,0 469 2,0 605 1029
2,0* 230* 275 75 0,8 56,5 R ¾ Rp ½ 0,9 33,0 810 2,0 945 500
2,0* 230* 367 75 0,8 66,0 R ¾ Rp ½ 0,9 33,0 810 2,0 1205 800
Note: * = 3.0 kW 230 and 400/3 V~ heating element available, without control knob **= primary circuit temperature 80°C / secondary circuit temp 10 /45°C / primary flow rate indicated in the table -D.H.W. = domestic hot water.
5 4
Capacity
l
VF/T 120/Se DX120
VF/T 120/Se SXVF/T 150/Se DX
150VF/T 150/Se SXVF/T 200/Se DX
200VF/T 200/Se SX
Standard termo SESERIES 120-150-200
eLeCTRIC WaTeR HeaTeRSwall-hung, storage
WWKW
PR
PVF
H
A B
C R
M L
D
E G S
WWKW
PR
PV
A B S
F
C R
L M
G
D
E
H
Electric water heaters with heat exchanger suitable for solar application, are the basic product range devised to cater the most varied market require-ments. Suitable for collective use.
• ArmoredcopperheatingelementfittedonaØ88mmflangewithsolarsensor sheath included.
• Steeltank,glass-linedusingtheflowcoating method (850° C).
• Corrosion-proofmagnesiumanode• Regulationandsafetyrodthermostat• Indicatorlight.• Externalcasingmadeofsteelsheet
metal coated with epoxy powder paint.
• CFCandHCFC-freepolyurethane(PU)foam insulation layer.
• IPX4protectivecoveroverelectricalparts.
• Storedwatertemperatureindicator• Availablewithleftorrighthydraulic
connections.• Increasedsizecoil.
Versions 60-120 Versions 150-200
newnewStandard with solar coilSERIES 80-100-120-150-200
Power Voltage Heating time (ΔT 50 °C)
Max. operating temperature
Max. operating pressure
Net weight
Hydraulic connections
Coilconnections
Heat Exchange surface
kW V~ min °C MPa kg KW-WW PV-PR m²
1,5 230 23’ 00” 95 0,8 28,5 Rp ½ R ½ 0,6
1,5 230 29’ 00” 95 0,8 33,5 Rp ½ R ½ 0,6
1,5 230 34’ 00” 95 0,8 37,0 Rp ½ R ½ 0,6
2,0 230 30’ 00” 95 0,8 56,0 R ¾ R ½ 0,9
2,0 230 40’ 00” 95 0,8 65,5 R ¾ R ½ 0,9
A B C D E F G H L M R S
mm mm mm mm mm mm mm mm mm mm mm mm
193 305 231 475 450 270 380 100 112 128 250 731
193 455 231 475 450 270 380 100 112 128 250 878,5
193 605 231 475 450 270 380 100 112 128 250 1028,5
243 500 241 555 540 431 486 230 156 118 450 945
243 800 241 555 540 431 486 230 156 118 450 1205
Note: version without heating element, upon request
5 5
VDT/S 80
VDT/S 100
VDT/S 120
VDT/S 150
VDT/S 200
Capacity
l
VDT/S 80 DX80
VDT/S 80 SXVDT/S 100 DX
100VDT/S 100 SXVDT/S 120 DX
120VDT/S 120 SXVDT/S 150 DX
150VDT/S 150 SXVDT/S 200 DX
200VDT/S 200 SX
eLeCTRIC WaTeR HeaTeRSwall-hung storage
337
241
481
WWKW
A
450
B
120 CD
BD C
481
450
A
570
450
120
A481
245
B
358
CD
WW
KWWWKW
BD C
481
450
A
570
450
120
A481
245
B
358
CD
WW
KWWWKW
Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The water heaters are avai-lable in a vertical version, vertical universal left-right thermo version, horizon-tal version and horizontal thermo version.
• Steeltanktreatedwiththermo-hard-ening resins (Teflon) or glass-lined using the flow-coating method (850°C) depending on the model and/or version.
• Armouredcopperheatingelementfitted on a 1 1⁄4 coupling.
• Corrosion-proofmagnesiumanode.• Regulationandsafetyrodthermostat.
• LEDindicatorlight.• Externalcasingmadeofsheetmetal
coated with epoxy powder paint.• CFCandHCFC-freepolyurethane(PU)
foam insulation layer.• IPX4protectivecoveroverelectricalparts(IPX2forversionsV/T50-80-100).
• Storedwatertemperatureindicator.
horizontal versions50-80-100
Power Voltage Heat. time Δt=50°C Max. oper. temp. Max. oper. press. Net Weight Hydraulic fittings A B C D
kW V~ min °C MPa kg KW-WW mm mm mm mm
1,2 230 245 75 0,8 20,5 R ½ 776 272 351 305
1,2 230 306 75 0,8 25,5 R ½ 926 422 380 426
Power Voltage Heat. time Δt=50°C Max. oper. temp. Max. oper. press. Net Weight Hydraulic fittings A B C D
kW V~ min °C MPa kg KW-WW mm mm mm mm
1,2 230 153 75 0,8 15,5 R ½ 545 120 189 236
1,2 230 245 75 0,8 20,5 R ½ 776 272 351 305
1,2 230 306 75 0,8 25,5 R ½ 926 422 380 426
1,2 230 367 75 0,8 29,0 R ½ 1058 520 444 494
2,0 230 275 75 0,8 65,5 R ¾ 1024 530 238 256
2,0 230 367 75 0,8 71,5 R ¾ 1294 800 238 256
Note: heating element fitting left or right.
versions 150/200
version 120
5 6
Capacity
l
OD 80 DX80
OD 80 SXOD 100 DX
100OD 100 SX
Capacity
l
OF 50 DX50
OF 50 SXOF 80 DX
80OF 80 SXOF 100 DX
100OF 100 SXOF 120 DX
120OF 120 SXOF 150 DX/SX 150
OF 200 DX/SX 200
Standard horizontalSERIES 50-80-100-200
eLeCTRIC WaTeR HeaTeRSwall-hung, horizontal storage
A
140
200
120
481
362
245
450
D
CB
PV
PR
WWKW
Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The water heaters are avai-lable in a vertical version, vertical universal left-right thermo version, horizon-tal version and horizontal thermo version.
• Steeltanktreatedwiththermo-hard-ening resins (Teflon) or glass-lined using the flow-coating method (850°C) depending on the model and/or version.
• Armouredcopperheatingelementfitted on a 1 1⁄4 coupling.
• Corrosion-proofmagnesiumanode.• Regulationandsafetyrodthermostat.
• LEDindicatorlight.• Externalcasingmadeofsheetmetal
coated with epoxy powder paint.• CFCandHCFC-freepolyurethane(PU)
foam insulation layer.• IPX4protectivecoveroverelectricalparts(IPX2forversionsV/T50-80-100).
• Storedwatertemperatureindicator.
Power Voltage Heat. time. Δt=50°C
Max. oper.temp
Max. oper. press
Net Weight
Hydraulic fittings
Coil fittings A B C D
kW V~ min °C MPa kg KW-WW PV-PR mm mm mm mm
1,2 230 245 75 0,8 26,5 R ½ Rp ½ 807 370,5 316,5 220
1,2 230 306 75 0,8 31,6 R ½ Rp ½ 930 418,5 391,5 370
5 7
Capacity
l
OF/T 80 DX80
OF/T 80 SX
OF/T 100 DX100
OF/T 100 SX
Standard horizontal termoSERIES 80-100
eLeCTRIC WaTeR HeaTeRSwall-hung, storage horizontal
Z
A B
DE
F
C
WW
KW
Floor-standing electric storage water heaters are designed to meet the hi-ghest expectations as regards quality in observance of European and interna-tional standards. The insulation layer is made of very thick high-density polyu-rethane (PU) foam to minimise heat loss. They are ideal for collective and industrial use.
• Steeltank,glass-linedusingtheflow-coating method (850°C).
• Ø134mmfrontinspectionhatch.• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelement
fitted on the hatch.• Regulationandsafetythermostat.• Externalcolouredplastic(PVC)
coating.
• CFCandHCFC-freeverythickpolyurethane (PU) foam insulation layer.
• IPX5protectivecoveroverelectricalparts.
• Storedwatertemperatureindicator.
Accessories on page 60
Capacity Power Voltage Heat. Time. Δt=50°C
Insul. thickness
Heat loss 65°C
Max. oper. temp.
Max. oper. press.
Net weight
Hydraulic fittings Recirculation A B C D E F
l kW V~ min mm kWh/24h °C MPa kg KW-WW Z mm mm mm mm mm mm
1,5 230 294 ≥50 1,50 75 1,0 38 Rp ¾ Rp ¾ 610 620 854 150 486 720
2,0 230 294 ≥50 1,70 75 1,0 46 Rp ¾ Rp ¾ 610 620 1056 150 551 922
2,0 230 367 ≥50 2,00 75 1,0 53 Rp ¾ Rp ¾ 610 620 1329 150 651 1195
3,0 230 367 ≥50 2,40 75 1,0 77 Rp 1 Rp 1 650 675 1560 148 828 1408
3,0 400/3 367 ≥50 2,40 75 1,0 77 Rp 1 Rp 1 650 675 1560 148 828 1408
4,0 400/3 367 ≥50 2,80 75 1,0 99 Rp 1 Rp 1 750 775 1553 162 782 1387
5,0 400/3 367 ≥50 3,30 75 1,0 115 Rp 1 Rp 1 750 775 1818 162 932 1652
5,0 400/3 440 ≥50 3,60 75 1,0 176 Rp 1 Rp 1 810 832 1819 124 871 1659
5 8
Capacity
l
ISS 120 120
ISS 160 160
ISS 200 200
ISS 300 300
ISS 300/3 300
ISS 400/3 400
ISS 500/3 500
ISS 600/3 600
InterlineSERIES 120-160-200-300-400-500-600
eLeCTRIC WaTeR HeaTeRSfloor-standing, storage
KW
Z
WW
D
E
F
C
A B
• Glass-linedsteelboiler.• DoubleØ134mmfronthatchwayfor
electrical Kit assembly and inspection.• Ø134mmtopbottom-flange
complete with counter-flange.• Verythickexpandedpolyurethane
(PU) / (EPS) insulation layer. “Easy entry” system.
• Externalcolouredplasticcoating.• Adjustablefeetforfloorstanding.• Storedwatertemperatureindicator
Accessories on page 60
Floor-standing electric storage water heaters are designed to meet the new expectations of the market as to durability and great storage. To this end, this new high-capacity product line was introduced, providing maximum quality and durability owing to the use of special materials and sophisticated techno-logical solutions. The guarantee of durability in time is further extended by means of a modern “glass-lining” treatment over the tank. The insulation layer is manufactured by means of a new system that combines the technology of theinjectedpolyurethane(PU)withtheflexibilityofNEOPOR(EPS).Thissolu-tion allows the installer to have a “plug and play” product and, in case of need, it is an easy solution for making the product pass through openings whose width equals 800 mm. This system allows a trouble-free disassembly and re-assembly of the insulation layer for an easier installation in boiler rooms. The two big front hatchways characterise the line of these products and make them flexible and suitable for several combinations of electrical powers up to maximum 20 kW. The electrical components are supplied apart in handy sin-gle- and three-phase KITs with Incoloy 800 stainless steel heating elements with powers up to 10 kW or made of copper up to 5 kW. Furthermore, you can equip the tank with spiroid exchangers, if any, which can be installed in the hatchways. They are recommended for collective use.
INOX Stainless Steel Heating element KIT
Capacity Insul. thickness
Max. oper. temp.
Max. oper. press.
Net Weight
Hydraulicfittings Recirculation A B C D E F
l mm °C MPa kg KW-WW Z mm mm mm mm mm mm
>100 75 1,0 146 Rp 1 ¼ Rp 1 ¼ 880 925 1865 191 1071 1676
>100 75 1,0 170 Rp 1 ¼ Rp 1 ¼ 880 925 2245 191 1263 2056
5 9
Capacity
l
ISS 800 800
ISS 1000 1000
Interlinehigh storageSERIES 800-1000
eLeCTRIC WaTeR HeaTeRSstorage type, floor-standing
accessories & kit for electric water heatersCODe DeSCRIpTION
070513 SINGLE-, THREE-PHASE TRANSFORMATION ELECTTRICAL KITONLY FOR SERIES V E V/T 150-200formedby:2”heatingelement-3.0kw-400/3V~installedontheflange, flange gasket, three-phase thermostat and closing cover.
070265 2.0 kW 230 V~ 1” SINGLE-PHASE ELECTRICAL KIT formed by: counter-flange with 1” sleeve, gasket, copper armoured heating element and thermostat.
070266 3.0 kW 230 V~ 1” SINGLE-PHASE ELECTRICAL KIT formed by: counter-flange with 1” sleeve, gasket, copper armoured heating element and thermostat
070267 3.0 kW 400/3 V~ 2” THREE-PHASE ELECTRICAL KITformed by: counter-flange with 2” sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectorsNot suitable for 800 L and 1000 L models.
070268 4.0 kW 400/3 V~ 2” THREE-PHASE ELECTRICAL KIT~ formed by: counter-flange with 2” sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectorsNot suitable for 800 L and 1000 L models
070269 5.0 kW 400/3 V~ 2” THREE-PHASE ELECTRICAL KIT formed by: counter-flange with 2” sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectorsNot suitable for 800 L and 1000 L models
070137 3,0÷6,0 kW 400/3 V~ THREE-PHASE INOX ELECTRICAL KIT formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket RECOMMENDED FOR SERIES 400-500-600-800-1000
070138 4.0÷8.0 kW 400/3 V~ THREE-PHASE INOX ELECTRICAL KIT formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. RECOMMENDED FOR SERIES 400-500-600-800-1000
070136 5.0÷10.0 kW 400/3V~ THREE-PHASE INOX ELECTRICAL KIT formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. RECOMMENDED FOR SERIES 400-500-600-800-1000
030528 SPIROID EXCHANGER KIT 1.0 sqmFOR ALL SERIES formed by: counter-flange, finned coil made of tinned copper 1 sqm; gasket, union set, round grill, fastening screws and nuts
030525 SPIROID EXCHAGER KIT 1.8 sqm ONLY FOR SERIES 400-500-600-800-1000formed by: counter-flange, finned coil made of tinned copper 1.8 sqm; gasket, union set, round grill, fastening screws and nuts
6 0
STANDARD
INTERLINE
INTERLINE
FREE STANDING
INTERLINE
eLeCTRIC WaTeR HeaTeRS
Thermal insulationInsulation layer made of very thick (range for collective use) high-density polyurethane (PU) foam that guarantees excellent insula-tion.
Tank protection against wearThanks to the “flow-coating” enamelling pro-cess at 850°C for guaranteed quality internal protection or via classic hot galvanising process(forseries600-2000only).
Magnesium anodeFeatured in all the models in the range, this anode makes for effective electrochemical tank protection.
Environmentally friendlyWe strive to optimise its industrial activity while respecting the environment. To mini-mise the environmental impact of its pro-ducts, it has abolished the use of chlorofluo-rocarbons (CFC-HCFC) in the insulation layer and makes continuous efforts to use recycla-ble components.
The “STReNGTHS” of the product range in detail:
6 1
We have come up with an appliance that fully exploits the natural energy released by a fuel deemed to be “poor”, namely wood, turning it into a precious source of energy that is easily exploited. Using a Styleboiler wood-fired water heater, alone or combined with an electric heating element, means having heat available at a low cost and in an environmentally-friendly way. The models available are devised for a prevalently domestic use, with a design marked by eco-friendly choices to help protect the environment. In fact, wood as a resource is a renewable and eco-compatible energy source. Our choice of wood as the fuel, which affects several sectors of the eco-nomy such as forestry and agriculture, which have the possibility of recovering millions of hectares of abandoned and deteriorated land, automatically makes for a sustainable development with the expan-sion of woodland crops. TheADVANTAGESofthissystementailthepossibilityofusingrenew-able natural resources, with the maximum practicality at limited costs, all this with a straightforward installation process that requires no elec-trical connections.
Wood-fired water heaters
98100 28
063
1468
WW KW WW KW
VP
RP
2898
100063
1468
613
450
Wood-fired
“Wood-fired” storage water heaters are designed to produce water where tra-ditional sources of energy are unavailable or simply to use renewable forms of energy while respecting the environment. Electric or thermo-electric versions are available.
• Steeltank,glass-linedusingtheflow-coating method (850°C).
• Corrosion-proofmagnesiumanode.• Combustionchambermadeof
refractory material with pull-out ash collecting device.
• Enamelledsheetmetalexternalcombustion chamber coating.
• Mineralwoolinsulationlayerforreduced heat loss.
• Armouredcopperheatingelement,regulation and safety rod thermostat (wood-electric version only).
• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.
• Storedwatertemperatureindicator.• Electricandthermo-electricversions
available.
Wood-fired / wood-electric version Wood-fired / wood-thermoelectric version
Capacity Power Voltage Heat. time Δt=50°C
Max. operating temp.
Max. operating press.
Net Weight Hydraulic fittings Coil
fittings
l kW V~ min °C MPa kg KW-WW PV-PR
- - - 90 0,8 46 R ½ -
1,2 230 245 90 0,8 46 R ½ -
1,2 230 245 90 0,8 49 R ½ Rp ¾
6 2
Capacity
l
LG 80
LGe 80
LGe/T 80
Note: LG = wood-fired version / LGE = wood-electric version / LGE/T = thermo-electric wood version
WOOD-FIReD WaTeR HeaTeR
General remarks
6 3
Styleboiler is in a position to boast a consolidated experience in the challenging world of protective coatings for steel tanks devised to store domestic hot water, thanks to over twenty years of doing business in the design and manufacture of storage water heaters for the production of hot water.
The range Styleboiler offers an extensive range of electric, gas and wood-fired storage water heaters and indirect cylinders to cater for all hot water requirements, both at home as well as in industrial or communal settings. The classical product range including boilers manufactured with glass-lined steel has been joined by a renewed and complete product line, which includes stainless steel boilers. The company’s policy, which aims at implementing technologies that do not affect the ecosystem, has led to the design and manufacture of new models that utilise renewable energy sources, such as “heat pumps”. Owing to this wide range of models, Styleboiler can cover a spectrum of capacities ranging from 10 to over 2.000 litres to guarantee the maximum comfort and well-being of end users.
Quality, safety and flexibilityStyleboiler has always stood for quality; the excellent quality of Styleboiler products is the result of an accurate design process combined with the use of advanced technologies, of carefully selected raw materials, and it is guaranteed by regular checks carried out at every stage of the manufacturing process. Product safety is guaranteed by the observance of applicable laws and product standards, along with the prestigious ISO 9001/2000 certification, which enable Styleboiler to accommodate the needs of the most demanding international markets. Flexibility is another feature that makes Styleboiler the best possible partner for its strong focus on the partnership with its customers, offering customised solutions wherever required.
All STYLEBOILER appliances conform to European Di-rectives. The gas appliances are devised and specifical-ly approved for the use of
standard fuels. All STYLEBOILER appliances made at the S.Maria di Zevio (VR) plant are designed and built in compliance with international quality standards ISO 9001/2000 and conform to article 3.3 of European Directive 97/23/EEC (PED).
Installation and use These appliances are approved for indoor installation only. Installation must be per-formed and certified by authorised techni-cians only, in accordance with the law. A “hydraulic safety group” compliant with EN 1487 or the equivalent must be fitted on all appliances. The water tempera-ture adjustment allows the energy con-sumption to be optimised according to the well-being required. However, it is advisable to prevent the temperature of the water stored from being too low, in order to avoid the prolife-ration of bacteria that cause Legionnaire’s disease. To this end, here are a few general precautions to take: • Keepthehotwaterinsidetheapplian-ce at a temperature of no less than 50 °C;• In the event of prolonged absen-ces, allow water to run freely from taps and showers for a few minutes;• Keepshowerheadsandtapsfreeofli-mescale build-ups. The manufacturer will not be held liable in the event of uses other than those speci-fied.
Technical characteristicsAs STYLEBOILER constantly strives to im-prove its products, the company reserves the right to make changes to the technical characteristics and to discontinue models illustrated in this catalogue without prior notice. The details are purely indicative and are included to help you choose the right ap-pliance for your needs. In addition, the ma-nufacturer denies all responsibility in the event of printing or transcription errors.
GuaranteeSTYLEBOILER guarantees the correct ope-ration of its appliances according to the methods stated on the guarantee certi-ficates included with the appliances and always in compliance with the applicable Laws in force.
Gruppo Giona S.p.A.
Via Apollo 11, 1 - 37059 S. Maria di Zevio (Verona) - Italy
tel. +39 045 6050099 r.a. - fax +39 045 6050124
www.styleboiler.it
Production site:
Via Apollo 11, 137059 S. Maria di Zevio (Verona) - Italy
Loc. Oliero di Sotto36020 Valstagna (Vicenza) - Italy
Via C. Grazioli 27/A29012 Caorso (Piacenza) - Italy
Internal boiler protection treatments:
ZIAC S.p.A.Loc. Speranza37059 S. Maria di Zevio (Verona) - Italy
Branches:
Styleboiler AG/SA/LTDNordweg 16 - Chemin du nord 1602502 Biel/Bienne - Switzerland
Style System Technik GmbhLeinenweberstraße, 8 48317 Drensteinfurt - Germany
Italian technology and quality
03-201
1IN
GLESE
ww
w.s
tudi
ocam
elot
.it