<MUPUS> Status Venice, 30-Mar-1-Apr 2009

Philae STW 2009

Page 2: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

2 LOWG#12, DLR Cologne 18-20th of November 2008

Main Events with MUPUS participation (since last Philae STW)

PC#8 PC#9 Steins fly-by Thermal Characterization 2

Page 3: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

3 LOWG#12, DLR Cologne 18-20th of November 2008

PC8 Summary

Software Patch V7.2 successfully uploaded Burned to EEPROM x0000 after verification during PC8

MUPUS worked flawlessly during PC8 3 procedures executed

Active Checkout 1 (basic tests, repetition of PC4) Active Checkout 2 (performance , revised version of PC4 test) Inflight calibration (standard checkout procedure)

164 TC‘s send and executed without error Detailed testing of nearly all MUPUS modes in different configurations

5610 science data packets produced without problems Active thermal conductivity measurement mode tested first time in

flight Performance improved

ANC-M sampling frequency 47.8 kHz (from 33 kHz) ANC-T measurements added to ANC mode PEN and TM calibration (sensitivity loss confirmed) improved

Page 4: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

4 LOWG#12, DLR Cologne 18-20th of November 2008

PC8 THC Mode

PEN12 heated with 150 mW for 20 minutes

Page 5: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

5 LOWG#12, DLR Cologne 18-20th of November 2008

MUPUS PEN calibration PEN sensors calibrated on ground between

-40°C and +50°C Data of limited quality

Inflight calibration needed to cover low T expected for the comet

Method: Use Pt-100 in the holder as reference Assume that PEN tube and holder at the

same temperature in equilibrium (before PENEL switched on, justified by TV test with PEN FS)

Interpolate resistance backward in time to start of PENEL preheating (equilibrium)

=> Ri=Ri(Tref), i=1,2,…,16 5 inflight calibration points between -107°C

and -96°C points acquired since PC#6

PEN1

PEN16

TCU-MUPUS-DD

Pt-100

PENEL, T=-50°C

Page 6: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

6 LOWG#12, DLR Cologne 18-20th of November 2008

Steins Flyby Results

MUPUS worked flawlessly during Steins flyby 4607 science data packets

produced during continous MUPUS TEM mode operations for 17 h around CA

No communication problems Magnetometer measurements

disturbed Temperature rise of PHILAE

balcony detected with all MUPUS sensors Strong gradient after spacecraft

flip (especially for ANC-T) MUPUS inflight calibration data

gives consistent PEN temperature readings

Page 7: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

7 LOWG#12, DLR Cologne 18-20th of November 2008

THC2 Results 1, PEN temperatures

Using only inflight calibration points (linear extrapolation) !

Page 8: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

8 LOWG#12, DLR Cologne 18-20th of November 2008

THC2 Results 2 (Calibration comparison)

- Most PEN sensors stable since ground calibration in 2001- 5 PEN sensors have changed R(T) characteristics

Page 9: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

9 LOWG#12, DLR Cologne 18-20th of November 2008

THC2 Results 5 (ANC-T temperatures)

- ANC-T temperatures not strongly dependent on E-Box temperature- Differences between ANC-T and TCU-Anchor sensors probably real

Page 10: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

10 LOWG#12, DLR Cologne 18-20th of November 2008

THC2 Summary MUPUS worked flawlessly during THC2

7907 science data packets produced during continous MUPUS TEM mode operations for 75 hours

Strong temperature rise of PHILAE balcony detected with all MUPUS sensors Highest balcony temperature recorded in flight MUPUS inflight calibration gives consistent PEN

temperature readings 5 PEN sensors changed R(T) characteristics since ground

calibration ANC-T temperatures consistent with TCU anchor sensors Very useful for improvement of MUPUS calibration !

Thanks to LCC, SONC, and ESA !

Page 11: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

11 LOWG#12, DLR Cologne 18-20th of November 2008

Experiment Status for Cruise

ScROP Requests closed R_LZ021: MUP_8 Repetition of MUPUS PC4 Tests with revised

MUPUS SW R_ LZ023: MUP_13 MUPUS Software patch V7.2 R_LZ095: MUP_12 MUPUS Participation in PHILAE Thermal

Characterization tests Open ScROP Requests

R_LZ022: MUP_10 EEPROM refresh procedure R_LZ070: MUP_11 MUPUS Participation in PHILAE interference tests R_LZ071: MUP_15 Test of the MUPUS on-comet first science

sequence procedure R_LZ107: MUP_16 Test of the MUPUS on-comet monitoring procedure

NCR Status All MUPUS NCR’s closed

Page 12: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

12 LOWG#12, DLR Cologne 18-20th of November 2008

Remaining Cruise Activities

PC10 Operations R_LZ017: MUP_4 MUPUS In-Flight Calibration R_LZ070: MUP_11 MUPUS Participation in PHILAE interference

tests PC12 Operations

R_LZ017: MUP_4 MUPUS In-Flight Calibration R_LZ022: MUP_10 EEPROM refresh procedure R_LZ071: MUP_15 Test of the MUPUS on-comet first science

sequence procedure (joint PHILAE test) R_LZ107: MUP_16 Test of the MUPUS on-comet monitoring

procedure (joint PHILAE test) Lutetia Operations

Preferably as during Steins/THC2 (tbc, ROMAP ?) PC13 Operations

R_LZ017: MUP_4 MUPUS In-Flight Calibration

Page 13: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

13 LOWG#12, DLR Cologne 18-20th of November 2008

MUPUS during SDL

TM calibration during descent (R-SDL-1, MUPUS FOP) TM has lost sensitivity Unique opportunity for inflight calibration with undisturbed known

background ANC-M acceleration measurements at touchdown (R-SDL-4)

Starts with pre-trigger (ringbuffer) mode (Interrupts enabled, SST evaluated)

Information from CDMS by SST about selected anchor for firing required at least 100 ms before firing (R-SDL-5)

ECR By MUPUS on CDMS raised 2006, CDMS fulfilled (A. Balasz) INT4 (hardware) trigger starts sampling with 48 kHz for about 650 ms (1

RAM page, 64 kByte !), Interrupts disabled ! Pre-trigger mode, software checks SST again for either:

safe anchoring => finish ANC mode, start data transmission to CDMS firing of next anchor, then data transmission to CDMS

Read the FOP !

Minimum time (> 0.65 s) needed between two anchor shots to be analyzed !

Page 14: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

14 LOWG#12, DLR Cologne 18-20th of November 2008

SDL cont., ANC-T Thermal diffusivity

Extension of MUPUS operation during SDL until at least 1 h after touchdown for ANC-T thermal diffusivity measurement (R-SDL-6) Deepest thermal properties measurement of a comet ! Combine with Thermal Inertia measurements (one full rotation ~ 12-13 h)

during FSS (keep MUPUS ON for a full rotation of the comet) to save ressources.

Read the FOP !

Page 15: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

15 LOWG#12, DLR Cologne 18-20th of November 2008

MUPUS during LTS

MUPUS is a longterm experiment aimed at detecting changes in subsurface structure caused by increasing activity => Landing in an „active region“ (R-LT-2) Activity is the KEY PROPERTY of a COMET !

MUPUS should be operated whenever feasible during LTS (R-LT-1) Operation at least once a week for a full rotation (R-LT-3/4)

Page 16: Status Venice, 30-Mar-1-Apr 2009 Philae STW 2009

16 LOWG#12, DLR Cologne 18-20th of November 2008

Scientific activities

MUPUS Team Meeting in May 2009 (Graz) MUPUS Flight operations (update of FOP) Thermal properties measurement method

Assessment of reference methods and materials Definition/Characterization of MUPUS internal standards Lab experiments + thermal modelling

Improvement of temperature calibration Thermal modelling + Lab Experiments

Science Themes Inputs Delivered to Lead Scientists in August 2008 (Minor) update Feb. 2009

New approach for thermal modelling of active regions Moving boundaries, Stefan problem (E. Kührt, N. Gortzas)