STP17000TL-DEN130517w

Embed Size (px)

Citation preview

  • 7/27/2019 STP17000TL-DEN130517w

    1/4

    Economical Maximum efficiency of 98.2 % SMA OptiTrac Global Peak

    MPP tracking for best MPP trackingefficiency

    Bluetooth

    communication

    Flexible DC input voltage up to 1000 V Integrated grid management

    functions Custom plant design with Optiflex

    Simple Three-phase feed-in Cable connection without tools SUNCLIX DC plug-in system Easily accessible connection area

    Reliable Triple protection with Optiprotect: Electronic string fuse Self-learning string failure detection DC surge arrester (Type II) can

    be integrated

    SUNNY TRIPOWER10000TL / 12000TL / 15000TL / 17000TLThe three-phase inverter for easy plant design

    Full of pioneering technology: highly flexible plant design with the three-phase Sunny Tripower inverter. Thanks to Optiflextechnology, two MPP inputs and a broad input voltage range, it is suited to almost any module configuration. It meets any

    requirement such as reactive power supply, grid support thus reliably participating in grid management. The safety conceptOptiprotect with its self-learning string-failure detection, electronic string fuse and integrable DC surge arrester type II, ensuresmaximum availability.

    SUNNY TRIPOWER10000TL / 12000TL / 15000TL / 17000TL

    S T P 1 0 0 0 0 T - 1

    0 /

    S T P 1 2 0 0 0 T L - 1

    0 /

    S T P 1 5 0 0 0 T L - 1

    0 /

    S T P

    1 7 0 0 0 T L - 1

    0

  • 7/27/2019 STP17000TL-DEN130517w

    2/4

    SUNNY TRIPOWER10000TL / 12000TL / 15000TL / 17000TL

    Input (DC)Max. DC power (@ cos =1)Max. input voltageMPP voltage range / rated input voltageMin. input voltage / initial input voltageMax. input current input A / input BMax. input current per string input A2 / input B2

    Number of independent MPP inputs / strings per MPP inputOutput (AC)Rated power (@ 230 V, 50 Hz)Max. apparent AC power Nominal AC voltage

    Nominal AC voltage range

    AC power frequency / rangeRated grid frequency / rated grid voltageMax. output currentPower factor at rated power Adjustable displacement factor Phase conductors / connection phasesEffi ciencyMax. effi ciency / European effi ciencyProtectionInput-side disconnection deviceGround-fault monitoring / grid monitoringDC surge arrester Type II, can be integratedDC reverse-polarity protection / AC short-circuit current capability / galvanically isolatedAll-pole sensitive residual current monitoring unitProtection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1)

    General DataDimensions (W / H / D)

    WeightOperating temperature rangeNoise emission (typical)Self-consumption at nightTopology / cooling conceptDegree of protection (according to IEC 60529)Climatic category (according to IEC 60721-3-4)Maximum permissible value for relative humidity (non-condensing)FeaturesDC terminal / AC terminalDisplayInterface: RS485 / Bluetooth / Speedwire / WebconnectMulti-function relay / Power Control ModuleWarranty: 5 / 10 / 15 / 20 / 25 yearsCerticates and approvals (more available on request)

    Type designation

    Technical DataSunny Tripower

    12000TLSunny Tripower

    10000TL

    10200 W1000 V

    320 V 800 V / 600 V150 V / 188 V22 A / 11 A

    33 A / 12.5 A2 / A:4; B:1

    10000 W10000 VA

    3 / N / PE; 220 / 380 V3 / N / PE; 230 / 400 V3 / N / PE; 240 / 415 V

    160 V 280 V

    50 Hz, 60 Hz / 6 Hz +5 Hz50 Hz / 230 V16 A

    10.8 overexited 0.8 underexited

    3 / 3

    98.1 % / 97.7 %

    /

    / /

    I / III

    665 / 690 / 265 mm(26.2 / 27.2 / 10.4 in)

    59 kg (130.07 lb)25 C +60 C (13 F +140 F)

    51 dB(A)1 W

    Transformerless / OptiCoolIP65

    4K4H100 %

    SUNCLIX / Spring-type terminalGraphic

    / / / /

    / / / /

    STP 10000TL-10

    12250 W1000 V

    380 V 800 V / 600 V150 V / 188 V

    22 A / 11 A33 A / 12.5 A

    2 / A:4; B:1

    12000 W12000 VA

    3 / N / PE; 220 / 380 V3 / N / PE; 230 / 400 V3 / N / PE; 240 / 415 V

    160 V 280 V

    50 Hz, 60 Hz / 6 Hz +5 Hz50 Hz / 230 V19.2 A

    10.8 overexited 0.8 underexited

    3 / 3

    98.1 % / 97.7 %

    /

    / /

    I / III

    665 / 690 / 265 mm(26.2 / 27.2 / 10.4 in)

    59 kg (130.07 lb)25 C +60 C (13 F +140 F)

    51 dB(A)1 W

    Transformerless / OptiCoolIP65

    4K4H100 %

    SUNCLIX / Spring-type terminalGraphic

    / / / /

    / / / /

    STP 12000TL-10

    AS 4777, BDEW 2008, C10/11, CE, CEI 0-21, EN 50438 1, G59/2,IEC61727, PPC, PPDS, RD 1699, RD 661/2007, SI4777, UTE C15-712-1,

    VDE 0126-1-1, VDE-AR-N 4105

  • 7/27/2019 STP17000TL-DEN130517w

    3/4

    Accessories

    Input (DC)Max. DC power (@ cos =1)Max. input voltageMPP voltage range / rated input voltageMin. input voltage / initial input voltageMax. input current input A / input BMax. input current per string input A2 / input B2

    Number of independent MPP inputs / strings per MPP inputOutput (AC)Rated power (@ 230 V, 50 Hz)Max. apparent AC power Nominal AC voltage

    Nominal AC voltage range

    AC power frequency / rangeRated grid frequency / rated grid voltageMax. output currentPower factor at rated power Adjustable displacement factor Phase conductors / connection phasesEffi ciencyMax. effi ciency / European effi ciencyProtectionInput-side disconnection deviceGround-fault monitoring / grid monitoringDC surge arrester Type II, can be integratedDC reverse-polarity protection / AC short-circuit current capability / galvanically isolatedAll-pole sensitive residual current monitoring unitProtection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1)

    General DataDimensions (W / H / D)

    WeightOperating temperature rangeNoise emission (typical)Self-consumption at nightTopology / cooling conceptDegree of protection (according to IEC 60529)Climatic category (according to IEC 60721-3-4)Maximum permissible value for relative humidity (non-condensing)FeaturesDC terminal / AC terminalDisplayInterface: RS485 / Bluetooth / Speedwire / WebconnectMulti-function relay / Power Control ModuleWarranty: 5 / 10 / 15 / 20 / 25 yearsCerticates and approvals (more available on request)

    Type designation

    Technical DataSunny Tripower

    15000TLSunny Tripower

    17000TL

    15340 W1000 V

    360 V 800 V / 600 V150 V / 188 V33 A / 11 A

    40 A / 12.5 A2 / A:5; B:1

    15000 W15000 VA

    3 / N / PE; 220 / 380 V3 / N / PE; 230 / 400 V3 / N / PE; 240 / 415 V

    160 V 280 V

    50 Hz, 60 Hz / 6 Hz +5 Hz50 Hz / 230 V24 A

    10.8 overexited 0.8 underexited

    3 / 3

    98.2 % / 97.8 %

    /

    / /

    I / III

    665 / 690 / 265 mm(26.2 / 27.2 / 10.4 in)

    59 kg (130.07 lb)25 C +60 C (13 F +140 F)

    51 dB(A)1 W

    Transformerless / OptiCoolIP65

    4K4H100 %

    SUNCLIX / Spring-type terminalGraphic

    / / / /

    / / / /

    STP 15000TL-10

    17410 W1000 V

    400 V 800 V / 600 V150 V / 188 V

    33 A / 11 A40 A / 12.5 A

    2 / A:5; B:1

    17000 W17000 VA

    3 / N / PE; 220 / 380 V3 / N / PE; 230 / 400 V3 / N / PE; 240 / 415 V

    160 V 280 V

    50 Hz, 60 Hz / 6 Hz +5 Hz50 Hz / 230 V24.6 A

    10.8 overexited 0.8 underexited

    3 / 3

    98.2 % / 97.8 %

    /

    / /

    I / III

    665 / 690 / 265 mm(26.2 / 27.2 / 10.4 in)

    59 kg (130.07 lb)25 C +60 C (13 F +140 F)

    51 dB(A)1 W

    Transformerless / OptiCoolIP65

    4K4H100 %

    SUNCLIX / Spring-type terminalGraphic

    / / / /

    / / / /

    STP 17000TL-10

    RS485 interfaceDM-485CB-10

    DC surge arrester (Type II),input ADCSPD KIT1-10

    DC surge arrester (Type II),inputs A and BDCSPD KIT2-10

    Power Control ModulePWCMOD-10

    Multi-function relayMFR01-10

    Speedwire/Webconnectinterface SWDM-10

    1 Does not apply to all national deviations of EN 504382 To be observed in case of a short circuit in the electronic string fuse

    Standard features Optional features Not availableData at nominal conditionsProvisional data, as of January 2013

    AS 4777, BDEW 2008, C10/11, CE, CEI 0-21, EN 50438 1, G59/2,IEC61727, PPC, PPDS, RD 1699, RD 661/2007, SI4777, UTE C15-712-1,

    VDE 0126-1-1, VDE-AR-N 4105

  • 7/27/2019 STP17000TL-DEN130517w

    4/4

    SMA Solar Technologywww.SMA-Solar.com S T P 1 7 0 0 0 T L

    - D E N 1 3 0 5 1 7 S M A a n

    d S u n n y

    T r i p o w e r a r e r e g i s t e r e d

    t r a d e m a r

    k s o f

    S M A S o l a r

    T e c h n o

    l o g y

    A G

    . B l u e t o o

    t h i s a r e g i s t e r e

    d t r a d e m a r

    k o w n e

    d b y B l u e

    t o o t

    h S I G

    , I n c . S

    U N C L I X i s a r e g

    i s t e r e

    d t r a d e m a r k o w n e

    d b y P H O

    E N I X C O N T A C T G m

    b H & C o .

    K G . T

    e x t a n d

    i l l u s

    t r a t i o n s r e

    f l e c t

    t h e c u r r e n

    t s t a t e o f

    t h e

    t e c h n o l o g y a t

    t h e

    t i m e o f p u b

    l i c a t

    i o n .

    T e c h n i c a

    l m o d

    i f i c a

    t i o n s r e s e r v e d . N

    o l i a b i l i t y f o r p r i n

    t i n g e r r o r s . P

    r i n t e d o n c h

    l o r i n e -

    f r e e p a p e r .

    www.SunnyPortal.comProfessional management, monitoring and presentation of PV plants