Copyright 1997-2005, by ODIS Irrigation Equipment LTD. All rights reserved. 4th ed. 12/05
Aimed at continued improvements, ODIS reserves the right to change specifications without prior notice. 1
E
HYDRO-CYCLONE / SAND SEPARATORS Series 5000 GENERAL INSTRUCTIONS
This hydro-cyclone has been designed and manufactured to achieve the highest standards of quality and finish. The ODIS hydro-cyclone separator is a simple device, easy to operate and maintain. It has no moving parts or screens. The hydro-cyclone separates sand and other solid matter with a very little head loss at 90% efficiency and may reach a higher rate of efficiency. There is no head loss build up and no clogging by the solids that are being separated. Its versatility in system configuration and its economy in installation are some of its great advantages. For best results, the hydro-cyclone must be installed, operated and maintained according to the following instructions.
INSTALLATION
Install and connect the hydro-cyclone vertically with the underflow chamber underneath the hydro-cyclone.
Special attention must be given to the correct flow direction: horizontal inlet and top vertical outlet are marked by arrows
If the hydro-cyclone is equipped with an automatic flushing system: 1) A double chamber hydraulic drain valve must be installed at the drain point (5). 2) Connect the controller to the valve. 3) Insert the batteries inside the controller and close its cover tightly. 4) Adjust the controller as follows:
a) Flushing time for underflow chambers 5 60 liters: 15 20 seconds. b) Flushing time for underflow chambers 120 300 liters: 30 50 seconds. c) Time between flushings: 30 120 minutes.
If the water contains a high load of dirt, shorten the time between the flushings.
Check that the actual flow-rate through the hydro-cyclone is within the recommended rate. Inadequate flow-rate will result in reduced performance.
Copyright 1997-2005, by ODIS Irrigation Equipment LTD. All rights reserved. 4th ed. 12/05
Aimed at continued improvements, ODIS reserves the right to change specifications without prior notice. 2
E
If more than one hydro-cyclone is installed, leave sufficient space between the units to facilitate the maintenance.
Specially designed ODIS manifolds (series 9000) are available for mounting multiple filter arrays. If the pressure is not controlled effectively and might rise above 8 bar (120 psi) a
pressure relief valve must be installed before the filtering installation.
OPERATION
Maximal operational pressure should not exceed 8 bar (120 psi). The hydro-cyclone is designed to withstand a maximum pressure of 10 bar (150 psi). Normal working conditions are achieved when head-loss on the hydro-cyclone is not less than
0.2 bar (3 psi).
Recommended head loss: 0.2 0.5 bar (3 8 psi). A head-loss of more than 0.5 bar (8 psi) might induce increased erosion. A head-loss of less than 0.2 bar (3 psi) will reduce the separation efficiency. As a rule, the separation improves as the hydro-cyclone diameter decreases and the pressure
loss increases.
Warning: Do not tighten or open the cover during operation or under pressure.
ILLUSTRATED PARTS BREAKDOWN
Underflow Chamber Models 590060, 590120, 590220, 590300
Copyright 1997-2005, by ODIS Irrigation Equipment LTD. All rights reserved. 4th ed. 12/05
Aimed at continued improvements, ODIS reserves the right to change specifications without prior notice. 3
E
Catalog Numbers Underflow Chambers
Models 590002 590005 590010 590060 590120 590220 590320
Capacity (liter) 2 5 10 60 120 220 320
Capacity (U.S. gal)
0.5 1.3 2.6 16 32 58 85
No Description - - - - - - -
1 Handle E000101 E000100 E000100 - - - -
2 Tightening Bracket
E000214 E000216 E000216 - - - -
3 Cover E000240 E000260 E000260 E400260 E400260 E400260 E400260
4 Neoprene Cover gasket
E001340 E001361 E001361 E004365 E004365 E004365 E004365
5 Male plug H070305 ()
H070310 (1)
H070310 (1)
H070320 (2)
- - -
6 Underflow Chamber body
A590002 A590005 A590010 A590060 A590120 A590220 A590300
9 Rubber insert
- - E545950 E550952 E550952 E550952 E560952
Catalog Numbers Hydrocyclones
Model Part No.
Description 50307(3/4) 50410 (1) 50615 (11/2) 50820 (2) 50830 (3)
9 Rubber insert
- - E545950 E545950 E545950
10 Steel Insert - - - - -
11 Male Plug - - H070305 (1/2) H070305 (
1/2) H070305 (
1/2)
12 Body A50307 A50410 A50615 A50820 A50830
Model Part No.
Description 51243 (4x3) 51640 (4) 52060 (6) 52460 (6) 53080 (8)
9 Rubber Insert
E545 952 E550 952 E560 952 E560 952 E560 952
10 Steel Insert - - - - -
11 Male Plug H070305 (1/2) H070305 (
1/2) H070305 (
1/2) H070305 (
1/2) H070305 (
1/2)
12 Body A51243 A51640 A52060 A52460 A53080
When ordering hydro-cyclone body, please specify end connections: Thread (M)/ Flange (F)/ Victaulic (V).
Copyright 1997-2005, by ODIS Irrigation Equipment LTD. All rights reserved. 4th ed. 12/05
Aimed at continued improvements, ODIS reserves the right to change specifications without prior notice. 4
E
UNDERFLOW CHAMBER MANUAL FLUSHING
The underflow chamber is flushed automatically with an irrigation controller or a computer at periodic intervals (in filtration arrays, or automatic drainage system).
When a manual valve is installed, drain the underflow chamber at periodic intervals according to the recommendations.
The underflow chamber should be drained when it reaches about its 1/3 full. Do not let the underflow chamber fill-up more than of its volume. PERIODIC CLEANING OF THE UNDERFLOW CHAMBER Periodic cleaning of the Underflow Chamber should be performed once a month. Close the hydro-cyclones inlet valve. Open drain valve (5) to release pressure and drain the underflow chamber. Release the handle (1) the tightening bracket (2) and remove the cover (3). Remove all the sediments collected in the underflow chamber. Rinse thoroughly the inside of the empty underflow chamber. Check that the insert is not damaged, replace if necessary. Place the cover (3) of the underflow chamber, so that the covers gasket (4) fits over it. Mount properly the tightening bracket (2) and the handle (1).
MAINTENANCE Each hydro-cyclone is supplied with instructions for maintenance, installation and operation. Apply a layer of grease to the handles (1) thread, once a year. Any damage to the protective coating must be repaired without delay. Prior to the application
of the protective paint, clean thoroughly the damaged area with a wire brush.
Recommended Flow-Rates
Inlet / Outlet Diameters
Recommended Flow-Rate
Standard Underflow Chamber
Models
inch mm m3/h U.S. gpm liters
U.S. gallons
50307 20 2 - 3.5 8.8 - 15 2 0.5
50410 1 25 3.5 - 7.5 15 - 33 2 0.5
50615 11/2 40 7.5 - 12 33 - 53 10 2.6
50820 2 50 11 - 17 48 - 75 10 2.6
50830 3 80 18 - 34 79 - 150 10 2.6
51243 4in/ 3out 100in/80out 35 - 52 154 - 229 60 16
51640 4 100 52 - 82 229 - 361 120 32
52060 6 150 98 - 160 431 - 704 220 58
52460 6 150 140 - 230 616 - 1020 220 58
53080 8 200 230 - 360 1012 - 1584 320 85
NOTE: The size of the Hydro-cyclone Separator must suit the actual flow-rate in the pipe. A larger or smaller separator would not maintain the required speed of circulation, and the quality of separation would be affected.
20 Hayetsira st. P.O.B. 3137 Kiriat Arye, Petach Tikva 49130 ISRAEL Tel: 972-3-9258500, Fax: 972-3-9249023 E-mail: [email protected] Web Site: www.odis.co.il