Operation: Network configuration
Operation: Network configuration
Contents
1 Applicable Version 3
2 Basic Construct 4
2.1 SV (Supervisory) 4
2.2 DCC Termination 6
3 Protocol Stack 7
3.1 LAN 8
3.2 DCC 9
4 Network Layer 10
4.1 SNMP 11
5 Additional Function 12
6 Supported PM 13
6.1 Network Setting 1 14
6.1.1 Edit Network (Setting Network) 15
6.2 Network Setting 2 17
6.2.1 Edit Network setting 2 (Setting Network) 24
6.3 DCC Selector Setting 23
6.3.1 Edit DCC Selector Setting (Setting DCC Applications) 24
FT4232-01SMay 2008© 2008 Nokia Siemens Networks
1
Operation: Network configuration
FT4232-01SMay 2008
© 2008 Nokia Siemens Networks
2
Operation: Network configuration
1 Applicable Version
Fig. 1 Applicable Version
This document describes protocol stack and network parameters for NMS (Network Management System) implemented in an SV (Supervisory) card which is a main controller for an NE (Network Element) of SRT 1F series digital microwave radio equipment. The document also shows all NMS management objects supported by SNMP (Simple Network Management Protocol) and/or SRT1F Web LT (Web based Local craft Terminal for SRT1F) on the NE.
A person who refers this document for NMS design and SRT 1F operation, should be familiar with SRT 1F, a PC (Personal Computer), an operating system, an application software usage on the PC and basic of IP (Internet Protocol) network.
Table shows applicable version of SV hardware and firmware for this document.
SV Hardware Version TA22779-B30X
TA22779-B40X
LOG M Firmware Version V06L01RXX (V6.1)
V06L04RXX (V6.4)
MIB file Version V4.0x
This manual is valid from SRT 1F SVR 4.2.0.
FT4232-01SMay 2008© 2008 Nokia Siemens Networks
3
Operation: Network configuration
2 Basic Construct
2.1 SV (Supervisory)
Fig. 2 SV (Supervisory)
SRT1F NE
IP address
Ethernet connection
Em
bedd
ed
Web serverSNMP agent
Network management Interface
SNMP-SV unit
DCC connection
NMS of SRT 1F is designed on SNMP and HTTP (Hyper Text Transfer Protocol). SV card, main controller installed in the SRT 1F, is composed both an SNMP embedded agent and a web server. These facilities provide integrated NMS environment among SRT 1F and various type of equipment such as MUX, ADM, routers and another vender’s radio equipment thanks to SNMP, and good accessibility by HTTP which is not depend on management platform. SV card has two (2) Ethernet port and two (2) DCC (Data Communication Channel) terminations from radio/line sides as a connection port for NMS.
Figure shows block diagram of the NMS facilities on the SV card.
FT4232-01SMay 2008
© 2008 Nokia Siemens Networks
4
Operation: Network configuration
Fig. 3 Role of the SNMP agent and the web serve
Interconnectivity between Ethernet LAN connection and DCC line is realized by on-board HUB function on the SV. All of the NMS connection port, two (2) Ethernet LAN and two (2) DCCs are connected each other via the HUB. This HUB is a simple repeater HUB, so that packet routing function of any protocol layer is NOT supported by SRT 1F.
As a basic concept, NMS of SRT 1F is designed that SRT1F Web LT and SNMP are split up the equipment management work. SRT1F Web LT has full operational function such as configuration, control and performance monitoring, and is used for a main human machine interface for operation, maintenance and system setup. SNMP mainly provides an open interface for fault management and performance monitoring to a central equipment management system.
Table shows a role of the embedded SNMP agent and the SRT1F Web LT on the SV.
SRT1F WebLT (HTTP) SNMP
NE Configuration O Some basic items can be retrieved
NE Control O --
NE Condition List(Alarm Information)
O O
NE Performance Monitoring
Current History (24 hours)
CurrentHistory (4 hours)
NE Logs(Alarm History, etc.)
O --
FT4232-01SMay 2008© 2008 Nokia Siemens Networks
5
Operation: Network configuration
2.2 DCC Termination
Fig. 4 Schematic of DCC termination by SV
SV
LAN
GP1-W1-RS-RADIO
GP1-W1-MS-RADIO
GP1-W1-RS-LINE
GP1-W1-MS-LINEHUB
LAN
Controller
GP2-W1-RS-LINE
HUBGP2-W1-MS-LINE
SV
LANController
LANGP1-W1-RS-LINE
GP1-W1-MS-LINE GP1-W1-MS-RADIO
GP2-W1-RS-RADIO
GP2-W1-MS-RADIO
GP1-W1-RS-RADIO
HUB
SV for GP1
SV for GP1 GP2
The SV terminates a DCC by using W1 (Work1) channel. DCCM (D4-D12) and DCCR (D1-D3) is selectable in "MS" mode setting and only DCCR (D1-D3) for "RS" mode setting.
Figure shows schematic of DCC termination by SV.
FT4232-01SMay 2008
© 2008 Nokia Siemens Networks
6
Operation: Network configuration
3 Protocol Stack
Fig. 5 Protocol Stack
SRT 1F can use two (2) types of communication line, Ethernet LAN (Local Area Network) and DCC carried by STM1 (Synchronous Transfer Module level 1) SOH (Section Overhead) for NMS connection.Figure shows block diagram of the NMS facilities on the SV card.
FT4232-01SMay 2008© 2008 Nokia Siemens Networks
7
Operation: Network configuration
3.1 LAN
Fig. 6 Ethernet LAN Stack
Table shows protocol stack which is used on Ethernet LAN of NMS connection. SRT 1F uses two (2) type of application layer protocol. HTTP on TCP/IP is used for a web based connection between the built in web server and a client PC. SNMP on UDP/IP is used for connection between the embedded SNMP agent and SNMP managers.
Application HTTP SNMP
Transport TCP UDP
Internet IP
Network CSMA/CD
Ether
FT4232-01SMay 2008
© 2008 Nokia Siemens Networks
8
Operation: Network configuration
3.2 DCC
Fig. 7 DCC Stack
Table shows shows protocol stack which is used on DCC connection of SRT 1F NMS connection. Two (2) types of connection, HTTP on TCP/IP and SNMP on UDP/IP same as Ethernet LAN connection are also used on DCC connection carried by STM1 SOH.
Application HTTP SNMP
Transport TCP UDP
Internet IP
Network HDLC
DCC
FT4232-01SMay 2008© 2008 Nokia Siemens Networks
9
Operation: Network configuration
1
4 Network Layer
Fig. 8 Parameters of Network layer
Table shows parameters of Network layer protocol on Ethernet LAN connection. The LAN connection port on the equipment is designed based on IEEE Recommendations. The LAN port supports both connection speed of 10Base-T and 100Base-TX. Connection speed is automatically detected and negotiated with a connected equipment. For a physical cable connection to an external LAN equipment, straight and cross cable can be use without care. SRT 1F automatically detects the plugged cable type.
Parameter Value Configurable
Recommendation IEEE 802.3 (Ether) --
IEEE 802.3 (CSMA/CD) --
IEEE 802.2 (LLC Type1) --
Port 10/100Base-T/TX --
Auto negotiation No
HP Auto-MDIX No
128KB packet buffer No
Connector RJ-45 --
FT4232-01SMay 2008
© 2008 Nokia Siemens Networks
0
Operation: Network configuration
4.1 SNMP
Fig. 9 Parameters of SNMP
Table shows parameters of SNMP on Application layer. SNMP is mainly used for connection between the embedded SNMP agent and SNMP managers that is a central performance and fault management system. SNPM uses UDP/IP as a low layer protocol for connection.
SRT 1F can communicate with maximum three (3) managers. Access from the managers are controlled by an IP address and a community name. They can set independently for each manager.
Parameter Value Configurable
Protocol SNMP v2 --
Embedded Agent --
Port 161 (Listen) No
162 (Target)
Manager Max 3 manager Yes
Access Control 1
1 SRT 1F checks the IP address and the community name in the received GET Request mes-sage. If the IP address differs from pre-set one to the NE, the received message is discarded and no message is responded to the manager. If the IP address is correct but the community name differs, SRT 1F sends authentication Failure trap message to the manager.
IP Address andCommunity name 2
2 Maximum length of Community name is limited to sixteen (16) characters. If exceeded, au-thentication Failure will be responded.
Yes
Max. Receive Data Size
3000 Byte No
Recommended Manager (Test environment)
HP OpenView --
FT4232-01SMay 2008© 2008 Nokia Siemens Networks
11
Operation: Network configuration
1
5 Additional Function
Fig. 10 Summary of additional functions
In addition, SRT 1F has an SNTP client. Real time clock in an NE can be synchronized periodically to an NTP server clock built in an NMS network. This facility provide that all NEs in the NMS network can be synchronized in one clock if necessary.
SRT 1F can responds to a Ping command. This will be very useful for health check and trouble shooting of an equipment and a network.
DNS (Domain Name Service) is not supported. A target SNMP manager and an NTP server must be set by IP address.
Table shows summary of additional functions.
Parameter Value Configurable
SNTP Embedded Client --
Port 123 No
Routing No (HUB) --
Ping No --
Ping response Yes --
DNS No
FT4232-01SMay 2008
© 2008 Nokia Siemens Networks
2
Operation: Network configuration
6 Supported PM
Fig. 11 Number of performance monitoring registers
SRT 1F provides performance monitor based on ITU-T Recommendation. SRT 1F stores one (1) current and historical registers for 1-Day periodical performance, and one (1) current and ninety five (95) registers for 15-Min periodical performance. These values can be retrieved via SRT1F Web LT and SNMP.
Table shows number of performance monitoring register.
Register 1
1 Maximum PM Register Number on SV1-Day : 1 x Current + 1 x History15-Min : 1 x Current + 96 x Histories
SNMP SRT1F WebLT Index
1-Day Current 1 1 1
History 1 1 2
15-Min Current 1 1 1
History 16 2
2 Latest 16 registers (= 4 hours) can be retrieved by SNMP Get message. (Index=2 to 17)
96 2-97
FT4232-01SMay 2008© 2008 Nokia Siemens Networks
13
Operation: Network configuration
1
6.1 Network Setting 1
Fig. 12 Network Setting Main Frame
The Network Setting menu allows a user to view and modify the network parameters of the NE (Network Element).
To open the Network Setting main frame:
– Click the Provisioning Menu link in the Provisioning part of the menu frame, then the Provisioning Menu main frame will appear.
– Click the Network Setting link in the Provisioning Menu main frame, then the Network Setting subwindow will appear.
Reload Button:
Click to refresh the status of displayed main frame.
Provisioning Menu Button:
Click to return to the Provisioning Menu main frame.
Edit Network Setting 1 Button:
Click to open the Edit Network subwindow used to set the network parameters.
FT4232-01SMay 2008
© 2008 Nokia Siemens Networks
4
Operation: Network configuration
6.1.1 Edit Network (Setting Network)
Fig. 13 Edit Network Setting 1 Subwindow for Network Setting
This menu sets the parameters required for the operation of the network.
To set the parameters for the network:
– Click the Edit Network button in the Network Setting main frame, then the Edit Network subwindow will appear.
FT4232-01SMay 2008© 2008 Nokia Siemens Networks
15
Operation: Network configuration
1
Fig. 14 Edit Network (Setting Network)
Item New
Fill in the text boxes with the required contents or select the item in the New column.
Current status of the network parameters is displayed in the Current column.
IP
Set the IP (Internet Protocol) address of the NE (Network Element) in dotted decimal notation.
(Default) 192.168.0.10
Sub Netmask
Set Sub Netmask for the network in dotted decimal notation.
(Default) 255.255.255.0
Gate Way
Set the IP address of the default Gateway for the network in dotted decimal notation.
(Default) 192.168.0.1
Operate Button : Execute the command. (Clicking the button, confirmation subwindow “Configuration will be changed. OK?” will follow.)
Cancel Button : Cancel the operation.
FT4232-01SMay 2008
© 2008 Nokia Siemens Networks
6
Operation: Network configuration
6.2 Network Setting 2
Fig. 15 Network Setting Main Frame
The Network Setting menu allows a user to view and modify the network parameters of the NE (Network Element).
To open the Network Setting main frame:
– Click the Provisioning Menu link in the Provisioning part of the menu frame, then the Provisioning Menu main frame will appear.
– Click the Network Setting link in the Provisioning Menu main frame, then the Network Setting subwindow will appear.
FT4232-01SMay 2008© 2008 Nokia Siemens Networks
17
Operation: Network configuration
1
Fig. 16 Network Setting Main Frame
Reload Button:
Click to refresh the status of displayed main frame.
Provisioning Menu Button:
Click to return to the Provisioning Menu main frame.
Edit Network Setting 2 Button:
Click to open the Edit Network subwindow used to set the network parameters.
FT4232-01SMay 2008
© 2008 Nokia Siemens Networks
8
Operation: Network configuration
6.2.1 Edit Network setting 2 (Setting Network)
Fig. 17 Edit Network Setting 2 Subwindow for Network Setting
This menu sets the parameters required for the operation of the network.
To set the parameters for the network:
– Click the Edit Network button in the Network Setting main frame, then the Edit Network subwindow will appear.
FT4232-01SMay 2008© 2008 Nokia Siemens Networks
19
Operation: Network configuration
2
Fig. 18 Edit Network Setting 2 Subwindow for Network Setting
Item New
Fill in the text boxes with the required contents or select the item in the New column.
Current status of the network parameters is displayed in the Current column.
SNMP Manager #1/SNMP Manager #2/SNMP Manager #3
Set the IP address of the static SNMP (Simple Network Management Protocol) manager in dotted decimal notation. The NE communicates only with the registered SNMP manager. Maximum three managers can be registered.
Set “0.0.0.0” to the IP address for an unused manager.
(Default) : 0.0.0.0 (Function of SNMP manager is disa-bled.)
#1 Community Name/#2 Community Name/#3 Community Name
Set the Community Name of each SNMP manager registered in the NE. Either “Read-Write” or “Read-Only”
Communication Name for Read-Write
Display the community name for “Read-Write”. NE sets the name to communication name of Trap-PDU, if “Read-Write” is selected as Type of Communication Name.
Communication Name for Read-Only
Display the community name for “Read-Only”. NE sets the name to communication name of Trap-PDU, if “Read-Only” is selected as Type of Communication Name.
FT4232-01SMay 2008
© 2008 Nokia Siemens Networks
0
Operation: Network configuration
Fig. 19 Edit Network Setting 2 Subwindow for Network Setting
Standard Trap
Enable : Enable SNMP Trap sending from the NE to the SNMP manager.
Disable : Disable SNMP Trap sending from the NE to the SNMP manager.
(Default) : Disable
SNTP Server Address
Set the IP address of the SNTP (Simple Network Time Protocol) server in dotted decimal notation. The SNTP server is used to ad-just the time of the NE RTC (Real Time Clock).
(Default) : 0.0.0.0 (Function of SNTP is disabled.)
SNTP Revising Time [h:m]
Set the time to access to the SNTP server in order to adjust the RTC in the NE in [hour : minute] format. This should be use 24-hour no-tation. For example, if you set [3:0], the NE will access to the SNTP server at three o’clock in the morning every day.
(Range: 0-23)
: (Range: 0-59)
(Default) : 0:0
Time Zone [h:m] (L)
Set time zone which is different from GMT (Greenwich Mean Time).
(Range: 0-13)
: (Range: 0/15/30/45)
(Default) : +0:0
Daylight Saving Time Mode
Enable : Daylight saving time mode is enabled.
Disable : Daylight saving time mode is disabled.
(Default) Disable
FT4232-01SMay 2008© 2008 Nokia Siemens Networks
21
Operation: Network configuration
2
Fig. 20 Edit Network Setting 2 Subwindow for Network Setting
DTS Start [month, day, hour]
Set time zone which is different from GMT (Greenwich Mean Time).
(Range: 0-13)
: (Range: 0/15/30/45)
(Default) : +0:0
DTS End [month, day, hour]
Set time zone which is different from GMT (Greenwich Mean Time).
(Range: 0-13)
: (Range: 0/15/30/45)
(Default) : +0:0
ECU Card
Enable : Enable the ECU card
Disable : Disable the ECU card
(Default) Disable
This item is being kept Disable.
Operate Button : Execute the command. (Clicking the button, confirmation subwindow “Configuration will be changed. OK?” will follow.)
Cancel Button : Cancel the operation.
FT4232-01SMay 2008
© 2008 Nokia Siemens Networks
2
Operation: Network configuration
6.3 DCC Selector Setting
Fig. 21 DCC Selector Setting Main Frame
DCC (Digital Communication Channel) Selector Setting menu allows a user to view and modify DCC settings of the NE (Network Element).
To open the DCC Selector Setting main frame:
– Click the Provisioning Menu link in the Provisioning part of the menu frame, then the Provisioning Menu main frame will appear.
– Click the DCC Selector Setting link in the Provisioning Menu main frame, then the DCC Selector Setting subwindow will appear.
Reload Button:
Click to refresh the status of displayed main frame.
Provisioning Menu Button:
Click to return to the Provisioning Menu main frame.
Edit DCC Selector Setting Button:
Click to open the Edit DCC Selector Setting subwindow used to set the DCC applications.
FT4232-01SMay 2008© 2008 Nokia Siemens Networks
23
Operation: Network configuration
2
6.3.1 Edit DCC Selector Setting (Setting DCC Applications)
Fig. 22 Edit DCC Selector Setting Subwindow
This menu sets the applications regarding DCC.
To set the DCC applications:
– Click the Edit DCC Selector Setting button in the DCC Selector Setting main frame, then the Edit DCC Selector Setting subwin-dow will appear.
FT4232-01SMay 2008
© 2008 Nokia Siemens Networks
4
Operation: Network configuration
Fig. 23 Edit DCC Selector Setting Subwindow
AID (Access Identification)
Click the pull-down menu button to select the facility you want. (In this ap-plication only “GP1-W1” can be selected.)
(Default) : GP1-W1
Direction
Line : The NE (Network Element) applies the DCC to Line side.
Radio : The NE applies the DCC to Radio side.
(Default) : Radio
Selector
Click the pull-down menu button to select the mode of the DCC.
Through : The NE passes through the DCC signal.
RSDCC : The NE applies the DCC to the RS (Regenerative Section).
MSDCC : The NE applies the DCC to the MS (Multiplex Sec-tion).
Note*: When NE MODE is set to “MS”, RSDCC and MSDCC is selectable, but when NE MODE is set to “RS”, DCC is only RSDCC.
(Default) : Through
Operate Button : Execute the command. (Clicking the button, confirmation subwindow “Configuration will be changed. OK?” will follow.)
Cancel Button : Cancel the operation.
FT4232-01SMay 2008© 2008 Nokia Siemens Networks
25
Operation: Network configuration
2
FT4232-01SMay 2008© 2008 Nokia Siemens Networks
6