Bulletin 947676 THE OILGEAR COMPANY 1
SERVICE INSTRUCTIONS“P-1NN/F” SINGLE PRESSURE
COMPENSATOR WITH LOAD SENSE FOR PVG-150 PUMP, A1 SERIES CONTROL
Figure 1. Typical Oilgear Type “P-1NN/F” Single Pressure Compensator w/Load Sense Control for PVG-150 Pumps
PURPOSE OF INSTRUCTIONSThese instructions will simplify the installation,operation, troubleshooting and maintenance ofO i lgear t ype “P -1NN/F” S ing le PressureCompensator w/Load Sense controlled units.
This material will inform you about the basicconstruction, principle of operation and serviceparts listings. Some controls may be modified forspecific applications from those described in thisbulletin and other changes may be made withoutnotice.
REFERENCE MATERIALFluid Recommendations .......................................................................................Bulletin 90000Contamination Evaluation Guide............................................................................Bulletin 90004Filtration Recommendations .................................................................................Bulletin 90007Piping Information .................................................................................................Bulletin 90011Installation of Vertically Mounted Axial Piston Units .............................................Bulletin 90014PVG Pumps -150 Service Instructions.................................................................Bulletin 947034PVG Open Loop Pumps, Sales ..........................................................................Bulletin 47019-J
PVG-150 PUMP INSTALLATIONSSingle Pressure Compensator w/Load Sense “P-1NN/F,” Installation............. Data Sheet 47378Basic Pump, Installation.................................................................................. Data Sheet 47375Through Shaft Basic Pump, Installation .......................................................... Data Sheet 47376Gear Pump, Installation................................................................................... Data Sheet 47945Dual Pump 2-Bolt SAE Adapters, Installation ................................................. Data Sheet 47387Dual Pump 4-Bolt SAE Adapters, Installation ................................................. Data Sheet 47388
OILG0484
Bulletin 947676
Issued: February 2010
THE OILGEAR COMPANY2300 South 51st Street
Milwaukee, Wisconsin 53219www.oilgear.com
Bulletin 947676
2 THE OILGEAR COMPANY Bulletin 947676
Read and understand this entire instruction sheetbefore repairing or adjusting your Oilgear product.
Those who use and maintain this equipment mustbe thoroughly trained and familiar with the product.If incorrectly used or maintained, this product andits equipment can cause severe injury.
SAFETY SYMBOLSThe following signal words are used in thisinstruction sheet to identify areas of concern whereyour safety may be involved. Carefully read the textand observe any instructions provided to ensureyour safety.
THIS SIGNAL WORD INDICATES AN IMMI-NENTLY HAZARDOUS SITUATION WHICH,IF NOT AVOIDED, WILL RESULT IN DEATHOR SERIOUS INJURY.
This signal word indicates a potentiallyhazardous situation which, if not avoided,could result in death or serious injury.
This signal word indicates that a potentiallyhazardous situation exists which, if notavoided, may result in damage toequipment or minor personal injury.
While not directly relevant to the topic beingdiscussed, the NOTE is used to emphasizeinformation provided, or provide additionalinformation which may be of benefit.
This service information is designed forthe maintenance of your Oilgear product.It contains the information on the correctprocedures determined by Oilgear for thesafe manner of servicing. Always keepthis instruction sheet in a location where itis readily available for the persons whouse and maintain the product. Additionalcopies of this instruction sheet areavailable through Oilgear. Contact us at414-327-1700 or visit our website:www.oilgear.com. Please contact us if youhave any questions regarding theinformation in this instruction bulletin.
The cleanliness of working on this pumpcontrol or the hydraulic system is extremelyimportant to the safety and reliability of thepump and the system. Always make surethe fittings are clean on the outside beforeremoving them from their connections, arecapped and plugged when removed, andare placed in a clean rag or container untilthey are reinstalled.
Some service operations may requirespecial tools or equipment. If you requireinformation on these items, please contactOilgear before attempting these repairsand service operations.
Read, understand and follow the safetyguidelines, dangers and warningscontained in this instruction sheet topromote reliable operation and preventserious personal injury.
DO NOT attempt to service this machineryin an environment where safety regulationsare not established and in place.
DO NOT operate the hydraulic system if aleak is present. Serious injury may result.
Hydraulic systems operate under very highpressure. Hydraulic fluid escaping from apressurized system can penetrateunprotected body tissue. DO NOT inspectfor hydraulic leaks with bare hands or otherexposed body parts. As a minimum, wearleather gloves prior to inspecting for leaksand use cardboard or wood. If leaks arepresent, relieve pressure and allow systemto cool prior to servicing. If injured byescaping hydraulic oil, contact a physicianimmediately. Serious complications mayarise if not treated immediately. If you havequestions regarding inspecting forhydraulic leaks, please contact Oilgearprior to servicing.
DANGER! !
! WARNING
CAUTION
NOTE
! WARNING
NOTE
! WARNING
! WARNING
! WARNING
! WARNING
! WARNING
Safety First
© 2010 THE OILGEAR COMPANY - ALL RIGHTS RESERVED
Bulletin 947676 THE OILGEAR COMPANY 3
Hydraulic hoses and tubing must beinspected on a daily basis for leaks, cuts,abrasions, damage and improperclearance along any mounting frame forhidden damage before the unit is put intoservice. Replace damaged hoses or hosesyou suspect are damaged before thesystem is returned to service! Hoses mustbe replaced every 2 years. Failure toproperly inspect and maintain the systemmay result in serious injury.
Hydraulic systems are hot. DO NOTTOUCH! Serious personal injury mayresult from hot oil. When you havecompleted working on the hydraulicsystem, thoroughly clean any spilled oilfrom the equipment. Do not spill anyhydraulic fluids on the ground. Clean anyhydraulic fluids from your skin as soon asyou have completed maintenance andrepairs. Dispose of used oil and systemfilters as required by law.
Use hoses, fittings and adapters with thecorrect SAE rating when replacing hosesto prevent possible serious injury. Alwaysreplace hoses, fittings and adapters withreplacements that have a proper, suitable,working pressure rating. Replacementhoses must be of the correct length andmust comply with the hose manufacturer’sand Oilgear’s installation guidelines andrecommendations.
Hydraulic hoses have the SAE ratingsmarked on the hose to assist you inselecting the correct hose. The samemanufacturer must supply any replacementhydraulic hoses and fitting assemblies. Asan example: Brand “X” hose and brand “Y”fitting will not normally be compatible. No“Twist” is allowed in the hydraulic hoses.“Twist” may result in premature hosefailure. This can cause serious injury.Please contact Oilgear for assistance whenrequired.
Hydraulic cylinders can be holding afunction in a certain position when thepump is off. An example of this is afunction being held in the lift or partial liftposition by the cylinders. If a hydraulicline is removed or the hydraulic circuits orcontrols are being worked on, gravity mayallow the function being held in position todrop. All workers and personnel mustremain clear of these areas when workingon or operating the hydraulic system.Block and secure all devices andfunctions which apply before beginningwork or operation. Failure to comply withthis can result in serious injury or death.
Any hydraulic pipe which is replaced mustconform to SAE J1065 specifications. Ifincorrect hydraulic pipe is installed, thehydraulic system may fail, causingserious injury. Damaged or leakingfittings, pipes or hoses must be replacedbefore the system is returned to service.
DO NOT heat hydraulic pipe. The carboncontent of this steel tube is such that ifheated for bending, and either water or airquenched, the pipe may lose its ductilityand thereby be subject to failure underhigh pressure conditions. Serious injurycan result. Damaged or leaking pipes mustbe replaced before the system is returnedto service. Please contact Oilgear if yourequire assistance or have questions.
All hydraulic pressure must be relievedfrom the hydraulic system prior to removingany components from the system. Torelieve the hydraulic pressure from thehydraulic system, turn off the motor andoperate the control panel with the key in theON position. Failure to comply can result inserious injury. If you have any questionsconcerning relieving the hydraulic pressurefrom the system, please contact Oilgear.
! WARNING
! WARNING
! WARNING
! WARNING
! WARNING
! WARNING
! WARNING
! WARNING
Safety First
4 THE OILGEAR COMPANY Bulletin 947676
Hydraulic components can be heavy. Usecaution while lifting these components.Serious personal injury can be avoidedwith proper handling of the components.
Please contact Oilgear if you requireassistance. When performing hydraulictest procedures, use the proper hydraulicgauges. Installing an incorrect test gaugecould result in serious injury if the gaugefails. Use properly rated hydraulic hosesto allow the test gauge to be read awayfrom moving parts and functions.
Increasing hydraulic pressure beyond therecommendations may result in seriousdamage to the pump and system orserious personal injury, and may void theOilgear Warranty. If you have questionsconcerning hydraulic pressures or testingprocedures, please contact Oilgear beforeattempting the test procedures or makingadjustments.
An Oilgear pump or pump control mustnot be modified in any way withoutauthorization from Oilgear. Modificationsmay not comply with safety standards,including ANSI safety standards, and mayresult in serious personal injury. Pleasecontact Oilgear if you require assistance.
DO NOT enter under hydraulic-supportedequipment unless it is fully supported orblocked. Failure to follow this procedurecan result in serious injury or death.
Any Oilgear pump safety decals must bereplaced anytime they are damaged,missing or cannot be read clearly. Failureto have proper decals in place can resultin serious injury or death. (If you requiresafety decals, please contact Oilgear forreplacement safety decals, at no charge.)
Be sure everyone is clear of the areaaround the hydraulic system beforeoperating after servicing. Remain attentiveat all times when operating to check yourwork until you are completely sure it issafe to return to service. Failure to heedthis warning may result in seriouspersonal injury or death.
Wear the proper protective clothing whenoperating, servicing or maintaining thehydraulic system or the Oilgear pump. Wearthe correct protective gear, safety glasses,gloves and safety shoes. Serious injury canresult without proper protective gear.
Make sure to keep hands, feet and otherparts of your body clear of revolving ormoving parts. Failure to comply can causeserious injury.
DO NOT wear watches, rings or jewelrywhile working with electrical and mechani-cal equipment. These items can be hazard-ous and can cause serious and painfulinjuries if they come into contact with elec-trical wires, moving parts or hydraulicequipment.
! WARNING
! WARNING
! WARNING
! WARNING
! WARNING
! WARNING
! WARNING
! WARNING
! WARNING
! WARNING
Safety First
Bulletin 947676 THE OILGEAR COMPANY 5
Figure 2. ASA Diagram for “P-1NN/F” Control Shown with Typical Pump
Figure 3. Curve Indicating Flow Versus Pressure for “P-1NN/F” Type Control
LSOP 9
A
1B
GPA
OP 1 OP 2
OP 6
OP 3 OP 4
OP 8RP1
1A
OP 14
OILG0334
PRESSURE
FL
OW
OILG0384
6 THE OILGEAR COMPANY Bulletin 947676
TROUBLESHOOTINGPROBLEM CAUSES REMEDY
Unresponsive or Unstable Control
Swashblock bearing surface and/or saddle bearings worn or damaged
Refer to 947034 Pump Service Instructions.
Fluid is contaminatedInspect and clean if necessary. Refer to FiltrationRecommendations Bulletin 90007.
Damaged or sticking load sense spool
Inspect and clean if necessary. Replace damaged parts.
Contamination trapped between control piston and bore not allowing piston to move smoothly
Contamination trapped between control spool and bore not allowing spool to move smoothly
Insufficient control flow Increase size of control orifice “OP 6.”
Worn or damaged pilot relief seat and/or poppetInspect and replace if necessary.
Faulty remote function circuit
Hydraulic line between remote fuction and pump port RP1 is incorrect
Change hydraulic line.
Insufficient Outlet Volume
Improper load sense adjustment Adjust load sense CW to increase flow.
Swashblock bearing surface and/or saddle bearings worn or damaged
Refer to 947034 Pump Service Instructions.
Low input drive speed
Worn cylinder barrel and/or valve plate mating surfaces
Failed drive shaft
Worn or damaged piston shoes and/or swashblock
Worn pistons and/or piston bores
Maximum volume stop adjusted incorrectly Adjust maximum volume stop CCW to increase flow.
Pressure compensator is set too close to operating pressureAdjust pressure compensator CW to increase pressure.
Control piston stuck off strokeInspect and replace if necessary.
Faulty remote function circuit
Unable to Develop Full Pressure
System requires more flow than available Check system for leaks or open functions.
Pressure compensator adjustment not set correctlyAdjust pressure compensator CW to increase pressure.
Contamination in control spoolInspect and clean if necessary.
Contamination in load sense spool
Worn or damaged pilot relief seat and/or poppet
Inspect and replace if necessary.Control piston stuck off stroke
Faulty remote function circuit
Excessive Pressure
Swashblock bearing surface and/or saddle bearings worn or damaged
Refer to 947034 Pump Service Instructions.
Pressure compensator adjustment not set correctlyAdjust pressure compensator CCW to decrease pressure.
Contamination in “OP 3” or “OP 4”Inspect and clean if necessary.
Restricted passage between outlet and control spool
Contamination trapped between control piston and bore not allowing piston to move smoothly Inspect and clean if necessary. Replace damaged
parts.Contamination trapped between control spool and bore not allowing spool to move smoothly
Faulty remote function circuit Inspect and replace if necessary.
Bulletin 947676 THE OILGEAR COMPANY 7
PRINCIPLE OF OPERATIONOperation for a typical pump is described. Sectiondiagrams are a representation of typical pumpswith “P-1NN/F” control.
Functionally, the swashblock (and resultantdisplacement) is positioned by two opposite actingcontrol pistons (unloading control piston and biascontrol piston).
See control parts drawing for actual configurationand loca t ion o f par t assembl ies, or i f i ces,connections and ports.
STARTING
The bias spring (329) positions the control pistonsand connected pump swashblock so that the pumpis at maximum displacement to raise pressure inthe system.
8 THE OILGEAR COMPANY Bulletin 947676
RAISING PRESSURE - LOADING
Pump outlet pressure is ported to the controlthrough Port “OP 1” to the control spool (305) andto the bias control piston (303). Outlet pressure isalso transmitted through orifice Port “OP 2,”allowing the pressure acting on either end of thecontrol spool (305) to be equal. In this condition,the control spool (305) is held in position only bythe spring (328).
The outlet pressure through Port “OP 2” is furthertransmitted through Port “OP 3” and Port “OP 4” tothe adjustable pressure compensator relief valveand to the load sense spool (353).
The load sense spool (353) is held in theclosed position by both a spring (355), andthe load pressure (P2) piped to the springchamber.
NOTE
Bulletin 947676 THE OILGEAR COMPANY 9
Figure 4. Raising Pressure - Loading
TOSYSTEM
UNLOADINGCONTROL
BIASCONTROL
OP 4
OP 3OP 2
OP 14OPTIONAL
OP 1
OP 6
FLOW CONTROLVALVE
P1 P2
LS
OP 8
OP 9OPTIONAL
CONTROL PIN
SWASHBLOCK(329)
(303)
(353)
(355)
PRESSURECOMPENSATORRELIEF VAVLE
(328)
(305)
OILG0479
10 THE OILGEAR COMPANY Bulletin 947676
LOAD SENSE CONTROL - UNLOADING
The load sensing module matches flow to loaddemand. As the load on the system increases,pump pressure will increase while keeping the flow(volume) constant. The load sense spool (353)senses and maintains a constant pressuredifferential across the flow control valve in thedelivery line. Pump flow becomes a function of theflow control valve opening area. For a given flowcontrol valve setting, the pump will maintain aconstant flow regardless of changes in pump inputspeed and/or working pressure.
As differential pressure across the flow controlvalve increases, the pressure differential across theload sense spool (353) increases, causing the loadsense spool (353) to shift and allow flow throughthe load sense valve to drain. Pressure on thespring end of the control spool (305) is decreased,causing a pressure differential across the spool(305). The pressure differential forces the controlspool (305) to shift and compress the spring (328).Outlet pressure is then ported to the unloadingcontrol piston (302), and fluid behind the biascontrol piston (303) is ported to drain. Pumpdisplacement will decrease until differentialpressure across the flow control valve reaches thesetting of the load sense valve.
As differential pressure across the flow controlvalve decreases, the pressure differential acrossthe load sense spool (353) decreases, causing theload sense spool (353) to shift and close off thepath to drain. Pressure on either side of the controlspool (305) will become equal and the spring (328)will force the spool (305) to shift. Fluid from theunloading control piston (302) is then ported todrain and outlet pressure is ported to the biascontrol piston (303). Pump displacement willincrease until the differential pressure across theflow control valve reaches the setting of the loadsense valve.
Bulletin 947676 THE OILGEAR COMPANY 11
Figure 5. Load Sense Control - Unloading
TOSYSTEM
UNLOADINGCONTROL
BIASCONTROL
OP 4
OP 3OP 2
OP 14OPTIONAL
OP 1
OP 6
FLOW CONTROLVALVE
LS
OP 8
OP 9OPTIONAL
CONTROL PIN
SWASHBLOCK
(302)(303)
(353)
(328)
(355)(305)
OILG0480
12 THE OILGEAR COMPANY Bulletin 947676
COMPENSATING PRESSURE - UNLOADING
When pressure on the relief valve poppet (307)exceeds the presetting of the relief valve spring(327), the relief valve poppet (307) moves off seat(308) and allows flow through the relief valve todrain. Pressure on the spring end of the controlspool (305) is decreased, causing a pressuredifferential across the spool (305). The pressuredifferential forces the control spool (305) to shiftand compress the spring (328). Outlet pressure isthen ported to the unloading control piston (302),and fluid behind the bias control piston (303) isported to drain. Pump displacement will decreaseto maintain system pressure as set by the reliefvalve adjuster (310).
HOLDING PRESSURE
If the system pressure drops below the presetcompensating pressure, the relief valve poppet(307) seats and closes the path to drain. Pressureon either side of the control spool (305) willbecome equal and the spring (328) will shift thespool (305) to the original position (Figure 4).Fluid from the unloading control piston (302) isthen ported to drain and outlet pressure is portedto the bias control piston (303). Pumpdisplacement will increase until the relief valvesetting is reached again.
ORIFICE FUNCTIONS
“OP 1” Orifice not used (standard)
“OP 2” Integral to spool, item 305
“OP 4” Integral to seat, item 308
“OP 6” .089 orifice
“OP 8” Orifice not used (standard)
“OP 14” Orifice not used (standard)
OrificeNumber
Decreasing orifice diameter will result in: (increasing diameter
will do the opposite)
“OP 1” Decreased “off stroke” time, do not decrease to less than .125"
“OP 2” Do not change“OP 3” Do not change“OP 4” Do not change“OP 6” Decreased stability“OP 8” Increased stability“OP 9” Optional
“OP 14” Decreased “on stroke” time, do not decrease to less than .081"
Bulletin 947676 THE OILGEAR COMPANY 13
Figure 6. Compensating Pressure - Unloading
TOSYSTEM
UNLOADINGCONTROL
BIASCONTROL
OP 4(308)
OP 3OP 2
OP 14OPTIONAL
OP 1
OP 6
FLOW CONTROLVALVE
LS
OP 8
OP 9OPTIONAL
(310)
(328)
(327)(307)
(305)
CONTROL PIN
SWASHBLOCK
(302)(303)
OILG0481
14 THE OILGEAR COMPANY Bulletin 947676
SCREW AND PLUG TORQUES FOR PVG-150 “P-1NN/F” CONTROL
CONTROL O-RING SEALS
* Teflon Backup Ring** 90 durometer viton seals used
Item Number Head Type & Hex Size Tightening Torque
306 7/8 external 50 ft•lb (68 N•m)
308 7/16 external 200 in•lb (23 N•m)
309 1 external 80 ft•lb (108 N•m)
315A 3/8 internal 100 ft•lb (136 N•m)
315B 3/8 internal 100 ft•lb (136 N•m)
316 3/8 internal 100 ft•lb (136 N•m)
319 5/32 internal 48 in•lb (5 N•m)
321 3/16 internal 120 in•lb (14 N•m)
322 7/8 external 50 ft•lb (68 N•m)
323 1 1/4 external 120 ft•lb (163 N•m)
325 5/32 internal 48 in•lb (5 N•m)
342 1/8 internal 45 in•lb (5 N•m)
351 1 1/4 external 85 ft•lb (115 N•m)
354 5/8 external 70±10 in•lb (8±1 N•m)
356 5/32 internal 57 in•lb (6 N•m)
364 3/32 internal 20 in•lb (2 N•m)
720 1 1/4 external 120 ft•lb (163 N•m)
Item Number ARP 568 Uniform Size Number Shore A Durometer
Viton HNBR EPR
314 -140 70 75 80
330 -013 90 90 80
331 -014 90 90 80
333 -906 90 90 80
334 -908 90 90 80
335 -910 90 90 80
336 -912 90 90 80
337 -014 * * *
338 -904 90 90** 80
345 -903 90 90** 80
358 -010 90 90 80
359 -016 90 90 80
360 -906 90 90 80
361 -912 90 90 80
362 -014 90 90 80
399 -014 * * *
1014 -014 90 90 80
1912 -912 90 90 80
Bulletin 947676 THE OILGEAR COMPANY 15
PARTS LIST FOR PVG-150 “P-1NN/F” CONTROLParts used in these assemblies are per Oilgearspecifications. Use only Oilgear parts to ensurecompatibility with assembly requirements. Whenordering replacement parts, be sure to includepump type and serial number, and bulletin numberand item number. Specify the type of hydraulic fluidto ensure seal and packing compatibility.
Item Description Qty Item Description Qty301 Control Housing 1 335 O-ring 1302 Unloading Control Piston 1 336 O-ring 1303 Bias Control Piston 1 337 Backup Ring 1304 End Cap 1 338 O-ring 2305 Control Spool 1 340 Permanent Plug 2306 End Plug, Spring End 1 342 SAE #3 Plug 1307 Relief Valve Poppet 1 345 O-ring 2308 Seat 1 348 Roll Pin 4309 Pilot Relief Bonnet 1 350 Load Sense Module 1310 Relief Valve Adjuster 1 351 Load Sense Bonnet 1312 Shim 4 352 Load Sense Adjusting Screw 1314 O-ring 1 353 Load Sense Spool 1
315A Screw 2 354 Load Sense Seat 1315B Screw 1 355 Spring 1316 Screw 4 356 Screw 4318 Jam Nut 1 358 O-ring 3319 Orifice 1 359 O-ring 2321 SAE #4 Plug 2 360 O-ring 1322 Filter End Plug 1 361 O-ring 1323 Maximum Volume Plug 1 362 Backup Ring 2325 Orifice 1 364 Setscrew 1327 Relief Valve Spring 1 365 Jam Nut 1328 Bias Spring 1 399 Backup Ring 1329 Bias Spring 1 718 Maximum Stop Adjusting Screw 1330 O-ring 3 719 Jam Nut 1331 O-ring 1 720 Maximum Stop Bonnet 1333 O-ring 1 1014 O-ring 1333 O-ring 1 1912 O-ring 1334 O-ring 2
16 THE OILGEAR COMPANY Bulletin 947676
PVG-150 P-1NN/F Control Service KitsReference: 520167-102 Ass’y Drwg
Document Number: 520167-SK2
Revision: 0
Sheet 1 of 1
Description Kit No.Design Series Items Included (quantity is 1 unless noted)
Control Pistons & SpringAll K318946-001 A1 302, 303, 329
Pressure Compensator ReliefViton Seals L723987-101
A1 307, 308, 312(4), 327, 333HNBR Seals L723987-104EPR Seals L723987-103
Load Sense & Press. Comp. ReliefViton Seals L723987-108
A1 307, 308, 312(4), 327, 333, 353, 354, 355, 359(2), 360, 362(2)HNBR Seals L723987-111
EPR Seals L723987-110
Pressure Compensator SpoolAll L724407-002 A1 305, 328
Pressure Compensator AdjusterViton Seals L300574HS04
A1 309, 310, 318, 331, 335, 337HNBR Seals L300574HS10
EPR Seals L300574HS06
Load Sense AdjusterViton Seals L318966-002
A1 351, 352, 359, 361, 362, 365HNBR Seals L318966-005EPR Seals L318966-004
Adjustable Maximim Volume StopViton Seals L516319-006
A1 399, 718, 719, 720, 1014, 1912HNBR Seals L516319-007
EPR Seals L516319-008
Control Seal KitViton Seals K516336-023
A1314, 330(3), 331, 333, 334(2), 335, 336, 337, 338(2), 345(2), 358(3), 359(2), 360, 361, 362(2), 399, 1014, 1912
HNBR Seals K516336-024
EPR Seals K516336-025
End Cap AssemblyViton Seals K520143-104
A1303, 304, 305, 306, 307, 308, 309, 310, 312(4), 314, 315A(2), 315B, 318, 321(2), 322, 325, 327, 328, 330(3), 331, 333, 334(2), 335, 337, 338(2), 340(2), 348(4)
HNBR Seals K520143-105
EPR Seals K520143-106
Load Sense ModuleViton Seals L723004-001
A1350, 351, 352, 353, 354, 355, 356(4), 358(3), 359(2), 360, 361, 362(2), 364, 365
HNBR Seals L723004-817
EPR Seals L723004-803
Bulletin 947676 THE OILGEAR COMPANY 17
Figure 7. Exploded Parts Drawing for PVG-150 “P-1NN/F” Single Pressure Compensator w/Load Sense Control (520167-102 sheet 1)
OP2
OP3
OP4
RP1
360
362
OP9
OP1
4(E
ND C
AP F
ACE)
306
334
328
321
338
321
338
358
348
325
315B
315A
304
350
356
354
359
353
355
352
351
361
365
359
362
340
358
348
308
333
307
312
327
310
309
335
318
305 32
2 33
4
314
303
329
302
348
OP1
(END
CAP
FAC
E)
OP8
(END
CAP
FAC
E)
364
331
337
ADJU
STAB
LE M
AXIM
UM V
OLU
ME
STO
P 719
718
399
720
1912
1014
FIXE
D M
AXIM
UMVO
LUM
E ST
OP
342
345
323
336
301
316
342
345
319
330
OP6
OIL
G04
82
18 THE OILGEAR COMPANY Bulletin 947676
Figure 8. Cross Section Parts Drawing for PVG-150 “P-1NN/F” Single Pressure Compensator Control (520167-102 sheet 2)
BB
A A
OP2
OP3
OP4
OP6
FIXE
D M
AXIM
UMVO
LUM
E ST
OP
342
345
319
SECT
ION
B-B
356
348
323
336
314
303
302
329
301
316
SECT
ION
A-A
SEE
DETA
IL C
SEE
DETA
IL D
SEE
DETA
IL E
321
338
354
350
353
355
351
361
365
352
308
333
325
306
334
328
322
334
305
309
335
310
312
327
318
307
304
RP
1
315B
321
338
315A
DETA
IL C
360
362
359
DETA
IL D
359
362
DETA
IL E
331
337
SEE
DETA
IL A
720
718
1912
719
ADJU
STAB
LE M
AXIM
UM V
OLU
ME
STO
P
DETA
IL A
1014
399
OIL
G04
83
Bulletin 947676 THE OILGEAR COMPANY 19
NOTES____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
20 THE OILGEAR COMPANY Bulletin 947676
AFTER SALES SERVICESAt Oilgear we build products to last. It is the natureof this type of machinery to require propermaintenance regardless of the care we put intomanufactur ing. Oilgear has several serviceprograms in place to help you.
STAY-ON-STREAM SERVICE
By signing up for Oilgear’s Stay-On-Streamprogram, you can prepare for problems before theyhappen. Certain field tests such as fluid testing,slip testing and electronic profile recordingcomparisons can be performed by our field servicepeople or your own factory trained personnel.These tests can indicate problems before theybecome “down-time” difficulties.
SERVICE SCHOOLS
Oilgear conducts training to train your maintenancepersonnel. “General” hydraulic or electronictraining is conducted at our Milwaukee, Wisconsinplant on a regular basis. “Custom” training,specifically addressing your particular hydraulicand electro-hydraulic equipment, can be conductedat your facilities.
SPARE PARTS AVAILABILITY
Prepare for your future needs by stocking Oilgearoriginal factory parts. Having the correct parts andnecessary skills “in-plant” enables you to minimize“down-time.” Oilgear has developed parts kits tocover likely future needs. Oilgear Field ServiceTechnicians are also ready to assist you and yourmaintenance people in troubleshooting andrepairing equipment.
THE OILGEAR COMPANY2300 South 51st Street
Milwaukee, Wisconsin 53219www.oilgear.com
Issued: February 2010