2012-3-15 CONFIDENTIAL 1
Purpose:
To solve visible skewing problem during paper cut before S/N: 2012W16
Model:
Roll Type P510 series (P510S / Si / K / L)
Symptom:
1. Uneven printout (sample picture is 4x6)
Related symptom might also be caused by the damaged belt as following, so please check
the belt before pasting the pads.
SOP – Skew Problem
NG
2012-3-15 CONFIDENTIAL 2
Also check binder of cable and make sure it is not interfered with metal part.
Necessary Spare Part:
P/N: 59.D0910.002 Cutter_pad_A5
NG
2012-3-15 CONFIDENTIAL 3
Procedure of Rework:
• P510S as an example
[Step 1] Open the DOOR_RIGHT_A5RT, remove 5 screws that hold the right cover
(CASE_RIGHT_A5RT) on the right side.
2012-3-15 CONFIDENTIAL 4
[Step 2] Turn the printer around to the bottom; you’ll see that there are total 13 screws
shown as below picture. Remove 2 screws of right, and then can take off the right
cover (CASE_RIGHT_A5RT). Remove 6 screws both front/back sides, and then take
out front cover (CASE_FRONT_A5RT) and back cover (CASE_BACK_A5RT).
Remove 5 screws of left that hold left cover (CASE_LEFT_A5RT).
[Step 3] Move back to the right side; slide the DOOR_RIGHT_A5RT to front side, then
take off DOOR_RIGHT_A5RT.
2012-3-15 CONFIDENTIAL 5
[Step 4] Now turn the printer to left side, remove 3 screws that hold
CASE_LEFT_A5RT, then take off CASE_LEFT_A5RT.
[Step 5] Remove 2 connectors that connect with power core and POWER BD, remove
1 screw that ground, and then take off CASE_LEFT_A5RT.
2012-3-15 CONFIDENTIAL 6
Total 5 pieces of appearance cover of this printer as shown below:
[Step 6] After take off main cover, remove 6 screws that hold the CASE_TOP_A5RT on the
top side.
2012-3-15 CONFIDENTIAL 7
[Step 7] Remove the 2 cables that connect the CASE_TOP_A5RT and MAIN_BD, then
take off the CASE_TOP_A5RT.
[Step 8] Remove the TQL Device by unscrewing the following 2 screws, there is a spring
hooked on the side, please loosen it.
2012-3-15 CONFIDENTIAL 8
[Step 9] Remove another 2 screws that hold Cutter, and then take off the cutter.
Remove 1 screw from each side Remove 1 screw from each side
2012-3-15 CONFIDENTIAL 9
[Step 10] Unplug the 2 wires that are connected to the mainboard and power extension as
following:
2012-3-15 CONFIDENTIAL 10
[Step 11] Remove the E-rings on both sides of the cutter unit
[Step 12] Remove the springs on both side of the cutter
[Step 13] Slide this bar out of the cutter
2012-3-15 CONFIDENTIAL 11
[Step 14] Take this roller and its plate out
[Step 15] paste the poron pad on these 2 positions
NOTE: these are the parts that have been disassembled
7mm 12mm
2012-3-15 CONFIDENTIAL 12