Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
SORBENT ANALYSIS OF LONG-TERM CO2 CAPTURE TRIALS - PRELIMINARY RESULTS
Jens Emmerich 20.04.2016
WP 1 CONTRIBUTION - OBJECTIVE
Screening of >160 sorbent samples until now to: - - identify stable process conditions
- - select sorbents for in-depth characterization - - feed CFD simulation work based on sorbent analysis
2
Overview
3
Next steps
Preliminary results of sorbent screening
Sorbent screening
Introduction to the Lhoist Business Innovation Center
Introduction to the Lhoist Business Innovation Center
4
• Breakthrough innovations • Incremental improvements
Develop new products & processes
• Lab tests for raw material evaluation & pre-qualification • On-site support for audits and trials
Deliver advanced technical assistance
• Incubator for current and future Talents • Share and secure our core skills with Regions
Maintain, develop and provide a good level of expertise
New product development New process implementation Expertise & knowledge
Raw material qualification Product improvement Process optimization Data acquisition
Industrial scale x 10-100
Pilot scale x 10-100
Lab scale
Industrial scale / 1.000 down to 10.000
Lab scale
Ind. Detention Slaker
Ind. PFR Kiln
Lab Scale Hydrator
Lab Electrical Kiln
SCALE DOWN & SCALE UP APPROACHES
5
Lab Scale Slaker
Introduction to the Lhoist Business Innovation Center
Overview
6
Next steps
Preliminary results of sorbent screening
Sorbent screening
Introduction to the Lhoist Business Innovation Center
7
Sorbent screening Some examples of sorbents
Loop seal samples from test campaign C3 (04/10/2015)
Loop seal samples from test campaign L1 (24/11/2015)
Loop seal samples from test campaign L2 (29/11/2015)
8
Sorbent screening Lab equipment
Determination of the chemical composition of sorbents using the PANalytical / MagiX PRO PW2540 X-ray fluorescence device
Sorbent activity assessment using TGA/DTA tests (Netzsch / STA449)
Automatic Loss on Ignition (LoI) on sorbents to determine res. CO2 on a NAVAS / TGA
Particle size distribution by laser granulometry on a Coulter / LS 13320
Overview
9
Next steps
Preliminary results of sorbent screening
Sorbent screening
Introduction to the Lhoist Business Innovation Center
Coke test campaign C3 Stable operation for 16 h
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
9.00
10.00
11.00
12.00
00:12 02:40 05:15 09:20 13:48 16:00
Test period C3 (04/10/2015) - SO3/CaO and SiO2/CaO ratios
SO3/CaO (LS 4.1)
SO3/CaO (LS 4.5)
SiO2/CaO (LS 4.1)
SiO2/CaO (LS 4.5)
Coke test campaign C3 Stable operation for 16 h
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
0.0
50.0
100.0
150.0
200.0
250.0
300.0
350.0
400.0
450.0
500.0
550.0
600.0
650.0
700.0
750.0
800.0
850.0
900.0
00:12 02:40 05:15 09:20 13:48 16:00
LoI [
% w
/w]
Aver
age
PSD
[um
]
Sampling date and time
Test period C3 - PSD and LoI of SCARLET sorbent samples (04/10/2015)
d90 LS 4.1 - 04/10
d90 LS 4.5 - 04/10
d50 LS 4.1 - 04/10
d50 LS 4.5 - 04/10
res. CO2 LS 4.1 - 04/10
Res. CO2 LS 4.5 - 04/10
Lignite test campaign L1 Stable sorbent after 24 h operation
0.00
0.20
0.40
0.60
0.80
1.00
1.20
17:40:00 04:00:00 08:00:00 15:20:00 20:10:00 09:05:00 13:15:00 16:50:00 21:06:00
Test period L1 (23-25/11/2015) - SO3/CaO and SiO2/CaO ratios
SO3/CaO (LS 4.1)
SO3/CaO (LS 4.5)
SiO2/CaO (LS 4.1)
SiO2/CaO (LS 4.5)
Lignite test campaign L1 Stable sorbent after 24 h operation
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
5.00
0.00
50.00
100.00
150.00
200.00
250.00
300.00
350.00
400.00
450.00
500.00
550.00
600.00
17:40:00 04:00:00 08:00:00 15:20:00 20:10:00 09:05:00 13:15:00 16:50:00 21:06:00
LoI [
% w
/w]
Aver
age
PSD
[um
]
Sampling date and time
Test period L1 - PSD and LoI of SCARLET sorbent samples (23-25/11/2015)
d90 LS 4.1
d50 LS 4.1
d90 LS 4.5
d50 LS 4.5
res. CO2 - LS 4.1
res. CO2 - LS 4.5
Overview
14
Next steps
Preliminary results of sorbent screening
Sorbent screening
Introduction to the Lhoist Business Innovation Center
> TGA and carbon analysis on test period C3 and P2 sorbents for CFD model validation
> Sorbent screening for test campaigns run in Q1/2016
> Integration of results for further project valorization and publication purposes
15
Next steps Tests for CFD model validation and 2016 long-term pilot testing campaigns
Who has the first question ?
16