64
Italian technology and quality GENERAL CATALOGUE Heat pumps - Inertial puffers - Indirect cylinders - Water Heaters

Style Boiler

Embed Size (px)

DESCRIPTION

Heat pumps - Inertial puffers - Indirect cylinders - Water Heaters

Citation preview

Page 1: Style Boiler

Italian technology and quality

GENERAL CATALOGUE

Heat pumps - Inertial puffers - Indirect cylinders - Water Heaters

Page 2: Style Boiler

Heat pumps 4> wall-hung series 80-100 5

> floor standing series 180-300 6

> floor standing with coil series 300 8

> accessories & kit for heat pump 10

Inox 11> wall-mount electric water-heaters rapid series 10 12

> vertical wall-mount electric water heaters series 65 13

> vertical wall-mount electric water heaters series 50-80-100 13

> floor standing electric water heaters series 120-160-200-300-400-500 14

> floor standing electric water-heaters high storage series 800-1000 15

> indirect cylinders single and double coil series 120-160-200-300-400-500 16

> indirect cylinders single and double coil high storage series 800-1000 18

> accessories & kit for inox 20

Indirect cylinders 21> circular undermount series 115-150 22

> rectangular undermount series 120-160 23

> elliptical increased size coil series 300-400-500 24

> single and double coil series 120-160-200-300-400-500-600 26

> single and double coil high storage series 800-1000 28

> multiposition series 80-100-115-150-200-300 30

> accessories & kit for indirect cylinder 31

Inertial puffers 33> puffer series 200-300-400-500-600-800-1000 34

> tank in tank series 600-750-900 36

Contents

2

Page 3: Style Boiler

Contents

Gas water heater 39> wall-hung natural draught series 50-80-100-120 40

> wall-hung Fan flue series 80-120 41

> floor standing natural draught small storage series 115-150-200 42

> floor standing natural draught medium storage series 300-500 43

> floor standing natural draught high storage series 600-800-1000-1500-2000 44

> floor standing fan flue series 220-300-400 45

> accessories & kit for gas water heaters 46

Electric water heaters 47> wall-hung rapid series 10-15-30 48

> wall-hung round series 30 49

> wall-hung mini vertical series 30 49

> wall-hung vertical series 50-80-100 50

> wall-hung high storage series 120-150-200 52

> wall-hung thermoelectric series 50-80-100 53

> wall-hung thermoelectric high storage series 120-150-200 54

> wall-hung thermoelectric with increased size coil series 60-80-100-120-150-200 55

> wall-hung horizontal series 50-80-100 56

> wall-hung horizontal high storage series 120-150-200 56

> wall-hung horizontal thermoelectric series 80-100 57

> floor standing series 120-160-200-300-400-500-600 58

> floor standing high storage series 800-1000 59

> accessories & kit for electric water heaters 60

Wood-fired water heaters 61> floor standing series 80 62

3

Page 4: Style Boiler

The SystemThe heart of the “System” is an indirect cylinder with a built-in heat pump that enables the simultaneous or selective use of up to four different energy sources:1) thermal energy;2) electricity;3) solar power;4) environmental energy.The heat pump is designed to transfer heat from a body at a lower temperature to another body at a higher temperature. This process is the opposite of what happens in nature, and is due to the fact that electricity is supplied to the appliance that “heat pumps”.The operating principle of the heat pump is a thermodynamic cycle opposite to refrigeration. The efficiency of a heat pump is represented by its performance coefficient COP, which is the ratio of the heat output yielded to the electrical power utilised.

Operating principleThe heat pump comprises a closed circuit made up of a compressor, a condenser, a lamina-tion valve and an evaporator through which the heat transfer fluid flows. The thermodynamic cycle the fluid experiences consists in an adiabatic compression, a condensation phase, an expansion phase and also evaporation. During compression, the pressure and temperature of the fluid rise, during the second stage the fluid flows through a heat exchanger (condenser) where it comes into contact with domestic water, to which it yields heat. During the third stage, the fluid flows through an expansion valve (lamination process) and its pressure and temperature consequently drop. During the last stage, referred to as evapo-ration, the fluid switches from its liquid state to gas: the coolant is at very low temperatures, which enable it to absorb heat from the external heat transfer fluid. So during the operation of the heat pump, the following occurs: electricity is consumed in the compressor, heat is absor-bed from the external environment (evaporator) and heat is yielded in the condenser to the liquid that needs to be heated. The advantage of a heat pump lies in the fact that more energy is supplied in the form of heat than the electricity required for its operation.

The strengthsThe features that make this system worthwhi-le are multiple, but the most obvious advan-tage is that it is an intrinsically efficient system. It has direct repercussions on the amortisation of the installation cost and on the consumer’s utility bills too. Moreover, using a heat pump enables the exploitation of portions of energy which would otherwise be wasted (such as in installations in boiler rooms). Lastly, this system also provides an easy and convenient integration with other renewable energy sources (solar panels, wo-od-fired boilers, etc.). Heat pumps are ideally installed in cellars or damp rooms because the humidity in the air is removed during operation (dehumidifying effect).

EVAPORATORAbsorption of heat

from the outside

2/3 of energy

CONDENSERYielding of heat

to the domestic water

3/3 of energy

LAMINATION VALVE

ELECTRICITY SUPPLY

1/3 of energyEvaporator

Honeycomb grid

EBM axial fan

Support and drip water basin

Control panel

FilterThermostat-

controlled valveDanfoss

Compressor

4

Heat pumps

Page 5: Style Boiler

WWKW

B20

660

544

A

470�

100

431

112

480

FuturaSERIES 80-100

Compact system for heating sanitary water by using an air-to-water heat pump. The system utilises renewable energy. It is one of the most interesting products to be used for decreasing the fuel consumption and protecting the environment. Thanks to its small dimensions, equal to a normal water heater, and to its easy installation, the new heat pump (from 80L to 120L) is intended for domestic use. Just plug it in, like a normal water heater, and it is ready.

• Steel tank, glass-lined using the flow-coating method (850 °C).

• Corrosion-proof magnesium anode.• External casing made of sheet metal

coated with (white) epoxy powder paint.

• CFC and HCFC-free, 37 mm average polyurethane (PU) foam insulation layer.

• Hydraulic connections located in the lower part.

• Brackets for wall-mounting.

• 1,2 kW integrated electric heating element.

• Electronic control panel with display indicating temperature, indicator light for heat pump operation and electric resistance. Switch to activate the different modes of operation: Turbo, Bath, Comfort.

• Ecological refrigerant fluid R134a;• Rotary compressor for maximum

noiseless• Axial fan• Powerful fin type evaporator.

Capacity Power supply Refrigerant fluid/ average load

Average absorption (Heat pump only)

Electric heating element (water)

Electric heating element (air heating)

Maximum nominal absorption

V~/Hz/A -/kg kW kW kW kW230/50/16 R134a/0,28 0,31 1,20 0,90 2,41

230/50/16 R134a/0,28 0,31 1,20 0,90 2,41

Maximum temperature (heat pump only)

Maximum temperature (with electric heating element)

Maximum operating pressure

Net weight

Hydraulic connections A B

°C °C MPa kg KW-WW mm mm56 65 0,80 50 R 1/2 1142 392

56 65 0,80 56 R 1/2 1355 605

Series 80-100Heat PumP

newnew

Same connections of traditional water heaters

Easy installation

Canalization and masonry work not required

Save up to 70% of electricity

5

Capacity

lFutura ST 080 80

Futura ST 100 100

Futura ST 080Futura ST 100

wall-hung HeaT pump

Page 6: Style Boiler

Heat pumpsSERIES 180-300

Domestic water heating system with air-water heat pump. The system envisages the use of renewable energy and the possible integration with other energy sources such as electricity. Recommended for domestic and collective use.

• Steeltank,glass-linedusingtheflow-coating method (850 °C).

• Ø134mmfrontinspectionhatchintegrated with tinned copper condenser.

• Corrosion-proofmagnesiumanode.• Hydraulicconnectionslocated

on the rear.• CFCandHCFC-freeverythick

polyurethane (PU) foam insulation layer.

• Externalplastic(PVC)coating.• Adjustablefeetforfloorstanding.

• Environmentally-friendlygasR134a.• 1.5kW230V~electricheatingelement.• Controlpanelcompletewithswitch

with indicator light for heat pump and heating element operation, regulation thermostat, thermometer and signal indicators.

• Highandlowpressuresafetydevices.• DANFOSScompressorforsupersilent

operation.• EBM650m3/h axial fan.

Accessories on page 10

Capacity Power supply

Coolant/ average recharge

Absorption (heat pump only)*

Max. nominal absorption

Power output (heat pump only)*

Electric heating elem ent (integration)

l V~/Hz/A -/kg kW kW kW kW230/50/16 R134a/0,85 0,62 2,12 1,91 1,50

230/50/16 R134a/0,85 0,62 2,12 1,98 1,50

Maximum power output

Range of hot water temp. setting

Range of use

Maximum noise level

Max.temperature (heat pump only)

Max.temperature (with electric heating element)

Max. operating pressure

Net weight

Hydraulic fittings

Recirculation fittings

kW °C °C dB (A) °C °C MPa kg KW-WW Z3,41 29÷56 8÷35 61 55 65 1,0 95 Rp 1 Rp 1

3,48 29÷56 8÷35 61 55 65 1,0 109 Rp 1 Rp 1

Note: ** primary circuit temperature 80°C / secondary circuit temp. 10/45 °C

Data compliant with eN 255-3 (WpZ B-002-04-07 Wärmepumpentestzentrum NTB - FWS CH-Buchs)*

Coefficientof performance

Max. qty individual flow rate at 40 °C V max

Max. actual powerabsorbed Pes

Heating time th C D E F

COPt

I W h:min mm mm mm mm3,1 283 36 4:56 1412 142 612 9223,2 448 44 7:57 1852 142 912 1362

Note: * Room air temp. 15°C, humidity 71%, domestic water at 15° C / temperature in storage tank 55° C

Series 180-300Heat PumPs

6

Capacity

Hp 180 180

Hp 300 300

Hp 180Hp 300

Hp 180Hp 300

HeaT pumpstand alone

Page 7: Style Boiler

Z

D

E

F

713

C

650

WW

KW

Z

D

E

F

713

C

650

WW

KW

7

HeaT pump

Page 8: Style Boiler

Heat pumpsSERIES 300

Domestic water heating system with air-water heat pump. The system envisa-ges the use of renewable energy and the possible integration with other ener-gy sources such as electricity, thermal energy and solar power. Recommended for domestic and collective use.

• Steeltank,glass-linedusing the flow-coating method (850 °C).

• Ø134mmfrontinspection hatch integrated with tinned copper condenser.

• Singlecoil(forWversion)and double coil (for WW version), optimised for maximum heat exchange and minimum limescale build-up.

• Sensorfittings, (one for W version) (two for WW version).

• Corrosion-proofmagnesium anode.

• Hydraulicconnectionslocated on the rear.

• CFCandHCFC-freeverythick polyurethane (PU) foam insulation layer.

• Externalplastic(PVC)coating.

• Adjustablefeetforfloorstanding.

• Environmentally-friendlygas R 134a.

• 1.5kW230V~electricheating element.

• Controlpanelcompletewith switch with indicator light for heat pump and heating element operation, regulation thermostat, thermometer and signal indicators.

• Highandlowpressuresafety devices.

• DANFOSScompressorfor super silent operation.

• EBM650m3/haxialfan.

Accessories on page 10

Power supply

Coolant/average recharge

Absorption (heat pump only)*

Max. nominal absorption

Power output (heat pump only)*

Electric heating element (integration)

Maximum power output

Range of hot water temp. setting

Range of use

V~/Hz/A -/kg kW kW kW kW kW °C °C230/50/16 R134a/0,85 0,62 2,12 1,91 1,50 3,41 29÷56 8÷35

230/50/16 R134a/0,85 0,62 2,12 1,91 1,50 3,41 29÷57 8÷35

Data compliant with eN 255-3 (WpZ B-002-04-07 Wärmepumpentestzentrum NTB - FWS CH-Buchs)*

Coefficientof performance

Max. qty individual flow rate at 40 °C V max

Max. actual powerabsorbed Pes

Heating time th C D E F

COPt

I W h:min mm mm mm mm3,2 430 43 7:51 See diagram

3,1 430 55 8:01 See diagram

Note: * room air temp. 15 °C, 71% humidity, domestic water at 15 °C / temperature in storage tank 55 °C

Maximum noise level

top/bot. coil surface

Heat output (∆T 35 K)** top/bot.

Primary flow rate

Max. temperature (heat pump only)

Max. temperature (with electric heating element)

Max. operating pressure

Net weight

Hydraulic fittings

Exchanger fittings

Recirculation fittings

Number of sensors

dB (A) m² kW m³/h °C °C MPa kg KW-WW PV-PR Z Tr61 1,30/- 37/- 2,50 55 65 1,0 130 Rp 1 Rp 1 Rp 1 1

61 1,30/0,80 37/26 2,50 55 65 1,0 145 Rp 1 Rp 1 Rp 1 2

Note: * primary circuit temperature 80 °C / secondary circuit temp. 10 /45 °C.

1-2 Coil

8

Capacity

l

Hp 300 W 300

Hp 300 WW 300

Hp 300 WHp 300 WW

Hp 300 WHp 300 WW

HeaT pumpfixed single and double coil

Page 9: Style Boiler

KW

Z

WW

PV

PR Tr Tr

14230

284

2108613

62

65018

52713

Tr

Tr

Tr

Tr

WW

Z

PV2

PV1PR2

PR1KW

14230

284

2960

108612

121362

650

1852

713

KW

Z

WW

PV

PR Tr Tr

14230

284

2108613

62

650

1852

713

300 WW

300 W 300 W

300 WW

9

HeaT pump

Page 10: Style Boiler

accessories & kit for heat pumps

CODE DESCRIPTION

145053 AIR DELIVERY KIT The kit includes: black PST air conveyor, conveyor fastening system, aluminium rings

forØ160mmpipefastening,instructions,package.

145066 AIR SUCTION KIT The kit includes: black PST air conveyor, conveyor fastening system,

aluminiumringsforØ160mmpipefastening,instructions,package.

KIT diagram

Suction Delivery

Suction KIT Delivery KIT

1 0

HeaT pump

Page 11: Style Boiler

The “STReNGTHS” of the product range in detail:

1 1

Thanks to its range including electric storage water heaters and stainless steel indirect cylinders, STYLEBOILER offers complete solutions for the pro-duction of hot water with a capacity included between 10 and 1000 litres and powers included between 1.2 and 10 kW with single and three-phase connections.The range meets the domestic needs, but it can also be suitable for commu-nal settings. The product lines range from the “small” line, which is ideal for producing small quantities of water in a rapid and cheap way, to the “easy” medium-size water heaters, up to the “extra” line, which supplies the most advanced technology to be found on the market.“Interline” and “Free Standing” lines are the best way to meet the needs of huge quantities of hot domestic water and also meet the highest quality ex-pectations in compliance with European and international standards.

InoxThe “inox” (stainless steel) product line has been created to meet the new expectations as to durability and perfection. This line provides maximum quality and durability owing to the use of special materials such as stainless steel and sophisticated technologi-cal solutions, such as “TIG” and “Microplasma” welding.

Thermal insulation layerIt is manufactured with very thick and high-density polyurethane foam (PU) (Interline range) to assure excellent thermal insulation.

Magnesium anodeIt is to be found in all products within the range and makes the boiler’s electrochemical protection constantly effective.

Correx® corrosion-proof active protectionThe Correx® system is the latest technology in terms of active tank protection, and is fitted with a PCB, a control LED and a transmitted current titanium anode. This system solves all your anode-replacement and limescale removal problems.

Double safetyIt is achieved by using an operation thermo-stat and an over-temperature thermostat to prevent possible malfunctions.

IP protection levelStyleboiler’s water heaters are safe because theystandwaterjetsandcanbeinstalledclo-se to the supply points, also in public spaces and communities.

Respect of the environmentStyleboiler undertakes streamlining the in-dustrial activities in the respect of the envi-ronment. In order to reduce the environmen-tal impact to the minimum, it eliminated the hydrofluorocarbons (CFC-HCFC) from the insulation (PU) layer and always pays great attention to the recyclability of the compo-nents.

Line Inox

Page 12: Style Boiler

WWWK

100

450

261

228

251

62189

W WK W

100

261

450

250

251

62189

• AISI316Lstainlesssteelboiler,welded with “TIG” and “Microplasma” technology.

• AISI321stainlesssteelheatingelement.

• Corrosion-proofmagnesiumanode.• Stemsafetyandadjustment

thermostat. • Insulationlayerwithpolystyrene(EPS)

shells to minimise heat loss.

• Shellandbackmadewithshock-resistant polypropylene (PP).

• Wall-mountbyusingthespecificbrackets.

• Indicatorlight.• IPX5protectivecoverover

electrical parts.• Nylondielectriccircuitbreakers

on the hydraulic fittings.

Wall-mounted electric storage water heaters are designed for producing small quantities of water in a rapid and cheap way, as well as to meet the new ex-pectations as to durability and perfection. The “inox” stainless steel product line has been created for this purpose; this line supplies maximum quality and durability thanks to the use of special ma-terials, such as stainless steel and sophisticated technological solutions, such as “TIG” and “Microplasma” welding.They can be installed above and under the sink.

oversink version 10 undersink version 10

Capacity Power Voltage Heat. time Δt=50°CMax. oper.

temp.Max. oper.

press.Net

Weight Hydraulic

fittings

l kW V~ min °C MPa kg KW-WW

1,2 230 30 75 0,8 4,6 R ½

1,2 230 30 75 0,8 4,6 R ½

Note: s = undersink version. .

1 2

Capacity

l

pony 10X 10

pony 10X s 10

Small inoxSERIES 10

eLeCTRIC WaTeR HeaTeRSstorage-type, wall-mount above and under the sink

Page 13: Style Boiler

WWKW

450

648

100

424

072

211

475

WWKW

450648

100

424

072

211

475

054 574

B

A

001 211

072

WWKW

054 574

B

A

001 211

072

WWKW

Stainless steel wall-hung electric storage water heaters are designed to meet the new expec-tations as to durability and perfection. To this end, the “inox” (stainless steel) product line was introduced, providing maximum quality and durability owing to the use of special materials such as stainless steel and sophisticated technological solutions such as “TIG” and “Mi-croplasma” welding.

The wall-mounted electric storage wa-ter heater represents the basic range that combines great functionality, high efficiency and maximum quality.

• Aisi316Lstainlesssteeltankweldedwith“TIG” and “Microplasma” technology.

• Tankinspectionflange.• “Correx®”electronicprotectiondevice

with titanium anode and signalling LED.• Incoloy800stainlesssteelheating

element fitted on a flange.• Externalregulationandsafetycapillary

thermostat.• LEDindicatorlight.• CFCandHCFC-freeverythickpolyurethane(PU)

foam insulation layer.• Externalcasingmadeofsheetmetalcoated

with epoxy powder paint.• IPX5protectivecoveroverelectricalparts

complete with cable and plug.• Storedwatertemperatureindicator.• Nylondielectriccircuitbreakersonthehydraulic

fittings.

• AISI316Lstainlesssteelboiler, welded with “TIG” and “Microplasma” technology.

• Corrosion-proofmagnesiumanode.• AISI321stainlesssteelthreadedheating

element on 1” sleeve.• Capillarysafetyandinternalregulation

thermostat.• Indicatorlight.• CFCandHCFC-free,verythickexpanded

polyurethane (PU) insulation layer.• Externalcasingmadeofsheetmetalcoated

with epoxy powder paint.• IPX5protectivecoveroverelectricalparts.• Storedwatertemperatureindicator.• Nylondielectriccircuitbreakersonthe

hydraulic fittings.

Power Voltage Heat. time Δt=50°C

Max. oper. temp.

Max. oper. press.

Net Weight

Hydraulic fittings

kW V~ min °C MPa kg KW-WW

1,2 230 198 75 0,8 15,50 R ½

Power Voltage Heat. time

Δt=50°CInsul.

ThicknessHeat loss

65°CMax. oper. temp.

Max. oper. press.

Net Weight

Hydraulic fittings A B

kW V~ min mm kWh/24h °C MPa kg KW-WW mm mm

1,5 230 123 ≥25 0,87 75 0,8 14,0 R ½ 596 375

1,5 230 196 ≥25 1,13 75 0,8 18,5 R ½ 799 587

1,5 230 245 ≥25 1,30 75 0,8 23,5 R ½ 1013 801

1 3

Capacity

l

SSWVX65 65

Capacity

l

ISWVX 50 50

ISWVX 80 80

ISWVX 100 100

Easy inoxSERIES 65

eXtra inoxSERIES 50-80-100

eLeCTRIC WaTeR HeaTeRS storage type, wall-mounted

Page 14: Style Boiler

Z

DE

F

A

C

B

WW

KW

Stainless steel floor-standing electric storage water heaters are designed to meet the new expectations as to durability and perfection. To this end, the “inox” (stainless steel) product line was introduced, providing maximum qua-lity and durability owing to the use of special materials such as stainless steel and sophisticated technological solutions such as “TIG” and “Plasma” welding. The insulation layer is made of very thick high-density polyurethane (PU) foam to minimise heat loss. They are ideal for collective and industrial use.

• Aisi316Lstainlesssteeltankweldedwith “TIG” and “Plasma” technology.

• Ø134mmfrontinspectionhatch.• Ø134mmflangeonthetopofthe

tank complete with counter flange.• “Correx®”electronicprotection

device with titanium anode and signalling LED.

• Three-partincoloy800stainlesssteel heating element.

• Regulationandsafetycapillarythermostat.

• CFCandHCFC-freeverythickpolyurethane (PU) foam insulation layer.

• Externalcolouredplastic(PVC)coating.

• Adjustablefeetforfloorstanding.• Storedwatertemperatureindicator.

Accessories on page 20

STaINLeSS STeeL heating element

Capacity Power Voltage Heat. time Δt=50°C

Insul. Thickness

Heat loss 65°C

Max. oper. temp.

Max. oper. press.

Net Weight

Hydraulic fittings Recirculation A B C D E F

l kW V~ min mm kWh/24h °C MPa kg KW-WW Z mm mm mm mm mm mm

1,5 230 294 ≥50 1,50 75 1,0 33 Rp ¾ Rp ¾ 610 654 833 213 443 608

2,0 230 294 ≥50 1,70 75 1,0 37 Rp ¾ Rp ¾ 610 654 1018 213 518 793

2,0 230 367 ≥50 2,00 75 1,0 42 Rp ¾ Rp ¾ 610 654 1290 213 618 1065

4,0 400/3 275 ≥50 2,40 75 1,0 69 Rp 1 Rp 1 650 698 1526 228 803 1283

8,0 400/3 184 ≥50 2,80 75 1,0 74 Rp 1 Rp 1 750 798 1530 263 763 1248

10,0 400/3 184 ≥50 3,30 75 1,0 84 Rp 1 Rp 1 750 798 1796 263 913 1513

1 4

Capacity

l

ISSX 120 120

ISSX 160 160

ISSX 200 200

ISSX 300/3 300

ISSX 400/3 400

ISSX 500/3 500

Interline inoxSERIES 120-160-200-300-400-500

eLeCTRIC WaTeR HeaTeRSfloor-standing storage

Page 15: Style Boiler

KW

Z

WW

�A B

C

DE

F

• AISI316Lstainlesssteelboiler,welded with “TIG” and “Plasma” technology.

• DoubleØ134mmfronthatchwayforelectrical Kit assembly and inspection.

• Ø134mmtopbottom-flangecomplete with counter-flange and probe pipe.

• Verythickexpandedpolyurethane(PU) / (EPS) insulation layer. “Easy entry” system.

• Externalcolouredplasticcoating.• Adjustablefeetforfloorstanding.• Storedwatertemperatureindicator.

Accessories on page 20

Floor-standing electric storage water heaters are designed to meet the new expectations of the market as to durability and great storage. To this end, this product line was introduced, providing maximum quality and durability owing to the use of special materials and sophisticated technological solu-tions, such as TIG and plasma welding. The insulation layer is manufactured by means of a new system that combines thetechnologyoftheinjectedpolyurethane(PU)withtheflexibilityofNEO-POR (EPS). This solution allows the installer to have a “plug and play” product and, in case of need, it is an easy solution for making the product pass through openings whose width equals 800 mm. This system allows a trouble-free di-sassembly and re-assembly of the insulation layer for an easier installation in boiler rooms. The two big front hatchways characterise the line of these pro-ducts and make them flexible and suitable for several combinations of electri-cal powers up to maximum 20 KW. The electrical components are supplied apart in handy single- and three-phase KITs with Incoloy 800 stainless steel heating elements with powers up to 10 kW. They are recommended for collec-tive use.

KITResistenza INOX

Capacty Insul. Thickness

Max. oper. temp.

Max. oper. press.

Net Weight

Hydraulic fittings

Recirculation fittings A B C D E F

mm °C MPa kg KW-WW Z mm mm mm mm mm mm

<50 75 1,0 146 Rp 1 ½ Rp 1 ½ 880 925 1865 320 982 1580

<50 75 1,0 170 Rp 1 ½ Rp 1 ½ 880 925 2245 320 1165 1960

1 5

Capacity

ISSX 800 800

ISSX 1000 1000

Interline high storage inoxSERIES 800-1000

eLeCTRIC WaTeR HeaTeRSstorage type, floor-standing

Page 16: Style Boiler

Stainless steel double coil storage indirect cylinders are made using technologies that guarantee maximum quality and durability owing to the use of special materials and sophisticated technological solutions such as “TIG” and “Plasma” welding. They can be connected to central heating systems, forced flow solar-powered systems and can be fitted with further integration systems. Recommended for industrial and collective use.• Aisi316Lstainlesssteeltankwelded

with “TIG” and “Plasma” technology.• Ø134mmfrontinspectionhatch.• Ø134mmtopinspectionflange

complete with counter flange and sensor sheath (Tr).

• Corrosion-proofmagnesiumanode.• Loweredcoiltooptimisetheheat

exchange process and limit the formation of limescale.

• Hydraulicconnectionslocated on the rear.

• Externalcolouredplastic(PVC)coating.

• Recirculationfitting.

• Storedwatertemperatureindicator.• CFCandHCFC-freeverythick

polyurethane (PU) foam insulation layer.

• Adjustablefeetforfloorstanding.• IntegrationKITSavailableforusewith

incoloy 800 stainless steel heating elements of up to 10 kW with single and three-phase connection.

• Versionfittedwith“Correx®”electronicprotection device with titanium anode and signalling LED available upon request.

Accessories on page 20

Series 120-160-200-300-400-5001 Coil

Heat exchange surface

Power (Δt 35)*

D.H.W. production (Δt 35 k)*

Heating time (Δt 35k)*

Flow resistance

Primary flow rate

Insulation thickness

Heat loss 65° C

m² kW l/h min mbar m³/h mm kWh/24h0,60 27,0 663 11 115 2,0 ≥50 1,50

0,80 36,5 896 11 117 2,0 ≥50 1,70

1,00 40,5 995 13 178 2,0 ≥50 2,00

1,40 59,0 1460 13 140 3,0 ≥50 2,40

2,00 81,0 1989 13 183 3,0 ≥50 2,80

2,40 91,0 2229 14 235 3,0 ≥50 3,30

Coil position

Surface échange

Power(Δt 35)*

D.H.W. production (Δt 35 k)*

Heating time (Δt 35k)*

Flow resistance

Primary flow rate

Insulation thickness

Heat loss 65° C

sup/inf m² kW l/h min mbar m³/h mm kWh/24hsup. 0,80 41 1006 19 130

3,0 ≥50 2,40inf. 1,30 59 1460 13 140

sup. 0,80 41 1006 25 1303,0 ≥50 2,80

inf. 1,60 65 1605 16 147sup. 0,80 41 1006 31 130

3,0 ≥50 3,30inf. 2,10 81 1989 16 183

Max. operating temperature

Max. operating pressure

Net Weight

Hydraulicfittings

Exchanger fittings

Recirculation fittings A B C D E F G H L M

°C MPa kg KW-WW PV-PR Z mm mm mm mm mm mm mm mm mm mm95 1,0 93 Rp 1 Rp 1 Rp 1 650 698 1526 228 320 688 843 969 1191 128395 1,0 100 Rp 1 Rp 1 Rp 1 750 798 1530 263 355 695 848 971 1156 124895 1,0 114 Rp 1 Rp 1 Rp 1 750 798 1796 263 355 855 1043 1208 1393 1513

Note: *Primary circuit temperature 80°C / Secondary circuit temperature 10 /45°C / Primary flow rate indicated in the table -D.H.W. = domestic hot water. top = coil at the top;-bot. = coil at the bottom

Series 300-400-5002 Coils

Max. operating temperature

Max. operating pressure

NetWeight

Hydraulicfittings

Exchangerfittings

Recirculation fittings A B C D E F G H

°C MPa kg KW-WW PV-PR Z mm mm mm mm mm mm mm mm95 1,0 38 Rp ¾ Rp ¾ Rp ¾ 610 654 833 213 323 443 533 60895 1,0 43 Rp ¾ Rp ¾ Rp ¾ 610 654 1018 213 323 518 683 79395 1,0 51 Rp ¾ Rp ¾ Rp ¾ 610 654 1290 213 323 618 783 1065 95 1,0 87 Rp 1 Rp 1 Rp 1 650 698 1526 228 338 803 918 128395 1,0 93 Rp 1 Rp 1 Rp 1 750 798 1530 263 373 763 1063 124895 1,0 110 Rp 1 Rp 1 Rp 1 750 798 1796 263 373 913 1153 1513

1 6

Capacity

l

ISSWX 120 120

ISSWX 160 160

ISSWX 200 200

ISSWX 300 300

ISSWX 400 400

ISSWX 500 500

Capacity

l

ISSWWX 300 300

ISSWWX 400 400

ISSWWX 500 500

ISSWWX 300ISSWWX 400ISSWWX 500

ISSWX 120ISSWX 160ISSWX 200ISSWX 300ISSWX 400ISSWX 500

Free Standing

HIGH STORaGestorage indirect heating

Page 17: Style Boiler

ISSWX 500ISSWX 400ISSWX 300ISSWX 200ISSWX 160ISSWX 120

ISSWX 120ISSWX 160ISSWX 200ISSWX 300ISSWX 400ISSWX 500

kW

mba

r

005001051002052003053004054005055006056007

0,50,40,30,20,1

010203040506070809001011

0,50,40,30,20,1

ISSWX 500ISSWX 400ISSWX 300ISSWX 200ISSWX 160ISSWX 120

ISSWX 120ISSWX 160ISSWX 200ISSWX 300ISSWX 400ISSWX 500

kW

mba

r

005001051002052003053004054005055006056007

0,50,40,30,20,1

010203040506070809001011

0,50,40,30,20,1

Z

VP

RP

rT

D

E

F

G

H

A

C

B

WW

KW

KW

Z

WW

PV1

PR1

PR2

PV2

DE

FGH

LM

C

A B

ISSWWX 300-500 sup.

ISSWWX 300 inf.

ISSWWX 400 inf.

ISSWWX 500 inf.

ISSWWX 300-500 sup.

ISSWWX 300 inf.

ISSWWX 400 inf.

ISSWWX 500 inf.

kW

mba

r

015102520353045405550656075708580959001501

0,50,40,30,20,1

Potenza

Portata m

005001051002052003053004054005

0,50,40,30,20,1

Perdite di carico

Portata m

ISSWWX 300-500 sup.

ISSWWX 300 inf.

ISSWWX 400 inf.

ISSWWX 500 inf.

ISSWWX 300-500 sup.

ISSWWX 300 inf.

ISSWWX 400 inf.

ISSWWX 500 inf.

kW

mba

r

015102520353045405550656075708580959001501

0,50,40,30,20,1

Potenza

Portata m

005001051002052003053004054005

0,50,40,30,20,1

Perdite di carico

Portata m

120160200300400500

120160200300400500

Power kW Flow resistance mbar

Flow rate m³ /h Flow rate m³ /h

Power kW Flow resistance mbar

Flow rate m³ /h Flow rate m³ /h

300-500 top.

300 bot.

400 bot.

500 bot.

300-500 top.

300 bot.

400 bot

500 bot.

1 Coil Inox, series: 120-160-200-300-400-500

2 Coil Inox, series: 300-400-500

1 7

INDIReCT CYLINDeRS SINGLe aND DOuBLe COIL

Page 18: Style Boiler

Double fixed coil floor-standing storage indirect cylinders are designed to meet the new expectations of the market as to durability, exchange power and great storage. To this end, this product line was introduced, providing great capacities, maxi-mum quality and durability owing to the use of special materials and sophisti-cated technological solutions, such as TIG and plasma welding.The insulation layer is manufactured by means of a new system that combines thetechnologyoftheinjectedpolyurethane(PU)withtheflexibilityofNEO-POR (EPS).This solution allows the installer to have a “plug and play” product and, in case of need, it is an easy solution for making the product pass through openings whose width equals 800 mm. This system allows a trouble-free disassembly and re-assembly of the insulation layer for an easier installation in boiler ro-oms.The two big front hatchways characterise the line of these products and make them flexible and suitable for several combinations of electrical integrations. They are recommended for collective use.

• AISI316Lstainlesssteelboiler,welded with “TIG” and “Plasma” technology.

• DoubleØ134mmfronthatchwayforelectrical Kit assembly and inspection.

• Ø134mmtopbottom-flangecomplete with counter-flange and probe pipe.

• Exchangerswithloweredturnstostreamline the heat exchange and reduce the formation of limescale.

• Verythickexpandedpolyurethane(PU) / (EPS) insulation layer. “Easy entry” system.

• Externalcolouredplasticcoating.• Adjustablefeetforfloorstanding.• Storedwatertemperatureindicator.• Theyareavailableinelectrical

integration kits with the use of Incoloy 800 stainless steel heating elements up to 10 kW with single- and three-phase connections.

Accessories on page 20

Average insul. layer thickness

Heat exchange

surface Power

(Δt 35 K)* D.H.W.

production (Δt 35 K)*

Heating time (Δt 35 K)*

Primary flow rate

Max. operating

temp.

Max. operating pressure

Net Weight

Hydraulic fittings

Exchanger fittings

Recirculation fittings

mm m² kW l/h min m³/h °C MPa kg KW-WW PV-PR Z

>100 3,05 110 2703 18 3,0 95 1,0 195 Rp 1¼ Rp 1¼ Rp 1¼

>100 3,55 130 3194 19 3,0 95 1,0 226 Rp 1¼ Rp 1¼ Rp 1¼

* Note: Primary temperature 80°C / Secondary input temperature 10/45°C / Primary capacity specified in the table - D.H.W. = Production of domestic hot water.

Average insul. layer thickness

Heat exchange

surface Power

(Δt 35 K)* D.H.W.

production (Δt 35 K)*

Heating time (Δt 35 K)*

Primary flow rate

Max. operating

temp.

Max. operating pressure

Net Weight

Hydraulic fittings

Exchanger fittings

Exchanger fittings

Recirculation fittings

mm sup/inf m² kW l/h min m³/h °C MPa kg KW-WW PV-PR Z

>100sup. 1,30 59 1460 13

3,0 95 1,0 206 Rp 1¼ Rp 1¼ Rp 1¼inf. 3,05 110 2703 18

>100sup. 1,30 59 1460 13

3,0 95 1,0 237 Rp 1¼ Rp 1¼ Rp 1¼inf. 3,55 130 3194 19

* Note: Primary temperature 80°C / Secondary input temperature 10/45°C / Primary capacity specified in the table - D.H.W. = Production of domestic hot water

Series 800-10001 Coil

Series 800-10002 Coils

1 8

Capacity

l

ISSWX 800 800

ISSWX 1000 1000

Capacity

l

ISSWWX 800

800

ISSWWX 1000

1000

Free Standinghigh storage inox

INDIReCT CYLINDeRS SINGLe aND DOuBLe COILstorage indirect heating

Page 19: Style Boiler

KW

Z

WW

PV

PR

A B

C

DE

F

G

H

KW

Z

WW

PV1

PR1

PR2

PV2

�A B

DEFG

HLM

C

A B C D E F G H

mm mm mm mm mm mm mm mm

880 925 1865 320 425 982 1187 1580

880 925 2245 320 425 1165 1303 1960

“easy entry” system

A B C D E F G H L M

mm mm mm mm mm mm mm mm mm mm

880 925 1865 320 425 985 1090 1178 1475 1580

880 925 2245 320 425 1187 1340 1578 1855 1960

1 9

ISSWX 800

ISSWX 1000

ISSWWX 800

ISSWWX 1000

INDIReCT CYLINDeRS SINGLe aND DOuBLe COIL

Page 20: Style Boiler

accessories & kit for Inox stainless steel productsCODe DeSCRIpTION

071078 1”1/4 2,0 KW 230 V- SINGLE-PHASE ELECTRICAL KIT formed by: 1”1/4 sleeve, gasket, AISI 321 stainless steel armoured heating element and thermostat to be installed on the lateral screwed connection

071079 1”1/4 3,0 KW 230 V- SINGLE-PHASE ELECTRICAL KIT formed by: 1”1/4 sleeve, gasket, AISI 321 stainless steel armoured heating element and thermostat to be installed on the lateral screwed connection

070137 3.0÷6.0 kW 400/3V˜ THREE-PHASE INOX ELECTRICAL KITRECOMMENDED FOR SERIES 160-200-300formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket.

070138 4.0÷8.0 kW 400/3 V˜ THREE-PHASE INOX ELECTRICAL KIT RECOMMENDED FOR SERIES 400-500-600-800-1000formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket.

070136 5.0÷10.0 kW 400/3 V˜ THREE-PHASE INOX ELECTRICAL KIT RECOMMENDED FOR SERIES 400-500-600-800-1000formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket.

2 0

INOX KITS aND aCCeSSORIeS

Page 21: Style Boiler

The “STReNGTHS” of the product range in detail:

2 1

This range of indirect cylinders performs indirect heating via one or two fi-xed coils or by means of an air casing with extensive heat exchange surfaces. They provide an easy and abundant supply of hot water for all uses.They can be connected to both independent and central heating systems, or to remote heating systems or they can be used in forced flow solar-powered systems, providing high heat exchange efficiency levels. The range of capa-cities covered by this product line is from 115 to 1000 litres with power ratings of between 20 kW and over 100 kW of heat output.The models available include “undermount” appliances to be fitted below the boiler, which are ideally combined with any wall-hung boiler for the pro-duction of large quantities of hot water in a limited amount of space, along with the multi-purpose “free standing” versions which comprise single and double coil indirect cylinders, designed to integrate several types of energy available, from methane gas via a gas boiler, to electrical installations using the integration kit available, and even solar energy systems with the forced flow solar-powered systems.The line of indirect cylinders is completed with the “multi-position” air casing version which has a distinguishing trait: its versatility, which makes both ver-tical and horizontal as well as floor-standing installations possible.

Thermal insulationInsulation layer made of very thick high-den-sity polyurethane (PU) foam that guarantees excellent insulation.

Tank protection against wearThanks to the “flow-coating” enamelling pro-cess at 850°C for guaranteed quality internal protection.

Magnesium anodeFeatured in all the models in the range, this anode makes for effective electrochemical tank protection.

Environmentally friendlyStyleboiler strives to optimise its industrial activity while respecting the environment. To minimise the environmental impact of its products, it has abolished the use of chloro-fluorocarbons (CFC-HCFC) in the insulation layer and makes continuous efforts to use recyclable components.

Indirect cylinders

Page 22: Style Boiler

WW

Z

PV PR

E

KW

152

A

110

082

570

159

45°

173,5

159

Potenza kW

45

101,0 2,0 2,5 3,0 4,0

15

20

25

30

35

40

BSC 115

BSC 150

Portata m³/h

kW

Perdite di carico mbar

900

01,0 2,0 2,5 3,0 4,0

150

300

450

600

750

BSC 115

BSC 150

Portata m³/h

mba

r

Potenza kW

45

101,0 2,0 2,5 3,0 4,0

15

20

25

30

35

40

BSC 115

BSC 150

Portata m³/h

kW

Perdite di carico mbar

900

01,0 2,0 2,5 3,0 4,0

150

300

450

600

750

BSC 115

BSC 150

Portata m³/h

mba

r

Power kW Flow resistance mbar

Flow rate m³ /h Flow rate m³ /h

Verticalstoragesinglecoilindirectcylindersaredesignedtobecombinedwithany wall-hung boiler for the production of large quantities of hot water despite space restrictions. They are recommended for domestic use.

• Steeltank,glass-linedusingtheflow-coating method (850 °C).

• Ø134mmtopinspectionflangecomplete with counter flange and sensor sheath (Tr).

• Corrosion-proofmagnesiumanode.• Loweredcoiltooptimisetheheat

exchange process and limit the formation of limescale.

• Recirculationandoutletfittings.• Externalcasingmadeofsheetmetal

coated with epoxy powder paint.

• Hydraulicfittingsatthetoptofacilitate connections with the wall-hung boiler.

• CFCandHCFC-freeverythickpolyurethane (PU) foam insulation layer.

• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.

• Feetforfloorstanding.• Storedwatertemperatureindicator.

Accessories on page 31/32

View from above

115

150 115

150

Capacity Heat exchange surface

Power (∆T 35 k)*

D.H.W. production (∆T 35 k)*

Heating time (ΔT 35k)*

Flow resistance

Primary flow rate

Insulation thickness

Heat loss 65 °C

l m² kW l/h min mbar m³/h mm kWh/24h0,90 27 663 11 189 2,0 ≥35 1,301,00 30 732 13 219 2,0 ≥35 1,90

Max. operating temperature

Max. operating pressure

NetWeight

Hydraulicfittings

Exchangerfittings

Recirculation fittings

Outletfitting A

°C MPa kg KW-WW PV-PR Z E mm95 1,0 53 R ¾ R ¾ R ¾ Rp ½ 86295 1,0 61 R ¾ R ¾ R ¾ Rp ½ 1064

Note: *Primary circuit temperature 80°C / Secondary circuit temperature 10 /45°C / Primary flow rate indicated in the table -D.H.W. = domestic hot water.

2 2

Capacity

ISSWG 115 115ISSWG 150 150

ISSWG 115ISSWG 150

UndermountSERIES 115-150

INDIReCT CYLINDeRS SINGLe COILvertical, storage indirect heating

Page 23: Style Boiler

PV WW

120

200

149

100

270

576

PRKWZ

561

A

PV WW

120

200

149

100

270

576

PRKWZ

561

A

10

15

20

25

30

35

40

0,35,20,25,10,1

kW

Portata m3/h

Potenza kW

0

450

300

150

0,35,20,25,10,1

Portata m3/h

mba

r

Perdite di carico mbar

ISSWT 120

ISSWT 160

ISSWT 120

ISSWT 160

10

15

20

25

30

35

40

0,35,20,25,10,1

kW

Portata m3/h

Potenza kW

0

450

300

150

0,35,20,25,10,1

Portata m3/h

mba

r

Perdite di carico mbar

ISSWT 120

ISSWT 160

ISSWT 120

ISSWT 160

Power kW Flow resistance mbar

Flow rate m³ /h Flow rate m³ /h

• Steeltank,glass-linedusing the “powder” method (850°C).

• ø 134 mm top inspec-tion flange complete with counter-flange and probe sheath (Tr).

• Corrosion-proofmagne-sium anode.

• Streamlinedcoilforthemaximum heat exchange

process and to reduce the formation of limescale.

• Outletandrecirculationfittings.

• Hydraulicfittingsinstalledin the upper part to facilitate the connection with a wall-hung boiler.

• Self-extinguishingandverythick high-density (EPS) polystyrene-shell insulation

layer.• Anti-collisionexternal

colouredPVCcoating.• Adjustablefeetforfloor

standing.• Storedwatertemperature

indicator.• Draincock.

Accessories on page 31/32

120

160

120

160

Capacity Heat exchange surface

Power (∆T 35 k)*

D.H.W. production(∆T 35 k)*

Heating time (ΔT 35k)*

Flow resistance

Primary flow rate

Insulation thickness

l m² kW l/h min mbar m³/h mm1,15 32 780 10 170 2,0 >301,20 32 780 13 172 2,0 >30

Max. operating temperature

Max. operating pressure

Netweight

Hydraulic fittings

Exchanger fittings

Recirculation fittings

Outlet fitting A

°C MPa kg KW-WW PV-PR Z E mm95 1,0 54 R ¾ R ¾ R ¾ Rp ½ 845

95 1,0 64 R ¾ R ¾ R ¾ Rp ½ 1045

* Note: Primary temperature 80°C / Secondary inlet temperature 10/45°C Primary capacity specified in the table - D.H.W. = Production of domestic hot.

Vertical single coil storage indirect cylinders aredesigned tobe combinedwith anywall-hung boiler for the production of large quantities of hot water despite space re-strictions. The rectangular shape can be suitably fitted as an undermount indirect cylin-der.ThecolouredPVCcoatingenhancesitslinesandprotectsitagainstpossiblecolli-sions during assembly operations and normal use. In addition, the product has been designed so that it can be completely disassembled at the end of its life cycle, in a way to allow its correct recycling and/or the disposal of its components. It is recommended for domestic use.

2 3

Capacity

ISSWT 120 120ISSWT 160 160

ISSWT 120ISSWT 160

UndermountSERIES 120-160

INDIRECT CYLINDERS SINGLE COILstorage type, indirect heating

Page 24: Style Boiler

Big OneSERIES 300-400-500

Indirect cylinders with increased size single fixed coil. They are designed for an easy and abundant supply of sanitary hot water by means of heat pumps. They can be connected with central heating systems and equipped with addi-tional integration systems. They are recommended for collective use.

• Steeltank,glass-linedusingtheflow-coating method (850 °C).

• Ø134mmfrontinspectionhatch.• 2Corrosion-proofmagnesiumanode.• Highefficiencyloweredcoildesigned

to optimise the thermal exchange and to reduce limestone.

• Sensorsheath(Tr)locatedontheupper part.

• Hydraulicconnectionslocated on the rear.

• Externalcolouredplastic(PVC)coating.

• Adjustablefeetforfloorstanding.

• CFCandHCFC-freethickpolyurethane(PU) foam insulation layer.

• Storedwatertemperatureindicator.• IntegrationKITSavailableforusewith

tinned copper spiral heat exchangers or copper heating elements up to 5 kW and incoloy 800 stainless steel heating elements up to 10 kW with single and three-phase connection.

Accessories on page 31/32

Hydraulic connections

Exchanger connections

Recirculation connections Vent N. of

probes A B C D E F G H L M

KW-WW PV-PR Z S Tr mm mm mm mm mm mm mm mm mm mm

Rp 1" Rp 1" Rp 1" G 3/4" 1 650 675 1560 148 338 828 1258 1408 1586 170

Rp 1" Rp 1" Rp 1" G 3/4" 1 750 775 1553 162 388 778 1228 1386 1576 190

Rp 1" Rp 1" Rp 1" G 3/4" 1 750 775 1818 162 391 931 1471 1651 1841 190

Heat exchange surface

(average) insulation layer

thickness Heat loss

65°C Maximum operating

temperature

Maximum operating pressure

Net weight

Primary flow rate

Power (Δt 35k)*

DHW production (Δt 35k)*

Pressure loss

m² mm kWh/24h °C MPa kg m³/h kW l/h mbar

3,8 ≥50 2,4 95 1,0 113 2 84 1950 425

4,5 ≥50 2,8 95 1,0 147 2 87,5 2050 461

5,5 ≥50 3,3 95 1,0 178 2 88,7 2090 563

*Primary circuit temperature 80°C / Secondary circuit temperature 10 /45°C / Primary flow rate indicated in the table / DHW= domestic hot water

newnew

2 4

ISSWH 300

ISSWH 400

ISSWH 500

Capacity

l

ISSWH 300 300

ISSWH 400 400

ISSWH 500 500

storage indirect heating INDIRECT CYLINDERS INCREASED SIzE SINGLE COIL

Page 25: Style Boiler

0

100

200

300

400

500

600

700

800

0,0 0,5 1,0 1,5 2,0 2,5 3,0

kWmbar

0

10

20

30

40

50

60

70

80

90

100

0,0 0,5 1,0 1,5 2,0 2,50

100

200

300

400

500

600

700

800

0,0 0,5 1,0 1,5 2,0 2,5 3,0

kWmbar

0

10

20

30

40

50

60

70

80

90

100

0,0 0,5 1,0 1,5 2,0 2,5

Power kW Flow resistance mbar

Flow rate m³ /h Flow rate m³ /h

300

400

500

300

400

500

2 5

INDIRECT CYLINDERS INCREASED SIzE SINGLE COIL

Page 26: Style Boiler

Single and double coil storage indirect cylinders use indirect heating. They provi-de an easy and abundant supply of hot water for all uses. They can be connected to central heating systems, forced flow solar-powered systems and can be fitted with further integration systems. Recommended for industrial and collective use.

• Steeltank,glass-linedusingthe flow-coating method (850 °C).

• Ø 134 mm front inspection hatch.

• Corrosion-proofmagnesiumanode.

• Doublecoil,optimisedformaximum heat exchange and minimum limescale build-up.

• Threesensorsheaths(Tr)

located on the rear.• Hydraulicconnections

located on the rear.• Recirculationfitting.• CFCandHCFC-freeverythick

polyurethane (PU) foam insulation layer.

• Externalcolouredplastic(PVC)coating.

• Adjustablefeetforfloorstanding.

• Storedwatertemperatureindicator.

• IntegrationKITSavailableforuse with tinned copper spiral heat exchangers or copper heating elements of up to 5 kW and incoloy 800 stainless steel heating elements of up to 10 kW with single and three-phase connection.

Accessories on page 31/32

Series 120-160-200-300-400-500-600

Heat exchange surface

Power (∆T 35 k)*

D.H.W. production(∆T 35 k)*

Heating time (ΔT 35k)*

Flow resistance Primary flow rate Insulation

thicknessHeat loss

65 °CMax. operating

temperature

m² kW l/h min mbar m³/h mm kWh/24h °C0,60 20 491 15 119 2,0 ≥50 1,50 950,85 27 663 15 182 2,0 ≥50 1,70 951,00 30 737 17 223 2,0 ≥50 2,00 951,40 44 1081 18 138 3,0 ≥50 2,40 951,70 55 1351 19 180 3,0 ≥50 2,80 952,10 63 1543 20 223 3,0 ≥50 3,30 952,90 70 1720 31 75 3,0 ≥50 3,60 95

1 Coil

Max. operating pressure

Net weight

Hydraulic fittings

Exchanger fittings

Recirculation fittings

No. of sensors A B C D E F G H L M

MPa kg KW-WW PV-PR Z Tr mm mm mm mm mm mm mm mm mm mm1,0 45 Rp ¾ Rp ¾ Rp ¾ 2 610 620 854 150 311 414 486 571 631 7201,0 57 Rp ¾ Rp ¾ Rp ¾ 2 610 620 1056 150 311 416 551 701 781 9221,0 66 Rp ¾ Rp ¾ Rp ¾ 2 610 620 1329 150 311 486 651 801 881 11951,0 97 Rp 1 Rp 1 Rp 1 2 650 675 1560 148 338 538 828 978 1058 14081,0 123 Rp 1 Rp 1 Rp 1 2 750 775 1553 162 392 560 782 932 1012 13871,0 144 Rp 1 Rp 1 Rp 1 2 750 775 1818 162 392 554 932 1082 1162 16521,0 220 Rp 1 Rp 1¼ Rp 1 2 810 832 1819 124 331 456 871 1161 1241 1659

Note: *primary circuit temperature 80°C / secondary circuit temperature 10 /45°C / primary flow rate indicated in the table -D.H.W. = domestic hot water.

Coil position

Heat exchange surface

Power (∆T 35 k)*

D.H.W. production (∆T 35 k)*

Heating time (ΔT 35k)*

Flow resistance

Primary flow rate

Insulation thickness

Heat loss65 °C

Max. operating temp.

sup/inf m² kW l/h min mbar m³/h mm kWh/24h °Csup. 0,50 22 541 23 119

2,0 ≥50 2,00 95inf. 0,70 25,5 627 21 182

sup. 0,90 31,5 774 24 1003,0 ≥50 2,40 95

inf. 1,40 44 1081 18 138sup. 0,90 31,5 774 33 100

3,0 ≥50 2,80 95inf. 1,70 55 1351 19 180

sup. 0,90 31,5 774 41 1003,0 ≥50 3,30 95

inf. 2,10 63 1543 20 223sup. 1,00 34 835 45 64

3,0 ≥ 50 3,60 95inf. 2,50 68 1671 23 73

Series 200-300-400-500-6002 Coils

Max. operating pressure

Net weight

Hydraulic fittings

Exchanger fittings

Recirculation fittings

No. of Sensors A B C D E F G H L M N O P

MPa kg KW-WW PV-PR Z Tr mm mm mm mm mm mm mm mm mm mm mm mm mm1,0 61 Rp ¾ Rp ¾ Rp ¾ 3 610 620 1329 150 261 336 581 661 747 841 1041 1108 11951,0 105 Rp 1 Rp 1 Rp 1 3 650 675 1560 148 288 378 693 773 859 956 1225 1292 14081,0 133 Rp 1 Rp 1 Rp 1 3 750 775 1553 162 322 402 722 800 879 977 1177 1259 13871,0 154 Rp 1 Rp 1 Rp 1 3 750 775 1818 162 322 437 872 972 1072 1172 1372 1457 16521,0 234 Rp 1 Rp 1 ¼ Rp 1 3 808 833 1749 123 330 435 945 1035 1110 1200 1452 1527 1658

Note: *primary circuit temperature 80°C / secondary circuit temperature 10 /45°C / primary flow rate indicated in the table -D.H.W. = domestic hot water -top = coil at the top;-bot. = coil at the bottom

2 6

Capacity

lISSW 120 120ISSW 160 160ISSW 200 200ISSW 300 300ISSW 400 400ISSW 500 500ISSW 600 600

ISSW 120ISSW 160ISSW 200ISSW 300ISSW 400ISSW 500ISSW 600

Capacity

l

ISSWW 200 200

ISSWW 300 300

ISSWW 400 400

ISSWW 500 500

ISSWW 600 600

ISSWW 200ISSWW 300ISSWW 400ISSWW 500ISSWW 600

Free Standing

vertical, storage indirect heating INDIReCT CYLINDeRS SINGLe aND DOuBLe COIL

Page 27: Style Boiler

KW

Z

WW

PV1

PR1

PR2

PV2

DE

G

LMN

P

C

A B

F

H

O

Tr

Tr

Tr

Potenza kW

85807570656055504540353025201510

1,0 2,0 3,0 5,04,0

BSS 120BSS 160BSS 200BSS 300BSS 400BSS 500BSS 600

Portata m³/h

kW

Perdite di carico mbar800750700650600550500450400350300250200150100

500

1,0 2,0 3,0 5,04,0

BSS 120BSS 160BSS 200BSS 300BSS 400BSS 500BSS 600

Portata m³/h

mbar

Potenza kW

85807570656055504540353025201510

1,0 2,0 3,0 5,04,0

BSS 120BSS 160BSS 200BSS 300BSS 400BSS 500BSS 600

Portata m³/h

kWPerdite di carico mbar

800750700650600550500450400350300250200150100

500

1,0 2,0 3,0 5,04,0

BSS 120BSS 160BSS 200BSS 300BSS 400BSS 500BSS 600

Portata m³/h

mbar

01510252035304540555065607

8057

0,40,30,20,1

kW

Potenza

Portata m

005001051002052003053004054005055006056007

0,40,30,20,1

mba

r

Perdite di carico

Portata m

ISSWW 600 inf.

ISSWW 500 inf.

ISSWW 400 inf.

ISSWW 300 inf.

ISSWW 200 inf.

ISSWW 600 sup.

ISSWW 300-500 sup.ISSWW 200 sup.

ISSWW 200 sup.

ISSWW 600 sup.

ISSWW 300-500 sup.ISSWW 200 inf.ISSWW 300 inf.ISSWW 400 inf.ISSWW 500 inf.ISSWW 600 inf.

01510252035304540555065607

8057

0,40,30,20,1

kW

Potenza

Portata m

005001051002052003053004054005055006056007

0,40,30,20,1

mba

r

Perdite di carico

Portata m

ISSWW 600 inf.

ISSWW 500 inf.

ISSWW 400 inf.

ISSWW 300 inf.

ISSWW 200 inf.

ISSWW 600 sup.

ISSWW 300-500 sup.ISSWW 200 sup.

ISSWW 200 sup.

ISSWW 600 sup.

ISSWW 300-500 sup.ISSWW 200 inf.ISSWW 300 inf.ISSWW 400 inf.ISSWW 500 inf.ISSWW 600 inf.

Power kW Flow resistance mbar

Flow rate m³ /hFlow rate m³ /h

120160200300400500600

120160200300400500600

Power kW Flow resistance mbar

Flow rate m³ /h Flow rate m³ /h

600bot.500 bot.400 bot.300 bot.200 bot.600top300-500 top200 top

200 top300-500 top200 bot.300 bot.400 bot.500 bot.600bot.600top

1 Coil, series 120-160-200-300-400-500-600

2 Coil, series 200-300-400-500-600

2 7

INDIReCT CYLINDeRS SINGLe aND DOuBLe COIL

Page 28: Style Boiler

Single and double fixed coil floor-standing storage indirect cylinders are desi-gned to meet the new expectations of the market as to durability, exchange power and great storage.To this end, this new high-capacity product line was introduced, providing maximum quality and durability owing to the use of special materials and so-phisticated technological solutions.The guarantee of durability in time is further extended by means of a modern “glass-lining” treatment over the tank.The insulation layer is manufactured by means of a new system that combines thetechnologyoftheinjectedpolyurethane(PU)withtheflexibilityofNEO-POR (EPS). This solution allows the installer to have a “plug and play” product and, in case of need, it is an easy solution for making the product pass through openings whose width equals 800 mm. This system allows a trouble-free disassembly and re-assembly of the insula-tion layer for an easier installation in boiler rooms. The two big front hatchways characterise the line of these products and make them flexible and suitable for several combinations of electrical powers up to maximum 20 kW. The electrical components are supplied apart in handy sin-gle- and three-phase KITs with Incoloy 800 stainless steel heating elements with powers up to 10 kW or made of copper up to 5 kW. Furthermore, you can equip the tank with spiroid exchangers, if any, which can be installed in the hatchways. They are recommended for collective use.

• Glass-linedsteelboiler.• DoubleØ134mmfronthatchwayfor

electrical Kit assembly and inspection.• Ø134mmtopbottom-flangecomplete

with counter-flange.• Streamlineddoublecoilforthemaximum

heat exchange process and to reduce the formation of limescale.

• Verythickexpandedpolyurethane(PU)/(EPS) insulation layer. “Easy entry” system.

• Externalcolouredplasticcoating.• Adjustablefeetforfloorstanding.• Storedwatertemperatureindicator.• Theyareavailableinelectricalintegration

kits with the use of Incoloy 800 stainless

steel heating elements up to 10 kW with single- and three-phase connections.

Accessories on page 31/32

Average insul. layer thickness

Heat exchange

surface Power

(∆T 35 k)*D.H.W.

production(∆T 35 k)*

Heating time

(ΔT 35k)*

Primary flow rate

Max. operating

temp.

Max. operating pressure

Net weight

Hydraulic fittings

Exchanger fittings

Recirculation fittings

mm m² kW l/h min m³/h °C MPa kg KW-WW PV-PR Z

>100 3,00 88 2162 24 3,0 95 1,0 272 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼

>100 3,50 100 2457 26 3,0 95 1,0 299 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼

* Note: Primary temperature 80°C / Secondary temperature:10/45°C - D.H.W. = production of domestic hot water.

Series 800-1000

1 Coil

Average insul. layer thickness

Coil fittings

Heat exchange

surface Power

(∆T 35 k)*D.H.W.

production(∆T 35 k)*

Heating time

(ΔT 35k)*

Primary flow rate

Max. operating

temp.

Max. operating pressure

Net weight

Hydraulic fittings

Exchanger fittings

Recirculation fittings

mm top/bot. m² kW l/h min m³/h °C MPa kg KW-WW PV-PR Z

>100top 1,20 40 983 52

3,0 95 1,0 292 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼172227 3,00 88 2162 24

>100top 1,50 48 1179 54

3,0 95 1,0 323 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼bot. 3,50 100 2457 26

* Note: Primary temperature 80°C / Secondary temperature 10/45°C / D.H.W. = production of domestic hot water

2 CoilSeries 800-1000

2 8

Capacity

l

ISSW 800 800

ISSW 1000 1000

Capacity

l

ISSWW 800 800

ISSWW 1000 1000

Free Standinghigh storage

storage indirect heating INDIReCT CYLINDeR SINGLe aND DOuBLe COIL

Page 29: Style Boiler

KW

Z

WW

PV

PR

C

A B

DEFG

H

KW

Z

WW

PV1

PR1

PR2

PV2

C

A B

DE

FGHLM

“easy entry” system

A B C D E F G H

mm mm mm mm mm mm mm mm

880 925 1865 191 371 1071 971 1676

880 925 2245 191 371 1231 1121 2056

A B C D E F G H L M

mm mm mm mm mm mm mm mm mm mm

880 925 1865 191 371 1071 971 1251 1461 1676

880 925 2245 191 371 1231 1121 1431 1831 2056

2 9

ISSW 800

ISSW 1000

ISSWW 800

ISSWW 1000

INDIReCT CYLINDeR SINGLe aND DOuBLe COIL

Page 30: Style Boiler

Potenza kW

50

45

40

35

30

25

20

15

50,5 1 1,5 2,52

0,5 1 1,5 2,52

BMI 80

BMI 100

BMI 115 - 150

BMI 200

BMI 300

Portata m³/h

kW

Produzione A.C.S l/h

700800900

100011001200

600500400300200100

Portata m³/h

l/h

BMI 80

BMI 100

BMI 115 - 150

BMI 200

BMI 300

Potenza kW

50

45

40

35

30

25

20

15

50,5 1 1,5 2,52

0,5 1 1,5 2,52

BMI 80

BMI 100

BMI 115 - 150

BMI 200

BMI 300

Portata m³/h

kW

Produzione A.C.S l/h

700800900

100011001200

600500400300200100

Portata m³/h

l/h

BMI 80

BMI 100

BMI 115 - 150

BMI 200

BMI 300

Power kW D.H.W. production l/h

80100115-150200300

80100115-150200300

MultipositionSERIES 80-100-115-150-200-300

Multi-position storage air casing indirect cylinders are a convenient and cheap so-lution to your domestic hot water requirements. Their strength lies in the exhausti-ve nature of the range, from 80 to 300 litres, and in the versatility of installation; moreover, thanks to the limited flow resistance, they are ideal for use in natural flow systems. Recommended for domestic and collective use.• Steeltank,glass-linedusingthe

flow-coating method (850 °C).• �88mminspectionflangecomplete

with counter flange and sensor sheath.• Corrosion-proofmagnesiumanode.• Heatexchangerwithaircasing,

optimised for natural flow systems owing to the reduced flow resistance.

• CFCandHCFC-freepolyurethane(PU)foam insulation layer.

• Recirculationfitting.

• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.

• Primarycircuitfittingsonbothsidesformaximum installation flexibility.

• Multi-positioninstallationoptions:vertical or horizontal, wall-mounted or floor-standing (floor-standing installa-tion only for mod. 300).

• ElectricintegrationKITSavailable(exceptfor the 300 litre model).

Accessories on page 31/32

Versions80-100-115-150-200

Version300

Max. operating pressure

Max. operating pressure

of air casingNet

WeightHydraulic

fittingsExchanger

fittingsRecirculation

fittings A B C D E F G H L

MPa MPa kg KW-WW PV-PR Z mm mm mm mm mm mm mm mm mm0,8 0,4 42 R ¾ Rp 1 ¼ R ¾ 470 844 223 463 295 65 65 257 3200,8 0,4 51 R ¾ Rp 1 ¼ R ¾ 470 1057 223 856 295 65 65 257 5000,8 0,4 59,5 R ¾ Rp 1 ¼ R ¾ 470 1228 223 1027 295 65 65 257 6700,8 0,4 67 R ¾ Rp 1 ¼ R ¾ 570 1025 214 819 450 115 115 262 5000,8 0,4 83,5 R ¾ Rp 1 ¼ R ¾ 570 1295 214 1086 450 115 115 262 8000,8 0,4 130 R 1 Rp 1 ¼ R 1 see diagram

Note: *primary circuit temperature 80°C / secondary circuit temp 10 /45°C / primary flow rate indicated in the table -D.H.W. = domestic hot water. Floor-standing installation only for model GMI 300.

Capacity Heat exchange surface

Power (∆T 35 k)*

D.H.W. production (∆T 35 k)*

Heating time (ΔT 35k)*

Primary flow rate

Max. operating temperature

m² kW l/h min m³/h °C0,65 14 350 15 2,0 950,90 22 540 12 2,0 951,10 26 645 11 2,0 951,10 26 645 15 2,0 951,50 33 815 16 2,0 952,00 45 1115 17 2,0 95

Flow rate m³ /h Flow rate m³ /h

3 0

GmI 80GmI 100GmI 115GmI 150GmI 200GmI 300

Capacity

lGmI 80 80GmI 100 100GmI 115 115GmI 150 150GmI 200 200GmI 300 300

storage indirect heating INDIReCT CYLINDeRS SINGLe COIL

Page 31: Style Boiler

accessories & kit for indirect cylinder

CODe DeSCRIpTION

070281 PRIORITY KIT formed by: thermostat in exchange, two-contact relay, bipolar switch, wired cap.

071037 1”1/4 2,0 KW 230 V- SINGLE-PHASE ELECTRICAL KIT formed by: 1”1/4 sleeve, gasket, armoured heating element and thermostat to be installed on the lateral screwed connection

071038 1”1/4 3,0 KW 230 V- SINGLE-PHASE ELECTRICAL KIT composto da: manicotto 1 ¼, guarnizione, resistenza blindata in rame e termostato per installazione su predisposizione attacco filettato laterale

071078 1”1/4 2,0 KW 230 V- SINGLE-PHASE ELECTRICAL KIT formed by: 1”1/4 sleeve, gasket, AISI 321 stainless steel armoured heating element and thermostat to be installed on the lateral screwed connection

071079 1”1/4 3,0 KW 230 V- SINGLE-PHASE ELECTRICAL KIT formed by: 1”1/4 sleeve, gasket, AISI 321 stainless steel armoured heating element and thermostat to be installed on the lateral screwed connection

070265 2.0 kW 230 V~ 1” SINGLE-PHASE ELECTRICAL KITformed by: counter-flange with 1” sleeve, gasket, copper armoured heating element and thermostat.

070266 3.0 kW 230 V~ 1” SINGLE-PHASE ELECTRICAL KIT formed by: counter-flange with 1” sleeve, gasket, copper armoured heating element and thermostat.

070267 3.0 kW 400/3 V~ 2” THREE-PHASE ELECTRICAL KIT cormed by: counter-flange with 2” sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectors.N.B. not suitable for 800 L and 1000 L model

070268 4.0 kW 400/3 V~ 2” THREE-PHASE ELECTRICAL KITformed by: counter-flange with 2” sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectors.N.B. not suitable for 800 L and 1000 L model

070269 5.0 kW 400/3 V~ 2” THREE-PHASE ELECTRICAL KIT formed by: counter-flange with 2” sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectors.N.B. not suitable for 800 L and 1000 L model

3 1

UNDERMOUNT

FREE STANDING

FREE STANDING

FREE STANDING

FREE STANDING

INDIReCT CYLINDeR

Page 32: Style Boiler

accessories & kit for indirect cylinder

CODe DeSCRIpTION

030528 SPIROID EXCHANGER KIT 1.0 sqm formed by: counter-flange, finned coil made of tinned copper 1 sqm; gasket, union set, round grill, fastening screws and nuts. FOR ALL SERIES

030525 SPIROID EXCHANGER KIT 1.8 sqm ONLY FOR SERIES 400-500-600-800-1000 formed by: counter-flange, finned coil made of tinned copper 1.8 sqm; gasket, union set, round grill, fastening screws and nuts..

070137 3.0÷6.0 kW 400/3V~ THREE-PHASE INOX ELECTRICAL KIT formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. RECOMMENDED FOR SERIES 160-200-300

070138 4.0÷8.0 kW 400/3 V~ THREE-PHASE INOX ELECTRICAL KIT formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. RECOMMENDED FOR SERIES 400-500-600-800-1000

070136 5.0÷8.0 kW 400/3 V~ THREE-PHASE INOX ELECTRICAL KITformed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. RECOMMENDED FOR SERIES 400-500-600-800-1000

070133 1.2 kW 230 V~ ELECTRICAL KIT - FOR SERIES 80-100 formed by: copper armoured heating element, thermostat and wired cap. Only for wall-mount vertical or horizontal installations.

070134 1.5 kW 230 V~ ELECTRICAL KIT - FOR SERIES 115 formed by: copper armoured heating element, thermostat and wired cap.Only for wall-mount vertical or horizontal installations

070127 2.0 kW 230 V~ ELECTRICAL KIT - FOR SERIES 150-200

090629 Feet for floor standing. FOR SERIES 80-100-115-150-200

3 2

FREE STANDING

FREE STANDING

MULTIPOSITION

INDIReCT CYLINDeR

Page 33: Style Boiler

Thermal insulation layerIt is manufactured with very thick and high-density polyurethane foam to assure excel-lent thermal insulation.• Rigidpolyurethane(PU)for200÷600lmodels.• Flexiblepolyurethane(PU)for800÷1.000lt. models.

Recycling800 and 1,000l puffers have been designed so that they can be completely disassembled at the end of their life cycle, in a way to allow their correct recycling and/or the disposal of their components.

Respect of the environmentWe undertakes streamlining the industrial activities and the respect of the environment. In order to reduce the impact over the envi-ronment to the minimum, we removed the hydrofluorocarbons (CFC-HCFC) from the insulation layer, and always pays great atten-tion to the recyclability of the components.

The “STReNGTHS” of the product range in detail:

The range of inertial puffers is formed by heating water storages with the opportunity to combine a fixed coil exchanger, too. They allow storing heating water generated by discontinuous heating sy-stems; therefore, they allow a considerable recovery and/or exploitation of thermal energy that would be unused or even wasted. From this point of view, they well integrate into energy saving systems, and become the “thermal source” of the energy system within heating and dome-stic hot water generation systems.Owing to their peculiarity, they are usually connected to systems that ge-nerate heat in a discontinuous way, such as for example wood-fired boilers, solid-fuel stacks or stoves, or rather installed in low water systems to limit the interventions of the burners.As for the version with fixed exchanger, besides what is said above, it is used for maximum exploitation of “thermal solar systems” or with “heat pump”. The capacity field covered by this range is included between 200 and 1,000 litres.Product lines cover the standard, with front hatchway, solar with fixed exchanger and front hatchway up to solar with the production of domestic hot water. All products are equipped with fittings for electric integrations by means of specific kits from 3.0 kW to 12.0 kW, while the products having the hatchway can install further electric kits from 2.0 to 10.0 kW, or kits with tinned copper spiroid exchangers.

3 3

Inertial puffers

Page 34: Style Boiler

Inertial puffers are characterised by the ability to store heating water that co-mes from several sources, mainly discontinuous ones.In addition, they are arranged for the installation of an electric integration, which is supplied by means of specific kits up to 12 kW.

• Rawcarbonsteelinternaltank.

• Hydraulicfittingstobefound on the rear.

• Probesheaths(Tr)tobefound on the rear.

• CFCandHCFC-freeverythick rigid expanded polyurethane (PU)

insulation layer. “Easy entry” system plus (EPS) for series 800/1000.

• Externalcolouredplastic(PVC)coating.

• Adjustablefeetforfloorstanding.

• Arrangementofelectricheating element with

front 1” sleeve.• AvailableelectricalKIT

with Incoloy 825 stainless steel heating elements on a 1” fitting with powers from 3 to 12 kW and three-phase connection.

Series 200-300-400-500-600-700-800-1000Insulation layer

thicknessMax. working temperature

Max. working pressure

Net weight

Heating element fitting

Hydraulicfittings

Fitting on upper bottom

Number of probes/diameter Nr/mm

mm °C MPa kg R M, RI, RC, SC, Ric Nr/mm>50 PU 95 0,3 51 Rp 1 ½ Rp ¾ Rp 2 3/Ø16>50 PU 95 0,3 75 Rp 1 ½ Rp 1 Rp 2 3/Ø16>50 PU 95 0,3 97 Rp 1 ½ Rp 1 Rp 2 3/Ø16>50 PU 95 0,3 113 Rp 1 ½ Rp 1 Rp 2 3/Ø16>50 PU 95 0,3 174 Rp 1 ½ Rp 1 Rp 2 3/Ø16

>50 95 0,3 140 Rp 1 ½ Rp 1 ¼ Rp 2 3/Rp1/2>50 95 0,3 164 Rp 1 ½ Rp 1 ¼ Rp 2 3/Rp1/2

Series 200-300-400-500-600-700-800-1000

Capacity Insulation layer thickness

Max. working temperature

Max. working pressure

Net weight

Heating element fitting

Hydraulicfittings

Fitting on upper bottom

Number of probes/diameter Nr/mm

l mm °C MPa kg R M, RI, RC, SC, Ric Nr/mm>50 PU 95 0,3 53 Rp 1 ½ Rp ¾ Rp 2 3/Ø16>50 PU 95 0,3 77 Rp 1 ½ Rp 1 Rp 2 3/Ø16>50 PU 95 0,3 99 Rp 1 ½ Rp 1 Rp 2 3/Ø16>50 PU 95 0,3 115 Rp 1 ½ Rp 1 Rp 2 3/Ø16>50 PU 95 0,3 176 Rp 1 ½ Rp 1 Rp 2 3/Ø16

>50 95 0,3 143 Rp 1 ½ Rp 1 ¼ Rp 2 3/Rp1/2>50 95 0,3 167 Rp 1 ½ Rp 1 ¼ Rp 2 3/Rp1/2

Series 800-1000Exchange

surfacePower

(Δt 35)*D.H.W. production

(Δt 35 k)*Heating time

(Δt 35k)Primary capacity

Insulation layer thickness

Maximum working temperature

m² kW l/h min m³/h mm °C3,00 88 2162 24 3,0 >50 953,50 100 2457 26 3,0 >50 95

Maximum workingpressure

Net weight

Exchanger fittings

Heating element fitting

Hydraulic fittings

Fitting on upper bottom

Number of probes/diameter

MPa kg PV-PR R M, RI, RC, SC, Ric Nr/mm0,3 205 Rp 1 ¼ Rp 1 ½ Rp 1 ¼ Rp 2 3/Rp1/20,3 241 Rp 1 ¼ Rp 1 ½ Rp 1 ¼ Rp 2 3/Rp1/2

3 TO 9 KW 1 1/2 INCOLOY 825 STAINLESS STEEL THREE-PHASE HEATING ELEMENT ELECTRICAL KIT

071000 3kW400/3V-1”1/2electricalkit

071001 6kW400/3V-1”1/2electricalkit

071002 9kW400/3V-1”1/2electricalkit

3 4

Capacity

lISpHO 200 200ISpHO 300 300ISpHO 400 400ISpHO 500 500ISpHO 600 600ISpHO 800 800ISpHO 1000 1000

Capacity

ISpH 200 200ISpH 300 300ISpH 400 400ISpH 500 500ISpH 600 600ISpH 800 800ISpH 1000 1000

Capacity

ISpHW 750 750ISpHW 950 950

ISpHW 750ISpHW 950

PH

PH no HatCHway

PH witH HatCHway

PH witH HatCHway and one Coil

puFFeR Intertial Puffer

Page 35: Style Boiler

CS /2 IR

CR

I .ciR1 IR

2 IM

CM

1 IM

rT

rT

rT

DE

FG

HL

M

R

N

RI 2 / SC

RC

Ric. I

RI 1

MI 2

MC

MI 1

A

C

N

R

0

DE

FG

HL

M

N

C

RI 2 / SC

RC

Tr

Tr

Tr

Ric.1

Rl1

Ml 2

Ml 1

MC

R

B

ML

HG F

ED

OA

RI 2 / SC

RC

Ric. IRI 1

MI 2

MC

MI 1

A

C

N

R

0

DE

FG

HL

M

B�

RI 2 / SC

RC

Ric. IRI 1MI 2

MC

MI 1

SCA 1

SCAU

C

A

DE

FG

HL

M

NO

P

R

A C D E F G H L M N

mm mm mm mm mm mm mm mm mm mm610 1329 150 261 621 761 841 1041 1195 735650 1560 156 336 751 841 984 1236 1416 785755 1553 161 321 721 878 976 1176 1385 839755 1818 161 364 914 1056 1131 1381 1651 906810 1749 123 330 930 1075 1150 1400 1658 891880 1865 191 371 971 1071 1251 1461 1676 1123880 2245 191 371 1121 1231 1431 1831 2056 1268

with hatchway 200÷600

with hatchway and one coil

NO hatchway

with hatchway 800÷1000

A B C D E F G H L M N

mm mm mm mm mm mm mm mm mm mm mm610 627 1329 150 261 621 761 841 1041 1195 735650 674 1560 156 336 751 841 984 1236 1416 785755 775 1553 161 321 721 878 976 1176 1385 839755 775 1818 161 364 914 1056 1131 1381 1651 906810 827 1749 123 330 930 1075 1150 1400 1658 891880 910 1865 191 371 971 1071 1251 1461 1676 1123880 910 2245 191 371 1121 1231 1431 1831 2056 1268

A B C D E F G H L M N O

mm mm mm mm mm mm mm mm mm mm mm mm880 910 1865 191 371 971 1071 1251 1461 1676 371 971880 910 2245 191 371 1121 1231 1431 1831 2056 371 1121

3 5

ISpHO 200ISpHO 300ISpHO 400ISpHO 500ISpHO 600ISpHO 800ISpHO 1000

ISpH 200ISpH 300ISpH 400ISpH 500ISpH 600ISpH 800ISpH 1000

ISpH W 750ISpH W 950

puFFeR

Page 36: Style Boiler

The “Tank in Tank” range of solar puffers with the production of domestic hot water is an integrated system formed by a thermal storage for heating (puffer) and a glass-lined tank, which is dipped inside the puffer, for the production of domestic hot water.The insulation layer is manufactured by means of a new system that combines thetechnologyoftheinjectedpolyurethane(PU)withtheflexibilityofNEO-POR (EPS) (only for series 750-900). This solution allows the installer to have a “plug and play” product and, in case of need, it is an easy solution for making the product pass through openings whose width equals 800 mm. This system allows a trouble-free disassembly and re-assembly of the insula-tion layer for an easier installation in boiler rooms. Owing to their peculiarity, they are usually connected to systems that genera-te heat in a discontinuous way, such as for example wood-fired boilers, solid-fuel stacks or stoves, or rather installed in low water systems to limit the inter-ventions of the burners.The fixed exchanger to be found in the system is used for maximum exploita-tion of “thermal solar systems” or with “heat pump”.

• Rawcarbonsteelinternaltank(puffer).• Carbonsteelfixedexchangerwelded

to the puffer.• Perforateddiaphragmfastenedtothe

puffer for improved internal lamina-tion.

• Domestichotwatersteeltank,glass-lined using the flow-coating method (850°C).

• Corrosion-proofmagnesiumanode(domestic hot water tank).

• Hydraulicfittingstobefound on the rear.

• Probesheaths(Tr)tobefound on the rear.

• CFCandHCFC-freeverythickexpanded polyurethane insulation layer.

• “Easyentry”systemforseries750 and 900.

• Externalcolouredplastic(PVC)coating.

• Adjustablefeetforfloorstanding.

D.H.W. capacity

Exchange surface

Power (Δt 35)*

Insulation layer thickness

Maximum working temperature

Heating working maximum pressure

l m² kW mm °C MPa

130 2,10 81 ≥ 50 95 0,3

180 2,50 91 ≥ 50 95 0,3

230 3,00 105 ≥ 50 95 0,3

DHW working maximum pressure

Net weight

Exchanger fittings

Vent fitting

DHW fittings

Heating fitting

Number of probes/diameter

MPa kg PV-PR SF WW, Z, KW HZ VL, HZ RL Nr/mm

0,8 190 Rp 1 ¼ Rp ¾ Rp ¾ Rp 1 4/ Rp ½

0,8 220 Rp 1 ¼ Rp ¾ Rp ¾ Rp 1 ¼ 4/ Rp ½

0,8 260 Rp 1 ¼ Rp ¾ Rp ¾ Rp 1 ¼ 4/ Rp ½

3 6

Heating capacity

l

TTS 600/130 470

TTS 750/180 570

TTS 900/230 670

TTS 600/130

TTS 750/180

TTS 900/230

TTSSERIES 600-750-900

SOLaR puFFeRTank in Tank

Page 37: Style Boiler

WW KW

C/SPR

PV

Tr

Tr

Tr

Tr

DEFGH

ILP

�A

NO

M

SF

Z

C

B

att� att�

att� att�

att� att�

att� att�

att�

A C D E F G H L M N O

mm mm mm mm mm mm mm mm mm mm mm

810 780 1831 130 270 395 870 1603 200 180 245

880 800 1932 196 351 445 951 1623 200 180 245

880 800 2305 196 376 481 1026 1996 200 180 245

3 7

TTS 600/130

TTS 750/180

TTS 900/230

SOLaR puFFeR

Page 38: Style Boiler
Page 39: Style Boiler

The range of gas water heaters is the result of detailed research and in-depth experiments related to the efficiency, safety, aesthetic appearance and ener-gy savings in strict compliance with the applicable norms in force. The range of capacities covered by this product line is from 50 to 2000 litres with power ratings of between 4 kW and over 34 kW of heat output. The ran-ge meets both the domestic requirements of a typical home as well as those of industrial and collective settings. The product lines include “natural draught” appliances, which are ideal for the rapid and cheap production both small and large quantities of water, as well as the sophisticated “fan flue” appliances which also solve installation difficulties when traditional systems cannot be fitted.

Thermal insulationInsulation layer made of very thick (range for collective use) high-density polyurethane (PU) foam that guarantees excellent insula-tion.

Tank protection against wearThanks to the “flow-coating” enamelling pro-cess at 850°C for guaranteed quality internal protection or via classic hot galvanising process(forseries600-2000only).

Magnesium anodeFeatured in all the models in the range, this anode makes for effective electrochemical tank protection.

Multi-gas burnerAll the gas powered appliance models are fit-ted with multi-gas burners for operation with methane gas or LPG.

Maximum safetyTriple safety gas valve with operating ther-mostat, flame detection thermocouple (ioni-sation for electronic versions) and maximum temperature thermostat and flue gas sensor (for natural draught versions) to avoid possi-ble malfunctions.

Environmentally friendlyWe strive to optimise its industrial activity while respecting the environment. To mini-mise the environmental impact of its pro-ducts, it has abolished the use of chlorofluo-rocarbons (CFC-HCFC) in the insulation layer and makes continuous efforts to use recycla-ble components.

The “STReNGTHS” of the product range in detail:

3 9

Gas water heaters

Page 40: Style Boiler

G

A

450

475

F

112

100

348

B

22WW KW

Natural draughtSERIES 50-80-100-120

Wall-hungstorageopen-ventedand“Naturaldraught”gaswaterheatersarethe simplest and cheapest solution for the rapid production of domestic hot water.

• Steeltank,glass-linedusingthe“flow-coating” method (850°C).

• Corrosion-proofmagnesiumanode.• CFCandHCFC-freepolyurethane(PU)

foam insulation layer.• Externalcasingmadeofsheetmetal

coated with epoxy powder paint.• Piezoelectricignition.• Burnerwith3distributingpipes.• Triplesafetygasvalve:operating

thermostat, flame detection thermo-couple and maximum temperature control.

• Fluegassensor(DCF).• Storedwatertemperatureindicator.• Designedtooperateonmethanegas

or LPG (nozzles included).• Operationwithoutelectricalconnec-

tions.

Capacity Heat Output

Useful Power

Heat. time Δt=50°C

Cont. flow rate

Δt=30°C

Max. qty. of flue gases

Flue gas temp.

Methane consumption

LPG consumption

Max. operating

temp.

Max. operating

press.Net

WeightHydraulic

fittingsGas

fittingØFlue gas discharge A B

l kW kW min l/min g/s °C m³/h g/h °C MPa kg KW-WW G F (mm) mm mm

4,5 3,8 43 1,8 1,96 308 0,50 300 75 0,8 20 R ½ G 3/8 81 654 261

6,2 5,3 55 2,5 2,75 292 0,65 395 75 0,8 28 R ½ G 3/8 81 939 546

6,2 5,3 65 2,5 3,22 284 0,65 395 75 0,8 32 R ½ G 3/8 81 1024 631

6,5 5,6 77 2,7 3,31 275 0,70 425 75 0,8 36 R ½ G 3/8 81 1174 781

Note: open-vented, natural draught B11BS / category II 2H3+

View from above

Ø

4 0

Capacity

eGN 50 45

eGN 80 80

eGN 100 94

eGN 120 118

GaS WaTeR HeaTeRwall-hung, storage open-vented

Page 41: Style Boiler

G

072

286

C

AB

204

160

160

470

212

D

F

WW KW

Fan flueSERIES 80-120

Wall-hung storage room-sealed and “Fan flue” gas water heaters are a sophisti-cated yet brilliant way to solve the most challenging installation difficulties where traditional appliances cannot be used, for the rapid production of do-mestic hot water.

• Steeltank,glass-linedusingthe“flow-coating” method (850°C).

• Corrosion-proofmagnesiumanode.• CFCandHCFC-freepolyurethane(PU)

foam insulation layer.• Externalcasingmadeofsheetmetal

coated with epoxy powder paint.• Electronicignitionwithflame

detection and ionisation flame control.

• Fluegasextractionfanwithsafetypressure switch.

• Triplesafetygasvalve:operatingthermostat, ionisation flame detection and maximum temperature control.

• Storedwatertemperatureindicator.• Designedtooperateonmethanegas

or LPG (nozzles included).• Coaxialorsplitfluegasdischarge

available.

Accessories on page 46

View from above

Capacity Heat Output

Useful Power

Heat. time Δt=50°C

Cont. flow rate Δt=30°C

Max. qty. of flue gases

Flue gas

temp.Methane

consumptionLPG

consumptionMax.

operating temp.

Max. operating

press.Net

weightHydraulic

fittingsGas

fittingØ Flue

gas discharge

A B C D

l kW kW min l/min g/s °C m³/h g/h °C MPa kg KW-WW G F (mm) mm mm mm mm

4,0 3,4 84 1,6 2,20 91 0,42 246 75 0,8 40 R ½ R 3/8 28 1069 940 360 632

4,0 3,4 127 1,6 2,20 91 0,42 246 75 0,8 48 R ½ R 3/8 28 1300 1171 591 867

Note: room-sealed, fan flue C12 C32 C42 C82 / category II 2H3+ / Max absorbed power: 44W -230V~

4 1

Capacity

TF 80 78

TF 120 118

GaS WaTeR HeaTeRwall-hung, storage room-sealed

Page 42: Style Boiler

118

25970

Z

E

G

669

1417

1479

Z

EG

374

C

AB

F470

230 230

65

WW KW WW KW

570F

Ø

Natural draughtSERIES 115-150-200

Floor-standingstorageopen-ventedand“Naturaldraught”gaswaterheatersare the best solution for the production of large quantities of domestic hot water. They are also ideal for collective use (on campsites, in sports facilities and hotels, for example) and in industrial settings.

• Steeltank,glass-linedusingthe“flow-coating” method (850°C).

• Corrosion-proofmagnesiumanode.• CFCandHCFC-freepolyurethane(PU)

foam insulation layer.• Externalcasingmadeofsheetmetal

coated with epoxy powder paint.• Piezoelectricignition.• Storedwatertemperatureindicator.

• Triplesafetygasvalve:operatingthermostat, flame detection thermo-couple and maximum temperature control.

• Fluegassensor(DCF).• Designedtooperateonmethanegas

or LPG (nozzles included).• Operationwithoutelectricalconnec-

tions.

115/150 200

Capacity Heat output

Useful power

Heat. time

∆t=50°C

Cont. flow rate ∆t=30°C

Max. qty. of flue gases

Flue gas

temp.

Methane consum-

ption

LPG consum-

ption

Max. operating

temp.

Max. operating

press.Net

weightHydraulic

fittingsRecirculation

and discharge

Gas fitting

ØFlue gas

dischargeA B C

l kW kW min l/min g/s °C m³/h g/h °C MPa kg KW-WW Z-E G F (mm) mm mm mm

6,9 5,7 72 2,7 3,36 284 0,75 445 75 0,8 41 R ¾ Rp ¾ R ½ 81 1212 1274 674

7,2 6,0 92 2,8 3,80 242 0,76 445 75 0,8 50 R ¾ Rp ¾ R ½ 81 1511 1573 824

8,0 6,6 111 3,2 3,76 234 0,84 495 75 0,8 71 R ¾ Rp ¾ R ½ 81 Vedi schema

Note: open-vented, natural draught B11BS / category II 2H3+

View from above

View from above

4 2

Capacity

l

eG/p 115 112

eG/p 150 150

eG/p 200 200

GaS WaTeR HeaTeRwall-hung, storage open-vented

Page 43: Style Boiler

G

E

Z

499

A

133

F

499B

C

720

E

499

499B

C

A

Z

WW

KW

WW

KW

F 720

G

Natural draughtSERIES 300-500

Floor-standingstorageopen-ventedand“Naturaldraught”gaswaterheatersare designed to store large quantities of hot water with a view to ensuring greater value for money. The version featuring electronic ignition combines economic use with maximum flame control precision. These water heaters are ideal for collective use (on campsites, in sports facilities and hotels, for exam-ple) and in industrial settings.

• Steeltank,glass-linedusingtheflow-coating method (850°C).

• ø 134 mm front inspection hatch.• Corrosion-proofmagnesiumanode.• CFCandHCFC-freeverythick

polyurethane (PU) foam insulation layer.

• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.

• Fluegassensor(DCF).

• Piezoelectricignition(electronicforthe EG/PRE version).

• Triplesafetygasvalve:operatingthermostat, flame detection thermo-couple (ionisation for the EG/PRE version) and maximum temperature control.

• Storedwatertemperatureindicator.• Designedtooperateonmethanegas

or LPG (nozzles included).

300/500 300/500electronic version

Capacity Heat output

Useful Power

Heat. time

∆t=50°C

Cont. flow rate

∆t=30°C

Max. qty.

of flue gases

Flue gas

temp.

Methane consum-

ption

LPG consum-

ption

Max. operating

temp.

Max. operating

press.Net

weightHydraulic

fittingsRecirculation

and discharge

Gas fitting

ØFlue gas

dischargeA B C

l kW kW min l/min g/s °C m³/h g/h °C MPa kg KW-WW Z-E G F (mm) mm mm mm

19,5 17,2 62 8,2 9,59 230 2,10 1250 75 0,8 133 Rp 1 Rp ¾ R ¾ 122 1611 821 1084

19,5 17,2 62 8,2 9,59 230 2,10 1250 75 0,8 133 Rp 1 Rp ¾ R ¾ 122 1611 821 1084

24,0 21,0 82 10,0 11,58 214 2,52 1500 75 0,8 178 Rp 1 Rp ¾ R ¾ 122 2144 1285 1643

24,0 21,0 82 10,0 11,58 214 2,52 1500 75 0,8 178 Rp 1 Rp ¾ R ¾ 122 2144 1285 1643

Note: for the EG/PRE electronic version, the appliance needs to be connected to the 230 V~ electricity mains / open-vented, natural draught B11BS / category II 2H3+

4 3

Capacity

eG/pR 300 290

eG/pRe 300* 290

eG/pR 500 470

eG/pRe 500* 470

GaS WaTeR HeaTeRwall-hung, storage open-vented

Page 44: Style Boiler

Z

A F

GE

D

B

C

WW

KW

Natural draughtSERIES 600-800-1000-1500-2000

Floor-standingstorageopen-ventedand“Naturaldraught”highcapacitygaswater heaters provide large quantities of hot water and can be installed in series/parallel where large consumption levels are required. The version featu-ring electronic ignition combines economic use with maximum flame control precision. These water heaters are ideal for collective use (on campsites, in sports facilities and hotels, for example) and in industrial settings.

• Hotgalvanisedsteeltank.• Corrosion-proofmagnesiumanode.• Verythickmineralwoolinsulation

layer for reduced heat loss.• Storedwatertemperatureindicator.• Externalcasingmadeofpre-painted

sheet metal.• Piezoelectricignition.• Triplesafetygasvalve:operating

thermostat, flame detection thermo-couple and maximum temperature control.

• Fluegassensor(DCF).• Designedtooperateonmethanegas

or LPG (nozzles included).• Operationwithoutelectricalconnec-

tions.• Electronicversion(EG/PE)available

upon request.

A B C D E G

mm mm mm mm mm mm

780 2165 2000 1730 1010 310

980 1975 1810 1470 900 340

1080 2025 1860 1470 900 340

1180 2255 2090 2000 960 340

1280 2475 2310 2150 960 340

Capacity Heat Output

Useful Power

Heat. time

∆t=50°C

Cont. flow rate ∆t=30°C

Max. qty. of flue gases

Fluegas

temp.

Methane consum-

ption

LPG consum-

ption

Max. operating

temp.

Max. operating

press.Net

WeightHydraulic

fittingsRecirculation

and discharge

Gas fitting

Ø Flue gas

discharge

l kW kW min l/min g/s °C m³/h g/h °C MPa kg KW-WW Z-E G F (mm)

26,7 22,9 92 10,9 23,2 136 2,70 1988 75 0,6 194 Rp 1 Rp 1 R ½ 140

34,8 29,9 98 14,3 31,1 135 3,60 2581 75 0,6 241 Rp 1 ¼ Rp 1 ¼ R ½ 160

34,8 30,2 115 14,3 31,1 135 3,60 2581 75 0,6 276 Rp 1 ¼ Rp 1 ¼ R ½ 160

34,8 29,6 180 14,1 31,1 135 3,60 2581 75 0,6 377 Rp 1 ¼ Rp 1 ¼ R ½ 160

34,8 30,2 225 14,3 31,1 135 3,60 2581 75 0,6 452 Rp 1 ¼ Rp 1 ¼ R ½ 160

Note: open-vented, natural draught B11BS / category II 2H3+

*Version with electronic ignition

4 4

eG/p 600

eG/p 800

eG/p 1000

eG/p 1500

eG/p 2000

Capacity

eG/p 600575

eG/pe 600*eG/p 800

800eG/pe 800*eG/p 1000

950eG/pe 1000*eG/p 1500

1450eG/pe 1500*eG/p 2000

1850eG/pe 2000*

GaS WaTeR HeaTeRwall-hung, storage open-vented

Page 45: Style Boiler

Z

E

C

A

DE

G

B

F

WW

KW

Floor-standing storage room-sealed and “fan flue” gas water heaters feature the most advanced technological solutions to solve the most challenging in-stallation problems. Their electronic controls makes them ideal for collective use (on campsites, in sports facilities and hotels, for example) and in industrial settings.

Fan flueSERIES 220-300-400

• Steeltank,glass-linedusingtheflow-coating method (850°C).

• Corrosion-proofmagnesiumanodewith anode control device.

• Verythickmineralwoolinsulationlayer.

• Externalcasingmadeofpre-paintedsheet metal.

• Electronicignitionwithflamedetection and ionisation flame control.

• Fluegasextractionfanwithsafetypressure switch.

• Triplesafetygasvalve:operatingthermostat, ionisation flame detection and maximum temperature control.

• Timerclock.• Storedwatertemperatureindicator.• Designedtooperateonmethanegas

or LPG (nozzles included).• Coaxialorsplitfluegasdischarge

available.

Accessories on page 46

Capacity Heat output

Useful Power

Heat. time ∆t=50°C

Cont. flow rate ∆t=30°C

Max. qty. of flue gases

Flue gas

temp.

Methane consum-

ption

LPG consum-

ption

Max. operating

temp.

Max. operating

press.Net

weightHydraulic

fittingsRecirculation

and discharge

Gas fitting

Ø Flue gas

discharge

l kW kW min l/min g/s °C m³/h g/h °C MPa kg KW-WW Z-E G F (mm)

26,7 24,1 33 11,5 16,8 172 2,82 2100 75 0,6 141 Rp 1 Rp 1 R ½ 100

30,6 27,1 29 14,6 16,7 162 3,25 2400 75 0,6 170 Rp 1 Rp 1 R ½ 100

30,6 27,1 29 14,6 17,3 157 3,25 2400 75 0,6 210 Rp 1 Rp 1 R ½ 100

Note: room-sealed, fan flue C12 C32 C42 C82 / category II 2H3+ / max absorbed power: 62W -230V~

A B C D E G

mm mm mm mm mm mm

640 1750 390 590 790 1150

640 1975 390 590 790 1375

690 2150 390 590 790 1540

4 5

Capacity

TF 220 220

TF 300 300

TF 400 390

TF 220

TF 300

TF 400

GaS WaTeR HeaTeRwall-hung, storage room-sealed

Page 46: Style Boiler

accessories & kit for gas water hearterCODE DESCRIPTION

FLUE SYSTEMS FOR GAS WATER HEATERSFAN FLUE TF 80-120

030341 COAXIALOUTLETKITØ60/28mm- 1 meter coaxial mouth - 1m 0 60/28 mm coaxial pipe discharge/suction end - wall cover roses

030342 Ø60/28mmcoaxialextensioncord– 0.5 meters

030343 60/28 mm coaxial extension cord – 1.0 meter

140214 90°Ø60/28mmcoaxialelbow

140324 Ø32/28mmSPLITOUTLETKIT- 1 meter n. 1 1 meter Ø 28 mm outlet extension cord n. 1 1 meter Ø 32 mm outlet extension cord discharge/suction end - wall cover roses

030344 Ø28mmoutletextensioncord – 0,5 meters

030363 Ø28mmoutletextensioncord – 1.0 meter

030364 Ø32mmsuctionextensioncord– 0.5 meters

030365 Ø32mmsuctionextensioncord – 1.0 meter

140210 90°Ø28mmoutletelbow

140211 45°Ø28mmoutletelbow

140212 90°Ø32mmsuctionelbow

FLUE SYSTEMS FOR GAS WATERHEATERSFAN FLUETF 220-300-400

140406 COAXIALOUTLETKITØ60/100mm-1 meter multi-directional 90° coaxial elbow with inspections, coaxial pipe and discharge/suction

140414 VerticalØ60/100mmflangedcoaxialstubpipe

140407 Ø60/100mmcoaxialextensioncord- 1.0 meter

140410 90°Ø60/100mmcoaxialelbow

140423 COAXIALOUTLETKITONROOFØ80/110mm- 1 meter coaxial pipe, flanged concentric 118-100 reduction, gasket, 80-60 reduction; device for roof outlet equipped with sleeve and fastening screws

140408 Ø80/-80mmSPLITOUTLETKIT- 1 meter formed by: splitter with condensation outlet and inspections, n.2 90° elbows, n.2 extension cords, suction/discharge

140409 v 80 mm extension cord - 1 meter

140411 90°Ø80mmelbow

4 6

GaS WaTeR HeaTeR

Page 47: Style Boiler

The “STReNGTHS” of the product range in detail:

4 7

The Styleboiler range of electric storage water heaters offers an extensive array of models for the production of domestic hot water (D.H.W.) with a ca-pacity ranging from 10 to 1000 litres and power ratings from 1.2 to 10 kW with single- and three-phase connections. The range meets both the domestic requirements of a typical home as well as those of industrial and collective settings. The product lines include “rapid” models, which are ideal for the rapid and cheap production of small quantities of water, “smart” models which are small water heaters designed for installations where limited space is avai-lable, the classic “standard” models devised to accommodate the essential basic requirements of the market, and also the “interline” product line, pro-viding a large number of combinations to meet the highest expectations as regards quality in observance of European and international standards.

Thermal insulationInsulation layer made of very thick (Interline range) high-density polyurethane (PU) foam that guarantees excellent insulation.

Tank protection against wearThanks to the “flow-coating” enamelling pro-cess at 850°C for guaranteed quality internal protection or via classic Teflon-coating.

Magnesium anodeFeatured in all the models in the range, this anode makes for effective electrochemical tank protection.

External Control Knob (SE)External control knob used to facilitate the waterheater temperatureadjustment,com-bined with the flange for easy inspection and cleaning.

Dual SafetyThanks to the presence of both an operating thermostat and a maximum temperature thermostat to avoid possible malfunctions.

IP Degree of ProtectionStyleboiler water heaters are safe because they are splash-proof and are specially desig-ned for installation close to the water delivery points, even in public and collective settings.

Environmentally friendlyWe strives to optimise its industrial activity while respecting the environment. To mini-mise the environmental impact of its pro-ducts, it has abolished the use of chlorofluo-rocarbons (CFC-HCFC) in the insulation (PU) layer and makes continuous efforts to use recyclable components.

electric Water Heaters

Page 48: Style Boiler

4 8

Capacity Power Voltage Heat. time Δt=50°C

Max. operating temp.

Max. operating press.

NetWeight

Hydraulic fittings A B C D E F G

l kW V~ min °C Mpa Kg KW-WW mm mm mm mm mm mm mm

pony 10/Se 10 1,2 230 30 75 0,8 6,0 R ½ 261 251 450 228 100 62 189

pony 10/Se s 10 1,2 230 30 75 0,8 6,0 R ½ 261 251 450 250 100 62 189

pony 15/Se 15 1,2 230 46 75 0,8 7,5 R ½ 296 285 498 248 100 69 216

pony 15/Se s 15 1,2 230 46 75 0,8 7,5 R ½ 296 285 498 270 100 69 216

pony 30/Se 30 1,2 230 92 75 0,8 10,0 R ½ 366 355 568 384 100 89 266

Note: s = undersink version

Capacity Power Voltage Heat. time Δt=50°C

Max. operating temp.

Max. operating press.

Net Weight

Hydraulic fittings A B C D E F G

l kW V~ min °C Mpa Kg KW-WW mm mm mm mm mm mm mm

pony 10 10 1,2 230 30 75 0,8 6,0 R ½ 261 251 450 228 100 62 189

pony 10 s 10 1,2 230 30 75 0,8 6,0 R ½ 261 251 450 250 100 62 189

pony 15 15 1,2 230 46 75 0,8 7,5 R ½ 296 285 498 248 100 69 216

pony 15 s 15 1,2 230 46 75 0,8 7,5 R ½ 296 285 498 270 100 69 216

pony 30 30 1,2 230 92 75 0,8 10 R ½ 366 355 568 384 100 89 266

Note: s = undersink version.

WWWK

E

C

AD

B

FG

W WK W

E

AC

D

B

FG

WWWK

E

C

A

D

B

FG

W WK W

E

A

C

D

B

FG

oversink version 10-15-30

undersink version10-15

WWWK

E

A

C

D

B

FG

WWWKE

C

A

D

B

FG

WWWK

E

A

C

D

B

FG

WWWKE

C

A

D

B

FG

oversink version 10-15-30 undersink version 10-15

Wall-hung electric storage water heaters are ideal for the rapid and cheap production of small quantities of water. They can be installed above or below the sink (30 Litres above only). The external control knob (SE) makesforeasieradjustmentofthewatertemperature.

Wall-hung electric storage water heaters are ideal for the rapid and cheap produc-tion of small quantities of water. They can be installed above or below the sink (30 Litres above only).

• Steeltank,glass-linedusingtheflow-coatingmethod (850°C).

• Tankinspectionflange.• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelementfitted

on a flange.• Regulationandsafetyrodthermostatwith

external control knob.• Polystyreneinsulatingshells(EPS)forreduced

heat loss.• Shock-resistantpolypropylene(PP)casing

and back.• Bracketsforwallmountingavailableupon

request.• LEDindicatorlight.• IPX5protectivecoveroverelectricalparts.

• Steeltank,glass-linedusingtheflow-coatingmethod (850°C).

• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelementfittedon

a 1 1⁄4 coupling.• Regulationandsafetyrodthermostat.• Polystyreneinsulatingshells(EPS)forreduced

heat loss.• Shock-resistantpolypropylene(PP)casing

and back.• Bracketsforwallmountingavailableuponrequest.• LEDindicator light.• IPX5protectivecoveroverelectricalparts.

Rapid SESERIES 10-15-30

RapidSERIES 10-15-30

external Control Knob

eLeCTRIC WaTeR HeaTeRSwall-hung, storage, installation above or below the sink

Page 49: Style Boiler

KW WW

450277

106,5

021

120

489

260

WKWW

100

368

072

358

115381

554

Wall-hung electric storage water hea-ters are ideal for the rapid and cheap production of small quantities of water where the installation space is limited.

Wall-hung electric storage water hea-ters are ideal for the rapid and cheap production of small quantities of water where the installation space is limited.

• Steeltanktreatedwiththermo-hardeningresins (Teflon) or glass-lined using the flow-coating method (850°C) depending on the model and/or version.

• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelementfitted

on a 1 1⁄4 coupling.• Regulationandsafetyrodthermostat.• CFCandHCFC-freepolyurethane(PU)

foam insulation layer.• Externalcasingmadeofsheetmetal

coated with epoxy powder paint.• LEDindicatorlight.• IPX3protectivecoveroverelectricalparts(IPX2forVB30).

• Storedwatertemperatureindicator.

• Steeltanktreatedwiththermo-hardeningresins (Teflon) or glass-lined using the flow-coating method (850°C) depending on the model and/or version.

• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelementfitted

on a 1 1⁄4 coupling.• Regulationandsafetyrodthermostat.• CFCandHCFC-freepolyurethane(PU)

foam insulation layer.• Externalcasingmadeofsheetmetal

coated with epoxy powder paint.• LEDindicatorlight.• IPX3protectivecoveroverelectricalparts(IPX2forVB30).

• Storedwatertemperatureindicator.

Power Voltage Heat. time Δt=50°C

Max. operating temp.

Max. operating press.

Net weight

Hydraulic fittings

l kW V~ min °C MPa kg KW-WW

1,2 230 77 75 0,8 12 R ½

Power Voltage Heat. time Δt=50°C

Max. operating temp.

Max. operating press.

Net weight

Hydraulic fittings

l kW V~ min °C MPa kg KW-WW

1,2 230 77 75 0,8 12 R ½

Power Voltage Heat. time Δt=50°C

Max. operating temp.

Max. operating press.

Net weight

Hydraulic fittings

l kW V~ min °C MPa kg KW-WW

1,2 230 92 75 0,8 12 R ½

Power Voltage Heat. time Δt=50°C

Max. operating temp.

Max. operating press.

Net weight

Hydraulic fittings

l kW V~ min °C MPa kg KW-WW

1,2 230 92 75 0,8 12 R ½

View from above

4 9

Capacity

VD 30 30

Capacity

VF 30 30

Capacity

VDO 30 25

Capacity

VFO 30 25

Standard miniSERIES 30

SmartSERIES 30

eLeCTRIC WaTeR HeaTeRSwall-hung, storage

Page 50: Style Boiler

WWKW

450

A

100

B

072

211

475

Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The water heaters are avai-lable in a vertical version, vertical universal left-right thermo version, horizon-tal version and horizontal thermo version.

• Steeltanktreatedwiththermo-hard-ening resins (Teflon) or glass-lined using the flow-coating method (850°C) depending on the model and/or version.

• Armouredcopperheatingelementfitted on a 1 1⁄4 coupling.

• Corrosion-proofmagnesiumanode.• Regulationandsafetyrodthermostat;• LEDindicatorlight.

• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.

• CFCandHCFC-freepolyurethane(PU)foam insulation layer.

• IPX4protectivecoveroverelectricalparts(IPX2forversionsV/T50-80-100).

• Storedwatertemperatureindicator.

Power Voltage Heat. time Δt=50°C

Max. operating temp.

Max. operating press.

Net weight

Hydraulic fittings A B

kW V~ min °C MPa kg KW-WW mm mm

1,2 230 153 75 0,8 15,1 R ½ 550 320

1,2 230 245 75 0,8 21,8 R ½ 780 550

1,2 230 306 75 0,8 25,5 R ½ 930 700

5 0

Capacity

l

VD 50 50

VD 80 80

VD 100 100

StandardSERIES 50-80-100

eLeCTRIC WaTeR HeaTeRSwall-hung, storage

Page 51: Style Boiler

WWKW

450

A

100

B072

211

475

WWKW

450A

100

B

072

211

475

054 574

B

A

001 211

072

KW WW

054 574

B

A

001 211

072

KW WW

Wall-hung electric storage water heaters are designed to meet the highest expectations as regards quality in observance of European and international standards. The insulation la-yer is made of very thick high-density polyure-thane (PU) foam to minimise heat loss.

Wall-hung electric storage water heaters are the basic product range devised to ca-ter for the most varied market require-ments. The external control knob (SE) ma-kes for easier adjustment of the watertemperature. Also recommended for in-dustrial and collective use. Also available in the thermo version.

• Steeltank,glass-linedusingtheflow-coatingmethod (850°C).

• Ø134 tank inspection flange.• Corrosion-proofmagnesiumanode.• Armoured copper heating element fitted on a flange.• Externalregulationandsafetycapillary

thermostat.• Externalcasingmadeofsheetmetalcoatedwith

epoxy powder paint.• CFCandHCFC-freeverythickpolyurethane(PU)

foam insulation layer.• LEDindicatorlight.• IPX5protectivecoveroverelectricalparts

complete with cable and plug.• Storedwatertemperatureindicator.

• Steeltank,glass-linedusingtheflow-coat-ing method (850°C).

• Ø88mmtankinspectionflange.• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelementfitted

on a flange.• Regulationandsafetyrodthermostatwith

external control knob.• CFCandHCFC-freepolyurethane(PU)foam

insulation layer.• IPX4protectivecoveroverelectricalparts.• Externalcasingmadeofsheetmetalcoated

with epoxy powder paint.• LEDindicatorlight.• Storedwatertemperatureindicator.

external Control Knob

Capacity Power Voltage Heat. time Δt=50°C

Max. oper. temp.

Max. oper. press.

Net Weight

Hydraulic fittings A B

l kW V~ min °C MPa kg KW-WW mm mm

1,2 230 153 75 0,8 15,5 R ½ 509 281

1,2 230 245 75 0,8 20,5 R ½ 729 498

1,2 230 306 75 0,8 25,5 R ½ 879 648

Capacity Power Voltage Heat. time. Δt=50°C

Insul. thickness

Heat loss 65°C

Max. oper. temp.

Max. oper. press.

Net weight

Hydraulic fittings A B

l kW V~ min mm kWh/24h °C MPa kg KW-WW mm mm

1,2 230 122 ≥25 0,78 75 0,8 18,5 R ½ 513 292

1,2 230 153 ≥25 0,87 75 0,8 21,0 R ½ 596 375

1,2 230 245 ≥25 1,13 75 0,8 27,0 R ½ 799 587

1,2 230 306 ≥25 1,30 75 0,8 33,0 R ½ 1013 801

Note: * = 1.5 and 2.0 kW heating element available

5 1

Capacity

VF 50 Se 50

VF 80 Se 80

VF 100 Se 100

Capacity

ISWV 40 40

ISWV 50 50

ISWV 80 80

ISWV 100 100

Standard topSERIES 40-50-80-100

Standard SESERIES 50-80-100

Note: * = 3.0 kW 230 and 400/3 V~ heating element available, in which case the external control knob SE is no longer required.

eLeCTRIC WaTeR HeaTeRSwall-hung vertical storage

Page 52: Style Boiler

193

B

450

072

100

A

476

112 230

244

B

134

540

156

A

455

WWKWWWKW

Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The external control knob (SE)makesforeasieradjustmentofthewatertemperature.Alsorecommen-ded for industrial and collective use. Also available in the thermo version.

• Steeltank,glass-linedusingtheflow-coating method (850°C).

• Ø88mmtankinspectionflange.• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelement

fitted on a flange.• Regulationandsafetyrodthermostat

with external control knob.• CFCandHCFC-freepolyurethane(PU)

foam insulation layer.

• IPX4protectivecoveroverelectricalparts.

• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.

• LEDindicatorlight.• Storedwatertemperatureindicator.

Accessories on page 60

external Control Knob

version 120 versions 150/200

Capacity Power Voltage Heat. timeΔt=50°C

Max. oper. temp.

Max. oper. press.

Net Weight

Hydraulic fittings A B

l kW V~ min °C MPa kg KW-WW mm mm

1,5 230 294 75 0,8 29,0 R ½ 1029 605

2,0* 230* 275 75 0,8 42,0 R ¾ 945 500

2,0* 230* 367 75 0,8 51,5 R ¾ 1205 800

Note: * = 3.0 kW 230 and 400/3 V~ heating element available, in which case the external control knob SE is no longer required.

5 2

Capacity

VF 120/ Se 120

VF 150/Se 150

VF 200/Se 200

Standard SESERIES 120-150-200

eLeCTRIC WaTeR HeaTeRSwall-hung, storage

Page 53: Style Boiler

WW KW

124

476

A

CD

B

100

270

450

PVPRPR

PV

Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The water heaters are avai-lable in a vertical version, vertical universal left-right thermo version, horizon-tal version and horizontal thermo version.

• Steeltanktreatedwiththermo-hard-ening resins (Teflon) or glass-lined using the flow-coating method (850°C) depending on the model and/or version.

• Armouredcopperheatingelementfitted on a 1 1⁄4 coupling.

• Corrosion-proofmagnesiumanode.• Regulationandsafetyrodthermostat.• LEDindicatorlight.

• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.

• CFCandHCFC-freepolyurethane(PU)foam insulation layer.

• IPX4protectivecoveroverelectricalparts(IPX2forversionsV/T50-80-100).

• Storedwatertemperatureindicator.

Capacity Power Voltage Heat. time. Δt=50°C

Max. oper. temp.

Max. oper. press.

Net weight

Hydraulic fittings

Coil fittings A B C D

l kW V~ min °C MPa kg KW-WW PV-PR mm mm mm mm

1,2 230 153 75 0,8 17,0 R ½ Rp ½ 548 319 229 132

1,2 230 245 75 0,8 23,5 R ½ Rp ½ 779 550 229 363

1,2 230 306 75 0,8 27,5 R ½ Rp ½ 930 701 229 363

5 3

Capacity

VF/T 50 DX/SX 50

VF/T 80 DX/SX 80

VF/T 100 DX/SX 100

Standard termoSERIES 50-80-100

eLeCTRIC WaTeR HeaTeRSwall-hung, storage

Page 54: Style Boiler

PV

PR

PV

PR

193

B

450

072

100

231

250

A

476

112

PV

PR

PV

PR

241

450

230

244

B

134

540

156

A

455

WWKWWWKW

external Control

Knob

Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The external control knob (SE)makesforeasieradjustmentofthewatertemperature.Alsorecommen-ded for industrial and collective use. Also available in the thermo version.

• Steeltank,glass-linedusingtheflow-coating method (850°C).

• Ø88mmtankinspectionflange.• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelement

fitted on a flange.• Regulationandsafetyrodthermostat

with external control knob.• CFCandHCFC-freepolyurethane(PU)

foam insulation layer.

• IPX4protectivecoveroverelectricalparts.

• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.

• LEDindicatorlight.• Storedwatertemperatureindicator

Accessories on page 60

version 120 versions 150/200

Power Voltage Heat. time Δt=50°C

Max. oper. temp.

Max. oper. press.

NetWeight

Hydraulic fittings

Coilfittings

Heat exchange surface

Power (Δt 35 K)**

D.H.W. produc(Δt 35 K)**

Primary flow rate A B

kW V~ min °C MPa kg KW-WW PV-PR m² kW I/h m³/h mm mm

1,5 230 294 75 0,8 37,0 R ½ Rp ½ 0,6 19,0 469 2,0 605 1029

2,0* 230* 275 75 0,8 56,5 R ¾ Rp ½ 0,9 33,0 810 2,0 945 500

2,0* 230* 367 75 0,8 66,0 R ¾ Rp ½ 0,9 33,0 810 2,0 1205 800

Note: * = 3.0 kW 230 and 400/3 V~ heating element available, without control knob **= primary circuit temperature 80°C / secondary circuit temp 10 /45°C / primary flow rate indicated in the table -D.H.W. = domestic hot water.

5 4

Capacity

l

VF/T 120/Se DX120

VF/T 120/Se SXVF/T 150/Se DX

150VF/T 150/Se SXVF/T 200/Se DX

200VF/T 200/Se SX

Standard termo SESERIES 120-150-200

eLeCTRIC WaTeR HeaTeRSwall-hung, storage

Page 55: Style Boiler

WWKW

PR

PVF

H

A B

C R

M L

D

E G S

WWKW

PR

PV

A B S

F

C R

L M

G

D

E

H

Electric water heaters with heat exchanger suitable for solar application, are the basic product range devised to cater the most varied market require-ments. Suitable for collective use.

• ArmoredcopperheatingelementfittedonaØ88mmflangewithsolarsensor sheath included.

• Steeltank,glass-linedusingtheflowcoating method (850° C).

• Corrosion-proofmagnesiumanode• Regulationandsafetyrodthermostat• Indicatorlight.• Externalcasingmadeofsteelsheet

metal coated with epoxy powder paint.

• CFCandHCFC-freepolyurethane(PU)foam insulation layer.

• IPX4protectivecoveroverelectricalparts.

• Storedwatertemperatureindicator• Availablewithleftorrighthydraulic

connections.• Increasedsizecoil.

Versions 60-120 Versions 150-200

newnewStandard with solar coilSERIES 80-100-120-150-200

Power Voltage Heating time (ΔT 50 °C)

Max. operating temperature

Max. operating pressure

Net weight

Hydraulic connections

Coilconnections

Heat Exchange surface

kW V~ min °C MPa kg KW-WW PV-PR m²

1,5 230 23’ 00” 95 0,8 28,5 Rp ½ R ½ 0,6

1,5 230 29’ 00” 95 0,8 33,5 Rp ½ R ½ 0,6

1,5 230 34’ 00” 95 0,8 37,0 Rp ½ R ½ 0,6

2,0 230 30’ 00” 95 0,8 56,0 R ¾ R ½ 0,9

2,0 230 40’ 00” 95 0,8 65,5 R ¾ R ½ 0,9

A B C D E F G H L M R S

mm mm mm mm mm mm mm mm mm mm mm mm

193 305 231 475 450 270 380 100 112 128 250 731

193 455 231 475 450 270 380 100 112 128 250 878,5

193 605 231 475 450 270 380 100 112 128 250 1028,5

243 500 241 555 540 431 486 230 156 118 450 945

243 800 241 555 540 431 486 230 156 118 450 1205

Note: version without heating element, upon request

5 5

VDT/S 80

VDT/S 100

VDT/S 120

VDT/S 150

VDT/S 200

Capacity

l

VDT/S 80 DX80

VDT/S 80 SXVDT/S 100 DX

100VDT/S 100 SXVDT/S 120 DX

120VDT/S 120 SXVDT/S 150 DX

150VDT/S 150 SXVDT/S 200 DX

200VDT/S 200 SX

eLeCTRIC WaTeR HeaTeRSwall-hung storage

Page 56: Style Boiler

337

241

481

WWKW

A

450

B

120 CD

BD C

481

450

A

570

450

120

A481

245

B

358

CD

WW

KWWWKW

BD C

481

450

A

570

450

120

A481

245

B

358

CD

WW

KWWWKW

Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The water heaters are avai-lable in a vertical version, vertical universal left-right thermo version, horizon-tal version and horizontal thermo version.

• Steeltanktreatedwiththermo-hard-ening resins (Teflon) or glass-lined using the flow-coating method (850°C) depending on the model and/or version.

• Armouredcopperheatingelementfitted on a 1 1⁄4 coupling.

• Corrosion-proofmagnesiumanode.• Regulationandsafetyrodthermostat.

• LEDindicatorlight.• Externalcasingmadeofsheetmetal

coated with epoxy powder paint.• CFCandHCFC-freepolyurethane(PU)

foam insulation layer.• IPX4protectivecoveroverelectricalparts(IPX2forversionsV/T50-80-100).

• Storedwatertemperatureindicator.

horizontal versions50-80-100

Power Voltage Heat. time Δt=50°C Max. oper. temp. Max. oper. press. Net Weight Hydraulic fittings A B C D

kW V~ min °C MPa kg KW-WW mm mm mm mm

1,2 230 245 75 0,8 20,5 R ½ 776 272 351 305

1,2 230 306 75 0,8 25,5 R ½ 926 422 380 426

Power Voltage Heat. time Δt=50°C Max. oper. temp. Max. oper. press. Net Weight Hydraulic fittings A B C D

kW V~ min °C MPa kg KW-WW mm mm mm mm

1,2 230 153 75 0,8 15,5 R ½ 545 120 189 236

1,2 230 245 75 0,8 20,5 R ½ 776 272 351 305

1,2 230 306 75 0,8 25,5 R ½ 926 422 380 426

1,2 230 367 75 0,8 29,0 R ½ 1058 520 444 494

2,0 230 275 75 0,8 65,5 R ¾ 1024 530 238 256

2,0 230 367 75 0,8 71,5 R ¾ 1294 800 238 256

Note: heating element fitting left or right.

versions 150/200

version 120

5 6

Capacity

l

OD 80 DX80

OD 80 SXOD 100 DX

100OD 100 SX

Capacity

l

OF 50 DX50

OF 50 SXOF 80 DX

80OF 80 SXOF 100 DX

100OF 100 SXOF 120 DX

120OF 120 SXOF 150 DX/SX 150

OF 200 DX/SX 200

Standard horizontalSERIES 50-80-100-200

eLeCTRIC WaTeR HeaTeRSwall-hung, horizontal storage

Page 57: Style Boiler

A

140

200

120

481

362

245

450

D

CB

PV

PR

WWKW

Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The water heaters are avai-lable in a vertical version, vertical universal left-right thermo version, horizon-tal version and horizontal thermo version.

• Steeltanktreatedwiththermo-hard-ening resins (Teflon) or glass-lined using the flow-coating method (850°C) depending on the model and/or version.

• Armouredcopperheatingelementfitted on a 1 1⁄4 coupling.

• Corrosion-proofmagnesiumanode.• Regulationandsafetyrodthermostat.

• LEDindicatorlight.• Externalcasingmadeofsheetmetal

coated with epoxy powder paint.• CFCandHCFC-freepolyurethane(PU)

foam insulation layer.• IPX4protectivecoveroverelectricalparts(IPX2forversionsV/T50-80-100).

• Storedwatertemperatureindicator.

Power Voltage Heat. time. Δt=50°C

Max. oper.temp

Max. oper. press

Net Weight

Hydraulic fittings

Coil fittings A B C D

kW V~ min °C MPa kg KW-WW PV-PR mm mm mm mm

1,2 230 245 75 0,8 26,5 R ½ Rp ½ 807 370,5 316,5 220

1,2 230 306 75 0,8 31,6 R ½ Rp ½ 930 418,5 391,5 370

5 7

Capacity

l

OF/T 80 DX80

OF/T 80 SX

OF/T 100 DX100

OF/T 100 SX

Standard horizontal termoSERIES 80-100

eLeCTRIC WaTeR HeaTeRSwall-hung, storage horizontal

Page 58: Style Boiler

Z

A B

DE

F

C

WW

KW

Floor-standing electric storage water heaters are designed to meet the hi-ghest expectations as regards quality in observance of European and interna-tional standards. The insulation layer is made of very thick high-density polyu-rethane (PU) foam to minimise heat loss. They are ideal for collective and industrial use.

• Steeltank,glass-linedusingtheflow-coating method (850°C).

• Ø134mmfrontinspectionhatch.• Corrosion-proofmagnesiumanode.• Armouredcopperheatingelement

fitted on the hatch.• Regulationandsafetythermostat.• Externalcolouredplastic(PVC)

coating.

• CFCandHCFC-freeverythickpolyurethane (PU) foam insulation layer.

• IPX5protectivecoveroverelectricalparts.

• Storedwatertemperatureindicator.

Accessories on page 60

Capacity Power Voltage Heat. Time. Δt=50°C

Insul. thickness

Heat loss 65°C

Max. oper. temp.

Max. oper. press.

Net weight

Hydraulic fittings Recirculation A B C D E F

l kW V~ min mm kWh/24h °C MPa kg KW-WW Z mm mm mm mm mm mm

1,5 230 294 ≥50 1,50 75 1,0 38 Rp ¾ Rp ¾ 610 620 854 150 486 720

2,0 230 294 ≥50 1,70 75 1,0 46 Rp ¾ Rp ¾ 610 620 1056 150 551 922

2,0 230 367 ≥50 2,00 75 1,0 53 Rp ¾ Rp ¾ 610 620 1329 150 651 1195

3,0 230 367 ≥50 2,40 75 1,0 77 Rp 1 Rp 1 650 675 1560 148 828 1408

3,0 400/3 367 ≥50 2,40 75 1,0 77 Rp 1 Rp 1 650 675 1560 148 828 1408

4,0 400/3 367 ≥50 2,80 75 1,0 99 Rp 1 Rp 1 750 775 1553 162 782 1387

5,0 400/3 367 ≥50 3,30 75 1,0 115 Rp 1 Rp 1 750 775 1818 162 932 1652

5,0 400/3 440 ≥50 3,60 75 1,0 176 Rp 1 Rp 1 810 832 1819 124 871 1659

5 8

Capacity

l

ISS 120 120

ISS 160 160

ISS 200 200

ISS 300 300

ISS 300/3 300

ISS 400/3 400

ISS 500/3 500

ISS 600/3 600

InterlineSERIES 120-160-200-300-400-500-600

eLeCTRIC WaTeR HeaTeRSfloor-standing, storage

Page 59: Style Boiler

KW

Z

WW

D

E

F

C

A B

• Glass-linedsteelboiler.• DoubleØ134mmfronthatchwayfor

electrical Kit assembly and inspection.• Ø134mmtopbottom-flange

complete with counter-flange.• Verythickexpandedpolyurethane

(PU) / (EPS) insulation layer. “Easy entry” system.

• Externalcolouredplasticcoating.• Adjustablefeetforfloorstanding.• Storedwatertemperatureindicator

Accessories on page 60

Floor-standing electric storage water heaters are designed to meet the new expectations of the market as to durability and great storage. To this end, this new high-capacity product line was introduced, providing maximum quality and durability owing to the use of special materials and sophisticated techno-logical solutions. The guarantee of durability in time is further extended by means of a modern “glass-lining” treatment over the tank. The insulation layer is manufactured by means of a new system that combines the technology of theinjectedpolyurethane(PU)withtheflexibilityofNEOPOR(EPS).Thissolu-tion allows the installer to have a “plug and play” product and, in case of need, it is an easy solution for making the product pass through openings whose width equals 800 mm. This system allows a trouble-free disassembly and re-assembly of the insulation layer for an easier installation in boiler rooms. The two big front hatchways characterise the line of these products and make them flexible and suitable for several combinations of electrical powers up to maximum 20 kW. The electrical components are supplied apart in handy sin-gle- and three-phase KITs with Incoloy 800 stainless steel heating elements with powers up to 10 kW or made of copper up to 5 kW. Furthermore, you can equip the tank with spiroid exchangers, if any, which can be installed in the hatchways. They are recommended for collective use.

INOX Stainless Steel Heating element KIT

Capacity Insul. thickness

Max. oper. temp.

Max. oper. press.

Net Weight

Hydraulicfittings Recirculation A B C D E F

l mm °C MPa kg KW-WW Z mm mm mm mm mm mm

>100 75 1,0 146 Rp 1 ¼ Rp 1 ¼ 880 925 1865 191 1071 1676

>100 75 1,0 170 Rp 1 ¼ Rp 1 ¼ 880 925 2245 191 1263 2056

5 9

Capacity

l

ISS 800 800

ISS 1000 1000

Interlinehigh storageSERIES 800-1000

eLeCTRIC WaTeR HeaTeRSstorage type, floor-standing

Page 60: Style Boiler

accessories & kit for electric water heatersCODe DeSCRIpTION

070513 SINGLE-, THREE-PHASE TRANSFORMATION ELECTTRICAL KITONLY FOR SERIES V E V/T 150-200formedby:2”heatingelement-3.0kw-400/3V~installedontheflange, flange gasket, three-phase thermostat and closing cover.

070265 2.0 kW 230 V~ 1” SINGLE-PHASE ELECTRICAL KIT formed by: counter-flange with 1” sleeve, gasket, copper armoured heating element and thermostat.

070266 3.0 kW 230 V~ 1” SINGLE-PHASE ELECTRICAL KIT formed by: counter-flange with 1” sleeve, gasket, copper armoured heating element and thermostat

070267 3.0 kW 400/3 V~ 2” THREE-PHASE ELECTRICAL KITformed by: counter-flange with 2” sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectorsNot suitable for 800 L and 1000 L models.

070268 4.0 kW 400/3 V~ 2” THREE-PHASE ELECTRICAL KIT~ formed by: counter-flange with 2” sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectorsNot suitable for 800 L and 1000 L models

070269 5.0 kW 400/3 V~ 2” THREE-PHASE ELECTRICAL KIT formed by: counter-flange with 2” sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectorsNot suitable for 800 L and 1000 L models

070137 3,0÷6,0 kW 400/3 V~ THREE-PHASE INOX ELECTRICAL KIT formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket RECOMMENDED FOR SERIES 400-500-600-800-1000

070138 4.0÷8.0 kW 400/3 V~ THREE-PHASE INOX ELECTRICAL KIT formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. RECOMMENDED FOR SERIES 400-500-600-800-1000

070136 5.0÷10.0 kW 400/3V~ THREE-PHASE INOX ELECTRICAL KIT formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. RECOMMENDED FOR SERIES 400-500-600-800-1000

030528 SPIROID EXCHANGER KIT 1.0 sqmFOR ALL SERIES formed by: counter-flange, finned coil made of tinned copper 1 sqm; gasket, union set, round grill, fastening screws and nuts

030525 SPIROID EXCHAGER KIT 1.8 sqm ONLY FOR SERIES 400-500-600-800-1000formed by: counter-flange, finned coil made of tinned copper 1.8 sqm; gasket, union set, round grill, fastening screws and nuts

6 0

STANDARD

INTERLINE

INTERLINE

FREE STANDING

INTERLINE

eLeCTRIC WaTeR HeaTeRS

Page 61: Style Boiler

Thermal insulationInsulation layer made of very thick (range for collective use) high-density polyurethane (PU) foam that guarantees excellent insula-tion.

Tank protection against wearThanks to the “flow-coating” enamelling pro-cess at 850°C for guaranteed quality internal protection or via classic hot galvanising process(forseries600-2000only).

Magnesium anodeFeatured in all the models in the range, this anode makes for effective electrochemical tank protection.

Environmentally friendlyWe strive to optimise its industrial activity while respecting the environment. To mini-mise the environmental impact of its pro-ducts, it has abolished the use of chlorofluo-rocarbons (CFC-HCFC) in the insulation layer and makes continuous efforts to use recycla-ble components.

The “STReNGTHS” of the product range in detail:

6 1

We have come up with an appliance that fully exploits the natural energy released by a fuel deemed to be “poor”, namely wood, turning it into a precious source of energy that is easily exploited. Using a Styleboiler wood-fired water heater, alone or combined with an electric heating element, means having heat available at a low cost and in an environmentally-friendly way. The models available are devised for a prevalently domestic use, with a design marked by eco-friendly choices to help protect the environment. In fact, wood as a resource is a renewable and eco-compatible energy source. Our choice of wood as the fuel, which affects several sectors of the eco-nomy such as forestry and agriculture, which have the possibility of recovering millions of hectares of abandoned and deteriorated land, automatically makes for a sustainable development with the expan-sion of woodland crops. TheADVANTAGESofthissystementailthepossibilityofusingrenew-able natural resources, with the maximum practicality at limited costs, all this with a straightforward installation process that requires no elec-trical connections.

Wood-fired water heaters

Page 62: Style Boiler

98100 28

063

1468

WW KW WW KW

VP

RP

2898

100063

1468

613

450

Wood-fired

“Wood-fired” storage water heaters are designed to produce water where tra-ditional sources of energy are unavailable or simply to use renewable forms of energy while respecting the environment. Electric or thermo-electric versions are available.

• Steeltank,glass-linedusingtheflow-coating method (850°C).

• Corrosion-proofmagnesiumanode.• Combustionchambermadeof

refractory material with pull-out ash collecting device.

• Enamelledsheetmetalexternalcombustion chamber coating.

• Mineralwoolinsulationlayerforreduced heat loss.

• Armouredcopperheatingelement,regulation and safety rod thermostat (wood-electric version only).

• Externalcasingmadeofsheetmetalcoated with epoxy powder paint.

• Storedwatertemperatureindicator.• Electricandthermo-electricversions

available.

Wood-fired / wood-electric version Wood-fired / wood-thermoelectric version

Capacity Power Voltage Heat. time Δt=50°C

Max. operating temp.

Max. operating press.

Net Weight Hydraulic fittings Coil

fittings

l kW V~ min °C MPa kg KW-WW PV-PR

- - - 90 0,8 46 R ½ -

1,2 230 245 90 0,8 46 R ½ -

1,2 230 245 90 0,8 49 R ½ Rp ¾

6 2

Capacity

l

LG 80

LGe 80

LGe/T 80

Note: LG = wood-fired version / LGE = wood-electric version / LGE/T = thermo-electric wood version

WOOD-FIReD WaTeR HeaTeR

Page 63: Style Boiler

General remarks

6 3

Styleboiler is in a position to boast a consolidated experience in the challenging world of protective coatings for steel tanks devised to store domestic hot water, thanks to over twenty years of doing business in the design and manufacture of storage water heaters for the production of hot water.

The range Styleboiler offers an extensive range of electric, gas and wood-fired storage water heaters and indirect cylinders to cater for all hot water requirements, both at home as well as in industrial or communal settings. The classical product range including boilers manufactured with glass-lined steel has been joined by a renewed and complete product line, which includes stainless steel boilers. The company’s policy, which aims at implementing technologies that do not affect the ecosystem, has led to the design and manufacture of new models that utilise renewable energy sources, such as “heat pumps”. Owing to this wide range of models, Styleboiler can cover a spectrum of capacities ranging from 10 to over 2.000 litres to guarantee the maximum comfort and well-being of end users.

Quality, safety and flexibilityStyleboiler has always stood for quality; the excellent quality of Styleboiler products is the result of an accurate design process combined with the use of advanced technologies, of carefully selected raw materials, and it is guaranteed by regular checks carried out at every stage of the manufacturing process. Product safety is guaranteed by the observance of applicable laws and product standards, along with the prestigious ISO 9001/2000 certification, which enable Styleboiler to accommodate the needs of the most demanding international markets. Flexibility is another feature that makes Styleboiler the best possible partner for its strong focus on the partnership with its customers, offering customised solutions wherever required.

All STYLEBOILER appliances conform to European Di-rectives. The gas appliances are devised and specifical-ly approved for the use of

standard fuels. All STYLEBOILER appliances made at the S.Maria di Zevio (VR) plant are designed and built in compliance with international quality standards ISO 9001/2000 and conform to article 3.3 of European Directive 97/23/EEC (PED).

Installation and use These appliances are approved for indoor installation only. Installation must be per-formed and certified by authorised techni-cians only, in accordance with the law. A “hydraulic safety group” compliant with EN 1487 or the equivalent must be fitted on all appliances. The water tempera-ture adjustment allows the energy con-sumption to be optimised according to the well-being required. However, it is advisable to prevent the temperature of the water stored from being too low, in order to avoid the prolife-ration of bacteria that cause Legionnaire’s disease. To this end, here are a few general precautions to take: • Keepthehotwaterinsidetheapplian-ce at a temperature of no less than 50 °C;• In the event of prolonged absen-ces, allow water to run freely from taps and showers for a few minutes;• Keepshowerheadsandtapsfreeofli-mescale build-ups. The manufacturer will not be held liable in the event of uses other than those speci-fied.

Technical characteristicsAs STYLEBOILER constantly strives to im-prove its products, the company reserves the right to make changes to the technical characteristics and to discontinue models illustrated in this catalogue without prior notice. The details are purely indicative and are included to help you choose the right ap-pliance for your needs. In addition, the ma-nufacturer denies all responsibility in the event of printing or transcription errors.

GuaranteeSTYLEBOILER guarantees the correct ope-ration of its appliances according to the methods stated on the guarantee certi-ficates included with the appliances and always in compliance with the applicable Laws in force.

Page 64: Style Boiler

Gruppo Giona S.p.A.

Via Apollo 11, 1 - 37059 S. Maria di Zevio (Verona) - Italy

tel. +39 045 6050099 r.a. - fax +39 045 6050124

www.styleboiler.it

Production site:

Via Apollo 11, 137059 S. Maria di Zevio (Verona) - Italy

Loc. Oliero di Sotto36020 Valstagna (Vicenza) - Italy

Via C. Grazioli 27/A29012 Caorso (Piacenza) - Italy

Internal boiler protection treatments:

ZIAC S.p.A.Loc. Speranza37059 S. Maria di Zevio (Verona) - Italy

Branches:

Styleboiler AG/SA/LTDNordweg 16 - Chemin du nord 1602502 Biel/Bienne - Switzerland

Style System Technik GmbhLeinenweberstraße, 8 48317 Drensteinfurt - Germany

Italian technology and quality

03-201

1IN

GLESE

ww

w.s

tudi

ocam

elot

.it