WCDMA RNC
Creating RNC2600 Hardware Configuration
DN70633411 Issue 04 Approval Date 2011-01-
DN70633411 Issue 04
2 (41)
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given “as is” and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2011. All rights reserved.
f Important notice on product safety Elevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures. Non-observance of these conditions and the safety instructions can result in personal injury or in property damage. Therefore, only trained and qualified personnel may install and maintain the system. The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply with the applicable safety standards. The same text in German: Wichtiger Hinweis zur Produktsicherheit In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Spannung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen. Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverletzungen und Sachschäden führen. Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet. Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.
DN70633411 Issue 04
3 (41)
Table of Contents
1 Overview of Creating RNC2600 Hardware Configuration........................................................................ 7
2 Equipping Hardware to the Database for RNC2600 Capacity Steps 1-3 ............................................................. 10
2.1 Equipping RNAC Basic Cabinet for RNC2600..................... 10 2.1.1 Create RNAC Basic Cabinet................................................ 10 2.1.2 Create Subracks to RNAC Basic Cabinet............................ 10 2.1.3 Create Plug-in Units to Subrack 1 in RNAC Basic Cabinet . 11 2.1.4 Create Plug-in Units to Subrack 2 in RNAC Basic Cabinet . 12 2.1.5 Create Plug-in Units to Subrack 3 in RNAC Basic Cabinet . 13 2.1.6 Create Plug-in Units to Subrack 4 in RNAC Basic Cabinet . 14 2.1.7 Create Connections for Subrack 1 and 2 for RNAC Basic
Cabinet................................................................................. 15 2.1.8 Crossover Connections for Subrack 1 and 2 for RNAC
Basic Cabinet ....................................................................... 16 2.1.9 Create NPS1/NPGE Connections for Subrack 1 and 2 for
RNAC Basic Cabinet............................................................ 17 2.1.10 Create Connections for Subrack 3 and 4 for RNAC Basic
Cabinet................................................................................. 17 2.1.11 Crossover Connections for Subrack 3 and 4 for RNAC
Basic Cabinet ....................................................................... 20 2.1.12 Create NPS1/NPGE Connections for Subrack 3 and 4 for
RNAC Basic Cabinet............................................................ 20 2.1.13 Create Functional Units to Subracks in RNAC Basic
Cabinet................................................................................. 22 2.2 Equipping the RNBC Extension Cabinet for RNC2600........ 26 2.2.1 Create RNBC Extension Cabinet......................................... 26 2.2.2 Create Subracks to RNBC Extension Cabinet..................... 26 2.2.3 Create Plug-in Units for Subrack 1 in RNBC Extension
Cabinet................................................................................. 27 2.2.4 Create Plug-in Units for Subrack 2 in RNBC Extension
Cabinet................................................................................. 28 2.2.5 Create Plug-in Units for Subrack 3 in RNBC Extension
Cabinet................................................................................. 29 2.2.6 Create Plug-in Units for Subrack 4 in RNBC Extension
Cabinet................................................................................. 30 2.2.7 Create Connections for Subrack 1 in RNBC Extension
Cabinet................................................................................. 31
DN70633411 Issue 04
4 (41)
2.2.8 Create Connections for Subrack 2 in RNBC Extension Cabinet................................................................................. 33
2.2.9 Create NPS1/NPGE Connections for Subrack 1 and 2 in RNBC Extension Cabinet..................................................... 34
2.2.10 Create Connections for Subrack 3 in RNBC Extension Cabinet................................................................................. 34
2.2.11 Create Connections for Subrack 4 in RNBC Extension Cabinet................................................................................. 36
2.2.12 Create NPS1/NPGE Connections for Subrack 3 and 4 in RNBC Extension Cabinet..................................................... 37
2.2.13 Create Functional Units to Subracks in RNBC Extension Cabinet................................................................................. 38
DN70633411 Issue 04
5 (41)
Summary of Changes
Changes between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.
Note that the issue numbering system has changed. For more information, see Guide to WCDMA RAN Operating Documentation.
Changes between issues 03 and 04
Figure 2 RN6.0 delivered RNC2600 capacity steps is added.
Commands for the plug-in units CCP1D_A and HDS-C are added.
All NPS1P and NPGEP are updated to NPS1(P) and NPGE(P) because NPS1 and NPGE units are also options.
In section Create Plug-in Units to Subrack 1 in RNAC Basic Cabinet:
The note of command “ZWFP:NP2GE_B,1,1,18;” is updated.
In section Create Plug-in Units to Subrack 2 in RNAC Basic Cabinet:
The note of command “ZWFP:NP2GE_B,1,2,18;” is updated.
In section Create Functional Units to Subracks in RNAC Basic Cabinet:
Commands for NPS1 and NPGE units are added.
In section Create Functional Units to Subracks in RNBC Extension Cabinet:
Commands for NPS1 and NPGE units are added.
Changes between issues 02 and 03
Content added in Create Functional Units to Subracks in RNAC Basic Cabinet and Create Functional Units to Subracks in RNBC Extension Cabinet chapters. Changes due to ICSU/DMCU restarts caused by too many consecutive ZWFU command executions in a short period of time. Corrected commands in Create Connections for Subrack 4 in RNBC Extension Cabinet chapter.
DN70633411 Issue 04
6 (41)
Changes between issues 1-0 and 02
Unit indexes and TSS notations corrected in the figure 1.
Alternative PIUs added to tables: 3, 4, 5, 6, 16, 17, 18 and 19.
Alternative functional units added to tables: 13 and 26.
DN70633411 Issue 04
7 (41)
1 Overview of Creating RNC2600 Hardware Configuration
These instructions describe the hardware creation with MML commands for the RNC2600.
You need these instructions, for example, when you create new capacity steps or add new plug-in units into the hardware database.
These instructions are valid for the following RNC2600 capacity steps:
RNC2600 capacity step 1
RNC2600 capacity step 2
RNC2600 capacity step 3
The document lists the required MML commands for creating the equipment database.
This document should be used in combination with the Hardware Expansion documentation.
For cabling and equipping specific instructions, see the documents under RNC Hardware Installation Reference and in the separate Site Documentation set.
Cabinet, subrack and plug-in unit types depend on the used hardware.
DN70633411 Issue 04
8 (41)
Figure 1 RN4.0 and RN5.0 delivered RNC2600 capacity steps
DN70633411 Issue 04
9 (41)
Figure 2 RN6.0 delivered RNC2600 capacity steps
DN70633411 Issue 04
10 (41)
2 Equipping Hardware to the Database for RNC2600 Capacity Steps 1-3
2.1 Equipping RNAC Basic Cabinet for RNC2600
2.1.1 Create RNAC Basic Cabinet
Command Notes
ZWFJ:EC216,1,1A; Create a cabinet 1 (EC-216_B)
Table 1 Create RNAC basic cabinet
2.1.2 Create Subracks to RNAC Basic Cabinet
Command Notes
ZWFC:SRA3,1,1,1A1-0; Create a subrack 1 in cabinet 1 (SRA3)
ZWFC:SRA3,1,2,1A2-0; Create a subrack 2 in cabinet 1 (SRA3)
ZWFC:SRA3,1,3,1A3-0; Create a subrack 3 in cabinet 1 (SRA3)
ZWFC:SRA3,1,4,1A4-0; Create a subrack 4 in cabinet 1 (SRA3)
Table 2 Create subracks to RNAC basic cabinet
DN70633411 Issue 04
11 (41)
2.1.3 Create Plug-in Units to Subrack 1 in RNAC Basic Cabinet
Command Notes
ZWFP:SF20H,1,1,2; Create SFU-0
ZWFP:<piu type>,1,1,3; Create ICSU-0.
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,1,1,4; Create RSMU-0
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:MCP18_B,1,1,6; Create OMS, only when CCP1D-A is not used as OMU and HDS-C is not used as WDU
ZWFP:CDSP_DH,1,1,7; Create DMCU-0
ZWFP:CDSP_DH,1,1,8; Create DMCU-1
ZWFP:MX1G6_A,1,1,9; Create MXU-0
ZWFP:PD30,1,1,10; Create PD30
ZWFP:MX1G6_A,1,1,11; Create MXU-1
ZWFP:CDSP_DH,1,1,12; Create DMCU-2
ZWFP:CDSP_DH,1,1,13; Create DMCU-3
ZWFP:<piu type>,1,1,14; Plug-in unit type is
HDS_B (HDD-0&WDU-0) when CCP18-A is used as OMU
or
HDS_C (WDU-0) when CCP1D-A is used as OMU
ZWFP:<piu type>,1,1,16; Create OMU-0
Plug-in unit type is CCP18_A or CCP1D_A
ZWFP:NP8S1_B,1,1,17;
or
ZWFP:NP2GE_B,1,1,17;
Create NPS1(P)-0/NPGE(P)-0
ZWFP:NP2GE_B,1,1,18; Create NPGE(P)-2 only if NP8S1_B is not created to 1,1,17
ZWFP:TSS3_A,1,1,19; Create TSS3
ZWFP:TBUF,1,1,38; Create TBUF
Table 3 Create plug-in units to subrack 1 in RNAC basic cabinet
DN70633411 Issue 04
12 (41)
2.1.4 Create Plug-in Units to Subrack 2 in RNAC Basic Cabinet
Command Notes
ZWFP:SF20H,1,2,2; Create SFU-1
ZWFP:<piu type>,1,2,3; Create ICSU-1
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,1,2,4; Create RSMU-1
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,1,2,6; Create ICSU-2
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:CDSP_DH,1,2,7; Create DMCU-4
ZWFP:CDSP_DH,1,2,8; Create DMCU-5
ZWFP:MX1G6_A,1,2,9; Create MXU-2
ZWFP:PD30,1,2,10; Create PD30
ZWFP:MX1G6_A,1,2,11; Create MXU,3
ZWFP:CDSP_DH,1,2,12; Create DMCU-6
ZWFP:CDSP_DH,1,2,13; Create DMCU-7
ZWFP:<piu type>,1,2,14; Plug-in unit type is
HDS_B (HDD-1&WDU-1) when CCP18-A is used as OMU
or
HDS_C (WDU-0) when CCP1D-A is used as OMU
ZWFP:<piu type>,1,2,16; Create OMU-1
Plug-in unit type is CCP18_A or CCP1D_A
ZWFP:NP8S1_B,1,2,17;
or
ZWFP:NP2GE_B,1,2,17;
Create NPS1(P)-1/NPGE(P)-1
ZWFP:NP2GE_B,1,2,18; Create NPGE(P)-3 only if NP8S1_B is not created to 1,2,17
ZWFP:TBUF,1,2,19; Create TBUF
ZWFP:TSS3_A,1,2,38; Create TSS3
Table 4 Create plug-in units to subrack 2 in RNAC basic cabinet
DN70633411 Issue 04
13 (41)
2.1.5 Create Plug-in Units to Subrack 3 in RNAC Basic Cabinet
Command Notes
ZWFP:<piu type>,1,3,1; Create ICSU-3
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,1,3,2; Create ICSU-4
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,1,3,3; Create ICSU-5
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,1,3,4; Create ICSU-6
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:EHAT,1,3,5; Create EHU
ZWFP:CDSP_DH,1,3,6; Create DMCU-8
ZWFP:CDSP_DH,1,3,7; Create DMCU-9
ZWFP:CDSP_DH,1,3,8; Create DMCU-10
ZWFP:MX1G6_A,1,3,9; Create MXU-4
ZWFP:PD30,1,3,10; Create PD30
ZWFP:MX1G6_A,1,3,11; Create MXU-5
ZWFP:CDSP_DH,1,3,12; Create DMCU-11
ZWFP:CDSP_DH,1,3,13; Create DMCU-12
ZWFP:<piu type>,1,3,14; Create ICSU-7
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:NP8S1_B,1,3,15;
or
ZWFP:NP2GE_B,1,3,15;
Create NPS1(P)-2/NPGE(P)-4
ZWFP:NP8S1_B,1,3,17;
or
ZWFP:NP2GE_B,1,3,17;
Create NPS1(P)-4/NPGE(P)-6
ZWFP:TBUF,1,3,19; Create TBUF
ZWFP:TBUF,1,3,38; Create TBUF
Table 5 Create plug-in units to subrack 3 in RNAC basic cabinet
DN70633411 Issue 04
14 (41)
2.1.6 Create Plug-in Units to Subrack 4 in RNAC Basic Cabinet
Command Notes
ZWFP:<piu type>,1,4,1; Create ICSU-8
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,1,4,2; Create ICSU-9
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,1,4,3; Create ICSU-10
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,1,4,4; Create ICSU-11
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,1,4,5; Create ICSU-12
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:CDSP_DH,1,4,6; Create DMCU-13
ZWFP:CDSP_DH,1,4,7; Create DMCU-14
ZWFP:CDSP_DH,1,4,8; Create DMCU-15
ZWFP:MX1G6_A,1,4,9; Create MXU-6
ZWFP:PD30,1,4,10; Create PD30
ZWFP:MX1G6_A,1,4,11; Create MXU-7
ZWFP:CDSP_DH,1,4,12; Create DMCU-16
ZWFP:CDSP_DH,1,4,13; Create DMCU-17
ZWFP:<piu type>,1,4,14; Create ICSU-13
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:NP8S1_B,1,4,15;
or
ZWFP:NP2GE_B,1,4,15;
Create NPS1(P)-3/NPGE(P)-5
ZWFP:NP8S1_B,1,4,17;
or
ZWFP:NP2GE_B,1,4,17;
Create NPS1(P)-5/NPGE(P)-7
ZWFP:TBUF,1,4,19; Create TBUF
ZWFP:TBUF,1,4,38; Create TBUF
Table 6 Create plug-in units to subrack 4 in RNAC basic cabinet
DN70633411 Issue 04
15 (41)
2.1.7 Create Connections for Subrack 1 and 2 for RNAC Basic Cabinet
Command Notes
ZWFS:1,1,2,B76,1:1,1,9,B108,2; SFU-0 <-> MXU-0
ZWFS:1,1,2,B77,1:1,1,11,B108,2; SFU-0 <-> MXU-1
ZWFS:1,1,3,B76,1:1,1,9,B107,2; ICSU-0 <-> MXU-0
ZWFS:1,1,3,B77,1:1,1,11,B107,2; ICSU-0 <-> MXU-1
ZWFS:1,1,4,B76,1:1,1,9,B105,2; RSMU-0 <-> MXU-0
ZWFS:1,1,4,B77,1:1,1,11,B105,2; RSMU-0 <-> MXU-1
ZWFS:1,1,7,B76,1:1,1,9,B102,2;
ZWFS:1,1,7,B78,1:1,1,9,B118,2;
DMCU-0 <-> MXU-0
ZWFS:1,1,7,B77,1:1,1,11,B102,2;
ZWFS:1,1,7,B79,1:1,1,11,B118,2;
DMCU-0 <-> MXU-1
ZWFS:1,1,8,B76,1:1,1,9,B101,2;
ZWFS:1,1,8,B78,1:1,1,9,B116,2;
DMCU-1 <-> MXU-0
ZWFS:1,1,8,B77,1:1,1,11,B101,2;
ZWFS:1,1,8,B79,1:1,1,11,B116,2;
DMCU-1 <-> MXU-1
ZWFS:1,1,12,B76,1:1,1,9,B96,2;
ZWFS:1,1,12,B78,1:1,1,9,B115,2;
DMCU-2 <-> MXU-0
ZWFS:1,1,12,B77,1:1,1,11,B96,2;
ZWFS:1,1,12,B79,1:1,1,11,B115,2;
DMCU-2 <-> MXU-1
ZWFS:1,1,13,B76,1:1,1,9,B97,2;
ZWFS:1,1,13,B78,1:1,1,9,B114,2;
DMCU-3 <-> MXU-0
ZWFS:1,1,13,B77,1:1,1,11,B97,2;
ZWFS:1,1,13,B79,1:1,1,11,B114,2;
DMCU-3 <-> MXU-1
ZWFS:1,1,16,B76,1:1,1,9,B100,2; OMU-0 <-> MXU-0
ZWFS:1,1,16,B77,1:1,1,11,B100,2; OMU-0 <-> MXU-1
ZWFS:1,1,16,F1,0:1,1,14,F2,0; OMU-0 <-> WDU-0, only when CCP1D-A is used as OMU and HDS-C is used as WDU
ZWFS:1,2,2,B76,1:1,2,9,B108,2; SFU-1 <-> MXU-2
ZWFS:1,2,2,B77,1:1,2,11,B108,2; SFU-1 <-> MXU-3
ZWFS:1,2,3,B76,1:1,2,9,B107,2; ICSU-1 <-> MXU-2
ZWFS:1,2,3,B77,1:1,2,11,B107,2; ICSU-1 <-> MXU-3
DN70633411 Issue 04
16 (41)
ZWFS:1,2,4,B76,1:1,2,9,B105,2; RSMU-1 <-> MXU-2
ZWFS:1,2,4,B77,1:1,2,11,B105,2; RSMU-1 <-> MXU-3
ZWFS:1,2,6,B76,1:1,2,9,B103,2; ICSU-2 <-> MXU-2
ZWFS:1,2,6,B77,1:1,2,11,B103,2; ICSU-2 <-> MXU-3
ZWFS:1,2,7,B76,1:1,2,9,B102,2;
ZWFS:1,2,7,B78,1:1,2,9,B118,2;
DMCU-4 <-> MXU-2
ZWFS:1,2,7,B77,1:1,2,11,B102,2;
ZWFS:1,2,7,B79,1:1,2,11,B118,2;
DMCU-4 <-> MXU-3
ZWFS:1,2,8,B76,1:1,2,9,B101,2;
ZWFS:1,2,8,B78,1:1,2,9,B116,2;
DMCU-5 <-> MXU-2
ZWFS:1,2,8,B77,1:1,2,11,B101,2;
ZWFS:1,2,8,B79,1:1,2,11,B116,2;
DMCU-5 <-> MXU-3
ZWFS:1,2,12,B76,1:1,2,9,B96,2;
ZWFS:1,2,12,B78,1:1,2,9,B115,2;
DMCU-6 <-> MXU-2
ZWFS:1,2,12,B77,1:1,2,11,B96,2;
ZWFS:1,2,12,B79,1:1,2,11,B115,2;
DMCU-6 <-> MXU-3
ZWFS:1,2,13,B76,1:1,2,9,B97,2;
ZWFS:1,2,13,B78,1:1,2,9,B114,2;
DMCU-7 <-> MXU-2
ZWFS:1,2,13,B77,1:1,2,11,B97,2;
ZWFS:1,2,13,B79,1:1,2,11,B114,2;
DMCU-7 <-> MXU-3
ZWFS:1,2,16,B76,1:1,2,9,B100,2; OMU-1 <-> MXU-2
ZWFS:1,2,16,B77,1:1,2,11,B100,2; OMU-1 <-> MXU-3
ZWFS:1,2,16,F1,0:1,2,14,F2,0; OMU-1 <-> WDU-1, only when CCP1D-A is used as OMU and HDS-C is used as WDU
Table 7 Create connections for subrack 1 and 2 for RNAC basic cabinet
2.1.8 Crossover Connections for Subrack 1 and 2 for RNAC Basic Cabinet
Command Notes
ZWFS:1,1,2,B71D/B0,2:1,1,9,B57/B0,1; SFU-0 <-> MXU-0
ZWFS:1,1,2,B69D/B1,2:1,1,11,B57/B0,1; SFU-0 <-> MXU-1
ZWFS:1,2,2,B71D/B0,2:1,1,9,B67/B2,1; SFU-1 <-> MXU-0
DN70633411 Issue 04
17 (41)
ZWFS:1,2,2,B69D/B1,2:1,1,11,B67/B2,1; SFU-1 <-> MXU-1
ZWFS:1,1,2,B67D/B2,2:1,2,9,B57/B0,1; SFU-0 <-> MXU-2
ZWFS:1,1,2,B65D/B3,2:1,2,11,B57/B0,1; SFU-0 <-> MXU-3
ZWFS:1,2,2,B67D/B2,2:1,2,9,B67/B2,1; SFU-1 <-> MXU-2
ZWFS:1,2,2,B65D/B3,2:1,2,11,B67/B2,1; SFU-1 <-> MXU-3
ZWFS:1,1,14,F1,0:1,2,14,F1,0; WDU-0 <-> WDU-1, only when CCP1D-A is used as OMU and HDS-C is used as WDU
Table 8 Crossover connections for subrack 1 and 2 for RNAC basic cabinet
2.1.9 Create NPS1/NPGE Connections for Subrack 1 and 2 for RNAC Basic Cabinet
Command Notes
ZWFS:1,1,2,B97/B16,2:1,1,17,B103/B0,1; SFU-0 <-> NPS1(P)-0/NPGE(P)-0
ZWFS:1,1,2,B95/B17,2:1,2,17,B103/B0,1; SFU-0 <-> NPS1(P)-1/NPGE(P)-1
ZWFS:1,2,2,B97/B16,2:1,1,17,B115/B2,1; SFU-1 <-> NPS1(P)-0/NPGE(P)-0
ZWFS:1,2,2,B95/B17,2:1,2,17,B115/B2,1; SFU-1 <-> NPS1(P)-1/NPGE(P)-1
ZWFS:1,1,2,B93/B18,2:1,1,18,B103/B0,1; SFU-0 <-> NPGE(P)-2
ZWFS:1,1,2,B91/B19,2:1,2,18,B103/B0,1; SFU-0 <-> NPGE(P)-3
ZWFS:1,2,2,B93/B18,2:1,1,18,B115/B2,1; SFU-1 <-> NPGE(P)-2
ZWFS:1,2,2,B91/B19,2:1,2,18,B115/B2,1; SFU-1 <-> NPGE(P)-3
Table 9 Create NPS1(P)/NPGE(P) connections for subrack 1 and 2 for RNAC basic cabinet
2.1.10 Create Connections for Subrack 3 and 4 for RNAC Basic Cabinet
DN70633411 Issue 04
18 (41)
Command Notes
ZWFS:1,3,1,B76,1:1,3,9,B109,2; ICSU-3 <-> MXU-4
ZWFS:1,3,1,B77,1:1,3,11,B109,2; ICSU-3 <-> MXU-5
ZWFS:1,3,2,B76,1:1,3,9,B108,2; ICSU-4 <-> MXU-4
ZWFS:1,3,2,B77,1:1,3,11,B108,2; ICSU-4 <-> MXU-5
ZWFS:1,3,3,B76,1:1,3,9,B107,2; ICSU-5 <-> MXU-4
ZWFS:1,3,3,B77,1:1,3,11,B107,2; ICSU-5 <-> MXU-5
ZWFS:1,3,4,B76,1:1,3,9,B105,2; ICSU-6 <-> MXU-4
ZWFS:1,3,4,B77,1:1,3,11,B105,2; ICSU-6 <-> MXU-5
ZWFS:1,3,6,B76,1:1,3,9,B103,2;
ZWFS:1,3,6,B78,1:1,3,9,B117,2;
DMCU-8 <-> MXU-4
ZWFS:1,3,6,B77,1:1,3,11,B103,2;
ZWFS:1,3,6,B79,1:1,3,11,B117,2;
DMCU-8 <-> MXU-5
ZWFS:1,3,7,B76,1:1,3,9,B102,2;
ZWFS:1,3,7,B78,1:1,3,9,B118,2;
DMCU-9 <-> MXU-4
ZWFS:1,3,7,B77,1:1,3,11,B102,2;
ZWFS:1,3,7,B79,1:1,3,11,B118,2;
DMCU-9 <-> MXU-5
ZWFS:1,3,8,B76,1:1,3,9,B101,2;
ZWFS:1,3,8,B78,1:1,3,9,B116,2;
DMCU-10 <-> MXU-4
ZWFS:1,3,8,B77,1:1,3,11,B101,2;
ZWFS:1,3,8,B79,1:1,3,11,B116,2;
DMCU-10 <-> MXU-5
ZWFS:1,3,12,B76,1:1,3,9,B96,2;
ZWFS:1,3,12,B78,1:1,3,9,B115,2;
DMCU-11 <-> MXU-4
ZWFS:1,3,12,B77,1:1,3,11,B96,2;
ZWFS:1,3,12,B79,1:1,3,11,B115,2;
DMCU-11 <-> MXU-5
ZWFS:1,3,13,B76,1:1,3,9,B97,2;
ZWFS:1,3,13,B78,1:1,3,9,B114,2;
DMCU-12 <-> MXU-4
ZWFS:1,3,13,B77,1:1,3,11,B97,2;
ZWFS:1,3,13,B79,1:1,3,11,B114,2;
DMCU-12 <-> MXU-5
ZWFS:1,3,14,B76,1:1,3,9,B98,2; ICSU-7 <-> MXU-4
ZWFS:1,3,14,B77,1:1,3,11,B98,2; ICSU-7 <-> MXU-5
ZWFS:1,4,1,B76,1:1,4,9,B109,2; ICSU-8 <-> MXU-6
ZWFS:1,4,1,B77,1:1,4,11,B109,2; ICSU-8 <-> MXU-7
ZWFS:1,4,2,B76,1:1,4,9,B108,2; ICSU-9 <-> MXU-6
ZWFS:1,4,2,B77,1:1,4,11,B108,2; ICSU-9 <-> MXU-7
DN70633411 Issue 04
19 (41)
ZWFS:1,4,3,B76,1:1,4,9,B107,2; ICSU-10 <-> MXU-6
ZWFS:1,4,3,B77,1:1,4,11,B107,2; ICSU-10 <-> MXU-7
ZWFS:1,4,4,B76,1:1,4,9,B105,2; ICSU-11 <-> MXU-6
ZWFS:1,4,4,B77,1:1,4,11,B105,2; ICSU-11 <-> MXU-7
ZWFS:1,4,5,B76,1:1,4,9,B104,2; ICSU-12 <-> MXU-6
ZWFS:1,4,5,B77,1:1,4,11,B104,2; ICSU-12 <-> MXU-7
ZWFS:1,4,6,B76,1:1,4,9,B103,2;
ZWFS:1,4,6,B78,1:1,4,9,B117,2;
DMCU-13 <-> MXU-6
ZWFS:1,4,6,B77,1:1,4,11,B103,2;
ZWFS:1,4,6,B79,1:1,4,11,B117,2;
DMCU-13 <-> MXU-7
ZWFS:1,4,7,B76,1:1,4,9,B102,2;
ZWFS:1,4,7,B78,1:1,4,9,B118,2;
DMCU-14 <-> MXU-6
ZWFS:1,4,7,B77,1:1,4,11,B102,2;
ZWFS:1,4,7,B79,1:1,4,11,B118,2;
DMCU-14 <-> MXU-7
ZWFS:1,4,8,B76,1:1,4,9,B101,2;
ZWFS:1,4,8,B78,1:1,4,9,B116,2;
DMCU-15 <-> MXU-6
ZWFS:1,4,8,B77,1:1,4,11,B101,2;
ZWFS:1,4,8,B79,1:1,4,11,B116,2;
DMCU-15 <-> MXU-7
ZWFS:1,4,12,B76,1:1,4,9,B96,2;
ZWFS:1,4,12,B78,1:1,4,9,B115,2;
DMCU-16 <-> MXU-6
ZWFS:1,4,12,B77,1:1,4,11,B96,2;
ZWFS:1,4,12,B79,1:1,4,11,B115,2;
DMCU-16 <-> MXU-7
ZWFS:1,4,13,B76,1:1,4,9,B97,2;
ZWFS:1,4,13,B78,1:1,4,9,B114,2;
DMCU-17 <-> MXU-6
ZWFS:1,4,13,B77,1:1,4,11,B97,2;
ZWFS:1,4,13,B79,1:1,4,11,B114,2;
DMCU-17 <-> MXU-7
ZWFS:1,4,14,B76,1:1,4,9,B98,2; ICSU-13 <-> MXU-6
ZWFS:1,4,14,B77,1:1,4,11,B98,2; ICSU-13 <-> MXU-7
Table 10 Create connections for subrack 3 and 4 for RNAC basic cabinet
DN70633411 Issue 04
20 (41)
2.1.11 Crossover Connections for Subrack 3 and 4 for RNAC Basic Cabinet
Command Notes
ZWFS:1,1,2,B59D/B4,2:1,3,9,B57/B0,1; SFU-0 <-> MXU-4
ZWFS:1,1,2,B57D/B5,2:1,3,11,B57/B0,1; SFU-0 <-> MXU-5
ZWFS:1,2,2,B59D/B4,2:1,3,9,B67/B2,1; SFU-1 <-> MXU-4
ZWFS:1,2,2,B57D/B5,2:1,3,11,B67/B2,1; SFU-1 <-> MXU-5
ZWFS:1,1,2,B55D/B6,2:1,4,9,B57/B0,1; SFU-0 <-> MXU-6
ZWFS:1,1,2,B53D/B7,2:1,4,11,B57/B0,1; SFU-0 <-> MXU-7
ZWFS:1,2,2,B55D/B6,2:1,4,9,B67/B2,1; SFU-1 <-> MXU-6
ZWFS:1,2,2,B53D/B7,2:1,4,11,B67/B2,1; SFU-1 <-> MXU-7
Table 11 Crossover connections for subrack 3 and 4 for RNAC basic cabinet
2.1.12 Create NPS1/NPGE Connections for Subrack 3 and 4 for RNAC Basic Cabinet
Command Notes
ZWFS:1,1,2,B71/B20,2:1,3,15,B103/B0,1; SFU-0 <-> NPS1(P)-2/NPGE(P)-4
ZWFS:1,1,2,B69/B21,2:1,4,15,B103/B0,1; SFU-0 <-> NPS1(P)-3/NPGE(P)-5
ZWFS:1,2,2,B71/B20,2:1,3,15,B115/B2,1; SFU-1 <-> NPS1(P)-2/NPGE(P)-4
ZWFS:1,2,2,B69/B21,2:1,4,15,B115/B2,1; SFU-1 <-> NPS1(P)-3/NPGE(P)-5
ZWFS:1,1,2,B67/B22,2:1,3,17,B103/B0,1; SFU-0 <-> NPS1(P)-4/NPGE(P)-6
ZWFS:1,1,2,B65/B23,2:1,4,17,B103/B0,1; SFU-0 <-> NPS1(P)-5/NPGE(P)-7
ZWFS:1,2,2,B67/B22,2:1,3,17,B115/B2,1; SFU-1 <-> NPS1(P)-4/NPGE(P)-6
ZWFS:1,2,2,B65/B23,2:1,4,17,B115/B2,1; SFU-1 <-> NPS1(P)-5/NPGE(P)-7
ZWFS:1,3,15,B96D,0:1,1,19,B32/B107,0; NPS1(P)-2 <-> TBU-0
ZWFS:1,3,15,B98D,0:1,2,38,B32/B107,0; NPS1(P)-2 <-> TBU-1
ZWFS:1,4,15,B96D,0:1,1,19,B33/B108,0; NPS1(P)-3 <-> TBU-0
DN70633411 Issue 04
21 (41)
ZWFS:1,4,15,B98D,0:1,2,38,B33/B108,0; NPS1(P)-3 <-> TBU-1
ZWFS:1,3,17,B96D,0:1,1,19,B34/B109,0; NPS1(P)-4 <-> TBU-0
ZWFS:1,3,17,B98D,0:1,2,38,B34/B109,0; NPS1(P)-4 <-> TBU-1
Table 12 Create NPS1(P)/NPGE(P) connections for subrack 3 and 4 for RNAC basic cabinet
DN70633411 Issue 04
22 (41)
2.1.13 Create Functional Units to Subracks in RNAC Basic Cabinet
We recommend waiting for 2 minutes between consecutive DMCUs and/or ICSU functional unit creations (ZWFU commands). Otherwise, PROFIC supervision failure will occur and ICSU/RSMU will restart via alarm 1023.
Command Notes
ZWFU:SFU,0::1,1,2;
ZWFU:ICSU,0::1,1,3;
ZWFU:RSMU,0::1,1,4;
ZWFU:DMCU,0::1,1,7;
ZWFU:DMCU,1::1,1,8;
ZWFU:MXU,0::1,1,9;
ZWFU:MXU,1::1,1,11;
ZWFU:DMCU,2::1,1,12;
ZWFU:DMCU,3::1,1,13;
ZWFU:WDU,0:OMU:1,1,14;
ZWFU:OMU,0::1,1,16;
ZWFU:<unit type>,0::1,1,17;
or
ZWFU:<unit type>,0::1,1,17;
Unit type is NPGE or NPGEP
Unit type is NPS1 or NPS1P, an alternative to NPGE(P) unit
ZWFU:<unit type>,2::1,1,18; Unit type is NPGE or NPGEP
ZWFU:TBU,0::1,1,19;
ZWFU:TBU,1::1,1,38;
Table 13 Create functional units to subrack 1 in RNAC basic cabinet
Command Notes
ZWFU:SFU,1::1,2,2;
ZWFU:ICSU,1::1,2,3;
ZWFU:RSMU,1::1,2,4;
ZWFU:ICSU,2::1,2,6;
DN70633411 Issue 04
23 (41)
ZWFU:DMCU,4::1,2,7;
ZWFU:DMCU,5::1,2,8;
ZWFU:MXU,2::1,2,9;
ZWFU:MXU,3::1,2,11;
ZWFU:DMCU,6::1,2,12;
ZWFU:DMCU,7::1,2,13;
ZWFU:WDU,1:OMU:1,2,14;
ZWFU:OMU,1::1,2,16;
ZWFU:<unit type>,1::1,2,17;
or
ZWFU:<unit type>,1::1,2,17;
Unit type is NPGE or NPGEP
Unit type is NPS1 or NPS1P, an alternative to NPGE(P) unit
ZWFU:<unit type>,3::1,2,18; Unit type is NPGE or NPGEP
ZWFU:TBU,0::1,2,19;
ZWFU:TBU,1::1,2,38;
Table 14 Create functional units to subrack 2 in RNAC basic cabinet
Command Notes
ZWFU:ICSU,3::1,3,1;
ZWFU:ICSU,4::1,3,2;
ZWFU:ICSU,5::1,3,3;
ZWFU:ICSU,6::1,3,4;
ZWFU:EHU,0::1,3,5;
ZWFU:DMCU,8::1,3,6;
ZWFU:DMCU,9::1,3,7;
ZWFU:DMCU,10::1,3,8;
ZWFU:MXU,4::1,3,9;
ZWFU:MXU,5::1,3,11;
ZWFU:DMCU,11::1,3,12;
ZWFU:DMCU,12::1,3,13;
ZWFU:ICSU,7::1,3,14;
DN70633411 Issue 04
24 (41)
ZWFU:<unit type>,2::1,3,15;
or
ZWFU:<unit type>,4::1,3,15;
Unit type is NPS1 or NPS1P
Unit type is NPGE or NPGEP, an alternative to NPS1(P) unit
ZWFU:<unit type>,4::1,3,17;
or
ZWFU:<unit type>,6::1,3,17;
Unit type is NPS1 or NPS1P
Unit type is NPGE or NPGEP, an alternative to NPS1(P) unit
ZWFU:TBU,0::1,3,19;
ZWFU:TBU,1::1,3,38;
Table 15 Create functional units to subrack 3 in RNAC basic cabinet
Command Notes
ZWFU:ICSU,8::1,4,1;
ZWFU:ICSU,9::1,4,2;
ZWFU:ICSU,10::1,4,3;
ZWFU:ICSU,11::1,4,4;
ZWFU:ICSU,12::1,4,5;
ZWFU:DMCU,13::1,4,6;
ZWFU:DMCU,14::1,4,7;
ZWFU:DMCU,15::1,4,8;
ZWFU:MXU,6::1,4,9;
ZWFU:MXU,7::1,4,11;
ZWFU:DMCU,16::1,4,12;
ZWFU:DMCU,17::1,4,13;
ZWFU:ICSU,13::1,4,14;
ZWFU:<unit type>,3::1,4,15;
or
ZWFU:<unit type>,5::1,4,15;
Unit type is NPS1 or NPS1P
Unit type is NPGE or NPGEP, an alternative to NPS1(P) unit
ZWFU:<unit type>,5::1,4,17;
or
ZWFU:<unit type>,7::1,4,17;
Unit type is NPS1 or NPS1P
Unit type is NPGE or NPGEP, an alternative to NPS1(P) unit
ZWFU:TBU,0::1,4,19;
DN70633411 Issue 04
25 (41)
ZWFU:TBU,1::1,4,38;
Table 16 Create functional units to subrack 4 in RNAC basic cabinet
DN70633411 Issue 04
26 (41)
2.2 Equipping the RNBC Extension Cabinet for RNC2600
2.2.1 Create RNBC Extension Cabinet
Command Notes
ZWFJ:EC216,2,1B; Create a cabinet 2 (EC-216)
Table 17 Create RNBC extension cabinet
2.2.2 Create Subracks to RNBC Extension Cabinet
Command Notes
ZWFC:SRA3,2,1,1B1-0; Create a subrack 1 in cabinet 2 (SRA3)
ZWFC:SRA3,2,2,1B2-0; Create a subrack 2 in cabinet 2 (SRA3)
ZWFC:SRA3,2,3,1B3-0;
Create a subrack 3 in cabinet 2 (SRA3)
ZWFC:SRA3,2,4,1B4-0; Create a subrack 3 in cabinet 2 (SRA3)
Table 18 Create subracks to RNBC basic cabinet
DN70633411 Issue 04
27 (41)
2.2.3 Create Plug-in Units for Subrack 1 in RNBC Extension Cabinet
Command Notes
ZWFP:<piu type>,2,1,1; Create ICSU-14
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,1,2; Create ICSU-15
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,1,3; Create ICSU-16
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,1,4; Create ICSU-17
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,1,5; Create ICSU-18
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:CDSP_DH,2,1,6; Create DMCU-18
ZWFP:CDSP_DH,2,1,7; Create DMCU-19
ZWFP:CDSP_DH,2,1,8; Create DMCU-20
ZWFP:MX1G6_A,2,1,9; Create MXU-8
ZWFP:PD30,2,1,10; Create PD30
ZWFP:MX1G6_A,2,1,11; Create MXU-9
ZWFP:CDSP_DH,2,1,12; Create DMCU-21
ZWFP:CDSP_DH,2,1,13; Create DMCU-22
ZWFP:<piu type>,2,1,14; Create ICSU-19
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:NP8S1_B,2,1,15;
or
ZWFP:NP2GE_B,2,1,15;
Create NPS1(P)-6/NPGE(P)-8
ZWFP:NP8S1_B,2,1,17;
or
ZWFP:NP2GE_B,2,1,17;
Create NPS1(P)-8/NPGE(P)-10
ZWFP:TBUF,2,1,19; Create TBUF
ZWFP:TBUF,2,1,38; Create TBUF
Table 19 Create plug-in units for subrack 1 in RNBC extension cabinet
DN70633411 Issue 04
28 (41)
2.2.4 Create Plug-in Units for Subrack 2 in RNBC Extension Cabinet
Command Notes
ZWFP:<piu type>,2,2,1; Create ICSU-20
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,2,2; Create ICSU-21
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,2,3; Create ICSU-22
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,2,4; Create ICSU-23
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,2,5; Create ICSU-24
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:CDSP_DH,2,2,6; Create DMCU-23
ZWFP:CDSP_DH,2,2,7; Create DMCU-24
ZWFP:CDSP_DH,2,2,8; Create DMCU-25
ZWFP:MX1G6_A,2,2,9; Create MXU-10
ZWFP:PD30,2,2,10; Create PD30
ZWFP:MX1G6_A,2,2,11; Create MXU-11
ZWFP:CDSP_DH,2,2,12; Create DMCU-26
ZWFP:CDSP_DH,2,2,13; Create DMCU-27
ZWFP:<piu type>,2,2,14; Create ICSU-25
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:NP8S1_B,2,2,15;
or ZWFP:NP2GE_B,2,2,15;
Create NPS1(P)-7/NPGE(P)-9
ZWFP:NP8S1_B,2,2,17;
or ZWFP:NP2GE_B,2,2,17;
Create NPS1(P)-9/NPGE(P)-11
ZWFP:TBUF,2,2,19; Create TBUF
ZWFP:TBUF,2,2,38; Create TBUF
Table 20 Create plug-in units for subrack 2 in RNBC extension cabinet
DN70633411 Issue 04
29 (41)
2.2.5 Create Plug-in Units for Subrack 3 in RNBC Extension Cabinet
Command Notes
ZWFP:<piu type>,2,3,1; Create ICSU-26
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,3,2; Create ICSU-27
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,3,3; Create ICSU-28
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,3,4; Create ICSU-29
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,3,5; Create ICSU-30
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:CDSP_DH,2,3,6; Create DMCU-28
ZWFP:CDSP_DH,2,3,7; Create DMCU-29
ZWFP:CDSP_DH,2,3,8; Create DMCU-30
ZWFP:MX1G6_A,2,3,9; Create MXU-12
ZWFP:PD30,2,3,10; Create PD30
ZWFP:MX1G6_A,2,3,11; Create MXU-13
ZWFP:CDSP_DH,2,3,12; Create DMCU-31
ZWFP:CDSP_DH,2,3,13; Create DMCU-32
ZWFP:<piu type>,2,3,14; Create ICSU-31
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:NP8S1_B,2,3,15;
or
ZWFP:NP2GE_B,2,3,15;
Create NPS1(P)-10/NPGE(P)-12
ZWFP:NP8S1_B,2,3,17;
or
ZWFP:NP2GE_B,2,3,17;
Create NPS1(P)-12/NPGE(P)-14
ZWFP:TBUF,2,3,19; Create TBUF
ZWFP:TBUF,2,3,38; Create TBUF
Table 21 Create plug-in units for subrack 3 in RNBC extension cabinet
DN70633411 Issue 04
30 (41)
2.2.6 Create Plug-in Units for Subrack 4 in RNBC Extension Cabinet
Command Notes
ZWFP:<piu type>,2,4,1; Create ICSU-32
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,4,2; Create ICSU-33
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,4,3; Create ICSU-34
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,4,4; Create ICSU-35
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:<piu type>,2,4,5; Create ICSU-36
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:CDSP_DH,2,4,6; Create DMCU-33
ZWFP:CDSP_DH,2,4,7; Create DMCU-34
ZWFP:CDSP_DH,2,4,8; Create DMCU-35
ZWFP:MX1G6_A,2,4,9; Create MXU-14
ZWFP:PD30,2,4,10; Create PD30
ZWFP:MX1G6_A,2,4,11; Create MXU-15
ZWFP:CDSP_DH,2,4,12; Create DMCU-36
ZWFP:CDSP_DH,2,4,13; Create DMCU-37
ZWFP:<piu type>,2,4,14; Create ICSU-37
Plug-in unit type is CCP18_A, CCP18_C or CCP1D_A
ZWFP:NP8S1_B,2,4,15;
or
ZWFP:NP2GE_B,2,4,15;
Create NPS1(P)-11/NPGE(P)-13
ZWFP:NP8S1_B,2,4,17;
or
ZWFP:NP2GE_B,2,4,17;
Create NPS1(P)-13/NPGE(P)-15
ZWFP:TBUF,2,4,19; Create TBUF
ZWFP:TBUF,2,4,38; Create TBUF
Table 22 Create plug-in units for subrack 4 in RNBC extension cabinet
DN70633411 Issue 04
31 (41)
2.2.7 Create Connections for Subrack 1 in RNBC Extension Cabinet
Command Notes
ZWFS:2,1,1,B76,1:2,1,9,B109,2; ICSU-14 <-> MXU-8
ZWFS:2,1,1,B77,1:2,1,11,B109,2; ICSU-14 <-> MXU-9
ZWFS:2,1,2,B76,1:2,1,9,B108,2; ICSU-15 <-> MXU-8
ZWFS:2,1,2,B77,1:2,1,11,B108,2; ICSU-15 <-> MXU-9
ZWFS:2,1,3,B76,1:2,1,9,B107,2; ICSU-16 <-> MXU-8
ZWFS:2,1,3,B77,1:2,1,11,B107,2; ICSU-16 <-> MXU-9
ZWFS:2,1,4,B76,1:2,1,9,B105,2; ICSU-17 <-> MXU-8
ZWFS:2,1,4,B77,1:2,1,11,B105,2; ICSU-17 <-> MXU-9
ZWFS:2,1,5,B76,1:2,1,9,B104,2; ICSU-18 <-> MXU-8
ZWFS:2,1,5,B77,1:2,1,11,B104,2; ICSU-18 <-> MXU-9
ZWFS:2,1,6,B76,1:2,1,9,B103,2;
ZWFS:2,1,6,B78,1:2,1,9,B117,2;
DMCU-18 <-> MXU-8
ZWFS:2,1,6,B77,1:2,1,11,B103,2;
ZWFS:2,1,6,B79,1:2,1,11,B117,2;
DMCU-18 <-> MXU-9
ZWFS:2,1,7,B76,1:2,1,9,B102,2;
ZWFS:2,1,7,B78,1:2,1,9,B118,2;
DMCU-19 <-> MXU-8
ZWFS:2,1,7,B77,1:2,1,11,B102,2;
ZWFS:2,1,7,B79,1:2,1,11,B118,2;
DMCU-19 <-> MXU-9
ZWFS:2,1,8,B76,1:2,1,9,B101,2;
ZWFS:2,1,8,B78,1:2,1,9,B116,2;
DMCU-20 <-> MXU-8
ZWFS:2,1,8,B77,1:2,1,11,B101,2;
ZWFS:2,1,8,B79,1:2,1,11,B116,2;
DMCU-20 <-> MXU-9
ZWFS:2,1,12,B76,1:2,1,9,B96,2;
ZWFS:2,1,12,B78,1:2,1,9,B115,2;
DMCU-21 <-> MXU-8
ZWFS:2,1,12,B77,1:2,1,11,B96,2;
ZWFS:2,1,12,B79,1:2,1,11,B115,2;
DMCU-21 <-> MXU-9
ZWFS:2,1,13,B76,1:2,1,9,B97,2;
ZWFS:2,1,13,B78,1:2,1,9,B114,2;
DMCU-22 <-> MXU-8
ZWFS:2,1,13,B77,1:2,1,11,B97,2; DMCU-22 <-> MXU-9
DN70633411 Issue 04
32 (41)
ZWFS:2,1,13,B79,1:2,1,11,B114,2;
ZWFS:2,1,14,B76,1:2,1,9,B98,2; ICSU-19 <-> MXU-8
ZWFS:2,1,14,B77,1:2,1,11,B98,2; ICSU-19 <-> MXU-9
ZWFS:1,1,2,B121/B8,2:2,1,9,B57/B0,1; SFU-0 <-> MXU-8
ZWFS:1,2,2,B121/B8,2:2,1,9,B67/B2,1; SFU-1 <-> MXU-8
ZWFS:1,1,2,B119/B9,2:2,1,11,B57/B0,1; SFU-0 <-> MXU-9
ZWFS:1,2,2,B119/B9,2:2,1,11,B67/B2,1; SFU-1 <-> MXU-9
Table 23 Create connections for subrack 1 in RNBC extension cabinet
DN70633411 Issue 04
33 (41)
2.2.8 Create Connections for Subrack 2 in RNBC Extension Cabinet
Command Notes
ZWFS:2,2,1,B76,1:2,2,9,B109,2; ICSU-20 <-> MXU-10
ZWFS:2,2,1,B77,1:2,2,11,B109,2; ICSU-20 <-> MXU-11
ZWFS:2,2,2,B76,1:2,2,9,B108,2; ICSU-21 <-> MXU-10
ZWFS:2,2,2,B77,1:2,2,11,B108,2; ICSU-21 <-> MXU-11
ZWFS:2,2,3,B76,1:2,2,9,B107,2; ICSU-22 <-> MXU-10
ZWFS:2,2,3,B77,1:2,2,11,B107,2; ICSU-22 <-> MXU-11
ZWFS:2,2,4,B76,1:2,2,9,B105,2; ICSU-23 <-> MXU-10
ZWFS:2,2,4,B77,1:2,2,11,B105,2; ICSU-23 <-> MXU-11
ZWFS:2,2,5,B76,1:2,2,9,B104,2; ICSU-24 <-> MXU-10
ZWFS:2,2,5,B77,1:2,2,11,B104,2; ICSU-24 <-> MXU-11
ZWFS:2,2,6,B76,1:2,2,9,B103,2;
ZWFS:2,2,6,B78,1:2,2,9,B117,2;
DMCU-23 <-> MXU-10
ZWFS:2,2,6,B77,1:2,2,11,B103,2;
ZWFS:2,2,6,B79,1:2,2,11,B117,2;
DMCU-23 <-> MXU-11
ZWFS:2,2,7,B76,1:2,2,9,B102,2;
ZWFS:2,2,7,B78,1:2,2,9,B118,2;
DMCU-24 <-> MXU-10
ZWFS:2,2,7,B77,1:2,2,11,B102,2;
ZWFS:2,2,7,B79,1:2,2,11,B118,2;
DMCU-24 <-> MXU-11
ZWFS:2,2,8,B76,1:2,2,9,B101,2;
ZWFS:2,2,8,B78,1:2,2,9,B116,2;
DMCU-25 <-> MXU-10
ZWFS:2,2,8,B77,1:2,2,11,B101,2;
ZWFS:2,2,8,B79,1:2,2,11,B116,2;
DMCU-25 <-> MXU-11
ZWFS:2,2,12,B76,1:2,2,9,B96,2;
ZWFS:2,2,12,B78,1:2,2,9,B115,2;
DMCU-26 <-> MXU-10
ZWFS:2,2,12,B77,1:2,2,11,B96,2;
ZWFS:2,2,12,B79,1:2,2,11,B115,2;
DMCU-26 <-> MXU-11
ZWFS:2,2,13,B76,1:2,2,9,B97,2;
ZWFS:2,2,13,B78,1:2,2,9,B114,2;
DMCU-27 <-> MXU-10
ZWFS:2,2,13,B77,1:2,2,11,B97,2;
ZWFS:2,2,13,B79,1:2,2,11,B114,2;
DMCU-27 <-> MXU-11
DN70633411 Issue 04
34 (41)
ZWFS:2,2,14,B76,1:2,2,9,B98,2; ICSU-25 <-> MXU-10
ZWFS:2,2,14,B77,1:2,2,11,B98,2; ICSU-25 <-> MXU-11
ZWFS:1,1,2,B117/B10,2:2,2,9,B57/B0,1; SFU-0 <-> MXU-10
ZWFS:1,2,2,B117/B10,2:2,2,9,B67/B2,1; SFU-1 <-> MXU-10
ZWFS:1,1,2,B115/B11,2:2,2,11,B57/B0,1; SFU-0 <-> MXU-11
ZWFS:1,2,2,B115/B11,2:2,2,11,B67/B2,1; SFU-1 <-> MXU-11
Table 24 Create connections for subrack 2 in RNBC extension cabinet
2.2.9 Create NPS1/NPGE Connections for Subrack 1 and 2 in RNBC Extension Cabinet
Command Notes
ZWFS:1,1,2,B59/B24,2:2,1,15,B103/B0,1; SFU-0 <-> NPS1(P)-6/NPGE(P)-8
ZWFS:1,1,2,B57/B25,2:2,2,15,B103/B0,1; SFU-0 <-> NPS1(P)-7/NPGE(P)-9
ZWFS:1,2,2,B59/B24,2:2,1,15,B115/B2,1; SFU-1 <-> NPS1(P)-6/NPGE(P)-8
ZWFS:1,2,2,B57/B25,2:2,2,15,B115/B2,1; SFU-1 <-> NPS1(P)-7/NPGE(P)-9
ZWFS:1,1,2,B55/B26,2:2,1,17,B103/B0,1; SFU-0 <-> NPS1(P)-8/NPGE(P)-10
ZWFS:1,1,2,B53/B27,2:2,2,17,B103/B0,1; SFU-0 <-> NPS1(P)-9/NPGE(P)-11
ZWFS:1,2,2,B55/B26,2:2,1,17,B115/B2,1; SFU-1 <-> NPS1(P)-8/NPGE(P)-10
ZWFS:1,2,2,B53/B27,2:2,2,17,B115/B2,1; SFU-1 <-> NPS1(P)-9/NPGE(P)-11
Table 25 Create NPS1(P)/NPGE(P) connections for subrack 1 and 2 in RNBC extension cabinet
2.2.10 Create Connections for Subrack 3 in RNBC Extension Cabinet
Command Notes
ZWFS:2,3,1,B76,1:2,3,9,B109,2; ICSU-26 <-> MXU-12
DN70633411 Issue 04
35 (41)
ZWFS:2,3,1,B77,1:2,3,11,B109,2; ICSU-26 <-> MXU-13
ZWFS:2,3,2,B76,1:2,3,9,B108,2; ICSU-27 <-> MXU-12
ZWFS:2,3,2,B77,1:2,3,11,B108,2; ICSU-27 <-> MXU-13
ZWFS:2,3,3,B76,1:2,3,9,B107,2; ICSU-28 <-> MXU-12
ZWFS:2,3,3,B77,1:2,3,11,B107,2; ICSU-28 <-> MXU-13
ZWFS:2,3,4,B76,1:2,3,9,B105,2; ICSU-29 <-> MXU-12
ZWFS:2,3,4,B77,1:2,3,11,B105,2; ICSU-29 <-> MXU-13
ZWFS:2,3,5,B76,1:2,3,9,B104,2; ICSU-30 <-> MXU-12
ZWFS:2,3,5,B77,1:2,3,11,B104,2; ICSU-30 <-> MXU-13
ZWFS:2,3,6,B76,1:2,3,9,B103,2;
ZWFS:2,3,6,B78,1:2,3,9,B117,2;
DMCU-28 <-> MXU-12
ZWFS:2,3,6,B77,1:2,3,11,B103,2;
ZWFS:2,3,6,B79,1:2,3,11,B117,2;
DMCU-28 <-> MXU-13
ZWFS:2,3,7,B76,1:2,3,9,B102,2;
ZWFS:2,3,7,B78,1:2,3,9,B118,2;
DMCU-29 <-> MXU-12
ZWFS:2,3,7,B77,1:2,3,11,B102,2;
ZWFS:2,3,7,B79,1:2,3,11,B118,2;
DMCU-29 <-> MXU-13
ZWFS:2,3,8,B76,1:2,3,9,B101,2;
ZWFS:2,3,8,B78,1:2,3,9,B116,2;
DMCU-30 <-> MXU-12
ZWFS:2,3,8,B77,1:2,3,11,B101,2;
ZWFS:2,3,8,B79,1:2,3,11,B116,2;
DMCU-30 <-> MXU-13
ZWFS:2,3,12,B76,1:2,3,9,B96,2;
ZWFS:2,3,12,B78,1:2,3,9,B115,2;
DMCU-31 <-> MXU-12
ZWFS:2,3,12,B77,1:2,3,11,B96,2;
ZWFS:2,3,12,B79,1:2,3,11,B115,2;
DMCU-31 <-> MXU-13
ZWFS:2,3,13,B76,1:2,3,9,B97,2;
ZWFS:2,3,13,B78,1:2,3,9,B114,2;
DMCU-32 <-> MXU-12
ZWFS:2,3,13,B77,1:2,3,11,B97,2;
ZWFS:2,3,13,B79,1:2,3,11,B114,2;
DMCU-32 <-> MXU-13
ZWFS:2,3,14,B76,1:2,3,9,B98,2; ICSU-31 <-> MXU-12
ZWFS:2,3,14,B77,1:2,3,11,B98,2; ICSU-31 <-> MXU-13
ZWFS:1,1,2,B109/B12,2:2,3,9,B57/B0,1; SFU-0 <-> MXU-12
ZWFS:1,2,2,B109/B12,2:2,3,9,B67/B2,1; SFU-1 <-> MXU-12
ZWFS:1,1,2,B107/B13,2:2,3,11,B57/B0,1; SFU-0 <-> MXU-13
DN70633411 Issue 04
36 (41)
ZWFS:1,2,2,B107/B13,2:2,3,11,B67/B2,1; SFU-1 <-> MXU-13
Table 26 Create connections for subrack 3 in RNBC extension cabinet
2.2.11 Create Connections for Subrack 4 in RNBC Extension Cabinet
Command Notes
ZWFS:2,4,1,B76,1:2,4,9,B109,2; ICSU-32 <-> MXU-14
ZWFS:2,4,1,B77,1:2,4,11,B109,2; ICSU-32 <-> MXU-15
ZWFS:2,4,2,B76,1:2,4,9,B108,2; ICSU-33 <-> MXU-14
ZWFS:2,4,2,B77,1:2,4,11,B108,2; ICSU-33 <-> MXU-15
ZWFS:2,4,3,B76,1:2,4,9,B107,2; ICSU-34 <-> MXU-14
ZWFS:2,4,3,B77,1:2,4,11,B107,2; ICSU-34 <-> MXU-15
ZWFS:2,4,4,B76,1:2,4,9,B105,2; ICSU-35 <-> MXU-14
ZWFS:2,4,4,B77,1:2,4,11,B105,2; ICSU-35 <-> MXU-15
ZWFS:2,4,5,B76,1:2,4,9,B104,2; ICSU-36 <-> MXU-14
ZWFS:2,4,5,B77,1:2,4,11,B104,2; ICSU-36 <-> MXU-15
ZWFS:2,4,6,B76,1:2,4,9,B103,2;
ZWFS:2,4,6,B78,1:2,4,9,B117,2;
DMCU-33 <-> MXU-14
ZWFS:2,4,6,B77,1:2,4,11,B103,2;
ZWFS:2,4,6,B79,1:2,4,11,B117,2;
DMCU-33 <-> MXU-15
ZWFS:2,4,7,B76,1:2,4,9,B102,2;
ZWFS:2,4,7,B78,1:2,4,9,B118,2;
DMCU-34 <-> MXU-14
ZWFS:2,4,7,B77,1:2,4,11,B102,2;
ZWFS:2,4,7,B79,1:2,4,11,B118,2;
DMCU-34 <-> MXU-15
ZWFS:2,4,8,B76,1:2,4,9,B101,2;
ZWFS:2,4,8,B78,1:2,4,9,B116,2;
DMCU-35 <-> MXU-14
ZWFS:2,4,8,B77,1:2,4,11,B101,2;
ZWFS:2,4,8,B79,1:2,4,11,B116,2;
DMCU-35 <-> MXU-15
ZWFS:2,4,12,B76,1:2,4,9,B96,2;
ZWFS:2,4,12,B78,1:2,4,9,B115,2;
DMCU-36 <-> MXU-14
ZWFS:2,4,12,B77,1:2,4,11,B96,2;
ZWFS:2,4,12,B79,1:2,4,11,B115,2;
DMCU-36 <-> MXU-15
DN70633411 Issue 04
37 (41)
ZWFS:2,4,13,B76,1:2,4,9,B97,2;
ZWFS:2,4,13,B78,1:2,4,9,B114,2;
DMCU-37 <-> MXU-14
ZWFS:2,4,13,B77,1:2,4,11,B97,2;
ZWFS:2,4,13,B79,1:2,4,11,B114,2;
DMCU-37 <-> MXU-15
ZWFS:2,4,14,B76,1:2,4,9,B98,2; ICSU-37 <-> MXU-14
ZWFS:2,4,14,B77,1:2,4,11,B98,2; ICSU-37 <-> MXU-15
ZWFS:1,1,2,B105/B14,2:2,4,9,B57/B0,1; SFU-0 <-> MXU-14
ZWFS:1,2,2,B105/B14,2:2,4,9,B67/B2,1; SFU-1 <-> MXU-14
ZWFS:1,1,2,B103/B15,2:2,4,11,B57/B0,1; SFU-0 <-> MXU-15
ZWFS:1,2,2,B103/B15,2:2,4,11,B67/B2,1; SFU-1 <-> MXU-15
Table 27 Create connections for subrack 4 in RNBC extension cabinet
2.2.12 Create NPS1/NPGE Connections for Subrack 3 and 4 in RNBC Extension Cabinet
Command Notes
ZWFS:1,1,2,B47/B28,2:2,3,15,B103/B0,1; SFU-0 <-> NPS1(P)-10/NPGE(P)-12
ZWFS:1,1,2,B45/B29,2:2,4,15,B103/B0,1; SFU-0 <-> NPS1(P)-11/NPGE(P)-13
ZWFS:1,2,2,B47/B28,2:2,3,15,B115/B2,1; SFU-1 <-> NPS1(P)-10/NPGE(P)-12
ZWFS:1,2,2,B45/B29,2:2,4,15,B115/B2,1; SFU-1 <-> NPS1(P)-11/NPGE(P)-13
ZWFS:1,1,2,B43/B30,2:2,3,17,B103/B0,1; SFU-0 <-> NPS1(P)-12/NPGE(P)-14
ZWFS:1,1,2,B41/B31,2:2,4,17,B103/B0,1; SFU-0 <-> NPS1(P)-13/NPGE(P)-15
ZWFS:1,2,2,B43/B30,2:2,3,17,B115/B2,1; SFU-1 <-> NPS1(P)-12/NPGE(P)-14
ZWFS:1,2,2,B41/B31,2:2,4,17,B115/B2,1; SFU-1 <-> NPS1(P)-13/NPGE(P)-15
Table 28 Create NPS1(P)/NPGE(P) connections for subrack 3 and 4 in RNBC extension cabinet
DN70633411 Issue 04
38 (41)
2.2.13 Create Functional Units to Subracks in RNBC Extension Cabinet
We recommend waiting for 2 minutes between consecutive DMCUs and/or ICSU functional unit creations (ZWFU commands). Otherwise, PROFIC supervision failure will occur and ICSU/RSMU will restart via alarm 1023.
Command Notes
ZWFU:ICSU,14::2,1,1;
ZWFU:ICSU,15::2,1,2;
ZWFU:ICSU,16::2,1,3;
ZWFU:ICSU,17::2,1,4;
ZWFU:ICSU,18::2,1,5;
ZWFU:DMCU,18::2,1,6;
ZWFU:DMCU,19::2,1,7;
ZWFU:DMCU,20::2,1,8;
ZWFU:MXU,8::2,1,9;
ZWFU:MXU,9::2,1,11;
ZWFU:DMCU,21::2,1,12;
ZWFU:DMCU,22::2,1,13;
ZWFU:ICSU,19::2,1,14;
ZWFU:<unit type>,6::2,1,15;
or
ZWFU:<unit type>,8::2,1,15;
Unit type is NPS1 or NPS1P
Unit type is NPGE or NPGEP, an alternative to NPS1(P) unit
ZWFU:<unit type>,8::2,1,17;
or
ZWFU:<unit type>,10::2,1,17;
Unit type is NPS1 or NPS1P
Unit type is NPGE or NPGEP, an alternative to NPS1(P) unit
ZWFU:TBU,0::2,1,19;
ZWFU:TBU,1::2,1,38;
Table 29 Create functional units to subrack 1 in RNBC extension cabinet
DN70633411 Issue 04
39 (41)
Command Notes
ZWFU:ICSU,20::2,2,1;
ZWFU:ICSU,21::2,2,2;
ZWFU:ICSU,22::2,2,3;
ZWFU:ICSU,23::2,2,4;
ZWFU:ICSU,24::2,2,5;
ZWFU:DMCU,23::2,2,6;
ZWFU:DMCU,24::2,2,7;
ZWFU:DMCU,25::2,2,8;
ZWFU:MXU,10::2,2,9;
ZWFU:MXU,11::2,2,11;
ZWFU:DMCU,26::2,2,12;
ZWFU:DMCU,27::2,2,13;
ZWFU:ICSU,25::2,2,14;
ZWFU:<unit type>,7::2,2,15;
or
ZWFU:<unit type>,9::2,2,15;
Unit type is NPS1 or NPS1P
Unit type is NPGE or NPGEP, an alternative to NPS1(P) unit
ZWFU:<unit type>,9::2,2,17;
or
ZWFU:<unit type>,11::2,2,17;
Unit type is NPS1 or NPS1P
Unit type is NPGE or NPGEP, an alternative to NPS1(P) unit
ZWFU:TBU,0::2,2,19;
ZWFU:TBU,1::2,2,38;
Table 30 Create functional units to subrack 2 in RNBC extension cabinet
Command Notes
ZWFU:ICSU,26::2,3,1;
ZWFU:ICSU,27::2,3,2;
ZWFU:ICSU,28::2,3,3;
ZWFU:ICSU,29::2,3,4;
ZWFU:ICSU,30::2,3,5;
ZWFU:DMCU,28::2,3,6;
DN70633411 Issue 04
40 (41)
ZWFU:DMCU,29::2,3,7;
ZWFU:DMCU,30::2,3,8;
ZWFU:MXU,12::2,3,9;
ZWFU:MXU,13::2,3,11;
ZWFU:DMCU,31::2,3,12;
ZWFU:DMCU,32::2,3,13;
ZWFU:ICSU,31::2,3,14;
ZWFU:<unit type>,10::2,3,15;
or
ZWFU:<unit type>,12::2,3,15;
Unit type is NPS1 or NPS1P
Unit type is NPGE or NPGEP, an alternative to NPS1(P) unit
ZWFU:<unit type>,12::2,3,17;
or
ZWFU:<unit type>,14:2,3,17;
Unit type is NPS1 or NPS1P
Unit type is NPGE or NPGEP, an alternative to NPS1(P) unit
ZWFU:TBU,0::2,3,19;
ZWFU:TBU,1::2,3,38;
Table 31 Create functional units to Subrack 3 in RNBC extension cabinet
Command Notes
ZWFU:ICSU,32::2,4,1;
ZWFU:ICSU,33::2,4,2;
ZWFU:ICSU,34::2,4,3;
ZWFU:ICSU,35::2,4,4;
ZWFU:ICSU,36::2,4,5;
ZWFU:DMCU,33::2,4,6;
ZWFU:DMCU,34::2,4,7;
ZWFU:DMCU,35::2,4,8;
ZWFU:MXU,14::2,4,9;
ZWFU:MXU,15::2,4,11;
ZWFU:DMCU,36::2,4,12;
ZWFU:DMCU,37::2,4,13;
ZWFU:ICSU,37::2,4,14;
DN70633411 Issue 04
41 (41)
ZWFU:<unit type>,11::2,4,15;
or
ZWFU:<unit type>,13::2,4,15;
Unit type is NPS1 or NPS1P
Unit type is NPGE or NPGEP, an alternative to NPS1(P) unit
ZWFU:<unit type>,13::2,4,17;
or
ZWFU:<unit type>,15::2,4,17;
Unit type is NPS1 or NPS1P
Unit type is NPGE or NPGEP, an alternative to NPS1(P) unit
ZWFU:TBU,0::2,4,19;
ZWFU:TBU,1::2,4,38;
Table 32 Create functional units to Subrack 4 in RNBC extension cabinet