Structural Feasibility Report of Dh1539b

Embed Size (px)

Citation preview

  • 7/30/2019 Structural Feasibility Report of Dh1539b

    1/7

    DH1539B Type of Site:OUTDOOR

    INDOOR (PU Cabin)

    INDOOR (BRICK) R1

    AIRTEL OUTDOOR R2

    R3

    R1

    10-Jan-13

    STRUCTURAL FEASIBILITY REPORT WITH RECOMMENDATION

    Region

    Date

    RECOMMENDATION

    TOWER

    /POLE

    HEIGHT (m)

    LOCATION

    OF TOWER/

    POLE (m )

    Site ID:

    Address

    Project

    ARRANGEME

    NT OF

    TOWER

    TOTAL

    HEIGHT

    (m)

    GENERATOR

    POSITION

    WIND SPEED 210 KPH, 6.0M POLES WITH OUTDOOR

    OPTION REMARKSSELECTED

    (YES/N0)

    Arun Alo, H#79, Cercular road, Siddeswari, Dhaka-1217.

    Remarks:

    Signature

    M/24108

    RAJUK NO-DMINB/CE-0334

    Company Name

    Prudential Consultant

    Address TOWER EXISTING ROOF TOPGa, 40/5, Shahjadpur, Gulshan, Dhaka-1212. POLE EXISTTING GROUND FLOOR

    E 20 EXISTING ROOM

    A 6 BESIDE BUILDING

    B 9 NOT AVAILABLE

    C 12

    D 15

    E 20

    F

    Md. Saiful Hoque Sohel

    YES

    MIEB NO.

    Name of the Engineer

    NOT AVAILABLE36POLE306

    IT IS RECOMMENDED TO BUILD MENTIONING TOWER/POLE

    B SAFE

  • 7/30/2019 Structural Feasibility Report of Dh1539b

    2/7

    Site ID DH1539B

    Address Arun Alo, H#79, Cercular road, Siddeswari, Dhaka-1217.

    Project AIRTEL

    Date 10-Jan-13

    Uplift Down force Share Uplift Down force Share

    WIND

    SPEED

    85

    TOWER/ POLE REACTION

    CRITICAL COLUMN C27(SEE DRAWING) BRIEF ANALYSIS

    WIND SPEED 210 KPH, 6.0M POLES WITH OUTDOOR

    85

    LEG TO LEG

    DISTANCE

    GENERAL INFORMATION

    Un factored (KN) Factored(KN)TOWER/

    POLE TYPE

    6M POLE 2.5 210KPH 12

    UNIT SYSTEM MKSUSD ACCORDING TO BANGLADESH NATIONAL BUILDING CODE

    (BNBC)1993,UBC 1997

    WEIGHT OF EQUIPMENT

    ITEMRBS-2206(IDU)

    RBS-2106(ODU)

    SIZE (MM) WEIGHT(KG )600X 400 X1850 230 kg

    FIRE EXTINGUISHER

    620 X 300 X 900 100 kg

    400 X 350 X 250 15 kg

    SDH

    MDB

    ROXTEC 4X6 294 X 665 20 kg

    KRONE 450 X 220 X 125 5 kg

    AC INDOOR UNIT 1100 X 290 X 300

    800 kg

    20 kg

    GENSET (FG WILSON) 1684 X 860 X 1453 721 kg

    ROXTEC 3X6 294 X 550 20 kg

    GENSET (PARAMAC) 2000 X 920 X 1300 875 kg

    TRANSMISSION RACK 600 X 600 X 1650 50 kg

    500X 1000 X 21001294 X 846 X 480

    750 X 500 X 210 15 kg

    PBC 6500 RECTIFIER 600 X 400 X 1917

    BBU (8 BATTERIES)

    1300 X 925 X 1617 685 kg

    597 kg50 kg

    5 kg

    DESIGN METHOD

    AVR

    FMS

  • 7/30/2019 Structural Feasibility Report of Dh1539b

    3/7

    Force kN Flexure 0.90

    Distance m Tension 0.90Moment kN-m Shear & Torsion 0.85

    Area sqm Bearing on Concrete 0.70

    Unit Weight kN/cum

    Member Dimension mm

    PressureN/sqmm

    (Mpa)

    Unit Weight of RCC 23.60 kN/cum

    Dead Load 1.40 Unit Weight of Brick 18.86 kN/cum

    Live Load 1.700 FF 0.5 kN/sqm

    Equipment Load 1.00 kN

    Concrete strength fc'

    20.60 Mpa Generator Load 1.00 kNSteel strength fy 400.00 Mpa Live Load 2.00 kN/sqm

    Load factors

    Strength of Materials

    General Information

    Load Consideration

    Strength Reduction factorUNIT

    No. of Floors 10 No(s) No. of Floors No(s)

    Height of Floors 3 m Height of Floors m

    Height of Brick Wall 2.6 m Height of Brick Wall m

    Thickness of Brick Wall 125 mm Thickness of Brick Wall mm

    Column Dimension Column Dimension

    Width 425 mm Width mmBreadth 300 mm Breadth mm

    Beam Dimension Beam Dimension

    Depth 400 mm Depth mm

    Width 250 mm Width mm

    Slab Dimension Slab Dimension

    Length, a 5.4 m Length, a m

    Length, b 2.43 m Length, b m

    Length, c 3.6 m Length, c m

    Length, d 4 m Length, d m

    Thickness of Slab 160 mm Thickness of Slab mm

    Column (form PL to Top of Footing) Beam DimensionLength m Length m

    Width 475 mm Depth 375 mm

    Breadth 350 mm Width 300 mm

    Footing Dimension Slab Dimension

    Length m Lenghth, a m

    Width m Lenghth, c m

    Depth mm Thickness of Slab 125 mm

    Equimpent room Information

    Foundation Informatin Generator Installation Structrue

    Building Information

  • 7/30/2019 Structural Feasibility Report of Dh1539b

    4/7

    A. Load From Existing BuildingLoad from Slab

    Effective area 14.88 sqm

    SW 56.18 kN

    FF 7.44 kN

    Load from Beam

    Effective Length 7.72 m

    SW 3.93 kN

    Partition Wall 47.29 kN

    Load from Column

    SW 9.03 kNLoad per Floor 123.86 kN

    Total Number of floor 10 No(s)

    Calculation of Load

    Dead Laod

    Load on critical column upto GL from Existing Building 1238.63 kN

    B. Load from Equipment room

    Load from Slab

    Effective area 0.00 sqmSW 0.00 kN

    FF 0.00 kN

    Load from Beam

    Effective Length 0.00 m

    SW 0.00 kN

    Partition Wall 0.00 kN

    Load from Column

    SW 0.00 kN

    Load on critical column From Equipment Room 0.00 kN

    C. Load From Generator Installation structure

    Beam 0.00 kNSlab 0.00 kN

    Load on critical columnfrom Generator Installation stucture 0.00 kN

    D. Load on critical column from PL to Face of Footing (SW) 0.00 kN

  • 7/30/2019 Structural Feasibility Report of Dh1539b

    5/7

    E. Load From Antenna support Structure

    (Analysis by Moment Distribution method or STAAD.Pro or by any other software )

    Load on Critical Column from Antenna Support Structure 85.00 kN

    Total DL on Footing 1238.63 kN

    Live Load

    F. Load from Existing Building

    Effective area 14.88 sqm

    Load per Floor 29.75 kN

    Total Number of floor 10 No(s)

    Load on critical column from Existing Building 297.54 kN

    G. Load from Equipment room

    Effective area 0.00 sqm

    Load on critical column from Equipment room 0.00 kN

    H. Load on critical column from Generator 0.00 kN

    Total LL on Critical Column 297.54 kN

    Other Load

    I. Load from Appendix 1

    J. Load from Appendix 2

    Total Load on critical column from Other sourced 0.00 kN

    Total Load on Critical Column

    2324.90 kN

    520.78 Kip

    1.4DL + 1.7LL + TL+ Other Load

  • 7/30/2019 Structural Feasibility Report of Dh1539b

    6/7

    Serial No. Load Source Load TypeUnfactored

    (kN)

    Factored

    (kN)

    DEAD LOAD = 1238.63 1734.08LIVE LOAD = 297.54 505.82

    DEAD LOAD = 0.00 0.00

    LIVE LOAD = 0.00 0.00

    DEAD LOAD = 0.00 0.00

    LIVE LOAD = 0.00 0.00

    4Load from PL to face of

    footingDEAD LOAD = 0.00 0.00

    Loadfrom equimpment

    room

    3

    Load from Existing Building

    Load from Generator

    Installation structure

    1

    2

    Summary of Load Calculation :

    5 Load from Antenna support Tower Load = 70.83 85.00

    6 Load from Other sources MISC = 0.00

    TOTAL LOAD ON CRITICALLY LOADED COLUMN: 1607.00 2324.90

    7 Load from Self Weight of Dead Load = 0 0.00

    1607.00 2324.90

    17.48

    TOTAL LOAD ON SOIL:

  • 7/30/2019 Structural Feasibility Report of Dh1539b

    7/7

    STRENGTH REDUCTION FACTOR, 0.70COLUMN SIZE Width 475.00 mmBreadth 350.00 mm

    REBAR :

    ReBar Size (mm) 16.00 20 22 25

    ReBar Area (sqmm) 201.06 314.16 380.13 490.87

    b) BAR NO.

    c) TOTAL BAR AREA AS 3325.00 sqmm

    Concrete strength fc' 20.60 Mpa

    Steel strength fy 400.00 Mpa

    MAXIMUM ALLOWABLE: AXIAL LOAD 2342.38 KN OK

    REPORT SUMMARY

    1. COLUMN CAPACITY CALCULATION:

    2. PUNCHING SHEAR CHECK N/AVALUE OF STRENGTH REDUCTION FACTOR, COLUMN SIZE Width

    Breadth

    FOOTING SIZE

    LengthWidth

    Depth

    Effective Depth

    MAXIMUM ALLOWABLE: AXIAL LOA

    3. BEARING CAPACITY of SOILFOOTING SIZE

    Length

    Width

    Area

    Load on SOIL

    Allowable Capacity of Soil

    F.S.