3 : Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts ChapterContents Thermal Management Air-to-Water Heat Exchanger POWERLEAN™In-rowCoolingUnits ................................ 4 Data Center Floor Brush Kits DataCenterFloorBrushKits ....................................... 8 2-PieceFlush-MountFloorBrushKitwithCover.................... 9 1-PieceFlush-MountFloorBrushKitwithCoverandTwo-Stage Sealing............................................................ 9 2-PieceSurface-MountRetrofitFloorBrushKits ................... 10 AdjustableFloorBrushKits ....................................... 10 Fan Tray 19-in.Rack-MountFanTray ....................................... 11 FanSpeedControls............................................... 12 Compact Cooling Fans and Accessories CompactCoolingFans ............................................ 13 FanFilterandFingerGuardKit.................................... 15 FanCords ......................................................... 15 FingerGuards .................................................... 15 TemperatureControlSwitches.................................... 16 Tool-less(Snap-in)BlankingPanelsfor19-in.Racks................ 17 Cooling Fan and Exhaust Packages with Accessories CoolingFanandExhaustPackages ................................ 18 OptionalGrillesandReplacementFilters.......................... 20 EMCFan/GrilleUpgradeKit....................................... 21 Fan Shroud Kit FanShroudKit,Type3R .......................................... 22 CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

3

:

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

ChapterContentsThermal Management

Air-to-Water Heat ExchangerPOWERLEAN™In-rowCoolingUnits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Data Center Floor Brush KitsDataCenterFloorBrushKits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82-PieceFlush-MountFloorBrushKitwithCover . . . . . . . . . . . . . . . . . . . . 91-PieceFlush-MountFloorBrushKitwithCoverandTwo-StageSealing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92-PieceSurface-MountRetrofitFloorBrushKits . . . . . . . . . . . . . . . . . . .10AdjustableFloorBrushKits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Fan Tray19-in.Rack-MountFanTray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11FanSpeedControls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Compact Cooling Fans and AccessoriesCompactCoolingFans. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13FanFilterandFingerGuardKit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15FanCords. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15FingerGuards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15TemperatureControlSwitches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16Tool-less(Snap-in)BlankingPanelsfor19-in.Racks. . . . . . . . . . . . . . . . 17

Cooling Fan and Exhaust Packages with AccessoriesCoolingFanandExhaustPackages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18OptionalGrillesandReplacementFilters. . . . . . . . . . . . . . . . . . . . . . . . . .20EMCFan/GrilleUpgradeKit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

Fan Shroud KitFanShroudKit,Type3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 2: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

4

Networking:ThermalManagement

Air-to-WaterHeatExchanger

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

NetworkingThermal ManagementAir-to-Water Heat Exchanger

POWERLEAN™In-rowCoolingUnits

IndustryStandardsETLListed

Application• Smalltolargedatacenters• Wiringclosets• Serverrooms

Features• Close-coupledsolutionutilizeschilledwatertoremoveITheatload• Top-feedwaterlinesforconcretefloors.Alsoavailableinbottom-

feedmodels(non-standardconfiguration).• Innovativedirect-driveECmotorandairfoilfandesigneasily

overcomesstaticpressure• Highefficiencydesignprovides82%energysavingsversus

competitiveofferings• Superioracousticperformanceforquietoperation• 460V3-phasepowerinput• Replaceablefiltersareeasilyaccessible• Disconnectswitchinfrontofpanel• OptionalCommunicationProtocolavailable(SNMP,MODBUS,

BACnet)• OptionalControlleravailable• Optional90-in.-tallunitavailableforcoolingcapacityupto74kW

Specifications• VariableSpeed• FilterSize:4in.(102mm)• Color:Black• FanArrangement:2• TypeofFan:Plenum• ControlPanel:PLC• InputConnections:HardWire• InputFrequency:60Hz• kWinputto1kWcooledat85Fairtemp:.013kW• kWinputto1kWcooledat100Fairtemp:.009kW• EnteringCoolant:44F(6.7C)• RelativeHumidity:45%• InputVoltage:460V3-Phase• Nominalcoolingcapacity31and52kWat85Fairtemperature• Close-coupledchilledwatercooling• PL782442IR3utilizesthree20x24x4MERV10filters• PL783642IR5utilizesthree20x24x4MERV10filtersandthree

12x24x4MERV10filters• 3-WayValve(Optional)• DualFloatPump(Optional)• BMSCompatibleController(Optional)• CommunicationProtocolsSNMP,BACnet,Modbus(Optional)

Finish• RAL9005black,semi-textured,powder-coatpaint• Othercolorsandtexturesavailable

Bulletin:DPLN,DTHRM

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 3: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

5

Networking:ThermalManagement

Air-to-WaterHeatExchanger

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

StandardProduct 

CatalogNumber AxBxCin./mm

CoolingCapacityat85F(kW)

CoolingCapacityat100F(kW) CFM

PressureDrop(ft./H2O

FluidFlow(GPM)

FluidFlow(LPM) Power(kW) NoisedB(A)

ShippingWeight(lb.)

ShippingWeight(kg)

PL782442IR3 78.00 x 24.00 x 42.00 1981 x 610 x 1067

31 43 4600 14.3 13.9 52.6 .40 60 550 249

PL783642IR5 78.00 x 36.00 x 42.00 1981 x 914 x 1067

52 71 7600 15.3 23.1 87.4 .67 63 825 374

CoolingCapacity (PL782442IR3)EnterDryBulb(°F/°C)

LeaveDryBulb(°F/°C)

LeaveWetBulb(°F/°C)

AirVolume(CFM)

FaceVelocity

EnteringWaterTemp(°F/°C)

FluidRise(°F/°C)

FluidFlow(GPM)

TotalCoolingCapacity(MBH)

TotalCoolingCapacity(kW)

TotalUnitPDft.(H2O)

TotalMotor(kW)

TotalMotor(BHP)

TotalMotor(HP)

75 / 24 59 / 15 54 / 12 4600 569 44 / 7 11.4 / -11 13.9 79.7 23.3 14.5 0.4 0.54 180 / 27 61 / 16 53 / 12 4600 569 44 / 7 13.5 / -10 13.9 94.2 27.6 14.5 0.4 0.54 185 / 29 64 / 18 52 / 11 4600 569 44 / 7 15.2 / -9 13.9 105.9 31.0 14.4 0.4 0.54 190 / 32 66 / 19 50 / 10 4600 569 44 / 7 17.1 / -8 13.9 119.0 34.9 14.3 0.4 0.54 195 / 35 69 / 21 49 / 9 4600 569 44 / 7 19.0 / -7 13.9 132.0 38.7 14.3 0.4 0.54 1100 / 38 71 / 22 48 / 9 4600 569 44 / 7 20.9 / -6 13.9 145.1 42.5 14.2 0.4 0.54 1

CoolingCapacity (PL783642IR5)EnterDryBulb(°F/°C)

LeaveDryBulb(°F/°C)

LeaveWetBulb(°F/°C)

AirVolume(CFM)

FaceVelocity

EnteringWaterTemp(°F/°C)

FluidRise(°F/°C)

FluidFlow(GPM)

TotalCoolingCapacity(MBH)

TotalCoolingCapacity(kW)

TotalUnitPDft.(H2O)

TotalMotor(kW)

TotalMotor(BHP)

TotalMotor(HP)

75 / 24 59 / 15 54 / 12 7600 572 44 / 7 11.4 / -11 23.1 132.9 38.9 15.5 1.0 0.90 1.580 / 27 61 / 16 53 / 12 7600 572 44 / 7 13.5 / -10 23.1 156.6 45.9 15.4 1.0 0.90 1.585 / 29 64 / 18 52 / 11 7600 572 44 / 7 15.2 / -9 23.1 176.4 51.7 15.4 1.0 0.90 1.590 / 32 66 / 19 50 / 10 7600 572 44 / 7 17.1 / -8 23.1 198.1 58.0 15.3 1.0 0.90 1.595 / 35 69 / 21 49 / 9 7600 572 44 / 7 19.0 / -7 23.1 219.8 64.4 15.2 1.0 0.90 1.5100 / 38 71 / 22 48 / 9 7600 572 44 / 7 20.9 / -6 23.1 241.6 70.8 15.2 1.0 0.90 1.5

ServiceParts CatalogNumber in./mm DescriptionPL05HPECMTRSP 12.00 x 12.00 x 12.00

305 x 305 x 3051/2 hp EC motor

PL003HPPMPSP 6.00 x 6.00 x 14.00 152 x 152 x 356

1/30 hp dual float condensate pump

PL24VMCCSP 0.10 x 4.00 x 8.00 3 x 102 x 203

24v ECM speed control card

PL24VCTFMSP 6.00 x 8.00 x 6.00 152 x 203 x 152

24V control transformer

PL7AMPFSSP 0.10 x 4.00 x 4.00 3 x 102 x 102

7 amp fuse

PL2AMPFSSP 0.10 x 4.00 x 4.00 3 x 102 x 102

2 amp fuse

Cabinet Door and

Frame

Coil

Fan

Air Filters

Electrical Panel

Direct Drive

Motors

Leveling Legs

Casters

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 4: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

6

Networking:ThermalManagement

Air-to-WaterHeatExchanger

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 5: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

7

Networking:ThermalManagement

Air-to-WaterHeatExchanger

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 6: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

8

Networking:ThermalManagement

DataCenterFloorBrushKits

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

Data Center Floor Brush Kits

DataCenterFloorBrushKits

IndustryStandardsDesignedtomeetthefollowingstandards:• FlameresistantVOratingperANSI/UL94(“TestsforFlammabilityof

PlasticMaterialforPartsinDevicesandAppliances”)• RoHScompliant• 2008NECcodecompliantwithrequirementsofArticle645.5(D)(5)• NFPA75Section5-4.4• HoffmanisanISO9001company

ApplicationTheseFloorBrushKitsprovideconvenient,safepassageofcablesfromunderadatacenterraisedfloorintoacabinetorrack.Theoverlappingbrushesconformaroundthecablesandblocktheflowofcoldair.Thisimprovesdatacenterefficiencyandreducesoperatingcostsbyminimizingoreliminatingupto90percentofcoldairleakagethroughtheraisedfloorcutout.

Features• Blocksupto90percentofcoldairleakagearoundpoweranddata

cables• Flushmountsprovidealowprofileandgrommettoraised-floor

panelcutouts(requiredbyNECandNFPA)• Surfacemountprovidesaneasy-to-useretrofittoexistingraised-

floorcutouts

• Adjustableflushmountprovidesanextra-largecablecapacityandcanbecuttosizetofittheapplication

• Overlappingbristlesconformarounddataandpowercablestominimizeairleakagethroughraisedfloorandimproveoveralldatacentercoolingefficiency

• Reductionofcoldairlossthroughraised-floorplenumshelpstoincreaseunderfloorstaticpressure

• Coverprovidesprotectionduringbuildout• Smooth,roundedlow-profileflushmountedgesprotectcables

fromsharpraised-flooredges• Two-piecesurfacemountandadjustablefloorbrushkitshaveself-

stickingadhesivetoexpediteinstallation• Raised-floortilesneednotberemovedforinstallation• Brushkitscanalsobeusedoncabinetsorotherlocations

thatneedtoprovidecableegressandpreventairleakageorcontaminantsfromentering

• Self-tappingscrewsincluded

Specifications• ABSpolycarbonatehousing• Nylonpolymerbristles• EPDMgasket

FinishBlackfinishinsideandout

CableFillforDataCenterFloorBrushKits CableCategory 5e 6 6ADiameter (in.) .22 .25 .30Area (in.2) .0380 .0491 .0707

CableAreaandFill 

CatalogNumberUsableCableAreaDxE(in.) Area(in.2)

No.Cablesat60%Fill5e

No.Cablesat60%Fill6

No.Cablesat60%Fill6A

DFB410F 9.25 x 3.00 27.75 438 339 235DFB57F 7.49 x 4.86 36.40 575 445 309DFB66S 7.00 x 6.25 43.75 691 535 371DFBA1024F 23.50 x 9.19 215.97 3409 2639 1833

DFBA1024F - at maximum size.

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 7: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

9

Networking:ThermalManagement

DataCenterFloorBrushKits

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

2-PieceFlush-MountFloorBrushKitwithCover

UseFlush-MountFloorBrushKitwithremovablebrushandsolidcoverfornewinstallations.Installtwokitswhenlargebundlesofcablesareneeded.Removablebackbrushallowsfloortileremovalwithoutdisconnectingcables.There’snoneedforanoversizedcutoutbecausetheremovablebackbrushallowslargeconnectorstopassthroughthegrommet.Removablesolidsafetycoverallowsinstallationofthegrommetduringtheconstructionphaseandeliminatestheriskofinjurybysteppingthroughthegrommetopening.OSHAjobsitestandardsrequireopenholesinfloorpanelstobecovered.NEC,ULandNEMArequiresafetycoversandcableprotectionagainstsharpedges.Bulletin:DACCY

CatalogNumber DescriptionMax.HxWxDin./mm

Max.DxEin./mm

DFB410F Flush-Mount Floor Brush withcover and removable brush

6.31 x 12.81 x 1.62160 x 325 x 41

3.50 x 9.5089 x 241

1-PieceFlush-MountFloorBrushKitwithCoverandTwo-StageSealing

Flush-MountFloorBrushKitwithCoverisaheavy-dutytwo-stagesealingsystem.BrushandEPDMgasketprovidethemosteffectiveairseal.Heavy-duty,integratedsafetycoverallowsinstallationofthegrommetduringtheconstructionphaseandeliminatestheriskofinjurybysteppingthroughthegrommetopening.OSHAjobsitestandardsrequireopenholesinfloorpanelstobecovered.Easy-to-installsystemintegrateswiththeaccessfloorstaticdissipativesystem.NEC,ULandNEMArequiresafetycoversandcableprotectionagainstsharpedges.Bulletin:DACCY

CatalogNumber AxBxCin./mm DescriptionDxEin./mm

DFB57F 8.31 x 10.81 x 1.62 211 x 275 x 41

Flush-Mount Floor BrushKit with Cover

7.49 x 4.86190 x 123

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 8: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

10

Networking:ThermalManagement

DataCenterFloorBrushKits

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

2-PieceSurface-MountRetrofitFloorBrushKits

UseSurface-MountFloorBrushKitstocoverexistingfloorcutouts.Two-pieceassemblyretrofitsaroundexistingcableswithoutdisconnectingthecables.Mountinghardwareandadhesiveincluded.NEC,ULandNEMArequiresafetycoversandcableprotectionagainstsharpedges.Bulletin:DACCY

CatalogNumber AxBxCin./mm DescriptionDxEin./mm

DFB66S 10.00 x 10.00 x 0.85 254 x 254 x 22

Surface-Mount Floor Brush Kit 6.50 x 6.50165 x 165

AdjustableFloorBrushKits

UseFloorBrushKitstosealodd-sizedcutouts.Cut-to-fitdesigniseasytoinstallwithfactory-appliedadhesivestrips.EngineeredsiderailclipsprovidecableprotectionperNFPA75,SectionS-4.4.NEC,ULandNEMArequiresafetycoversandcableprotectionagainstsharpedges.Bulletin:DACCY

CatalogNumber DescriptionMax.HxWxDin./mm

Max.DxEin./mm

DFBA1024F Adjustable Floor Brush Kit 11.88 x 26.25 x 1.83302 x 667 x 46

9.75 x 24.00248 x 610

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 9: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

11

Networking:ThermalManagement

FanTray

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

Fan Tray

19-in.Rack-MountFanTrayApplicationFantraysenhancethenaturalconvectionairflowwithinacabinetwheninstalledwithother19-in.rack-mountequipment.

Features• Fantraysavailablewitheitherthreeorsix4-in.fans• Includes72-in.(1829-mm)powercordwithIEC320standardpower

socket• Powercordplugsintostandard115VACoutlet• Lightedrockerswitchprovideson-offcontrolandindicateswhen

fansareon

FinishRAL9005black,lightlytexturedpolyesterpowderpaintBulletin:DTHRM

StandardProducts 

CatalogNumberNumberofFans

Power(W)

MaxAirflow(CFM) C(in.) C(mm)

A19FT3B 3 45 253 8.10 206A19FT6B 6 90 506 12.96 329

 TechnicalPerformanceper4-InchFan

OperatingVoltage(VAC)

OperatingFrequency(Hz)

NominalAirflowCapacity(CFM)

NoiseLevel(dB)

Max.StaticPressure(in.WC)

Max.OperatingTemperature(°F)

Max.OperatingTemperature(°C)

PowerConsumption(W)

115 60 102 41 0.27 158 70 15

Nominal Airflow capacity rating applies to fans before installation in fan tray.

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 10: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

12

Networking:ThermalManagement

FanTray

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

FanSpeedControls

IndustryStandards(bothcontrols)UL508Listed;FileNo.E249700cULListedperCSAC22.2No.14;FileNo.E249700

ApplicationPerfectforoffices,classroomsandothernoise-sensitiveareas,FanSpeedControlsoptimizeairflowinacabinetorrack,balancingairvolumerequirementswithnoiselevelandpoweruse.

FeaturesAFANTSCPanel-MountFanSpeedControl• Automaticallyadjustsfanspeeddependingonremote

temperaturesensorinput• Temperaturesetpointisfieldadjustable;presetat35C(95F)• Idlespeedandtemperatureslopearefield-adjustable• Push-to-resetthermalcircuitbreakerinsidecontrolhousing• Compactpolycarbonatecontrolhousingcanbemountedinany

position• NEMA5-15Routletprovidespowertofan• Six-foot(1.83-m)powercordplugsintostandard120V,50or60Hz

outlet• Remotetemperaturesensorwith10-ft.(3.05-m)leadmountsin

airflow• Mountingbracketsincluded

A19FANSC19-in.Rack-MountFanSpeedControl• Continuouslyvariablefanspeedcontrolknobwithminimum

speedadjustment• Uses1RUrackspace• Steelconstruction• TwoNEMA5-15Routletsprovidepowertofan• Six-foot(1.83-m)powercordplugsintostandard120V60Hzoutlet

Finish• AFANTSC:Light-graypolycarbonatecontrolhousing• A19FANSC:RAL9005blackpolyesterpowderpaint

Bulletin:DTHRM

StandardProducts 

CatalogNumber Description ApplicationVoltageandFrequency

CurrentDraw

TemperatureSettings(ºC)

TemperatureSettings(ºF)

AFANTSC Panel-MountFan Speed Control

Fan speed controlledautomatically with remotetemperature sensor

120 VAC50/60 Hz

2 A max. 30, 35, 40, 45 86, 95, 104, 113

A19FANSC 19-in. Rack-MountFan Speed Control

Fan speedadjusted manually

120 VAC60 Hz

4 A max. Continuouslyvariable

Continuouslyvariable

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 11: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

13

Networking:ThermalManagement

CompactCoolingFansandAccessories

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

Compact Cooling Fans and Accessories

CompactCoolingFans

IndustryStandards

ULComponentRecognized

CSAcertified

ApplicationCompactCoolingFansareidealforapplicationswhereenclosurespaceislimitedandquiet,reliablecoolingisrequired.Engineeredfor50,000hoursofcontinuousoperationwithoutlubricationorservice.

InstallationCanbeinstalledonanysurfaceofanenclosure.Withtheadditionofaccessoryfanbrackets,CompactCoolingFanscanalsobeinstalledinanypositioninsidetheenclosureforspotcoolingoraircirculation.

Features• Maximumoperatingtemperatureis158F(70C)• 4-in.fanisthermallyprotectedandusespermanentlylubricated

ballbearings• 6-and10-in.fanshaveball-bearingconstructionandsplit-

capacitormotors• Split-capacitormotorsarethermallyprotectedtoavoidpremature

failure• Dynamicallybalancedimpellersmoldedfrompolycarbonate

material• Onefingerguardisfurnished(additionalfingerguardsare

available)• Allmountinghardwareisprovided

Fan bracket and additional finger guards must be purchased separately

• 240and560CFMfanshaveballbearingconstructionandsplitcapacitormotors

• Fanshaveleadwireswithendsstripped1/2-in.(12-mm)or6-ft.(1.8-m)cordwithpolarizedplugforpowerconnections

Consult your local Hoffman sales office for information on modifications to this product

FinishFanhousingisblack.Bulletin:D85

StandardProductandCutoutDimensions 

CatalogNumberNominalSize

PowerConnection Voltage

Ain./mm

Din./mm

Ein./mm

Jin./mm

Kin./mm

Lin./mm

Min./mm

A2AXFN24 2 Lead wires 24 VDC ——

1.9750

.9825

1.9750

.9825

——

——

A3AXFN 3 Lead wires 115 VAC ——

2.8171

1.4036

2.8171

1.4036

——

——

A3AXFN24 3 Lead wires 24 VDC ——

2.8171

1.4036

2.8171

1.4036

——

——

A4AXFNGQ 4 Power cord/Quiet 115 VAC 4.62117

4.12105

2.0652

4.12105

2.0652

——

——

A4AXFNPG 4 Power cord 115 VAC 4.62117

4.12105

2.0652

4.12105

2.0652

——

——

A4AXFN 4 Lead wires 115 VAC 4.62117

4.12105

2.0652

4.12105

2.0652

——

——

A4AXFN2 4 Lead wires 230 VAC 4.62117

4.12105

2.0652

4.12105

2.0652

——

——

A4AXFN24 4 Lead wires 24 VDC 4.62117

4.12105

2.0652

4.12105

2.0652

——

——

A6AXFNGQ 6 Power cord/Quiet 115 VAC 5.88149

——

——

——

——

3.1981

6.38162

A6AXFNPG 6 Power cord 115 VAC 5.88149

——

——

——

——

3.1981

6.38162

A6AXFN 6 Lead wires 115 VAC 5.88149

——

——

——

——

3.1981

6.38162

A6AXFN2 6 Lead wires 230 VAC 5.88149

——

——

——

——

3.1981

6.38162

A6AXFN24 6 Lead wires 24 VDC 5.88149

——

——

——

——

3.1981

6.38162

A10AXFNPG 10 Power cord 115 VAC 9.00229

6.88175

3.4487

6.88175

3.487

——

——

A10AXFN 10 Lead wires 115 VAC 9.00229

6.88175

3.4487

6.88175

3.4487

——

——

A10AXFN2 10 Lead wires 230 VAC 9.00229

6.88175

3.4487

6.88175

3.4487

——

——

CFM without exhaust grille

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 12: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

14

Networking:ThermalManagement

CompactCoolingFansandAccessories

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

 Technical/PerformanceDataforCompactCoolingFans

CatalogNumberNominalSize

PowerConnection Voltage

A@50/60Hz

W@50/60Hz

CFM@50/60Hz

FanSize(in.²) FanDepth

Max.MotorOperatingRPM@50/60Hz NoiseSIL(dB)

A2AXFN24 2 Lead wires 24 VDC .09 2.16 21.5 2.36 .98 in. 4550 65A3AXFN 3 Lead wires 115 VAC .09 7 27 3.15 1.50 in. 2700 40A3AXFN24 3 Lead wires 24 VDC .14 3.36 40 3.15 .98 in. 3400 35A4AXFNGQ 4 (Quiet Fan) Power cord 115 VAC .09/.08 6/5 46/49 4.69 1.52 in. 1350/1450 27/28A4AXFNPG 4 Power cord 115 VAC .26/.21 17/15 85/100 4.69 1.52 in. 2415/2900 37/41A4AXFN 4 Lead wires 115 VAC .26/.21 17/15 85/100 4.69 1.52 in. 2415/2900 37/41A4AXFN2 4 Lead wires 230 VAC .14/.11 16/14 85/100 4.69 1.52 in. 2415/2900 37/41A4AXFN24 4 Lead wires 24 VDC .35 8.4 118 4.69 1.52 in. 3200 46.5A6AXFNGQ 6 (Quiet Fan) Power cord 115 VAC .16/.19 16/18 85/102 6.77 1.50 in. 1400/1650 35/38A6AXFNPG 6 Power cord 115 VAC .45/36 36/32 200/240 6.77 1.50 in. 2670/3200 50/56A6AXFN 6 Lead wires 115 VAC .45/36 36/32 200/240 6.77 1.50 in. 2670/3200 50/56A6AXFN2 6 Lead wires 230 VAC .23/.18 39/35 200/240 6.77 1.50 in. 2670/3200 50/56A6AXFN24 6 Lead wires 24 VDC .88 21.1 280 6.77 2.00 in. 3750 62.5A10AXFNPG 10 Power cord 115 VAC 1.0/.88 36/36 480/560 10.00 3.50 in. 1350/1650 45.8/49A10AXFN 10 Lead wires 115 VAC 1.0/.88 36/36 480/560 10.00 3.50 in. 1350/1650 45.8/49A10AXFN2 10 Lead wires 230 VAC .47/.43 36/36 480/560 10.00 3.50 in. 1350/1650 45.8/49

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 13: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

15

Networking:ThermalManagement

CompactCoolingFansandAccessories

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

FanCords UsedtopowerCompactCoolingFanswhenpositivegroundofthecabinetcaseisrequired.Availablewithconnectorsforoneortwofans.Five-foot(1.52-meter)cordwithgroundedthree-prongplug.FitsA4AXFNPG,A6AXFNPG,A10AXFNPG,A4AXFNGQandA10AXFNGQ.Bulletin:DTHRM

CatalogNumber DescriptionACORD1 One connectorACORD2 Two connectors

FanFilterandFingerGuardKitLow-densityfilterkitfor4-in.(102-mm)and6-in.(152-mm)fans.Canalsobeusedasvent.Filterisremovableandcanbecleanedandreused.Mountinghardwareincluded.Bulletin:DTHRM,DWS1

CatalogNumber Description FitsAFLTR4LD Fan Filter and Finger Guard Kit 4-in. fansAFLTR6LD Fan Filter and Finger Guard Kit 6-in. fans

FingerGuards OnefingerguardisincludedwitheachCompactCoolingFanandCoolingFanPackage.AdditionalFingerGuardscanbemountedoneithersideofthefanformaximumsafety.Allguardsarechrome-platedandmeetUL507.25-in.pluggaugetest.Bulletin:D85

CatalogNumber UseonCompactCoolingFanCatalogNumbersAGARD2 A2AXFN24AGARD3 A3AXFN, A3AXFN24AGARD4 A4AXFNPG, A4XFNGQ, A4AXFN, A4AXFN2AGARD6 A6AXFNPG, A6AXFNGQ, A6AXFN, A6AXFN2AGARD10 A10AXFNPG, A10AXFNQR , A10AXFN, A10AXFN2

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 14: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

16

Networking:ThermalManagement

CompactCoolingFansandAccessories

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

FanBracketsisanexcludedproduct.(s-224374)TemperatureControlSwitches

IndustryStandards

cURus;FileNo.E164102UL94-VO

ProtectionratingIECIP30CSACertified,FileNumber215952CE

ApplicationTheseeasy-to-installthermostatsregulateandmonitorairtemperatureinenclosuresthatcontainheat-emittingequipment.Thermostatsprolongheaterandfanlifeexpectancybycontrollingoperationtimeandincreaseelectricalcomponentworkingefficiencybyexposingthemtofewerenvironmentalcontaminants.

Features• AdditionallabelforconversiontoCelsiusscaleandblanklabelto

coversetpointrangelabelwhenadjustmentafterinitialsettingisnotdesiredareincluded

• Bimetaltemperaturesensor• Plastichousing• ConnectionsconsistoftubularscrewterminalsforAWG14

(.04sq.in.)• ProvisionforbothpanelmountingandDINrailmounting

FinishMoldedplastichousingisblackBulletin:D85

StandardProduct CatalogNumber ContactType ControlApplicationATEMNC NC (normally closed), quick acting HeaterATEMNO NO (normally open), quick acting Fan

SwitchingCapacity Load AmpsMaximum load 15 A resistive / 2 A inductive @ 120 VAC

10 A resistive / 2 A inductive @ 250 VACDC 30 W

Minimum load 20 mA (all voltages)

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 15: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

17

Networking:ThermalManagement

CompactCoolingFansandAccessories

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

Tool-less(Snap-in)BlankingPanelsfor19-in.RacksTheseTool-less19-in.BlankingPanelsprovideeasytool-lessinstallationandensureproperairflowtoequipment.MadeofblackcompositematerialandcanbeusedwithtappedorsquareEIAuniversalspacedrackmountingangles.Bulletin:DACCY

CatalogNumber DescriptionRackUnits Fits

Pkg.Qty.

D19BPT1RU Blanking Panel, 19 in. 1 19 in., universal rack spacing,tapped or square holes

10

D19BPT2RU Blanking Panel, 19 in. 2 19 in., universal rack spacing,tapped or square holes

10

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 16: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

18

Networking:ThermalManagement

CoolingFanandExhaustPackageswithAccessories

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

Cooling Fan and Exhaust Packages with Accessories

CoolingFanandExhaustPackages

IndustryStandards

UL508AComponentRecognized,FileNumberE61997TFP#Models:Type1TFP#UL12Models:Type12

CSAcertified(fanonly)CE

ApplicationCoolingFanandExhaustPackagesaredesignedforlimited-spaceenclosuresthatrequireareliableandfilteredairflow.Wherepositiveairflowisnotrequired,ExhaustPackagescanbeusedonboththeinletandoutlet.Engineeredfor50,000hoursofcontinuousoperationwithoutlubricationorservice.ForbothType1andType12systemsamonthlymaintenancescheduleisrecommendedtoensureoptimalcoolingperformance.

Features• CoolingFanPackageincludesfan,airfilter,compositeairplenum,

fingerguardandgrille• ExhaustPackageincludesairfilter,filterretainerwithintegral

fingerguardandgrille• EMCUpgradeKitincludesagrillestandoffcollarandaspecialEMC

shieldinggrille• Washablefoam(Type1)ordisposable(Type12)filterinfan.

OptionalwashablealuminumairfilterisavailableforType1applications.

• Dynamically-balancedfanimpellersmoldedfrompolycarbonatematerial

• 4-in.fanisthermallyprotectedandusespermanently-lubricatedballbearings

• 6-and10-in.fanshaveballbearingconstructionandsplit-capacitormotorsthatarethermallyprotectedtoavoidprematurefailure

• Fanshaveleadwiresforpowerconnectionwithendsstripped1/2in.(12mm)

• AllmountinghardwareandinstallationinstructionsarefurnishedFiltersStandardType1airfiltersarewashablefoam.Type 12 air filters are not washable.InstallationFanandexhaustpackagescanbeinstalledonanysurfaceofanenclosure.Theyaremosteffectivewhenthefanassemblyislocatedonalowerpaneloftheenclosureandtheexhaustgrilleispositionednearthetopoftheoppositeside.Thisinstallationassistsheattransferbycausingslightlymoreturbulenceandalsoprolongstheworkinglifeofthefansinceitislocatedinthepathofthecoolerairenteringtheenclosure.Theheightandwidthofthecoolingfansandexhaustgrillescanberotated90degreesformountingonnarrowenclosures.Allowadequateclearanceforservicingthefanwhenequipmentisinstalledinsidetheenclosureandforreplacingfiltersonboththefanandtheexhaust.Cutoutdimensionsforboththefanandtheexhaustareshownintheordertable.Orderthefanandexhaustpackagesseparately.

FinishStainlesssteelgrilleshavebrushedfinish.ABScompositegrilleisblack.Bulletin:D85

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 17: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

19

Networking:ThermalManagement

CoolingFanandExhaustPackageswithAccessories

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

StandardProductandCutoutDimensions CoolingFanandExhaustPackages

CatalogNumber AxBxCin./mm MaterialandTypeUsewithExhaustGrille

NominalFanSize

Din./mm

Fin./mm

Hin./mm

Tin./mm

Win./mm

TFP424 6.29 x 7.37 x 2.35 160 x 187 x 67

Composite Grille UL 508 Type 1 TEP4 4 0.4511

5.66144

0.7720

4.12105

6.39162

TFP41 6.29 x 7.37 x 2.65 160 x 187 x 67

Composite Grille UL 508 Type 1 TEP4 4 0.4511

5.66144

0.7720

4.12105

6.39162

TFP41SS 6.29 x 7.37 x 2.65 160 x 187 x 67

Stainless Steel Grille UL 508 Type 1 TEP4SS 4 0.4511

5.66144

0.7720

4.12105

6.39162

TFP41UL12 6.29 x 7.37 x 2.65 160 x 187 x 67

Composite Grille UL 508 Type 12 TEP4UL12 4 0.4511

5.66144

0.7720

4.12105

6.39162

TFP42 6.29 x 7.37 x 2.65 160 x 187 x 67

Composite Grille UL 508 Type 1 TEP4 4 0.4511

5.66144

0.7720

4.12105

6.39162

TFP42SS 6.29 x 7.37 x 2.65 160 x 187 x 67

Stainless Steel Grille UL 508 Type 1 TEP4SS 4 0.4511

5.66144

0.7720

4.12105

6.39162

TFP42UL12 6.29 x 7.37 x 2.65 160 x 187 x 67

Composite Grille UL 508 Type 12 TEP4UL12 4 0.4511

5.66144

0.7720

4.12105

6.39162

TFP624 7.80 x 8.87 x 3.75 198 x 225 x 95

Composite Grille UL 508 Type 1 TEP6 6 0.4912

7.16182

1.3334

4.50114

7.89200

TFP61 7.80 x 8.87 x 3.75 198 x 225 x 95

Composite Grille UL 508 Type 1 TEP6 6 0.4912

7.16182

1.3334

4.50114

7.89200

TFP61SS 7.80 x 8.87 x 3.75 198 x 225 x 95

Stainless Steel Grille UL 508 Type 1 TEP6SS 6 0.4912

7.16182

1.3334

4.50114

7.89200

TFP61UL12 7.80 x 8.87 x 3.75 198 x 225 x 95

Composite Grille UL 508 Type 12 TEP6UL12 6 0.4912

7.16182

1.3334

4.50114

7.89200

TFP62 7.80 x 8.87 x 3.75 198 x 225 x 95

Composite Grille UL 508 Type 1 TEP6 6 0.4912

7.16182

1.3334

4.50114

7.89200

TFP62SS 7.80 x 8.87 x 3.75 198 x 225 x 95

Stainless Steel Grille UL 508 Type 1 TEP6SS 6 0.4912

7.16182

1.3334

4.50114

7.89200

TFP62UL12 7.80 x 8.87 x 3.75 198 x 225 x 95

Composite Grille UL 508 Type 12 TEP6UL12 6 0.4912

7.16182

1.3334

4.50114

7.89200

TFP101 11.81 x 12.99 x 5.25 300 x 330 x 133

Composite Grille UL 508 Type 1 TEP10 10 0.5514

11.16283

2.1454

6.88175

11.89302

TFP101SS 11.81 x 12.99 x 5.25 300 x 330 x 133

Stainless Steel Grille UL 508 Type 1 TEP10SS 10 0.5514

11.16283

2.1454

6.88175

11.89302

TFP101UL12 11.81 x 12.99 x 5.25 300 x 330 x 133

Composite Grille UL 508 Type 12 TEP10UL12 10 0.5514

11.16283

2.1454

6.88175

11.89302

TFP102 11.81 x 12.99 x 5.25 300 x 330 x 133

Composite Grille UL 508 Type 1 TEP10 10 0.5514

11.16283

2.1454

6.88175

11.89302

TFP102SS 11.81 x 12.99 x 5.25 300 x 330 x 133

Stainless Steel Grille UL 508 Type 1 TEP10SS 10 0.5514

11.16283

2.1454

6.88175

11.89302

TFP102UL12 11.81 x 12.99 x 5.25 300 x 330 x 133

Composite Grille UL 508 Type 12 TEP10UL12 10 0.5514

11.16283

2.1454

6.88175

11.89302

An intake grille and filter are included with each Cooling Fan Package. Order at least one Exhaust Package separately for each installation.

Order optional Exhaust Grilles as a separate accessory.

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 18: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

20

Networking:ThermalManagement

CoolingFanandExhaustPackageswithAccessories

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

 TechnicalPerformanceDataforCoolingFanPackagesCompositeGrilleULType1

StainlessGrilleULType1

Type1CFM@50/60Hz

CompositeGrilleULType12

Type12CFM@50/60Hz

W@50/60Hz Voltage

A@50/60Hz

Max.OperatingTemperature(°F)

Max.OperatingTemperature(°C)

NoiseSIL(dB)@50/60Hz

Weight(lb.)

Weight(kg)

TFP424 — 55 — — 8.4 24 VDC .35 158 70 65 4.2 1.90TFP41 TFP41SS 46/55 TFP41UL12 21/25 17/15 115 VAC .26/.21 158 70 37/41 4.2 1.90TFP42 TFP42SS 46/55 TFP42UL12 21/25 16/14 230 VAC .14/.11 158 70 37/41 4.3 1.95TFP624 — 140 — — 21.1 24 VDC .88 158 70 62.5 5.3 2.40TFP61 TFP61SS 117/140 TFP61UL12 50/60 36/32 115 VAC .45/.36 158 70 50/56 5.3 2.40TFP62 TFP62SS 117/140 TFP62UL12 50/60 39/35 230 VAC .23/.18 158 70 50/56 5.4 2.45TFP101 TFP101SS 180/215 TFP101UL12 63/75 64/80 115 VAC .58/.70 167 75 54/61 12.0 2.45TFP102 TFP102SS 180/215 TFP102UL12 63/75 64/80 230 VAC .29/.35 167 75 54/61 11.4 5.17

CFM with single exhaust grille installed.

OptionalGrillesandReplacementFilters OptionalgrillesofferthechoiceofstainlesssteelorblackABSplastic.ThesegrillesreplacethestandardRAL7035graycompositeorstainlesssteelgrillesonbothfanandexhaustpackages.Standardreplacementfiltersarewashablefoam(Type1)ordisposable(Type12).TomaintainULType12ratingontheenclosure,ULType12filtersmustbeusedonthefanpackageinlet.Washablealuminumfiltersarealsoavailable.AluminumfiltersarecompatiblewithType1systemsonly.Type 12 air filters are not washable.Bulletin:D85

CatalogNumber Description

FitsFanandExhaustNominalSize

FitsFanandExhaustGrillSize(in.)

FitsFanandExhaustGrilleSize(mm)

TG4SS Brushed stainless steel grille 4 6.29 x 7.31 x .81 (160 x 186 x 21)TG4B Black ABS plastic grille 4 6.29 x 7.37 x .81 (160 x 187 x 21)AFLTR4 Type 1 filter replacement (5/package) 4 — —AFLTR4AL Aluminum filter replacement (5/package) 4 — —TFLT4UL12 Type 12 filter replacement (5/package) 4 — —TG6SS Brushed stainless steel grille 6 7.80 x 8.81 x .75 (198 x 224 x 19)TG6B Black ABS plastic grille 6 7.80 x 8.87 x .49 (198 x 225 x 12)AFLTR6 Foam filter replacement (5/package) 6 — —AFLTR6AL Aluminum filter replacement (5/package) 6 — —TFLT6UL12 UL 12 filter replacement (5/package) 6 — —TG10SS Brushed stainless steel grille 10 11.81 x 12.92 x .75 (300 x 328 x 19)TG10B Black ABS plastic grille 10 11.81 x 12.99 x .75 (300 x 330 x 19)AFLTR10 Foam filter replacement (5/package) 10 — —AFLTR10AL Aluminum filter replacement (5/package) 10 — —TFLT10UL12 UL 12 filter replacement (5/package)a 10 — —

Replacement filter for Type 12 fan package only (models TFF__UL12). For Type 12 exhaust package use replacement filter AFLTRX.

Filters fit all fan and exhaust packages according to their size.

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 19: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

21

Networking:ThermalManagement

CoolingFanandExhaustPackageswithAccessories

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

EMCFan/GrilleUpgradeKitWiththeadditionofthiskit,thecoolingfanandexhaustpackagesareupgradedtoprovideEMC(electromagneticcompatibility)protection.ConsultHoffmanforshieldingeffectiveness(dBattenuationvs.frequency).Separate kits must be installed on both the inlet and outlet. Cooling fan and exhaust package must be ordered separately. EMC upgrade kit will not work with stainless steel grille option.Bulletin:D85

CatalogNumberFitsCoolingFanPackage

FitsExhaustGrille

T4EMC TFP41/TFP42 TEP4T6EMC TFP61/TFP62 TEP6T10EMC TFP101/TFP102 TEP10

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se

Page 20: Specifiers Guide Chapter 9: Networking - Free-Stand …...Networking: Thermal Management Air-to-Water Heat Exchanger Subject tochangewithoutnotice PH 763-422-2211 •FX 63-422-2600

22

Networking:ThermalManagement

FanShroudKit

Subjecttochangewithoutnotice PH763-422-2211•FX763-422-2600•hoffmanonline.com ©2011PentairTechnicalProducts

Fan Shroud Kit

FanShroudKit,Type3R

IndustryStandardsMaintainsUL/cULType3RratingwhenproperlyinstalledonaUL/cULType3Renclosure.UL508AListed;Type3R;FileNo.E61997cULListedperCSAC22.2No.94;Type3R;FileNo.E61997

NEMA/EEMACType3RIEC60529,IP22

ApplicationFanShroudKitsprotectoutdoorenclosureopeningsfromrain,sleetandsnow.

Features• Twofanshroudsperpackage• Perforatedventilationscreen• Pressure-sensitiveadhesive-backedgasketandmounting

hardware

Specifications• 16gaugemildsteelorType304stainlesssteel

FinishANSI61graypolyesterpowdercoatingovermildsteel;smooth#4brushedfinishonstainlesssteelBulletin:D85

StandardProduct CatalogNumber Material A(in.) A(mm) B(in.) B(mm) C1(in.) C1(mm) C2(in.) C2(mm) G(in.) G(mm) H(in.) H(mm)T4S3R Steel 6.00 152 6.00 152 1.44 37 4.69 119 4.69 119 5.25 133T6S3R Steel 8.00 203 8.00 203 1.44 37 4.69 119 6.69 170 7.25 184T10S3R Steel 12.00 305 12.00 305 1.44 37 4.71 120 10.69 272 11.25 286T4S3RSS Stainless Steel 6.00 152 6.00 152 1.44 37 4.69 119 4.69 119 5.25 113T6S3RSS Stainless Steel 8.00 203 8.00 203 1.44 37 4.69 119 6.69 170 7.25 184T10S3RSS Stainless Steel 12.00 305 12.00 305 1.44 37 4.71 120 10.69 272 11.25 286

 UsageChart

CatalogNumber

CompactCooling(muffin)Fans(4in.)

CompactCooling(muffin)Fans(6in.)

CompactCooling(muffin)Fans(10in.)

CoolingandExhaustFanPackages(TFP4-)

CoolingandExhaustFanPackages(TFP6-)

FilterFanPackages(SF05-)

FilterFanPackages(SF09-)

FilterFanPackages(SF10-)

T4S3R •T6S3R • • •T10S3R • • • • • • • •T4S3RSS •T6S3RSS • • •T10S3RSS • • • • • • • •

CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se