4
ADIRONDACK AIRE Series CEC Singer / McQuay C/EC and IslandAire EC Application Flexible Fast and Easy Replacement Damage Protection

Series CEC - Cold Point Corporation AIRE Series CEC Singer / McQuay C/EC and IslandAire EC Application Flexible Fast and Easy Replacement Damage Protection

Embed Size (px)

Citation preview

Page 1: Series CEC - Cold Point Corporation AIRE Series CEC Singer / McQuay C/EC and IslandAire EC Application Flexible Fast and Easy Replacement Damage Protection

A D I R O N D A C K A I R E

Series CECSinger / McQuay C/EC and IslandAire ECApplication Flexible Fast and Easy Replacement Damage Protection

Page 2: Series CEC - Cold Point Corporation AIRE Series CEC Singer / McQuay C/EC and IslandAire EC Application Flexible Fast and Easy Replacement Damage Protection

ADIRONDACK-AIRE CEC CHASSIS SERIES

The Adirondack-Aire CEC series zerOzone chassis provides environment friendly, high efficiency cooling and heating where individual, quiet control is a priority. This application flexible unit is also a direct replacement for Remington/Singer/McQuay C/EC series built beginning in 1967 (design code C), and replaces Islandaire EC series chassis. An optional adapter kit is required when replacing original units built before 1967. Remington/Singer/McQuay C models were hydronic heat units and EC models were electric heat units. This is a modular design unit where the chassis is a part of a complete system that consists of the chassis, blower section, heat section, heat section cradle, control box, wall sleeve, and outdoor louver. The chassis contains the compressor, indoor and outdoor heat exchangers, condenser motor and fans, ventilation damper, heat damper, and refrigeration circuit controls.

The CEC chassis is dimensionally identical to the original to fit the existing sleeve and room cabinet, and works with the original blower, heater and control for a fast, easy, and trouble-free chassis change out. When blower, heater, or control box is to be replaced, you must order the complete Adirondack-Aire Replacement Modules Package.

Quality components, careful design and testing and the latest in environment friendly technology mean long unit life, user satisfaction, and lower energy costs. The Adirondack-Aire CEC is built with an extensive list of standard features that includes: Rust-Block* corrosion protection system, centrifugal condenser fans, thermostatic expansion valve, refrigerant circuit access ports, evaporator freeze protection, anti-short cycle, motorized vent and heat dampers with manual shut-off, permanent electrostatic air filter, chassis lift handles, and high pressure over protection.

Cold Point Corp. backs the CEC with a customer friendly one-year parts and labor warranty and five year compressor warranty, (see Warranty document for details).* Rust-Block corrosion protection system consists of: Heavy gauge galvanized steel construction with powder paint finished condenser and evaporator pans; galvanized or

aluminum condenser fan, stainless steel compressor and condenser motor studs; Magnaguard and/or stainless steel screws and fasteners.

• Made in the USA

• Heavy-Duty construction. Dimensionally identical to original Singer/McQuay chassis.

• Exclusive Rust-Block corrosion protection

• High efficiency PSC fan motors with built-in temperature protection

• UL listed components and construction

• Quiet, durable, and efficient compressor with built-in pressure and temperature protection

• Heavy gauge G60 galvanized steel construction with powder coat painted condenser and evaporator pans

• Motorized vent and heat dampers with manual shut-off

• Anti-short cycle

• High efficiency copper tube-aluminum fin evaporator and condenser coils

• Centrifugal condenser fans for proven airflow performance

• Condensate re-evaporation

• High pressure switch with manual reset

• Frost free low ambient cooling

• Electrostatic air filter

• Chassis lift handles facilitate easy chassis removal and handling

• Thermostatic expansion valve

• Precision charged with zerOzone R-410A refrigerant

Standard Features:

Electrical Data

ModelCompressor

Type Voltage

Volt-Hz-Ph

Evaporator Motor (2)

Condenser Motor Compressor Cooling

Total Amps

Ckt Amps

Max Fuse*

Min Volts

FLA HP Amps HP RLA LRA

CEC-25 Recip. 208-230/60/1 .35 ea/ .70 1/20 3.6 1/2 9.4 54.0 13.7 16 25 197

CEC-25 Recip. 277/60/1 .30 ea/ .60 1/20 2.7 1/2 8.0 46.0 11.3 13 20 240

CEC-30 Recip. 208-230/60/1 .35 ea/ .70 1/20 3.6 1/2 11.6 74.0 15.9 19 30 197

CEC-30 Recip. 277/60/1 .30 ea/ .60 1/20 2.7 1/2 9.9 67.0 13.7 16 25 240

* Electric heater may change branch CKT Ampacity and Fuse Size. Refer to electric heat specifications for details.

Replaces Singer / McQuay C/EC and IslandAire EC

Page 3: Series CEC - Cold Point Corporation AIRE Series CEC Singer / McQuay C/EC and IslandAire EC Application Flexible Fast and Easy Replacement Damage Protection

Fast and Easy ReplacementThe Adirondack-Aire CEC series replacement chassis fits the existing Singer/McQuay wall sleeves and room cabinets without modification. Because the chassis dimensions and construction details are like the original, replacement work is fast and easy. Using Adirondack-Aire replacements eliminates the need for room and exterior wall renovation and is the solution that gets your property back in service quickly and at the lowest total cost. Choose the optional room cabinet to give the unit a brand new look and improve room aesthetics.

Damage ProtectionA premium feature usually found only in expensive commercial systems, the standard high-pressure switch and evaporator freeze protection stop unit operation before damage occurs, should airflow become reduced or obstructed due to dirty coils, obstructed airflow, or motor failure or lock up. A slinger axial condenser fan and draw-thru airflow pattern re-evaporates condensate and makes cleaning dirty coils easy. Condensate re-evaporation and the Rust-Block system assure a stain-free building exterior.

Options and Accessories• Replacement modules package (see

price page for details)• Design code ‘A’ adapter kit• Design code ‘B’ adapter kit (consult

factory)• Electric or hydronic heat• Heat cradle• Room cabinet• Wall sleeves (consult factory• Louvers (consult factory)• 265/277V

CEC SERIES CHASSIS APPLICATION & BENEFITS

Unit Sizes

ModelA B C D E F G Chassis

Weight (lbs)Inches

CEC-25 21 1/4 14 1/4 15 12 1/4 40 1/4 52 1/8 22 1/4 300

CEC-30 21 1/4 14 1/4 15 12 1/4 40 1/4 52 1/8 22 1/4 325

Performance Ratings*Model Cool Btuh Sens Btuh EER Evap CFM Vent CFM Cond. Fan Type Refrigerant

CEC-25 21,000 16,100 7.2 730 165 Centrifugal Blowers

R-410A

CEC-30 25,000 17,400 7.0 710 210 R-410A

Continuous engineering improvements may result in performance changes without notice.* Rated in accordance with ARI

A

B

C

D

E

F

G

Electrical Heat Ratings (Optional)Heater

No. Volt Watts Btuh* HTR Amps Amp Fuse

SizeCEC

Model

4.8

208 3,925 13,385 18.9 26 25

25 & 30230 4,800 16,370 20.9 28 25

277 4,800 16,370 17.4 24 25

7.2

208 5,890 20,085 28.3 37 35

25 & 30230 7,200 24,550 31.3 41 40

277 7,200 24,550 26.0 35 35

9.6

208 7,850 26,772 37.8 49 45

30 Only230 9,600 32,736 41.8 54 50

277 9,600 32,736 34.7 45 45

* Does not include fan heat contribution

Hydronic Coil Performance RatingsModel No. CFM Water Temp/

Steam PSI Btuh

25 550200° Water 21,100

5 PSI Steam 28,400

30 700200° Water 23,300

5 PSI Steam 31,200

NEMA ConfigurationsNon Locking Plugs/Receptacles

Voltage 125V 250V 277V

15A Recp.

15A Plug

20A Recp.

20A Plug

30A Recp.

30A Plug

Page 4: Series CEC - Cold Point Corporation AIRE Series CEC Singer / McQuay C/EC and IslandAire EC Application Flexible Fast and Easy Replacement Damage Protection

rev. 08-17 CPL024

7500 Cold Point Dr • Rome, New York 13440Phone (315) 339-2331 • Fax (315) 339-2358www.ColdPointCorp.com©2017 Cold Point Corp. All rights reserved.

Cold Point equipment has been specified in hundreds of projects in these and other applications:Direct Replacement | New Construction | Renovation | Commercial & Residential Solutions

INNOVATIVE HEATING AND COOLING SOLUTIONS

Your Cold Point Representative:

Cold Point values reliability as much as youYour Cold Point sales representative knows their reputation is on the line with every sale. Therefore, they are as

personally invested in your comfort as you are, and take great pride in creating your perfect indoor environment.

Rest comfortably, knowing Cold Point stands behind our productsThe Cold Point Corporation backs our products with a standard warranty that includes labor for the entire first year

of ownership. Registered Limited Warranty terms include: 12 month limited warranty on components, 60 month limited warranty on all unit compressors from the date of original installation OR 15 months limited warranty on components, 63 month limited warranty on all unit compressors from the date of original sale, whichever comes first. For all coverage options and complete coverage terms, check with your local Cold Point representative for full details.

Industry-leading expertiseCold Point Corporation is the industry-leading supplier of aftermarket comfort solutions for commercial and residential

applications. We have over 18 years of experience developing OEM-style replacement products to keep you happy and comfortable. Whether it is a water source heat pump application or an air source PTAC system, Cold Point has the knowledge and products to restore your system to its original operating condition.

Reliable comfort products backed by the industry experts in OEM-style replacement unitsTo learn more about how the Cold Point Corporation can help you save time and money on your next project,

contact your local Cold Point representative. Call 315-339-2331 to speak with one of our specialists, or e-mail your request to [email protected].