2
Series: iMOD™ Features: n Built with patented THiNCAPS™ n Front terminal connections n 4U height n 3 wide 19” rack 4 wide 23” rack Applications: n Power conditioning n Short term UPS n Ride though power/voltage hold up n Long life Markets: n Power correction n Information systems n Critical systems n Hospitals n Silicon production n Telecommunications n Renewable energy n Food production Markings: Products are marked with the following: Rated capacitance, rated voltage, product number, name of manufacturer, positive and negative terminal marking. www.ioxus.com | [email protected] Operating Voltage, Rated Voltage, Surge Capacitance Tolerance Temperature Range, Operational Range, Storage Life DC Endurance Shelf Cycle Standards Compliance 2.7 V/Cell 2.85 V/Cell +10% / -0% 0 o C to 50 o C (At Rated Current) -25 o C to 60 o C 10 years, rated voltage, 25 o C ∆C<20% decrease, ESR<100% increase 1000 hrs, rated voltage, 70 o C ∆C<20% decrease, ESR<100% increase 1000 hrs, no voltage, 70 o C ∆C<20% decrease, ESR<100% increase >500,000 cycles, Rated to half rated voltage, 25 o C ∆C,20% decrease, ESR, 100% increase RoHS

Series: iMOD™ - Ioxus · 2015-06-25 · Series: iMOD™ Features: n Built with patented THiNCAPS™ n Front terminal connections n 4U height n 3 wide 19” rack 4 wide 23” rack

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Series: iMOD™ - Ioxus · 2015-06-25 · Series: iMOD™ Features: n Built with patented THiNCAPS™ n Front terminal connections n 4U height n 3 wide 19” rack 4 wide 23” rack

Series: iMOD™Features:n Built with patented THiNCAPS™ n Front terminal connections n 4U height n 3 wide 19” rack 4 wide 23” rack

Applications:n Power conditioning n Short term UPS n Ride though power/voltage hold up n Long life

Markets:n Power correction n Information systems n Critical systems n Hospitals n Silicon production n Telecommunications n Renewable energy n Food production

Markings:Products are marked with the following: Rated capacitance, rated voltage, product

number, name of manufacturer, positive

and negative terminal marking.

www.ioxus.com | [email protected]

Operating

Voltage, Rated

Voltage, Surge

Capacitance Tolerance

Temperature

Range, Operational

Range, Storage

Life

DC

Endurance

Shelf

Cycle

Standards Compliance

2.7 V/Cell

2.85 V/Cell

+10% / -0%

0oC to 50oC (At Rated Current)

-25oC to 60oC

10 years, rated voltage, 25oC

∆C<20% decrease, ESR<100% increase

1000 hrs, rated voltage, 70oC

∆C<20% decrease, ESR<100% increase

1000 hrs, no voltage, 70oC

∆C<20% decrease, ESR<100% increase

>500,000 cycles, Rated to half rated voltage, 25oC

∆C,20% decrease, ESR, 100% increase

RoHS

Page 2: Series: iMOD™ - Ioxus · 2015-06-25 · Series: iMOD™ Features: n Built with patented THiNCAPS™ n Front terminal connections n 4U height n 3 wide 19” rack 4 wide 23” rack

41.5

22

No

81

85.5

870

23

3600

Passive

38

3.8

3.7

7.5

7.4

3.0

125

463.6

168

10

10

41.5

22

Yes

81

85.5

870

23

3600

Passive

38

3.8

3.7

7.5

7.4

3.0

125

463.6

168

10

10

20.8

45

No

162

171

870

31

3600

Passive

76

3.7

3.6

6.3

7.1

3.6

125

942.2

168

23

20

18 Stadium Circle, Oneonta, NY 13820, USA

Toll Free: +1.877.751.4222

607.441.3500 | Fax: 607.433.9014

www.ioxus.com | [email protected]

© 2012 Ioxus, Inc. | 121008

Part Number iMOD081V042P3L-00A

Electrical

Capacitance (F)

ESR, DC ≤(mΩ) [3ms]

Overvoltage Monitor

Voltage Rated (V)

Peak Voltage

Cycling

Current, Peak [1s] (A)

Continuous Current (A)*

Current, Short Circuit (A)

Management

Balancing Method

Energy/Power

Emax (Whr)

Emax (Whr/kg)

Emax (Whr/L)

Pmax (kW/kg)

Pmax (kW/L)

Pd (kW/kg)

Physical

W (mm) [max]

L (mm) hole center to H.C.

H (mm)

Mass (kg)

Volume (L)

Product Specifications

Additional Technical Information

Product specification test methods available in separate document.

*Rated current = continuous current with 20oC temperature rise.

iMOD081VO42P3L-02A iMOD162V021P3L-00A