2
Cable Connector, female A (Part 343665) Connect AC Mains cable Max 0.5—2.5mm2 (20—14 AWG) AC Mains Cable 1 2 L1/N 3 L2 AC Mains Input Terminals Torque: 0.3Nm 4a Cable Connector, female A (Part 343665) AC Mains Cable CW Chameleon Stand-alone Module DC Output Cable CW Cable Connector, male F (Part 343667) Torque: 1.5Nm Torque: 1.5Nm 5a 5b 5c 5d Connect DC Output cable Max 0.4—1.5mm2 (22—16 AWG) DC Output Cable Cable Connector, male F (Part 343667) 1 +0V 2 -48V 3 CAN H 4 CAN L 5 AL-C 6 AL-NO DC Load Output Terminals Torque: 0.4Nm 4b 356849.033 Short Installation Guide Power Supply Module, 48VDC, 650W, HE, IP65 Low Power Outdoor Applications Chameleon Stand-alone Headquarters: Eltek Visitor address: Gråterudveien 8, 3036 Drammen, Norway Phone: +47 32 20 32 00 Fax: +47 32 20 32 10 www.eltek.com Copyright © Eltek 2015 This document may be changed without notice 356849.033, 2v1-2015-08, Published 2015-11-25 This product is CE marked and complies with all current requirements for relevant standards and directives. 4- Connect the Cables to the Connectors Connect the wires of the AC input cable (4a) and the DC output cable (4b) to the cable connectors 5- Connect the Connectors to the Chameleon Module Plug the AC input cable connector to the module (5a), and tighten the cou- pling ring (5b) Plug the DC output cable connector to the module (5c), and tighten the coupling ring (5d) Part 241125.105, Chameleon Module 48V, 650W, HE, IP65 Part 241125.155, Chameleon Module 48V, 650W, HE, IP65, 200ms Part 241125.185, Chameleon Module 48V, 650W, HE, IP65, UI WARNING: Hazardous voltages may be pres- ent inside the Chameleon module, Part # 241125.155, as long as 10 minutes after it is switched OFF (discharge time) Electric Shock 10 min.

Short Installation Guide 356849.033 Chameleon Stand-alone

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Cable Connector,

femaleA (Part 343665)

Connect AC Mains cableMax 0.5—2.5mm2 (20—14 AWG)

AC MainsCable

1

2L1/N

3L2

AC MainsInput Terminals

Torque: 0.3Nm

4a

Cable Connector,female

A (Part 343665)

AC MainsCable

CW

Chameleon Stand-alone Module

DC OutputCable

CW

Cable Connector,maleF (Part 343667)

Torque: 1.5Nm

Torque: 1.5Nm

5a

5b

5c

5d

Connect DC Output cableMax 0.4—1.5mm2 (22—16 AWG)

DC OutputCable

CableConnector,

maleF (Part 343667)

1+0V

2−48V

3CAN H

4CAN L

5AL-C

6AL-NO

DC LoadOutput Terminals

Torque: 0.4Nm

4b

356849.033Short Installation Guide

Power Supply Module, 48VDC, 650W, HE, IP65Low Power Outdoor Applications

Chameleon Stand-alone

Headquarters: EltekVisitor address: Gråterudveien 8, 3036 Drammen, NorwayPhone: +47 32 20 32 00 Fax: +47 32 20 32 10

www.eltek.comCopyright © Eltek 2015 This document may be changed without notice356849.033, 2v1-2015-08, Published 2015-11-25

This product is CE marked and complies with all current requirements for relevant

standards and directives.

4- Connect the Cables to the Connectors Connect the wires of the AC input cable (4a) and the DC output cable (4b) to the cable connectors

5- Connect the Connectors to the Chameleon Module Plug the AC input cable connector to the module (5a), and tighten the cou-pling ring (5b)Plug the DC output cable connector to the module (5c), and tighten the coupling ring (5d)

Part 241125.105, Chameleon Module 48V, 650W, HE, IP65Part 241125.155, Chameleon Module 48V, 650W, HE, IP65, 200msPart 241125.185, Chameleon Module 48V, 650W, HE, IP65, UI

WARNING:

Hazardous voltages may be pres-ent inside the Chameleon module, Part # 241125.155, as long as 10 minutes after it is switched OFF (discharge time)

Electric Shock 10 min.

CircularCross Section

Cable Connectors, femaleB-E (Parts as in table)

Cable Connectors, maleG-J (Parts as in table)

Cable Connector, male

F (Part 343667)

Cable Connector, femaleA (Part 343665)

Insert, malewith Coupling Ring

Sleevewith Pinch Ring

Seal Ring, SR1

Pressing Screw Insert, malewith Coupling Ring

Sleeve

Seal Ring

Pressing Screw

Pinch Ring

Insert, femalewith Coupling Ring

Seal Ring, SR1

Seal Ring, SR2

2 Short Installation Guide • Chameleon Stand-alone, 48VDC, 650W, HE, IP65 Short Installation Guide • Chameleon Stand-alone, 48VDC, 650W, HE, IP65 33568

49.0

33, 2

v1-2

015-

08

Cable Connectors Selection Table

Cable Type Cable Connector Type

Function Outer Diameter, mm

Connector Type Eltek’s Part No.

Binder’s Part Number Pressing Screw’s Torque, Nm

Input 12—177.0—13

A Input Connector (SR1)Input Connector (SR2)

343665 99-4222-300-04 (3+PE) 1.6 —2.00.8 —1.4

Input 6.0—9.5 B Input Connector 334321 99-4222-00-04 (3+PE) 0.8 —1.0

Input 8—10 C Input Connector 334322 99-4222-110-04 (3+PE) 1.0 —1.4

Input 10—12 D Input Connector 334323 99-4222-14-04 (3+PE) 1.0 —1.4

Input 12—14 E Input Connector 314804 99-4222-160-04 (3+PE) 1.0 —1.4

Output 12—177.0—13

F Output Connector (SR1)Output Connector (SR2)

343667 99-4217-300-07 (6+PE) 1.6 —2.00.8 —1.4

Output 6—8 G Output Connector 334328 99-4217-00-07 (6+PE) 0.8 —1.0

Output 8—10 H Output Connector 334329 99-4217-110-07 (6+PE) 1.0 —1.4

Output 10—12 I Output Connector 334330 99-4217-14-07 (6+PE) 1.0 —1.4

Output 12—14 J Output Connector 314805 99-4217-160-07 (6+PE) 1.0 —1.4

3- Select Correct Cable Connectors Select the cable connector type that corresponds to your cable’s outer diameter, ±0.2 mm

Table 1. Selection of Cable Connectors

Important Information The product warranty becomes invalid if the following safety precautions are not followed during handling, installation and commissioning of this equipment.

1- Fasten the Chameleon Module to a Surface or Pole Refer to the downloaded Quick Installation Guide Chameleon Stand-alone, Doc 356849.103

2- Select Correct Type of CablesSelect suitable type of cables with circular cross section

CAUTION:

— For safety reasons, the commissioning and configuration of the equipment is only to be performed by authorized and qualified persons.

— Please, download the Quick Installation Guide Chameleon Stand-alone — Doc 356849.103 — from www.eltek.com, and read it carefully before installing and using the equipment, as installation and operation is to be performed as described in it. Always tight-en screws and bolts with the torque values recommended in the guide.

Qualified Personnel

!

CAUTION:

— If used as PERMANENTLY CONNECTED, a readily accessible disconnect device shall be in-corporated external to the equipment; If used as PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be easily accessible.

— Maximum operational ambient temperature of this equipment is 60°C or, if installed in a RESTRICTED ACCESS LOCATION, 70°C

Device Hazard

!

CAUTION:

— To avoid corrosion of the screw terminals and field failures not covered by the warranty, always use cables with circular cross section, and cable connectors and seal rings suitable for the cable’s outer diameter

— The cable connectors in Table 1 are suitable for PUR and PVC type cables with circular cable cross section

Device Hazard

!

WARNING:

— For safety reasons (high leakage current / high touch current) you must always con-nect the AC earth wire (PE) to the terminals, before you connect the AC input cable(s).

— Be cautious! Double Pole / Neutral Fusing (fuses installed both in Live and Neutral)

Electric Shock

WARNING:

For outdoor applications where the product may be subject to transient overvoltages exceeding those for Overvoltage Category II, an AC Overvoltage Protection Device (OVP) complying with IEC 61643-series must be installed on the AC supply. This device will re-duce the overvoltages to levels corresponding to Overvoltage Category II

Over-Voltage Protection

WARNING: Wrong cable connector leads to field failure not covered by the warranty!

Device Hazard