ELSEWEDY CABLES IN BRIEF
Elsewedy Cables was established in 1984 and is considered as one of the oldest and most successful industrial
and trading business groups across the Middle East and Africa in the elds of energ, plastics and contracting.Elsewed Cables is specialized mainl in Wires, Cables, Telecom Solutions, Electrical Products, Turnke Projects,and recentl Energ Generation. The groups turnover has been rapidl rising during the past few ears to reach$ 1.5 billion in 2007, also, the production capacit is the second highest one in the region, with 125000 tons/annum, expecting 212000 tons/annum in 2008.
Although the compan began as an Egptian local manufacturer, it has branched out regionall andinternationall to include 23 production facilities for cables and electrical products that are located in 12 contries(Egpt, Sudan, Algeria, Zambia, Ghana, Sria, Saudi Arabia, Qatar, Slovenia, India and Malasia), and it currentlexport its wide range of high qualit and safe products to more than 110 countries worldwide. Additionall, thegroups outstanding human potential, which is more than 5000 emploees, and its solid nancial postioin, alongwith the strong geographical prsensce, have heavil contributed to the groups success and prosperit.
To strengthen its position world wide, and following the corporate strateg, on the one hand, Elsewed Cablesfull acquired b the end of 2007 ISKRAEMECO, a leader manufacturer of electrometers and currentl the third
largest plaer in the European market and the seventh largest globall; on the other hand, Elsewed Cables isinvolved with 74% ownership jointl with Glencore International in a 850 $US million project for the construction ofa copper smelter to be located in Egpt.
8/8/2019 Special Cables Catalogue - El Sewedy Cables
3/126
ELSEWEDY CABLES IN BRIEF
Further more, Elsewed Cables provides a complete portfolio of solutions and advanced technologies for sectorsas diverse as the automotive and aerospace industries, railwas, buildings, telecommunication and energnetworks, oil and gas, submarine power sstems, etc. Accordingl, Elsewed Cables is divided in three segmentsin order to cover all those sectors: Wires & cables, electrical products, and turn-ke projects. The group hasobtained qualit certicates from the most reputable laboratories, among them: ISO 90012000-, ISO 14001, QS9000, KEMA.a
Qualit and safet are so much considered. Elsewed Cables adopted a polic that assures maximum effectivenessand efcienc through processes and sstems ensuring that ever aspect of each compans activit is alignedto satisf customer needs and all other objectives without wasting effort and with the use of the full potential ofever person. Our organizational philosoph believes that customer satisfaction, health, safet, environmentalconsiderations, and business objectives are mutuall dependent.
In the industrial sector, we currentl suppl approximatel 56% of Egpts global market share of power cables,
telecommunication cables, and lighting industries. In the export sector, as part of a worldwide marketing plan,Elsewed Cables has branches throughout Africa, Middle East, Gulf Area, Europe, and Asia, and consistentlshowing dramatic increases; Egpt enjos an important number of trade agreements with most of those countries(EU Agreement, Arab Free Trade Agreement, COMESA Agreement). Nowadas, Elsewed Cables is exportingapproximatel 60% of its total turnover (export value of 550 $US million in 2006, 1 $US billion in 2007). For that reason,the group is concentrating efforts and making investments to target market segments and countries world widewith strong growth potential, such as Europe, Asia, or Latin America, although strengthen its leadership in Africaand Middle East.
Elsewed Cables mission is to become world expert in cables, with a strong nancial basis and technicaladvanced product portfolio, making it an attractive partner for all its stakeholders: Shareholders, customers,suppliers, and emploees.
8/8/2019 Special Cables Catalogue - El Sewedy Cables
4/126
GROUP HISTORy1938 Elsewed famil started its business as a trader in electrical equipment.
1960 The business was developed further b turning into a distributor for the onl cables manufacturing atthat time.
1984 Based on their experience in that field, the famil decided to build Egpts first private sector cablesfactor ARAB CABLES.
1986 Arab Cables started production as Egpts and the Middle Easts private sector cables supplier.
1986-96 Arab Cables capacit quadruples from around 6.000 tons of copper cables in 1986 to 30.000tons in 1996.
1996 Elsewed famil established their second factor, EGyTECH CABLES, which is the most advancedcables production facilit in the Middle East with an annual capacit of 30.000 tons of coppercables and 15.000 tons of aluminum cables.
Elsewed famil established their first plant for producing PVC compounds and master batch forcables insulation SEDPLAST considered as major component for the production of cables.
1997 Elsewed famil established UNITED INDUSTRIES, the compan consists of three different factoriesspecialized in the production of special cables (first factor in Egpt), winding wires & fiber glasspoles.
Elsewed famil established ELASTIMOLD EGyPT, as a joint venture with ELastimold, a unit ofThomas & Betts, one of the leading companies worldwide in the field of cables accessories, toproduce power cable joints and Modular Terminators.
1998 Elsewed famil established UNITED METALS CO. Egpts first factor to produce High GradeCopper Rods, the main component in the production of cables conductors. The factor isconsidered as the largest copper rod factor in the Middle East region.
Elsewed famil established Elsewed SEDCO, as the first and onl factor in Africa and the
Middle East producing cable accessories.
2002 Elsewedy Cables established their first cables factory outside Egypt GIAD Elsewedy Cablesin partnership with the Sudanese compan Giad for the production of power cables, over headconductors and telephone cables.
2003 Elsewed Cables further enhances their facilities outside Egpt b establishing the SUDANESEEGyPTAION ELECTRICAL INDUSTRIES CO. in partnership with Sudanese electricit authorit.SUDATRAF (specialized in manufacturing transformers, electrical panels & cables joint andterminators).
2004 Together Elsewed Cables Group & Italsmea compan (Ital) established a joint venture for themanufactor of explosion proof electrical equipment. Italsmea Elsewed co.
2005 Elsewed Cables established the Srias latest cables factor Elsewed Cables SyRIA specialized
in power cables manufacturing up to 400 kV, reling on the growth in the area of: Sria, Lebanon,Jordan, Iraq, Iran, Palestine and all Arab countries near b.
2006 Elsewed Cables penetrated Ghana, b establishing Elsewed ELECTRIC-GHANA the factor isspecialized in Fiber Glass Road Lighting Poles manufacturing.
2007 Elsewed Cables established two new factories:
Elsewed Cables SAUDI ARABIA specialized in wires and cables.
Elsewed ELECTRIC SyRIA specialized in transformers.
Acquisition of ISKRAEMECO specialized in energ measurement & management sstems.
2008 Elsewed Cables established two new factories:
Elsewed Cables QATAR: specialized in power cables Low & Medium.
Elsewedy Cables ALGERIA: specialized in power cables Low & Medium in addition
to instrumentation cables.
8/8/2019 Special Cables Catalogue - El Sewedy Cables
5/126
GROUP STRUCTURE
Wires & Cables
Electrical Products
Turnke Projects
PSPElsewedy
Power SstemsProjects
UnitedMetals
SEDCO
Sedplast
Egyplast
UnitedWires
Red Sea
Copper
ArabCables
EgytechCables
Giad ElsewedyCables
ElsewedyCables Syria
ElsewedyCables
Saudi Arabia
LibyaCables
ElsewedyCablesEgypt
ElsewedyCablesAlgeria
ElsewedyElectric
Transmission &Distribution
ElastimoldEgypt
ElsewedyTransformers
Egypt
Elsewedy ElectricSyria
ElsewedyElectric Zambia
United
Industries
SudaneseEgyptian Electrical
Industries
ElsewedyElectric Ghana
ISKRAEMECO
8/8/2019 Special Cables Catalogue - El Sewedy Cables
6/126
index
A Instrumentation Cables
B Fire Resistant & Fire Alarm Cables
C Control Cables
D Lan and Telephone Cables
E Coaxial Cables
F Automotive Wires
G Appliance Cables and Cords
H Technical Information
I Glossary
J Certicates
8/8/2019 Special Cables Catalogue - El Sewedy Cables
7/126
High
ResolutionPls
8/8/2019 Special Cables Catalogue - El Sewedy Cables
8/126
8/8/2019 Special Cables Catalogue - El Sewedy Cables
9/126
A. instrumentaton
CablesPVC Insulation, Multipairs, Twisted in Bundles, Collective Screen...............................................................
PVC Insulation, Single Pair or Triple, Collective Screen................................................................................
PVC Insulation, Multipairs, Laers, Collective Screen...................................................................................
PVC Insulation, Multipairs, Layers, Individual and Collective Screen............................................................
PVC Insulation, Multitriples, Layers, Collective Screen....................................................................................
PVC Insulation, Multitriples, Layers, Individual and Collective Screen...........................................................
PVC Insulation, Single Pair, Collective Screen, Galvanized Steel Wire Armour.............................................
PVC Insulation, Multipairs, Layers, Collective Screen, Galvanized Steel Wire Armour..................................
PVC Insulation, Individual and Collective screen, Galvanized Steel wire Armour...........................................
PVC Insulation, Multipairs, Layers, Individual and Collective Screen, Galvanized Steel Wire Armour..........
PE Insulation, Multipairs, Twisted in Bundles, Collective Screen......................................................................
PE Insulation, Single Pair or Triple, Collective Screen...................................................................................PE Insulation, Multipairs, Layers, Collective Screen.........................................................................................
PE Insulation, Multipairs, Layers, Individual and Collective Screen................................................................
PE Insulation, Multitriples, Layers, Collective Screen.......................................................................................
PE Insulation, Multitriples, Layers, Individual and Collective Screen..............................................................
PE Insulation, Single Pair, Collective Screen, Galvanized Steel Wire Armour..................................................
PE Insulation, Multipairs, Layers, Collective Screen, Galvanized Steel Wire Armour......................................
PE Insulation, Multipairs, Layers, Collective Screen Galvanized Steel Wire Armour.......................................
PE Insulation, Multipairs, Layers, Individual and Collective Screen, Galvanized Steel Wire Armour...........
PE Insulation, Multicores, Layers, Overall Screen of Tinned Copper Wire Braid.............................................
PE Insulation, Single Pair, Collective Screen of Tinned Copper Wire Braid.....................................................
PE Insulation, Multipairs, Laers, Overall Screen of Tinned Copper Wire Braid.........................................PE Insulation, Multipairs, Laers, Overall Screen of Plain or Tinned Copper Wire Braid...........................
2
34
6
8
10
12
13
15
16
17
1819
21
23
25
27
28
29
30
32
33
3435
8/8/2019 Special Cables Catalogue - El Sewedy Cables
10/126
A 2
Conductor
size
Number
of
pairs
Conductor Nominalinsulationthickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weight
UIC - codeNo.x dia.
Max. DCRes. At20oC
mm2 No.No. xmm
Ohm /Km mm mm mm Kg/Km -
0.5
2 7 x 0.3 39.2 0.6 1.0 7.9 80 CPC-T1202-JU05GQ
4 7 x 0.3 39.2 0.6 1.0 10.1 100 CPC-T1204-JU05GQ
8 7 x 0.3 39.2 0.6 1.0 12.1 160 CPC-T1208-JU05GQ
12 7 x 0.3 39.2 0.6 1.2 14.4 230 CPC-T1212-JU05GQ
16 7 x 0.3 39.2 0.6 1.2 16.1 300 CPC-T1216-JU05GQ
20 7 x 0.3 39.2 0.6 1.2 18.5 360 CPC-T1220-JU05GQ
24 7 x 0.3 39.2 0.6 1.4 20.3 450 CPC-T1224-JU05GQ
1.0
2 7 x 0.43 18.4 0.6 1.0 8.9 100 CPC-T1202-JU12GQ
4 7 x 0.43 18.4 0.6 1.0 12 160 CPC-T1204-JU12GQ
8 7 x 0.43 18.4 0.6 1.2 16 300 CPC-T1208-JU12GQ
12 7 x 0.43 18.4 0.6 1.4 20 430 CPC-T1212-JU12GQ
16 7 x 0.43 18.4 0.6 1.4 22 550 CPC-T1216-JU12GQ
20 7 x 0.43 18.4 0.6 1.4 24.3 660 CPC-T1220-JU12GQ
24 7 x 0.43 18.4 0.6 1.6 26.7 800 CPC-T1224-JU12GQ
TECHNICAL INFORMATION
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specic request.
Multipairs, Twisted in Bundles, Collective Screen
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmissionof analogue and digital signals for measurements and process control purposes.
Engineering Specication:
Standard:BS 5308-2
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polvinlchloride TI1 to BS 6746
Assembly:Cores twisted to form pairs, 4 pairs twisted toform a bundle, bundles twisted in concentriclaers, 2 pairs twisted as star quad
Colour code:One Pair : Blue / RedTwo Pairs : Gre / yellowThree Pairs : Green / BrownFour Pairs : White / BlackBundles are identied b coloured polestertapes.
Wrappng:Polester tapes
Collectve Screen:Aluminum polyester tape with tinned drain wire andwrapped by polyester tapes
Sheath:Polvinlchloride TM1 to BS 6746 colour black or greor blue
Mnmum bendng radus:7.5*d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operaion
Packng:On non-returnable wooden drums
PVC Insulation
UICE
lsewedyInstrumentationCables225V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
11/126
A 3
Cable Size
ConductorNominalinsulation
thickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weight
UIC - code
No.x dia.
Max. DC
Res. At20
oC
mm2 No. x mm Ohm /Km mm mm mm Kg/Km -
1x 2 x 0.5 7 x 0.3 39.2 0.6 0.8 6.0 50 CPC-T1201-JU05B
1x 3 x 0.5 7 x 0.3 39.2 0.6 0.8 6.3 60 CPC-T1301-JU05B
1x 2 x 0.75 7 x 0.37 24.6 0.6 0.8 6.4 60 CPC-T1201-JU08B
1x 3 x 0.75 7 x 0.37 24.6 0.6 0.8 6.7 70 CPC-T1301-JU08B
1x 2 x 1.0 7 x 0.43 18.4 0.6 0.8 6.8 70 CPC-T1201-JU12B
1x 3 x 1.0 7 x 0.43 18.4 0.6 0.8 7.1 80 CPC-T1301-JU12B
1x 2 x 1.3 7 x 0.49 14.2 0.6 0.8 7.1 80 CPC-T1201-JU14B
1x 3 x 1.3 7 x 0.49 14.2 0.6 0.8 7.4 90 CPC-T1301-JU14B
1x 2 x 1.5 7 x 0.53 12.6 0.6 0.8 7.6 90 CPC-T1201-JU15B
1x 3 x 1.5 7x 0.53 12.6 0.6 0.8 8.0 110 CPC-T1301-JU15B
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specic request.
Single Pair or Triple, Collective Screen
Applcaton:These cables are used in the chemical and petrochemical industries for the transmission of analogueand digital signals for measurements and process control purposes.
Engineering Specication:
Standard:BS 5308-2
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polvinlchloride TI1 to BS 6746
Assembly:cores twisted to form a pair or triple andwrapped by polyester tapes
Colour code:Pair : White / BlackTriple : Black / White / Red
Screen:Collective screen aluminum polester tape withtinned drain wire and wrapped by polyester tapes
Sheath:Polvinlchloride TM1 to BS 6746 colour black or greor blue
Mnmum bendng radus:7.5*d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operaion
Packng:On non-returnable wooden drums
TECHNICAL INFORMATION
PVC Insulation
UICE
lsewe
dy
Ins
trumen
tation
Ca
bles
300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
12/126
A 4
Conductor
size
Number
ofpairs
ConductorNominal
insulationthickness
Nominal
sheaththickness
Approximate
overalldiameter
Approximate
netweight
UIC - codeNo.x dia.
Max. DC Res.At 20oC
mm2 No.No. xmm
Ohm /Km mm mm mm Kg/Km -
0.5
2 7 x 0.3 39.2 0.6 1.0 9.3 107 CPC-T1202-JU05B
4 7 x 0.3 39.2 0.6 1.0 10.0 117 CPC-T1204-JU05B
8 7 x 0.3 39.2 0.6 1.2 13.2 199 CPC-T1208-JU05B
12 7 x 0.3 39.2 0.6 1.2 15.0 265 CPC-T1212-JU05B
16 7 x 0.3 39.2 0.6 1.2 16.7 340 CPC-T1216-JU05B
20 7 x 0.3 39.2 0.6 1.3 18.7 410 CPC-T1220-JU05B
24 7 x 0.3 39.2 0.6 1.3 20.6 480 CPC-T1224-JU05B
30 7 x 0.3 39.2 0.6 1.5 23.3 685 CPC-T1230-JU05B
0.75
2 7 x 0.37 24.6 0.6 1.0 10.1 125 CPC-T1202-JU08B
4 7 x 0.37 24.6 0.6 1.0 10.8 140 CPC-T1204-JU08B
8 7 x 0.37 24.6 0.6 1.2 14.3 245 CPC-T1208-JU08B
12 7 x 0.37 24.6 0.6 1.2 16.3 330 CPC-T1212-JU08B
16 7 x 0.37 24.6 0.6 1.3 18.3 430 CPC-T1216-JU08B
20 7 x 0.37 24.6 0.6 1.3 20.3 520 CPC-T1220-JU08B
24 7 x 0.37 24.6 0.6 1.3 22.5 610 CPC-T1224-JU08B
30 7 x 0.37 24.6 0.6 1.5 23.3 720 CPC-T1230-JU08B
Multipairs, Laers, Collective Screen
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogueand digital signals for measurements and process control purposes.
TECHNICAL INFORMATION
PVC Insulation
Engineering Specication:
Standard:BS 5308-2
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polvinlchloride TI1 to BS 6746
Assembly:Cores twisted to form pairs, twisted pairs inconcentric layers and wrapped by polyestertapes
Colour code:Black / White, continuousl numbered, oridentication tapes numbered
Collectve Screen:Aluminiumpolystertapewithtinneddrainwire and wrapped by polyester tapes
Sheath:Polvinlchloride TM1 to BS 6746 colourblack or gre or blue
Mnmum bendng radus:7.5 x d (d= overall diameter)
Temperature ratng:+5oC up to + +50oC during operation
Packng:On non-returnable wooden drums
UIC
Elsewe
dy
Ins
trumen
tation
Ca
bles
300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
13/126
8/8/2019 Special Cables Catalogue - El Sewedy Cables
14/126
A 6
Conductorsize
Numberof
pairs
ConductorNominalinsulationthickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weight
UIC - codeNo.x dia.
Max. DCRes. At
20oC
mm2 No.No. xmm
Ohm /Km mm mm mm Kg/Km -
0.5
2 7 x 0.3 39.2 0.6 1.0 10.3 122 CPC-T1202-SU05B
4 7 x 0.3 39.2 0.6 1.0 11.1 140 CPC-T1204-SU05B
8 7 x 0.3 39.2 0.6 1.2 14.7 240 CPC-T1208-SU05B
12 7 x 0.3 39.2 0.6 1.3 17.0 340 CPC-T1212-SU05B
16 7 x 0.3 39.2 0.6 1.3 18.9 433 CPC-T1216-SU05B
20 7 x 0. 3 39.2 0.6 1.3 21.0 518 CPC-T1220-SU05B24 7 x 0. 3 39.2 0.6 1.5 23.7 636 CPC-T1224-SU05B
30 7 x 0. 3 39.2 0.6 1.5 26.3 867 CPC-T1230-SU05B
0.75
2 7 x 0.37 24.6 0.6 1.0 11.2 149 CPC-T1202-SU08B
4 7 x 0.37 24.6 0.6 1.0 11.9 165 CPC-T1204-SU08B
8 7 x 0.37 24.6 0.6 1.2 15.8 291 CPC-T1206-SU08B
12 7 x 0.37 24.6 0.6 1.3 18.3 409 CPC-T1208-SU08B
16 7 x 0.37 24.6 0.6 1.3 20.4 523 CPC-T1212-SU08B
20 7 x 0.37 24.6 0.6 1.3 22.8 631 CPC-T1216-SU08B
24 7 x 0.37 24.6 0.6 1.5 25.7 770 CPC-T1220-SU08B
30 7 x 0.37 24.6 0.6 1.7 26.4 902 CPC-T1230-SU08B
Multipairs, Layers, Individual and Collective Screen
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogue anddigital signals for measurements and process control purposes.
Engineering Specication:
Standard:BS 5308-2
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polvinlchloride TI1 to BS 6746
Assembly:Cores twisted to form pairs, pairs screenedb aluminum polester tape, screened pairstwisted in concentric laers, and wrapped bpolyester tapes
Screen:Collective screen of aluminum polestertape with tinned drain wire and wrapped bypolyester tapes
Sheath:Polvinlchloride TM1 to BS 6746 colour black or blue
Mnmum bendng radus:7.5 x d (d= overall diameter)
Temperature ratng:+5oC up to +50oC during operaion
Packng:On non-returnable wooden drums
TECHNICAL INFORMATION
PVC Insulation
UICElsewedyInstrumentationCables300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
15/126
A 7
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
Conductorsize
Numberof
pairs
ConductorNominalinsulationthickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weightUIC - code
No.x dia.Max. DCRes. At20oC
mm2 No.No. xmm
Ohm /Km mm mm mm Kg/Km -
1.0
2 7 x 0.43 18.4 0.6 1.2 12.2 172 CPC-T1202-SU12B
4 7 x 0.43 18.4 0.6 1.2 13.1 201 CPC-T1204-SU12B
8 7 x 0.43 18.4 0.6 1.3 17.2 351 CPC-T1208-SU12B
12 7 x 0.43 18.4 0.6 1.3 19.7 486 CPC-T1212-SU12B
16 7 x 0.43 18.4 0.6 1.3 21.9 626 CPC-T1216-SU12B
20 7 x 0.43 18.4 0.6 1.5 25.0 670 CPC-T1220-SU12B
24 7 x 0.43 18.4 0.6 1.5 27.6 923 CPC-T1224-SU12B
30 7 x 0.43 18.4 0.6 1.7 30.5 1253 CPC-T1230-SU14B
1.3
2 7 x 0.49 14.2 0.6 1.2 12.8 195 CPC-T1202-SU14B
4 7 x 0.49 14.2 0.6 1.3 14.0 245 CPC-T1204-SU14B
8 7 x 0.49 14.2 0.6 1.3 18.2 425 CPC-T1208-SU14B
12 7 x 0.49 14.2 0.6 1.3 20.3 615 CPC-T1212-SU14B
16 7 x 0.49 14.2 0.6 1.5 23.2 790 CPC-T1216-SU14B
20 7 x 0.49 14.2 0.6 1.5 27.0 880 CPC-T1220-SU14B
24 7 x 0.49 14.2 0.6 1.7 31.2 1100 CPC-T1224-SU14B
30 7 x 0.49 14.2 0.6 2.0 34.5 1450 CPC-T1230-SU14B
1.5
2 7 x 0.53 12.6 0.6 1.2 14.1 228 CPC-T1202-SU15B
4 7 x 0.53 12.6 0.6 1.2 15.4 273 CPC-T1204-SU15B
8 7 x 0.53 12.6 0.6 1.3 20.3 480 CPC-T1208-SU15B
12 7 x 0.53 12.6 0.6 1.5 24.0 700 CPC-T1212-SU15B
16 7 x 0.53 12.6 0.6 1.5 26.7 904 CPC-T1216-SU15B
20 7 x 0.53 12.6 0.6 1.7 30.2 1119 CPC-T1220-SU15B
24 7 x 0.53 12.6 0.6 2.0 34.0 1370 CPC-T1224-SU15B
30 7 x 0.53 12.6 0.6 2.2 37.4 1845 CPC-T1230-SU15B
TECHNICAL INFORMATION
PVC InsulationMultipairs, Layers, Individual and Collective Screen
8/8/2019 Special Cables Catalogue - El Sewedy Cables
16/126
A 8
Conductorsize
Numberof
triples
Conductor Nominalinsulationthickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weight
UIC - codeNo.xdia.
Max. DCRes.
At 20oC
mm2 No.No. xmm
Ohm/Km mm mm mm
Kg/Km -
0.5
2 7 x 0.3 39.2 0.6 1.0 10.1 125 CPC-T1302-JU05B
4 7 x 0.3 39.2 0.6 1.0 10.8 150 CPC-T1304-JU05B
8 7 x 0.3 39.2 0.6 1.2 14.6 245 CPC-T1308-JU05B
12 7 x 0.3 39.2 0.6 1.3 16.5 347 CPC-T1312-JU05B
16 7 x 0.3 39.2 0.6 1.3 18.7 450 CPC-T1316-JU05B
20 7 x 0.3 39.2 0.6 1.3 21.2 565 CPC-T1320-JU05B
24 7 x 0.3 39.2 0.6 1.5 24.0 670 CPC-T1324-JU05B30 7 x 0.3 39.2 0.6 1.5 27.7 975 CPC-T1330-JU05B
0.75
2 7 x 0.37 24.6 0.6 1.0 10.9 145 CPC-T1302-JU08B
4 7 x 0.37 24.6 0.6 1.0 11.8 190 CPC-T1304-JU08B
8 7 x 0.37 24.6 0.6 1.3 15.9 375 CPC-T1308-JU08B
12 7 x 0.37 24.6 0.6 1.3 17.9 435 CPC-T1312-JU08B
16 7 x 0.37 24.6 0.6 1.3 20.2 535 CPC-T1316-JU08B
20 7 x 0.37 24.6 0.6 1.5 23.8 675 CPC-T1320-JU08B
24 7 x 0.37 24.6 0.6 1.5 26.0 970 CPC-T1324-JU08B
30 7 x 0.37 24.6 0.6 1.7 30.0 1175 CPC-T1330-JU08B
Multitriples, Layers, Collective Screen
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogue anddigital signals for measurements and process control purposes.
Engineering Specication:
Standard:BS 5308-2
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polvinlchloride TI1 to BS 6746
Assembly:Cores twisted to form triples, twisted triples inconcentric laers, and wrapped b polestertapes.
Colour code:Black / White / Red, continuousl numbered,or identication tapes numbered
Wrappng:Polester tapes
Collectve ScreenAluminum polyester tape with tinned drain wire and
wrapped by polyester tapes
Sheath:Polvinlchloride TM1 to BS 6746 colour black or greor blue
Mnmum bendng radus:7.5 x d (d= overall diameter)
Temperature ratng:+5oC up to +50oC during operation
Packng:On non-returnable wooden drums
TECHNICAL INFORMATION
PVC Insulation
UICElsewe
dy
Ins
trumen
tation
Ca
bles
300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
17/126
A 9
Conductorsize
Numberof
triples
ConductorNominalinsulation
thickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weightUIC codeNo.x
dia.
Max. DCRes. At20oC
mm2 No.No. xmm
Ohm /Km mm mm mm Kg/Km -
1.0
2 7 x 0.43 18.4 0.6 1.2 12.1 170 CPC-T1302-JU12G
4 7 x 0.43 18.4 0.6 1.2 13.6 255
8 7 x 0.43 18.4 0.6 1.3 17.6 430 CPC-T1308-JU12G
12 7 x 0.43 18.4 0.6 1.3 20.3 590
16 7 x 0.43 18.4 0.6 1.3 22.8 750 CPC-T1316-JU12G
20 7 x 0.43 18.4 0.6 1.5 25.6 930
24 7 x 0.43 18.4 0.6 1.5 27.6 1090 CPC-T1324-JU12G
30 7 x 0.43 18.4 0.6 1.7 33.2 1325
1.3
2 7 x 0.49 14.2 0.6 1.2 12.8 200 CPC-T1302-JU14G
4 7 x 0.49 14.2 0.6 1.3 14.4 295
8 7 x 0.49 14.2 0.6 1.3 18.8 510 CPC-T1308-JU14G
12 7 x 0.49 14.2 0.6 1.3 21.7 710
16 7 x 0.49 14.2 0.6 1.5 25.0 930 CPC-T1316-JU14G
20 7 x 0.49 14.2 0.6 1.5 27.4 1130
24 7 x 0.49 14.2 0.6 1.7 29.6 1335 CPC-T1324-JU14G
30 7 x 0.49 14.2 0.6 2.0 34.6 1630
1.5
2 7 x 0.53 12.6 0.6 1.2 14.0 230 CPC-T1302-JU15G
4 7 x 0.53 12.6 0.6 1.3 15.9 325
8 7 x 0.53 12.6 0.6 1.3 20.8 570 CPC-T1308-JU15G
12 7 x 0.53 12.6 0.6 1.5 24.8 810
16 7 x 0.53 12.6 0.6 1.5 27.9 1120 CPC-T1316-JU15G
20 7 x 0.53 12.6 0.6 1.7 30.7 1280
24 7 x 0.53 12.6 0.6 2.0 33.1 1515 CPC-T1324-JU15G
30 7 x 0.53 12.6 0.6 2.2 37.3 1960
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
TECHNICAL INFORMATION
PVC InsulationMultitriples, Layers, Collective Screen
8/8/2019 Special Cables Catalogue - El Sewedy Cables
18/126
A 10
Conductorsize
Numberof
triples
ConductorNominalinsulationthickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weight
UIC codeNo.x dia.
Max. DCRes. At20oC
mm2 No.No. xmm
Ohm /Km mm mm mm Kg/Km -
0.5
2 7 x 0.3 39.2 0.6 1.0 11.7 150 CPC-T1302-JU05B
4 7 x 0.3 39.2 0.6 1.2 13.2 205 CPC-T1304-JU05B
8 7 x 0.3 39.2 0.6 1.3 17.0 335 CPC-T1308-JU05B
12 7 x 0.3 39.2 0.6 1.3 19.6 450 CPC-T1312-JU05B
16 7 x 0.3 39.2 0.6 1.3 22.0 575 CPC-T1316-JU05B
20 7 x 0.3 39.2 0.6 1.5 24.7 710 CPC-T1320-JU05B
24 7 x 0.3 39.2 0.6 1.5 26.6 835 CPC-T1324-JU05B
30 7 x 0.3 39.2 0.6 1.7 29.2 1130 CPC-T1330-JU05B
0.75
2 7 x 0.37 24.6 0.6 1.0 12.5 165 CPC-T1302-JU08B
4 7 x 0.37 24.6 0.6 1.2 14.1 235 CPC-T1304-JU08B
8 7 x 0.37 24.6 0.6 1.3 18.3 395 CPC-T1308-JU08B
12 7 x 0.37 24.6 0.6 1.3 21.1 550 CPC-T1312-JU08B
16 7 x 0.37 24.6 0.6 1.5 24.2 720 CPC-T1316-JU08B
20 7 x 0.37 24.6 0.6 1.7 26.7 875 CPC-T1320-JU08B
24 7 x 0.37 24.6 0.6 1.7 28.8 1030 CPC-T1324-JU08B
30 7 x 0.37 24.6 0.6 2.0 32.4 1325 CPC-T1330-JU08B
Multitriples, Layers, Individual and Collective Screen
TECHNICAL INFORMATION
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogueand digital signals for measurements and process control purposes.
Engineering Specication:
Standard:BS 5308-2
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polvinlchloride TI1 to BS 6746
Assembly:Cores twisted to form triples, triples screenedb aluminum polester tapes, screened triplestwisted in concentric laers, and wrapped bpolyester tapes
Colour code:Black / White / Red, continuousl numbered,or identication tapes numbered
Wrappng:Polester tapes
Collectve ScreenAluminum polyester tape with tinned drain wireand wrapped by polyester tapes
Sheath:Polvinlchloride TM1 to BS 6746 colour black or
grey or blue
Mnmum bendng radus:7.5 x d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operation
Packng:On non-returnable wooden drums
PVC Insulation
UICElsewedyInstrumentationCables300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
19/126
A 11
Conductorsize
Numberof
Triples
Conductor Nominalinsulationthickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weight
UIC codeNo.x dia.
Max. DCRes. At20oC
mm2 No.No. xmm
Ohm /Km mm mm mm Kg/Km -
1.0
2 7 x 0.43 18.4 0.6 1.2 13.7 195 CPC-T1302-SU12B
4 7 x 0.43 18.4 0.6 1.3 15.5 285 CPC-T1304-SU12B
8 7 x 0.43 18.4 0.6 1.3 20.3 480 CPC-T1308-SU12B
12 7 x 0.43 18.4 0.6 1.5 23.5 665 CPC-T1312-SU12B
16 7 x 0.43 18.4 0.6 1.5 27.1 880 CPC-T1316-SU12B
20 7 x 0.43 18.4 0.6 1.7 29.8 1060 CPC-T1320-SU12B
24 7 x 0.43 18.4 0.6 1.7 32.2 1250 CPC-T1324-SU12B
30 7 x 0.43 18.4 0.6 2.0 35.3 1530 CPC-T1330-SU14B
1.3
2 7 x 0.49 14.2 0.6 1.3 14.4 230 CPC-T1302-SU14B
4 7 x 0.49 14.2 0.6 1.3 16.4 330 CPC-T1304-SU14B
8 7 x 0.49 14.2 0.6 1.3 21.6 565 CPC-T1308-SU14B
12 7 x 0.49 14.2 0.6 1.5 25.6 810 CPC-T1312-SU14B
16 7 x 0.49 14.2 0.6 1.7 28.9 1050 CPC-T1316-SU14B
20 7 x 0.49 14.2 0.6 1.7 31.8 1270 CPC-T1320-SU14B
24 7 x 0.49 14.2 0.6 2.0 35.4 1525 CPC-T1324-SU14B
30 7 x 0.49 14.2 0.6 2.2 37.2 1730 CPC-T1330-SU14B
1.5
2 7 x 0.53 12.6 0.6 1.3 15.2 265 CPC-T1302-SU15B
4 7 x 0.53 12.6 0.6 1.3 17.3 365 CPC-T1304-SU15B
8 7 x 0.53 12.6 0.6 1.3 22.9 610 CPC-T1308-SU15B
12 7 x 0.53 12.6 0.6 1.5 27.2 935 CPC-T1312-SU15B
16 7 x 0.53 12.6 0.6 1.7 30.7 1180 CPC-T1316-SU15B
20 7 x 0.53 12.6 0.6 2.0 33.8 1430 CPC-T1320-SU15B
24 7 x 0.53 12.6 0.6 2.2 37.0 1710 CPC-T1324-SU15B
30 7 x 0.53 12.6 0.6 2.2 40.6 2200 CPC-T1330-SU15B
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
TECHNICAL INFORMATION
PVC InsulationMultitriples, Layers, Individual and Collective Screen
8/8/2019 Special Cables Catalogue - El Sewedy Cables
20/126
A 12
Conductorsize
Numberof
pairs
ConductorNominalinsulationthickness
steel wirediameter
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weightUIC codeNo.x
dia.
Max.DC Res.At 20oC
mm2 No.No. xmm
Ohm/Km
mm mm mm mm Kg/Km -
0.5 1 7 x 0.3 39.2 0.6 0.8 1.3 10.7 219 CPC-T1201-JM05B
0.75 1 7 x 0.37 24.6 0.6 0.8 1.3 11.0 240 CPC-T1201-JM08B
1.0 1 7 x 0.43 18.4 0.6 0.8 1.3 11.4 255 CPC-T1201-JM12B
1.3 1 7 x 0.49 14.2 0.6 0.8 1.4 11.8 275 CPC-T1201-JM14B
1.5 1 7 x 0.53 12.6 0.6 0.8 1.4 12.6 300 CPC-T1201-JM15B
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
Single Pair, Collective Screen , Galvanized Steel Wire Armour
TECHNICAL INFORMATION
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogueand digital signals for measurements and process control purposes, where mechanical damages areexpected to occur.
Engineering Specication:
Standard:BS 5308-2
Rated Voltage:300/500 V
Conductor:
Stranded annealed plain copper
insulaton:Polvinlchloride TI1 to BS 6746
Assembly:cores twisted to form a pair and screened by
Aluminum Polester tape with tinned drainwire and wrapped by polyester tapes
Colour code:Black / White
Screen:Collective screen of aluminium polester tapes withtinned drain wire and wrapped by polyester tapes
Beddng:Polvinlchloride
Armourng;Galvanized steel wire armour to BS 1442
Sheath:Polvinlchloride TM1 to BS 6746 colour black or blue
Mnmum bendng radus:10 x d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operation
Packng:On non-returnable wooden drums
PVC Insulation
UICElsewe
dy
Ins
trumen
tation
Ca
bles
300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
21/126
A 13
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogueand digital signals for measurements and process control purposes, where mechanical damages areexpected to occur.
Engneerng Specfcaton:
Standard:BS 5308-2
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polvinlchloride TI1 to BS 6746
Assembly:Cores twisted to form a pairs, pairs twistedin concentric layers and wrapped bypolyester tapes
Colour code:Black / White continuouslnumbered, or identication tapesnumbered
Screen:Collective screen of aluminium polester tape withtinned drain wire and wrapped by polester tapes
Beddng:Polvinlchloride
Armourng;Galvanized steel wire armour to BS 1442
Sheath:Polvinlchloride TM1 to BS 6746 colour black or blue
Mnmum bendng radus:10 x d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operation
Packng:On non-returnable wooden drums
Conductorsize
Numberof
pairs
Conductor
Nominalinsulationthickness
steel wirediameter
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weightUIC code
No.xdia.
Max.DC
Res. At20oC
mm2 No. No. xmmOhm/Km mm mm mm mm Kg/Km -
0.5
2 7 x 0.3 39.2 0.6 0.8 1.4 13.5 344 CPC-T1202-JM05B
4 7 x 0.3 39.2 0.6 0.8 1.4 14.6 395 CPC-T1204-JM05B
8 7 x 0.3 39.2 0.6 1.25 1.5 18.7 665 CPC-T1208-JM05B
12 7 x 0.3 39.2 0.6 1.25 1.6 20.7 800 CPC-T1212-JM05B
16 7 x 0.3 39.2 0.6 1.25 1.6 22.4 920 CPC-T1216-JM05B
20 7 x 0.3 39.2 0.6 1.6 1.7 25.3 1220 CPC-T1220-JM05B
24 7 x 0.3 39.2 0.6 1.6 1.7 27.2 1370 CPC-T1224-JM05B
30 7 x 0.3 39.2 0.6 1.6 1.9 30.1 1710 CPC-T1230-JM05B
0.75
2 7 x 0.37 24.6 0.6 0.8 1.5 15.6 395 CPC-T1202-JM08B
4 7 x 0.37 24.6 0.6 0.8 1.5 16.7 440 CPC-T1204-JM08B
8 7 x 0.37 24.6 0.6 1.25 1.6 21.5 760 CPC-T1208-JM08B
12 7 x 0.37 24.6 0.6 1.25 1.7 24.9 905 CPC-T1212-JM08B
16 7 x 0.37 24.6 0.6 1.6 1.7 27.0 1240 CPC-T1216-JM08B
20 7 x 0.37 24.6 0.6 1.6 1.8 29.6 1390 CPC-T1220-JM08B
24 7 x 0.37 24.6 0.6 1.6 1.9 32.7 1580 CPC-T1224-JM08B
30 7 x 0.37 24.6 0.6 1.6 2.0 36.1 1800 CPC-T1230-JM08B
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
Multipairs, Layers, Collective Screen, Galvanized Steel Wire Armour
TECHNICAL INFORMATION
PVC Insulation
UICElsewed
yIns
trumen
tation
Ca
bles
300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
22/126
A 14
Conductorsize
Numberof
pairs
Conductor
Nominalinsulationthickness
steel wirediameter
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weightUIC codeNo.x
dia.
Max.DC
Res. At20oC
mm2 No.No. xmm
Ohm/Km
mm mm mm mm Kg/Km -
1.0
2 7 x 0.43 18.4 0.6 0.8 1.5 15.2 440 CPC-T1202-JM12B
4 7 x 0.43 18.4 0.6 0.8 1.5 16.4 490 CPC-T1204-JM12B
8 7 x 0.43 18.4 0.6 1.25 1.6 21.1 840 CPC-T1208-JM12B
12 7 x 0.43 18.4 0.6 1.6 1.7 24.4 1200 CPC-T1212-JM12B
16 7 x 0.43 18.4 0.6 1.6 1.7 26.4 1380 CPC-T1216-JM12B
20 7 x 0.43 18.4 0.6 1.6 1.8 28.8 1580 CPC-T1220-JM12B
24 7 x 0.43 18.4 0.6 1.6 1.9 31.8 1850 CPC-T1224-JM12B
30 7 x 0.43 18.4 0.6 2.0 2.0 35.0 2470 CPC-T1230-JM12B
1.3
2 7 x 0.49 14.2 0.6 0.8 1.5 15.6 460 CPC-T1202-JM14B
4 7 x 0.49 14.2 0.6 1.25 1.5 18.1 630 CPC-T1204-JM14B
8 7 x 0.49 14.2 0.6 1.25 1.6 22.2 900 CPC-T1208-JM14B
12 7 x 0.49 14.2 0.6 1.6 1.7 25.3 1290 CPC-T1212-JM14B
16 7 x 0.49 14.2 0.6 1.6 1.8 28.1 1510 CPC-T1216-JM14B
20 7 x 0.49 14.2 0.6 1.6 1.8 30.4 1660 CPC-T1220-JM14B
24 7 x 0.49 14.2 0.6 1.6 1.9 32.5 1970 CPC-T1224-JM14B
30 7 x 0.49 14.2 0.6 2.0 2.0 35.9 2420 CPC-T1230-JM14B
1.5
2 7 x 0.53 12.6 0.6 1.25 1.6 18.2 620 CPC-T1202-JM15B
4 7 x 0.53 12.6 0.6 1.25 1.6 19.7 745 CPC-T1204-JM15B
8 7 x 0.53 12.6 0.6 1.6 1.7 25.2 1230 CPC-T1208-JM15B
12 7 x 0.53 12.6 0.6 1.6 1.8 28.1 1520 CPC-T1212-JM15B
16 7 x 0.53 12.6 0.6 1.6 1.9 31.3 1865 CPC-T1216-JM15B
20 7 x 0.53 12.6 0.6 1.6 1.9 34.1 2140 CPC-T1220-JM15B
24 7 x 0.53 12.6 0.6 2.0 2.0 38.3 2740 CPC-T1224-JM15B
30 7 x 0.53 12.6 0.6 2.0 2.0 41.6 3340 CPC-T1230-JM15B
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
TECHNICAL INFORMATION
PVC InsulationMultipairs, Layers, Collective Screen, Galvanized Steel Wire Armour
8/8/2019 Special Cables Catalogue - El Sewedy Cables
23/126
A 15
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogueand digital signals for measurements and process control purposes, where mechanical damagesare expected to occur.
Engneerng Specfcaton:
Standard:BS 5308-2
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polvinlchloride TI1 to BS 6746
Assembly:Cores twisted to form a pairs, pairs screenedb aluminium polester tapes, screened pairstwisted in concentric layers and wrapped by
polyester tapes
Colour code:Black / White continuousl numbered, oridenticationtapesnumbered
Screen:Collective screen of aluminum polester tapes withtinned drain wire and wrapped by polyester tapes
Beddng:Polvinlchloride
Armourng;Galvanized steel wire armour to BS 1442
Sheath:Polvinlchloride TM1 to BS 6746 colour black or blue
Mnmum bendng radus:10 x d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operation
Packng:On non-returnable wooden drums
Conductor
size
Number
of
pairs
ConductorNominal
insulation
thickness
steel wire
diameter
Nominal
sheath
thickness
Approximate
overall
diameter
Approximate
net
weight
UIC codeNo.x
dia.
Max. DC
Res. At20oC
mm2 No.No. x
mm
Ohm
/Kmmm mm mm mm Kg/Km -
0.5
2 7 x 0.3 39.2 0.6 0.8 1.4 14.7 390 CPC-T1202-SM05B
4 7 x 0.3 39.2 0.6 0.8 1.5 15.9 450 CPC-T1204-SM05B
8 7 x 0.3 39.2 0.6 1.25 1.6 20.4 760 CPC-T1208-SM05B
12 7 x 0.3 39.2 0.6 1.25 1.6 22.7 940 CPC-T1212-SM05B
16 7 x 0.3 39.2 0.6 1.6 1.7 25.5 1260 CPC-T1216-SM05B
20 7 x 0.3 39.2 0.6 1.6 1.8 27.8 1420 CPC-T1220-SM05B
24 7 x 0.3 39.2 0.6 1.6 1.9 30.7 1660 CPC-T1224-SM05B
30 7 x 0.3 39.2 0.6 1.6 1.9 33.0 2015 CPC-T1230-SM08B
0.75
2 7 x 0.37 24.6 0.6 0.8 1.5 15.6 440 CPC-T1202-SM08B
4 7 x 0.37 24.6 0.6 0.8 1.5 16.7 490 CPC-T1204-SM08B
8 7 x 0.37 24.6 0.6 1.25 1.6 21.5 850 CPC-T1208-SM08B
12 7 x 0.37 24.6 0.6 1.6 1.7 24.9 1210 CPC-T1212-SM08B
16 7 x 0.37 24.6 0.6 1.6 1.7 27.0 1390 CPC-T1216-SM08B
20 7 x 0.37 24.6 0.6 1.6 1.8 29.6 1620 CPC-T1220-SM08B
24 7 x 0.37 24.6 0.6 1.6 1.9 32.7 1880 CPC-T1224-SM08B30 7 x 0.37 24.6 0.6 2.0 2.0 36.1 2590 CPC-T1230-SM08B
Individual and Collective Screen, Galvanized Steel Wire Armour
TECHNICAL INFORMATION
PVC Insulation
UICElsewedyInstrumentationCables300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
24/126
A 16
Conductor
size
Number
of
pairs
ConductorNominal
insulation
thickness
steel wire
diameter
Nominal
sheath
thickness
Approximate
overall
diameter
Approximate
net
weight
UIC codeNo.x dia.
Max. DC
Res. At
20oC
mm2 No. No. x mmOhm/Km
mm mm mm mm Kg/Km -
1.0
2 7 x 0.43 18.4 0.6 1.25 1.5 17.2 570 CPC-T1202-SM12B
4 7 x 0.43 18.4 0.6 1.25 1.5 18.6 660 CPC-T1204-SM12B
8 7 x 0.43 18.4 0.6 1.25 1.7 23.1 960 CPC-T1208-SM12B
12 7 x 0.43 18.4 0.6 1.6 1.7 26.3 1335 CPC-T1212-SM12B
16 7 x 0.43 18.4 0.6 1.6 1.8 28.7 1570 CPC-T1216-SM12B
20 7 x 0.43 18.4 0.6 1.6 1.9 32.0 1870 CPC-T1220-SM12B
24 7 x 0.43 18.4 0.6 1.6 1.9 34.6 2120 CPC-T1224-SM12B
30 7 x 0.43 18.4 0.6 2.0 2.1 38.3 2830 CPC-T1230-SM12B
1.3
2 7 x 0.49 14.2 0.6 1.25 1.5 18.2 680 CPC-T1202-SM14B
4 7 x 0.49 14.2 0.6 1.25 1.6 20.3 850 CPC-T1204-SM14B
8 7 x 0.49 14.2 0.6 1.6 1.7 26.4 1350 CPC-T1208-SM14B
12 7 x 0.49 14.2 0.6 1.6 1.8 29.5 1560 CPC-T1212-SM14B
16 7 x 0.49 14.2 0.6 1.6 1.9 32.0 1860 CPC-T1216-SM14B
20 7 x 0.49 14.2 0.6 2.0 2.0 36.6 2300 CPC-T1220-SM14B
24 7 x 0.49 14.2 0.6 2.0 2.1 39.3 3200 CPC-T1224-SM14B
30 7 x 0.49 14.2 0.6 2.0 2.2 44.2 3900 CPC-T1230-SM14B
1.5
2 7 x 0.53 12.6 0.6 1.25 1.7 22.8 1000 CPC-T1202-SM15B
4 7 x 0.53 12.6 0.6 1.25 1.7 24.1 1130 CPC-T1204-SM15B
8 7 x 0.53 12.6 0.6 1.6 1.8 30.4 1690 CPC-T1208-SM15B
12 7 x 0.53 12.6 0.6 1.6 1.9 34.1 2130 CPC-T1212-SM15B
16 7 x 0.53 12.6 0.6 1.6 2.0 38.7 2280 CPC-T1216-SM15B
20 7 x 0.53 12.6 0.6 2.0 2.2 43.3 3430 CPC-T1220-SM15B
24 7 x 0.53 12.6 0.6 2.0 2.3 48.5 4420 CPC-T1224-SM15B
30 7 x 0.53 12.6 0.6 2.5 2.5 52.8 5390 CPC-T1230-SM15B
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
Multipairs, Layers, Individual and Collective Screen, Galvanized Steel Wire Armour
TECHNICAL INFORMATION
PVC Insulation
8/8/2019 Special Cables Catalogue - El Sewedy Cables
25/126
8/8/2019 Special Cables Catalogue - El Sewedy Cables
26/126
A 18
Cable SizeConductor Nominal
insulationthickness
Nominalsheath
thickness
Approximateoveralldiameter
Approximatenetweight
UIC codeNo.x dia.
Max. DC Res. At20oC
mm2 No. x mm Ohm /Km mm mm mm Kg/Km -
1 x 2 x 0.5 7 x 0.3 39.2 0.6 0.8 5.3 40 CGC-T1201-JU05B
1 x 3 x 0.5 7 x 0.3 39.2 0.6 0.8 5.6 50 CGC-T1301- JU05B
1 x 2 x 0.75 7 x 0.37 24.6 0.6 0.8 6.4 56 CGC-T1201- JU08B
1 x 3 x 0.75 7 x 0.37 24.6 0.6 0.8 6.7 65 CGC-T1301- JU08B
1 x 2 x 1.0 7 x 0.43 18.4 0.6 0.8 6.8 66 CGC-T1201- JU12B
1 x 3 x 1.0 7 x 0.43 18.4 0.6 0.8 7.1 75 CGC-T1301- JU12B
1 x 2 x 1.3 7 x 0.49 14.2 0.6 0.8 7.1 75 CGC-T1201- JU14B
1 x 3 x 1.3 7 x 0.49 14.2 0.6 0.8 7.4 85 CGC-T1301- JU14B1 x 2 x 1.5 7 x 0.53 12.6 0.6 0.8 7.6 85 CGC-T1201- JU15B
1 x 3 x 1.5 7 x 0.53 12.6 0.6 0.8 8.0 104 CGC-T1301- JU15B
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
TECHNICAL INFORMATION
Single Pair or Triple, Collective Screen
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogue anddigital signals for measurements and process control purposes.
Engneerng Specfcaton:
Standard:BS 5308-2
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polethelene tpe 03 to BS 6234
Assembly:Cores twisted to form a pair or triple and
wrapped by polyester tape
Colour code:Pair: Black / WhiteTriple: Black / White / Red
Wrappng:Polester tapes
Collectve Screen:Collective screen of aluminum polester tapes withtinned drain wire and wrapped by polyester tapes
Sheath:Polvinlchloride TM1 to BS 6746 colour
black or blue
Mnmum bendng radus:7.5 x d (d= overall diameter)
Temperature ratng:+5oC up to +50oC during operation
Packng:On non-returnable wooden drums
PE Insulation
UICElsewedyInstrumentationCables300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
27/126
A 19
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogueand digital signals for measurements and process control purposes.
Engneerng Specfcaton:
Standard:BS 5308-1
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polethelene TI1 to BS 6746
Assembly:Cores twisted to form a pairs,pairstwisted in concentric layers and
wrapped by polyester tapes
Colour code:Black / White continuousl numbered, oridentication tapes numbered
Screen:Collective screen of aluminum polester tapes withtinned drain wire and wrapped by polyester tapes
Sheath:Polvinlchloride TM1 to BS 6746 colour black or blue
Mnmum bendng radus:7.5 x d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operation
Packng:On non-returnable wooden drums
Conductorsize
Numberof
pairs
ConductorNominalinsulationthickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weightUIC code
No.x dia.Max. DC Res.
At 20oC
mm2 No.No. xmm
Ohm /Km mm mm mm Kg/Km -
0.5
2 7 x 0.3 39.2 0.6 1.0 9.3 98 CGC-T1202-JU05B
4 7 x 0.3 39.2 0.6 1.0 10.0 112 CGC-T1204-JU05B
8 7 x 0.3 39.2 0.6 1.2 13.2 189 CGC-T1208-JU05B
12 7 x 0.3 39.2 0.6 1.2 15.0 252 CGC-T1212-JU05B
16 7 x 0.3 39.2 0.6 1.2 16.7 318 CGC-T1216-JU05B
20 7 x 0.3 39.2 0.6 1.3 18.7 387 CGC-T1220-JU05B
24 7 x 0.3 39.2 0.6 1.3 20.6 452 CGC-T1224-JU05B
30 7 x 0.3 39.2 0.6 1.5 23.3 640 CGC-T1230-JU08B
0.75
2 7 x 0.37 24.6 0.6 1.0 10.1 120 CGC-T1202-JU08B
4 7 x 0.37 24.6 0.6 1.0 10.8 134 CGC-T1204-JU08B
8 7 x 0.37 24.6 0.6 1.2 14.3 232 CGC-T1208-JU08B
12 7 x 0.37 24.6 0.6 1.2 16.3 315 CGC-T1212-JU08B
16 7 x 0.37 24.6 0.6 1.3 18.3 410 CGC-T1216-JU08B
20 7 x 0.37 24.6 0.6 1.3 20.3 490 CGC-T1220-JU08B
24 7 x 0.37 24.6 0.6 1.3 22.5 575 CGC-T1224-JU08B
30 7 x 0.37 24.6 0.6 1.5 24.3 683 CGC-T1230-JU08B
Multipairs, Layers, Collective Screen
TECHNICAL INFORMATION
PE Insulation
UIC
ElsewedyInstrumentationCables300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
28/126
A 20
Conductor
size
Numberof
pairs
Conductor Nominalinsulation
thickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weight
UIC codeNo.x dia.
Max. DCRes. At20oC
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km -
1.0
2 7 x 0.43 18.4 0.6 1.0 10.8 138 CGC-T1202-JU12B
4 7 x 0.43 18.4 0.6 1.0 11.6 160 CGC-T1204-JU12B
8 7 x 0.43 18.4 0.6 1.2 15.4 282 CGC-T1208- JU12B
12 7 x 0.43 18.4 0.6 1.3 17.8 396 CGC-T1212-JU12B
16 7 x 0.43 18.4 0.6 1.3 19.8 504 CGC-T1216- JU12B
20 7 x 0.43 18.4 0.6 1.3 22.0 608 CGC-T1220-JU12B
24 7 x 0.43 18.4 0.6 1.5 24.8 745 CGC-T1224-JU12B
30 7 x 0.43 18.4 0.6 1.7 27.5 1005 CGC-T1230-JU12B
1.3
2 7 x 0.49 14.2 0.6 1.0 11.7 152 CGC-T1202-JU14B
4 7 x 0.49 14.2 0.6 1.2 13.3 215 CGC-T1204-JU14B
8 7 x 0.49 14.2 0.6 1.3 16.5 360 CGC-T1208- JU14B
12 7 x 0.49 14.2 0.6 1.3 19.3 385 CGC-T1212-JU14B
16 7 x 0.49 14.2 0.6 1.3 21.7 575 CGC-T1216-JU14B
20 7 x 0.49 14.2 0.6 1.5 24.2 780 CGC-T1220-JU14B
24 7 x 0.49 14.2 0.6 1.7 26.3 930 CGC-T1224-JU14B
30 7 x 0.49 14.2 0.6 1.7 31.0 1280 CGC-T1230-JU14B
1.5
2 7 x 0.53 12.6 0.6 1.2 12.9 194 CGC-T1202-JU15B
4 7 x 0.53 12.6 0.6 1.2 14.1 233 CGC-T1204-JU15B
8 7 x 0.53 12.6 0.6 1.3 18.6 405 CGC-T1208-JU15B
12 7 x 0.53 12.6 0.6 1.3 21.3 564 CGC-T1212-JU15B
16 7 x 0.53 12.6 0.6 1.5 24.3 797 CGC-T1216-JU15B
20 7 x 0.53 12.6 0.6 1.5 27.1 912 CGC-T1220-JU15B
24 7 x 0.53 12.6 0.6 1.7 30.3 1104 CGC-T1224-JU15B
30 7 x 0.53 12.6 0.6 2.0 33.7 1507 CGC-T1230-JU15B
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
TECHNICAL INFORMATION
PE InsulationMultipairs, Layers, Collective Screen
8/8/2019 Special Cables Catalogue - El Sewedy Cables
29/126
A 21
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogue anddigital signals for measurements and process control purposes.
Engineering Specication:
Standard:BS 5308-1
Rated Voltage:300/500 V
Conductor:Stranded plain annealed copper
insulaton:Polethelene 03 to BS 6234
Assembly:Cores twisted to form a pairs, pairs screenedb Aluminium Polester tapes, Screened pairstwisted in concentric layers and wrapped by
polyester tapes
Colour code:Black / White continuousl numbered, oridentication tapes numbered
Screen:Collective screen of Aluminum Polester tapeswith tinned drain wire and wrapped by polyester
tapes
Sheath:Polvinlchloride TM1 to BS 6746 colour black or blue
Mnmum bendng radus:
7.5 x d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operation
Packng:On non-returnable wooden drums
Conductorsize
Numberof
pairs
Conductor Nominalinsulationthickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weightUIC code
No.x dia.Max. DC Res. At
20oC
mm2 No.No. xmm
Ohm /Km mm mm mm Kg/Km -
0.5
2 7 x 0.3 39.2 0.6 1.0 10.3 118 CGC-T1202-SU05B
4 7 x 0.3 39.2 0.6 1.0 11.1 136 CGC-T1204-SU05B
8 7 x 0.3 39.2 0.6 1.2 14.7 234 CGC-T1208-SU05B
12 7 x 0.3 39.2 0.6 1.3 17.0 325 CGC-T1212-SU05B
16 7 x 0.3 39.2 0.6 1.3 18.9 413 CGC-T1216-SU05B
20 7 x 0.3 39.2 0.6 1.3 21.0 495 CGC-T1220-SU05B24 7 x 0.3 39.2 0.6 1.5 23.7 606 CGC-T1224-SU05B
30 7 x 0.3 39.2 0.6 1.5 26.3 822 CGC-T1230-SU08B
0.75
2 7 x 0.37 24.6 0.6 1.0 11.2 145 CGC-T1202-SU08B
4 7 x 0.37 24.6 0.6 1.0 11.9 159 CGC-T1204-SU08B
8 7 x 0.37 24.6 0.6 1.2 15.8 280 CGC-T1208-SU08B
12 7 x 0.37 24.6 0.6 1.3 18.3 390 CGC-T1212-SU08B
16 7 x 0.37 24.6 0.6 1.3 20.4 500 CGC-T1216-SU08B
20 7 x 0.37 24.6 0.6 1.3 22.8 602 CGC-T1220-SU08B
24 7 x 0.37 24.6 0.6 1.5 25.7 736 CGC-T1224-SU08B
30 7 x 0.37 24.6 0.6 1.7 26.4 864 CGC-T1230-SU08B
Multipairs, Layers, Individual and Collective Screen
TECHNICAL INFORMATION
PE Insulation
UICE
lsewedyInstrumentationCables300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
30/126
A 22
Conductorsize
Numberof
pairs
ConductorNominalinsulationthickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weightUIC code
No.x dia.Max. DCRes. At20oC
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km -
1.0
2 7 x 0.43 18.4 0.6 1.2 12.2 170 CGC-T1202-SU12B
4 7 x 0.43 18.4 0.6 1.2 13.1 195 CGC-T1204- SU12B
8 7 x 0.43 18.4 0.6 1.3 17.2 340 CGC-T1208- SU12B
12 7 x 0.43 18.4 0.6 1.3 19.7 465 CGC-T1212- SU12B
16 7 x 0.43 18.4 0.6 1.3 21.9 600 CGC-T1216- SU12B
20 7 x 0.43 18.4 0.6 1.5 25.0 645 CGC-T1220- SU12B
24 7 x 0.43 18.4 0.6 1.5 27.6 880 CGC-T1224- SU12B
30 7 x 0.43 18.4 0.6 1.7 30.5 1195 CGC-T1230- SU12B
1.3
2 7 x 0.49 14.2 0.6 1.2 12.8 180 CGC-T1202- SU14B
4 7 x 0.49 14.2 0.6 1.3 14.0 230 CGC-T1204- SU14B
8 7 x 0.49 14.2 0.6 1.3 18.2 410 CGC-T1208- SU14B
12 7 x 0.49 14.2 0.6 1.3 20.3 590 CGC-T1212- SU14B
16 7 x 0.49 14.2 0.6 1.5 23.3 760 CGC-T1216- SU14B
20 7 x 0.49 14.2 0.6 1.5 27.0 850 CGC-T1220- SU14B
24 7 x 0.49 14.2 0.6 1.7 31.2 1065 CGC-T1224- SU14B
30 7 x 0.49 14.2 0.6 2.0 34.5 1400 CGC-T1230- SU14B
1.5
2 7 x 0.53 12.6 0.6 1.2 14.1 220 CGC-T1202- SU15B
4 7 x 0.53 12.6 0.6 1.2 15.4 263 CGC-T1204- SU15B
8 7 x 0.53 12.6 0.6 1.3 20.3 460 CGC-T1208- SU15B
12 7 x 0.53 12.6 0.6 1.5 24.0 670 CGC-T1212- SU15B
16 7 x 0.53 12.6 0.6 1.5 26.7 865 CGC-T1216- SU15B20 7 x 0.53 12.6 0.6 1.7 30.2 1070 CGC-T1220- SU15B
24 7 x 0.53 12.6 0.6 2.0 34.0 1300 CGC-T1224- SU15B
30 7 x 0.53 12.6 0.6 2.2 37.4 1750 CGC-T1230- SU15B
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
Multipairs, Layers, Individual and Collective Screen
TECHNICAL INFORMATION
PE Insulation
8/8/2019 Special Cables Catalogue - El Sewedy Cables
31/126
A 23
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission ofanalogue and digital signals for measurements and process control purposes.
Engineering Specication:
Standard:BS 5308-1
Rated Voltage:300/500 V
Conductor:Stranded plain annealed copper
insulaton:Polethelene 03 to BS 6234
Assembly:Cores twisted to form a triples, triples twisted inconcentric layers and
wrapped by polyester tapes
Colour code:Black / White/ Red continuousl numbered, oridentication tapes numbered
Screen:Collective screen of aluminum polestertapes with tinned drain wire and wrapped
by polyester tapes
Sheath:Polvinlchloride TM1 to BS 6746 colourblack or blue
Mnmum bendng radus:7.5 x d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operation
Packng:On non-returnable wooden drums
Conductor
size
Numberof
Triples
Conductor Nominalinsulationthickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weightUIC codeNo.x
dia.
Max. DC Res.
At 20oC
mm2 No.No. x
mmOhm/Km mm mm mm Kg/Km -
0.5
2 7 x 0.3 39.2 0.6 1.0 10.1 115 CGC-T1302-JU05B
4 7 x 0.3 39.2 0.6 1.0 10.8 135 CGC-T1304-JU05B
8 7 x 0.3 39.2 0.6 1.2 14.6 230 CGC-T1308-JU05B
12 7 x 0.3 39.2 0.6 1.3 16.5 330 CGC-T1312-JU05B
16 7 x 0.3 39.2 0.6 1.3 18.7 420 CGC-T1316-JU05B
20 7 x 0.3 39.2 0.6 1.3 21.2 535 CGC-T1320-JU05B
24 7 x 0.3 39.2 0.6 1.5 24.0 635 CGC-T1324-JU05B
30 7 x 0.3 39.2 0.6 1.5 27.7 960 CGC-T1330-JU08B
0.75
2 7 x 0.37 24.6 0.6 1.0 10.9 130 CGC-T1302-JU08B
4 7 x 0.37 24.6 0.6 1.0 11.8 175 CGC-T1304-JU08B
8 7 x 0.37 24.6 0.6 1.3 15.9 355 CGC-T1308-JU08B
12 7 x 0.37 24.6 0.6 1.3 17.9 415 CGC-T1312-JU08B
16 7 x 0.37 24.6 0.6 1.3 20.2 515 CGC-T1316-JU08B
20 7 x 0.37 24.6 0.6 1.5 23.8 645 CGC-T1320-JU08B
24 7 x 0.37 24.6 0.6 1.5 26.0 955 CGC-T1324-JU08B
30 7 x 0.37 24.6 0.6 1.7 30.0 1150 CGC-T1330-JU08B
Multitriples, Layers, Collective Screen
TECHNICAL INFORMATION
PE Insulation
UiCElsewedyinstrume
ntatonCables300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
32/126
A 24
Conductorsize
Numberof
Triples
ConductorNominalinsulationthickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weightUIC code
No.x dia.Max. DCRes. At20oC
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km -
1.0
2 7 x 0.43 18.4 0.6 1.2 12.1 160 CGC-T1302-JU12B
4 7 x 0.43 18.4 0.6 1.2 13.6 240 CGC-T1304- JU12B
8 7 x 0.43 18.4 0.6 1.3 17.6 420 CGC-T1308- JU12B
12 7 x 0.43 18.4 0.6 1.3 20.3 570 CGC-T1312- JU12B
16 7 x 0.43 18.4 0.6 1.3 22.8 730 CGC-T1316- JU12B
20 7 x 0.43 18.4 0.6 1.5 25.6 900 CGC-T1320- JU12B
24 7 x 0.43 18.4 0.6 1.5 27.6 1050 CGC-T1324- JU12B30 7 x 0.43 18.4 0.6 1.7 33.2 1295 CGC-T1330- JU12B
1.3
2 7 x 0.49 14.2 0.6 1.2 12.8 190 CGC-T1302- JU14B
4 7 x 0.49 14.2 0.6 1.3 14.4 275 CGC-T1304- JU14B
8 7 x 0.49 14.2 0.6 1.3 18.8 485 CGC-T1308- JU14B
12 7 x 0.49 14.2 0.6 1.3 21.7 685 CGC-T1312- JU14B
16 7 x 0.49 14.2 0.6 1.5 25.0 910 CGC-T1316- JU14B
20 7 x 0.49 14.2 0.6 1.5 27.4 1100 CGC-T1320- JU14B
24 7 x 0.49 14.2 0.6 1.7 29.6 1300 CGC-T1324- JU14B
30 7 x 0.49 14.2 0.6 2.0 35.6 1590 CGC-T1330- JU14B
1.5
2 7 x 0.53 12.6 0.6 1.2 14.0 220 CGC-T1302- JU15B
4 7 x 0.53 12.6 0.6 1.3 15.9 300 CGC-T1304- JU15B
8 7 x 0.53 12.6 0.6 1.3 20.8 545 CGC-T1308- JU15B
12 7 x 0.53 12.6 0.6 1.5 24.8 785 CGC-T1312- JU15B
16 7 x 0.53 12.6 0.6 1.5 27.9 1100 CGC-T1316- JU15B
20 7 x 0.53 12.6 0.6 1.7 30.7 1250 CGC-T1320- JU15B
24 7 x 0.53 12.6 0.6 2.0 33.1 1460 CGC-T1324- JU15B
30 7 x 0.53 12.6 0.6 2.2 37.3 1920 CGC-T1330- JU15B
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
TECHNICAL INFORMATION
PE InsulationMultitriples, Layers, Collective Screen
8/8/2019 Special Cables Catalogue - El Sewedy Cables
33/126
A 25
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogue anddigital signals for measurements and process control purposes.
Engneerng Specfcaton:
Standard:BS 5308-1
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polethelene 03 to BS 6234
Assembly:Cores twisted to form triples, triples screenedb aluminium b polester tapes, screenedtriples Twisted in concentric laers andwrapped by polyester tapes
Colour code:Black / White/ Red, continuousl numbered,or identification tapes numbered
Screen:Collective screen of aluminum polester tapes withtinned drain wire and wrapped by polyester tapes
Sheath:Polvinlchloride TM1 to BS 6746 colour black or blue
Mnmum bendng radus:7.5 x d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operation
Packng:On non-returnable wooden drums
Conductorsize
Number
of
triples
Conductor Nominal
insulation
thickness
Nominal
sheath
thickness
Approximate
overall
diameter
Approximate
net
weight
UIC codeNo.x dia.
Max. DC Res. At20oC
mm2 No.No. xmm
Ohm /Km mm mm mm Kg/Km -
0.5
2 7 x 0.3 39.2 0.6 1.0 11.7 145 CGC-T1302-SU05B
4 7 x 0.3 39.2 0.6 1.2 13.2 195 CGC-T1304-SU05B
8 7 x 0.3 39.2 0.6 1.3 17.0 320 CGC-T1308-SU05B
12 7 x 0.3 39.2 0.6 1.3 19.6 430 CGC-T1312-SU05B
16 7 x 0.3 39.2 0.6 1.3 22.0 560 CGC-T1316-SU05B
20 7 x 0.3 39.2 0.6 1.5 24.7 680 CGC-T1320-SU05B
24 7 x 0.3 39.2 0.6 1.5 26.6 800 CGC-T1324-SU05B30 7 x 0.3 39.2 0.6 1.7 29.2 1100 CGC-T1330-SU08B
0.75
2 7 x 0.37 24.6 0.6 1.0 12.5 160 CGC-T1302-SU08B
4 7 x 0.37 24.6 0.6 1.2 14.1 220 CGC-T1304-SU08B
8 7 x 0.37 24.6 0.6 1.3 18.3 380 CGC-T1308-SU08B
12 7 x 0.37 24.6 0.6 1.3 21.1 530 CGC-T1312-SU08B
16 7 x 0.37 24.6 0.6 1.5 24.2 690 CGC-T1316-SU08B
20 7 x 0.37 24.6 0.6 1.7 26.7 845 CGC-T1320-SU08B
24 7 x 0.37 24.6 0.6 1.7 28.8 1000 CGC-T1324-SU08B
30 7 x 0.37 24.6 0.6 2.0 32.4 1300 CGC-T1330-SU08B
Multitriples, Layers, Individual and Collective Screen
TECHNICAL INFORMATION
PE Insulation
UiCElsewedyinstrumentatonCables300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
34/126
A 26
TECHNICAL INFORMATION
ConductorSize
Numberof Triples
ConductorNominalInsulationThickness
NominalSheath
Thickness
ApproximateOverall
Diameter
ApproximateNet Weight
Cable CodeNo. xdia
Max.DCRes.
At 20
mm2 .NoNo. xmm
Ohm/Km
mm mm mm Kg/Km -
1.0
2 7 X 0.43 18.4 0.6 1.2 13.7 185 CGC-T1302-SU12B
4 7 X 0.43 18.4 0.6 1.3 15.5 270 CGC-T1304-SU12B
8 7 X 0.43 18.4 0.6 1.3 20.3 465 CGC-T1308-SU12B
12 7 X 0.43 18.4 0.6 1.3 23.5 650 CGC-T1312-SU12B
16 7 X 0.43 18.4 0.6 1.5 27.1 850 CGC-T1316-SU12B
20 7 X 0.43 18.4 0.6 1.7 29.8 1030 CGC-T1320-SU12B
24 7 X 0.43 18.4 0.6 1.7 32.2 1220 CGC-T1324-SU12B
30 7 X 0.43 18.4 0.6 2.0 35.3 1480 CGC-T1330-SU12B
1.3
2 7 X 0.49 14.2 0.6 1.3 14.4 220 CGC-T1302-SU14B
4 7 X 0.49 14.2 0.6 1.3 16.4 310 CGC-T1304-SU14B
8 7 X 0.49 14.2 0.6 1.3 21.6 540 CGC-T1308-SU14B
12 7 X 0.49 14.2 0.6 1.5 25.6 780 CGC-T1312-SU14B
16 7 X 0.49 14.2 0.6 1.7 28.9 1010 CGC-T1316-SU14B
20 7 X 0.49 14.2 0.6 1.7 31.8 1190 CGC-T1320-SU14B
24 7 X 0.49 14.2 0.6 2.0 35.4 1475 CGC-T1324-SU14B
30 7 X 0.49 14.2 0.6 2.0 37.2 1680 CGC-T1330-SU14B
1.5
2 7 X 0.53 12.6 0.6 1.3 15.2 255 CGC-T1302-SU15B
4 7 X 0.53 12.6 0.6 1.3 17.3 340 CGC-T1304-SU15B
8 7 X 0.53 12.6 0.6 1.3 22.9 570 CGC-T1308-SU15B
12 7 X 0.53 12.6 0.6 1.5 27.2 900 CGC-T1312-SU15B
16 7 X 0.53 12.6 0.6 1.7 30.7 1150 CGC-T1316-SU15B
20 7 X 0.53 12.6 0.6 2.0 33.8 1400 CGC-T1320-SU15B
24 7 X 0.53 12.6 0.6 2.2 37.0 1660 CGC-T1324-SU15B
30 7 X 0.53 12.6 0.6 2.2 40.6 2100 CGC-T1330-SU15B
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
PE InsulationMultitriples, Layers, Individual and Collective Screen
8/8/2019 Special Cables Catalogue - El Sewedy Cables
35/126
A 27
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmissionof analogue and digital signals for measurements and process control purposes, wheremechanical damages are expected to occur.
Engneerng Specfcaton:
Standard:BS 5308-1
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polethelene 03 to BS 6234
Assembly:Cores twisted to form a pair or triple and
screened by aluminium polyester tape with
tinned drain wire and wrapped by polyester
tapes
Colour code:Black / White
Beddng:Polvinlchloride
Armourng:Galvanized steel wire armour to BS 1442
Sheath:Polvinlchloride TM1 to BS 6746 colour black or blue
Mnmum bendng radus:10 x d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operation
Packng:On non-returnable wooden drums
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
Single Pair, Collective Screen, Galvanized Steel Wire Armour
TECHNICAL INFORMATION
Conductor
Size
Number
of
Pairs
ConductorNominal
Insulation
Thickness
Steel wire
diameter
Nominal
Sheath
thickness
Approximate
Overall
diameter
Approximate
Net
Weight
UIC- CodeNo. x
dia
Max.DC
Res.At 20
mm2 No.No. x
mm
Ohm/
Kmmm mm mm mm Kg/Km -
0.5 1 7 x 0.3 39.2 0.6 0.8 1.3 10.3 210 CGC-T1201-JM05B
0.75 1 7 x 0.37 24.6 0.6 0.8 1.3 11.0 230 CGC-T1201-JM08B
1.0 1 7 x 0.43 18.4 0.6 0.8 1.3 11.4 240 CGC-T1201-JM12B
1.3 1 7 x 0.49 14.2 0.6 0.8 1.4 11.8 260 CGC-T1201-JM14B
1.5 1 7 x 0.53 12.6 0.6 0.8 1.4 12.6 290 CGC-T1201-JM15B
PE Insulation
UiCElsew
edyinstrumentatonCables300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
36/126
A 28
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogueand digital signals for measurements and process control purposes, where mechanical damagesare expected to occur.
Engneerng Specfcaton:
Standard:BS 5308-1
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polethelene 03 to BS 6234
Assembly:Cores twisted to form pairs, pairs twistedin concentric layers and wrapped by
polyester tapes
Colour code:Black / White, continuousl numbered,or identification tapes numbered
Screen:Collective screen of aluminum polester tapeswith tinned drain wire and wrapped by
polyester tapes
Beddng:Polvinlchloride
Armourng:Galvanized steel wire armour BS 1442
Sheath:Polvinlchloride TM1 to BS 6746 colour black or blue
Mnmum bendng radus:10x d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operation
Packng:On non-returnable wooden drums
Conductor
size
Number
of
pairs
Conductor Nominal
insulation
thickness
Steel
wire
diameter
Nominal
sheath
thickness
Approximate
overall
diameter
Approximate
net
weight
UIC codeNo.x dia.
Max. DC Res.
At 20oC
mm2 No.No. xmm
Ohm /Km mm mm mm mm Kg/Km -
0.5
2 7 x 0.3 39.2 0.6 0.8 1.4 13.5 330 CGC-T1202-JM05B
4 7 x 0.3 39.2 0.6 0.8 1.4 14.6 370 CGC-T1204-JM05B
8 7 x 0.3 39.2 0.6 1.25 1.5 18.7 630 CGC-T1208- JM05B
12 7 x 0.3 39.2 0.6 1.25 1.6 20.7 770 CGC-T1212- JM05B
16 7 x 0.3 39.2 0.6 1.25 1.6 22.4 880 CGC-T1216- JM05B
20 7 x 0.3 39.2 0.6 1.6 1.7 25.3 1170 CGC-T1220- JM05B24 7 x 0.3 39.2 0.6 1.6 1.7 27.2 1340 CGC-T1224- JM05B
30 7 x 0.3 39.2 0.6 1.6 1.9 30.1 1660 CGC-T1230- JM05B
0.75
2 7 x 0.37 24.6 0.6 0.8 1.5 15.6 370 CGC-T1202- JM08B
4 7 x 0.37 24.6 0.6 0.8 1.5 16.7 410 CGC-T1204- JM08B
8 7 x 0.37 24.6 0.6 1.25 1.6 21.5 720 CGC-T1208- JM08B
12 7 x 0.37 24.6 0.6 1.25 1.7 24.9 880 CGC-T1212- JM08B
16 7 x 0.37 24.6 0.6 1.6 1.7 27.0 1200 CGC-T1216- JM08B
20 7 x 0.37 24.6 0.6 1.6 1.8 29.6 1350 CGC-T1220- JM08B
24 7 x 0.37 24.6 0.6 1.6 1.9 32.7 1530 CGC-T1224- JM08B
30 7 x 0.37 24.6 0.6 1.6 2.0 36.1 1730 CGC-T1230- JM08B
Multipairs, Layers, Collective Screen, Galvanized Steel Wire Armour
TECHNICAL INFORMATION
PE Insulation
UiCElsewedyinstrumentatonCables300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
37/126
A 29
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specic request.
Multipairs, Layers, Collective Screen Galvanized Steel Wire Armour
TECHNICAL INFORMATION
ConductorSize
Number
of
Pairs
ConductorNominal
Insulation
Thickness
Steel wirediameter
Nominal
Sheath
thickness
ApproximateOveralldiameter
ApproximateNet
WeightUIC- CodeNo. x
dia
Max.DC
Res.At 20
mm2 No.No. xmm
Ohm/Km
mm mm mm mm Kg/Km -
1.0
2 7 X 0.43 18.4 0.6 0.8 1.5 15.2 420 CGC-T1202-JM12B
4 7 X 0.43 18.4 0.6 0.8 1.5 16.4 470 CGC-T1204-JM12B
8 7 X 0.43 18.4 0.6 1.25 1.6 21.1 820 CGC-T1208-JM12B
12 7 X 0.43 18.4 0.6 1.6 1.7 24.4 1170 CGC-T1212-JM12B
16 7 X 0.43 18.4 0.6 1.6 1.7 26.4 1350 CGC-T1216-JM12B20 7 X 0.43 18.4 0.6 1.6 1.8 28.8 1530 CGC-T1220-JM12B
24 7 X 0.43 18.4 0.6 1.6 1.9 31.8 1760 CGC-T1224-JM12B
30 7 X 0.43 18.4 0.6 2.0 2.0 35.0 2390 CGC-T1230-JM12B
1.3
2 7 X 0.49 14.2 0.6 0.8 1.5 15.6 430 CGC-T1202-JM14B
4 7 X 0.49 14.2 0.6 1.25 1.5 18.1 600 CGC-T1204-JM14B
8 7 X 0.49 14.2 0.6 1.25 1.6 22.2 860 CGC-T1208-JM14B
12 7 X 0.49 14.2 0.6 1.6 1.7 25.3 1240 CGC-T1212-JM14B
16 7 X 0.49 14.2 0.6 1.6 1.8 28.1 1460 CGC-T1216-JM14B
20 7 X 0.49 14.2 0.6 1.6 1.8 30.4 1600 CGC-T1220-JM14B
24 7 X 0.49 14.2 0.6 1.6 1.9 32.5 1900 CGC-T1224-JM14B
30 7 X 0.49 14.2 0.6 2.0 2.0 35.9 2850 CGC-T1230-JM14B
1.5
2 7 X 0.53 12.6 0.6 1.25 1.6 18.2 600 CGC-T1202-JM15B4 7 X 0.53 12.6 0.6 1.25 1.6 19.7 705 CGC-T1204-JM15B
8 7 X 0.53 12.6 0.6 1.6 1.7 25.2 1190 CGC-T1208-JM15B
12 7 X 0.53 12.6 0.6 1.6 1.8 28.1 1460 CGC-T1212-JM15B
16 7 X 0.53 12.6 0.6 1.6 1.9 31.3 1800 CGC-T1216-JM15B
20 7 X 0.53 12.6 0.6 1.6 1.9 34.1 2090 CGC-T1220-JM15B
24 7 X 0.53 12.6 0.6 2.0 2.0 38.3 2680 CGC-T1224-JM15B
30 7 X 0.53 12.6 0.6 2.0 2.2 41.6 3220 CGC-T1230-JM15B
PE Insulation
8/8/2019 Special Cables Catalogue - El Sewedy Cables
38/126
A 30
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogueand digital signals for measurements and process control purposes, where mechanical damagesare expected to occur.
Engneerng Specfcaton:
Standard:BS 5308-1
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polethelene 03 to BS 6234
Assembly:Cores twisted to form pairs, pairs screenedb aluminium polester tapes, screenedpairs twisted in concentric layer and
wrapped by polyester tapes
Colour code:Black / White, continuousl numbered, oridentication tapes numbered
Screen:Collective screen of aluminum polester tapes withtinned drain wire and wrapped b polester tapes.
Beddng:Polvinlchloride
Armourng:
Galvanized steel wire armour to BS 1442
Sheath:Polvinlchloride TM1 to BS 6746 colour black or blue
Mnmum bendng radus:10x d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operation
Conductorsize
Numberof
pairs
Conductor Nominalinsulationthickness
Steel wirediameter
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weightUIC code
No.x dia.Max. DC
Res. At 20oC
mm2 No.No. xmm
Ohm /Km mm mm mm mm Kg/Km -
0.5
2 7 x 0.3 39.2 0.6 0.8 1.4 14.7 315 CGC-T1202-JM05B
4 7 x 0.3 39.2 0.6 0.8 1.5 15.9 410 CGC-T1204-JM05B
8 7 x 0.3 39.2 0.6 1.25 1.6 20.4 690 CGC-T1208- JM05B
12 7 x 0.3 39.2 0.6 1.25 1.6 22.7 820 CGC-T1212- JM05B
16 7 x 0.3 39.2 0.6 1.6 1.7 25.5 1160 CGC-T1216- JM05B
20 7 x 0.3 39.2 0.6 1.6 1.8 27.8 1320 CGC-T1220- JM05B
24 7 x 0.3 39.2 0.6 1.6 1.9 30.7 1580 CGC-T1224- JM05B
30 7 x 0.3 39.2 0.6 1.6 1.9 33.0 1930 CGC-T1230- JM05B
0.75
2 7 x 0.37 24.6 0.6 0.8 1.5 15.6 355 CGC-T1202- JM08B
4 7 x 0.37 24.6 0.6 0.8 1.5 16.7 450 CGC-T1204- JM08B
8 7 x 0.37 24.6 0.6 1.25 1.6 21.5 755 CGC-T1208- JM08B
12 7 x 0.37 24.6 0.6 1.6 1.7 24.9 1110 CGC-T1212- JM08B
16 7 x 0.37 24.6 0.6 1.6 1.7 27.0 1260 CGC-T1216- JM08B
20 7 x 0.37 24.6 0.6 1.6 1.8 29.6 1540 CGC-T1220- JM08B
24 7 x 0.37 24.6 0.6 1.6 1.9 32.7 1760 CGC-T1224- JM08B
30 7 x 0.37 24.6 0.6 2.0 2.0 36.1 2470 CGC-T1230- JM08B
TECHNICAL INFORMATION
Multipairs, Layers, Individual and Collective Screen, Galvanized Steel Wire Armour
PE Insulation
UiCElsewedyins
trumentatonCables300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
39/126
A 31
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
ConductorSize
Numberof
Pairs
ConductorNominalInsulation
Thickness
Steel wirediameter
NominalSheath
thickness
ApproximateOverall
diameter
ApproximateNet
WeightUIC- Code
No. xdia
Max. DCRes. At
20
mm2 No.No. xmm
Ohm/Km mm mm mm mm Kg/Km -
1.0
2 7 X 0.43 18.4 0.6 1.25 1.5 17.2 500 CGC-T1202-SM12B
4 7 X 0.43 18.4 0.6 1.25 1.5 18.6 610 CGC-T1204-SM12B
8 7 X 0.43 18.4 0.6 1.25 1.7 23.1 920 CGC-T1208-SM12B
12 7 X 0.43 18.4 0.6 1.6 1.7 26.3 1290 CGC-T1212-SM12B
16 7 X 0.43 18.4 0.6 1.6 1.8 28.7 1500 CGC-T1216-SM12B
20 7 X 0.43 18.4 0.6 1.6 1.9 32.0 1810 CGC-T1220-SM12B
24 7 X 0.43 18.4 0.6 1.6 1.9 34.6 2130 CGC-T1224-SM12B
30 7 X 0.43 18.4 0.6 2.0 2.1 38.3 2760 CGC-T1230-SM12B
1.3
2 7 X 0.49 14.2 0.6 1.25 1.5 18.2 620 CGC-T1202-SM14B
4 7 X 0.49 14.2 0.6 1.25 1.6 20.3 800 CGC-T1204-SM14B
8 7 X 0.49 14.2 0.6 1.6 1.7 26.4 1290 CGC-T1208-SM14B
12 7 X 0.49 14.2 0.6 1.6 1.8 29.5 1480 CGC-T1212-SM14B
16 7 X 0.49 14.2 0.6 1.6 1.9 32.0 1800 CGC-T1216-SM14B
20 7 X 0.49 14.2 0.6 2.0 2.0 36.6 2220 CGC-T1220-SM14B
24 7 X 0.49 14.2 0.6 2.0 2.1 39.3 3130 CGC-T1224-SM14B
30 7 X 0.49 14.2 0.6 2.0 2.2 44.2 3810 CGC-T1230-SM14B
1.5
2 7 X 0.53 12.6 0.6 1.25 1.7 22.8 930 CGC-T1202-SM15B
4 7 X 0.53 12.6 0.6 1.25 1.7 24.1 1070 CGC-T1204-SM15B
8 7 X 0.53 12.6 0.6 1.6 1.8 30.4 1600 CGC-T1208-SM15B
12 7 X 0.53 12.6 0.6 1.6 1.9 34.1 2030 CGC-T1212-SM15B
16 7 X 0.53 12.6 0.6 1.6 2.0 38.7 2190 CGC-T1216-SM15B
20 7 X 0.53 12.6 0.6 2.0 2.2 43.3 3320 CGC-T1220-SM15B
24 7 X 0.53 12.6 0.6 2.0 2.3 48.5 4310 CGC-T1224-SM15B
30 7 X 0.53 12.6 0.6 2.5 2.5 52.8 5280 CGC-T1230-SM15B
TECHNICAL INFORMATION
PE InsulationMultipairs, Layers, Individual and Collective Screen, Galvanized Steel Wire Armour
8/8/2019 Special Cables Catalogue - El Sewedy Cables
40/126
A 32
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogueand digital signals for measurements and process control purposes.
Engneerng Specfcaton:
Standard:BS 5308-1
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polethelene 03 to BS 6234
Assembly:Cores twisted in concentric layers and
wrapped by polyester tapes
Colour code:Black continuousl numbered
Screen:Collective screen of tinned copper wire braid withcoverage from 60% up to 80% and wrapped bpolyester tapes
Sheath:Polvinlchloride TM1 to BS 6746 colour black or blue
Mnmum bendng radus:7.5x d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operation
Packng:On non-returnable wooden drums
Conductor
size
Numberof
Cores
Conductor Nominalinsulation
thickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weight
UIC codeNo. x dia.
Max. DCRes. At20oC
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km -
1.0
2 7 x 0.43 18.1 0.6 1.2 7.2 95 CGC-T1202-OU12B
3 7 x 0.43 18.1 0.6 1.2 7.6 110 CGC-T1103- OU12B
5 7 x 0.43 18.1 0.6 1.3 10.3 150 CGC-T1105- OU12B
7 7 x 0.43 18.1 0.6 1.3 11.1 180 CGC-T1107- OU12B
12 7 x 0.43 18.1 0.6 1.4 14.2 270 CGC-T1112- OU12B
19 7 x 0.43 18.1 0.6 1.4 16.3 380 CGC-T1119- OU12B
24 7 x 0.43 18.1 0.6 1.6 19.2 465 CGC-T1124- OU12B
1.5
2 7 x 0.53 12.1 0.6 1.2 9.0 125 CGC-T1102- OU15B
3 7 x 0.53 12.1 0.6 1.2 9.4 145 CGC-T1103- OU15B
5 7 x 0.53 12.1 0.6 1.3 11.2 200 CGC-T1105- OU15B
7 7 x 0.53 12.1 0.6 1.3 12.0 240 CGC-T1107- OU15B
12 7 x 0.53 12.1 0.6 1.4 15.4 375 CGC-T1112- OU15B
19 7 x 0.53 12.1 0.6 1.5 18.0 545 CGC-T1119- OU15B
24 7 x 0.53 12.1 0.6 1.6 21.0 670 CGC-T1124- OU15B
Multicores, Layers, Overall Screen of Tinned Copper Wire Braid
TECHNICAL INFORMATION
PE Insulation
UICElsewedyInstrumen
tationCables300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
41/126
A 33
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmission of analogueand digital signals for measurements and process control purposes.
Engneerng Specfcaton:
Standard:BS 5308-1
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polethelene 03 to BS 6234
Assembly:Cores twisted to form a pair wrapped by
polyester tapes
Colour code:Black / White
Screen:Collective screen of aluminium polester tapes andtinned copper wire braid with coverage from 60% upto 80% and wrapped b polester tapes
Sheath:Polvinlchloride TM1 to BS 6746 colour black or blue
Mnmum bendng radus:7.5 x d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operation
Packng:On non-returnable wooden drums
Single Pair, Collective Screen of Tinned Copper Wire Braid
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
TECHNICAL INFORMATION
ConductorSize
Conductor NominalInsulationThickness
NominalSheath
Thickness
ApproximateOverallDiameter
ApproximateNet Weight
Cable CodeNo. x dia
Max. DCRes. At
20
mm2 No. xmmOhm/
Km mm mm mm Kg/Km -
1 X 2 X 0.5 7 X 0.3 39.2 0.6 0.8 6.3 40 CGC-T120-OU05B
1 X 2 X 0.75 7 X 0.37 24.6 0.6 0.8 6.6 46 CGC-T120-OU08B
1 X 2 X 1.0 7 X 0.43 18.4 0.6 0.8 7.0 53 CGC-T120-OU12B
1 X 2 X 1.3 7 X 0.49 14.2 0.6 0.9 7.6 65 CGC-T120-OU14B
1 X 2 X 1.5 7 X 0.53 12.6 0.6 0.9 8.2 73 CGC-T120-OU15B
PE Insulation
UICElsewedyFireInstrumentationCables300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
42/126
A 34
Applcaton:
These cables are used in the chemical and petrochemical industries for the transmissionof analogue and digital signals for measurements and process control purposes.
Engneerng Specfcaton:
Standard:BS 5308-1
Rated Voltage:300/500 V
Conductor:Stranded annealed plain copper
insulaton:Polethelene 03 to BS 6234
Assembly:Cores twisted to form pairs, twisted pairs inconcentric layers and wrapped by polyester
tapes
Colour code:Black / White, continuousl numbered, oridentication tapes numbered
Screen:Collective screen of aluminum polester tapes andtinned copper wire braid with coverage from 60% upto 80% and wrapped b polester tapes
Sheath:Polvinlchloride TM1 to BS 6746 colour black or blue
Mnmum bendng radus:7.5 x d (d= overall diameter)
Temperature ratng:+5oC up to + 50oC during operation
Packng:On non-returnable wooden drums
Multipairs, Layers, Overall Screen of Tinned Copper Wire Braid
Conductor
size
Numberof
pairs
Conductor Nominalinsulation
thickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weightUIC code
No.x dia.Max. DC Res. At
20oC
mm2 No.No. xmm
Ohm /Km mm mm mm Kg/Km -
0.5
2 7 x 0.3 39.2 0.6 1.0 9.3 95 CGC-T1202-OU05B
4 7 x 0.3 39.2 0.6 1.0 10.0 115 CGC-T1204-OU05B
6 7 x 0.3 39.2 0.6 1.2 12.3 175 CGC-T1206- OU05B
8 7 x 0.3 39.2 0.6 1.2 13.2 190 CGC-T1208- OU05B
10 7 x 0.3 39.2 0.6 1.2 14.5 220 CGC-T1210- OU05B
12 7 x 0.3 39.2 0.6 1.2 15.0 250 CGC-T1212- OU05B
0.75
2 7 x 0.37 24.6 0.6 1.0 10.1 120 CGC-T1202- OU08B
4 7 x 0.37 24.6 0.6 1.0 10.8 134 CGC-T1204- OU08B
6 7 x 0.37 24.6 0.6 1.2 13.8 220 CGC-T1206- OU08B
8 7 x 0.37 24.6 0.6 1.2 14.3 230 CGC-T1208- OU08B
10 7 x 0.37 24.6 0.6 1.2 15.8 275 CGC-T1210- OU08B
12 7 x 0.37 24.6 0.6 1.2 16.3 320 CGC-T1212- OU08B
TECHNICAL INFORMATION
PE Insulation
UICElsewedyInstrumentationCables300V
8/8/2019 Special Cables Catalogue - El Sewedy Cables
43/126
A 35
Conductorsize
Numberof
pairs
ConductorNominalinsulationthickness
Nominalsheath
thickness
Approximateoverall
diameter
Approximatenet
weightUIC code
No.x dia.Max. DCRes. At20oC
mm2 No. No. x mm Ohm /Km mm mm mm Kg/km -
1.0
2 7 x 0.43 18.4 0.6 1.0 10.8 135 CGC-T1202-OU12B
4 7 x 0.43 18.4 0.6 1.0 11.6 160 CGC-T1204-OU12B
6 7 x 0.43 18.4 0.6 1.2 12.8 255 CGC-T1206-OU12B
8 7 x 0.43 18.4 0.6 1.2 15.4 280 CGC-T1208-OU12B
10 7 x 0.43 18.4 0.6 1.3 17.2 345 CGC-T1210-OU12B
12 7 x 0.43 18.4 0.6 1.3 17.8 400 CGC-T1212-OU12B
1.3
2 7 x 0.49 14.2 0.6 1.0 11.4 165 CGC-T1202-OU12B
4 7 x 0.49 14.2 0.6 1.2 13.5 195 CGC-T1204-OU12B
6 7 x 0.49 14.2 0.6 1.3 14.7 260 CGC-T1206-OU12B
8 7 x 0.49 14.2 0.6 1.3 16.6 340 CGC-T1208-OU12B
10 7 x 0.49 14.2 0.6 1.3 18.1 410 CGC-T1210- OU12B
12 7 x 0.49 14.2 0.6 1.3 20.2 480 CGC-T1212-OU12B
1.5
2 7 x 0.53 12.6 0.6 1.2 12.9 195 CGC-T1202- OU12B
4 7 x 0.53 12.6 0.6 1.2 14.1 230 CGC-T1204-OU12B
6 7 x 0.53 12.6 0.6 1.3 17.8 390 CGC-T1206-OU12B
8 7 x 0.53 12.6 0.6 1.3 18.6 405 CGC-T1208-OU12B
10 7 x 0.53 12.6 0.6 1.3 20.6 490 CGC-T1210-OU12B12 7 x 0.53 12.6 0.6 1.3 21.3 564 CGC-T1212-OU12B
The above data are approximate and subject to normal manufacturing tolerance.
Other tpes can be provided on specific request.
Multipairs, Layers, Overall Screen of Plain or Tinned Copper Wire Braid
TECHNICAL INFORMATION
PE Insulation
8/8/2019 Special Cables Catalogue - El Sewedy Cables
44/126
8/8/2019 Special Cables Catalogue - El Sewedy Cables
45/126
B 1
Fire Resistant Cables, Multicores, Layers, Collective Screen, Stranded Conductor....... 2
Fire Resistant Cables, Multipairs, Layers, Collective Screen, Stranded Conductor........ 3
Fire Resistant Cables, Multipairs, Layers, Individual and Collective Screen, Stranded Conductor..... 5
Fire Alarm Cables, Multicores, Unscreened, Stranded Conductor............................................................. 7
Fire Alarm Cables, Multipairs, Laers, Collective Screen, Stranded Conductor....................................... 8
Fire Alarm Cables, Multicores, Unscreened, Solid Conductor...................................................................... 9
Fire Alarm Cables, Multipairs, Laers, Collective Screen, Solid Conductor................................................. 10
Fire Alarm Cables, Multicores, Unscreened, Flexible Conductor................................................................. 11
Fire Alarm Cables, Multipairs, Laers, Collective Screen, Flexible Conductor........................................... 12
B. Fre Resstant & Fre
Alarm Cables
8/8/2019 Special Cables Catalogue - El Sewedy Cables
46/126
B 2
Applcaton:
These cables are used in re ghting alarm sstems in hazardous area where the safet is highl requiredduring re condition.
Engneerng Specfcaton:
Standard:
IEC 60502
Rated Voltage:
600 / 1000 V
Conductor:
Stranded plain / tinned annealed
copper
insulaton:
Flame barrier mica tape, cross-linkedpolyethylene
Assembly:
Cores twisted together in concentriclayers and wrapped by polyester tapes
Colour code:
Black continuousl numbered
Screen:
Collective screen of aluminum polester tapeswith tinned drain wire and wrapped by polyestertapes
Sheath:Halogen free, low smoke thermoplastic material,red colour
Mnmum bendng radus:
7.5 x d (d= overall diameter)
Fre resstant property:
750oC according to IEC 331
Conductor
size
Number
of
Cores
ConductorNominal
insulation
thickness
Nominal
sheath
thickness
Approximateoverall
diameter
Approximatenet
weight
UIC code
No.x dia.
Max. DC Res. At
20oC
mm2 No. No. x mm Ohm /Km mm mm mm Kg/Km -
1.5
2 7 x 0.52 12.1 0.7 1.8 10.5 115 CBA-TL102-JU15B
5 7 x 0.52 12.1 0.7 1.8 12.8 204 CBA-TL105-JU15B
7 7 x 0.52 12.1 0.7 1.8 13.8 212 CBA-TL107-JU15B
10 7 x 0.52 12.1 0.7 1.8 17.2 352 CBA-TL110-JU15B
12 7 x 0.52 12.1 0.7 1.8 17.8 402 CBA-TL112-JU15B
19 7 x 0.52 12.1 0.7 1.8 20.6 582 CBA-TL119-JU15B
24 7 x 0.52 12.1 0.7 1.8 23.9 720 CBA-TL124-JU15B
30 7 x 0.52 12.1 0.7 1.8 25.3 870 CBA-TL130-JU15B
37 7 x 0.52 12.1 0.7 1.8 27.3 1040 CBA-TL137-JU15B
2.5
2 7 x 0.67 7.41 0.7 1.8 11.4 146 CBA-TL102-JU18B
5 7 x 0.67 7.41 0.7 1.8 14.1 260 CBA-TL105-JU18B
7 7 x 0.67 7.41 0.7 1.8 15.2 325 CBA-TL107-JU18B
10 7 x 0.67 7.41 0.7 1.8 19.0 435 CBA-TL110-JU18B
12 7 x 0.67 7.41 0.7 1.8 19.6 500 CBA-TL112-JU18B
19 7 x 0.67 7.41 0.7 1.8 22.8 700 CBA-TL119-JU18B
24 7 x 0.67 7.41 0.7 1.8 26.6 860 CBA-TL124-JU18B
30 7 x 0.67 7.41 0.7 1.9 28.4 1040 CBA-TL130-JU18B
37 7 x 0.37 7.41 0.7 1.9 30.1 1250 CBA-TL137-JU18B
The above data are approximate and subject to normal manufacturing tolerance.Other tpes can be provided on specific request.
We can meet all other standard as BS 5308 and IEC 502.
Fire Resistant CablesMulticores, Layers, Collective Screen, Stranded Conductor
TECHNICAL INFORMATION
UIC
ElsewedyFireResistantCables
8/8/2019 Special Cables Catalogue - El Sewedy Cables
47/126
B 3
Fire Resistant Cables
Applcaton:
These cables are used in re ghting alarm sstems in hazardous area where the safet is highlrequired during re condition.
Engneerng Specfcaton:
Standard:BS-5308
Rated Voltage:300 / 500 V