FIREBARRIER
SILICONE SL
INTUMESCENT SEALANT INSERTS OR PUTTY PADSFOR ELECTRICAL BOXES
MORTAR
CPVC/PVC/ABS PLASTIC PIPE
STEEL, IRON & COPPER METALLIC PIPE
MINERAL WOOLMINERAL WOOLSILICONE
ACRYLIC SEALANT ORINTUMESCENT SEALANT
SPRAYACRYLIC
SPRAYACRYLICCOLLAR
FIRESTOP SYSTEMS
8/11/2019 StonCor AD Firebarrier
3/23
FIREBARRIER
Silicone & Silicone SL
Forms a durable, flexible,water-tight bond
May be applied over a widetemperature range, -18C
to 50C (0F to 120F) Physical properties will
remain stable over time Will not crack or crumble Tools easily SL = self-levels - no
tooling required Neutral cure - low odour Underside of floor
applications tested Colours
Silicone: Red or GreySilicone SL: Red
PlumbingPipes, insulated pipes,glass, copper, steel, ironand combustible (plastic)pipes
ElectricalConduits, cables, cabletrays, bundled cables
DuctsSteel ducts
Joint SystemsHorizontal and vertical(horizontal only for SL)
Joints - Movement Capable
UL 2079 tested
Cartridges10.3 fl.oz. (304 mL)28.7 fl.oz. (850 mL)
Containers2.64 US gal (10 L) pails4.5 US gal (17 L) pails
Foil pack20 fl oz (600 mL)
ULI, ULC, cUL, ITS (WH), FM
IntumescentSealant
Water based, intumescent Economical Forms a durable,
water-tight bond
Physical properties remainstable over time
During a fire expands tofill opening wherecombustible piping waslocated
Tools easily Low odour Ideal for caulk and walk
systems
Colour: Red
PlumbingCopper, steel, ironinsulated, and combustible(plastic) pipes
DuctsSteel ducts
ElectricalCables, cable trays,bundled cables andelectrical conduits
Cartridges10.1 fl.oz. (300 mL)28.7 fl.oz. (850 mL)
Containers5 US gal (18.9 L) pails
Foil Pack20.3 fl.oz. (600 mL)
ULI, cUL
Acrylic Sealant
Water based Economical Forms a durable, flexible
water-tight bond
Applied by caulking ortrowel
Physical properties remainstable over time
Colour: Red
PlumbingPipes, insulated pipes,copper, steel, andcombustible (plastic) pipes
ElectricalConduits, cables, cabletrays
Joint SystemsHorizontal and vertical
Joints - Movement CapableUL 2079 tested
Cartridges10.1 fl.oz. (300 mL)28.7 fl.oz. (850 mL)
Containers5 US gal (18.9 L) pails
Foil Pack20.3 fl.oz. (600 mL)
ULI, cUL
PRODUC
TS
FEATURES
USAGE
SIZES
LISTED/
CERTIFIED
FIRESTOP SYSTEMS
A/D FIREBARRIER Silicone, Silicone SL,Seal, Seal NS, Intumescent Caulk or Putty
A/D FIREBARRIER Seal, Seal NS,SprayMastic, Silicone or Silicone SL
A/D Fire Protection Systems
ofrece un sistema completo
de productos requeridos
para sellos corta fuego.
Todos son certificados por
laboratorios independientes
y probados para asegurar
clasificaciones de proteccin
contra fuego en
penetraciones y aberturas en
pisos y paredes con
clasificaciones contra fuego.
A/D FIREBARRIER son
productos listados por
Underwriter Laboratories,
Intertek Testing Services
(Warnock Hersey), y Factory
Mutual, y son certificados
bajo rigurosos programas de
inspecciones a la fbrica.
8/11/2019 StonCor AD Firebarrier
4/23
Seal & Seal NS
Water based Economical Forms a durable,
water-tight bond
Seal may be poured,pumped or sprayed
Underside of floorapplications tested
Physical properties remainstable over time
ColoursSeal: BlueSeal NS: White (may betinted in the field), and Red
PlumbingPipes, insulated pipes,glass, copper, steel, andCPVC
ElectricalConduits, cables, cabletrays
Joint SystemsHorizontal and vertical
Joints - Movement CapableUL 2079 tested
Cartridges(Seal NS only)10.3 fl.oz. (304 mL)28.7 fl.oz. (850 mL)
Containers(Seal & Seal NS)5 US gal (19 L) pails
ULI, ULC, cUL, ITS (WH), FM
SprayAcrylic
Water based elastomeric Economical Forms a durable, water
tight bond
Physical properties willremain stable over time
May be sprayed ortrowelled
Curtain wall / floor jointstested
Colour: Red
Joint SystemsHorizontal and vertical,curtain wall, head-of-wall,perimeter and floor to wall
Joints - Movement CapableUL 2079 tested
Containers5 US gal (18.9 L) pails
ULI, cUL
Mortar
Foamed cement Single component Easy to use Economical
Mixes easily with water toform a lightweightnon-slumping paste that iseasy to place and tool
Self-supporting Tested for very large
openings Non-combustible
Colour: Grey
PlumbingGlass, copper, steel, iron,insulated pipes and multi-ple penetrations
ElectricalConduits, cables, cabletrays, multiple penetrations
DuctsSteel ducts
Large openings
Containers15.5 lb (7 kg) bags
ULI, ULC, cUL, ITS (WH), FM
Mineral Wool
Non-combustible Pre-cut strips facilitate
easy installation andprovide a smooth surface
to help control depth ofsealant that is applied
High quality, proprietaryinsulation blankets/strips
UL and ULC listed andcertified
GeneralA/D FIREBARRIER MineralWool is the recommendedand/or required backing forA/D FIREBARRIER sealantsin most firestopapplications
Packaged 25 lb (11 kg)nominal in plastic bags invarious pre-cut x 4 ft stripsor blankets
ULI, ULC, ITS (WH), FM
A/D FIREBARRIER Intumescent Sealant
A/D FIREBARRIER Acrylic Sealant
A/D FIREBARRIER Silicone & Silicone SL
A/D FIREBARRIER SprayAcrylic
A/D FIREBARRIER Seal & Seal NS
A/D FIREBARRIER Mineral Wool
8/11/2019 StonCor AD Firebarrier
5/23
Pillows
Quick and clean singleproduct installation
No mesh or lath required No sealant or putty
required Ideal for cable retrofitting Easy to install, remove or
replace
ElectricalCables, cable trays,bundled cables
GeneralBlank or temporaryopenings
2 x 4 x 8 i n .(50 x 100 x 200 mm)packaged 25 per box
ULI, ULC, cUL
Collars, Wrap Strip &Collar Strips
Easy to install withcommon tools
Collars - Convenient, readyto install 3, 4 and 6-in.
nominal trade sizes Wrap Strip - For use with
or without steel Collar Strip Intumescent feature closes
off and seals plastic pipesand pipe insulation
Passes 50 Pa testrequirement in Canada(refer to test designs)
PlumbingCombustible (plastic) pipesand insulated pipesthrough concrete orgypsum wallboard, verticaland horizontal
CollarsNominal 3, 4 and6 in. trade sizes
Wrap Strip1 or 2 in. wide x 1/4 in.thick x 12 ft strips
Collar Strip50 ft coil
ULI, ULC, cUL
Putty
Easy to install Single component Intumescent No mixing
Remains soft and pliable
PlumbingPipes through concretewalls and floors
ElectricalCables and conduitsthrough gypsum wallboard.
Sticks66.2 in3 (1085 mL)packaged 12 per carton
ULI, cUL
Putty Pads & Inserts
Used to maintain hourlyfire resistance ratings offire resistive walls andpartitions containing
electrical boxes Permit greater density of
outlet and switch boxes inrated walls than wouldotherwise be permitted bycodes for unprotectedboxes
Intumescent materialsexpand when exposed tofire to seal off the box
Single component Easy to install
ElectricalProtect electrical outlet andswitch boxes
Inserts2 x 4 in. or 4 x 4 in.packaged 50 per carton
Putty Pads6 x 7 x .2 in. &9.25 x 9.25 x .2 in.packaged 12 per carton
ULI, cUL
A/D FIREBARRIER Mortar
A/D FIREBARRIER Pillows
A/D FIREBARRIER Putty Pads & Inserts
A/D FIREBARRIER Putty
A/D FIREBARRIER Collars
A/D FIREBARRIER Wrap Strip & Collar Strips
8/11/2019 StonCor AD Firebarrier
6/23
FIREBARRIERINTUMESCENT SEALANT
1. PRODUCT NAMEA/D FIREBARRIER IntumescentSealant.
2. PRODUCT DESCRIPTION
Basic Use:
A/D FIREBARRIERIntumescent Sealant is a single
component intumescent acrylicwater based sealant intended foruse as a firestop systemcomponent.
Composition and Materials:A/D FIREBARRIER IntumescentSealant forms a durable, flexible,watertight bond with mostconstruction materials. It is appliedindependently for caulk and walksystems or over mineral wool or
backer rod (refer to test designdetails) to seal the openings wherebuilding services such as pipes andcables penetrate fire ratedassemblies. May be applied bycaulking gun or trowel. Clean up iswith water.
A/D FIREBARRIER IntumescentSealant contains water and is best ifprotected from freezing.
Packaging : See table 2. Refer tothe A/D FIREBARRIER estimatingguide for complete volume and
coverage information.
Color:Red
Appl ication Limi tat ions:
A/D FIREBARRIER IntumescentSealant is intended for use atinterior locations in buildings only.Protect from direct contact withwater until cured. Curing time willvary with temperature and humidity.
Do not use where abrasion orphysical abuse is anticipated.
Installation in confined or air-free
spaces may inhibit cure.
Do not apply to surfaces withspecial protective or cosmeticcoatings without prior consul-tation with the manufacturer andfirst testing adhesion.
A/D FIREBARRIER IntumescentSealant has been tested innumerous firestop configurations.For optimum economy andperformance, apply to athickness equal to or slightlygreater than the minimum test
design thickness. Excessivedepth to width ratios may causesealant failure DO NOT applyexcessive thickness. As aguideline, A/D Fire ProtectionSystems recommends theminimum tested system thick-nesses not be exceeded by morethan 25%.
3. TECHNICAL DATA
Physical Properties:Refer to Table 1.
Standards: A/D FIREBARRIERIntumescent Sealant has beentested in accordance with thefollowing: ANSI/UL1479, ASTME814 and CAN4/ULC-S115M.Systems certified for use in Canadaare available under the cUL mark.
FGG/BM/CZ System Compatible
indicates that this product has beentested, and is monitored on an
ongoing basis, to assure itschemical compatibility with
FlowGuard Gold, BlazeMaster
and Corzan pipe and fittings.
FGG/BM/CZ, FlowGuard Gold,
BlazeMaster, and Corzan are
licensed trademarks of the LubrizolCorporation.
Contact A/D Fire ProtectionSystems for a current list of firerated systems.
4. INSTALLATIONClean all openings to be firestoppedby removal of foreign matter andcontaminants such as oil, dust,grease, frost, water, surface dirt, oldsealants glazing compound,protective coatings, etc. Refer to firetest design / system.
Priming: A/D FIREBARRIERIntumescent Sealant does not
require any priming. In view of theunpredictability of surfacecharacteristics, it is recommendedthat a test sample of sealant beapplied on the surface to testadhesion.
Masking: Areas adjacent toopenings to be firestopped can bemasked to assure a neatappearance. The masking tapeshould not be allowed to touch theclean surfaces to which the caulk isto adhere. Remove masking tape
immediately.
Appl ications: For caulk and walksystems, simply apply the productwhere required and let cure.Where backer material (mineralwool, backer rod, etc.) is required byfire test design or system, installbacker material as specified.Surfaces of backer material toreceive caulk should be recessed inthe opening to a depth equal to therequired thickness of sealant.
Table 1
PHYSICAL PROPERTIES*
Properties ResultsColor RedOdor MildpH 7.0 - 10.0VOC (grams/liter) 0Flame Spread (ASTM E-84) 0Smoke Developed (ASTM E-84) 0Cure Time (ASTM C-679) 3 - 5 daysSkin over Time OvernightShore A Hardness (ASTM C-661) 15 - 20
Application Temperature 40 - 110F (5 - 43C)Freeze Sensitive YesPaintable Yes
*Values given are not intended for specification preparation.
8/11/2019 StonCor AD Firebarrier
7/23
Where mineral wool is requiredbacker material, we recommend theuse of A/D FIREBARRIER MineralWool this high quality material is
available pre-cut for easy installationand allows a controlled depth ofcaulk to be applied for maximumeconomy. Apply A/D FIREBARRIERIntumescent Sealant in a continuousoperation to fill and seal theopening. Tool the sealant to spreadit against the backer material andthe opening surfaces.Simply fill the annular space to therequired depth and form a smoothbead or crown at the surfaces.
Excess sealant should be cleanedwith water.CURED SEALANT IS USUALLYVERY DIFFICULT TO REMOVE
WITHOUT ALTERING ORDAMAGING THE SURFACE TOWHICH THE SEALANT HAS BEENMISAPPLIED.
Precaution: On direct contact,uncured sealant may irritate eyes.Flush with water and call aphysician. Avoid prolonged contactwith skin. Keep out of reach ofchildren.
To safely use this product, read andabide by Material Safety Data Sheet(MSDS).
Shelf Life: A/D FIREBARRIERIntumescent Sealant has shelf life ofone year from the date ofmanufacture when stored in originaland unopened container at or below
110F (43C) and above 40F (5C).See top of box or label on pail fordate of manufacture (day/ month/year).
5. AVAILABILITY AND COSTAvailabi li ty: A/D sales offices andtechnical representatives arelocated throughout North America.(See below)
6. MAINTENANCENo maintenance should be required.If intumescent sealant becomesdamaged, replace damaged portion.Clean surfaces in damaged areas,and repair with fresh A/DFIREBARRIER IntumescentSealant.
7. TECHNICAL SERVICESContact nearest A/D representative.
March 10, 2008
Table 2
Type ofPackaging
Size VolumeCoverage at deep x
1 wide
10.1 fl. oz.(300 mL)
18.2 in3
(300 cm3)
6.1 lineal ft.(1.86 lineal m)
Cartridges28.7 fl. oz.
(850 mL)
51.8 in3
(850 cm
3
)
17.3 lineal ft.
(5.27 lineal m)
Foil packs20 fl. oz.(600 mL)
36 in3
(600 cm3)
12.2 lineal ft.(3.72 lineal m)
Pails5 gal
(18.9 L)1155 in
3
(18900 cm3)
384.4 lineal ft.(117.18 lineal m)
8/11/2019 StonCor AD Firebarrier
8/23
FIREBARRIERINTUMESCENT CAULK
1. PRODUCT NAME
A/D FIREBARRIER IntumescentCaulk.
2. PRODUCT DESCRIPTION
Basic Use: A/D FIREBARRIERIntumescent Caulk is a waterbased, single componentelastomeric sealant intended foruse as a firestop systemcomponent.
Composition and Materials:A/D FIREBARRIER IntumescentCaulk forms a durable, flexible,watertight bond with mostconstruction materials. It is appliedindependently for caulk and walk
systems or over mineral wool orbacker rod (refer to test designdetails) to seal the openings wherebuilding services such as pipes andcables penetrate fire ratedassemblies. May be applied bycaulking gun or trowel. Clean up iswith water.
A/D FIREBARRIER IntumescentCaulk contains water and is best ifprotected from freezing. If frozen,thaw completely before usePackaging: A/D FIREBARRIERIntumescent Caulk is available in10.3 fl. oz (304 ml) cartridges, 20 fl.oz (600 ml) foil packs and nominal4.5 gal (17 L) plastic pails. Contentsare 18.6 in
3, 36.1 in
3 and 1050 in
3
respectively. Refer to the A/DFIREBARRIER estimate guide forvolume and coverage information.
Color:Red
Application Limitations:
A/D FIREBARRIER IntumescentCaulk is intended for use at interiorlocations in buildings only. Protect
from direct contact with water untilcured. Curing time will vary withtemperature and humidity.
Do not use where abrasion orphysical abuse is anticipated.
Installation in confined or air-freespaces may inhibit cure.
Do not apply to surfaces withspecial protective or cosmeticcoatings without prior consul-tation with the manufacturer andfirst testing adhesion.
A/D FIREBARRIER IntumescentCaulk has been tested innumerous firestop configurations.For optimum economy andperformance, apply to athickness equal to or slightlygreater than the minimum test
design thickness. Excessivedepth to width ratios may causesealant failure DO NOT applyexcessive thickness. As aguideline, A/D Fire ProtectionSystems recommends theminimum tested system thick-nesses not be exceeded by morethan 25%.
3. TECHNICAL DATA
Physical Properties:Refer to Table 1.
Fire Resistance Ratings: A/DFIREBARRIER Intumescent Caulkhas been tested and certified by ULIand ULC in accordance with ULC-S115, ASTM E814 and
ANSI/UL1479. The following testedfirestop systems were published atthe time of this writing:
ULI System Nos:C-AJ-1343,-1344, -1345, -1365, -1492,-1493, -2464, -5260, -7042
WL-1225, 1235, 1236
F-C-1086, -2195, -2206, -3061and -5051.
ULC Systems Nos:SP961,
-962, -964, -965, -966, -967,
-968, -969, -984, -989, -1001,
-1002, -1003, -1076, -1077,
-1078 and 1079, SPC53, -58,-98, -99 and -100.
Contact A/D Fire ProtectionSystems for a current list of firerated systems.
4. INSTALLATION
Clean all openings to be firestoppedby removal of foreign matter andcontaminants such as oil, dust,grease, frost, water, surface dirt, oldsealants glazing compound,protective coatings, etc. Refer to fire
test design / system.
Priming: A/D FIREBARRIERIntumescent Caulk does not requireany priming. In view of theunpredictability of surfacecharacteristics, it is recommendedthat a test sample of sealant beapplied on the surface to testadhesion.
Masking: Areas adjacent toopenings to be firestopped can bemasked to assure a neat
PHYSICAL PROPERTIES*
Properties ResultsColor RedOdor Mild
UncuredFlow rate (ASTM C920) 175 mL/minVolatile by Volume 35.7%Tack Free Time 30 min. (@ 70F (21C) 50% RH)Specific Gravity 1.25VOC (ASTM D 3960-92) 0.14 lb/gal US (16 g/L)
Cured
Flow, Sag or Slump 0Hardness (A) (ASTM D2240) 35-40Elongation at Break (ASTM D412) 85%Tensile Strength (ASTM D412) 145 psiEffects of Accelerated WeatheringUV Exposure (ASTM C920) No CrackingCold Temperature (ASTM C920) No Cracking
*Values given are not intended for specification preparation.
8/11/2019 StonCor AD Firebarrier
9/23
May 2004
appearance. The masking tapeshould not be allowed to touch theclean surfaces to which the caulk isto adhere. Remove masking tapeimmediately.
Applications: For caulk and walksystems, simply apply the productwhere required and let cure.
Where backer material (mineralwool, backer rod, etc.) is required byfire test design or system, installbacker material as specified.Surfaces of backer material toreceive caulk should be recessed inthe opening to a depth equal to therequired thickness of sealant.Where mineral wool is requiredbacker material, we recommend theuse of A/D FIREBARRIER MineralWool this high quality material isavailable pre-cut for easy installationand allows a controlled depth of
caulk to be applied for maximumeconomy. Apply A/D FIREBARRIERIntumescent Caulk in a continuousoperation to fill and seal theopening. Tool the caulk to spread it
against the backer material and theopening surfaces.Simply fill the annular space to therequired depth and form a smoothbead or crown at the surfaces.
Excess sealant should be cleanedwith water.CURED SEALANT IS USUALLYVERY DIFFICULT TO REMOVEWITHOUT ALTERING ORDAMAGING THE SURFACE TOWHICH THE SEALANT HAS BEENMISAPPLIED.
Precaution: A/D FIREBARRIERIntumescent Caulk is a water-basedproduct. No acetic acid orobjectionable byproducts areevolved during application. Ondirect contact, uncured caulk mayirritate eyes. Flush with water andcall a physician. Avoid prolongedcontact with skin. Keep out ofreach of children.
To safely use this product, read andabide by Material Safety Data Sheet(MSDS).
Shelf Life: A/D FIREBARRIERIntumescent Caulk has shelf life ofone year from the date ofmanufacture when stored in originaland unopened container at or below
90F (32C) and above 32F (0C).See top of box or label on pail fordate of manufacture (day/ month/year).
5. AVAILABILITY AND COST
Availability: A/D sales offices andtechnical representatives arelocated throughout North America.(See below)
6. MAINTENANCE
No maintenance should be required.If intumescent caulk becomesdamaged, replace damaged portion.Clean surfaces in damaged areas,and repair with fresh A/D
FIREBARRIER Intumescent Caulk.7. TECHNICAL SERVICES
Contact nearest A/D representative.
8/11/2019 StonCor AD Firebarrier
10/23
FIREBARRIER ACRYLIC SEALANT
1. PRODUCT NAMEA/D FIREBARRIER Acrylic Sealant
2. PRODUCT DESCRIPTIONA/D FIREBARRIER Acrylic Sealant
is a single component, water-basedacrylic sealant intended for use as afirestop system component.
Basic Use: A/D FIREBARRIERAcrylic Sealant is designed foreconomical use in joint and servicepenetration firestop configurations.It forms a durable, flexible,watertight bond with mostconstruction materials. In mostcases, no primer is required. Maybe applied by caulking gun ortrowel. Physical properties will
remain stable over time.Composition and Materials:
A/D FIREBARRIER Acrylic Sealantis designed to tool easily. It is waterbased and must be protected fromfreezing and from water until fullycured. Store and install attemperatures above 40F (5C).
Color:Red
Packaging: See table 2. Refer tothe A/D FIREBARRIER estimatingguide for complete volume andcoverage information.
Application Limitations:
Do not install when ambienttemperature or temperature ofsubstrate is below 40F (5C).
Protect from freezing and wateruntil sealant is fully cured.
Do not install to surfaces withspecial protective or cosmeticcoatings without prior consul-tation with manufacturer andfirst testing adhesion.
Do not install where abrasion orphysical abuse is anticipated.
For best economy andperformance the product shouldbe applied to a thickness equalto or slightly greater than theminimum test design thickness.
Excessive depth to width ratiosmay cause sealant failure donot apply excessive thick-ness. As a guideline, werecommend that the minimumtest system thicknesses not beexceeded by more than 25%.
Standards: A/D FIREBARRIERAcrylic Sealant has been tested inaccordance with the following:
ANSI/UL1479, ANSI/UL 2079,ASTM E814 and CAN/ULC-S115M.
3. TECHNICAL DATAA/D FIREBARRIER Acrylic Sealantis listed by ULI. For details of ratedfirestop systems see ULI s FireResistance Directory, Volume 2.Systems certified for use in Canadaare available under the cUL mark.
4. INSTALLATIONClean all openings to be firestoppedby removal of foreign matter andcontaminants such as oil, dust,grease, frost, water, surface dirt, oldsealants, glazing compounds,protective coatings etc. Cleaning ofall surfaces should be done on thesame day in which the sealant isapplied.
Priming: A/D FIREBARRIERAcrylic Sealant does not require
priming. In view of theunpredictability of surfacecharacteristics, it is recommendedthat a test sample of sealant beapplied on the surface to testadhesion.
Masking: Areas adjacent toopenings to be firestopped can be
masked to assure a neatappearance. The masking tapeshould not be allowed to touch theclean surface to which the sealant is
to adhere. Remove masking tapeimmediately.Install backup materials asspecified. Excess sealant should bewiped from glass, metal and plasticsurfaces while uncured. Clean up iswith water.CURED SEALANT IS USUALLYVERY DIFFICULT TO REMOVEWITHOUT ALTERING OR DAM-
AGING THE SURFACE TO WHICHTHE SEALANT HAS BEEN
APPLIED.Precaution: May cause irritation.May be harmful if swallowed. Avoidgetting in eyes. Wash handsthoroughly after handling. Use onlyas directed.Keep out of reach of children.To safely use this product, read andabide by Material Safety Data Sheet(MSDS).
Shelf Life:When stored at or below110F (43C) and above 40F (5C),
A/D FIREBARRIER Acrylic Sealant
has a shelf life of one year fromdate of manufacture.Note:Protect from freezing.
Table 1 PHYSICAL PROPERTIES*
Color Red
pH 7.0 - 9.0VOC (grams/liter): 65
Flame Spread (ASTM E84) 15
Smoke Developed (ASTM E84) 0
Cure Time 3 - 5 days
Skin over Time Overnight
Movement Capability: (UL 2079; class I, II, III) + 25 %, maximum
Shore A Hardness (ASTM C-661) 15 - 20
Application Temperature 40 - 110F (5 - 43C)
Freeze Sensitive Yes
Paintable Yes
*Values given above are not intended for specification preparation.
8/11/2019 StonCor AD Firebarrier
11/23
5. AVAILABILITY AND COSTAvailability: A/D sales offices andtechnical representatives arelocated throughout North America.(See below)
6. MAINTENANCE
No maintenance should be required.If sealant becomes damaged,replace damaged portion. Cleansurfaces in damaged area andrepair with fresh A/D FIREBARRIER
Acrylic Sealant. Damage by othertrades should be patched at theexpense of trade causing damage.
7. TECHNICAL SERVICESContact nearest A/D office.
June 25, 2007
Table 2
Type ofPackaging
Size VolumeCoverage at deep x
1 wide
10.1 fl. oz.(300 mL)
18.2 in3
(300 cm3)
6.1 lineal ft.(1.86 lineal m)
Cartridges28.7 fl. oz.
(850 mL)
51.8 in3
(850 cm3)
17.3 lineal ft.
(5.27 lineal m)
Foil packs20 fl. oz.(600 mL)
36 in3
(600 cm3)
12.2 lineal ft.(3.72 lineal m)
Pails5 gal
(18.9 L)1155 in
3
(18900 cm3)
384.4 lineal ft.(117.18 lineal m)
8/11/2019 StonCor AD Firebarrier
12/23
FIREBARRIER SILICONE1. PRODUCT NAME
A/D FIREBARRIER Silicone
2. PRODUCT DESCRIPTIONA primerless single component
silicone sealant. The sealantcures to a durable, flexible,silicone rubber when exposed toatmospheric moisture.
Basic Use: A/D FIREBARRIERSilicone is designed foreconomical use in joint andservice penetration firestopconfigurations. It forms a durable,flexible, watertight bond with mostconstruction materials. In mostcases, no primer is required.
Composition and Materials:A/D FIREBARRIER Silicone isdesigned to tool easily. Its'physical properties will remainstable over time. It may beapplied over a wide temperaturerange, 0F to 120F (-18C to50C), allowing the sealant to beapplied in any season.
Packaging: A/D FIREBARRIERSilicone is available in nominal10.3 fl. oz. (304 mL) and 28.7 fl.oz. (850 mL) cartridges, 20 fl. oz
(600 mL) foil packs and 2.64 USgallon (10L) and 4.5 US gallon(17L) bulk containers. Contentsare 18.6 in
3, 49 in
3, 36.1 in
3, 634
in3 and 1050 in
3 respectively.
Refer to the A/D FIREBARRIERestimate guide for volume andcoverage information.
Color:Red or Grey*(*Note: requires special order)
Appl ication Limi tat ions:
Do not use where abrasion or
physical abuse is anticipated. Installation in confined or air-
free spaces may inhibit cure.
Silicones may be painted, butmovement of the silicone maycause the paint film to crackand peel. We recommend thesealant be applied afterpainting is completed.
Do not apply to surfaces thatwill be in direct contact withfood.
Do not apply to surfaces withspecial protective or cosmeticcoatings without prior consul-tation of the manufacturerand first testing adhesion.
For optimum economy andperformance the productshould be applied to a
thickness equal to or slightlygreater than the minimum testdesign thickness.
Excessive depth to widthratios may cause sealantfailure Do not applyexcessive thickness. As aguideline, A/D Fire ProtectionSystems recommends thatthe minimum test systemthicknesses not be exceededby more than 25%.
Standards:A/D FIREBARRIER
Silicone has been tested inaccordance with the following:ULC-S115, Standard Method ofFire Tests of Firestop Systems.
ASTM E814-83, StandardMethod of Fire Tests of Through-Penetration Fire Stops
ANSI/ULC 2079, Tests for FireResistance of Building JointSystems.
FGG/BM/CZ System
Compatible indicates that this
product has been tested, and ismonitored on an ongoing basis, toassure its chemical compatibility
with FlowGuard Gold,
BlazeMasterand Corzanpipe
and fittings. FGG/BM/CZ,
FlowGuard Gold,
BlazeMaster, and Corzanarelicensed trademarks of theLubrizol Corporation.
3. TECHNICAL DATAA/D FIREBARRIER Siliconesealant remains flexibleindefinitely between temperaturesof -50F and 300F (-45 and149C). It will not crack orcrumble.
A/D FIREBARRIER Siliconeconforms to the requirements of
ASTM C 920 for Elastomeric jointsealants, Type S, Grade NS,class 25, use NT, G, A and M.
A/D FIREBARRIER Silicone islisted by ULC, ULI, ITS (WarnockHersey) and Factory Mutual.For details of rated firestopsystems see ULCs List ofEquipment and Materials, Fire-stop System and Components,ULIs Fire Resistance Directory,Volume 2, ITS' s Listings Book
PHYSICAL PROPERTIES
Properties Results
UncuredTool/Work Time 5 minutesSkin Over Time @ 25C (77F) Less than 60 minutes @ 50% RHCuring Time @ 25C (77F) 48 hours @ 50% RHFlow, Sag or Slump NilSpecific Gravity 1.13Maximum strength After 21 daysVOC (ASTM D 3960-92) Less than 0.69 lb/gal US
Cured 7 days @ 25C (77F) 50% RH.Hardness (A) (ASTM D2240) 12Tear Strength (ASTM D624, Die B) 3.5 kN/m (20 ppi)Elongation at Break (ASTM D412) 600%
Shrink Factor NegligibleASTM C 920 Type S, NS, 25, NT, G, A & M
*Values given above are not intended to be used in specification preparation.
8/11/2019 StonCor AD Firebarrier
13/23
August 2008
and Factory Mutual s ApprovalGuide.
4. INSTALLATIONClean all openings to befirestopped by removal of foreignmatter and contaminants such asoil, dust, grease, frost, water,surface dirt, old sealants glazingcompound, protective coatings,
etc.
Priming: A/D FIREBARRIERSilicone generally does notrequire priming. In view of theunpredictability of surfacecharacteristics, it is recommendedthat a test sample of sealant beapplied on the surface to testadhesion.
Masking: Areas adjacent toopenings to be firestopped can bemasked to assure a neat
appearance. The masking tapeshould not be allowed to touchthe clean surfaces to which thesilicone is to adhere. Removemasking tape immediately.
A/D FIREBARRIER Mineral Woolis the required backup material inmost systems. The materialallows a controlled depth ofsealant to be applied formaximum economy.
Install backup material asspecified. Surfaces of mineralwool to receive sealant should berecessed in the opening to adepth equal to the required thick-ness of sealant. Apply A/DFIREBARRIER Silicone in acontinuous operation to fill andseal the opening. Tool thesealant to spread it against thebackup material and the openingsurfaces.
Individual penetrations throughdrywall may not require a backingmaterial for the silicone. Simplyfill the annular space to therequired depth and form a smoothbead or crown at the surfaces.
Excess sealant should be dry-wiped from glass, metal andplastic surfaces while stilluncured, followed with acommercial solvent such as xylol,toluol, or methyl ethyl ketone.
CURED SEALANT IS USUALLYVERY DIFFICULT TO REMOVEWITHOUT ALTERING ORDAMAGING THE SURFACE TOWHICH THE SEALANT HASBEEN MISAPPLIED.
Precaution: On direct contact,uncured sealant may irritate eyes.Flush with water and call a
physician. Avoid prolongedcontact with skin. Keep out ofreach of children.To safely use this product, readand abide by Material Safety DataSheet (MSDS). Provide adequateventilaion.
Shelf Life: When stored inoriginal and unopened container
at or below 32C (90F), A/DFIREBARRIER Silicone has ashelf life of one year from date ofmanufacture.
5. AVAILABILITY AND COSTAvailabi li ty: A/D sales officesand technical representatives arelocated throughout North
America. (See below)
6. MAINTENANCENo maintenance should berequired. If silicone sealantbecomes damaged, replace dam-aged portion. Clean surfaces indamaged areas, and repair withfresh A/D FIREBARRIERSilicone.
7. TECHNICAL SERVICESContact nearest A/Drepresentative.
8/11/2019 StonCor AD Firebarrier
14/23
FIREBARRIER SILICONE SL1. PRODUCT NAME
A/D FIREBARRIER Silicone SL
2. PRODUCT DESCRIPTIONBasic Use: A primerless single
component self-leveling siliconesealant. It cures to a durable,flexible, silicone rubber whenexposed to atmospheric moisture. Itis designed for economical use in
joint and service penetration firestopconfigurations. It forms a durable,flexible, watertight bond with mostconstruction materials. In mostcases, no primer is required.
Composition and Materials:A/D FIREBARRIER Silicone SL isdesigned to self-level. No tooling is
required. Physical properties willremain stable over time. It may beapplied over a wide temperaturerange, 0F to 120F (-18C to 50C),allowing the sealant to be applied inany season.
Packaging: A/D FIREBARRIERSilicone SL is available in nominal10.3 fl. oz. (304 mL) and 28.7 fl. oz.(850 mL) cartridges, 20 fl. oz (600mL) foil packs and 2.64 US gallon(10L) and 4.5 US gallon (17L) bulkcontainers. Contents are 18.6 in
3, 49
in3, 36.1 in3, 634 in3 and 1050 in3respectively. Refer to the A/DFIREBARRIER estimate guide forvolume and coverage information.
Color:Red
Appl ication Limitat ions:
Do not use where abrasion orphysical abuse is anticipated.
Installation in confined or air-freespaces may inhibit cure.
Silicones may be painted, but
movement of the silicone maycause the paint film to crack andpeel. We recommend thesealant be applied after paintingis completed.
A/D FIREBARRIER Silicone SLis self-leveling and is thereforelimited to horizontal applications.
Do not apply to surfaces withspecial protective or cosmeticcoatings without prior consul-tation of the manufacturer andfirst testing adhesion.
Do not apply to surfaces that willbe in direct contact with food.
For optimum economy andperformance the product shouldbe applied to a thickness equalto or slightly greater than theminimum test design thickness.
Excessive depth to width ratiosmay cause sealant failure. Donot apply excessive thick-ness. As a guideline, A/D FireProtection Systems recom-mends the minimum testedsystem thicknesses not beexceeded by more than 25%.
Standards: A/D FIREBARRIERSilicone SL has been tested inaccordance with the following:ULC-S115, Standard Method ofFire Tests of Firestop Systems.
ASTM E814-83, Standard Methodof Fire Tests of Through-PenetrationFire Stops.
ANSI/UL 2079, Tests for FireResistance of Building JointSystems.
FGG/BM/CZ System Compatible
indicates that this product has beentested, and is monitored on anongoing basis, to assure itschemical compatibility with
FlowGuard Gold, BlazeMaster
and Corzan pipe and fittings.
FGG/BM/CZ, FlowGuard Gold,
BlazeMaster, and Corzan are
licensed trademarks of the LubrizolCorporation.
3. TECHNICAL DATAA/D FIREBARRIER Silicone SL
sealant remains flexible indefinitelybetween temperatures of -50F and300F (-45C to 149C). It will notcrack or crumble.
A/D FIREBARRIER Silicone SL islisted by ULC, ULI, ITS and FM. Fordetails of rated firestop systems seeULIs Fire Resistance Directory,Volume 2, ULCs List of Equipmentand Materials, Firestop Systems andComponents, ITS's Listings Bookand FMs Approval Guide.
Contact A/D Fire Protection Systemsfor a current list of tested systems.
4. INSTALLATIONClean all openings to be firestoppedby removal of foreign matter andcontaminants such as oil, dust,grease, frost, water, surface dirt, oldsealants, glazing compound,protective coatings, etc.
Priming: A/D FIREBARRIERSilicone SL generally does notrequire priming. In view of the
PHYSICAL PROPERTIES
Properties Results
UncuredColor RedSkin Over Time @ 25C (77F) 75 minutesCuring Time @ 25C (77F) 48 hoursFlow, Sag or Slump Self-levelingSpecific Gravity 1.15VOC (ASTM D 3960-92) < 0.50 lb/gal US (59.9 g/L)
Cured(21 days @ 25C (77F) 50% RH)Color RedHardness (A) (ASTM D2240) 5Elongation at Break (ASTM D412) 600%Movement Capability (ASTM C719) +100/-50 %
Tensile strength (ASTM D412) 98.5 kg/cm2
(140 psi)Adhesion in peel (ASTM C794) 15.7 lbs. (180 , 2 in. per min.,
mortar, cohesive failure)
*Values given above are not intended for specification preparation.
8/11/2019 StonCor AD Firebarrier
15/23
August 2008
unpredictability of surface charac-teristics, it is recommended that atest sample of sealant be applied onthe surface to test adhesion.
Masking: Areas adjacent toopenings to be firestopped can bemasked to assure a neatappearance. The masking tape
should not be allowed to touch theclean surfaces to which the siliconeis to adhere. Remove masking tapeimmediately.
A/D FIREBARRIER Mineral Wool isthe required backer material in mosttested systems. The material allowsa controlled depth of sealant to beapplied for maximum economy.
Install backer material as specified.Surfaces of mineral wool to receivesealant should be recessed in theopening to a depth equal to the
required thickness of sealant. ApplyA/D FIREBARRIER Silicone SL in
sufficient quantity to fill and seal theopening to the specified depth. It isself-leveling and therefore no toolingis required.
Excess sealant should be dry-wipedfrom glass, metal and plasticsurfaces while still uncured, followedwith a commercial solvent such asxylol, toluol, or methyl ethyl ketone.
Cured sealant may be very difficultto remove without altering ordamaging the surface to which thesealant has been misapplied.
Precaution: On direct contact,uncured sealant may irritate eyes.Flush with water and call aphysician. Avoid prolonged contactwith skin. Keep out of reach ofchildren.To safely use this product, read andabide by Material Safety Data Sheet
(MSDS). Provide adequateventilation
Shelf Life: When stored in originaland unopened container at or below90F (32C), A/D FIREBARRIERSilicone SL has a shelf life of oneyear from date of manufacture.
5. AVAILABILITY AND COSTAvailabi li ty: A/D sales offices andtechnical representatives are located
throughout North America. (Seebelow)
6. MAINTENANCENo maintenance should be required.If silicone sealant becomesdamaged, replace damaged portion.Clean surfaces in damaged areas,and repair with fresh A/DFIREBARRIER Silicone SL.
7. TECHNICAL SERVICESContact nearest A/D representative.
8/11/2019 StonCor AD Firebarrier
16/23
FIREBARRIER SPRAYACRYLIC1. PRODUCT NAME
A/D FIREBARRIER SprayAcrylic
2. PRODUCT DESCRIPTIONA/D FIREBARRIER SprayAcrylic isa single component, water-basedelastomeric that cures to a durable,
flexible, fire resistant seal.Basic Use: A/D FIREBARRIERSprayAcrylic is designed for use asa firestop sealant in joint firestopconfigurations including head-of-wall, curtain wall, perimeter andfloor to wall construction joints.
Composition and Materials:A/D FIREBARRIER SprayAcrylic iswater-based. It is designed for sprayand trowel application to vertical andhorizontal surfaces. It forms durable,flexible, watertight bonds with most
materials. Physical properties willremain stable over time. Productcontains mold growth inhibiters.
A/D FIREBARRIER SprayAcryliccontains water and is best ifprotected from freezing. If frozen,thaw completely before use. Store,transport and install at temperaturesabove 40F (5C).
Packaging: A/D FIREBARRIERSprayAcrylic is available in 5 USgallon (18.9 L) pails. Coverage perpail is approximately 67 ft
2 (6.3 m
2)
at 1/8-in. (3 mm) wet thickness.
Color:Red
Appl ication Limitat ions: Do not install when ambienttemperature or temperature ofsubstrate is below 40F (5C). Protect from freezing and water
until sealant is fully cured. Do not apply to surfaces with
special protective or cosmeticcoatings without first testingadhesion and prior consultationwith manufacturer.
Not intended for immersion orcontinuous exposure to water.
Do not install on hot surfacesabove 200F (90C).
A/D FIREBARRIER SprayAcrylichas been tested in numerousfirestop joint firestop systems.For optimum economy andperformance, the product shouldbe applied to a thickness equal toor slightly greater than the
required minimum test designthickness. Excessive depth towidth ratios may cause sealant
failure do not apply excessivethickness. As a guideline, werecommend that the minimumtest system thicknesses not beexceeded by more than 25%.
3. TECHNICAL DATAStandards: A/D FIREBARRIERSprayAcrylic has been tested and inaccordance with the following:
ANSI/UL1479, ANSI/UL2079, ASTME814 and CAN4/ULC-S115M.For details of rated firestop systemssee UL s Fire Resistance Directory,Volume 2. Systems certified for usein Canada are available under thecUL mark.
Surface Burning Characteristics:(ASTM E84 )Flame Spread: 15Smoke Developed: 0
4. INSTALLATIONNo dilution or mixing is required foruse. Clean all openings to befirestopped by removal of foreignmatter and contaminants such as
oil, dust, grease, frost, water,surface dirt, old sealants, glazingcompounds, protective coatings,etc.
Priming: Generally, a primer willnot be required. It is recommendedthat a test sample of sealant beapplied on the surface to testadhesion.
Masking: Surfaces adjacent toopenings to be firestopped can bemasked to assure a neat
appearance. The masking tapeshould not be allowed to touch theclean surface to which the sealant is
to adhere. Remove masking tapeimmediately.
Forming/Backing: Install forming /backing material as specified by thetested firestop system. Unlessotherwise specified, A/D FIREBAR-RIER Mineral Wool is therecommended backup material.
Appl ication: A/D FIREBARRIERSprayAcrylic may be applied byspray or trowel to vertical andhorizontal surfaces.
Refer to tested firestop system forminimum wet film thickness that isrequired - usually 1/8 (3.2 mm).Use a wet film gauge to measurewet film thickness. Apply A/DFIREBARRIER SprayAcrylic so asto seal the mineral wool backer withthe required thickness and overlapadjacent surfaces a minimum of in. (13 mm) or as otherwisespecified in tested firestop system.Excess sealant should be wipedfrom glass, metal and plasticsurfaces while uncured. Clean upwith water. Follow equipmentmanufacturers instructions for cleanup and use. Protect adjacentsurfaces from overspray andunintended contact - Cured SealantMay Be Very Difficult To RemoveWithout Altering Or DamagingThe Surface To Which TheSealant Has Been Applied.
Table 1 PHYSICAL PROPERTIES*
Color Red
pH 7.0 - 9.0
VOC (grams/liter): 65
Flame Spread (ASTM E84) 15
Smoke Development (ASTM E84) 0
Cure Time 3 - 5 days
Skin over Time Overnight
Movement Capability: (UL 2079; class I, II, III) + 25 %, maximum
Shore A Hardness (ASTM C-661) 15 - 20
Application Temperature 40 - 110F (5 - 43C)
Freeze Sensitive Yes
Paintable Yes
*Values given above are not intended for specification preparation.
8/11/2019 StonCor AD Firebarrier
17/23
Precautions: May cause irritation.May be harmful if swallowed. Avoidcontact with eyes. Wash handsthoroughly after handling. Use onlyas directed. Keep out of reach of
children. To safely use this product,read and abide by Material SafetyData Sheet (MSDS).
Shelf Life: A/D FIREBARRIERSprayAcrylic has a shelf life of 1
year from the date of manufacturewhen stored in original andunopened container below 110F
(43C) and above 40F (5C).
5. MAINTENANCE
No maintenance should be required.If product becomes damaged, rep-
lace with new A/D FIREBARRIERSprayAcrylic. All surfaces should beclean and free of any material thatwould prevent adhesion.
6. AVAILABILITY AND COST
Availabi li ty:A/D sales offices andtechnical representatives arelocated throughout North America.(See below).
7. TECHNICAL SERVICES
Contact nearest A/D office orrepresentative
June 25, 2007
Table 2 Quick Reference Guide Spray Application of SprayAcrylic
Hoses 50 ft of 1/4 in. (I.D.) Blue Max
Whip line 6 ft - (I.D.) whip line with swivel
Tips419 - 423 heavy-duty self cleaning reversible type621 - 625 heavy-duty self cleaning reversible type
Spray machineAirless sprayer capable of 3300psi pressure and min.
delivery of 0.95 gpm without surging
Filters 60-80 mesh in gun & 60-80 in manifold
Mixing Heavy-duty drill with paddle for 30 seconds
Application Rate 1/8 in. (3 mm) wet
Finish Follows profile of backer material
Trowel May be toweled
Clean-up Water
8/11/2019 StonCor AD Firebarrier
18/23
FIREBARRIERMORTAR
1. PRODUCT NAMEA/D FIREBARRIER Mortar
2. PRODUCT DESCRIPTION
A non-combustible fiber reinforced,foamed cement mortar.
Basic Use: A/D FIREBARRIERMortar is intended to provide non-combustible and tight fittingfirestops at openings andpenetrations through fire-rated walland floor assemblies. A/DFIREBARRIER Mortar powdermixes easily with water to form amousse or shaving cream-like non-slumping paste. This featurepermits easy installation with a
minimum of damming. Whencured, A/D FIREBARRIER Mortaris self-supporting and thereforemay be used for large openingswhere other firestopping materialsare impractical.
Composition and Materials:A/D FIREBARRIER Mortar mixesand trowels easily. Tools arecleaned with water. A/DFIREBARRIER Mortar requires andcontains no solvents. It iscomprised of materials of low
toxicity. Dust protection is recom-mended see INSTALLATION.
Color: A distinctive charcoal (darkgrey).
Packaging: A/D FIREBARRIER
Mortar is packaged in 15.5 lb. (7kg) bags. A 275 mL measuring cupis provided in each bag of productfor convenience. One bag will yieldapproximately 850 in.
3 (13,930cm
3)
- approximately enough for a 1 x 2ft. (305 x 610 mm) opening at an
installed depth of 3 in. (75 mm).Note: Ignores volume occupied bypenetrating items. Yield calculationis based on product mixed inaccordance with our installationinstructions.
Application Limitations:Do not install when temperature isbelow 40F (5C). In horizontal applications, inter-mediate support may be required.Do not permit pedestrian or othertraffic.
Where A/D FIREBARRIER Mortarwill be subject to acidic exposure,like other Portland cement-basedproducts it may require a protectivecoating.
3. TECHNICAL DATAPhysical Properties: Refer toTable 1.Fire Resistance Ratings: A/DFIREBARRIER Mortar has beentested and certified by ULI, ULC,ITS and FM in accordance with
ANSI / UL 1479, ASTM E814 andULC-S115-95. For details of ratedfirestop systems see ULIs FireResistance Directory, Volume 2,ULCs List of Equipment andMaterials, Firestop Systems andComponents, ITS' s Listing Bookand Factory Mutual s ApprovalGuide. Current systems include:ULI:CAJ-1126, -1128, -1195, -1196, -2249, -5095, -7029, -7030, -8029 and WL-8005.ULC:SP196, -229, -230, -326, -341, -396, -422, -423, -424, -758, -765 and -767.
FM:91, 92, 94 and 205
ITS:AD/PHV 180-01, -02 and -03.
4. INSTALLATIONClean openings to be fire-stoppedby removal of foreign matter andcontaminants such as oil, dust,grease, frost, water, dirt, oldsealants or glazing compounds,protective coatings, originalformwork, etc.
Priming: Surfaces to receive A/DFIREBARRIER Mortar generally donot require priming.
Keying: For large horizontalopenings, it is recommended that
A/D FIREBARRIER Mortar bemechanically keyed into theconcrete surround and/or thatintermediate support be provided.Mixing:A/D FIREBARRIER Mortar
is mixed with water in the ratio of2.6 quarts US (2.5 L) of water toeach 15.5 lb. (7 kg) bag. An emptymilk container makes a convenientmeasuring device for water at the
job site. A measuring cup issupplied in each bag forconvenience when mixing less thana full bag. Portion water and Mortarpowder in accordance with Table 2.
Forming or Damming:Horizontal openings may bedammed temporarily with any
Table 1 - PHYSICAL PROPERTIES
Properties Results
Before CuringMix Time 1.5 to 5 min.
Pot Life 50 min. (max.)
Workability Excellent
Wet Density 43.7 + 0.6 pcf (700+10 kg/m)
Set Time 10 to 15 hr.
After Curing
Density 40 + 2.5 pcf (640 + 40 kg/m)
Compressive Strength (28 days) 478 + 44 psi (3.3 + 0.3 MPa)
Shrinkage None
Noncombustibility (ASTM E136) Noncombustible
Noncombustibility (CAN4-S114) Noncombustible
Thermal Conductivity (ASTM C-518)0.197 W/m.K @ 24C
(1.365 Btu. in/ft.h.F)
*Values given are not intended to be used in specification preparation.
8/11/2019 StonCor AD Firebarrier
19/23
October 2004
convenient material (i.e. plywood,polystyrene insulation boards, wiremesh, etc.). Damming is generallynot required for vertical openingsdue to the low slump, dimensionalstability and cohesive strength ofthe mortar paste. Forms, if used,may be removed after 24 hours.
Placement: Apply A/D FIRE-BARRIER Mortar paste intoopening with trowel, or pour intolarge horizontal openings frommixer or mixing container. Workpaste with trowel to ensure that allvoids are filled. Give particularattention to voids between multi-cable/pipe installations. Productmay be vibrated for this purpose.Tool surface to desired finish.Clean up with water.
Re-Penetration: Should it become
necessary to penetrate cured A/DFIREBARRIER Mortar for new oradditional building services (i.e.cables or pipes), simply drill or pokethrough mortar to provide openingof sufficient size. After installationof new penetrating item(s), firestopremaining voids with fresh A/DFIREBARRIER Mortar or with A/DFIREBARRIER Mineral Wool andSilicone where permitted by firetested system.
Precaution: Avoid inhalation of
dust or contact with eyes. Use ofdust mask and eye protection isrecommended. Thoroughly wash
skin after contact and before eating,etc.To safely use this product, read andabide by Material Safety DataSheet (MSDS).
5. AVAILABILITY AND COSTAvailability: A/D sales offices andtechnical representatives are
located throughout North America.(See below)
6. MAINTENANCENo maintenance should berequired. If mortar becomes dam-aged replace damaged portion.Damage by other trades should bepatched at the expense of tradecausing damage.
7. TECHNICAL SERVICESContact nearest A/D office.
A/D FIRE PROTECTION SYSTEMS
Table 2
A/D FIREBARRIER Mortar Powder Water
Full bag, 7 kg (15.5 lb.) 2.5 L (9 cups*)
(2.6 quarts US)
bag (32 cups*) 1.875 L (6 cups*)
(2 quarts US)
bag (21 cups*) 1.25 L (4 cups*)(1.3 quarts US)
bag (10 cups*) 0.625 (2 cups*)
(0.7 quarts US)
*Note: Refers to 275 mL cup supplied in bag. Use clean potable water.Add mortar powder to water in mixer or mixing container. Mix until themortar paste takes on a consistent mousse-like or shaving cream-liketexture. DO NOT ADD MORE WATER continue to mix until mixturewets out. Mixing time will depend on method used - 1 to 3 minutes formortar mixer, 3 to 5 minutes with electric hand-held mixer. Hand mixingmay take longer.
NOTE: DO NOT ADD MORE WATER. IT IS NORMAL FOR MIX TOAPPEAR QUITE DRY AT FIRST. CONTINUE TO MIX.
8/11/2019 StonCor AD Firebarrier
20/23
FIREBARRIERSEAL and SEAL NS
1. PRODUCT NAMEA/D FIREBARRIER Seal andSeal NS
2. PRODUCT DESCRIPTION
Single component, water basedelastomeric sealants intended foruse as firestop system components.
Basic Use: A/D FIREBARRIERSeal and Seal NS are designed foreconomical use in joint and servicepenetration firestop configurations.They form durable, flexible,watertight bonds with mostconstruction materials. In mostcases, no primer is required.Physical properties will remainstable over time.
Composition and Materials:A/D FIREBARRIER Seal may bepumped or poured into the opening.
A/D FIREBARRIER Seal NS (non-slumping) is designed for trowel andspray applications.
A/D FIREBARRIER Seal and SealNS contain water and must beprotected from freezing and fromwater until fully cured. Store,transport and install at temperaturesabove 40F (5C).Colors:A/D FIREBARRIER Seal isblue in color. Seal NS is available inwhite or red please specify whenordering. The white version of SealNS in 5 gal (18.9 L) pails may betinted in the field with a variety ofcolor tint pastes. Refer to Seal NSTintingdata sheet.Packaging: A/D FIREBARRIERSeal and Seal NS are available in 5US gallon (18.9 L) pails. Theoreticalcoverage per pail is 40 ft
2(3.8 m
2) at
an applied wet film thickness of 0.2in. (5 mm) and approximately 64 ft
2
(5.7 m2) at 1/8-in. (3 mm) wetthickness. Seal NS is also availablein 10.3 fl. oz. (304mL) and 28.7 fl.oz. (850 mL) tubes.
Application Limitations:
Do not install when ambienttemperature or temperature ofsubstrate is below 40F (5C).
Protect from freezing and wateruntil sealant is fully cured.
Do not install to surfaces withspecial protective or cosmetic
coatings without prior consul-tation with manufacturer andfirst testing adhesion.
Do not install where directcontact with food will occur.
Do not install where abrasion orphysical abuse is anticipated.
Seal is intended for horizontalapplications only. Seal NS canbe used for vertical andhorizontal applications.
Seal and Seal NS have beentested in numerous firestop joint
and through-penetration firestopsystems. For best economy andperformance the product shouldbe applied to a thickness equalto or slightly greater than theminimum test design thickness.Excessive depth to width ratiosmay cause sealant failure donot apply excessive thick-ness. As a guideline, werecommend that the minimum
test system thicknesses not beexceeded by more than 25%.
Standards: A/D FIREBARRIERSeal and Seal NS have been firetested in accordance with thefollowing: ULC-S115-M, StandardMethod of Fire Tests of FirestopSystems, ASTM E814-83 and
ANSI/UL 1479, Standard Method ofFire Tests of Through - PenetrationFire Stops and ANSI/UL 2079,"Tests for Fire Resistance ofBuilding Joint Systems."
3. TECHNICAL DATAA/D FIREBARRIER Seal and Seal
NS are listed by ULC, ULI, ITS andFM. For details of rated firestopsystems see ULI s Fire ResistanceDirectory, Volume 2, ULC s List ofEquipment and Materials, FirestopSystems and Components, ITS' sListings Book and FM s ApprovalGuide.ULC: JF9, -29, -50, -51, -93, -99
and -100. HW36, -38, -39, -40,-41, -42, -43, -44, -45, -46, -47,-48, -49, -50, -51, -52, -53, -54,
Table 1 - PHYSICAL PROPERTIES
ResultProperty
Seal Seal NS
Uncured
Color blue white or red
VOC (ASTM D3960) 0.2 lb/gal US (26 g/L) 0.23 lb/gal US (27 g/L
% Volatile by volume (ASTM D2697) 43.0 41.9
Tack Free Time*, hours 4 1
Curing Time*, hours 24 96
Brookfield Viscosity (nominal),centipoises
10,000
(LVF, spindle 4
@ 5 rpm)
200,000
(RVT, spindle E
@ 10 rpm)
pH 9.1 8.5 8.8
Weight per Gallon, lb / imp. gal. 13.5
Cured
Color blue white or red
Dirt Resistance Excellent
Tensile Strength (ASTM D412), psi 330 365
Tensile Strength (ASTM D2370), psi 385
Elongation at break (ASTM D412), % 255 350
Elongation at break (ASTM D2370), % 370
* Curing time will vary with temperature, humidity and thickness.
Values given above are not intended for specification preparation.
8/11/2019 StonCor AD Firebarrier
21/23
-55 and -56.SP218, -219, -220, -221, -759,-761, -881, -882 and -1080.
ULI:CAJ-1125, -1127, -1324 and 1450. FF-D-1032 and -1038. FW-D-1029 and -1036.HW-D-0060, -0061, -0118, -0119,-0120, -0247, -0249, -0250, -0254,-0282, -0301, -0302, -0303, -1012,
-1020 and -1029. WW-D-1033.FM:90, 93, 95.ITS:AD/PH 180-01, -02 and -03.
AD/PHV 120-01, -02 and -03,180-09, -10, -11 and -12.
4. INSTALLATIONClean all openings to be firestoppedby removal of foreign matter andcontaminants such as oil, dust,grease, frost, water, surface dirt, oldsealants, glazing compounds,protective coatings etc.Cleaning of all surfaces should be
done on the same day in which thesealant is applied.
Priming: A/D FIREBARRIER Sealand Seal NS generally do notrequire priming. In view of theunpredictability of surface charac-teristics, it is recommended that atest sample of sealant be applied onthe surface to test adhesion.
Masking: Areas adjacent toopenings to be firestopped can bemasked to assure a neat
appearance. The masking tapeshould not be allowed to touch theclean surface to which the seal is toadhere. Remove masking tapeimmediately.
A/D FIREBARRIER Mineral Wool isthe required backup material forfirestops.Install backup materials asspecified.A/D FIREBARRIER Seal isintended only for horizontal
applications. Check fire test designfor required thickness - usually 0.2in. (5 mm) wet. Pour or pump Sealin a continuous operation to fill andseal the opening. A light pass with
a trowel over the surface of the sealwill ensure a smooth surface.A/D FIREBARRIER Seal NSis non-slumping and may be sprayed ortrowelled for vertical and / orhorizontal applications. For sprayapplications refer to Table 2. Checkfire test design for requiredminimum wet film thickness -usually 0.2 in. (5 mm) or 1/8 in. (3.2mm).Excess sealant should be wipedfrom glass, metal and plastic
surfaces while uncured. Clean up iswith water.CURED SEALANT IS USUALLYVERY DIFFICULT TO REMOVEWITHOUT ALTERING OR DAM-
AGING THE SURFACE TO WHICHTHE SEALANT HAS BEEN
APPLIED.
Precaution: May cause irritation.May be harmful if swallowed. Avoidgetting in eyes. Wash hands
thoroughly after handling. Use onlyas directed.Keep out of reach of children.To safely use this product, read andabide by Material Safety Data Sheet
(MSDS).
Shelf Life:When stored at or below80F (27C) and above 40F (5C),
A/D FIREBARRIER Seal and SealNS have a shelf life of one yearfrom date of manufacture.Note:Protect from freezing.
5. AVAILABILITY AND COSTAvailability: A/D sales offices andtechnical representatives arelocated throughout North America.(See below)
6. MAINTENANCENo maintenance should be required.If seal becomes damaged, replacedamaged portion. Clean surfaces indamaged area and repair with fresh
A/D FIRE-BARRIER Seal or SealNS. Damage by other tradesshould be patched at the expense oftrade causing damage.
7. TECHNICAL SERVICESContact nearest A/D office.
A/D FIRE PROTECTION SYSTEMSHead Office: 420 Tapscott Road, Scarborough, Ontario, M1B 1Y4
Tel: (800) 263-4087 or (416) 292-2361 Fax: (416) 298-5887
www.adfire.comContact By State or Province
AK, AR, AZ, CA, CO, HI, ID, LA, MT, NM, NV, OK, OR, TX, WA, WY, UT: Tel: (888) 323-3473, Fax: (949) 458-9220
AL, CT, DC, DE, FL, GA, IA, IL, IN, KS, KY, MA, MD, ME, MI, MN, MO, MS, NC, ND, NE, NH, NJ, NY,OH, PA, RI, SC, SD, TN, VA, VT, WI, WV: Tel: (800) 650-0881, Fax: (613) 841-7768
NB, NF, NS, PE, QC: Tel: (800) 914-6506, Fax: (450) 661-8776
AB, BC, MB, ON, SK: Tel: (800) 263-4087, Fax: (416) 298-5887
Table 2 Quick Reference Guide - Spray Application of Seal NS
Hoses300 ft max.
50ft of 3/8 in. dia. & 250 ft of 1/4 in. dia.
Whip line 9 ft whip line with swivel
Tips 5/17 heavy-duty self cleaning reversible type
Spray machineAirless sprayer capable of 3000psi pressure and min. delivery
of 1.0 gpm without surging
Filters 60-80 mesh in gun & 60-80 in manifold
Mixing Heavy-duty drill with paddle for 2 min.
Application Rate 1/8 in. (3 mm) wet
Finish Follows profile of backer material
Trowel May be toweled
Clean-up 10 gal water
April 2004
8/11/2019 StonCor AD Firebarrier
22/23
SELLOS CORTA FUEGO Y HUMO
ESPECIFICACIN SECCIN 078601 General1.1 LA SECCION INCLUYE
0.1 Cumplir con la Divisin 1, Requisitos General y Documentos referidos aqu0.2 Es la intencin de esta seccin de las especificaciones de establecer una nica,
y competente fuente que sea responsable de proveer toda la mano de obra,materiales, productos, equipos y servicios, para suministrar e instalar el trabajodel sistema de corta-fuego y sello de humo para toda la obra.
1.2 TRABAJO RELACIONADO ESPECIFICADO EN OTRO LUGAR(Especificar)
1.3 SECCIONES RELACIONADAS(Especificar)
1.4 ESTANDARES DE REFERENCIA0.1 (ANSI/UL 1479 - Pruebas de Fuego de Corta Fuego a Travs de Penetraciones)
(CAN4-S115-M85 - Mtodo Estndar de Pruebas de Fuego de Sistemas CortaFuego) (ASTM E814 - Mtodo de Prueba de Pruebas de Fuego de Corta Fuegoa Travs de Penetraciones) (ANSI/UL 2079 - Pruebas para Resistencia al Fuegode Sistemas de Juntas para Edificios).
1.5 DESCRIPCION DEL SISTEMA0.1 Materiales Corta Fuego: Proveer Sistema(s) Corta Fuego para proveer y
mantener una clasificacin de resistencia al fuego, como est indicado en losPlanos y de acuerdo a los detalles de diseo de UL, WH, ULC, cUL o FM.
1.6 REMISIONES (Submittals)0.1 (Especificar) (datos del fabricante) (planos de taller) (muestras)
1.7 ASEGURAR CALIDAD0.1 Fabricante: Compaa especializada en fabricacin de productos de esta Seccin
con un mnimo de tres (3) aos de experiencia documentada, y un sistema de
gerencia de calidad registrado de acuerdo con los requisitos de ISO 9001:2000.0.2 Aplicador: Compaa que tenga un mnimo de tres (3) aos de experiencia enla instalacin de los materiales aqu especificados en proyectos comparables aeste proyecto.
1.8 REQUISITOS DE NORMAS0.1 Cumplir con (Cdigos de Construccin locales), listados de (UL) (ULC) (cUL)
(ITS) (FM) y (ANSI/UL 2079) (CAN4-S115) (ASTM E814) prueba de fuegoestndar para obtener la clasificacin de proteccin al fuego requerida.
1.9 REQUISITOS AMBIENTALES0.1 Cumplir con las recomendaciones de instalacin del fabricante en cuanto a
temperatura, humedad, y condiciones de ventilacin.
1.10 ENTREGA, ALMACENAJE Y MANEJO0.1 Entregar materiales al sitio de la obra en los envases originales del fabricante,
intactos sellados y etiquetados por el fabricante. Manejar y almacenar losmateriales de acuerdo a las instrucciones del fabricante.
1.11 CONDICIONES DEL PROYECTO/SITIO DE OBRA0.1 Cumplir con los requisitos recomendados del fabricante en cuanto a
temperatura, humedad relativa y condiciones del substrato durante la aplicaciny curado de los materiales.
1.12 SECUENCIA Y PROGRAMACIN0.1 Coordinar con otras Secciones relacionadas. Programar el trabajo de otras
actividades de manera que las aplicaciones de corta fuego puedan serinspeccionadas antes de ser cubiertas por construccin subsecuente.
2 Productos2.1 FABRICANTES ACEPTADOS
0.1 Proveer corta fuego de selladores de silicona, selladores a base de agua, morteros,o sistemas corta fuego del siguiente fabricante: A/D Fire Protection Systems.
2.2 MATERIALES0.1 Los material(es) deben ser: A/D FIREBARRIER Mineral Wool (Lana Mineral) A/D
FIREBARRIER Silicone and Silicone SL (Silicona) A/D FIREBARRIER Mortar(Mortero) A/D FIREBARRIER Collars (Collarines) A/D FIREBARRIERIntumescent Caulk (Calafateo Intumescente) A/D FIREBARRIER Pillows(Almohadas) A/D FIREBARRIER Seal and Seal NS A/D FIREBARRIER
SprayMastic A/D FIREBARRIER Wrap Strip (Banda para Enrollar) A/DFIREBARRIER Putty (Masilla) A/D FIREBARRIER Putty Pads (Pads de Masilla)A/D FIREBARRIER Inserts (Pads de Masilla pequeos).
0.2 Clasificaciones de Sistemas Corta Fuego: Cumplir con los requisitos de cdigode construccin aplicable para las ubicaciones y horas de clasificacin contrafuego de las designaciones (F) (T) (FT) (FH) (FTH).
0.3 Materiales de relleno y soporte trasero, soportes y anclajes deben ser deacuerdo a las recomendaciones del fabricante, del sistema/diseo de cortafuego probado, y aceptable a las autoridades que tienen jurisdiccin.
0.4 Base antioxidante: como sea requerido por el fabricante, y que sea compatiblecon el sistema y los materiales contiguos.
0.5 Agua: Potable
3 Ejecucion3.1 EXAMINACION
0.1 Examinar substratos, aberturas, espacios, construccin adyacente, ycondiciones bajo las cuales el corta fuego va a ser instalado. Confirmarcompatibilidad con las superficies.
0.2 Verificar artculos que penetran estan fijados en forma segura, y ubicadosdebidamente dejando el debido espacio entre las penetraciones y las superficiesde las aberturas.
3.2 PREPARACION0.1 Las superficies que van a recibir el corta fuego deben estar libres de sucio,
polvo, grasa, aceite, xido, materiales sueltos, agentes de separacin,congelacin, humedad o cualquier otro material que impida la unin delmaterial corta fuego al substrato o artculo penetrante(s).
0.2 Aplicar base antioxidante a los substratos de acuerdo con las instruccionesescritas del fabricante.
0.3 No aplique corta fuego y sellos de humo a superficies previamente pintadas otratadas con selladores, compuestos de curado, repelentes de agua o otrosrevestimientos a menos que se hayan hecho pruebas que asegurencompatibilidad de materiales. Remueva los revestimientos que sean requeridos.
0.4 Asegurar que los anclajes, materiales de soporte, clips, mangas, soportes yotros materiales relacionados usados en las pruebas de fuego sean utilizados.
0.5 Cubrir cuando sea necesario, para prevenir que los materiales corta fuegohagan contacto con superficies adyacentes que quedarn expuestas durante eltrabajo. Remover la cinta adhesiva tan pronto sea posible sin daar el materialcorta fuego o el substrato.
3.3 INSTALACION0.1 Cumplir con los listados de (UL) (ULC) (cUL) (ITS) (FM), y con las
instrucciones del fabricante para el tipo de material y condicin de la aberturaen cada caso. Consultar con el fabricante para determinar el procedimientoadecuado para las condiciones no totalmente cubiertas en las instruccionesescritas. Registrar por escrito cualesquiera instrucciones recibidas, con copiaal fabricante.
0.2 Remover material corta fuego excedente prontamente en lo que el Trabajoavanza y cuando sea terminado.
0.3 Proveer bloqueos a prueba de goteos tal como sean requeridos para sellaraberturas y contener el material corta fuego hasta que se haya curado. Instalarlos bloqueos de acuerdo al diseo de prueba y las instrucciones del fabricante.
3.4 CONTROL DE CALIDAD DE CAMPO0.1 Notificar al Consultor cuando las instalaciones terminadas estn listas para ser
inspeccionadas antes de encerrar o tapar las reas que contienen los materialescorta fuego.
0.2 Organizar las inspecciones por la compaa de inspecciones y pruebasindependiente del Propietario, seleccionada y pagada por el Propietario.
0.3 Siguiendo las inspecciones de campo, proveer toda reparacin como searequerido para asegurar cumplimiento con los Documentos del Contrato.
3.5 LIMPIEZA Y PROTECCIN0.1 Al terminar este trabajo, remover todos los materiales, equipo y materiales
sobrantes del sitio de la obra. Dejar el rea de trabajo y superficies adyacentesen una condicin aceptable al Consultor.
8/11/2019 StonCor AD Firebarrier
23/23
StonCor South Cone con ms de 30 aos de experiencia en el pas, empresa del Grupo RPM,
ofrece al mercado industrial una solucin integral en la proteccin anticorrosiva.
Dicha solucin est compuesta por tres lneas de productos:
Stoncor South Cone S.A.
Einstein 1095 - Parque O.K.S.
(B1619JWA) Garn-Bs.As.
(54) 03327-442222 - Fax:442223
www.stoncor.com
South C o ne
Carboline Company
350 Hanley Industrial Court
St. Louis, MO 63144-1599
1-800-848-4645
Fax. 1-314-644-4617
www.carboline.com
Planta Industrial Garin - Arg