CFAS Enterprises Inc. After Market Utility Power Equipment Brokerage Mailto:[email protected] Turbine URL: http://CFASPower.com/Index.html Reciprocating URL: http://CFASPower.com/Recips.html GTG_1400OM_P18PC4_60Hz.doc 5 x Pielstick 18PC4-18MW (90Mw) 60Hz HFO Generating Plant

Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

Embed Size (px)

Citation preview

Page 1: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

CFAS Enterprises Inc.After Market Utility Power Equipment BrokerageMailto:[email protected] URL: http://CFASPower.com/Index.htmlReciprocating URL: http://CFASPower.com/Recips.html

GTG_1400OM_P18PC4_60Hz.doc

5 x Pielstick 18PC4-18MW (90Mw) 60Hz HFO Generating Plant

Page 2: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

Price for entire plant: US $720,000 EACH The engines are HFO/bunker fired. HFO treatment plant is included. EnginesMake Chantier De L' Atlantique (France)Model 18PC4 Pielstick EngineType Turbo Charge With Governor, Four Cycle, Single Acting, Solid Injection, Water Cooled, Vee Type, Trunk Piston, Forced

Lubricated, Supercharge Stationary Diesel EngineAir Started:Turbo-Chargeer: Chantier's De L'AtlantiqueRated Capacity: 18MWHorse Power Rating: 2700HPHorse Power: 26,650 Bhp Rated Continuous OutputNo. Of Cylinder: 18Rpm: 400Cylinder Bore: 570mmPiston Stroke: 620mmBMEP At Rated Output: 20.4 Kg/ Cm2 At SiteMaximum Combustion: 120 Kg/ Cm2Mean Piston Speed: 8.3 M/S

Page 3: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

Total Length: 12, 800 MmWidth: 4, 480 MmHeight For Crank Center: 4, 550 MmWeight: 282 Tons

GeneratorsMake: CEM Cie Electro MecaniqueType: WAPD 284110/18Rated Capacity: 24,100 KvaTerminal Voltage: 13, 800 VAmps. 1008 AFrequency: 60 HzRpm: 400Power Factor: 0.80Phase 3Protection: IP 20Insulation Class: FWeight: 80 Tons

ExcitationType: Brushless RK 105-18Voltage: 82 KvAmps: 790a

GovernorMake: Regulateurs Europa Ltd. EnglandType : 1502/ 26 Series 1500Maximum Output: 0-10Working Capacity: 270 J, Working Press 21 Kgf/Sq CmInput Speed: 230-1150 Rpm Working Pressure: 21 Kgf./Sq CmInput Speed: 230-1150 Rpm

With Mechanical & Electrical Auxiliaries.

ENGINE-GENERATOR

1 Diesel Electric Generating Set-5 set 1977a. Diesel Engine:Chantiers de Atlantique SEMT Pielstick, Type 18P4, 18-cylinder,2700 hp, 400 rpm, turbo-charged, with governor, unit completewith machinery foundation, local control panel, installation andstandard accessories.

b. Electric Generator-5 set 1977. Consisting of five (5) units installed A.C. Generator -CEM (CieElectro- Mesanique), France, Type WAPD284-110/18, 24100 KVAcapacity, 0.8 p.f.. 13,800 volts, 400 rpm, 3-phase 60-cycle, with158 kw rating DC generator, Type ET98-30, 23 TV, 400 rpm, CI-F.complete with bearing and accessories.Unit 1 SN - 7020Unit 2 SN - 7021Unit 3 SN - 7022Unit 4 SN - 7023Unit 5 SN - 7024: with few accessories within the powerhouse premises only

Page 4: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

Unit 6 SN -7025

ACCESSORY ELECTRICAL EQUIPMENT

1. Main Control Switchboard-1 lot 1977. Cie Electro-Mecanique, consists of: Duplex type controlswitchboard, consisting of: 6 - Generator Control Panels. 6-EngineControl Panels, 1 - Transformer Main Control Switchboard, 1 -Station Service Transformer Control Panel Switchboard completewith meters and relaying equipment, bus potential transformers,control switches, annunciator boxes, indicating lamps, panelbuttons, terminal block and accessories. Located at control room.

2. 15 KV Metal Clad Switchgear-2 set 1977. Alsthom, indoor type consisting of fourteen (14) cubicles, with circuit breakers assemblies, potential transformer, current transformers, capacitor, resistors, indicating lamps, terminal blockand bus bar interconnections and other accessories. Located at 2nd Floor near 12PC2.5 side.

3. 440 V Station Service Switchgear (LV)-1 lot 1977. Redon Dalmon, compartmentalized panel, consisting of several drawers housing, draw-out type circuit breakers, meters, relays, control switches, signal lamps. fuses, terminal blocks and bus bar interconnections. Located at control room.

4. 125 V DC Panel (12PC2.5) 1 unit 1975 0.0254% Drawer type panel for 125 VDC, distribution branch circuits, complete with circuit breakers, control switches. meters, relays, signal lamps and accessories. Located at control room.

5. 115 V AC Panel (12PC2.5)-1 unit 1975. Drawer type panel for 115 V AC, distribution branch circuits, complete with circuit breakers, control switches, meters, relays, signal lamps, terminal blocks and accessories. Located at control room.

6. Station Battery Equipment-1 lot 1977. Consisting of: Two (2) - Station Battery Bank - Yuasa and Oriental, 60 cells/bank, 125 volts and one (1) . Battery Chargers - CoredeL, complete with voltmeters, ammeters, lights and switches. Locatedat battery room.

7. Cable Trays-1 lot 1977. Steel, locally fabricated in various sizes, complete with supports and hangers.

8. Power and Control Cables-1 lot 1977. Consisting of various sizes and capacities of cable wires, insulated type, complete with connectors, grounding cables, insulating materials and other accessories.

9. Motor Control Center Panel-1 unit 1977. BBC,(Common) consisting of: MCC Panel - 7 sections, system complete with circuit breakers, selector and Band sectionalizing switches, resistors, relays. signal lamps, terminal blocks and buswiring and other accessories. Located at ground floor of powerhouse.

10. Motor Control Center Panel-6 unit 1977. BBC, consisting of: MCC Panel . 6 sections, system complete with circuit breakers, selector and sectionalizing switches, resistors, relays, signal lamps, terminal blocks and bus wiring. Located atground floor of powerhouse.

Page 5: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

11. Motor Control Center Panel-1 unit 1975-Dalmon, (Common) consisting of MCC panel, 4 section, complete with circuit breaker, switches, relays, lamps, wirings, and other accessories. Located at 2nd floor of powerhouse, 12PC2.5.

12. Excitation Cubicle- 6 unit 1977. Complete with line voltage, excitation voltage and excitation current. Located at control room.

13. 115 VAC Panel-1 unit 1977. 18PC4 plant system. Located at control room.

14. 125 VDC Panel-1 unit 1977. 18PC4 plant system. Located at control room.

Page 6: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

STRUCTURES AND IMPROVEMENTS

1. Powerhouse/Control and Office Building 1 unit-1977. This is a three storey, reinforced concrete framed bldg. with sandblast finish reinforced concrete walls and aluminum sidings at the portion, corrugated aluminum sheet roofing on the steel frames, granolithic tile and steel grating finish generator floorlevel, metal louvers, steel awning windows, with glass panes andsteel roll-up doors. Control and office bldg. are housed in the adjoining three storey bldg with vinyl tile finish flooring, acoustic board ceiling on aluminum T-runner, concrete hollow block partitions, and plywood flush type and glass on aluminum frame doors. The bldg. is painted and provided with electrical lighting. Plumbing facilities and/or air conditioning system. Total floor area is approx. 12,645 sq.m. Located at plant compound.

2. Water Treatment Shed-1 unit-1980 One story open building with timber post, corrugated GI sheet roofing on timber frames, plain cement finish concrete floor, provided electrical lightings. Floor area is approx. 18 sq.m.Located at plant compound.

3. Pump Houses (HFO) 2 unit 1977. These are one storey concrete framed bldg., with plastered concrete block walls, corrugated GI sheet roofing on timberframes, plain cement concrete finish floor, wood sash windows with glass panes and plywood flush type door. Painted and provided with electrical lighting. Floor area is approximately 1 5 sq. m. Located at tank farm.

4. Pump Houses (LFO) 1 unit 1977. These is one storey, concrete framed bldg with plastered concrete block walls, corrugated GI sheet roofing on timber frames, plaincement finish concrete floor, wood sash windows with glass panesand plywood flush type door. Painted and provided with electrical lighting. Floor area is approx. 15 sq.m. Located at plant compound.

5. Fire fighting Pump House-1 unit 1977. A one storey concrete framed bldg. with plastered concrete CHBwalls, corrugated GI sheet roofing on timber frames, plain cementfinish concrete floor, asbestos ceiling, steel grilled window openings and plywood flush-type door. It is provided with electrical facility. Floor area is approx. 25 sq.m. with one side 10ft high firewall. Located at plant compound.

6. Firefighting Foam House-1 unit 1977. A one storey concrete framed bldg., with plastered concrete CHB walls, corrugated GI sheet roofing on timber frames, plain

Page 7: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

cement finish concrete floor, asbestos ceiling, steel grilled door. It is provided with electrical lighting. Floor area is approximately 25 sq. m., with one side 10 ft. high firewall. Located at tank farm.

7. Radiator Support Structure-1 Lot 1977. A one-story concrete framed structure, which supports the air-to-air radiator units. Column size is 0.90 m. x 0.90 m. x 5 m. high.Total number of columns is 119. The beam size is approx. 0.70 m. x0.90 m., column spacing is 6.0 m. Located at radiator area.

8. Fire Pond-1 unit 1977. It is a semi-underground concrete storage tank with a size of 22 m.long by 10 m. wide, and about 5 m. deep. The wall thickness is about 0.20 m. and the tank has a concrete slab cover. Located at plant compound.

9. Maintenance Shop-1 unit 1977. A one storey bldg. partially open with corrugated metal roof on timber frame, timber column, plywood ceiling, CHB watt on onebay, plain cement flooring, glass jalousie window plywood flushtype door and electrical facility. Located at plant compound.

10. Bund Wall For Settling Tank-1 unit 1977. It is a cast-in-place reinforced concrete wall about 0.20m thick,2.4m high and total length is 80m. Located at plant compound.

11. Sludge Pool-Sludge Pool 1 unit 1977. One story structure with corrugated GI roof, timber frame 2.5high, CHB wall. Total area is 50 sq. m. Located at tank farm.

12. Cable Trench-1 lot 1977. It is made of cast-on-placed concrete with concrete cover 0.15m thick wall and floorings. Located at front of powerhouse.

13. Oil I Water Separator-2 unit 1977. A one storey concrete structure, reinforced concrete wall anddivisions about 6.82 m long, 3.2 m and wall thickness of 18 cm.Located at tank farm.

14. Fuel Recovery Plant-1 unit 1977. A one story concrete structure, reinforced concrete wall and divisions provided with electrical lighting facilities. About 18.5 m long, 10.5 m wide, with a height of 2.5 m and wall thickness of 18 cm. Located at tank farm.

15. Oil I Water Separator-2 unit 1977(1) A 417 cm long, 310 cm wide and 16 cm wall thickness concretestructure.(2) A 186 cm long, 238 cm wide and 10 cm wall thickness concrete structure with 4 cm diameter tube fence. Located at tank farm.

16. Fuel Measuring Shed / Post-PC 1977. This is an open frame post with corrugated iron sheet roofing witha total height of 418 cm. The structure is provided with 152 x 148 x 190 cm (LWH) upper deck accessible by metal sheet stairs. Locatedat plant compound.

17. Flag Pole-PC. This is a 3Oft. metal pole, 8 inches in diameter with concrete foundation Located at plant compound.

FUEL HOLDERS, PRODUCERS AND ACCESSORIES

Page 8: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

1. HFO Storage Tank 3 unit 1977 1.1234, 5 million liters capacity steel plate welded construction. 21.04 m x 14.60 to high outside dimension, with heater, complete withsteel ladder platform and other accessories. Located at tank farm.

2. HFO Sludge Storage Tank (Tank Farm) 1 unit 1977. 2.7 million liters cp., steel plate welded construction, 16.507 m dia 12.82 m high outside dimension, complete with steel ladder platform and other standard accessories. Located at tank farm.

3. Light Fuel Oil Day Tank-1 unit 1977. Mild steel plate welded construction, 2743 mm dia x 6069 mm long outside dimension, saddle support, catwalk platform and other accessories. Located at plant compound.

4. HFO Day Tank-6 unit 1977 0.1381% Mild steel plate welded construction, 2.14 m dia. 6.7 m length dimension, saddle support, catwalk platform, heater, with thermostatic controls and other accessories. Located at back of powerhouse.

5. LFO Storage Tank-1 unit 1977. 500KL cap., steel plate welded construction. 8 m. dia x 11.58 to outside dimension complete with catwalk, heater, and other.

6. HFO Settling Tank-2 unit. 100KL cap,, mild steal plate welded construction, 6 m dia x 6 to high outside dimension complete with steam heater and ladder and other accessories. Located at back of powerhouse.

7. Sludge Tank-1 unit 1975. 211 cap., mild steel plate welded construction, 1219 mm dia 1829 mm long outside dimension with heater and other

8. Drip Tank-3 unit 1977 0. Mild steel plate material of welded construction, 2 m dia x 6.7 mlong on steel saddles with steam heater and other accessories.Located inside 1BPC4 powerhouse,

9. HFO Transfer Pump-2 unit 1979. Type 4V200, 50 cu.m./hr. cap., each driven by 11 kv electric motor, 460 volts complete with pipings and valves other accessories. Located at tank farm. land

10. HFO Final Filters-12 unit 1977. Eurofilter WinsLow, type J-68-164-A-P7-CS-T-IN, complete with 68fitter elements with 6 heaters (1 per engine). Located at 1BPC4powerhouse.

11. HFO Filter-2 unit 1975. Winslow, Type J-24-1 645-A- P1 2-CS•T-lN, with 24 filtering elementsand pipings (Note: Two (2) units per system. Located at 12PC2.5area.

12. LFO Transfer Pump -1 unit 1977. Mouvex series Nos. AR 338544, each with: 11 kw drive motor-CEM,complete with piping and other accessories.

13. Drip Transfer Pumps-3 unit 1977. Mouvex, Type AX-310, 7 cu. m./hr. capacity, each driven by 2.2 kwelectric motor. 460 volts and other accessories. Located at groundfloor of powerhouse. Note: one tank and one pump for every two engines.

Page 9: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

14. Fuel Piping System-1 lot 1977. Heavy and light fuel piping system of various sizes complete withasbestos, insulator, valves, fitting and flange connection withinthe tank farm and plant compound. Located at plant compoundand tank farm.

15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l<CA/hr. capacity, withthermostatic control and capillary tubes with valves andaccessories. Located at ground floor of powerhouse.

16. Sludge Tank-1unit 1977. Mild steel plate material of welded construction, 1.9m dia x 4mlong with heater, pipings and valves and other accessories. Locatedat sump pit area of powerhouse.

17. Sludge Pump-3 unit 1977.Merger, Type RM7M100/4, 3 cu.m./. capacity, driven by 7.5 kwelectric motor, 460 volts. Located at sump pit area of powerhouse.

18. HFO Centrifugal Separator-3 unit 1991. Westphalia Type OSB 35.02.066, 15 kw motor complete withpipes, valves and control panels. Located at ground floor ofpowerhouse.

19. Fuel Oil Pump (for HFO Engine Feed)- 5 unit 1977. Mouvex, 80 x 80 with 5.5 kw electric motor. Located at groundfloor of powerhouse. Located at ground floor of powerhouse.

20. HFO Day Tank Heaters-6 unit 1977. Fryer and Cie, steam 8VA. 100,000 kcal/hr. cap., with thermostaticcontrol. Located at ground floor of powerhouse.

21. HFO Centrifugal Separator-3 unit 1977. Alfa Laval, Type MAPX313TGT-24-60, 6,500 liters/hr. capacity,complete with motor, pipes, valves and control panels. Located atground floor of powerhouse.

22 HFO Feed Pump (Motor/Pump)01 unit 1977 .5.5 kw electric motor, 240/460 volts. Located at basement of powerhouse.

23. LFO Feed Pump-2 unit 1977. Mouvex, ALHP, with CEM electric motor, type MEUV, 5.5 kw, 1715rpm, 460 volts, 60 Hz. (for unit 1 and unit 6). Located at groundfloor of powerhouse.

24. Fabricated Sludge Tank-1 PC 1977

MISCELLANEOUS POWER PLANT EQUIPMENT

1. Fire Protection Equipment 1 lot 1980. Consisting of: Fire Pump - Vertical type, 5678 liters per minute capacity, driven thru gear reducer by: 6-cylinder Diesel Engine Cummins, Model MT-835-P. Engine No. 10922706, complete with fuel day tank and controls with 6 fire hydrants, only 5 units with box and fire hose and other accessories. (plant compound) Standby Pump . turbine type, 5678 liters per minute capacity, driven by: 149 kw Electric Motor . General Electric, Model 5K6278XH1A, with motor controller panel. Foam Generating SystemConsisting of: Foam Tank - 22,000 liters capacity, mild steel plate welded construction, 1372 mm. dia.x 2388 mm. long outside dimensions. Foam Pump - Viking Pump, USA,

Page 10: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

Model 1(1<124, 189 liters/mm. capacity, driven by: 7.5 kw Electric Motor Westinghouse, 1745 rpm, 3-phase, 60-cycle, system complete with control piping connectors and other necessary accessories for normal operations with 4 fire hydrants only 2 units with box and fire hose and other accessories. (tank farm)

2. Overhead Traveling Crane 1 unit 1977. Socomeg Verlinde, 50/5 ton main auxiliary lifting capacity, double bridge, complete with hoist, drive and motor accessories. Located at powerhouse.

3. Overhead Travelling Crane-1 unit 1977. Demag, 50/5 ton main/auxiliary lifting capacity, double bridge,complete with hoist, drive and motor accessories. Located at powerhouse.

4. Jacket Cooling Water Tank-6 unit 1977, M.S. tank, 1,000 liters capacity. Located at roof deck of powerhouse.

5 . Injector Cooling Water Tank-6 unit 1977. Mild steel tank, 500 liter capacity, 558 x 1295 mm DL. Located at roof deck of powerhouse.

6. Jacket Cooling Water Tank-1 unit 1975. 500 titers capacity. Mild steel plate material of welded construction. Located at 1 2PC2.5 powerhouse.

7. Air Compressor Tank Receiver-1 unit 1975. Chaudronnerie Soudee Moderni, 1,000 liters capacity, 45 bars working pressure. Located at ground floor of powerhouse, 12PC2.5.

8. Jacket Cooling Water Pumps-12 unit 1977. Jeumont Schneider, Type ME200355, 600 cu.m./hr. capacity, each driven by: 90 kw Electric Motor - Type FtIC.280-M4-B3, 460 volts, 3- phase, 60-cycle complete with inlet and discharge valves. Located at ground floor of powerhouse.

9. Dirty Oil Tank-1 unit 1977. Horizontal mild steel tank, 50 KL capacity. approx. 2500 x 5000 mm DL. with catwalk platform, saddle concrete foundation. Located at sump pit area of powerhouse.

10. Condensate Tank-1 unit 1977. Horizontal mild steel tank. approx. 1800 mm. dia. x 4000 mm. long, with insulation, safety relief valves, steam traps, pipings and on concrete craddles foundation. Located at sump pit area of powerhouse.

11. Condensate Lift Pump-2 unit 1985. Vertical and horizontal pattern 50 x 50 connections and electric motor. Located at sump pit area of powerhouse.

12. Condensate Tank-3 unit 1985. Fabricated mild steel tank, approx. 2.44 x 2.4 x 1,22m, 2.28 x 1.56 x 1.63m and 2.45 x 1.22 x 1.23m LWH. Located at the back of

powerhouse.

13. Separator Sealing Water System 1 set 1977 0.0037% M.S. header tank with two (2) small pumps. Located at ground floor of powerhouse.

Page 11: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

14. Exhaust Gas Boilers-2 unit 1977. Air Industries, steel fabricated, approx. 1800 x 3300 mm DL, 5.5 tons/hr. steam cap., 7 bar pressure, with thermostatic control and capillary tube and other accessories. Located at roof deck of powerhouse.

15. Recycled Oil Pump-1 unit 1977. Leroy Somer, driven by 3kw electric motor. Located at the back of powerhouse, 12PC2.5.

16. Steam Drum-1 unit 1977. Air Industrie, steel insulated type, approx. 2000 x 6096 mm. DL, 17,500 titers cap., 13 bars hydrostatic. 6 bars working pressure, 7 bars design, unit complete with steam header, 305 x 3835 mm DL, safety valves, temperature gauges, pipings, catwalk platform, fittings and accessories. Located at roof deck of powerhouse.

17. Lube Oil Pumps (for Fuel Recovery Plant)-2 unit 1975. Pompes Guinard, Type SZS94O.42G, 110 cu.m./hr. capacity, driven by: 44.4 kw Electric Motor, Leroy Somer, Type LSN225S5 and 30 kW electric motor, Leroy Somer, type LSN200L7. Located at tank farm.

18. Rocker Gear Lube Oil Pump 1 unit 1975. Balmo type, B2/24H, 30m bars working pressure driven by 0.55 kw electric motor, 1750 rpm

19. Air to Air Radiators (Cooling System)1 lot 1975. Chausson type 50221811, structural steel frame support bolted on concrete floor, each with six (6) modules, 5.5 kw CEM electric fan motor, 460V, 3 ph, 60 Hz, complete with pipes. Located radiator area.

20. Lube Oil Radiator (12PC2.5)-1 lot 1977. 6 modules (frame only). Located radiator area, 12PC2.5.

21. Lube Oil Circulating Pumps-12 unit 1977. Hamworthy, Type #36860-3, 400 cu.m./hr. capacity,each driven by 90 kw Electric Motor - Brook Crompton Parkinson Motors, Frame D315S, 3-phase, 60-cycle, 460 volts. Located at ground floor of powerhouse.

22. Lube Oil Feed Pumps-12 unit 1977. Hamworthy, Type #36357-4, 400 cu.m./hr. capacity, each driven by: 150 kw Electric Motor - Brook Crornpton Parkinson Motors, Frame D315S, 3-phase, 60-cycle, 460 volts. Located at ground floor of powerhouse.

23. Lube Oil Filter 10 set 1977. Moatti Filters, Type GM 30/12, 120 cu.m./hr. cap., 38 liter volume, steel 305 x 813 mm DH, at 76 mm suction and discharged pipe, (2 per set). Located at ground floor of powerhouse.

24. Rocker Arm Lubricating Units6 et 1977. Balmo. gear type, Type BML 3/40-R, 8 bars cap., each with 1.1 kw, 1710 rpm, 460 volts, 3 ph, with lubricating tanks, 991 x 648 x 535 mm LWH and other accessories. Located at ground floor of powerhouse.

25. Smoke Stack (18PC4)-6 PC 1977. 182 cm dia at lower portion and 120 cm dia upper portion, with a height of 930 cm, mounted on concrete foundation. Located at roof deck of powerhouse.

Page 12: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

26. Smoke Stack (12PC2.5)-4 PC 1977. 457 cm dia at lower portion and 213.5 cm dia upper portion, 1 cm thick, with a height of 971 cm. Located at roof deck of powerhouse.

27. Lube Oil Centrifugal Heater-6 unit 1977. Fryer and Cie, Steam 5VA, 90,000 Kcal/hr. cap.. with thermostatic control. Located at ground floor of powerhouse.

28. Aerocoridenser-4 unit 1977. Serick, type DM6504-01-61, 8,763 kcal/hr cap., air cooledcondenser, each with cooling fan 13.2 kw motor, 460 volts, 3 ph,60 Hz. Located at radiator area.

29. Air to Air Radiator Modules -6 unit 1977. Chausson, France, Type HV180-6-13/1-7400152!4, 1,600,000kcal/hr. capacity, each with 10 modules. 10 motors and otheraccessories. Located at radiator area.

30. Lube Oil Radiators -6 unit 1977. Chausson, France, Type l-IV 180-6.13/1.7400152/4. 1,600.000kcal/hr. capacity, each with 6 modules, 6 motors and otheraccessories. Located at radiator area.

31. Jacket Water Radiators-6 unit 1977. Chausson, France, Type HV18O-6-13/1-74-00152/4, 1,600.000kcal/hr. capacity, each with four (4) modules and four (4) drivemotors and other accessories. Located at radiator area.

32 Lube Oil Storage Tank-2 unit 1977. Horizontal, mild steel tank, approx. 2500 X 7000 mm. DL, on steelcraddles with concrete foundation. Located at left side ofpowerhouse.

33. Lube Oil Storage Tank (Cattex)-1unit. Horizontal, M.S. approx 2.43m dia x 5m tong on cradles. Located atleft side of powerhouse.

34. Lube Oil Transfer Pumps-2 unit 1977. Hamworthy, type 440L2, 25 cu.m./hr cap. Located at sump pitarea of powerhouse.

35. Lube Oil Transfer Pumps. 1 unit 1977. Hamworthy, type 440L2, 25 cu.m./hr cap. Located at sump pitarea of powerhouse.

36. Lube Oil Transfer Pump-6 unit 1977.Blackmer, Model TNP2, 50x50 mm SD, belt driven by 5HP motor,460V, 3-phase, 60 Hz, model 49g3a, type-UT with pressure switch.Located at back of powerhouse.

37. Lube Oil Sump Tanks-6 unit 1977.Mild steel plate material of welded construction, 30 KL. Located atground floor of powerhouse.

38. Lube Oil Centrifugal Separator-2 unit1977. Alfa Laval, Type MAB-2095-24-60/40. 5,500 liters/hr cap., eachdriven by 11 kw Electric Motor - CEM, Type #JUL16OL4, 3-phase,60-cycle, 460 volts and other accessories. Located at ground floorof powerhouse.

39. Steam Circulating Pumps Jeumont Schneider, pump with CEM electric motor - 6.25 kW anc11 kW, 1730 rpm and 1760 rpm, respectively, 460V, 3 phase, 60 Hz,complete with pipings and valves. Located at 2nd floor ofpowerhouse.

Page 13: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

40 Air Fitters-6 unit 1977. Delbag, rotary air fitters with washing installation and sludges remover, size 207/14, A & B bank. Located at ground floor of powerhouse.

41. Injector Cooling Water Pump-6 unit 1977. Jeumont Schneider, type 5OFV6L, 6.0 cu.ml/hr cap., each driven by 1.9kW electric motor type HEUB9OLL4. 3-phase, 60 cycle, 460 volts, 2 sets per unit. Located at ground floor of powerhouse.

42. Air Compressor-1 unit 1977. Ingersol Rand, Type 30, Model 15T2, Series 22168, 2-stage, driven by: 20 kw Electric Motor - General Electric, 3-phase, 60-cycle, 460 volts. Located at ground floor of powerhouse.

43. Air Receiver 2 set 1977.Chaudronnerie de Atlantique, two (2)-9000 liters capacity, and two (21-2000 liters capacity, with pressure regulators. Located atground floor of powerhouse.

44. Jacket Water Radiator (12PC2.5)-1 set 1975. Frame only. Located at right side of powerhouse, 12PC2,S,

45. Treated Water Transfer Pump. 1 unit 1975. Jeumont Schneider, Type SOP, 4 cu.m./hr. capacity, each with 1.9kw drive motor complete with pipes and valves. Located at the back of powerhouse, 12PC2.5.

46. Treated Water Tanks-2 unit 1977. 3500 liters capacity, mild steel plate welded construction. 2000 mnm. dia, x 2052 mm. high outside dimension. Located at the back of powerhouse, 1 2PC2.5.

47. Treated Water Tank-1 unit 1992. Fiberglass (Spherical Tank) with pipings. Located at the back of powerhouse, 1 2PC2.5.

48. Water Treatment (Water Softener)-1 unit 1980. 1219 x 1828 mm DH complete with one (1) resin tank Steel 508mm x 2184mm DH, one (1) water pump - Grundfos, type .J57, 25 x 13 mm SD, unit complete with pipings, fittings, 3-way valve and electrical control. Located at the back of laboratory building.

49. Dewatering Pump-1 unit 1977. Compton Parkinson, M. C. No, F-0254-1592. 10 HP, 1730 rpm, 440 Volts, 14,54, 60 Hz, Class - E. Located at the sump pit area ofpowerhouse.

50. Submersible Pump-1 unit 1977. Jeumont Schneider, driven by 5.5 kW electric motor, 460 volts, Located at the sump pit area of powerhouse,

51. Dewatering Pump-1 unit 1977 0.0029%Mouvex type, driven by 5.5kW electric motor, 460 volts. Located at tank farm.

52. Oil / Water Separator Pump-1 unit 1977. Mouvex type, driven by 8.5kW electric motor. 460 volts. Located attank farm.

53. Treated Water Storage I Make-up Pump-2 unit 1977. Jeumont Schneider, type MEN, 125-250 cu.m/hr cap., driven by 7.5kW electric motor, 460 volts. One unit without motor. Located atthe sump pit area of powerhouse.

Page 14: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

54. Air Inlet Duct-12 PC 1977. Made of GI sheet with total length of 1,600 cm and 100 cm indiameter. Located at the 3'd floor of powerhouse.

STATION SERVICE EQUIPMENT

1. 15kV Metal Clad Switchgear-1 unit 2004. Merlin Germ, outdoor type, consisting of sepan 1000 (include:meters, 3 sets potential xformer, heater, lamp, and fuse 3 sets)1.2 x 2.4 x 2.7 m dimension. Located at transformer area.

2, Transformer-3 unit. France Transfo., ZMVA, unit rating 13.8 kv-480 volts, 3 phase, SN32026; with PCB's. Located at transformer area.

3. Station Service Transformer -1PC 1977. France Transfo. 1200 kva, 13.8 kv/480 volts, 3 phase, completewith accessories: with PCB's. Located at the back of power house.

4. Distribution Transformer-PHELIC, 5OkVA, 480/240 volts, oil-immersed, outdoor type(Transformer Area).

5. Distribution TransformerC-A Transformer, dry-type, 37.5kVA, 480/240V. Located at groundfloor of power house.

6. 138kV Steel Tower- 1 unit 1977. Steel-framed tower structure erected on concrete foundation, withsome lengths of two (2) sets of three (3) phase ACSR cables strung on tower with high tension insulators anchored on powerhouse overhead wall at one end, and disconnected cables from Apayla S/S on the other end. Located at plant compound.

7. Main Switch-7 unit 1977. 3 phase, 3 poles, 220v for powerhouse lighting and convenience system. Located at electrical room, ground floor of powerhouse.

8. Safety Switches-3 unit 1977. Timco, 200 amp. 3 poles, 3 phase, 250/600 Vac and otheraccessories. Located at electrical room, ground floor ofpowerhouse.-

9. Panelboards 1 unit 1977. Consists of: Panel 1 - Main breaker: 200 amps, 3 ph, 3 poles, 220"with 8 branches; Panel 2 - Main Breaker: l50amps, 3 ph, 3 poles,220v with 9 branches; and Panel 3- Main Breaker: l25amps, 3 ph,3 poles. 220v with 9 branches and other accessories. Located atelectrical room, ground floor of powerhouse.

10. 15 KV Metal Clad Cubicle, 2 MVA-1 unit 1977. 3 phase switchgear without oil-circuit breaker Located at 2 floorof powerhouse.

11 Safety Switch-1 lot 1977. Consists of: (1) 2 units of 200 amps, 3 phase, 220v safety switch,Timco in brand: (2) 1 unit of 100 amps, 1 phase, 2 poles, 220venclosed circuit breaker; (3) 1 unit of panelboard, 220v with 11branches; (4) 1 unit of 250 amps, 3 phase. 220v safetyswitch,Timco in brand; and (5) 1 unit of 100 amps, 1 phase, 2poles, 220v enclosed circuit breaker and other accessories. Locatedat transformer area, housing site.

Page 15: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

12. Panetboards-3 unit 1977. Consist of 3 panel boards with 3 ph, 3 poles, 220v main breaker.Located at powerhouse.

13. Safety Switch -1 unit 1977. One (1) 220 v, 3 phase, 3 pole complete with fuse. Located atmachine shop.

14. Station Transformer-1unit 1978.0.081°- France Transfo, 630kVA, 138/480 volts complete with accessories;with PCB's. Located at the back of powerhouse.

Page 16: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

Status Of units Prior to Retirement

YEAS RETIED: January 1998 (Confirmed by NP Board)

UNIT NO. 1 OPERATIONALRunning Hours: 30,454.8

UNIT NO. 2 UNOPERATIONALConnecting Rod bearing shell seizure (B2) Fe. 26, 1993Running Hours: 22,961.5

UNIT NO. 3 OPERATIONALRunning Hours: 30,687.4

UNIT NO. 4 UNOPERATIONALBearing seizure on Connecting Rod journal No. 1-May 1995. Completed

grinding and polishing May 24, 1996. Test Run not conducted due to low insulation resistance of 440 bus bars.

Running Hours: 15,550.9UNIT NO. 6 OPERATIONAL

Engine and Generator Control Panel transferred to AGUS 2 HEPRunning Hours: 25,1660.0

DIESEL POWER PLANT UNITS STATUS As of DEC 31, 1995

UN1 T RATED CAPACITY

FIRM CAPABILITY

STATUS REMARKS

Pielstick 18PC4U No.1

19.2Mw 13Mw Operational. On economy shutdown

Pielstick 18PC4U No.2

19.2Mw 13Mw Shut down for regrinding of Crankshaft Journal. (Accomplished 60%)

Insurance of Notice to proceed was deferred upon instruction of Regional Management. Estimated target completion will be revised when temp. deferment is lifted.

Pielstick 18PC4U No.3

19.2Mw 13Mw Operational. On economy shutdown

Pielstick 18PC4U No.4

19.2Mw 13Mw Shutdown for polishing of crankpin No. 1 and metal etching of engine frame crack. (87% accomplished)

Metal etching of engine frame crack complete. Insurance notice to proceed for grinding held in obeyance per instruction of regional mngt, For revision of target upon lifting of temporarily deferment for grinding.

Pielstick 18PC4U No.5

19.2Mw 13Mw Operational on economy

Page 17: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l

shutdown.

Actual Performance for Period: Jan-Dec 1995

Performance Indicator

Wt. %

1995 Target

Actual YT (Previous Months)

Actual YTD

Adjectival Rating

Eqiv. Points

WT. Points

1.EQUIV. AVAIL FACTORS %

25 28.21 33.97 35.37 O 10 2.5

2. FORCED OUTAGE RATE %

25 7.00 10.63 10.54 F 4 1.0

3.NET HEAT RATE, BTU/KWH

25 10,728.00

9,442.16 9,452.02 O 10 2.5

4.GENERAL EFFICIENCY %

15 92.92 93.18 93.17 VS 8 1.2

5.GENERAL COST, P/KWH

10 2.25 1.40 2.45 O 10 1.0

TOTAL 100 8.2

NOTE:

Performance rating Wtd. PointsOutstanding >8.4Very satisfactory 6.82-8.40Satisfactory 5.21-6.80Fair 3.61-5.20Unsatisfactory <3.60

Page 18: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l
Page 19: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l
Page 20: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l
Page 21: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l
Page 22: Status Of units Prior to Retirement - Gas turbinecfaspower.com/GTG_1400OM_P18PC4_60Hz.doc · Web view15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l